• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 230
  • 4
  • 4
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 238
  • 132
  • 52
  • 38
  • 34
  • 27
  • 27
  • 24
  • 24
  • 24
  • 23
  • 22
  • 20
  • 18
  • 18
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
111

Avaliação da variação de pressão de pulso (VPP) frente a diferentes concentrações inaladas de isoflurano, desflurano e sevoflurano: modelo experimental em suínos / Evaluation of pulse pressure variation (PPV) using different concentrations of isoflurane, desflurane and sevoflurane: experimental model in pigs

Oshiro, Alexandre Hideaki 30 January 2013 (has links)
Introdução: Os anestésicos inalatórios empregados atualmente na prática clinica (isoflurano, sevoflurano e desflurano) possuem propriedades farmacocinéticas que favorecem rápida recuperação da anestesia, porém seu uso pode causar instabilidade hemodinâmica dose-dependente, relacionado à depressão direta da contratilidade miocárdica ou à hipovolemia relativa, derivado de um sequestro de sangue devido à vasodilatação do leito vascular periférico. Este estudo visa avaliar o comportamento da VPP durante a anestesia inalatória. Para tanto se utilizou três diferentes agentes inalatórios (isoflurano, sevoflurano e desflurano) em diferentes concentrações inaladas. Métodos: Foram utilizados 25 suínos divididos aleatoriamente em três grupos. Os animais foram submetidos à anestesia com o anestésico do respectivo grupo. Imediatamente após a determinação da CAM individual do agente inalatório em cada animal, ocorreu a primeira coleta de dados. O animal foi, então, exposto a diferentes níveis de CAM (1,0 CAM; 1,25 CAM) seguido por uma exposição decrescente de CAM (1,0 CAM); provocou-se então uma hemorragia correspondente a 30% da volemia e exposição a dois níveis de CAM (1,0 e 1,25), com 20 minutos em cada exposição. Ao final de cada período os valores ecocardiográficos e do VPP foram mensurados. A análise estatística foi realizada através de provas paramétricas empregando-se o método de comparações múltiplas para análise de variância com medidas repetidas (ANOVA). O grau de significância foi de 5% (p < 0,05). Resultados: Há aumento na variação de pressão de pulso com incremento de 25% na CAM dos anestésicos inalatórios (de 8±1 para 11±3% no grupo DESF, de 7±2 para 9±2 no grupo SEVO e de 9±4 para 10±3% no grupo ISO) sem diferença estatística entre os anestésicos. Apesar deste aumento na CAM e significativa hipotensão e queda no débito cardíaco, o aumento na VPP não torna o paciente responsivo a infusão de fluidos (o VPP permaneceu abaixo de 13%). Há pequena queda na PAM quando se eleva a CAM dos anestésicos em 25%, porém só há queda estatisticamente significativa no grupo DESF (de 84±7 para 68±12 mmHg). Não foram observadas alterações importantes em relação à contratilidade miocárdica. Conclusão: Observou-se que a VPP não é influenciada como o uso dos diferentes anestésicos inalatórios e apesar dos efeitos cardiovasculares esperados destes agentes, mantem-se a capacidade de demonstrar alterações de pré-carga mesmo em concentrações correspondentes a 1,25 CAM / Background: Inhalant anesthetics, such as isoflurane, sevoflurane and desflurane are widely used in daily clinical practice due to its pharmacological properties allowing a rapid recovery from anesthesia. Nevertheless, its use can lead to dose-dependent hemodynamic instability related to direct depression in myocardial contractility or to a relative hypovolemia caused by vasodilation of peripheral capillary bed. This study aims to evaluate the behavior of PPV during inhalant anesthesia. For this, three different anesthetics were used (isoflurane, sevoflurane and desflurane) with different inhaled concentrations. Methods: 25 young pigs were randomly assigned into three groups. Animals were anesthetized with its correspondent agent according to its group. After individual determination of minimal alveolar concentration (MAC), first data collection occurred. Pigs were then exposed to different MAC (1MAC and 1,25 MAC) followed by a decrease in MAC (1 MAC). At this point a 30% of estimated volemia hemorrhage was caused and pigs were exposed to a period of 1 MAC and after that 1,25 MAC. Each period lasted 20 minutes. At the end of each period, hemodynamic parameters and echocardiography were collected. Data were submitted to analysis of variance for repeated measures (ANOVA). P<0,05 was considered statistically significant. Results: There was an increase in PPV when with 1,25 MAC of all anesthetics. (from 8±1 to 11±3% in group DESF, from 7±2 to 9±2 in group SEVO and from 9±4 to 10±3% in group ISO), but without statistical difference among groups. Although there was an increase in PPV, followed by hypotension and drop in cardiac index, patients werent fluid responsive with a 25% increase in MAC, since PPV was lower than 13%. The decrease in blood pressure followed by 1,25MAC was only significant in DESF group (from 84±7 to 68±12 mmHg). No important alterations related to myocardial contractility were observed. Conclusion: PPV is not influenced by the use of different inhalant anesthetics and although there are cardiovascular effects of these agents which are expected, and were able to demonstrate alterations in preload even in concentration of 1,25 MAC
112

Determinação da variação da pressão de pulso em cadelas mecanicamente ventiladas com e sem PEEP, submetidas à expansão volêmica durante cirurgia abdominal / Assessment of arterial pulse pressure variation in mechanically ventilated dogs with PEEP and ZEEP, submitted to volume load during abdominal surgery

Moreno, Luciana Montel Moreno 12 December 2008 (has links)
Ao contrário dos indicadores estáticos, como a pressão venosa central e a pressão de oclusão da artéria pulmonar, a variação da pressão de pulso arterial tem se mostrado um indicador hemodinâmico preciso para a determinação da responsividade à administração de fluido. Objetivo: Este estudo objetivou mensurar a variação da pressão de pulso em cadelas mecanicamente ventiladas submetidas a expansão volêmica durante procedimento cirúrgico eletivo (ovário-salpingo-histerectomia) e determinar a relação deste indicador com os dados hemodinâmicos obtidos por meio do exame ecodopplercardiográfico transesofágico. Material e método: Quinze cadelas foram distribuídas aleatoriamente em dois grupos: sem pressão positiva ao final da expiração (GI - ZEEP, n = 7) e com pressão positiva ao final da expiração de 5cmH2O (GII - PEEP, n = 8). As avaliações hemodinâmicas incluindo freqüência cardíaca (FC), pressão arterial média invasiva (PaM), variação da pressão de pulso (VPP), pressão venosa central (PVC), volume sistólico (VE), índice cardíaco (IC), velocidade do fluxo aórtico (VFA) e gradiente de pressão do fluxo aórtico (Grad); análise de gases sangüíneos e parâmetros do sistema respiratório incluindo freqüência respiratória (FR) e pressão de pico inspiratória (PIP), foram mensuradas antes da aplicação da PEEP em cadelas do GII (M0); imediatamente antes (M1) e cinco minutos após (M2) a expansão volêmica com 10ml/Kg de solução de Ringer Lactato. Os grupos e tempos foram comparados por meio da análise de variância (ANOVA) seguida do teste de Tukey, com nível de significância de 5%. Resultados: A utilização da PEEP ocasionou um significante aumento dos seguintes parâmetros: VPP (M0 - 9.5 ± 2.92 vs M1 - 12.1 ± 2.19, P < 0.05); PVC ( 4.9 ± 2.47 vs 6.5 ± 2.73, P < 0.05); PIP (9.9 ± 1.36 vs 13.0 ± 2.2, P < 0.05) e PaO2 (336.5 ± 64.04 vs 373.6 ± 97.82, P < 0.05). Os animais do GI apresentaram um significante aumento dos seguintes parâmetros depois da expansão volêmica: VE (25.4 ± 3.92 vs 19.1 ± 3.22, P < 0.05), IC (3.8 ± 0.99 vs 2.4 ± 0.47, P < 0.05), VFA (93.8 ± 17.60 vs 74.5 ± 14.66, P < 0.05) e Grad (3.6 ± 1.30 vs 2.3 ± 0.92, P < 0.05). Alterações significativas também foram observadas nos seguintes parâmetros do GII depois da expansão volêmica: PaM (108.6 ± 20.6 vs 96.9 ± 19.97, P < 0.05), VPP (5.2 ± 1.8 vs 12.1 ± 2.19, P < 0.05), VE (26.6 ± 8.18 vs 20 ± 5.15, P < 0.05), IC (3.6 ± 0.90 vs 2.4 ± 0.56, P < 0.05), VFA (97.6 ± 25.49 vs 83.6 ± 24.12, P < 0.05) e Grad (4.0 ± 2.01 vs 3.0 ± 1.64, P < 0.05). Quando comparado M1 do GI e do GII, diferença significativa foi observada com a VPP (7.1 ± 1.64 vs 12.1 ± 2.19, P < 0.05). A FR foi maior no GII quando comparada ao GI (FR GII M1 e GII M2 - 16.9 ± 1.36 vs GI M1 - 14.9 ± 1.35 e GI M2 - 15.3 ± 1.5, P < 0.05). PIP foi também maior no GII quando comparada ao GI (GII M1 - 13.0 ± 2.20 vs GI M1 - 7.3 ± 2.21; GII M2 - 13.4 ± 2.50 vs GI M2 - 7.7 ± 2.14, P < 0.05). Conclusão: Este estudo mostrou que a variação da pressão de pulso é um índice adequado para avaliar o estado hemodinâmico durante a instituição de PEEP, sendo a avaliação ecodopplercardiográfica transesofágica uma excelente técnica de monitoração do estado hemodinâmico nos pacientes submetidos a procedimento cirúrgico. / Contrary to static parameters such as central venous pressure and pulmonary capillary wedge pressure, pulse pressure variation has proven itself as an accurate hemodynamic tool for the determination of fluid responsiveness. Objective: To measure pulse pressure variation in mechanically-ventilated bitches submitted to volume load during elective surgery (ovariohysterectomy) and to determine its relationship with hemodynamic parameters obtained with transesophageal Doppler echocardiography. Material and Methods: Fifteen bitches were randomly distributed between two groups: with zero end-expiratory pressure (GI - ZEEP, n=7) and with positive end-expiratory pressure of 5cmH2O (GII - PEEP, n=8). Hemodynamic evaluations including heart rate (HR), invasive mean arterial pressure (MAP), pulse pressure variation (PPV), central venous pressure (CVP), stroke volume (SV), cardiac index (CI), aortic blood flow velocity and aortic flow pressure gradient; blood-gas analysis and ventilatory parameters including respiratory rate (RR) and peak inspiratory pressure (PIP), were measured before employment of PEEP in bitches from GII (M0); immediately before (M1) and five minutes after (M2) volume expansion using 10ml/Kg lacted Ringers solution. Statistical analysis was based on ANOVA for repeated measures followed by Turkeys t-test with significance level of 0.05. Results: The use of PEEP induced a significant increase in the following parameters: PPV (M0 - 9.5 ± 2.92 vs M1 - 12.1 ± 2.19, P < 0.05); CVP ( 4.9 ± 2.47 vs 6.5 ± 2.73, P < 0.05); PIP (9.9 ± 1.36 vs 13.0 ± 2.2, P < 0.05) and PaO2 (336.5 ± 64.04 vs 373.6 ± 97.82, P < 0.05). Animals in GI presented a significant increase in the following parameters after fluid load: SV (25.4 ± 3.92 vs 19.1 ± 3.22, P < 0.05), CI (3.8 ± 0.99 vs 2.4 ± 0.47, P < 0.05), aortic blood flow velocity (93.8 ± 17.60 vs 74.5 ± 14.66, P < 0.05) and aortic flow pressure gradient (3.6 ± 1.30 vs 2.3 ± 0.92, P < 0.05). Statistical significance of the following parameters were observed in GII after fluid load: MAP (108.6 ± 20.6 vs 96.9 ± 19.97, P < 0.05), PPV (5.2 ± 1.8 vs 12.1 ± 2.19, P < 0.05), SV (26.6 ± 8.18 vs 20 ± 5.15, P < 0.05), CI (3.6 ± 0.90 vs 2.4 ± 0.56, P < 0.05), aortic blood flow velocity (97.6 ± 25.49 vs 83.6 ± 24.12, P < 0.05) and aortic flow pressure gradient (4.0 ± 2.01 vs 3.0 ± 1.64, P < 0.05). When comparing M1 of GI and GII, a statistical significant difference was observed with PPV (7.1 ± 1.64 vs 12.1 ± 2.19, P < 0.05). Respiratory rate was greater in GII than in GI (RR GII M1 and GII M2 - 16.9 ± 1.36 vs GI M1 - 14.9 ± 1.35 and GI M2 - 15.3 ± 1.5, P < 0.05). Peak inspiratory pressure was also greater in GII than in GI (GII M1 - 13.0 ± 2.20 vs GI M1 - 7.3 ± 2.21; GII M2 - 13.4 ± 2.50 vs GI M2 - 7.7 ± 2.14, P < 0.05). Conclusion: This study showed that the pulse pressure variation is an adequate indicator to evaluate the hemodynamic status during PEEP application, being the transesophageal Doppler echocardiography evaluation a great tool in monitoring the hemodynamic status in patients undergoing surgery.
113

Avaliação da variação de pressão de pulso (VPP) frente a diferentes concentrações inaladas de isoflurano, desflurano e sevoflurano: modelo experimental em suínos / Evaluation of pulse pressure variation (PPV) using different concentrations of isoflurane, desflurane and sevoflurane: experimental model in pigs

Alexandre Hideaki Oshiro 30 January 2013 (has links)
Introdução: Os anestésicos inalatórios empregados atualmente na prática clinica (isoflurano, sevoflurano e desflurano) possuem propriedades farmacocinéticas que favorecem rápida recuperação da anestesia, porém seu uso pode causar instabilidade hemodinâmica dose-dependente, relacionado à depressão direta da contratilidade miocárdica ou à hipovolemia relativa, derivado de um sequestro de sangue devido à vasodilatação do leito vascular periférico. Este estudo visa avaliar o comportamento da VPP durante a anestesia inalatória. Para tanto se utilizou três diferentes agentes inalatórios (isoflurano, sevoflurano e desflurano) em diferentes concentrações inaladas. Métodos: Foram utilizados 25 suínos divididos aleatoriamente em três grupos. Os animais foram submetidos à anestesia com o anestésico do respectivo grupo. Imediatamente após a determinação da CAM individual do agente inalatório em cada animal, ocorreu a primeira coleta de dados. O animal foi, então, exposto a diferentes níveis de CAM (1,0 CAM; 1,25 CAM) seguido por uma exposição decrescente de CAM (1,0 CAM); provocou-se então uma hemorragia correspondente a 30% da volemia e exposição a dois níveis de CAM (1,0 e 1,25), com 20 minutos em cada exposição. Ao final de cada período os valores ecocardiográficos e do VPP foram mensurados. A análise estatística foi realizada através de provas paramétricas empregando-se o método de comparações múltiplas para análise de variância com medidas repetidas (ANOVA). O grau de significância foi de 5% (p < 0,05). Resultados: Há aumento na variação de pressão de pulso com incremento de 25% na CAM dos anestésicos inalatórios (de 8±1 para 11±3% no grupo DESF, de 7±2 para 9±2 no grupo SEVO e de 9±4 para 10±3% no grupo ISO) sem diferença estatística entre os anestésicos. Apesar deste aumento na CAM e significativa hipotensão e queda no débito cardíaco, o aumento na VPP não torna o paciente responsivo a infusão de fluidos (o VPP permaneceu abaixo de 13%). Há pequena queda na PAM quando se eleva a CAM dos anestésicos em 25%, porém só há queda estatisticamente significativa no grupo DESF (de 84±7 para 68±12 mmHg). Não foram observadas alterações importantes em relação à contratilidade miocárdica. Conclusão: Observou-se que a VPP não é influenciada como o uso dos diferentes anestésicos inalatórios e apesar dos efeitos cardiovasculares esperados destes agentes, mantem-se a capacidade de demonstrar alterações de pré-carga mesmo em concentrações correspondentes a 1,25 CAM / Background: Inhalant anesthetics, such as isoflurane, sevoflurane and desflurane are widely used in daily clinical practice due to its pharmacological properties allowing a rapid recovery from anesthesia. Nevertheless, its use can lead to dose-dependent hemodynamic instability related to direct depression in myocardial contractility or to a relative hypovolemia caused by vasodilation of peripheral capillary bed. This study aims to evaluate the behavior of PPV during inhalant anesthesia. For this, three different anesthetics were used (isoflurane, sevoflurane and desflurane) with different inhaled concentrations. Methods: 25 young pigs were randomly assigned into three groups. Animals were anesthetized with its correspondent agent according to its group. After individual determination of minimal alveolar concentration (MAC), first data collection occurred. Pigs were then exposed to different MAC (1MAC and 1,25 MAC) followed by a decrease in MAC (1 MAC). At this point a 30% of estimated volemia hemorrhage was caused and pigs were exposed to a period of 1 MAC and after that 1,25 MAC. Each period lasted 20 minutes. At the end of each period, hemodynamic parameters and echocardiography were collected. Data were submitted to analysis of variance for repeated measures (ANOVA). P<0,05 was considered statistically significant. Results: There was an increase in PPV when with 1,25 MAC of all anesthetics. (from 8±1 to 11±3% in group DESF, from 7±2 to 9±2 in group SEVO and from 9±4 to 10±3% in group ISO), but without statistical difference among groups. Although there was an increase in PPV, followed by hypotension and drop in cardiac index, patients werent fluid responsive with a 25% increase in MAC, since PPV was lower than 13%. The decrease in blood pressure followed by 1,25MAC was only significant in DESF group (from 84±7 to 68±12 mmHg). No important alterations related to myocardial contractility were observed. Conclusion: PPV is not influenced by the use of different inhalant anesthetics and although there are cardiovascular effects of these agents which are expected, and were able to demonstrate alterations in preload even in concentration of 1,25 MAC
114

AVALIAÇÃO DOS PARÂMETROS DE MEDIDA CENTRAL DA PRESSÃO ARTERIAL DE PARTICIPANTES DA CAMINHADA ECOLÓGICA DE GOIÁS. / Assessment of central measurement parameters blood pressure athletes of Goiás ecological walk.

Pereira, Edison Nunes 11 August 2015 (has links)
Made available in DSpace on 2016-08-10T10:57:43Z (GMT). No. of bitstreams: 1 Edison Nunes Pereira.pdf: 2680988 bytes, checksum: 2c09ac181f36ff093474c57fcd59da95 (MD5) Previous issue date: 2015-08-11 / In Goiás, the Ecological walk takes place annually and is an unique event for its distance (310km) and dynamics of performance (average of 62km-day for 5 days, average speed 7.6Km-h). Although the beneficial effects of moderate exercise are well known, the effects of intense exercise with long duration, as the Ecological walk, have not been well studied. This study aimed to verify the effects of prolonged exercise in central blood pressure and the correlation of these parameters with age. A total of 25 men were included in the study. The central blood pressure was measure datbaseline (A0), on the 2nd (A2), 3rd (A3) and 4th (A4) days of walk after the daily stop for night rest. The following parameters were measured: peripheral and central systolic and diastolic blood pressure, peripheral and central pulse pressure, pulse pressure amplified, 75% augmentation index, pulse wave velocity and vascular resistance. An oscillometric device from Mobil The Graphi® (IEM Stolber, Germany) was used. To compare the parameters between the daily measurements we used ANOVA for repeated measures followed by Bonferrroni post hoc and Pearson test for correlation. We considered significant p<0.05. We assessed 25 athletes with mean age 45.3±9.1.Central systolic blood pressure, reduced from A0 (113.8±2.1mmHg) to A3 (105.7±1.6mmHg) (p=0.035) and increased from A3 (105.7±1.6mmHg) to A4 (111.5±1.6mmHg) (p=0.006). The central diastolic blood pressure reduced from A0 (80.3±1.9mmHg) to A3 (74.3±1.5mmHg) (p=0.018)and A2 (78.6±1) to A3 (74.3±1.5mmHg) (p=0.036) and increased from A3 (74.3±1.5mmHg) for A4 (78.6±1.7mmHg) (p=0.014). The peripheral systemic blood pressure decreased from A0 (127.9±2.6 mmHg) to A2 (115.6±1.9mmHg) (p=0.002); to A3 (115.6±1.7mmHg) (p=0.003) and A4 (118.6±1.5mmHg) (p=0.007). The peripheral diastolic blood pressure reduced from A0 (78.7±1.9mmHg); from A3 (73.0±1.4mmHg) (p=0.018); A2 (77.4±1.1mmHg) to A3 (73.00±1.4mmHg) (p=0.040); and increased from A3 (73.0±1.4mmHg) to A4 (77.4±1.6mmHg) (p=0.010). The variables correlated with age were the central systemic blood pressure (A0), Peripheral pulse pressure (A3) and pulse wave velocity. Blood pressure decreased in the early days of walking, returning close to baseline at the end of the competition. Pulse wave velocity was strongly correlated with age. / Em Goiás, a caminhada Ecológica ocorre anualmente e é um evento único por sua distância (310 km) e dinâmica de realização (média de 62km-dia em 5 dias, média de 7,6 km-h). Apesar de os efeitos benéficos do exercício moderado serem bem conhecidos, os resultados de exercícios intensos e de longa duração, como a Caminhada Ecológica, ainda não foram muito estudados. O presente estudo teve o objetivo de verificar os efeitos do exercício físico prolongado nos parâmetros da medida central da pressão arterial e correlacionar esses parâmetros com a idade. Participaram do estudo 25 homens. Foi efetuada a medida central da pressão arterial para avaliar a participação (A0), nos 2º (A2), 3º (A3) e 4º (A4) dias de caminhada, após a parada diária para descanso noturno. Com essa medida foram obtidos os seguintes parâmetros: pressão arterial sistólica e diastólica periférica e central, pressão de pulso periférica e central, pressão de pulso amplificada, augmentation índex 75%, velocidade de onda de pulso e resistência vascular. Foi utilizado o dispositivo oscilométrico Mobil O Graphi® (IEM, Stolber, Alemanha). Para a comparação dos parâmetros entre os dias avaliados, foi usada a ANOVA para medidas repetidas, seguida de post hoc de Bonferrroni e para a correlação foi aplicado o teste de Pearson. Considerou-se como significativo p<0,05. Foram considerados 25 atletas com idade média de 45,3±9,1 anos. A medida central da pressão arterial sistólica reduziu de A0 (113,8±2,1mmHg) para A3 (105,7±1,6mmHg) (p=0,035) e aumentou de A3 (105,7±1,6mmHg) para A4 (111,5±1,6mmHg) (p=0,006). A medida central da pressão arterial diastólica diminuiu de A0 (80,3±1,9 mmHg) para A3 (74,2±1,0mmHg)(p=0,018) e A2 (78,2±1,9) para A3 (74,3±1,5mmHg) (p=0,036) e aumentou da A3 (74,3±1,5mmHg) para A4 (78,6±1,7mmHg) (p=0,014). A medida da pressão arterial sistólica periférica apresentou redução de A0 (127,9±2,6mmHg) para A2 (115,6±1,9mmHg) (p=0,002) para A3 (115,6±1,7mmHg) (p=0,003) e para A4 (118,6±1,5mmHg) (p=0,007). A medida periférica da pressão arterial diastólica reduziu de A0 (78,7±1,9mmHg) para A3 (73,0±1,4mmHg) (p=0,018); de A2 (77,4±1,1mmHg) para A3 (73,00±1,4mmHg) (p=0,040) e aumentou de A3 (73,0±1,4mmHg) para A4 (77,4±1,6mmHg) (p=0,010). As variáveis que apresentaram correlação com a idade foram a pressão arterial sistólica central (A0), a pressão de pulso periférica (A3) e a velocidade de onda de pulso. A pressão arterial teve queda nos primeiros dias de caminhada, retornando próxima aos valores basais no final do percurso. A velocidade de onda de pulso correlacionou-se fortemente com a idade.
115

Síntese digital direta de sinais aplicada ao acionamento de máquinas elétricas

Maurício da Graça Botelho 01 November 1996 (has links)
Neste trabalho propomos a aplicação da síntese digital direta coerente ao acionamento de máquinas elétricas de corrente alternada (CA). Inicialmente são apresentadas as técnicas mais comumente utilizadas na implementação de moduladores de largura de pulso (PWMs) para o acionamento de máquinas CA. Mostramos, para as diferentes técnicas, os efeitos na composição harmônica do sinal PWM obtido e concluímos que a técnica PWM otimizada apresenta o melhor desempenho. Apresentamos então nossa proposta para implementação de moduladores PWM através da síntese digital direta coerente, discutindo preliminarmente as técnicas mais comuns de síntese digital de sinais. A viabilidade técnica de nossa proposta é demonstrada com a implementação de um modulador PWM otimizado, destinado ao acionamento de um motor CA trifásico. Os resultados experimentais de nossa implementação são então comparados com os de previsões teóricas e simulações, verificando-se um desempenho do sistema e uma comparação favorável com outros implementados com técnicas convencionais.
116

Avaliação de desempenho de um sistema de comunicação digital com espalhamento espectral em um canal com ruído intencional

Guilherme Buzato Talhate 25 March 2011 (has links)
Neste trabalho, é proposta a avaliação de desempenho de um sistema de comunicação operando em um enlace de dados entre aeronave e uma estação em solo. Ele é baseado no padrão DVB-H (Digital Video Broadcasting - Handheld) com adaptações. O enlace deve permitir alta taxa de transmissão, oferecendo confiabilidade e robustez. Aplica-se ao sistema uma técnica de FHSS (Frequency Hopping Spread Spectrum ou espalhamento espectral por saltos em frequência) para proteção contra interferência intencional e recepção indevida. Diversas configurações de espalhamento espectral, modulação e codificação de canal são modeladas e testadas. O sistema é testado sob canal AWGN (Additive White Gaussian Noise ou ruído branco gaussiano aditivo), interferência de banda estreita, interferência tonal e interferência pulsada. O desempenho do sistema, em valores de BER (Bit Error Rate, taxa de erro de bit), simulado em diferentes cenários, é usado para avaliar a proteção contra as interferências. Os resultados da simulação, de um modo geral, concordam com os efeitos esperados. O sistema DVB-H em si já possui boa proteção contra interferência tonal e a aplicação da técnica de espalhamento espectral usada consegue fornecer uma boa proteção contra interferência pulsada. A interferência de banda estreita é capaz de degradar mais severamente o desempenho e o ganho conseguido pelas medidas de proteção é menor neste caso, porém com ganhos ainda bastante significativos. As melhorias são propostas baseadas nas fraquezas do sistema sob os cenários de interferência simulados.
117

Efeitos da não-linearidade de moduladores eletro-ópticos em enlaces fotônicos empregados na geração e na transmissão de sinais radar

Romildo Henrique de Souza 23 April 2015 (has links)
Esta dissertação realiza um estudo acerca dos efeitos decorrentes da não-linearidade da curva característica de moduladores eletro-ópticos Mach-Zehnder em enlaces fotônicos empregados em sistemas radar, visando duas aplicações: transmissão de formas de onda de sinais radar com modulação intrapulso; e geração de portadoras para sinais radar na faixa de micro-ondas e de ondas milimétricas por meio de sistemas multiplicadores de frequência. A promissora área de RF em Fotônica tem possibilitado a expansão das capacidades de sistemas de telecomunicações e sistemas de processamento de sinais em caráter dual, isto é, tanto em aplicações comerciais quanto em projetos de Defesa. Sendo o radar um sistema essencial utilizado no âmbito civil e militar, suas funcionalidades podem ser aprimoradas por meio da implantação de subsistemas baseados em técnicas fotônicas. O comportamento de diferentes formas de onda empregadas em sinais radar, quando transmitidos por um enlace fotônico, pode influenciar no desempenho do sistema. São analisados os efeitos provocadas pela transmissão de pulsos com modulação linear e não-linear de frequência (LFM e NLFM) por um enlace fotônico, em que a não-linearidade do modulador, polarizado no ponto de quadratura, resulta em uma função de transferência de terceira ordem. Adicionalmente, a geração de portadoras para pulsos radar com frequências nas faixas de micro-ondas e de ondas milimétricas, que apresentem alta estabilidade e baixo ruído de fase, é um desafio para a eletrônica convencional e compõe um requisito crítico para a operação do radar. Sistemas multiplicadores de frequências baseados em moduladores Mach-Zehnder, polarizados na região não-linear de sua curva, realizam essa função a partir de um sinal de referência com frequência mais baixa. É descrito um método analítico para inferir expressões exatas para a potência óptica e a corrente elétrica na saída do enlace fotônico com moduladores dual drive e moduladores dual parallel, permitindo especificar com precisão a intensidade dos harmônicos e a relação entre eles. Estas expressões são comparadas com resultados aproximados presentes na literatura e não requerem limitação de operação em regime de pequenos sinais. Simulações computacionais e resultados experimentais comprovam a eficiência do método e identificam a criticidade que os parâmetros dos dispositivos utilizados têm no espectro óptico e elétrico do sinal resultante.
118

Estudo das propriedades de transporte e armazenamento de cargas elétricas em filmes de Teflon FEP. / Study of the transport and storage properties of electric charges in Teflon FEP films.

Cardoso, Celso Xavier 04 April 1986 (has links)
No estudo do transporte e armazanamento de cargas elétricas, em filmes de Teflon FEP, utilizamos a Técnica de Pulso Térmico em conjunto com a Técnica de Corrente Termoestimulada em circuito aberto. Através das duas técnicas, pudemos acompanhar a evolução das cargas nas amostras (de 25 &#956m) submetidas ao Annealing e a descarga iônica em diferentes situações, comparando os resultados obtidos em amostras virgens com as amostras tratadas ou irradiadas. No caso das amostras irradiadas, verificamos que o contato era injetor de buracos e, posteriormente, sugerimos a dependência da mobilidade de buracos com o campo elétrico aplicado. Na tentativa de explicar os resultados obtidos, fizemos uso de alguns modelos teóricos de correntes limitadas por carga espacial. / The Heat Pulse and TSC (Thermo-Stimulated-Current) in open circuit techniques were used to study the transport and storage of injected charge in Teflon FEP films. Using these techniques it was possible to follow the evolution of the injected charge inside the samples. Virgin samples (as received), previously annealed samples and previously ionic bombarded samples were used. The results of treated samples were compared with the results of virgin samples. Aluminum evaporate contacts covering ionic bombarded surface show hole injection properties. Measurement of space charge limited currents shows a mobility dependent of the electrical field (&#956 &#945 E-1/2).
119

Conexão paralela de conversores estáticos do tipo fonte de tensão sem transformador - características e estratégias de controle. / Transformerless parallel connection of voltage source converters - characteristics and control strategies.

Matakas Junior, Lourenco 07 May 1998 (has links)
Os elevados níveis de potência e desempenho solicitados pelas presentes e futuras aplicações de conversores estáticos de potência podem ser atingidos pela interconexão de unidades básicas menores (multiconversor). Com a utilização de uma estratégia de controle adequada consegue-se não apenas a potência total desejada e sua correta divisão entre as várias unidades básicas como também uma redução no conteúdo harmônico das correntes e tensões resultantes. Neste trabalho, algumas topologias de multiconversores monofásicos do tipo fonte de tensão são modeladas, analisadas e comparadas quanto às solicitações de corrente e tensão nos diversos componentes, e quanto ao espectro da corrente resultante. Desta discussão conclui-se que a \"Conexão em Paralelo de Conversores Sem Transformador\" (PCTL- parallel connection/transformerless) é viável, levando-se em conta as demais topologias e a tecnologia disponível em semicondutores de potência. A análise do modelo matemático e da matriz de controlabilidade do caso PCTL trifásico resulta em métodos de desacoplamento das entradas do multiconversor. Baseando-se nestes métodos, são propostas três estratégias de controle utilizando controladores de corrente monofásicos individuais. Dois deles utilizam PWM com portadora triangular, e o outro, um PWM por banda de tolerância. Para um dos casos, baseados em PWM a portadora triangular, propõe-se um processo de minimização de harmônicos de corrente, injetando-se à referência de cada modulador PWM um sinal de \"seqüência zero instantânea\", obtido a partir da solução de um problema de otimização. Para o caso baseado em banda de tolerância, conseguem-se satisfazer os critérios de desacoplamento pela sincronização e igual defasagem das funções de chaveamento dos diversos conversores via malhas PLL, e também pela injeção de uma corrente fictícia de \"seqüência zero instantânea\" às referências do controlador de corrente. Para os controladores propostos, discute-se a operação do PCTL durante a ocorrência de falhas ou manutenção. Apenas os conversores do tipo fonte de tensão são abordados neste trabalho. / The high power and performance levels required for the present and future power electronics converters can be achieved by connecting a set of smaller power units (multiconverter). By using appropriate control, not only perfect sharing of the power among the converters, but also harmonics reduction is obtained. This thesis presents, analyses and compares some multiconverter topologies, based on the values of the voltages and currents in the main components and in the spectra of the resulting current. As a result, the transformerless parallel connection of converters PCTL is shown to be a feasible solution, taking into account the existing power devices technology. The analysis of the three phase PCTL model and its controllability matrix suggests methods for decoupling the PCTL inputs. This results in two methods using carrier based current controller and one method using a \"tolerance band (TB)\" based controller. For the carrier based one, the injection of an optimized zero sequence reference voltage produces a reduction in the ripple of the individual currents. For the tolerance based one, the inputs coupling is reduced by the use of PLL synchronized PWM and by the injection of a \"fictitious zero sequence current in the TB controller. The operation of the PCTL under faults and maintenance condition is discussed. Only the voltage source converter is studied here.
120

Estudo da redução do cobalto(II) em meio aquoso de azoteto de sódio por polarografia de pulso / Study of reduction of cobalt(II) in sodium azide aqueous medium by pulse polarography

Motta, Claudia Giovedi 16 March 1994 (has links)
A solução de cobalto(lI) em meio de perclorato de sódio apresenta uma onda polarográfica de redução próxima a -1,4 V em relação ao ECS a 25°C. A adição do ligante azoteto, N3-, causa a antecipação desta onda catódica para a região mais positiva de potencial. A máxima antecipação - de 320 mV - é atingida pela adição de 0,600 M do ligante. A antecipação da onda por ocasião da adição de azoteto, é explicada pela capacidade deste Iigante se adsorver sobre a superfície do mercúrio, formando uma ponte entre o eletrodo e o cátion metálico, facilitando a transferência de elétrons. A diminuição de sobretensão verificada com a adição do ligante reflete a queda da energia de ativação necessária para que ocorra a transferência de elétrons e como o azoteto é o responsável por este fenômeno, ele pode ser chamado de ligante catalítico. Critérios de caracterização para processos de eletrodo mostraram que a adição do ligante diminui o grau de irreversibilidade do processo de redução do cobalto(lI) - na técnica de pulso - em relação ao meio de perclorato. Em concentrações de azoteto inferiores a 0,600 M ocorre a antecipação gradativa da onda de redução do cobalto(lI) com um desdobramento em duas ondas com potenciais de meia-onda próximos a -1,1 V e -1,4 V, respectivamente. Da análise das curvas de distribuição das espécies complexas em equilíbrio concluiu-se ser a onda em -1,1 V correspondente à redução do azoteto-complexo de cobalto(ll) (presente já no seio da solução ou formado na superfície do eletrodo) e a onda em -1,4 V relacionada ao aquo-íon de cobalto(II). Especificamente na concentração de azoteto 0,160 M a onda na região de -1,1 V na polarografia de pulso diferencial apresentou um desdobramento bem nítido. Tal fato foi interpretado como transferência de elétrons por etapa ou, em outras palavras, entrada de elétrons com velocidades diferentes, possibilitando a existência de cobalto no estado monovalente ainda que por um lapso de tempo curto. Medições coulométricas a potencial controlado foram feitas em dois potenciais da onda do azoteto-complexo: (1) potencial em que ocorreu o desdobramento e (2) potencial limite. Em (1) o número de elétrons obtido foi menor que 2, a solução turvou-se devido à elevação do pH e a análise de toque na solução final detectou a presença do cátion amônio. Em (2) o número de elétrons obtido foi 2, a solução permaneceu límpida, e a análise de toque não determinou a presença de amônio. Os fatos observados em (1) reforçaram a hipótese da formação do intermediário de cobalto(l) que seria reoxidado a cobalto(lI) pelo HN3 produzindo NH4+ e N2. No caso (2), por sua vez, a redução possivelmente leva à formação de cobalto metálico, que não interage com o HN3. Outras evidências da formação de cobalto(l) obtidas foram: a) o número de elétrons fracionado e maior que 3 quando aumentou-se a concentração de HN3 no caso (1); b) a elevação significativa apenas da corrente associada ao primeiro pico (supostamente atribuído ao Co(l)) com a elevação da concentração de HN3 em solução; c) a quebra em duas retas, nas curvas de polarização, cujos coeficientes angulares foram maiores na presença de 0,160 M de azoteto e, finalmente d) a relação Ic/la, próxima de 1 quando o Ei no PPR foi fixado no potencial do desdobramento, e bem maior que 1, com Ei fixado no limite. / The electroreduction of Co(ll) in perchloric media gives origin to a polarographic wave about -1.4 V VS. SCE at 25°C. With the addition of the azide ligand, N3-, that wave shifts towards more positive potentials. The higher value of the potential shift, 320 mV, is recorded for the concentration 0,600 M of ligand. The shift can be explained by the adsorption of the azide ion on mercury electrodes, bridging the electrode and the metal ion, and promoting, then, the electron transfer more easily. With intermediary ligand concentrations the reduction wave of the cobalt ion breaks in two curves having walf-wave potentials around -1.1 and -1.4 V. Taking into account the distribution curve of the complexes species in equilibrium, it is concluded that the first wave corresponds to the azide complex of cobalt(lI) (already present in the solution or formed on the electrode surface), and the second one is related to the Co(lI) aquo íon. The wave correspondent to the reduction of azide complex, in the differential pulse polarography, too shows a splitting in two curves. This behavior dependents of the ligand concentration can be interpreted in terms of a stepwise charge transfer reaction, with the possible production of a labil Co(l) intermediate. Coulometric experiments performed at the potential where the breaks occurs, confirmed the supposition of the presence of Co(l) species, which could be oxidized to Co(ll) by HN3 yielding NH4+ and N2. Two linear regions exhibited by polarization curves in the solution 0,160 M azide and the Ic/la current ratio equal to 1, obtained by reverse pulse polarography with the initial potential coinciding with the potential at which break occurs, gave further evidences of the possible formation of Co(l) species.

Page generated in 0.0351 seconds