• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 40
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 40
  • 29
  • 16
  • 9
  • 8
  • 8
  • 8
  • 8
  • 7
  • 6
  • 6
  • 6
  • 6
  • 6
  • 6
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Resultados do tratamento radiocirúrgico de doentes com malformações arteriovenosas encefálicas classificadas como graus 3A, 3B, 4 ou 5 previamente submetidos ou não à embolização / The results of radiosurgical treatment of grade 3A, 3B, 4 and 5 cerebral arteriovenous malformations previously treated or not with embolization

Evandro César de Souza 04 May 2010 (has links)
Introdução: O risco do tratamento das malformações arteriovenosas encefálicas (MAVEs) é proporcional à sua graduação. O processo de seleção da técnica empregada depende, além da natureza e localização das MAVEs, das condições clínicas e idade dos doentes e da disponibilidade de profissionais treinados e de equipamentos apropriados no ambiente onde o doente é tratado. Objetivo: Avaliar a eficácia da radiocirurgia e da embolização prévia ao tratamento radiocirúrgico das MAVEs classificadas como graus 3A, 3B, 4 ou 5. Métodos e Resultados: O trabalho baseou-se na observação retrospectiva de prontuários clínicos e de arquivos de imagens de 90 doentes com diagnóstico de MAVEs classificadas como graus 3A, 3B, 4 ou 5 submetidos a tratamento com radiocirurgia precedida ou não de embolização no Departamento de Radioterapia e Radioterapia Estereotáctica, Neuroradiologia Intervencionista e Neurocirugia da Real e Benemérita Associação Portuguesa de Beneficência de São Paulo, de outubro de 1993 a outubro de 2008. As idades dos doentes variaram de sete a 60 anos (média de 30,6 anos ± 11,59 anos, mediana de 28 anos). Eram do sexo feminino 46 (51,1%) doentes. Todos foram submetidos a três exames de ressonância magnética (RM) ou tomografia computadorizada (TC) no primeiro ano de acompanhamento e a um exame de RM ou TC do encéfalo no segundo e terceiro anos. Quando um dos exames sugeriu oclusão da MAVE ou o período de acompanhamento foi maior que três anos, os doentes foram submetidos à angiografia digital do encéfalo. Em 51 (56,7%) dos 90 doentes tratados ocorreu oclusão completa da MAVE após a primeira radiocirurgia (1ª Rc), em 21 (23,3%) foram evidenciadas complicações clínica em 36 (40,0%), foram visibilizadas anormalidades no exame de RM. Em 30 (33,3%) doentes evidenciou-se hipersinal no encéfalo em T2 na RM xvi e, em seis (6,7%), radionecrose. Trinta e dois(82,0%) dos 39 doentes que não apresentaram oclusão completa da MAVE após a 1ª Rc foram submetidos à segunda radiocirurgia (2ª Rc). Ocorreu oclusão completa em 12 (37,5%) destes doentes, instalaram-se complicações clínicas em cinco (15,6%) e, anormalidades no exame de RM em oito (25,0%), ou seja, hipersinal em T2 na RM em três (9,5%) e radionecrose em cinco (15,6%). Conclusão: Concluiu-se que a radiocirurgia foi eficaz no tratamento das MAVEs graus 3A, 3B, 4 e 5, que as MAVEs classificadas como grau 3B devem tratadas, preferencialmente, apenas com radiocirurgia e que as MAVEs classificadas como 3A, 4 e 5 devem ser submetidas à embolização previamente à radiocirugia para reduzir-se sua graduação e seu fluxo sanguíneo / Introduction: The risk of treatment of the cerebral arteriovenous malformations (AVM) is proportional to their grade and is affected by the method used. The selection of the AVM therapeutic method depends of the vascular pattern and anatomical site, clinical condition and age of the patient, experience of the treating team and of the equipment available. Objectives: This study aimed the evaluation of the efficacy of the radiosurgical treatment of Grade 3A, 3B, 4 and 5 cerebral AVMs in patients previosly treated or not with embolization. Methods and Results: The data of the clinical notes and the computed tomography (CT) and magnetic ressonance (RM) images of the brain of 90 patients with Grade 3A, 3B, 4 or 5 cerebral embolised or not AVMs treated with radiosurgery at the Department of Radiotherapy, Stereotactic Radiotherapy, Interventional Neuroradiology and Neurosurgery at Real e Benemerita Associação Portuguesa de Beneficência de São Paulo were retrospectively reviewed. The ages of the patients ranged from 7 to 60 years of (average = 30.6 ± 11.59 years; median = 28 years) and 46 (51.1%) were female. During the first year after treatment three MR or CT scans of the brain were evaluated and one at the end of the 2nd and 3rd years after the treatment one MR or CT scan were re-evaluated respectively. When the brain scans suggest AVM occlusion, cerebral angiography was performed. In 51 of the 90 patients (56.7%) there was complete occlusion of the AVM after one radiosurgical treatment; 21 of the patients (23.3%) had clinical complications. In 36 patients (40.0%) new abnormalities of the MR became evident. Thirty (33.3%) presented T2 hypersignal and six (6.7%), had radionecrosis. From the 39 patients who did not had complete occlusion of the AVM, 32 (82.0%) had a second radiosurgical course of treatment; in 12 xviii (37.5%) the AVM became completely occluded but five (15.6%) had clinical complications. Eight (25.0%) of these patients presented new abnormalities at the MR scan of the brain; three (9.5%) had T2 hypersignal and five (15.6%) radionecrosis. Conclusions: Radiosurgery was effective in the treatment of Grade 3A, 3B, 4 and 5 cerebral AVMs , Grade 3B cerebral AVM should be treated only with radiosurgery without previous embolization, and Grade 3A, 4 and 5 AVMs should be treated with embolization to reduce their AVM grade and blood flow prior to radiosurgery
22

Avaliação de protocolo para redução da distorção em estereotaxia para ressonância magnética de três tesla / A method for geometric distortion correction for stereotaxic neurosurgery on three tesla

Wagner Malagó Tavares 07 December 2015 (has links)
Introdução: o presente estudo demonstra a aplicação de um algoritmo para correção de distorções em imagens de RM em 3T. Métodos: foi utilizado um Modelo Tridimensional com Alvos (MTA) de acrílico (Micromar, São Paulo, Brasil) montado em uma plataforma com as dimensões e características de um arco estereotáctico. O MTA foi submetido à aquisição de imagens em uma bobina de crânio utilizando o aparelho Philips 3T Magnetom Sigma LX(TM) (Philips Medical Systems, Eindhoven, Netherlands). Para cada aquisição duas imagens foram obtidas, a normal e a reversa (nRM e rRM, respectivamente). Foi aplicado o protocolo de correção com gradiente reverso para produzir coordenadas x, y e z corrigidas. Após ter sido determinada a acurácia dos alvos, foram submetidos 20 pacientes ao mesmo protocolo para determinar a validade em indivíduos. Resultados: a análise dos dados demonstrou que as diferenças entre observadores não foram estatisticamente significantes. Além disso, os pontos obtidos após o processo de retificação das coordenadas no MTA revelou uma distorção média de 1,05 mm. Nos pacientes, a distorção pré correção variava de 0 a 5,6 mm; após a correção variou entre 0 e 3,5 mm. Conclusão: o presente estudo examinou uma técnica de retificação das distorções geométricas encontradas em imagens de RM. Esta mostrou-se bem sucedida em produzir resultados consistentemente acurados para registro de alvos estereotácticos. A técnica pode ser aplicada de maneira universal a todas as imagens de RM adquiridas em protocolo spin-echo e corrige as distorções geométricas presentes / The present work presents an application of a image distortion correction algorithm for 3T MR images. Methods: We used a phantom head model (Micromar, São Paulo, Brazil) mounted on a plataform with the dimensions and features of a stereotactic frame. The phantom was scanned within the head coil of a Philips 3T Magnetom Sigma LX(TM) (Philips Medical Systems, Eindhoven, Netherlands). For each scan, 2 images were obtained - the normal and the reversed image (nMR and rMR, respectively). We applied the inverted gradient correction protocol to produce a corrected x, y and z coordinate. After we ensure target accuracy we submitted 20 patients to the same protocol to exactitude evaluation in human subjects. Results: For all the analyzed data, the differences among the observers were not statistically significant. Moreover, the data rectification proved to be effective as the average distortion on phantom, after correction, was 1.05 mm. On patients the pre-correction distortion varied between 0 and 5.6mm, after correction it varied between 0 mm and 3.5 mm. Conclusion: This study examined a rectifying technique for correcting geometric distortions encountered in the MR images, and the technique proved to be highly successful in producing consistently accurate stereotactic target registration. The technique is universally applicable to all routinely employed spin-echo MR images, and corrects for geometric distortions
23

Avaliação de protocolo para redução da distorção em estereotaxia para ressonância magnética de três tesla / A method for geometric distortion correction for stereotaxic neurosurgery on three tesla

Tavares, Wagner Malagó 07 December 2015 (has links)
Introdução: o presente estudo demonstra a aplicação de um algoritmo para correção de distorções em imagens de RM em 3T. Métodos: foi utilizado um Modelo Tridimensional com Alvos (MTA) de acrílico (Micromar, São Paulo, Brasil) montado em uma plataforma com as dimensões e características de um arco estereotáctico. O MTA foi submetido à aquisição de imagens em uma bobina de crânio utilizando o aparelho Philips 3T Magnetom Sigma LX(TM) (Philips Medical Systems, Eindhoven, Netherlands). Para cada aquisição duas imagens foram obtidas, a normal e a reversa (nRM e rRM, respectivamente). Foi aplicado o protocolo de correção com gradiente reverso para produzir coordenadas x, y e z corrigidas. Após ter sido determinada a acurácia dos alvos, foram submetidos 20 pacientes ao mesmo protocolo para determinar a validade em indivíduos. Resultados: a análise dos dados demonstrou que as diferenças entre observadores não foram estatisticamente significantes. Além disso, os pontos obtidos após o processo de retificação das coordenadas no MTA revelou uma distorção média de 1,05 mm. Nos pacientes, a distorção pré correção variava de 0 a 5,6 mm; após a correção variou entre 0 e 3,5 mm. Conclusão: o presente estudo examinou uma técnica de retificação das distorções geométricas encontradas em imagens de RM. Esta mostrou-se bem sucedida em produzir resultados consistentemente acurados para registro de alvos estereotácticos. A técnica pode ser aplicada de maneira universal a todas as imagens de RM adquiridas em protocolo spin-echo e corrige as distorções geométricas presentes / The present work presents an application of a image distortion correction algorithm for 3T MR images. Methods: We used a phantom head model (Micromar, São Paulo, Brazil) mounted on a plataform with the dimensions and features of a stereotactic frame. The phantom was scanned within the head coil of a Philips 3T Magnetom Sigma LX(TM) (Philips Medical Systems, Eindhoven, Netherlands). For each scan, 2 images were obtained - the normal and the reversed image (nMR and rMR, respectively). We applied the inverted gradient correction protocol to produce a corrected x, y and z coordinate. After we ensure target accuracy we submitted 20 patients to the same protocol to exactitude evaluation in human subjects. Results: For all the analyzed data, the differences among the observers were not statistically significant. Moreover, the data rectification proved to be effective as the average distortion on phantom, after correction, was 1.05 mm. On patients the pre-correction distortion varied between 0 and 5.6mm, after correction it varied between 0 mm and 3.5 mm. Conclusion: This study examined a rectifying technique for correcting geometric distortions encountered in the MR images, and the technique proved to be highly successful in producing consistently accurate stereotactic target registration. The technique is universally applicable to all routinely employed spin-echo MR images, and corrects for geometric distortions
24

Avaliação das metástases encefálicas antes e após radiocirurgia através de técnica de permeabilidade por ressonância magnética / Assessment of irradiated brain metastases using dynamic contrast-enhanced magnetic resonance imaging

Freitas, Daniela Batista de Almeida 03 June 2015 (has links)
Objetivo: Avaliar o efeito da radiocirurgia estereotática (RC) sobre a permeabilidade tumoral das metástases encefálicas, utilizando-se como parâmetro a o coeficiente de transferência de contraste (transfer coefficient, Ktrans) obtida pela técnica de permeabilidade por ressonância magnética (RM). Objetivou-se também avaliar a capacidade de medições Ktrans para prever a resposta volumétrica tumoral a médio prazo depois da RC. Métodos: Vinte e seis pacientes adultos com um total de 34 metástases encefálicas foram submetidos a exames de RM, com sequência dinâmica ponderada em T1, após administração de contraste, em magneto de 1,5 T, antes da RC (linha de base) e 4-8 semanas após o tratamento. A partir desta sequência, foram obtidos mapas paramétricos Ktrans e realizadas medições em regiões de interesse das lesões. Adicionalmente, imagens convencionais ponderadas em T1 pós-contraste foram obtidas pelo menos 16 semanas após a RC, a fim de avaliar a resposta volumétrica tumoral baseada na variação de volume. Resultados: A média ± (devio-padrão [DP]) do valor de Ktrans foi 0,13 ± 0,11 min-1 no exame inicial e 0,08 ± 0,07 min-1 após 4-8 semanas do tratamento (p < 0,001). Os pacientes foram seguidos em média por 7,9 ± 4,7 meses. Dezessete deles (22 lesões) foram submetidos a RM após 16 semanas do tratamento. Destes, 9 (41%) lesões tinham progredido no médio prazo. O aumento da medida de Ktrans após RC foi preditivo de progressão do volume tumoral (taxa de risco = 1,50, interval de confiança 95%: 1,16-1,70, p < 0,001), sendo que a elevação em 15% do valor de Ktrans mostrou uma sensibilidade de 78% e uma especificidade de 85% para a previsão de progressão do volume tumoral a médio prazo. Conclusão: RC está associada a redução dos valores Ktrans das metástases encefálicas no período pós-tratamento precoce. Além disso a variação Ktrans, medida através da técnica de permabilidade por RM, pode ser útil para prever a resposta do volume tumoral a médio prazo para este tratamento / Purpose: The purpose of this study was to evaluate the effect of stereotactic radiosurgery (SRS) on cerebral metastases using the transfer coefficient (Ktrans) assessed with dynamic contrast-enhanced (DCE) MRI. Furthermore, we aimed to evaluate the ability of Ktrans measurements to predict mid-term tumor outcomes after SRS. Methods: Twenty-six adult patients with a total of 34 cerebral metastases underwent T1-weighted DCE MRI in a 1.5T magnet at baseline (prior to SRS) and 4-8 weeks after treatment. Quantitative analysis of DCE MRI was performed generating Ktrans parametric maps, and region-of-interest-based measurements were acquired for each metastasis. Conventional MRI was performed at least 16 weeks after SRS to assess mid-term tumor outcome using volume variation. Results: The mean ± (Standard Deviation[SD]) Ktrans value was 0.13 ± 0.11 min-1 at baseline and 0.08 ± 0.07 min-1 after 4-8 weeks posttreatment (p < 0.001). The mean (± SD) total follow-up time was 7.9 ± 4.7 months. Seventeen patients (22 lesions) underwent mid-term MRI. Of those, 9 (41%) lesions had progressed at the mid-term follow-up. An increase in Ktrans after SRS was predictive of tumor progression (hazard ratio =1.50; 95% confidence interval: 1.16-1.70, p < 0.001). An increase of 15% in Ktrans showed a 78% sensitivity and 85% specificity for prediction of progression at mid-term follow-up. Conclusion: SRS was associated with a reduction of Ktrans values of the cerebral metastases in the early post-treatment period. Furthermore, Ktrans variation as assessed using DCE MRI may be helpful to predict mid-term outcomes after SRS
25

Capsulotomia ventro-capsular e ventro-estriatal por raios gama no transtorno obsessivo-compulsivo: avaliação inicial da eficácia e perfil de eventos adversos / Ventral capsular and ventral striatal gamma capsulotomy in obsessive-compulsive disorder: initial assessment of efficacy and profile of adverse events

Lopes, Antonio Carlos 29 August 2007 (has links)
Inúmeros estudos têm demonstrado que o Transtorno Obsessivo-Compulsivo (TOC) costuma cursar com uma taxa de resposta a tratamentos variando entre cerca de 60 a 80% dos casos, por meio do emprego de medicamentos inibidores de recaptação de serotonina, ou da terapia comportamental. Encontramos, no entanto, uma parcela de indivíduos portadores desta enfermidade os quais não respondem às opções terapêuticas clássicas, evoluindo com grave comprometimento psicossocial. Radiocirurgias estereotáxicas, como a capsulotomia anterior por raios gama, são uma opção terapêutica para estes pacientes. Recentemente, um aperfeiçoamento da capsulotomia anterior por raios gama foi desenvolvido na Universidade de Brown, denominado capsulotomia ventro-capsular e ventro-estriatal por raios gama, utilizando-se de lesões menores e tendo melhor perfil de eventos adversos. Faltam no entanto estudos detalhando a eficácia e o perfil de eventos adversos desta técnica. O objetivo deste estudo foi determinar se a capsulotomia ventro-capsular e ventro-estriatal por raios gama no TOC é eficaz quanto à redução de sintomas obsessivo-compulsivos e melhora clínica global e qual o perfil de eventos adversos, e de alterações neuropsicológicas e de personalidade do procedimento. Selecionaram-se 14 pacientes com TOC refratário, e que foram submetidos a esta técnica cirúrgica no país, cinco dos quais fizeram parte de um estudo piloto inicial. Os outros nove pacientes participaram de um ensaio clínico randomizado, duplo-cego, no qual um grupo se submeteu a radiocirurgia verdadeira (grupo ativo), enquanto o outro grupo recebeu uma falsa radiocirurgia (grupo placebo). Anteriormente ao procedimento, todos realizaram uma detalhada avaliação clínica/psiquiátrica, além de uma extensa bateria de instrumentos de diagnóstico psiquiátrico, gravidade e evolução do TOC, melhora clínica global, sintomas depressivos/ansiosos, e alterações neuropsicológicas e de personalidade. Os indivíduos foram periodicamente avaliados e acompanhados durante o período mínimo de um ano. Relativo ao estudo piloto, dois em cinco pacientes (40%) responderam ao tratamento após um ano de seguimento, ou três em cinco (60%) em até três anos de seguimento. No grupo ativo, um entre quatro pacientes (25%) respondeu ao tratamento em até um ano de seguimento, ou três entre quatro (75%) no período entre 12 e 24 meses de seguimento. No grupo placebo, nenhum dos cinco pacientes respondeu à falsa radiocirurgia. O evento adverso mais grave foi o desencadeamento de um episódio maníaco de curta duração, em apenas um paciente da amostra total. Alterações indesejáveis neuropsicológicas ou da personalidade não foram observadas neste estudo. Concluindo, este estudo sugere que a capsulotomia ventro-capsular e ventro-estriatal é relativamente eficaz, com poucos eventos adversos. / Several studies have demonstrated that good treatment responses in obsessive-compulsive disorder (OCD) are often obtained in 60 to 80 % of patients, whether employing serotonin reuptake inhibitors or behavior therapy. However, a subgroup of these patients does not respond to the conventional therapeutic options. Severe psychosocial impairments are meanwhile observed. Stereotactic radiosurgeries, such as Gamma Knife anterior capsulotomy is a treatment option for these subjects. A smaller Gamma Knife capsulotomy technique, termed ventral capsular and ventral striatal gamma capsulotomy, has been recently developed at Brown University, with few adverse events. On the other hand, there is a lack of studies describing the efficacy and adverse events associated to this new technique. The aim of this study was to determine whether ventral capsular and ventral striatal gamma capsulotomy is efficacious in terms of obsessive-compulsive symptoms reductions and clinical global improvements, as well as to report the profile of adverse events, and neuropsychological and personality changes associated to this procedure. Fourteen refractory OCD patients were selected to be submitted to this new radiosurgical technique. Five subjects were operated in an open, pilot study. The other nine patients took part in a double-blind, randomized controlled trial, consisting of an active group (which received true radiosurgery) and a placebo group (with sham radiosurgery patients). All subjects were previously evaluated by a preliminary clinical/psychiatric interview, as well as by extensive specific instruments regarding psychiatric diagnosis, OCD evolution and severity, clinical global improvements, anxiety/depression symptoms, and neuropsychological and personality changes. All patients were offered periodical follow-up visits for a minimum of one year. Regarding the pilot study, two of five patients (40%) responded to treatment after one year of follow-up, while three of five (60%) responded after three years of follow-up. In the active group, one out of four patients (25%) responded to treatment until one year of follow-up, while three out of four subjects (75%) responded in the period between 12 and 24 months of follow-up. None of the five patients in the placebo group had responded to the false radiosurgery. The most serious adverse event was the development of a short-term, manic episode, in only one patient. Adverse neuropsychological and personality changes were not observed in this study. In conclusion, this study suggests that ventral capsular and ventral striatal gamma capsulotomy is a relatively efficacious procedure, with few adverse events.
26

Verificação 3D da distribuição da dose em radiocirurgia estereotáxica através de simulação Monte Carlo e dosimetria por ressonância magnética nuclear / Dose distribution verification in 3D to stereotactic radiosurgery through Monte Carlo simulation and gel dosimetry with nuclear magnetic resonance 2012

Alva Sánchez, Mirko Salomón 24 October 2012 (has links)
A radiocirugia estereotáxica é uma técnica que fornece altas doses de radiação utilizando campos pequenos para conformação da dose no volume alvo do tratamento. Devido à complexidade desta técnica torna-se necessária a verificação da distribuição de dose no volume de tratamento. Neste trabalho, as distribuições tridimensionais (3D) de doses de casos clínicos de neoplasias cranianas foram estudadas utilizando-se um objeto simulador de cabeça. A reconstrução das distribuições de doses nos volumes alvo e nas regiões adjacentes a estes foram avaliadas com o código de simulação PENELOPE, o dosímetro MAGIC-f gel e com o sistema de planejamento iPlan. Filmes radiocrômicos também foram empregados para a determinação das distribuições de dose em planos do tratamento. As respostas obtidas com as ferramentas dosimétricas utilizadas foram analisadas através de distribuições de índices gama, comparando-se os mapas centrais das distribuições de dose obtidas com as quatro ferramentas dosimétricas utilizadas. Usando-se critérios de tolerância de 3% e 3mm, a análise realizada na região da prescrição de dose (isodoses de 95%) mostrou-se equivalente para todas as ferramentas dosimétricas utilizadas; resultado diferente foi observado para isodoses menores, com uma equivalência máxima de 76,5%. As distribuições volumétricas, obtidas através do PENELOPE, MAGIC-f gel e o iPlan, foram comparadas, ainda, através dos histogramas dose-volume, para cada caso estudado, mostrando que 95% da dose absorvida relativa encontra-se dentro do volume alvo para todos os planos estudados. A probabilidade de controle tumoral, TCP, foi avaliada para os casos de radiocirurgia estudados, a partir das distribuições volumétricas de dose, resultando em uma probabilidade de controle tumoral máxima de 72%, para todos os casos, conforme o modelo matemático de TCP utilizado. Das comparações realizadas pode-se inferir que o dosímetro MAGIC-f gel e o código de simulação PENELOPE-Monte Carlo podem ser utilizados para determinar as distribuições de dose em 3D para a técnica de radiocirurgia estereotáxica. Essas ferramentas dosimétricas podem, dessa forma, auxiliar no comissionamento de unidades de terapia e em verificações 3D de doses do tratamento dos pacientes, permitindo avaliações dentro e ao redor do volume alvo e podendo se tornar ferramentais de rotina nos serviços de radioterapia. / Stereotactic radiosurgery is a technique which delivers high radiation doses using small fields to conform the absorbed dose into the target volume. Due to the complexity of this technique it is necessary to verify the dose distribution in the treatment volume. Thus, in this study the three-dimensional (3D) dose distributions of selected clinical cases of cranial tumors were obtained using a head phantom. The the dose distributions of target volumes and adjacent regions were evaluated with PENELOPE Monte Carlo simulation code, MAGIC-f dosimeter and iPlan® treatment planning system. Radiochromic films were also used to determine the dose distribution on selected plans of the treatment. The obtained results for the proposed dosimetric tools were analyzed by the gamma index distributions, comparing the maps of the central dose distributions obtained with the four dosimetric tools. Using the dose criteria of 3% in 3 mm, the gamma index test showed equivalence in the region of dose prescription (95% isodose) and a different result was observed for lower isodoses, with maximum accordance of 76.5%. The volumetric dose distributions obtained with PENELOPE, MAGIC-f and iPlan were also compared using the dose-volume histograms for each studied case, showing that 95% of the absorbed dose yield within the target volume. The tumor control probability, TCP, was evaluated for the studied radiosurgery cases, from the dose distributions-volumetric, resulting in a maximum probability of tumor control of 72% for all cases, for the used mathematical model of TCP. From the results it can be inferred that the MAGIC-f gel dosimeter and the PENELOPE Monte Carlo simulation code can be used to determine 3D dose distributions for stereotactic radiosurgery. These dosimetric tools can assist the commissioning of treatment units and 3D dose verifications of patients treatments, allowing assessments in and around the target volume and may become routine in radiotherapy services.
27

Avaliação das metástases encefálicas antes e após radiocirurgia através de técnica de permeabilidade por ressonância magnética / Assessment of irradiated brain metastases using dynamic contrast-enhanced magnetic resonance imaging

Daniela Batista de Almeida Freitas 03 June 2015 (has links)
Objetivo: Avaliar o efeito da radiocirurgia estereotática (RC) sobre a permeabilidade tumoral das metástases encefálicas, utilizando-se como parâmetro a o coeficiente de transferência de contraste (transfer coefficient, Ktrans) obtida pela técnica de permeabilidade por ressonância magnética (RM). Objetivou-se também avaliar a capacidade de medições Ktrans para prever a resposta volumétrica tumoral a médio prazo depois da RC. Métodos: Vinte e seis pacientes adultos com um total de 34 metástases encefálicas foram submetidos a exames de RM, com sequência dinâmica ponderada em T1, após administração de contraste, em magneto de 1,5 T, antes da RC (linha de base) e 4-8 semanas após o tratamento. A partir desta sequência, foram obtidos mapas paramétricos Ktrans e realizadas medições em regiões de interesse das lesões. Adicionalmente, imagens convencionais ponderadas em T1 pós-contraste foram obtidas pelo menos 16 semanas após a RC, a fim de avaliar a resposta volumétrica tumoral baseada na variação de volume. Resultados: A média ± (devio-padrão [DP]) do valor de Ktrans foi 0,13 ± 0,11 min-1 no exame inicial e 0,08 ± 0,07 min-1 após 4-8 semanas do tratamento (p < 0,001). Os pacientes foram seguidos em média por 7,9 ± 4,7 meses. Dezessete deles (22 lesões) foram submetidos a RM após 16 semanas do tratamento. Destes, 9 (41%) lesões tinham progredido no médio prazo. O aumento da medida de Ktrans após RC foi preditivo de progressão do volume tumoral (taxa de risco = 1,50, interval de confiança 95%: 1,16-1,70, p < 0,001), sendo que a elevação em 15% do valor de Ktrans mostrou uma sensibilidade de 78% e uma especificidade de 85% para a previsão de progressão do volume tumoral a médio prazo. Conclusão: RC está associada a redução dos valores Ktrans das metástases encefálicas no período pós-tratamento precoce. Além disso a variação Ktrans, medida através da técnica de permabilidade por RM, pode ser útil para prever a resposta do volume tumoral a médio prazo para este tratamento / Purpose: The purpose of this study was to evaluate the effect of stereotactic radiosurgery (SRS) on cerebral metastases using the transfer coefficient (Ktrans) assessed with dynamic contrast-enhanced (DCE) MRI. Furthermore, we aimed to evaluate the ability of Ktrans measurements to predict mid-term tumor outcomes after SRS. Methods: Twenty-six adult patients with a total of 34 cerebral metastases underwent T1-weighted DCE MRI in a 1.5T magnet at baseline (prior to SRS) and 4-8 weeks after treatment. Quantitative analysis of DCE MRI was performed generating Ktrans parametric maps, and region-of-interest-based measurements were acquired for each metastasis. Conventional MRI was performed at least 16 weeks after SRS to assess mid-term tumor outcome using volume variation. Results: The mean ± (Standard Deviation[SD]) Ktrans value was 0.13 ± 0.11 min-1 at baseline and 0.08 ± 0.07 min-1 after 4-8 weeks posttreatment (p < 0.001). The mean (± SD) total follow-up time was 7.9 ± 4.7 months. Seventeen patients (22 lesions) underwent mid-term MRI. Of those, 9 (41%) lesions had progressed at the mid-term follow-up. An increase in Ktrans after SRS was predictive of tumor progression (hazard ratio =1.50; 95% confidence interval: 1.16-1.70, p < 0.001). An increase of 15% in Ktrans showed a 78% sensitivity and 85% specificity for prediction of progression at mid-term follow-up. Conclusion: SRS was associated with a reduction of Ktrans values of the cerebral metastases in the early post-treatment period. Furthermore, Ktrans variation as assessed using DCE MRI may be helpful to predict mid-term outcomes after SRS
28

Dosimetria dos sistemas de radiocirurgia estereotáxica com aceleradores lineares equipados com colimadores micro multi-lâminas

Vieira, André Mozart de Miranda 19 February 2008 (has links)
Neste trabalho, as doses absorvidas produzidas em água pelo feixe de radiação de um Acelerador Linear Clínico - CLINAC 600C TM (Varian), com feixes de fótons de 6MV, foram avaliadas teórica e experimentalmente em configurações de campos quadrados, em seguida, em configurações de campos estreitos e circulares, obtidos com um colimador micro multi-lâminas - mMLC m3TM (BrainLab). A avaliação teórica foi feita por meio de cálculos com o Método de Monte Carlo. As curvas de porcentagem de dose profunda PDP e respectivas razões tecido máximo TMRs derivadas, do CLINAC 600C, medidas experimentalmente, foram validadas por meio de comparações com valores de referência, bem como com medidas usando diferentes detectores. Os resultados indicam diferenças menores que 5% pontualmente e em média menores que 1,5% para cada campo avaliado, quando comparados aos valores do comissionamento anterior (realizado no ano de 1999) e aos valores da literatura. Na comparação das medidas feitas com câmara de ionização e com diodo, a média das diferenças pontuais das curvas de PDP foi de -0,6% e as diferenças entre os perfis laterais de dose ficaram dentro de 1%, na região plana. O diodo fornece medidas de perfil com melhor resolução espacial. Os fatores relativos de dose dos campos abertos, atualizados, concordam com os valores de referência anteriores dentro de 1,03% de discrepância. As curvas de distribuição de dose absorvida em água, atualizadas, são, agora, consideradas de referência e permitem caracterizar o feixe desse CLINAC para o cálculo de dose em pacientes. Os espectros de fótons resultantes das simulações por Monte Carlo com os códigos PENELOPE e MCNP concordam em aproximadamente 80% dos pontos amostrados, sendo que as energias médias de (1,6 ± 0,3)MeV, com o MCNP, e de (1,72 ± 0,08)MeV, com o PENELOPE, são coincidentes. O modelo de fonte simples do CLINAC 600C, criado com o código PENELOPE, permite calcular as distribuições de dose em água, de campos abertos, com discrepâncias da ordem de ±1,0% na dose e de ±0,1 cm na posição, se comparados a medidas experimentais. Esses valores de discrepância atingem os critérios propostos inicialmente para validar o modelo de simulação e garantir sua aplicabilidade nas avaliações dosimétricas da Radioterapia desse CLINAC. A descrição geométrica do mMLC m3 para fins de simulação pelo Método de Monte Carlo, utilizando o código PENELOPE, foi considerada satisfatória ao permitir avaliar a transmissão desse colimador dentro de uma incerteza de ±0,2% e calcular uma subdosagem média de (11,4±2,0)%, devida ao efeito lingüeta-vão, que coincide com o valor determinado experimentalmente de (12,5±2,7)%, específicos para esse projeto de colimador. Os programas de simulação por Monte Carlo, que fazem o uso de um modelo de fonte simples do CLINAC 600C, combinado com o modelo completo do mMLC m3, permitiram calcular PDPs em água, de campos conformados, dentro do intervalo de ±1% de discrepância, enquanto que os fatores relativos de dose de campos conformados pelo mMLC puderam ser calculados com incertezas que variam de 1 a 3% concordando com os valores experimentais. Esses campos avaliados representam campos próximos àqueles usados nos tratamentos. Os resultados do trabalho garantem um conhecimento dosimétrico maior do colimador micro multi-lâminas m3, utilizado nas técnicas de radioterapia e radiocirurgia estereotáxica tridimensionais, e fornece uma ferramenta útil na avaliação das doses produzidas em configurações de campos complexas. / In this work, absorbed dose to water produced by the radiation beam of a clinical linear accelerator - CLINAC 600C TM (Varian), with a photon beam of 6 MV, were evaluated both theoretically and experimentally. This determination includes square and circular field configurations, the last one obtained with a micro multileaf collimator - mMLC m3TM (BrainLab). Theoretical evaluation was performed throughout Monte Carlo method. Experimental measurements of Percentage Depht Dose - PDD and derived Tissue Maximum Ratio - TMR curves from CLINAC 600C were validated by comparison with reference values as well as with measurements using different detectors. The results indicate local differences smaller than 5% and average differences smaller than 1,5% for each evaluated field, if they are compared to the previous commissioning values (made in 1999) and to the values of literature. Comparisons of ionization chamber and diode result in an average local difference of -0,6% for PDD measurements, and within 1% for lateral dose profiles, at depth, in the flat region. Diode provides measurements with better spatial resolution. Current output factors of open fields agree with reference values within 1,03% of discrepancy level. Current absorbed dose distributions in water are, now, considered reference values and allow characterization of this CLINAC for patient dose calculation. The photon spectra resulting from simulations with PENELOPE and MCNP codes agree approximately in 80% of the sampled points, in what average energies of (1,6 ± 0,3)MeV, with MCNP, and of (1,72 ± 0,08)MeV, with PENELOPE, are coincident. The created simple source model of the CLINAC 600C, using the PENELOPE code, allows one to calculate dose distributions in water, for open fields, with discrepancies of the order of ±1,0% in dose and of ±0,1cm in position, if they are compared to experimental measurements. These values met the initial proposed criteria to validate the simulation model and guarantee its applicability in dosimetric evaluations of radiotherapy with this CLINAC. The geometrical description of the mMLC m3 for Monte Carlo purposes, using the PENELOPE code, was considered satisfactory, providing the characterization of relevant physical parameters such as the transmission of the mMLC, within an estimated uncertainty of ±0,2%, and the average underdose of (11,4±2,0)%, due the tongue and groove effect, which is coincident with the experimental value of (12,5±2,7)%, for this particular collimator design. The Monte Carlo simulation codes which combine a single source model of the CLINAC 600C with the full m3 model, allows to calculate dose distributions in water for conformal beams within the discrepancy level of ±1%. However, output factors of conformal beams with the mMLC can be calculated with uncertainties varying from 1 to 3%, when they are compared to experimental results. These evaluated fields represent, and come close to treatment fields. The results of this work guarantee a better dosimetric knowledge of the micro multileaf collimator m3, which is used in three-dimensional stereotactic radiotherapy and radiosurgery techniques. This provides a useful tool in the evaluation of the mMLC as well as the absorbed doses produced in complex field configurations.
29

Estudo e desenvolvimento de um modelo de análise de risco para Radiocirurgia intracraniana / Study and development of a risk analysis model to radiosurgery

Flávia Cristina da Silva Teixeira 17 August 2015 (has links)
Mundialmente, eventos relatados constituídos por incidentes e acidentes em radioterapia, tem aumentado ao longo dos últimos 25 anos e a maioria destes eventos são resultados de falha humana, além de terem ocorrido com maior frequência em centros sofisticados que utilizam alta tecnologia. Em radioterapia a Gestão da Qualidade necessita de uma abordagem prospectiva através de análise de risco. Esta abordagem é defendida por recentes publicações por ser atualmente uma urgência em virtude do expressivo número de acidentes ocorridos. Dada a complexidade do processo em radioterapia, a busca pela qualidade do tratamento de forma a garantir a segurança do paciente é um dos assuntos mais discutidos mundialmente. Embora apenas 14% dos centros de radioterapia no Brasil ofereçam tratamentos com a técnica de radiocirurgia intracranial (SRS), estudos relativos a qualidade do tratamento relacionada a segurança do paciente submetido à esta técnica, é de relevante importância, pois qualquer desvio da dose prescrita é considerado muito mais crítico que em outras modalidades de tratamento radioterápico, já que são utilizadas altas doses de radiação que em geral variam de 10 Gy a 40 Gy para lesões até 50 mm de diâmetro, que são aplicadas em uma única fração ou até cinco frações. Tendo em vista tais conhecimentos, o objetivo deste trabalho foi atender um novo paradigma de Gestão da Qualidade, através do desenvolvimento de um modelo de análise de risco e de um Índice de Qualidade para a SRS no Brasil, a partir da técnica de Mapa do Processo e FMEA utilizadas pelo TG 100/AAPM. O trabalho foi desenvolvido em três centros de radioterapia de referência em alta tecnologia, dois localizados no Rio de Janeiro e um em São Paulo. Um Mapa do Processo de SRS foi identificado em cada centro de radioterapia e em seguida foi aplicada a técnica FMEA para todos os subprocessos identificados no mapa. A partir dos valores de NPR obtidos pela FMEA foi realizado um ranqueamento dos modos de falha. Modos de falha com NPR &#8805; 100 e S &#8805; 7 foram escolhidos como prioridade para implementação de estratégias de segurança. A partir das pontuações do parâmetro S atribuídas na aplicação da FMEA foi criado o Índice de Severidade (IS) e um Índice de Qualidade (IQ) foi criado a partir de uma relação entre o NPR e o IS. O resultado deste estudo, indica que as estratégias de segurança sejam implementadas para os 10 primeiros modos de falha do ranking e uma reavaliação do processo deve ocorrer a cada 1 ano. É também indicado que o IQ obtenha uma melhora mínima de 9% após a reavaliação do processo. De forma geral, o estudo mostrou que a adoção da ferramenta FMEA juntamente com o IQ são de fato justificadas, por minimizar os riscos para o paciente, melhorando a qualidade do tratamento aprimorando a segurança, criando mecanismos que permitam a garantia de que a dose será entregue de forma precisa e exata, e consequentemente, aumentando as chances de cura ou do controle local com uma desejada qualidade de vida para estes pacientes. / The reported events in radiotherapy that constitute accidents or incidents have increased worldwide in the last 25 years. Most of these events resulted from human failure and have happened in radiotherapy centers that use high technologies. The radiotherapy Quality Management needs a prospective approach through risk analysis. This approach is supported by recent publications as this actually extremely needed due the large number of accidents. Because of the complexity of the process in radiotherapy, the search for quality of care in order to ensure patient safety is one of the most discussed topics worldwide. Although only 14% of radiotherapy centers in Brazil offer treatments with intracranial radiosurgery technique (SRS), studies about the quality of care related to the safety of patients undergoing this technique is of great importance. Any deviations from the prescribed dose using SRS technique is considered more critical than in other methods of radiation treatment, as the delivered doses in SRS are higher, in the range of 10 Gy to 40 Gy, to lesions up to 50 mm in diameter, which are delivered in a single fraction or in five fractions. In view of those information, this work aims to satisfy the new Quality Management paradigm by developing a risk analysis model, and a Quality Index for SRS in Brazil, through the techniques of Process Map and FMEA used in the TG100/AAPM. The study was performed in three high technology reference radiotherapy centers, two located in Rio de Janeiro city and one in Sao Paulo city. A SRS Process Map was identified for each radiotherapy center, and then FMEA technique was applied in every subprocesses identified on the map. From NPR values obtained by the FMEA a ranking of failure modes was held. Failure modes with NPR &#8805; 100 and S &#8805; 7 were chosen as priority to implement safety strategies. From the scores assigned to the S parameter in the implementation of FMEA a Severity Index (SI) and a Quality Index (QI) were created from an association between the NPR and the SI. The result of this study indicates that safety strategies should be implemented for the first 10 failure modes of the ranking, and a new evaluation of the process should occur every year. In addition, it is also indicated that the QI shows a minimum improvement of 9 % after the re-evaluation of the process. Overall, the study showed that the adoption of the FMEA tool together with the QI are justified as they minimize the risks to the patient, improving the quality of care and enhancing the safety Taken together the FMEA and the QI create mechanisms for ensuring that the dose will be delivered more precisely and accurately, and consequently, this increases the chances of cure or local control of the tumor, improving quality of life of the patients.
30

Alterações na personalidade após procedimento de capsulotomia ventral anterior por raios gama em pacientes com transtorno obsessivo-compulsivo (TOC) refratário / Personalty change after gamma ventral capsulotomy in refractory obsessive-compulsive disorder (OCD) patients

Raquel Reis de Paiva 16 August 2017 (has links)
O Transtorno Obsessivo-Compulsivo (TOC) consiste em uma doença crônica caracterizada pela presença de obsessões e/ou compulsões. Em geral, cerca de 20% são pacientes considerados refratários por não responder a múltiplas intervenções de tratamento de primeira linha. Para esses pacientes, os tratamentos cirúrgicos são opções a serem consideradas. Dentre esses, destaca-se a capsulotomia ventral anterior por raios gama (radiocirurgia Gamma-Knife). Estudos clínicos e neuropsicológicos com a radiocirurgia Gamma-Knife em pacientes com TOC demonstraram eficácia e segurança desse procedimento. No entanto, não foram encontrados na literatura estudos de personalidade com esse tratamento no TOC. Portanto, o objetivo deste estudo foi investigar mudanças de personalidade após um ano da capsulotomia ventral anterior por raios gama em pacientes com TOC refratário. A avaliação da personalidade foi feita através do Inventário de Personalidade NEO revisado (NEO PI-R) e do Inventário de Temperamento e Caráter de Cloninger (TCI) em quatorze pacientes com TOC refratário antes e após um ano da radiocirurgia Gamma-Knife. Comparações dos dados de personalidade entre pacientes respondedores (n=5) ao tratamento e não respondedores (n=9) e análises de regressão com método stepwise bidirecional de seleção de variáveis foram realizadas. Como resultado principal, não foi encontrada piora de personalidade após a radiocirurgia. Ao contrário, encontrou-se uma tendência de diminuição dos escores de Neuroticismo e Persistência e, em geral, os dados dos pacientes se aproximaram dos dados dos controles. No que diz respeito aos respondedores, houve uma diminuição nos escores da dimensão de Neuroticismo e um aumento da dimensão de Extroversão significativos após um ano de tratamento, enquanto que os pacientes não respondedores não tiveram mudanças em quesito de personalidade. Predição de percentual de redução dos escores de YBOCS foi encontrada para as escalas de TCI, tendo contribuição do percentual de mudança das dimensões de Busca de novidades, Persistência, Autodirecionamento e Cooperatividade foram significantes em predizer o percentual de mudança de YBOCS. Busca de novidades, Dependência de Gratificação, Autodirecionamento e Cooperatividade foram significantes em predizer o percentual de mudança de funcionamento global. Essa melhora no funcionamento global depois da radiocirurgia nos pacientes com TOC pode estar relacionada ao aumento de motivação para começar e completar tarefas, perseguir objetivos e engajar-se com terceiros. Contudo, conclui-se que o procedimento de capsulotomia ventral anterior por raios gama para o tratamento de TOC não é somente seguro em termos de mudanças de personalidade, mas também pode melhorar algumas de suas dimensões / Obsessive-Compulsive Disorder (OCD) is a chronic disease characterized by the presence of obsessions and/or compulsions. In general, about 20% of OCD patients are considered refractory for not responding to multiple first-line treatment interventions. Performing surgical procedures such as gamma ventral capsulotomy (GVC) is an option to be considered for the treatment of refractory OCD patients. Clinical and neuropsychological studies with GVC in OCD patients have demonstrated the efficacy and safety oh this procedure efficacy and safety. However, personality studies with this treatment in OCD are not found in literature. The objective of this study was to investigate personality changes after one year of GVC in refractory OCD patients. Personality assessment was performed using the Revised NEO Personality Inventory (NEO PI-R) and the Cloninger\'s Temperament and Character Inventory (TCI) in fourteen refractory OCD patients before and one year after GVC. Personality data comparisons between treatment responders (n = 5) and non-responders (n = 9), and also linear regressions using a stepwise bidirectional elimination approach for variables selection were performed. As the main result, no impairment in personality was found after GVC. On the contrary, there was a decrease tendency in Neuroticism and Persistence scores and in general, patients\' data approached to controls\'. Patients responders presented a reduction in Neuroticism scores and an increase in Extraversion scores, whereas non-responders did not change personality. Persistence, Selfdirectedness and Cooperativeness were significant in predicting percentage of change in YBOCS scores. Novelty Seeking, Reward Dependence, Selfdirectedness and Cooperativeness were significant in predicting the percentage of improvement in global functioning. This improvement in global functioning after GVC could be thought of as relating to better motivation to begin tasks, pursue goals, complete tasks, and engage with others. In conclusion, GVC procedure for OCD treatment is not only safe in terms of personality changes, but it can also improve some of its dimensions

Page generated in 0.0369 seconds