• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 393
  • 140
  • 74
  • 72
  • 4
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 686
  • 277
  • 276
  • 276
  • 276
  • 212
  • 191
  • 190
  • 62
  • 50
  • 49
  • 48
  • 47
  • 47
  • 47
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
381

Liposomes as versatile tools: nanoreactors, membrane models and drug delivery carriers.

Clergeaud Veiga, Gael 16 December 2014 (has links)
Les molècules lipídiques poden formar nombroses estructures supramoleculars a través de les seves propietats d’autoacoblament en ambients aquosos. Una de les estructures més explorades, els liposomes, son formades quan les bicapes lamelars s’encorben en vesícules tancades amb un nucli aquós al seu interior. Aquesta particular organització, que ofereix ambients hidrofílic (nucli) i hidrofòbic (dins de la membrana) per poder transportar molècules polars i apolars, juntament amb la seva naturalesa biocompatible, biodegradable i no immunogènica, fa que els liposomes siguin una de les pedres angulars de la nanobiotecnologia. En conseqüència, els liposomes han estat àmpliament establerts com a eines versàtils en un gran nombre d’aplicacions, incloent productes farmacèutics, cosmètics, tecnologia dels aliments, com a models de membranes biològiques, com amplificadors de senyal en ciències analítiques, nanoreactors, eines de diagnòstic i un ampli etcètera. En aquest treball hem demostrar l’ús dels liposomes com a nanoreactors o plantilles per la síntesis de nanopartícules metàl·liques de forma i mida controlada. A més, els liposomes també s’han utilitzat com a models de membrana que imiten la membrana plasmàtica de la cèl·lula per la determinació de la activitat ionòfora de diferents compostos fenòlics dietètics fins al zinc. Per últim, ha estat explorada la capacitat dels liposomes pel transport i la entrega de medicaments amb la finalitat de desenvolupar el potencial dels liposomes, sensibles a la degradació específica per un enzim, com a vehicles de fàrmacs per la encapsulació d’oxaliplatí pel tractament del càncer de colon. En resum, el treball presentat en aquesta tesi doctoral enforteix la visió dels liposomes com eines versàtils que poden ser utilitzades en diferents aplicacions científiques. / Las moléculas lipídicas pueden formar numerosas estructuras supramoleculares gracias a sus propiedades de auto ensamblaje en ambientes acuosos. Una de las estructuras más exploradas, los liposomas, son formados cuando bicapas laminares se curvan produciendo vesículas cerradas con un núcleo acuoso en el interior. Esta particular organización, la cual ofrece ambientes hidrófilos (en el núcleo) e hidrófobos (dentro de la membrana) para poder transportar moléculas polares y apolares, junto con su naturaleza biocompatible, biodegradable y no inmunogenica, hace que los liposomas sean una de las piezas claves en el ámbito de la nanobiotecnologia. En consecuencia, los liposomas han sido ampliamente establecidos como herramientas versátiles en un gran número de aplicaciones, incluyendo productos farmacéuticos, cosméticos, tecnología de los alimentos, como modelos de membranas biológicas, amplificadores de señal en ciencias analíticas, nanoreactores, herramientas de diagnóstico y un amplio etcétera. En este trabajo hemos demostrado el uso de liposomas como nanoreactores o plantillas para la síntesis de nanopartículas metálicas de forma y tamaño controlada. Además, los liposomas también se utilizaron como modelos de membrana que imitan la membrana plasmática de la célula para la determinación de la actividad ionófora de varios compuestos fenólicos dietéticos hacia el zinc. Por último, la capacidad de los liposomas para el transporte y entrega de medicamentos ha sido explorada con el fin de desarrollar el potencial de liposomas que son sensibles hacia la degradación específica por una enzima como vehículos de fármacos para la encapsulación de oxaliplatino para el tratamiento del cáncer de colon. En resumen, el trabajo presentado en esta tesis doctoral fortalece la visión de los liposomas como herramientas versátiles que pueden ser utilizadas en diferentes aplicaciones científicas. / Lipid molecules can form numerous supramolecular structures through their self-assembly properties displayed within aqueous environments. One of the most explored structures, the liposomes, are formed when lamellar bilayers bend into closed vesicles containing an aqueous core inside. This particular structural organization, offering hydrophilic (core) and hydrophobic (within the membrane) environments to carry both polar and non-polar molecules,as well as their biocompatible, biodegradable and non-immunogenic properties, make liposomes as one of the cornerstones of nanobiotechnology. Consequently, liposomes have been extensively established as versatile tools in a large number of applications including pharmaceutics, cosmetics, food technology, models as biological membranes, signal amplifiers in analytical sciences, nanoreactors, diagnosing tools and a wide so on. In summary, the work presented in this doctoral thesis strengthens the view of liposomes as versatile tools that can be used in many different scientific applications. Liposomes were exploited as nanoreactors or templates for the shape and size controlled synthesis of metal nanoparticles. Furthermore, liposomes were used as membrane models that mimic the cell plasma membrane for the determination of zinc ionophore activity of several dietary phenolic compounds. Ultimately, the ability of liposomes to carry and delivery drugs was explored in order to investigate the potential of enzyme-degradable liposomes as drug carriers for the encapsulation of oxaliplatin to effectively enhance its pharmacokinetics for the treatment of colon cancer. In summary, the work presented in this thesis strengthens the vision of liposomes as a versatile tool that can be used in different scientific applications.
382

La osteopatía como instrumento de reducción de costes en el sistema sanitario español

Ponce, David, 1968- 24 October 2014 (has links)
Osteopathy has gained recognition within the field of medicine and physiotherapy. Its recognition within society has meant that many people use osteopathy as a means to achieving quality of life. The purpose of the study was to answer the question, whether it is possible to reduce healthcare costs using osteopathy to improve or cure ailments related pathologies that people have. Similarly, to assess the current situation of Osteopathy in the Spanish health system and propose it as a tool to reduce healthcare costs. Through a systematic review of literature data yielded information linked to object research were obtained. At the same time a field of non-experimental in order to determine the relative to the implementation of Osteopathy to reduce public health costs lead was developed. To reach certain conclusions, it was necessary to develop a work-study, which included the implementation of surveys on 401 medical health professionals framed within the "general medicine and trauma", and 401 users of medical services who attended a clinic Osteopathic located in the city of Barcelona. The clinical benefit of treatment and improving the economic cost medium and long term was found. It was established that the Spanish healthcare system does not guarantee savings for the treatment of conditions that Osteopathy treats effectively, that on the contrary, it generates more costs. Osteopathy reduces healthcare costs. / La Osteopatía ha ganado reconocimiento dentro del ámbito de la medicina y la fisioterapia. Su reconocimiento dentro de la sociedad ha propiciado que gran número de personas usen la Osteopatía como un medio para el logro de calidad de vida. El objeto del estudio fue responder al interrogante, de si es posible reducir costes sanitarios utilizando la Osteopatía para mejorar o curar dolencias relacionadas con las patologías que tienen las personas. De igual modo, evaluar la situación actual de la Osteopatía en el sistema sanitario español y proponerla como un instrumento de reducción de costes sanitarios. Mediante una revisión sistemática de literatura se obtuvieron datos que arrojaron información vinculada al objeto de investigación. Al mismo tiempo se desarrolló un trabajo de campo de tipo no experimental con el fin de determinar la ventaja relativa a la implementación de la Osteopatía para reducir costes de la salud pública. Para llegar a conclusiones ciertas, fue preciso desarrollar un trabajo de estudio, que contempló la aplicación de encuestas sobre 401 profesionales médicos de la sanidad encuadrados dentro de la “medicina general y traumatólogos”, y sobre 401 usuarios de servicios médicos que asistieron a una Clínica Osteopática ubicada en la ciudad de Barcelona. Se comprobó el beneficio clínico del tratamiento y mejora del coste económico a medio y largo plazo. Se estableció que el sistema sanitario español no garantiza ahorro para el tratamiento de patologías que la Osteopatía trata, efectivamente, que al contrario, genera más costes. La Osteopatía es generadora de reducción de costes sanitarios / L'Osteopatia ha guanyat reconeixement dins l'àmbit de la medicina i la fisioteràpia. El seu reconeixement dins de la societat ha propiciat que gran nombre de persones facin servir l'Osteopatia com un mitjà per a l'assoliment de qualitat de vida. L'objecte de l'estudi va ser respondre a l'interrogant, de si és possible reduir costos sanitaris utilitzant l'Osteopatia per millorar o curar malalties relacionades amb les patologies que tenen les persones. De la mateixa manera, avaluar la situació actual de l'Osteopatia en el sistema sanitari espanyol i proposar-la com un instrument de reducció de costos sanitaris. Mitjançant una revisió sistemàtica de literatura es van obtenir dades que van llançar informació vinculada a l'objecte d'investigació. Alhora es va desenvolupar un treball de camp de tipus no experimental amb la finalitat de determinar l'avantatge relativa a la implementació de l'Osteopatia per reduir costos de la salut pública. Per arribar a conclusions certes, va caldre desenvolupar un treball d'estudi, que va contemplar l'aplicació d'enquestes sobre 401 professionals mèdics de la sanitat enquadrats dins de la "medicina general i traumatòlegs", i sobre 401 usuaris de serveis mèdics que van assistir a una Clínica Osteopàtica ubicada a la ciutat de Barcelona. Es va comprovar el benefici clínic del tractament i millora del cost econòmic a mitjà i llarg termini. Es va establir que el sistema sanitari espanyol no garanteix estalvi per al tractament de patologies que l'Osteopatia tracta efectivament, que al contrari, genera més costos. L'Osteopatia és generadora de reducció de costos sanitaris.
383

Estudio del fármaco CMP Forte y del nucleótido UTP en células de Schwann

Martiáñez Canales, Tània 16 December 2011 (has links)
Las neuropatías periféricas representan una de las mayores complicaciones del SNP. Pocos son los fármacos efectivos para su tratamiento y la mayoría se basan en el tratamiento del dolor. Núcleo CMP Forte® es un fármaco compuesto por los nucleótidos (UMP, UDP, UTP y CMP) que se prescribe a pacientes con neuropatías periféricas de diverso origen; sin embargo, se desconoce cuál es su mecanismo de acción. Los resultados de la presente tesis demuestran que la presencia de nucleótidos extracelulares en las células de Schwann provocan una reestructuración del citoesqueleto de actina y aumentos en la adhesión (N cadherina) de forma dependiente a la activación de P2YR y de tres MAPK (JNK, P38 Y ERK1/2). Como conclusión podemos decir que los efectos a través de nuc!eótidos extracelulares podrían beneficiar los procesos de migración y de adhesión en presencia de daño axonal, favoreciendo los primeros contactos intercelulares entre células de Schwann y axones antes de remielinizar y regenerar el daño provocado en el SNP. / Peripheral neuropathies represent one of the most common pathology in the PNS. Currently, there are no efficient treatments for peripheral neuropathies, and the drugs administrated are based in pain treatment. Núcleo CMP Forte® is a drug composed by the nucleotides (UMP, UDP, UTP y CMP) and is prescribed to patients with PNS neuropathies. Despite Núcleo CMP Forte® administration leads to improvement in the patients there is no information about its mechanism of action. Our results demonstrated that extracellular nucleotides change actin organization and cellular adhesion (N cadherin) in Schwann cells. They depend on UTP-induced P2YR and MAPK (ERK1/2, JNK and P38) activation. To sum up, extracellular nucleotides effects could be beneficial in migration and adhesion processes promoting the first contacts between axons and Schwann cells and improving the regeneration in the presence oxonal damage in PNS.
384

Construção de instrumento de medida do tempo de trabalho da enfermagem em Centro de Diagnóstico por Imagem / Construction of an instrument for measuring the nursing working time in a Radiology Service

Cruz, Carla Weidle Marques da 28 June 2012 (has links)
O objetivo deste estudo foi construir um instrumento para medir o tempo despendido pela equipe de enfermagem em intervenções realizadas nos setores de Tomografia Computadorizada, Ressonância Nuclear Magnética, Ultrassonografia, Mamografia e Radiologia Convencional em Centros de Diagnóstico por Imagem. Trata-se de estudo de abordagem quantitativa, observacional, transversal e descritivo, realizado em um CDI de um Hospital privado, localizado na cidade de São Paulo. Os dados foram coletados, de outubro a novembro de 2011, e organizados seguindo as etapas: (1) identificação das atividades de enfermagem nos cinco setores por meio de levantamento em revisão bibliográfica e observação em campo; (2) mapeamento das atividades identificadas em intervenções de enfermagem, conforme a Classificação das Intervenções de Enfermagem (NIC); (3) validação das intervenções de enfermagem em uma oficina de trabalho por meio da validação de conteúdo; (4) teste piloto do instrumento de medida da distribuição do tempo dos profissionais de enfermagem em CDI por meio da técnica de amostragem do trabalho, em intervalos de 10 minutos. Participaram da observação em campo e do teste piloto 17 profissionais de enfermagem. Foram relacionadas, por meio de revisão bibliográfica e observação direta, 126 atividades de enfermagem. Após o mapeamento cruzado, 54 intervenções de enfermagem corresponderam a 126 atividades. Como resultado da oficina de trabalho, os sete juízes participantes reduziram o número de intervenções para 32 e de atividades para 92. A intervenção Reunião Administrativa foi criada, pois não há intervenção na NIC que corresponda à atividade Participar de reuniões. As 92 atividades de enfermagem do instrumento corresponderam a 32 intervenções, 15 classes e sete domínios da NIC. As principais intervenções observadas nos cinco setores foram, em ordem de frequência: Assistência em Exames, Documentação, Gerenciamento de Caso, Acompanhamento por telefone, Cuidados na admissão e Troca de informações sobre cuidados de saúde. O instrumento mostrou-se adequado à realidade assistencial da equipe de enfermagem no CDI estudado. Com esta pesquisa, foi possível propor um instrumento de intervenções, fundamentado na NIC, para se obter a distribuição do tempo despendido pela equipe de enfermagem em cada intervenção nos setores de Tomografia, Ressonância Magnética, Ultrassonografia, Mamografia e Radiologia Convencional. / The purpose of this study was to build an instrument that could measure the time spent in nursing interventions performed in the CT, MRI, Ultrasound, Mammography and X-ray sectors of a radiology department. This was an observational, transversal and descriptive study with a quantitative approach. The survey was conducted in a private Radiology Service located in São Paulo, Brazil. The data was collected from October to November, 2011. The steps of the study were: (1) identification of nursing activities in each sector by direct observation and literature review; (2) cross-mapping with the NIC taxonomy; (3) face validation of interventions by nurses and technical specialists in radiology and in the use of NIC; (4) pilot testing of the instrument by using work sampling technique, in 10 minutes intervals. Seventeen nursing professionals participated in the observational and pilot testing steps of the study. 126 nursing activities were identified, based on literature review and direct observation. After the cross-mapping technique, 54 nursing interventions corresponded to the 126 activities. As a result of the workshop technique, the seven judges reduced the number of interventions to 32 and the activities to 92. The 92 nursing activities corresponded to 32 nursing interventions, 15 classes and 7 domains of the NIC. The most frequent interventions were: Examination Assistance, Documentation, Case Management, Telephone Follow-up, Admission Care and Health Care Information Exchange. The instrument was shown to be appropriated to the nursing staff reality in the Radiology Center where the study was conducted. As a result of this study, it seemed possible to propose an instrument capable of assessing the workload and information relevant to staffing, by measuring the distribution of time spent by nursing staff interventions in CT, MRI, Ultrasound, Mammography and X-ray sectors
385

Análise da imagem radiográfica de raízes apicetomizadas e irradiadas com laser de Nd:YAG por meio do processamento de imagem de radiografias digitais diretas / Radiographic image analysis of apicetomized roots irradiated with Nd:YAG laser using imaging processing of direct digital radiographs

Brucoli, Henrique Cesar Purchio 22 September 2009 (has links)
Nesta pesquisa foi realizada a análise da imagem radiográfica digital da técnica periapical de raízes cujos ápices foram irradiados com laser de Neodymium Yttrium Aluminum Garnet (Nd:YAG) após a ressecção apical. Com intuito de encontrar alterações da imagem radiográfica digital das raízes causadas pela irradiação laser, desenvolvemos um modelo experimental in vitro. Foram realizadas as apicectomias de 39 raízes de dentes unirradiculares a dois milímetros do limite apical, com posterior fixação dos dentes em dispositivo que conferiu uma rígida padronização das radiografias, cujas imagens foram capturadas por meio de um sistema de radiografia digital direta (Dixi® Planmeca). Com a fixação das raízes no dispositivo de padronização, realizamos uma radiografia inicial, irradiamos os ápices radiculares com o laser de Nd:YAG e em seguida fizemos uma radiografia final, sem manipulação do sistema de padronização durante todo o processo. Os parâmetros de irradiação laser utilizados foram baseados no protocolo de pesquisa clínica para cirurgias apicais desenvolvido no Laboratório Especial de Laser em Odontologia (LELO-FOUSP). Foram eles 100mJ, 15Hz, 1,5W e diâmetro da fibra óptica de 320m. As radiografias foram obtidas com três tempos de exposição diferentes (0,05s, 0,08s e 0,14s). As imagens radiográficas antes e depois a irradiação laser, obtidas em 12 bits, foram convertidas para 8 bits e exportadas para o programa de análise de imagens ImageTool 3.0.0. A análise das imagens digitais foi executada por meio de histogramas e subtração de imagem digital quantitativa. Foi possível detectar por meio dos dois métodos uma menor quantidade de dentina na superfície apical após a irradiação com o laser de Nd:YAG. A variável tempo de exposição não apresentou diferenças estatísticas significantes, porém foi observada uma tendência de melhor desempenho dos métodos com imagens obtidas com exposição de 0,05s. Apesar de termos observado remoção de tecido dentinário, não foi possível detectar a presença de uma camada de dentina mais radiopaca nas imagens radiográficas da superfície irradiada. / In this research, we carried out an evaluation of the digital radiographic image of dental root-ends irradiated with Neodymium Yttrium Aluminum Garnet (Nd:YAG) laser after apical resection. With the intention of founding alterations in the digital radiographic image of the roots caused by laser irradiation, we developed an in vitro experimental model. We made apicectomy in 39 single-root teeth, 2 milimeters below the apical limit and then we fixed these teeth in a standardization device. The radiographic images were captured thru a direct digital radiographic system (Dixi® Planmeca). After positioning of the teeth in the standardization device, we made an initial radiograph, Nd:YAG laser irradiation of the apex and a final radiograph, without manipulation of the standardized system during the whole process. The laser parameters applied in this research followed the clinical research protocol for apical surgeries developed in the LELO- FOUSP. They were 100mJ, 15Hz, 1,5W and a 320m diameter optic fiber. The radiographs were made within three different exposure times (0,05s, 0,08s and 0,14s). The obtained 12 bit radiographic images before and after laser irradiation were converted to 8 bit images and exported to the ImageTool 3.0.0 image analysis software. With this software wee analyzed the digital images in the methods of histogram analysis and quantitative digital image subtraction. The two methods indicated less amount of dentin in the apical surface after Nd:YAG laser irradiation. The variable exposure time did not present statistical differences. However, we observed a tendency of better performance of the methods with images obtained with 0,05s exposure time. Although we observed dental tissue ablation, it was not possible to detect the presence of a more radiopac dentin layer in the irradiated surface radiographic images.
386

Estudo longitudinal da densidade mineral óssea de cães normais, portadores e afetados pela distrofia muscular do Golden Retriever (D.M.G.R.) / Longitudinal study of bone mineral density in healthy, carrier, and affected dogs by Golden Retriver Muscular Dystrophy (G.R.M.D.)

Giglio, Robson Fortes 24 September 2004 (has links)
A forma mais comum de distrofia muscular em humanos é do tipo Duchenne, com uma incidência aproximada de um caso a cada 3.500 nascimentos masculinos. A Distrofia Muscular do Golden Retriever (DMGR) é considerada o modelo animal mais apropriado à Distrofia Muscular de Duchenne (DMD). A Densitometria Óptica Radiográfica é um método de análise para quantificação da matéria mineral óssea, sendo, neste estudo, realizado com radiografias simples da tíbia direita ao lado de escala de alumínio. Foram utilizados 15 cães da raça Golden Retriever, sendo 5 cães normais, 5 fêmeas portadoras e 5 machos afetados pela DMGR, que foram radiografados mensalmente, dos 3 aos 9 meses de idade. Estas radiografias foram digitalizadas e analisadas por meio de um software de análise de imagens (ImageLab, Softium®), que compara as tonalidades de cinza da escala com região óssea analisada, obtendo-se valores em milímetros de alumínio (mmAl). Os resultados obtidos foram analisados estatisticamente utilizando o procedimento Proc Means do programa Statistical Analysis System, versão 8.0. O estudo revelou que a região epifisária possui maior densidade mineral óssea (DMO), seguida pela região metafisária e diafisária, respectivamente, nos três grupos avaliados, ao longo do período experimental, e seguiram o comportamento do peso corpóreo. Houve uma tendência de aumento da DMO nas três regiões avaliadas dos três grupos ao longo do experimento. A região metafisária proximal de tíbia demonstrou ser a região de eleição para a leitura da DMO por ser o local estudado com menor correlação com o peso corpóreo e por promover estimativas médias consideradas significativas entre grupos avaliados mais cedo que nas demais regiões O potencial de diagnóstico do exame densitométrico, em relação a DMGR, foi considerado baixo, entretanto demonstrou ter grande potencial no acompanhamento do progresso desta doença por apresentar alta sensibilidade para detecção de variações na densidade mineral óssea. / Duchenne Muscular Dystrophy is the most common type of muscular dystrophy in humans affecting 1 in 3,500 male births. Muscular dystrophy in Golden Retrievers appears to be an appropiate model of the human Duchenne Muscular Dystrophy. Radiographic Optical Densitometry is an analitic method to meansure bone mineral content. This technique was performed by right tíbia simple radiograph conjugated with an aluminium stepwedge. 5 helthy dogs, 5 female carriers and 5 male affected dogs by Golden Retriever Muscular Dystrophy were divided in 3 groups. Monthly, all the dogs were radiographed from 3-mouths until 9-mouths old. Radiographs were digitalized and analyzed by an image processing software (ImageLab, Softium), which compares the aluminium grey scale tonalities with a bone region analyzed obtaining with this the value of bone mineral density in aluminium milimeters (mmAl). The obtained results were statistically analyzed using the the procedure Proc Means of the program Statistical Analysis System 8.0 software. The epifisary region possess higher bone mineral density followed for the metafisary and diafisary regions, respectively, in the three evaluated groups during the experimental period and followed by the behavior of the corporeal weight. There was a trend of increase of the bone mineral density in the three evaluated regions of all three groups. The proximal metafisary region of tíbia demonstrated to be the best region of selection to evaluate the bone mineral density since it is place studied with less correlation with the corporeal weight and by promoting significant considered average estimates between groups evaluated earlier than other regions. The potential of diagnosis of this densitometric method in Golden Retriever Muscular Dystrophy was considered low, however this study demonstrated to have great potential in the accompanying the progress of this disease due to the high sensitivity for detection of bone mineral density changes.
387

Radiologia convencional e tomografia computadorizada na avaliação de cães portadores de discopatia torácica, toracolombar, lombar ou lombosacra: estudo comparativo / Radiographic and tomographic exams in the evaluation of dogs with disease in thoracic, thoracolumbar, lumbar or lumbosacral spine: a comparative study

Santos, Iara Levino dos 01 September 2006 (has links)
Foram avaliados 58 cães portadores de discopatia nos segmentos torácico, toracolombar, lombar ou lombosacro da coluna vertebral pelos exames radiográficos simples, contrastado (mielografia) e pela tomografia computadorizada (TC). Os animais com padrão de raça definido foram os mais acometidos (88%), sendo a raça Dachshund com maior representatividade (48%). A faixa etária mais acometida foi entre 4-7 anos de idade (48%). O exame radiográfico simples detectou aspectos radiográficos compatíveis com extrusão em 29 observações. A mielografia diagnosticou 98 protrusões, 43 extrusões e 10 hérnias de disco, além de fornecer informações relativas ao grau de comprometimento medular. A TC diagnosticou 84 observações de protrusões, 48 extrusões e 2 hérnias de disco. Os espaços mais comprometidos pela extrusão diagnosticados pelos métodos empregados foram T12-13, T13-L1 e T11-12. A TC esclareceu as dúvidas sugeridas pela mielografia, embora também apresentou limitações quando a compressão medular não apresentou a presença de material hiperatenuante. Nos casos com interrupção da coluna de contraste a TC foi capaz de detectar a extrusão devido à presença de material hiperatenuante em canal medular. Os métodos de diagnóstico por imagem empregados foram complementares e forneceram informações importantes para o prognóstico desses animais. / Disc disease in thoracic, thoracolumbar, lumbar or lumbosacral spine hás been evaluated in 58 dogs by survey radiography, mielography and computed tomography. The disc disease infrequently occurs in mixed-breed dogs; Dachshunds werw at higher risk for disc disease than other breeds (48%. Most dogs are between 4-7 years of age (48%). The survey radiography showed 29 observations of extrusions. The mielography showed 98 protrusions, 43 extrusions and 10 disc herniated. The CT showed 84 protrusions, 48 extrusions and 2 disc herniated. The affected disc spaces by extrusion seen in this study were T12-13, T13-L1 and T11-12. The mielography releasedsomo doubts, that have been resolved by CT; howeverthe CT showed doubts when there wasn´t soft-tissue mineralization in vertebral canal. When thre was a complete blockage of contraste because of contrast material the CT diagnoses the disc lesion because the presence of soft tissue mineralization vertebral canal. The methods of imaging diagnosis used complete each other and provided important information used to assess prognosis of the affected animals.
388

Estudo do retalho nasosseptal para reconstrução endoscópica da base do crânio anterior / Study of the nasosseptal flap for endoscopic skull base reconstruction of the anterior cranial base

Pinheiro Neto, Carlos Diógenes 31 August 2011 (has links)
Introdução: O uso do retalho nasosseptal (NS) para a reconstrução endoscópica da base do crânio foi fator fundamental para o avanço dos acessos endonasais expandidos. Objetivos: Aferir as dimensões do retalho NS e do defeito da base do crânio anterior (BCA) após ressecção craniofacial endoscópica e verificar a suficiência do retalho para cobrir o defeito. Estudar a anatomia da artéria septal (AS) e sua relação com o óstio do seio esfenoide. Métodos: Estudo anatômico do retalho NS em 14 cadáveres. Após ressecção craniofacial endoscópica, foi verificado a suficiência do retalho em cobrir o defeito na BCA. A AS foi dissecada e estuda quanto ao número de ramos presentes no pedículo e sua distância em relação ao óstio do seio esfenoide. Estudo radiológico com tomografia computadorizada de 30 pacientes para a comparação entre medidas do retalho NS e as do defeito na BCA. Resultados: O retalho foi suficiente para cobrir o defeito na BCA nas 14 dissecções. Em 71,4% dos casos, dois ramos da AS foram encontrados no pedículo. A distância média entre o primeiro ou único ramo ao óstio do esfenoide foi de 9,3mm. No estudo radiológico, a média da área reconstrutora do retalho (17,12cm2) foi constantemente maior que a média da área do defeito (8,64cm2) (p<0,001). A diferença entre o comprimento superior do retalho e a distância anteroposterior do defeito foi menor ou igual a 5mm em 26,7% dos casos. A comparação entre a largura anterior do retalho e a distância interorbitária anterior revelou que em 33% dos casos a diferença foi 5mm. A incorporação da mucosa do assoalho da fossa nasal ao retalho aumentou essa diferença em mais 10mm em todos os casos. Conclusões: As dimensões do retalho NS são suficientes para cobrir o defeito na BCA. A extremidade anterior do comprimento anteroposterior do defeito apresenta maior risco de falha de cobertura. A incorporação da mucosa do assoalho da fossa nasal ao retalho é importante para diminuir o risco de falha de cobertura anterior na largura do defeito. Em geral, é mais comum a presença de dois ramos da AS no pedículo / Introduction: Use of the nasoseptal (NS) flap for endoscopic skull base reconstruction was an essential contribution for the evolution of the expanded endonasal approaches. Objectives: Measure the dimensions of the NS flap and the anterior skull base (ASB) defect after endoscopic craniofacial resection and verify if the flap is sufficient to cover the defect. Study the anatomy of the septal artery (SA) and its relation with the sphenoid ostium. Methods: Anatomical study of the NS flap in 14 cadavers. After endoscopic craniofacial resection, the sufficiency of the flap to cover the ASB defect was assessed. The SA was dissected and studied regarding the number of branches in the pedicle and the distance between the artery and the sphenoid ostium. Radiological study using CT scans of 30 patients for comparison among measurements of the NS flap and the ASB defect. Results: The flap was sufficient to cover the ASB in all 14 dissections. In 71.4% of the cases, 2 branches of the SA were found in the pedicle. The distance between the first or the only single branch of the SA to the sphenoid ostium was 9.3mm. In the radiological study, the reconstruction area of the flap (17.12cm2) was constantly larger than the defect area (8.64cm2) (p<0.001). The difference between the superior length of the flap and the anterior-posterior distance of the defect was 5mm in 26.7% of the cases. Comparison between the flap anterior width and the defect anterior width revealed that in 33% the difference was 5mm. The incorporation of the nasal floor mucosa to the flap increased that difference in more than 10mm in all cases. Conclusions: The dimensions of the NS flap are sufficient to cover completely the ASB defect. The anterior edge of the anterior-posterior length of the defect presents increased risk for failure in coverage. The additional width provided by the incorporation of the nasal floor mucosa to the flap is important to decrease the risk of failure in coverage of the anterior defect width. In general, it is more common to find 2 branches of the SA in the pedicle
389

Espectroscopia de raios X utilizando o espalhamento Compton / X-ray spectroscopy using compton scattering

Linke, Arlene 16 September 2008 (has links)
O estudo do espectro de raios X é importante para predizer a qualidade da imagem em sistemas radiográficos. Nesse trabalho usamos um detector semicondutor CdTe para medir os espectros de raios X na faixa de 25 a 120 kVp. Esse detector é pequeno e fácil de ser transportado. As medidas feitas diretamente do tubo de raios X não são aconselháveis devido à alta taxa de fluência que estão acima dos limites de detecção dos detectores usuais e podem causar armadilhamento de carga no detector CdTe. A alternativa é medir os fótons espalhados a 900 a partir de um pequeno objeto espalhador, no nosso caso um cilindro de lucite (PMMA). A partir do espectro espalhado, corrigido para tempo morto e eficiência, e calibrado em energia, efetuamos correções para o ângulo de espalhamento e espalhamento coerente (somente para baixas energias). Só então formalismo de Klein-Nishina para as seções de choque do efeito Compton é aplicado aos espectros, resultando nos espectros primários. Para energia de 120 kVp foi medido um espectro do feixe direto e comparado com o obtido através do espectro espalhado para mesma energia. Para o mesmo feixe, a camada semi-redutora foi avaliada experimentalmente e com o espectro obtido por espalhamento Compton, obtendo-se boa concordância. Observamos na curva de eficiência uma descontinuidade, prevista teoricamente e também observada por outros autores, que deforma o espectro corrigido. Foi aplicado um ajuste polinomial a essa curva, suavizando os espectros obtidos e não alterando sua forma. Os resultados foram satisfatórios e validaram o formalismo apresentado por outros autores, utilizando detectores distintos. / The analysis of x-ray spectra is important to predict image quality in radiographic systems. In this work we used a semiconductor CdTe detector to measure x-ray spectra with a CdTe detector, in the range from 25 to 120 kVp. The CdTe detector is small and portable. The measurements done directly in the primary X rays beam can be difficult because of the high photon fluence rates that cause significant detector photon pile up, and can cause charge trapping in the CdTe. The alternative is to measure the photons scattered at 900 by a small scattering object, in our case a Lucite cylinder (PMMA). Starting from the scattered spectrum, corrected to dead time and efficiency and calibrated in energy, we made corrections for the scattering angle and coherent scattering (only at low energies). After that, the Klein Nishina cross section for Compton scattering are applied to the spectra, resulting in the primary spectra. For the 120 kVp beam a spectrum of the direct beam was measured and compared to the one obtained it through the scattered spectrum for the same energy. The half value layer of the same spectrum was determined experimentally and through the calculated spectrum, and the agreement was very good. The efficiency curve presents a discontinuity, also observed by other authors and predicted theoretically, that deforms the corrected spectrum. A polynomial fitting was adjusted to the efficiency curve, smoothing the corrected spectra without and not altering its form. The results were satisfactory and they validated the methodology presented by other authors, using different detectors.
390

Dosimetria em tomografia computadorizada de feixe cônico odontológica / Dental Cone Beam Computed Tomography Dosimetry

Mauro, Rodrigo Antonio Pereira 13 June 2017 (has links)
Os objetivos deste trabalho foram caracterizar os níveis de referência de radiodiagnóstico para a tomografia computadorizada de feixe cônico odontológica e as características de desempenho dos equipamentos como quilovoltaqgem de pico, rendimento, camada semirredutora, etc., com o intuito de conhecer os níveis dosimétricos em que os pacientes estão expostos, permitindo assim identificar protocolos de aquisição de imagem mais adequados, levando-se em consideração os princípios de radioproteção, e também testar a capacidade de tais equipamentos em alcançar uma imagem de qualidade. A Cone Beam Computed Tomography tem se tornado ferramenta extremamente útil na utilização em procedimentos radiológicos na área odontológica, pois, a riqueza de informações que a imagem 3D trás para o planejamento cirúrgico ou em qualquer procedimento, minimiza as possibilidades de erros, possibilita diagnósticos mais confiáveis e claros, tendo influência direta no resultado final esperado pelo paciente. Por se tratar de uma técnica de imagem que utiliza radiação ionizante, deve-se ter uma atenção criteriosa voltada para os níveis de radiação, além de implementar uma rotina de controle de qualidade. O parâmetro dosimétrico mais utilizado em tomografia computadorizada é o Computed Tomography Dose Index, porém, quando aplicado à tomografia odontológica, a geometria cônica do feixe e ainda a extensão do campo de visão tornam essa grandeza inviável e enganosa, assim, faz-se necessária a padronização de uma grandeza dosimétrica mais otimizada, para evitar a subestimação dos níveis de dose em feixes de ampla abrangência. O PKA tem sido utilizado como uma possível grandeza dosimétrica em tomografia odontológica, uma vez que em sua metodologia de medida, todo o feixe é englobado pelo medidor, não depende da distância fonte - detector, além de ser sensível aos parâmetros de exposição. Diante disso, propõe-se o PKA ser utilizado para estabelecimento dos níveis de dose de referência em diagnóstico odontológico. Os valores PKA obtidos para este estudo estão em uma faixa entre 34,6 mGy.cm^2 e 2901,6 mGy.cm^2, com valor médio de 980,7 mGy.cm^2. Os valores encontrados para os níveis de referência de radiodiagnóstico calculados a partir do 3º quartil estão divididos em três classes referentes ao tamanho do campo de visão, onde para campos pequenos, médios e grandes os valores são 1241 mGy.cm^2, 1521 mGy.cm^2 e 1408 mGy.cm^2 respectivamente, e 1446 mGy.cm^2 é o valor global independente do campo de visão. Os testes de controle de qualidade foram todos positivos, com uma atenção para o i-CAT FLX, que excedeu levemente o limite aceitável para a exatidão do kVp. Uma comparação entre CTDI100 e CTDI300, reportou que o CTDI300 é em média 49% maior em relação ao CTI100. Os níveis de referência de radiodiagnóstico são representativos dos níveis de dose otimizados, e servem como base para adequação e otimização dos parâmetros de exposição do equipamento. Os testes de controle de qualidade alertam para possíveis irregularidades no funcionamento do tomógrafo, e deve complementar obrigatoriamente a rotina dos procedimentos clínicos. / The objectives of this study are to characterize the radiodiagnostic reference levels for computed tomography of dental cones and as performance characteristics of equipment such as peak kyvoltage, yield, semi-reducing layer, etc., in order to know the levels of the values in that users are exposed, thus allowing to identify more adequate image acquisition protocols, taking in basic concepts of radioprotection, and also to test the capacity of such equipment in a quality image. The Cone Beam CT scan has become active, useful in medical, medical, dental, on the Internet, in any situation, minimizes as possibilities of errors, allows for more reliable and clear diagnoses, having a direct influence on the final result expected by the patient. Because it is an imaging technique that uses ionizing radiation, careful attention should be given to radiation levels, in addition to implementing a quality control routine. The dosimetric parameter most commonly used in computed tomography is the Computed tomography dose index, however, when applied to dental tomography, the conic geometry of the beam and still the extension of the field of view make this greatness unfeasible and deceptive, so it is done The. standardization of a more optimized dosimetric quantity, to avoid an underestimation of the dose levels in beams of wide range. The PKA has been used as a possible dosimetric magnitude in dental tomography, since in its measurement methodology, the whole beam is encompassed by the meter, it does not depend on the source - detector distance, besides being sensitive to the exposure parameters. Therefore, it is proposed that PKA be used for the establishment of reference dose levels in dental diagnosis. The PKA values obtained for this study ranged from 34.6 mGy.cm^2 to 2901.6 mGy.cm^2, with a mean value of 980.7 mGy.cm^2. The values found for the levels of radiodiagnostic reference values calculated from the 3rd quartile are divided into three classes referring to the size of the field of vision, where for small, medium and large fields are the values are 1241 mGy.cm^2, 1521 mGy.cm^2 and 1408 mGy.cm^2 respectively, and 1446 mGy.cm^2 is the global independent value of the field of view. The quality control tests were all positive, with an attention to the i-CAT FLX, which slightly exceeded the acceptable limit for kVp accuracy. A face between CTDI100 and CTDI300, reported that the CTDI300 is on average 49% higher than the CTI100. Radiodiagnostic reference levels are representative of optimized dose levels and serve as a basis for adequacy and optimization of the exposure parameters of the equipment. The quality control tests alert to possible irregularities in the operation of the tomograph, and develop properly from the clinical process.

Page generated in 0.1838 seconds