• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 43
  • 39
  • 4
  • 3
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 260
  • 57
  • 55
  • 53
  • 42
  • 42
  • 41
  • 38
  • 38
  • 37
  • 32
  • 28
  • 27
  • 26
  • 25
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
191

Estudo da degradação de reagentes liofilizados para radiodiagnóstico por cromatografia líquida de alta eficiência (HPLC) e espectrometria de massas (MS) / Study of degradation of lyophilized reagents for radiodiagnosis by high performance liquid chromatography (HPLC) and mass spectrometry (MS)

Érika Vieira de Almeida 27 August 2015 (has links)
A utilização de radiofármacos no diagnóstico de doenças do organismo humano tem aumentado de forma significativa nas últimas décadas. O crescente desenvolvimento de novos reagentes liofilizados (RL) para a preparação de radiofármacos, embora proporcionem uma maior variedade para o mercado de radiofármacos, deixa evidente uma das lacunas na pesquisa radiofarmacêutica: a identificação de produtos de degradação. No presente trabalho, foram identificados os principais produtos de degradação dos RL de ácido 2,3-Dimercaptosuccínico (DMSA) e Etilenodicisteína Dietil Éster (ECD) utilizando as técnicas de cromatografia líquida de alta eficiência com Detecção por Arranjo de Diodos (HPLC-DAD) e cromatografia líquida acoplada à espectrometria de massas de múltiplos estágios (LC-MSn). Realizou-se o estudo de degradação forçada do RL de DMSA e do RL de ECD nas condições de estresse hidrolítico, fotolítico, oxidativo e termodegradação. As análises foram realizadas em equipamento HPLC-DAD Shimadzu e espectrômetro de massas Bruker Daltonics. Todas as análises foram desenvolvidas utilizando coluna cromatográfica Shim-Pack VP-ODS (150 mm x 4,6 mm; 5 μm). O DMSA apresentou tempo de retenção de 5,58 minutos e m/z 204,8. A hidrólise ácida do DMSA não apresentou produtos de degradação. O perfil de degradação do DMSA após hidrólise alcalina apresentou três picos cromatográficos com características mais apolares que o DMSA. No espectro de fragmentação do íon de m/z 204,8 (MS2) pode-se observar a presença do fragmento de m/z 172,9, correspondente ao aduto sodiado de ácido mercaptosuccínico (MSA); e o fragmento de m/z 139,0 (MS3), correspondente ao aduto sodiado do ácido fumárico. O íon estanho (Sn) apresentou-se coordenado ao DMSA em todos os produtos de degradação após hidrólise alcalina do RL de DMSA. As amostras submetidas à hidrólise neutra não apresentaram degradação. Nos estudos de fotólise do DMSA, o íon de m/z 267,1 pode ser identificado como o ácido diacetil dimercaptosuccínico (BATSA). O íon de m/z 127,1 foi associado ao ácido hidroximetil fosfônico e observado nos estudos de oxidação. A termodegradação do DMSA e do RL de DMSA, não apresentou uma relação de decaimento da concentração do DMSA em função do tempo. Quanto ao RL de ECD, foi observado o ECD protonado em 5,55 minutos (m/z 325,6). As análises por LC-MSn do ECD sob hidrólise alcalina mostraram que o pico com tempo de retenção de 1,71 minutos foi identificado como o íon protonado do EC ([M+H]+) em m/z 269,2. Os picos com tempo de retenção de 3,34 e 3,69 minutos foram identificados como o íon protonado do ECD na forma monoéster (ECDM). A degradação alcalina do RL de ECD apresentou os íons de m/z 441,9 (ECD-Sn) e m/z 737,9 ([ECD2+Sn]-C2H2-2H). ECD monoester monoácida (ECDM) de m/z 295,2; ECD oxidado de m/z 323,5; ECD oxidado com duas pontes dissulfeto de m/z 389,1 e dímero de ECD de m/z 645,9 foram observados da degradação oxidativa. Conclui-se que as análises por HPLC-DAD e LC-MSn podem ser utilizadas no estudo de estabilidade de RL, identificando suas impurezas e produtos de degradação. / The use of radiopharmaceuticals in the diagnosis of diseases of the human organism has increased significantly in the last decades. The increasing development of new lyophilized reagents (LR) for the preparation of radiopharmaceuticals, although providing a greater variety of radiopharmaceuticals to the market, makes evident a gap in the radiopharmaceutical research: identification of degradation products. In the present work, the main degradation products of the 2,3-Dimercaptosuccinic acid (DMSA) and Ethylenedicysteine Diethyl Ester (ECD) LR were identified, using the techniques of high performance liquid chromatography with diode array detection (HPLC -DAD) and liquid chromatography multiple-stage mass spectrometry (LC-MSn). The study of forced degradation of DMSA and ECD LR was performed in the hydrolytic, photolytic and oxidative stress conditions and thermodegradation. Analyses were performed using an HPLC-DAD Shimadzu and mass spectrometer Bruker Daltonics equipment. All analyzes were carried out using Shim-Pack VP-ODS (150 mm x 4.6 mm; 5 μm) chromatographic column. DMSA showed a retention time of 5.58 minutes and m/z 204.8. Acid hydrolysis of DMSA showed no degradation products. The degradation profile of DMSA after alkaline hydrolysis presented three chromatographic peaks with more nonpolar characteristics than DMSA. In the fragmentation spectrum of the ion m/z 204.8 (MS2), the presence of a fragment of m/z 172.9 was observed, corresponding to sodium adduct of mercaptosuccinic acid (MSA); and a fragment of m/z 139.0 (MS3), corresponding to sodium adduct of fumaric acid. The tin ion was coordinated to DMSA in all degradation products after alkaline hydrolysis of DMSA LR. The samples submitted to neutral hydrolysis showed no degradation. In the studies of photolysis of DMSA, the ion m/z 267.1 can be related to diacetyl dimercaptosuccinic acid (BATSA). The ion of m/z 127.1 observed in the studies of oxidation can be related to phosphonic hydroxymethyl acid. The thermodegradation of DMSA and its LR did not show a relationship between the decrease in the DMSA concentration and the time. The protonated ECD was observed in 5.55 minutes (m/z 325.6). Analysis by LC-MSn of ECD under alkaline hydrolysis showed that the peak with retention time of 1.71 minutes could be identified as the protonated ion of EC ([M+H]+) at m/z 269.2. The peaks with retention times of 3.34 and 3.69 minutes were identified as the protonated ion of ECD in its monoester form (ECDM). The alkaline degradation of ECD LR presented the m/z 441.9 (ECD-Sn) and m/z 737.9 ([ECD2+Sn]-C2H2-2H) ions. ECD monoester monoacid (ECDM) of m/z 295.2; ECD oxidized of m/z 323.5; ECD oxidized with two disulfide bonds of m/z 389.1 and ECD dimer of m/z 645.9 were observed in the oxidative degradation. It was concluded that the analysis by HPLC-DAD and LC-MSn can be used in the stability of LR, identifying and quantifying its impurities and degradation products.
192

Atividades de radioisótopos administradas em Medicina Nuclear e proposta de nível de referência em diagnóstico (DRL) para o Brasil / Administered radioisotope activities in Nuclear Medicine and a proposal of diagnostic reference level (DRL) to Brasil

Braga, Luis Felipe Emanuel Faleiros 14 October 2016 (has links)
Estima-se que o número de exames diagnósticos em Medicina Nuclear cresça a uma taxa de 5% ao ano, ocasionando aumento das exposições de pacientes, familiares e meio ambiente às radiações ionizantes. O intuito dos guias de referência em exames diagnósticos (DRL) é a padronização das técnicas e a diminuição das exposições ao mínimo possível e estritamente necessárias para a realização do exame médico, todavia, a área de Medicina Nuclear brasileira não possui este tipo de guia, favorecendo o descontrole das exposições e incremento de riscos associados. O principal objetivo deste estudo foi a elaboração de um DRL para a área de Medicina Nuclear com base nos tipos de exames, atividades administradas, técnicas adotadas e parque de equipamentos disponíveis no país. Formulários foram enviados para todos os Serviços de Medicina Nuclear do Brasil - SMNs (~430) visando obter essas informações, bem como os tipos de ajustes das atividades de acordo com a idade e o peso corpóreo dos pacientes. Os dados foram analisados e como proposta de DRL, considerou-se o valor do percentil 75 (P75) da atividade máxima administrada em cada exame. Um total de 107 SMNs, representando 14 estados brasileiros e o Distrito Federal, responderam ao questionário. Dos 64 diferentes procedimentos diagnósticos analisados, as cintilografias óssea, renal e paratireoide são disponibilizadas em mais de 85% de todos os SMNs analisados. As atividades administradas para um mesmo tipo de exame apresentaram uma alta taxa de dispersão, alcançando diferenças superiores a 20 vezes entre o menor e maior valor praticado. Exames diagnósticos envolvendo os radioisótopos 67Ga, 201Tl e 131I foram observados como os geradores de maior dose de radiação aos pacientes. O ajuste das atividades para pacientes pediátricos tem levado em consideração a regra de Webster, regra de três simples e ajustes empíricos de acordo com o peso corpóreo dos pacientes. Com a aplicação dos valores de atividade propostos como DRL na rotina clínica, pode-se alcançar uma redução mínima de 15%, máxima de 95% e média de 50% em relação às atividades atualmente aplicadas. Ao todo, foram encontrados 189 equipamentos de imagem em funcionamento, sendo principalmente de quatro fabricantes diferentes (Elscint, GE, Philips e Siemens). A variabilidade das atividades administradas para um mesmo tipo de exame, respeitando as diferenças tecnológicas, pode refletir a falta de controle das exposições à radiação e a inexistência de um guia de referência nacional para a área de Medicina Nuclear, assim como também exemplificar a diversidade de protocolos de imagem praticados no país. A adoção de um DRL para a área de Medicina Nuclear poderia contribuir consideravelmente para o controle das exposições e padronização da técnica, ofertando à população exames de alta tecnologia e de riscos controlados / It has been estimated that the number of diagnostic procedures in Nuclear Medicine has shown an annual growth rate of 5%, and consequently increasing the ionizing radiation exposition of patients, family and environment. The aim of diagnostic reference levels (DRL) is the standardization of techniques and decrease expositions to as low as possible and just compatible with the diagnostic exam under study. However, Brazilian Nuclear Medicine does not have those references, causing a decontrol of expositions and increasing the associated risks. The main objective of this study was the DRL development to Nuclear Medicine on the basis of diagnostic procedures, administered activities, adopted techniques, and the available equipments in the country. Forms were sent to all the Brazilian Nuclear Medicine Services -NMS (~430) aiming to obtain those information, as well as the rules applied to adjust the administered activities according to patient\'s age and body mass. All data were analyzed, and the percentile 75 (P75) of the maximum activity applied in each diagnostic exam was considered as the DRL. A total of 107 NMS have answered the form, representing 14 Brazilian states and Federal District. From the 64 diagnostic procedures studied, bone, kidney and parathyroid scintigraphy were found to be used in more than 85% of all the NMS analyzed. There was a large disparity among the activities administered, when applying the same procedure, reaching, in some cases, more than 20 times between the lowest and highest. Diagnostic exams based on 67Ga, 201Tl, and 131I radioisotopes proved to be de major exams administering radiation doses to patients. The activities adjustment to pediatric patients has used different rules, including Webster rule, rule of three and empirical adjustments according to the patient\'s body weight. On introducing the DRL activity values into clinical routine, the minimum reduction in radiation doses received by patients was about 15%, the maximum was 95%, and the average was 50% compared with the previously reported administered activities. There were found 189 image equipments working, with mainly 4 different brands (Elscint, GE, Philips e Siemens). The variability in the administered activities to the same diagnostic procedure, respecting the existing differences in technology, may reflect the lack of radiation exposition control and the non-existence of a national reference guide to Nuclear Medicine, as well as exemplify the variability in the image protocols practiced in the country. The establishment of DRL to a Nuclear Medicine could considerably contribute toward the control and reduction of radiation exposure, thereby offering to the public high-technology exams with controlled risks
193

Estudo do pior caso na validação de limpeza de equipamentos de produção de radiofármacos de reagentes liofilizados. Validação de metodologia de carbono orgânico total / Worst-case study for cleaning validation of equipments in the radiopharmaceutical production of lyophilized reagents. Metodology validation of total organic carbon.

Porto, Luciana Valeria Ferrari Machado 18 December 2015 (has links)
Os radiofármacos são definidos como preparações farmacêuticas contendo um radionuclídeo em sua composição, são administrados intravenosamente em sua maioria, e, portanto, o cumprimento dos princípios de Boas Práticas de Fabricação (BPF) é essencial e indispensável à tais produtos. A validação de limpeza é um requisito das BPF e consiste na evidência documentada que demonstra que os procedimentos de limpeza removem os resíduos a níveis pré-determinados de aceitação, garantindo que não haja contaminação cruzada. Uma simplificação da validação dos processos de limpeza é admitida, e consiste na escolha de um produto, denominado de \"pior caso\" ou worst case, para representar a limpeza de todos os equipamentos da mesma linha de produção. Uma das etapas da validação de limpeza é o estabelecimento e validação do método analítico para quantificação do resíduo. O objetivo deste estudo foi estabelecer o pior caso para a validação de limpeza dos equipamentos de produção de reagentes liofilizados-RL para marcação com 99mTc, avaliar a utilização do teor de carbono orgânico total (COT) como indicador de limpeza dos equipamentos utilizados na fabricação dos RL, validar o método para determinação de CONP (carbono orgânico não purgável/volátil) e realizar testes de recuperação com o produto escolhido como pior caso. A escolha do produto pior caso baseou-se no cálculo de um índice denominado \"índice para pior caso - Worst Case Index (WCI)\", utilizando informações de solubilidade dos fármacos, dificuldade de limpeza dos equipamentos e taxa de ocupação dos produtos na linha de produção. O produto indicado como pior caso entre os RL foi o MIBI-TEC. Os ensaios de validação do método foram realizados utilizando-se um analisador de carbono modelo TOC-Vwp acoplado a um amostrador automático modelo ASI-V, ambos da marca Shimadzu&reg e controlados por software TOC Control-V Shimadzu&reg. Foi utilizado o método direto de quantificação do CONP. Os parâmetros avaliados na validação do método foram: conformidade do sistema, robustez, linearidade, limites de detecção (LD) e de quantificação (LQ), precisão (repetibilidade e precisão intermediária), e exatidão (recuperação) e foram definidos como: 4% acidificante, 2,5 mL de oxidante, tempo de integração da curva de 4,5 minutos, tempo de sparge de 3,0 minutos e linearidade na faixa de 40-1000 μgL-1, com coeficiente de correlação (r) e soma residual dos mínimos quadrados (r2) > 0,99 respectivamente. LD e LQ para CONP foram 14,25 ppb e 47,52 ppb, respectivamente, repetibilidade entre 0,11 4,47%; a precisão intermediária entre 0,59 a 3,80% e exatidão entre 97,05 - 102,90%. A curva analítica para Mibi mostrou-se linear na faixa de 100-800 μgL-1, com r e r2 > 0,99, apresentando parâmetros similares aos das curvas analíticas de CONP. Os resultados obtidos neste estudo demonstraram que a abordagem do pior caso para validação de limpeza é um meio simples e eficaz para diminuir a complexidade e morosidade do processo de validação, além de proporcionar uma redução nos custos envolvidos nestas atividades. Todos os resultados obtidos nos ensaios de validação de método CONP atenderam as exigências e especificações preconizadas pela norma RE 899/2003 da ANVISA para considerar a metodologia validada. / Radiopharmaceuticals are defined as pharmaceutical preparations containing a radionuclide in their composition, mostly intravenously administered, and therefore compliance with the principles of Good Manufacturing Practices (GMP) is essential and indispensable. Cleaning validation is a requirement of the current GMP, and consists of documented evidence, which demonstrates that the cleaning procedures are able to remove residues to pre-determined acceptance levels, ensuring that no cross contamination occurs. A simplification of cleaning processes validation is accepted, and consists in choosing a product, called \"worst case\", to represent the cleaning processes of all equipment of the same production area. One of the steps of cleaning validation is the establishment and validation of the analytical method to quantify the residue. The aim of this study was to establish the worst case for cleaning validation of equipment in the radiopharmaceutical production of lyophilized reagent (LR) for labeling with 99mTc, evaluate the use of Total Organic Carbon (TOC) content as indicator of equipment cleaning used in the LR manufacture, validate the method of Non-Purgeable Organic Carbon (NPOC), and perform recovery tests with the product chosen as worst case.Worst case products choice was based on the calculation of an index called \"Worst Case Index\" (WCI), using information about drug solubility, difficulty of cleaning the equipment and occupancy rate of the products in line production. The products indicated as worst case was the LR MIBI-TEC. The method validation assays were performed using carbon analyser model TOC-Vwp coupled to an autosampler model ASI-V, both from Shimadzu&reg, controlled by TOC Control-V software. It was used the direct method for NPOC quantification. The parameters evaluated in the validation method were: system suitability, robustness, linearity, detection limit (DL) and quantification limit (QL), precision (repeatability and intermediate precision), and accuracy (recovery) and they were defined as follows: 4% acidifying reagent, 2.5 ml oxidizing reagent, 4.5 minutes integration curve time, 3 minutes sparge time and linearity in 40-1000 μgL-1 range, with correlation coefficient (r) and residual sum of minimum squares (r2) greater than 0.99 respectively. DL and QL for NPOC were 14.25 ppb e 47.52 ppb respectively, repeatability between 0.11 and 4.47%; the intermediate precision between 0.59 and 3.80% and accuracy between 97.05 and 102.90%. The analytical curve for Mibi was linear in 100-800 μgL-1 range with r and r2 greater than 0.99, presenting similar parameters to NPOC analytical curves. The results obtained in this study demonstrated that the worst-case approach to cleaning validation is a simple and effective way to reduce the complexity and slowness of the validation process, and provide a costs reduction involved in these activities. All results obtained in NPOC method validation assays met the requirements and specifications recommended by the RE 899/2003 Resolution from ANVISA to consider the method validated.
194

Tracer development and PET studies : labeled proinsulin C-peptide and an EGFR-TK inhibitor /

Fredriksson, Anna, January 2002 (has links)
Diss. (sammanfattning) Stockholm : Karolinska institutet, 2002. / Härtill 6 uppsatser.
195

Estudos de tecnicas de concentracao da atividade de sup(99m)Tc eluido de geradores de sup(99)Mo/sup(99m)Tc tipo gel / Studies of techniques for the post-elution concentration of 99mTc obtained from gel type 99Mo/99mTc generators

SUZUKI, KATIA N. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:27:01Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T13:56:47Z (GMT). No. of bitstreams: 0 / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP / FAPESP:06/54851-8
196

Análise da distribuição das doses ocupacionais em operações de manutenção e intervenção em áreas restritas do Centro de Radiofarmácia do IPEN / Ocupational doses distribuition analysis in operation of maintenance and interventions in restricted areas at Radiofarmacy Center of IPEN

MACHADO, JESSICA S. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:35:52Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:03:34Z (GMT). No. of bitstreams: 0 / Dissertação (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
197

Proposição de modelos cinéticos e alométricos para a dosimetria de radiofármacos marcados com lantanídeos / Kinectic and allometric models for dosimetry using radiopharmaceuticals labeled with lanthanides

LIMA, MARINA F. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:35:41Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:03:56Z (GMT). No. of bitstreams: 0 / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
198

Gestao estrategica do conhecimento. Uma metodologia de estruturacao e analise dos recursos de conhecimento / Strategic knowledge management a methodology for structuring and analyzing knowledge resources

RICCIARDI, RITA I. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:26:36Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:06:29Z (GMT). No. of bitstreams: 0 / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
199

Determinação multielementar de elementos traços em radiofármacos produzidos na Diretoria de Radiofarmácia por espectrometria de emissão por plasma / Multielemental determination of trace elements in radiopharmaceuticals produced at the Radiopharmacy Center using ICP-OES technique

TAVARES, ANGELICA T. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:41:48Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:07:05Z (GMT). No. of bitstreams: 0 / Dissertação (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
200

Desenvolvimento de um modelo de cela para processamento de radiofarmacos injetaveis / Development of a pattern hot cell for production of injectable radiopharmaceuticals

CAMPOS, FABIO E. de 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:27:28Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:06:48Z (GMT). No. of bitstreams: 0 / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP

Page generated in 0.0857 seconds