• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 51
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 52
  • 52
  • 20
  • 20
  • 18
  • 17
  • 13
  • 10
  • 9
  • 7
  • 7
  • 7
  • 7
  • 6
  • 6
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Influencia do comprimento, da ferulização e do tipo de conexão de implantes na distribuição de tensões em proteses parciais posteriores : analise fotoelastica / Length of implant, type of connection and splinttation, influence in the tensions distribution in posterior partial prosthesis : photoelastic analysis

Bastos, Poliana Lima 22 February 2008 (has links)
Orientador: Mauro Antonio de Arruda Nobilo / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-11T01:24:14Z (GMT). No. of bitstreams: 1 Bastos_PolianaLima_D.pdf: 35105529 bytes, checksum: 5a579d817d8d7350c0d5cc0ae57db9f0 (MD5) Previous issue date: 2008 / Resumo: A partir de moldes de silicone foram confeccionados oito modelos em resina fotoelástica (Araldite, Huntsman, São Paulo, Brasil), distribuídos um para cada grupo composto da seguinte forma: (G1) três coroas ferulizadas sobre implantes hexágono externo de 5,0 Ø x 7mm (Titamax Ti, Neodent, Curitiba, Brasil); (G2) três coroas unitárias sobre implantes hexágono externo de 5,0 Ø x 7mm (Titamax Ti, Neodent); (G3) três coroas ferulizadas sobre implantes hexágono externo de 5,0 Ø x13mm (Titamax Ti, Neodent); (G4) três coroas unitárias sobre implantes hexágono externo de 5,0 Ø x 13mm (Titamax Ti, Neodent); (G5) três coroas ferulizadas sobre implantes tipo Cone Morse de 5,0 Ø x 7mm (Titamax CM, Neodent); (G6) três coroas unitárias sobre implantes tipo Cone Morse de 5,0 Ø x 7mm (Titamax CM, Neodent); (G7) três coroas ferulizadas sobre implantes tipo Cone Morse de 5,0 Ø x 13mm (Titamax CM, Neodent) e (G8) três coroas unitárias sobre implantes tipo Cone Morse de 5,0 Ø x 13mm (Titamax CM, Neodent). Todas as estruturas metálicas foram inicialmente analisadas em microscopia óptica quanto à adaptação marginal, e apresentaram resultados inferiores à 40µm. Em seguida, foram avaliadas por meio de análise fotoelástica, e observou-se que todas as estruturas apresentavam padrões semelhantes de passividade. Um carregamento oclusal de 100N foi aplicado em três pontos individualmente: A (região oclusal do primeiro pré-molar), B (região oclusal do segundo pré-molar) e C (região oclusal do primeiro molar), correspondendo à saída dos parafusos. Através da técnica de fotoelasticidade avaliou-se a influência do comprimento, da ferulização e do tipo da conexão de implantes na distribuição de tensões em reabilitações posteriores de mandíbula. Os resultados encontrados pela análise da quantidade e localização de franjas fotoelásticas mostraram que o comprimento do implante parece não influenciar na distribuição de tensões, enquanto a ferulização e a conexão Cone Morse influenciaram de forma positiva na distribuição de tensões em reabilitações posteriores de mandíbula. Palavras-chave: comprimento do implante, tipo de conexão , ferulização / Abstract: Eight models were made from silicone molds in photoelastic resin (Araldite, Huntsman, Sao Paulo, Brazil), distributed one to each group composed as: (G1) three splintted crowns over external hexagon implants of 5,0 Ø x 7mm (Titamax Ti, Neodent, Curitiba, Brazil); (G2) three-unit crowns over external hexagon implant of 5.0 Ø x 7mm (Titamax Ti, Neodent); (G3) three splintted crowns over external hexagon implants of 5.0 Ø x13mm (Titamax Ti, Neodent); (G4) three-unit crowns over external implants of 5.0 Ø x 13mm (Titamax Ti, Neodent); (G5) three splintted crowns over Cone Morse implants of 5.0 Ø x 7mm (Titamax CM, Neodent); (G6) three-unit crowns over Cone Morse implants of 5.0 Ø x 7mm (Titamax CM, Neodent); (G7) three splintted crowns over Cone Morse implants of 5.0 Ø x 13mm (Titamax CM, Neodent) and (G8) three--unit crowns over Cone Morse implants of 5.0 Ø x 13mm (Titamax CM, Neodent). The edge adaptation, in all of the metallic structures, was inicially analised in optical microscopy and showed results under 40µm. After, they were analysed through photoelastic analysis and it was possible to observe that all of the structures showed similar patterns of passivity. An occlusal loading of 100N was aplied in three points individually: A (occlusal region of the first pre molar), B (occlusal region of the second pre molar) and C (occlusal region of the first molar), corresponding to the exit of the screws. Through the photoelastic technique it was possible to evaluate the influence of the length, of the splinttation and of the kind of connection of implants in the tensions distribution in posterior rehabilitations of mandible. The results found through the analysis of quantity and location of photoelastic fringes showed that the length of the implant seems not to influence in the tensions distribution, while splintation and the Cone Morse connection influenced in a positive way the tensions distribution in posterior rehabilitation of mandible. Key words: length of implant, type of connection, splinttation / Doutorado / Protese Dental / Doutor em Clínica Odontológica
12

O uso de agentes desinfetantes em materiais de moldagem: sua influência na estabilidade dimensional linear

Sávio Marcelo Leite Moreira da Silva 19 February 2003 (has links)
O objetivo deste trabalho foi avaliar a estabilidade dimensional das siliconas de condensação pesada e leve para moldagem odontológica, quando imersas em solução desinfetante por 10 e 20 minutos, relacionando a importância da biossegurança no manuseio destes materiais. Os materiais de moldagem testados foram: Optosil Confort e Xantopren VL Plus; e as soluções desinfetantes foram o hipoclorito de sódio a 1% (Solução de Milton) e o glutaraldeído a 2% (Glutaron II). Impressões foram obtidas através de moldeiras perfuradas de aço inoxidável, de acordo com a especificação n.º 19 da ADA, perfazendo um total de 50 moldagens, que foram executadas pela técnica em passo único, de acordo com as especificações do fabricante. Para assegurar a completa polimerização o material foi removido após 7 minutos e submetido à imersão nas soluções desinfetantes nos tempos determinados, sendo um grupo controle representado por moldes sem imersão. Depois de removidos das soluções, os corpos de prova foram lavados em água corrente por 15 segundos, secos e medidos 3 vezes cada para registro da média, usando um microscópio óptico, com precisão de 0,001 mm. A análise de variância a dois critérios, com nível de significância de 5%, mostrou que as diferenças nas dimensões lineares da silicona testada não são estatisticamente significantes (p>0,05) após sua imersão em solução de hipoclorito de sódio a 1% e glutaraldeído a 2% até 20 minutos. Os resultados indicaram que a combinação testada de material de moldagem e solução desinfetante pode seguramente ser empregada na clínica odontológica para o controle de infecção e segurança da equipe de saúde bucal. / The purpose of this study was to evaluate the dimensional stability of condensation silicone rubber heavy and light body after immersion in disinfectant solution for 10 or 20 minutes. The impression materials were Optosil Confort e Xantopren VL Plus and the disinfectants solutions were 1% sodium hypochlorite and 2% glutaraldehyde. Impressions were made on a perforated stainless steel tray, according to the American Dental Association specification No. 19, performed a total of 50 samples. The double mixing method (one time, two viscosities) was used. Impressions were removed from the roulette block after 7 minutes to ensure complete polymerization and then immersed in the solutions. Impressions with no treatment composed the control group. After these steps, impressions were taken out the solution and rinsed in running water and air dried. Three dimensional measurements were calculated, using an optic microscope graduated at 0,001 mm. The two- way ANOVA indicated no differences (p>0.05) for any combination between variables. The results have shown that the solution studied can be safety used to disinfect condensation silicon in clinical prosthodontic procedures.
13

Avaliação da resistência à fratura de dentes tratados endodonticamente restaurados com pinos dentários e com pinos de fibras de polietileno / Evaluation of Fracture Resistance of Endodontically Treated Teeth Reconstructed with Dentinal Post and Cores and Polyethylene Woven Fiber Ribbon Post and Cores

Osvaldo Bazzan Kaizer 05 May 2003 (has links)
Avaliou-se a resistência à fratura de dentes tratados endodonticamente reconstruídos com pinos de fibras de polietileno e com pinos dentários. Para tal, selecionaram-se 60 caninos superiores humanos seccionados na junção cementoesmalte, tratados endodonticamente (condutos desobturados até a profundidade de 8mm) e fixados em blocos de resina acrílica. Distribuíram-se os corpos de prova aleatoriamente em quatro grupos de 15 unidades: 1) preparo convencional dos condutos e confecção de pinos de fibras de polietileno; 2) preparo convencional dos condutos e pinos dentários; 3) condutos medianamente alargados e pinos dentários; 4) condutos amplamente alargados e pinos dentários. Nos grupos 1 e 2, dilataram-se os condutos até a broca Largo de número 4; nos grupos 3 e 4, os condutos sofreram desgastes seqüenciais padronizados, simulando raízes medianamente ou amplamente destruídas. No grupo 4, a espessura das paredes do conduto no terço cervical era de 0,5mm. Realizou-se a cimentação dos pinos com sistema adesivo Scotchbond Multi-Uso Plus e cimento resinoso Enforce. Construiu-se a porção coronária dos núcleos com resina composta autopolimerizável reforçada com titânio Ti-Core. Armazenaram-se os espécimes por 24 horas em água destilada, submetendo-os então aos testes de resistência à fratura sob compressão na máquina de ensaios universal Kratos, até falha do sistema. A força de compressão foi de 100 kgf e a velocidade de 0,5mm/min, sendo aplicada em ângulo de 135° em relação ao longo eixo da raiz. Os valores de resistência à fratura encontrados foram, em ordem decrescente: Grupo 3 - 58,67kgf; Grupo 2 - 3,30kgf; Grupo 4 - 47,91kgf; Grupo 1 - 45,46kgf, sendo que a análise estatística (ANOVA e Tukey) demonstrou diferença estatisticamente significante somente entre os grupos 1 e 3. Em relação ao padrão de fratura, observou-se: Grupo 1 – ampla predominância de fratura da porção coronária do núcleo; Grupo 2 e Grupo 3 – padrão variado de fraturas (tanto radiculares como do pino e/ou porção coronária); Grupo 4 – todas as raízes fraturaram. / Fracture resistance of endodontically treated teeth reconstructed with polyethylene woven fiber ribbon post and cores and dentinal post and cores has been evaluated. For that purpose, 60 human maxillary canines were selected, cut on the cementoenamel junction, endodontically treated (non- filled canal to a depth of 8mm)and fixed in acrylic resin blocks. The specimens were randomly distributed in 4 groups of 15 units each: 1) conventional canal preparation and making of polyethylene woven fiber ribbon post and cores; 2) conventional preparation of canals and dentinal post and cores; 3) fairly flared canals and dentinal post and cores; 4) greatly flared canals and dentinal post and cores. On groups 1 and 2, canals were enlarged as much as number 4 Largo bur; on groups 3 and 4, canals were subjected to standardized sequential cutting to permit a simulation of fairly or greatly flared roots. On group 4, the width of canal walls on the gingival third was 0.5mm. Post cementation was performed with the use of Scotchbond Multi-Purpose Plus bonding agent and Enforce resin cement. The core was built with self-curing composite reinforced with Ti-Core titanium. Specimens were stored in distilled water for 24 hours and subsequently subjected to compression fracture resistance tests on the Kratos universal testing machine until system failure. Load of 100kgf was applied at a speed of 0.5mm/min at an 135° angle in relation to the long axis of the root. Fracture resistance under compression presented the following values (in decreasing order): 1) group 3 – 58.67kgf; 2) group 2 – 53.30kgf; 3) group 4 – 47.91kgf; 4) group 1 – 45.46kgf. Results were subjected to statistical analysis (ANOVA and Tukey),which only showed significant statistical difference between groups 1 and 3. As to the patterns of failure, the figures observed were: group 1 - 86.6% on the post and/or core; group 2 - 46.6% on the gingival third of the root and an equal figure for post and/or core; group 3 - 40% on the gingival third of the root and 53.3% on the post and/or core; group 4 - 66% on the gingival third of the root and 33.3% on the middle third of the root.
14

"Análise da microdureza superficial Knoop e da resistência ao desgaste de dentes artificiais de resina acrílica"

Kátia Rodrigues Reis 15 June 2005 (has links)
Avaliou-se a dureza superficial Knoop de três marcas comerciais de dentes artificiais de resina acrílica convencional (Trubyte Biotone, Vipi Dent Plus e Ivostar) e quatro marcas de resina acrílica melhorada (Biotone IPN, Trilux, Biolux e Vivodent). Os espécimes (n=10) foram seccionados, planificados e mensurados em três níveis de profundidade antes e após a realização do desafio ácido. Para a avaliação da associação entre a dureza e o índice de desgaste, foram selecionadas três marcas comerciais com diferentes características: Biotone (resina acrílica convencional), Trilux (resina IPN) e Vivodent (resina com dupla ligação cruzada). A máquina de desgaste gerou a atrição dos espécimes (n=10) contra a porcelana glazeada e jateada durante 100.000 ciclos à velocidade de 4,5 ciclos por minuto sob lubrificação à água. Os valores de desgaste foram determinados em milímetros utilizando-se o microscópio comparador. Os resultados de dureza e desgaste médios foram submetidos à análise de variância a três critérios (ANOVA) e teste de Tukey para comparações múltiplas. Os valores de dureza Knoop (KHN) variaram de 17,89 a 18,62 (antes) até 16,75 a 17,72 (após) nos dentes de resina acrílica convencional e entre 17,61 a 19,64 (antes) até 17,13 a 18,8 (após) nos de resina acrílica melhorada. O desafio ácido reduziu de maneira significativa a dureza superficial dos dentes artificiais (p < 0,05). A dureza da superfície externa foi estatisticamente superior à interna em todas as marcas testadas, com exceção da marca Trilux (p < 0,05). A diferença estatística dos resultados de dureza entre as diferentes marcas comerciais foi considerada provavelmente irrelevante do ponto de vista clínico (p < 0,05). O desgaste no substrato glazeado foi de 0,14 mm (Trilux), 0,16 mm (Vivodent) e 0,17 mm (Biotone) e no substrato jateado de 0,64 mm (Vivodent), 0,66 mm (Trilux) e de 0,93 mm (Biotone). O teste Turkey revelou que os valores de desgaste da marca comercial Biotone foram estatisticamente superiores aos valores das outras marcas no substrato jateado (p < 0,05). Não houve diferença estatisticamente significante no desgaste entre as marcas de resina acrílica melhorada testadas. (p < 0,05). Não houve associação entre a dureza superficial e a resistência ao desgaste das marcas avaliadas no substrato jateado. / Knoop hardness of three conventional acrylic teeth denture brands (Trubyte Biotone, Vipi Dent Plus and Ivostar) and four improved acrylic teeth denture brands (Biotone IPN, Trilux, Biolux and Vivodent) was evaluated. The specimens (n=10) were cut, flattened and measured in three different levels into the teeth before and after being submitted to acid challenge. The correlation between hardness and wear rate was obtained through three different teeth denture brands: Biotone (conventional acrylic resin), Trilux (IPN acrylic resin) e Vivodent (acrylic resin with double cross-linked). The wear apparatus was designed to produce sliding contact of all the specimens (n=10) against glazed and sandblasting porcelain during 100.000 times at 4,5 cycles per minute, with a 4 mm sliding distance per stroke in the buccolingual direction under a 300g load of circulated water. Wear values were determined in millimeters using measuring microscope. Hardness and wear mean values were analyzed by three-way ANOVA and Tukey test. Knoop hardness data (KHN) ranged from 17,89 to 18,62 (before) and 16,75 to 17,72 (after) for conventional acrylic teeth denture and from 17,61 to 19,64 (before) and 17,13 to 18,8 (after) for improved acrylic teeth denture. The acid challenge significantly decreased the hardness to both acrylic teeth denture brands (p < 0,05). The outer surface was significantly harder than the internal one for all brands tested, exception for Trilux brand (p < 0,05). There was not uniformity in hardness between all the brands at different surfaces and ambient, preventing the election of the hardest (p < 0,05). The wear on glazed porcelain was 0,14 mm for Trilux, 0,16 mm for Vivodent and 0,17 mm for Biotone. On sandblasting porcelain, the wear was 0,64 mm for Vivodent, 0,66 mm for Trilux and 0,93 mm for Biotone. Wear rates for Biotone brand were significantly higher than the others at sandblasting porcelain (p < 0,05). The significant difference on hardness results between all brands tested was considered probably clinically insignificant (p < 0,05). There was not correlation between hardness and wear for all brands tested on sandblasting porcelain.
15

Avaliação do arco gotico de Gysi e da atividade eletromiografica computadorizada bilateral dos musculos masseter e temporal anterior, em pacientes portadores de proteses totais superiores

Lisboa, Jose Augusto Ataide 18 June 2003 (has links)
Orientador: Frederico Andrade e Silva / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-03T17:10:46Z (GMT). No. of bitstreams: 1 Lisboa_JoseAugustoAtaide_D.pdf: 6829620 bytes, checksum: 7203c2b2fda77f4b780bcc0df088535b (MD5) Previous issue date: 2003 / Resumo: Muitas vezes, pacientes reabilitados com próteses totais acabam desenvolvendo alterações funcionais do sistema estomatognático, muito embora possam parecer assintomáticos. Neles, podem ser detectadas alterações nas atividades dos músculos relacionados com a mastigação e, como conseqüência, também alterações na cinética dos côndilos durante os movimentos mandibulares. Essas alterações podem ser perpetuadas e/ou agravadas, se uma correta conduta clínica não for efetivamente realizada para normalizar a atividade funcional dos músculos, previamente à reabilitação. O tratamento com aparelhos oclusais planos previamente à reabilitação protética, foi instituído para harmonizar a atividade muscular e a cinética condilar. O arco gótico de Gysi foi obtido antes e após o tratamento com aparelhos oclusais planos e a reabilitação protética de cada um dos pacientes. Em seguida, os pacientes foram submetidos a uma avaliação eletromiográfica computadorizada dos músculos temporal anterior e masseter. A avaliação do arco gótico de Gysi mostrou que, após o tratamento, ocorreu um aumento na amplitude do mesmo, tanto durante os movimentos lateroprotrusivo como protrusivo, assim como, uma redução no desvio da linha média. A análise eletromiográfica mostrou não haver diferença estatisticamente significante para o músculo temporal anterior e masseter / Abstract: The oral rehabilitation needs a great sum of knowledge for the obtain of the functional and aesthetic success, which is the purpose of ali the efforts, during the clinical procedures. A lot of times, patients rehabilitated with total prostheses end up developing functional alterations of the stomathognatic system, althought they show no signs, their alterations can be detected in the activities of the muscles related with the mastication, and as consequence, also alterations in the kinetics of the condile during the mandibular movements . These alterations can be perpetuated and/or worsened, if a correct clinical conduct is not accomplished to normalize the functional activity of the muscles previously to the rehabilitation. The treatment with oclusal plane splints previously the prosthetic rehabilitation was instituted to harmonize the muscular activity and the kinetic condylar. The gothic arch tracing was obtained before and after the treatment with splints and prosthetic rehabilitation of each one of the patients. Soon afterwords, the patients were submitted to computerized electromyographic evaluation of the anterior temporalls and masseter muscles. The evaluation of the gothic arch tracing showed that after the treatment happened an increase in the amplitude of the same amount during the movements lateroprotrusive and protrusive, as well as a reduction in the deflection of medium line. The electromyographic analysis showed there were no significant difference between anterior temporalls and masseter muscle / Doutorado / Protese Dental / Doutor em Clínica Odontológica
16

"Análise da microdureza superficial Knoop e da resistência ao desgaste de dentes artificiais de resina acrílica"

Reis, Kátia Rodrigues 15 June 2005 (has links)
Avaliou-se a dureza superficial Knoop de três marcas comerciais de dentes artificiais de resina acrílica convencional (Trubyte Biotone, Vipi Dent Plus e Ivostar) e quatro marcas de resina acrílica melhorada (Biotone IPN, Trilux, Biolux e Vivodent). Os espécimes (n=10) foram seccionados, planificados e mensurados em três níveis de profundidade antes e após a realização do desafio ácido. Para a avaliação da associação entre a dureza e o índice de desgaste, foram selecionadas três marcas comerciais com diferentes características: Biotone (resina acrílica convencional), Trilux (resina IPN) e Vivodent (resina com dupla ligação cruzada). A máquina de desgaste gerou a atrição dos espécimes (n=10) contra a porcelana glazeada e jateada durante 100.000 ciclos à velocidade de 4,5 ciclos por minuto sob lubrificação à água. Os valores de desgaste foram determinados em milímetros utilizando-se o microscópio comparador. Os resultados de dureza e desgaste médios foram submetidos à análise de variância a três critérios (ANOVA) e teste de Tukey para comparações múltiplas. Os valores de dureza Knoop (KHN) variaram de 17,89 a 18,62 (antes) até 16,75 a 17,72 (após) nos dentes de resina acrílica convencional e entre 17,61 a 19,64 (antes) até 17,13 a 18,8 (após) nos de resina acrílica melhorada. O desafio ácido reduziu de maneira significativa a dureza superficial dos dentes artificiais (p < 0,05). A dureza da superfície externa foi estatisticamente superior à interna em todas as marcas testadas, com exceção da marca Trilux (p < 0,05). A diferença estatística dos resultados de dureza entre as diferentes marcas comerciais foi considerada provavelmente irrelevante do ponto de vista clínico (p < 0,05). O desgaste no substrato glazeado foi de 0,14 mm (Trilux), 0,16 mm (Vivodent) e 0,17 mm (Biotone) e no substrato jateado de 0,64 mm (Vivodent), 0,66 mm (Trilux) e de 0,93 mm (Biotone). O teste Turkey revelou que os valores de desgaste da marca comercial Biotone foram estatisticamente superiores aos valores das outras marcas no substrato jateado (p < 0,05). Não houve diferença estatisticamente significante no desgaste entre as marcas de resina acrílica melhorada testadas. (p < 0,05). Não houve associação entre a dureza superficial e a resistência ao desgaste das marcas avaliadas no substrato jateado. / Knoop hardness of three conventional acrylic teeth denture brands (Trubyte Biotone, Vipi Dent Plus and Ivostar) and four improved acrylic teeth denture brands (Biotone IPN, Trilux, Biolux and Vivodent) was evaluated. The specimens (n=10) were cut, flattened and measured in three different levels into the teeth before and after being submitted to acid challenge. The correlation between hardness and wear rate was obtained through three different teeth denture brands: Biotone (conventional acrylic resin), Trilux (IPN acrylic resin) e Vivodent (acrylic resin with double cross-linked). The wear apparatus was designed to produce sliding contact of all the specimens (n=10) against glazed and sandblasting porcelain during 100.000 times at 4,5 cycles per minute, with a 4 mm sliding distance per stroke in the buccolingual direction under a 300g load of circulated water. Wear values were determined in millimeters using measuring microscope. Hardness and wear mean values were analyzed by three-way ANOVA and Tukey test. Knoop hardness data (KHN) ranged from 17,89 to 18,62 (before) and 16,75 to 17,72 (after) for conventional acrylic teeth denture and from 17,61 to 19,64 (before) and 17,13 to 18,8 (after) for improved acrylic teeth denture. The acid challenge significantly decreased the hardness to both acrylic teeth denture brands (p < 0,05). The outer surface was significantly harder than the internal one for all brands tested, exception for Trilux brand (p < 0,05). There was not uniformity in hardness between all the brands at different surfaces and ambient, preventing the election of the hardest (p < 0,05). The wear on glazed porcelain was 0,14 mm for Trilux, 0,16 mm for Vivodent and 0,17 mm for Biotone. On sandblasting porcelain, the wear was 0,64 mm for Vivodent, 0,66 mm for Trilux and 0,93 mm for Biotone. Wear rates for Biotone brand were significantly higher than the others at sandblasting porcelain (p < 0,05). The significant difference on hardness results between all brands tested was considered probably clinically insignificant (p < 0,05). There was not correlation between hardness and wear for all brands tested on sandblasting porcelain.
17

Avaliação da confiabilidade e modo de falha de coroas cerâmicas parafusadas a implantes osseointegráveis de diferentes conexões /

Delben, Juliana Aparecida. January 2012 (has links)
Orientador: Wirley Gonçalves Assunção / Banca: Paulo Henrique dos Santos / Banca: Ricardo Faria Ribeiro / Banca: Nelson Renato França Alves da Silva / Banca: João Neudenir Arioli Filho / Resumo: Introdução: A performance de restaurações cerâmicas parafusadas a implantes com diferentes conexões diante de fadiga é um fator importante para o sucesso do tratamento. Proposição: O objetivo do estudo foi avaliar a confiabilidade e o modo de falha de coroas cerâmicas obtidas com pilares de zircônia parafusadas a implantes osseointegráveis de diferentes conexões. Material e método: Foram formados 3 grupos de acordo com as diferentes conexões pilar-implante: Grupo EH - hexágono externo, Grupo IH - hexágono interno e Grupo MT - Cone Morse. As coroas foram obtidas através da aplicação de cerâmica de revestimento sobre pilar de zircônia utilizando a técnica de aplicação em camadas e parafusadas aos implantes com parafusos de retenção específicos para cada sistema. Os espécimes foram submetidos ao teste de fadiga acelerado step-stress de acordo com os perfis leve (n=9), moderado (n=6) e agressivo (n=3) determinados após teste de resistência à fratura (n=4) em máquina de ensaio universal. Os dados foram inicialmente avaliados pela análise de use level probability Weibull. Os valores e intervalos de confiabilidade foram obtidos através de standard probability calculation. Considerando os valores de carga para a falha dos espécimes, foi calculada a distribuição de Weibull. Análise fractográfica foi conduzida através de estereomicroscopia e microscopia eletrônica de varredura. Resultado: O valor de β de todos os grupos (EH-β= 0,6307; IH-β=0,9730; MT-β=0,1942) sugere que as falhas foram mais associadas ao nível de carga do que ao dano acumulado. Os valores de confiabilidade para uma missão de 50.000 ciclos e carga de 400 N foram de 97% para o grupo EH, 46% para o grupo IH e 0,5% para o grupo MT com... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Introduction: The performance of screw-retained all-ceramic crowns attached to implants with different connections under fatigue is a relevant factor for treatment success. Purpose: The aim of this study was to evaluate the reliability and failure mode of screw-retained all-ceramic crowns fabricated with zirconia abutments attached to osseointegrated implants with different connections. Material and method: Three groups were designed according to the implant-abutment connection: Group EH - external hexagon, Group IH - internal hexagon and Group MT - Morse taper. Layering technique was used for veneering of zirconia abutments. The crowns were attached to the implants with the retention screws of each system. Step-stress accelerated fatigue test was conducted according to mild (n=9), moderate (n=6) and aggressive (n=3) profiles determined after single-load-to-fracture test (n=4) in a universal testing machine. Data was previously analyzed by use level probability Weibull. Standard probability calculation was used to determine the reliability and confidence bounds. Weibull distribution was calculated based on the load to failure. Failure modes were described under light polarized microscopy and scanning electron microscopy. Result: β of all groups (EH-β= 0.6307; IH-β=0.9730; MT-β=0.1942) suggested that failure was associated to load instead of cumulative damage. Significant difference was observed between the groups for the calculated reliability in a mission of 50,000 cycles at 400 N (97% for group EH, 46% for group IH... (Complete abstract click electronic access below) / Doutor
18

Avaliação da resistência à fratura de dentes tratados endodonticamente com pinos pré-fabricados e resinas compostas variando a quantidade de remanescente dentário coronal / Fracture strength assessment of teeth endodontically treated, restored with prefabricated posts and compound resins, and varying amount of remaining coronal dental structure

Melo, Murilo Pereira de 17 February 2003 (has links)
O objetivo desta pesquisa foi avaliar a influência do remanescente dentário coronal de dentes tratados endodonticamente, restaurados com pinos pré-fabricados e duas resinas como núcleos de preenchimento, uma de presa dual (Enforce Core) e outra fotopolimerizável (Z-250). Foram utilizados 40 caninos superiores humanos extraídos, divididos em quatro grupos de 10 espécimes: Grupo l – com remanescente dentário coronal de 3mm e restaurados com Enforce Core; Grupo ll – com remanescente dentário coronal de 3mm e restaurado com Z-250; Grupo III – sem remanescente dentário coronal e restaurado com Enforce Core; Grupo IV – sem remanescente dentário coronal e restaurado com Z-250. Após restaurados, os dentes foram levados a uma Máquina de Ensaio Universal e submetidos a uma força de compressão à 45º até que ocorresse fratura da restauração. A análise dos resultados (ANOVA, p>0,05) mostrou não haver diferença estatisticamente significativa entre os dentes com e sem remanescente dentário coronal. Com relação ao material utilizado para o preenchimento coronário, constatou-se diferença significativa, sendo que os valores mais elevados de resistência à fratura foram encontrados no grupo restaurado com a resina fotopolimerizável. / The aim of this study was to evaluate the remaining coronal dental structure influence of endodontically treated teeth, restored with prefabricated posts and two different types of resin filling cores, a dual cure resin (Enforce Core) and a photopolymerizing resin (Z-250). 40 extracted upper canine human teeth were used, divided into four groups of 10 specimens each: Group I – with coronal dental structure of 3mm restored with Enforce Core; Group II – with coronal dental structure of 3mm restored with Z-250; Group III – without any remaining coronal dental structure restored with Enforce Core; Group IV – without any remaining coronal dental structure restored with Z-250. After the complete restoration, the teeth were taken to a universal test machine, and then submitted to compression forces at 45º, until reaching the fracture of the restoration. The analysis of the results (ANOVA, p>0,05) showed no statistically significant difference between the teeth with or without coronal dental structure. In relation to the material used for the coronal filling, there has been a statistically significant difference. Higher fracture strength values were found in the group restored with photopolymerizing resin.
19

Influência da espessura da infraestrutura em Zircônia (3Y-TZP)na resistência mecânica da porcelana de cobertura

Lungareze, Daniel [UNESP] 27 November 2015 (has links) (PDF)
Made available in DSpace on 2015-09-17T15:26:57Z (GMT). No. of bitstreams: 0 Previous issue date: 2015-11-27. Added 1 bitstream(s) on 2015-09-17T15:44:57Z : No. of bitstreams: 1 000846104.pdf: 7431599 bytes, checksum: 6fed3b4be132c550ab3f35385ba80e2e (MD5) / Considerando o efeito das propriedades térmicas da zircônia (3Y-TZP) em infraestruturas anatômicas com maior volume, sobre a taxa de resfriamento da porcelana de cobertura e possível interferência sobre suas propriedades mecânicas, este estudo avaliou a influência da espessura da zircônia na resistência à fratura em coroas, dureza e tenacidade à fratura da porcelana e na resistência adesiva. Para o teste de resistência, foram obtidas infraestruturas em 3Y-TZP de coroas de 1º molar superior com três diferentes espessuras na oclusal: Grupo I - 1 mm, Grupo II - 2 mm e Grupo III - 3 mm. A porcelana VITA VM9 foi aplicada com espessura de 1,1 ± 0,1 mm pela técnica manual. A carga axial foi aplicada na cúspide mésiolingual por máquina de ensaios mecânicos (N=45). Para o teste de resistência de cisalhamento, foi aplicada a porcelana na forma cilíndrica com 1,2 mm de altura X 4 mm de diâmetro sobre placas de 3Y-TZP (5 x 5 mm) nas três espessuras (N= 30). O modo de falha foi analisado por microscopia óptica. Para medida da dureza Vickers e tenacidade à fratura da porcelana na interface com a 3Y-TZP e na superfície, foram usadas placas planas como descrito acima, e a porcelana aplicada, na extensão de uma das faces, com a espessura uniforme de 1,2 mm (N=24). Resultados: As médias e desvio padrão da resistência à fratura por compressão das coroas (N) foi: GI=1979 (523,5), GII=2266 (816,9) e GIII=2316 (672,9). A resistência ao cisalhamento (MPa) foi: GI=18,5 (2,44), GII=15,6 (3,80) e GIII=17,1 (3,17). A tenacidade à fratura (MPa.m1/2) foi: GI=1,53 e 1,48; GII=1,89 e 1,70 - GIII=1,84 e 1,72, respectivamente na interface e na superfície. ANOVA a um fator para resistência das coroas e ao cisalhamento, assim como a dois fatores para dureza e tenacidade a fratura não foram significantes. Concluiu-se que volumes...(Resumo completo clicar acesso eletrônico) / Considering the possible effect of the cooling delaying of zirconia (3Y-TZP) in anatomical framework for higher volume, this study evaluated the influence of the framework thickness in the fracture load of porcelain veneered crowns, bond strength between zirconia and porcelain, hardness and fracture toughness of porcelain. For testing fracture load, maxillary first molar were prepared to accomplish three different thicknesses on the occlusal surfaces: Group I - 1 mm, Group II - 2 mm and Group III - 3 mm. The thickness of 1.1 ± 0.1 mm of porcelain VITA VM9 was applied by handmade technical stratification. The axial load was applied to the medial lingual cusp by means of a mechanical test machine (N = 45). The shear test was carried-out in flat plates (5 x 5 mm) in the three thicknesses of zirconia, and the porcelain was applied as cylindrical shape with 1,2 mm high for 4 mm in diameter (N=30). The shear bond strength test was performed by chisel. For measurement of the Vickers hardness and fracture toughness flat plates were fabricated as described above, and the porcelain was applied with uniform thickness of 1.2 mm (N=24). The measurements were done close to the surface and at the interface with zirconia. The mean and standard deviation for the test were: fracture load of the crowns (N) - GI = 1979 (523,5), GII = 2266 (816.9) and GIII = 2316 (672.9); sheer bond strength (MPa) - GI=18.5 (2.44), GII=15.6 (3.80) e GIII=17.1 (3.17); fracture toughness (MPa.m1/2) - GI = 1.53 and 1.48; GII = 1.89 and 1.70 - GIII = 1.84 and 1.72, respectively at the interface and close to the surface. Data from all trials analyzed by ANOVA were not significant for all the tests, revealing that the zirconia thicknesses did not affect the porcelain resistance of the crowns, hardness and fracture toughness and adhesion between the ceramic. Conclusion: The use...(Complete abstrat electronic access below)
20

Análise de propriedades mecânicas e microscópicas de um gesso tipo IV após incorporação de derivados da clorexidina

Lucas, Matheus Guilherme [UNESP] 22 July 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:03Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-07-22Bitstream added on 2014-06-13T19:44:50Z : No. of bitstreams: 1 lucas_mg_dr_arafo.pdf: 7609787 bytes, checksum: 818d8660089a22ed3354bf205e9bb72b (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Neste trabalho foram analisadas as alterações nas propriedades físicas e mecânicas de um gesso odontológico do tipo IV após a incorporação de dois agentes desinfetantes (Digluconato e Cloridrato de clorexidina). Foram realizados testes mecânicos para a análise do tempo de presa, reprodução de detalhes, expansão de presa e resistência à compressão, já as alterações físicas foram analisadas através de uma microscopia eletrônica de varredura (MEV) nos aumentos de 375, 750, 1500 e 3000x. Os resultados demonstraram que somente houve alterações significantes no tempo de presa com a incorporação de Digluconato de Clorexidina 2,0% sem diluição e a resistência a compressão que demonstrou valores significantemente inferiores em todas as incorporações, porém todas as alterações dentro do limite estabelecido pela normatização para gessos odontológicos. Pela análise da Microscopia Eletrônica de Varredura, pode-se observar que os cristais obtiveram um aumento pela associação com os agentes derivados da clorexidina diminuindo os microporos existentes. Com isso verificamos que os derivados da clorexidina podem ser uma alternativa para a obtenção de modelos biologicamente seguros. / The purpose of this study was to evaluate the alterations in physical and mechanical properties of a gypsum tipe IV after the incorporation of two disinfectant agents (Chlorhexidine hydrochlooride and Chlorhexidine gluconate). The mechanical tests are made for setting time, reproduction details, setting expansion and compressive tensile, and the physical properties was examinated in a scanning electron microscope (SEM) and photomicrographed are made in 375, 750,1500, 3000x and compared vissually. The results demonstrated were only significant alterations in the setting time with the incorporation of Chlorhexidine gluconate without dilution and the compression resistance that demonstrated under values in all of the incorporations, however all the alterations meet inside of the established limit for I.S.O values. In the analysis of the physical properties, the crystals obtained an increase for the association with the derived agent´s clorhexidine. In conclusion, the incorporation clorhexidine agents can be a alternative to obtained biological models in dentistry.

Page generated in 0.0898 seconds