• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 21
  • 9
  • Tagged with
  • 30
  • 30
  • 26
  • 15
  • 9
  • 9
  • 6
  • 6
  • 5
  • 5
  • 5
  • 5
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Estudo prospectivo randomizado comparando duas técnicas de expansão volêmica em cirurgia de artroplastia total de quadril: hidroxietilamido (130/0,4) e Ringer lactato / Comparison between two techniques of volemic expansion during surgery to total hip arthroplasty: hydroxyethyl starch (130/0,4) and lactateds Ringer solutions. Study prospective, randomized

Adilson Hamaji 15 June 2009 (has links)
Introdução: Os hidroxietilamidos (HES) são considerados expansores plasmáticos efetivos em pacientes submetidos a procedimentos cirúrgicos de grande porte. Entretanto, seu uso clínico é limitado principalmente por sua interferência na hemostasia, representada por alterações da função plaquetária e na coagulação. A extensão dessas alterações está relacionada ao seu ipeso molecular ou à sua substituição molar. Este estudo clínico, foi realizado durante cirurgia de artroplastia de quadril em pacientes adultos para comparar os efeitos do HES (130/0,4) e a solução de Ringer lactato em relação ao sangramento intra-operatório, parâmetros hemodinâmicos, alterações na coagulação, necessidade de transfusões e resultados clínicos. Métodos: Quarenta e oito pacientes candidatos à cirurgia de artroplastia total de quadril sob anestesia subaracnoidea foram distribuídos aleatoriamente em dois grupos 24 pacientes foram selecionados para receber HES (30 ml/kg após anestesia) e 24 pacientes para receber solução de Ringer lactato (30ml/kg). O período de observação teve início após a indução da anestesia e terminou 5 horas após o termino do procedimento cirúrgico. Durante esse período o critério para a infusão de doses adicionais de fluido (10ml/kg de Solução de Ringer lactato para ambos os grupos) foi pressão arterial sistólica inferior a 90 mmHg e/ou um decréscimo de 20% da pressão arterial inicial, frequência cardíaca acima de 100 bpm, e/ou débito urinário menor de 0,4ml/kg/h. Vasopressor foi utilizado nos casos em que a hipotensão persistiu, após a reposição de volume. Transfusão de concentrado de hemácias foi administrada nos pacientes que se mantiveram instáveis hemodinamicamente após bolus adicionais de Ringer lactato ou vasopressor, Parâmetros hemodinâmicos foram mensurados em três períodos da cirurgia; dados bioquímicos foram coletados e testes da coagulação realizados e comparados. Os pacientes foram acompanhados durante sua internação hospitalar. Resultados: Os grupos foram uniformes em relação aos dados demográficos, tipo e duração da cirurgia, assim como a doenças pré-existentes. Não foram observadas diferenças significativas em relação aos parâmetros hemodinâmicos ou temperatura corporal durante o estudo. Os testes de coagulação, função plaquetária, análise de gases sanguíneos e dados bioquímicos mostraramse semelhantes entre os grupos. Perdas sanguíneas foram significativamente maiores no grupo HES (1296x890,p=0,04), necessitou de menos unidades de concentrado de hemácias durante o período observacional (17%versus46%, p=0,029) apresentou menores taxas de infecção (0 versus 4 ,p<0,03), comparado ao grupo Ringer lactato. Conclusões: Em cirurgia de artroplastia total de quadrill, a hemodiluição com hidroxietilamido resultou em maiores taxas de sangramento, menos transfusões sanguíneas e menos infecção pós-operatória. / Introduction: Hydroxyethyl starches (HES) are considered effective plasma expanders in patients undergoing major surgeries. However, the clinical use of HES is limited mainly by their affection of hemostasis, detectable by impaired platelet function and altered coagulation. The extent of such alteration has classically been related to the molecular weight or molar substitution of the used HES solution. This prospective, randomized study was performed during hip arthroplasty in adult patients under spinal anesthesia to compare the effects of HES 130/0.4 with lactateds Ringer solution regarding intraoperative bleeding, hemodynamic parameters, coagulation profile, transfusion requirements and clinical outcomes. Methods: Forty eight patients scheduled to hip arthroplasty after spinal anesthesia were randomized in two groups 24 patients were allocated to receive HES 130/0.4 (30 ml/Kg just after anesthesia) and 24 patients were signaled to receive lactateds Ringer solution (30 ml/Kg). The observational period started after the induction of anesthesia and finished 5 hours after the end of the surgery. During this period, the triggers for infusion of additional boluses of fluids (10 ml/Kg of lactateds Ringer for both groups) were a systolic blood pressure lower than 90 mmHg and/or a decrease of 20% from baseline, a heart rate higher than 100 bpm, and/or a urine output lower than 0.4 ml.Kg-1.h-1. Vasopressors were used if there was persistent hypotension despite of fluid reposition. Red blood cell transfusion was administered if patient remained unstable despite of additional boluses of Ringer or vasopressors, according to the preestablished triggers. Hemodynamic measurements were done in three periods of the surgery, biochemical parameters were analyzed and coagulation tests were performed and compared between groups. After surgery, patients were followed during the hospital stay. Results: The groups were well matched regarding demographic data, type of surgery, and duration of surgery, as well as preexisting diseases. No significant differences in hemodynamic or body temperature were seen during the study. Coagulation variables, platelet function, gases analysis and biochemical parameters were not different between groups. Blood losses were significantly higher in HES 130/0.4 group comparing to Ringers group (1296 x 890 ml, p= 0.046). Despite of that, HES group required less units of blood in the observational period comparing to Ringer group (17% versus 46%, p=0.029). HES group presented lower infection rate compared to Ringer group (0 versus 4 cases, p=0.03). Conclusions: During hip arthroplasty, hemodilution with hydroxyethyl starch 130/0.4 resulted in higher rates of bleeding. However, patients treated with hydroxyethyl starch required less transfusion and presented lower rate of infection.
22

Estudo comparativo entre a via de acesso minimamente invasiva posterior e a via de acesso lateral direta nas artroplastias totais do quadril não cimentadas / Prospective comparative study of the minimally invasive posterior approach and the direct lateral approach to total hip uncemented arthroplasty

José Ricardo Negreiros Vicente 21 November 2007 (has links)
Um estudo terapêutico comparativo prospectivo é realizado para avaliar o acesso posterior minimamente invasivo em artroplastia total do quadril comparado com o acesso lateral direto tradicional. O estudo inclui 76 pacientes submetidos à artroplastia total do quadril primárias não cimentadas por diagnóstico de osteoartrose primária e secundária. Não são incluídos, pacientes com qualquer tipo de coagulopatia, em uso de anticoagulantes ou antiagregante plaquetário, pacientes hipertensos sem controle medicamentoso, pacientes submetidos à qualquer cirurgia prévia do quadril, e pacientes com seqüela de displasia do desenvolvimento do quadril que tenham a cabeça femoral ectópica. O objetivo principal deste estudo é avaliar a perda volêmica que ocorre nestes pacientes. Há diferença de média de idade (p=0,017) no acesso minimamente invasivo (50,1 anos) em relação ao grupo controle (56,8 anos), porém não observamos diferenças entre os grupos quanto ao índice de massa corpórea, lado operado e diagnóstico inicial. Observa-se um sangramento menor (p<0,001) no período intra-operatório (745,6 ml contra 1282,8 ml), assim como, menor sangramento total (p<0,001) no acesso minimamente invasivo posterior (1083,5 ml contra 1682,3 ml). Relatamos diferença entre os grupos quanto à necessidade de transfusão alogênica, favorável aos pacientes do grupo minimamente invasivo (p=0,02), com 8,8% dos pacientes sendo transfundidos em relação a 28,6% dos pacientes do grupo controle. Nossa estimativa de sangramento no acesso minimamente invasivo posterior é significativamente maior que a literatura, porém a quantidade de unidades de concentrados de hemáceas transfundidas,assim como, a proporção de pacientes transfundidos são menores em relação aos outros autores. Concluímos que os pacientes submetidos ao acesso minimamente invasivo posterior apresentam menor sangramento, melhor resultado clínico precoce e posicionamento adequado dos componentes da prótese. / A therapeutic, comparative, prospective study was carried out to evaluate the minimally invasive posterior approach to total hip arthroplasty in relation to the traditional direct lateral approach. The study included 76 cases of primary total hip arthroplasty due to a diagnosis of primary or secondary osteoarthrosis. Patients were excluded from the study if they presented any type of coagulopathy and were using anticoagulants or platelet antiagregants; hypertension without medicinal control; any previous hip surgery; and sequelae of hip developmental dysplasia that might have led to an ectopic femoral head. The objective of our study was to evaluate the blood loss among patients for whom the minimally invasive posterior access is used. Regarding our patients\' ages, we observed a significant difference between the two groups: the mean age of the mini-incision group (50,1 years) was lower than the mean of the control group (56,8 years), p= 0.01. Lower total estimated bleeding was found in the mini-incision group (means of 1083,5 ml versus 1682,3 ml; p < 0.001) and lower intraoperative bleeding (means of 745,6 ml versus 1282,8 ml; p <0.001). There was difference in the need of allogenic transfusion between the two groups (8,8% versus 28,6%,p = 0.13). Our volumes of bleeding from the minimally invasive posterior approach were significantly higher than in the literature, but the mean quantity of transfused red cells and the proportion of transfused patients were both significantly lower than in the literature. Our final impression of the minimally invasive approach is positive with regard to lower blood loss, better clinical results after six months and a satisfactory alignment of the acetabular and femoral components.
23

Contrôle postural et patron locomoteur à la suite d'une arthroplastie de la hanche : effet du type de prothèse

Nantel, Julie January 2008 (has links)
Thèse numérisée par la Division de la gestion de documents et des archives de l'Université de Montréal.
24

Cultura dos tecidos profundos na artroplastia total primária do quadril: valor prognóstico para infecção periprotética / Multiple deep tissue cultures in primary total hip arthroplasty: prognostic value for periprosthetic infection

Ferro, Fernando Portilho 27 March 2019 (has links)
INTRODUÇÃO: A artroplastia total do quadril é um dos procedimentos mais frequentes na ortopedia. O risco de infecção varia de 1 a 5%, e acarreta grande impacto negativo na qualidade de vida do paciente, além de envolver custos expressivos. O diagnóstico e tratamento precoce da infecção permite um tratamento mais rápido e efetivo, o que pode melhorar o resultado clínico final. Sabe-se que germes patogênicos podem contaminar o campo cirúrgico durante a cirurgia, apesar de rigorosa técnica asséptica, mas existe debate na literatura sobre a existência de benefício em identificar tais germes já na artroplastia primária em pacientes não infectados. Embora a coleta de múltiplas amostras para cultura seja prática bem estabelecida em procedimentos de revisão, permanece controversa a coleta de culturas em artroplastias primárias. Diversas bactérias podem contaminar o campo operatório durante a cirurgia, mas somente seriam capazes de causar infecção aquelas que contaminarem os planos anatômicos mais profundos. O objetivo deste estudo foi investigar se há valor prognóstico na realização de cultura de amostras profundas de tecido ósseo e de partes moles durante a realização da artroplastia total primária do quadril, buscando correlação entre a positividade das culturas e de infecção periprotética subsequente. MÉTODOS: Estudo retrospectivo, utilizando informações obtidas do prontuário médico e do sistema informatizado de consulta de exames laboratoriais. Foram colhidas amostras profundas (osso femoral, acetabular e cápsula) de 426 casos consecutivos de artroplastia total primária eletiva do quadril. Os pacientes foram seguidos por no mínimo três anos e foram identificados os pacientes que evoluíram com infecção. O perfil microbiológico das culturas nas cirurgias primárias foi comparado com aquele dos pacientes infectados. Adicionalmente, os prontuários foram revisados para a identificação de fatores de risco associados a maior risco de infecção periprotética. RESULTADOS: 54 cirurgias (12,6%) apresentaram culturas positivas. 16 casos (3,8%) evoluíram com infecção, dos quais cinco haviam apresentado cultura positiva na cirurgia primária. Os germes isolados nos pacientes infectados não coincidiram com os identificados na cirurgia índice. A taxa de infecção foi de 9,3% nos pacientes com cultura positiva e 3% naqueles com cultura negativa (p < 0,05), com um \"odds ratio\" de 3,34 (IC95% 1,09-10,24). Pacientes submetidos a alguma cirurgia prévia no quadril apresentaram taxa de infecção de 8,5%, sendo que tal percentual foi de 2,9% nos pacientes sem cirurgia prévia (p < 0,05). O único fator de risco associado a uma maior positividade de culturas foi o tabagismo (10,5% vs 23,6%, p < 0,05). CONCLUSÃO: Dentre os pacientes submetidos à artroplastia total primária do quadril, aqueles com cultura positiva apresentaram maior risco de desenvolvimento de infecção periprotética (IPP). Pacientes submetidos a algum procedimento cirúrgico prévio no mesmo quadril apresentaram maior risco de IPP / INTRODUCTION: The total hip arthroplasty is one of the most frequent procedures in orthopedics. The risk of infection usually varies from 1% to 5% and has a great negative impact on patients\' quality of life, while also involving significant costs. The diagnosis and early treatment of infection allows a faster and more effective treatment, which can improve the final clinical result. It is known that pathogenic germs can contaminate the surgical theater, despite strict aseptic technique, but there is debate in the literature regarding the benefit of identifying such germs during the primary arthroplasty in non-infected patients. Although the obtainment of multiple samples for culture is a well-established practice in revision procedures, the obtainment of cultures in primary arthroplasties remains controversial. Several bacteria can contaminate the operative field during surgery, but only those that contaminate the deeper anatomical layers should be capable of causing infection. The aim of this study was to investigate if there is prognostic value in the culture of deep samples of bone and soft tissues during primary total hip arthroplasty, seeking a correlation between the positivity of the cultures and subsequent periprosthetic infection. METHODS: This was a retrospective study, using information obtained from medical records and a computerized system for consultation of laboratory tests. Deep samples (femoral bone, acetabular bone and capsule) were collected from 426 consecutive cases of elective primary total hip arthroplasty. Patients were followed up for at least three years and patients who had developed infection were identified. The microbiological profile of cultures in the primary surgeries was compared to that of the infected patients. In addition, the medical records were reviewed for the identification of risk factors associated with a higher risk of periprosthetic infection. RESULTS: 54 surgeries (12.6%) presented positive cultures. 16 cases (3.8%) developed infection, of which five had presented a positive culture in the primary surgery. Isolated germs in infected patients did not coincide with those identified in the index surgery. The infection rate was 9.3% in patients with positive culture and 3% in those with negative culture (p < 0.05), with an odds ratio of 3.34 (95% CI 1.09-10.24). Patients who had a previous hip surgery had an infection rate of 8.5%, and this percentage was 2.9% in patients with no previous surgery (p < 0.05). The only risk factor associated with a higher risk of culture positivity was smoking (10.5% vs. 23.6%, p < 0.05). CONCLUSION: Among patients undergoing primary total hip arthroplasty, those with a positive culture had a higher risk of developing periprosthetic infection (PPI). Patients who had undergone previous surgical procedures in the same hip also presented a higher risk of PPI
25

Biomateriais com aplicabilidade na ortopedia: avanços e desafios na área da infectologia / Biomaterials with applicability in orthopedics: advances and challenges in the infectology area

Marques, Daniella Maia 05 July 2018 (has links)
O controle na formação do biofilme em implantes e próteses ortopédicas continua sendo um dos grandes desafios acerca da infeção relacionada aos dispositivos na área da saúde. O objetivo desta pesquisa foi investigar biomateriais com aplicabilidade na ortopedia, visando os avanços e enfrentamentos dos desafios na área da infectologia. Uma revisão integrativa foi realizada a respeito da formação de biofilme em biomateriais de próteses de quadril com a finalidade de contribuir com as medidas de prevenção e controle aos agravos infecciosos. Além disso, a formação in vitro do biofilme em função dos biomateriais (titânio e titânio revestido com biovidro F18), microrganismos (Staphylococcus epidermidis e Candida albicans) e tempos de incubação (2, 4 e 8 horas) foi avaliada por microscopia de fluorescência. A revisão integrativa foi realizada no portal PubMed da National Library of Medicine, bem como nas bases Cochrane, Embase, Web of Science, CINAHL e LILACS com a inclusão de estudos primários sobre a temática, publicados online até novembro de 2017, em português, inglês e espanhol. Na fase experimental / laboratorial, biofilmes de S. epidermidis (ATCC 12228) e C. albicans (ATCC 90028) foram formados em corpos de prova de titânio e titânio revestido com biovidro F18 após 2, 4 e 8 horas de incubação a 37?C sob agitação orbital. As áreas das imagens dos corpos de prova, em porcentagem, recobertas com biofilme (células vivas) foram avaliadas por microscopia de fluorescência. Os dados coletados foram submetidos à análise estatística empregando-se os testes de normalidade Shapiro Wilk, U de Mann-Whitney e t de Student por meio do software IBM SPSS Statistics (versão 25) e nível de significância ?=5%. Na revisão integrativa, os resultados demonstraram que dos 16 estudos primários, 81,25% eram pesquisas experimentais in vitro e que novos biomateriais foram desenvolvidos para prevenir a formação de biofilme. Com relação à fase experimental / laboratorial, houve menor formação de biofilme por S. epidermidis e C. albicans (p<0,001) no titânio revestido com biovidro F18 do que no titânio, após 8 horas de incubação. Entretanto, houve maior formação de biofilme por S. epidermidis e C. albicans após 8 horas do que em 2 horas de incubação, tanto no titânio quanto no titânio revestido com biovidro F18 (p<0,05). Em suma, a revista da literatura mencionou o desenvolvimento de biomateriais novos para prevenir a formação de biofilme. Na fase laboratorial / experimental, o titânio revestido com biovidro F18 apresentou atividade antibiofilme em comparação com o titânio, e os tempos de incubação de 2 para 8 horas aumentaram a formação de biofilme em ambos os biomateriais. Ainda, pesquisas futuras acerca do biovidro F18 fundamentadas nos aspectos físicoquímicos, bioquímicos e microbiológicos são importantes para a elucidação dos mecanismos de ação relacionados ao controle dos biofilmes / The control of biofilm formation on implants and orthopedic prostheses still is one of the major challenges concerning infection related to devices in the health field. The objective of this research was to investigate biomaterials with applicability in orthopedics, aiming for advances and facing challenges in the infectology area. An integrative review was performed regarding biofilm formation on hip prosthesis biomaterials in order to contribute to the preventive and infection control measures. Moreover, the in vitro biofilm formation according to biomaterials (titanium and titanium coated with F18 bioglass), microorganisms (Staphylococcus epidermidis and Candida albicans) and incubation times (2, 4 and 8 hours) was evaluated by fluorescence microscopy. The integrative review was performed on PubMed portal from National Library of Medicine as well as on Cochrane, Embase, Web of Science, CINAHL and LILACS databases with the inclusion of primary studies about the topic, published online up until November 2017, in Portuguese, English and Spanish. In the experimental / laboratory step, S. epidermidis (ATCC 12228) and C. albicans (ATCC 90028) biofilms were formed on proof bodies of titanium and titanium coated with F18 bioglass after 2, 4 and 8 hours of incubation at 37?C under orbital shaking. The image areas of proof bodies, in percentage, coated with biofilm (living cells) were evaluated by fluorescence microscopy. The data collected were submitted to statistical analysis using normality tests Shapiro Wilk, U from Mann-Whitney and t from Student through IBM SPSS Statistics (version 25) software and significance level ?=5%. In the integrative review, the results showed that among 16 primary studies, 81.25% were in vitro experimental studies and that new biomaterials were developed to prevent biofilm formation. Regarding experimental / laboratory step, there was less biofilm formation by S. epidermidis and C. albicans (p<0.001) on titanium coated with F18 bioglass than on titanium, after 8 hours of incubation. However, there was more biofilm formation by S. epidermidis and C. albicans after 8 hours than in 2 hours of incubation, both on titanium and on titanium coated with F18 bioglass (p<0.05). In sum, the literature review mentioned the development of new biomaterials to prevent biofilm formation. In laboratory / experimental step, titanium coated with F18 bioglass presented antibiofilm activity in comparison with titanium, and the incubation times of 2 to 8 hours increased biofilm formation on both materials. Besides, future studies about F18 bioglass based on physicochemical, biochemical and microbiological aspects are important for the elucidation of action mechanisms related to biofilms control
26

Contrôle postural et patron locomoteur à la suite d'une arthroplastie de la hanche : effet du type de prothèse

Nantel, Julie January 2008 (has links)
Thèse numérisée par la Division de la gestion de documents et des archives de l'Université de Montréal
27

Coagulase-negative staphylococci in prosthetic hip infections /

Nilsdotter, Åsa, January 2005 (has links) (PDF)
Diss. (sammanfattning) Linköping : Linköpings universitet, 2005. / Härtill 5 uppsatser.
28

Eficácia do uso do Templating na artroplastia total do quadril.

Devito, Fábio Stucchi 17 April 2009 (has links)
Made available in DSpace on 2016-01-26T12:51:22Z (GMT). No. of bitstreams: 1 fabiostuchidevito_tese.pdf: 1050230 bytes, checksum: 52d8e95acef4a4ba2f5e60d301266786 (MD5) Previous issue date: 2009-04-17 / Total hip arthroplasty is a surgery with a high success rate, providing pain relief and improvement of the articular mobility. Long-term success is related to the position and orientation of the acetabular and femoral components. Traditional preoperative planning entails radiographic analysis of the pelvis, in which a template is placed on the image, allowing an analysis of the appropriate size of the Exeter cemented prosthesis. Objective: To evaluate the effectiveness of traditional preoperative planning with the use of templating. Patients and Method: Forty-three anteroposterior X-rays were analyzed by three experienced surgeons. The evaluation of each surgeon was compared with the actual prosthesis used in the surgery and also compared with the assessment of the other two surgeons. Cohen's Kappa concordance test and weighted Kappa indexes using quadratic weighting were used for statistical analysis with a confidence interval of 95%. Results: The preoperative evaluations of Surgeons A, B and C were divided into the analysis of the sizes of the acetabular cup, stem and plug of the distal femoral canal. Surgeon A obtained a moderate agreement in relation to the acetabular component and substantial agreements in relation to the stem and plug. Surgeon B had moderate agreement in relation to both the acetabulum and the stem and substantial agreement in relation to the plug. Surgeon C obtained moderate agreement in relation to the analysis of the acetabulum and the plug and substantial agreement for the stem. The intra-observer agreement test demonstrated a prevalence of slight agreement in relation to the acetabulum and substantial agreement in relation to the stem and to the plug. Conclusion: Templating used in preoperative planning proved effective; however, there was a prevalence of slight and moderate agreement in relation to the size of the acetabular component according to the inter- and intra-observer analysis. / A artroplastia total do quadril é uma cirurgia com alto índice de sucesso, atuando no alívio da dor e melhora da mobilidade articular e seu êxito a longo prazo relaciona-se à posição e orientação do componente acetabular e femoral. O planejamento pré-operatório tradicional consiste na análise radiográfica da bacia, na qual será sobreposto um templating , o que permite a análise do tamanho adequado da prótese Exeter cimentada. Objetivo: Avaliar a eficácia do planejamento pré-operatório tradicional pelo uso do templating . Casuística e Método: Quarenta e três radiografias na posição antero-posterior e foram analisadas por três cirurgiões experientes; as avaliações de cada cirurgião foram comparadas com a prótese utilizada na cirurgia e cada resultado comparado com os resultados dos outros dois. Para avaliação, utilizou-se o teste de concordância do Capa de Cohen e do Capa ponderado, com ponderação quadrática e intervalo de confiança de 95%.Resultados: Os resultados pré-operatório encontrados pelo examinadores A, B e C foram divididos como análise do tamanho do acetábulo, haste e plug do canal femoral distal. O cirurgião A obteve em relação ao componente acetabular uma concordância moderada, e em relação à haste e ao plug uma concordância substancial. O cirurgião B apresentou resultado de concordância moderada em relação ao acetábulo e à haste e substancial em relação ao plug. O cirurgião C na análise acetabular e do plug obteve concordância moderada e substancial quanto à haste. O teste de concordância intra-observador apresentou uma prevalência da concordância leve em relação ao acetábulo e substancial em relação à haste e ao plug. Conclusão: O templating utilizado no planejamento pré-operatório mostrou-se eficaz, no entanto, em relação ao tamanho do componente acetabular houve um predomínio de concordância leve e moderada na análise inter e intraobservador.
29

"Estudo comparativo do tratamento das artroplastias infectadas do quadril sem e com o uso do espaçador de cimento com antibiótico" / Prospective study of the treatment of chronically infected hip replacements with and without the use of an antibiotic-loaded acrylic cement spacer

Cabrita, Henrique Antonio Berwanger de Amorim 12 April 2004 (has links)
Em um estudo prospectivo sobre o tratamento das artroplastias de quadril infectadas, com perdas ósseas e fístulas ativas, 25 pacientes foram tratados em dois tempos e 36 pacientes foram tratados em dois tempos com espaçador de cimento impregnado com vancomicina. O acompanhamento médio foi de dois anos e onze meses. A taxa de recidiva infecciosa foi de 29,2% nos tratados em dois tempos e de 8,8% nos tratados com espaçador. O Escore de Harris para Quadril médio passou de 19,3 para 69,0 pontos nos casos tratados em dois tempos e de 19,7 para 72,2 pontos nos pacientes tratados com espaçador. Ao final do estudo, 86,1% dos tratados com espaçador e em 33,3% dos tratados em dois tempos tinham próteses em bom funcionamento e sem infecção. O espaçador de cimento com antibiótico é o tratamento de escolha nas próteses infectadas de quadril / We report a prospective study of 61 patients with chronically deep infected hip replacements with actively discharging sinuses, treated with a two-stage revision protocol, with and without a cement spacer impregnated with vancomycin. The average follow-up was two years and eleven months. Twenty-five patients were treated without a spacer and seven had recurrence of infection. Thirty-three patients were treated with a spacer and three had recurrence of infection. The average Harris Hip score increased from 19,3 to 69,0 on the non-spacer patients and from 19,7 to 75,2 on the spacer group. At the end of the study, the success rate was 86,1% for the spacer group and 33,3% for the non-spacer group. The use of the spacer increased the results of the two-stage chronic infected hip replacements
30

"Estudo comparativo do tratamento das artroplastias infectadas do quadril sem e com o uso do espaçador de cimento com antibiótico" / Prospective study of the treatment of chronically infected hip replacements with and without the use of an antibiotic-loaded acrylic cement spacer

Henrique Antonio Berwanger de Amorim Cabrita 12 April 2004 (has links)
Em um estudo prospectivo sobre o tratamento das artroplastias de quadril infectadas, com perdas ósseas e fístulas ativas, 25 pacientes foram tratados em dois tempos e 36 pacientes foram tratados em dois tempos com espaçador de cimento impregnado com vancomicina. O acompanhamento médio foi de dois anos e onze meses. A taxa de recidiva infecciosa foi de 29,2% nos tratados em dois tempos e de 8,8% nos tratados com espaçador. O Escore de Harris para Quadril médio passou de 19,3 para 69,0 pontos nos casos tratados em dois tempos e de 19,7 para 72,2 pontos nos pacientes tratados com espaçador. Ao final do estudo, 86,1% dos tratados com espaçador e em 33,3% dos tratados em dois tempos tinham próteses em bom funcionamento e sem infecção. O espaçador de cimento com antibiótico é o tratamento de escolha nas próteses infectadas de quadril / We report a prospective study of 61 patients with chronically deep infected hip replacements with actively discharging sinuses, treated with a two-stage revision protocol, with and without a cement spacer impregnated with vancomycin. The average follow-up was two years and eleven months. Twenty-five patients were treated without a spacer and seven had recurrence of infection. Thirty-three patients were treated with a spacer and three had recurrence of infection. The average Harris Hip score increased from 19,3 to 69,0 on the non-spacer patients and from 19,7 to 75,2 on the spacer group. At the end of the study, the success rate was 86,1% for the spacer group and 33,3% for the non-spacer group. The use of the spacer increased the results of the two-stage chronic infected hip replacements

Page generated in 0.0957 seconds