• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 62
  • 4
  • 4
  • Tagged with
  • 72
  • 72
  • 37
  • 35
  • 23
  • 21
  • 20
  • 19
  • 18
  • 17
  • 17
  • 17
  • 17
  • 13
  • 13
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

The effect of hydrofluoric acid etching on zirconia bond strength and surface properties

Al Shaltoni, Reem Mohamad Saleem 01 September 2023 (has links)
OBJECTIVES: This in-vitro study aimed to evaluate the effect of hydrofluoric acid etching and airborne particle abrasion on zirconia bond strength, using three different types of cement. To assess the impact of hydrofluoric acid etching on zirconia surface roughness and investigate the effect of hydrofluoric acid etching on zirconia's surface topography, microstructure, and crystal structure. MATERIALS AND METHODS: Crown-abutment simulation systems were constructed, using a custom-made zirconia tapered ring model and tapered titanium pin-abutments. Twelve groups were included in the study and classified according to the surface treatment and type of cement used. Each group had 10 specimens for a total of 120 test specimens. The fully sintered zirconia ring was alumina particle abrasion (APA) treated with a 50-μm alumina and/or etched with 9.5% HF acid, solution for 1 minute. The Ti pin was APA treated with 125-μm alumina. Three different types of cement were used: one RMGIC (GC FujiCem Evolve) and two resin composite types of cement (Panavia SA Universal and Panavia V5). A cementing jig was used to standardize the cementation process of the titanium pins to the zirconia rings. An Instron was used to obtain the retention load values. The failure load between the zirconia ring and the titanium pin was determined using an axial pullout test and the values were statistically analyzed for the effects of etching treatment, APA treatment, and cement type using JMP Pro 16. Zirconia-disk specimens were constructed using a custom-made disk model. Thirteen groups were included in the study and classified according to the hydrofluoric acid etching concentrations, consistencies, and timing used. Each group had 3 specimens. The total specimen size was thirty-nine specimens. Disks were polished and etched using 5% HF, 9.5% HF, and 40% HF acid etching concentrations, gel, and solution consistencies, and for 1 and 15 minutes of etching time. Disks were examined with an SEM, X-Ray diffractometer, and a profilometer for microstructure, crystallography, and surface roughness, respectively. RESULTS: HF acid-etching treatment significantly increased retention load compared to non-etched groups. There was no significant difference in retention load between APA-treated and non-APA-treated groups. Groups cemented with Panavia V5 showed a higher retention load compared to GC FujiCem Evolve and Panavia SA Universal. There was no significant difference in the surface roughness among the etched groups and the control groups. Roughening of the crystal boundaries with irregularities and pits was observed under SEM. As etching time and concentration increased the surface became rougher and more irregular. There were no obvious crystal structure differences between the etched groups and non-etched groups. CONCLUSIONS: Significantly different retention loads were found among tested groups. Hydrofluoric acid etching increases the bond strength of zirconia and titanium, using resin composite cement. Using hydrofluoric acid etching to pre-treat the zirconia surface may be an alternative approach to obtain sufficient bonding strength.
12

Estudo comparativo entre diferentes cimentos endodônticos em relação à resistência de união do conjunto cimento resinoso/pino de fibra de vidro à dentina radicular / Comparative study between different endodontic sealers in relation to the bond strength of the resin cement / fiberglass post complex to the root dentin

Soares, Isadora Mello Vilarinho 03 August 2018 (has links)
O objetivo do estudo foi avaliar, comparativamente, a influência do cimento biocerâmico EndoSequence BC a diferentes cimentos endodônticos sobre a resistência de união do conjuno cimento resinoso/pino de fibra de vidro à dentina radicular. Setenta e dois dentes caninos selecionados tiveram a coroa seccionada transversalmente e o remanescente radicular padronizado em 17mm. O canal radicular foi preparado com Reciproc R50 e NaOCl 1%. Os espécimes foram distribuídos conforme o cimento obturador utilizado (n=12): G1-controle (sem cimento); G2- óxido de zinco e eugenol (EndoFill) G3- hidróxido de cálcio (Sealapex); G4- resina epóxi (AHPlus); G5-resina epóxi e hidróxido de cálcio (Sealer Plus) e G6- biocerâmico (EndoSequence BC). Decorridas 48h da obturação, as raízes foram desobturadas e preparadas para receber o pino de fibra de vidro. Após secagem do canal, os pinos foram cimentados com Panavia F 2.0. Dez raízes de cada grupo foram seccionadas transversalmente para obtenção dos slices. O primeiro slice de cada terço foi submetido ao teste de resistência de união (push-out) e padrão de falha. No segundo slice foi avaliada a interface adesiva dentina/cimento resinoso, por meio de microscopia de varredura confocal a laser (MVCL). Dois espécimes de cada grupo não tiveram o pino cimentado no canal radicular e foram destinados à microscopia eletrônica de varredura para observação de remanescente de material obturador na superfície dentinária. Os dados referentes à resistência de união foram submetidos ao teste Shapiro-Wilk, seguido de ANOVA two way. Os dados referentes à MVCL foram analisados pelo teste Kruskal-Wallis seguido pelo teste Dunn ( = 5%). Os grupos controle e AHPLus apresentaram os maiores valores de RU (p<0,05). Os cimentos EndoSequence BC, Sealer Plus e Sealapex apresentaram os valores intermediários de RU, sem diferença estatística entre eles. O cimento EndoFill apresentou os menores valores de RU com diferença estatisticamente significante em relação aos demais grupos (p<0,05). Quanto aos terços radiculares, os maiores valores de RU foram observados no terço cervical (p<0,05). As imagens de MEV demonstraram no geral, presença de poucos remanescentes de material obturador na superfície radicular em todos os grupos. Quanto a análise da interface cimento resinoso/dentina, a maioria dos grupos apresentou adaptação razoável, com exceção do EndoFill. Concluiu-se que os cimentos endodônticos Endosequence BC, Sealapex, Sealer Plus e EndoFill influenciaram negativamente a RU do conjunto pino/cimento resinoso à dentina radicular / The aim of this study was to compare the influence of EndoSequence BC bioceramic sealer on the bond strength (BS) of resin cement/fiber post in root canals filled with different sealers. The coronary of seventy-two canines were removed and the root length standardized at 17mm. The root canal was prepared with Reciproc R50 and 1% NaOCl. The specimens were distributed according to the filling material used (n=12): G1- control (no sealer); G2- zinc oxide and eugenol (EndoFill) G3- calcium hydroxide (Sealapex); G4- epoxy resin (AHPlus); G5- epoxy resin and calcium hydroxide (Sealer Plus) and G6- bioceramic (EndoSequence BC). Later forthy eight hours, the roots were prepared to insert the fiberpost. Fiberposts were attached with Panavia F 2.0. Ten roots of each group were sectioned transversely, obtaining slices of cervical, medium and apical root canal thirds. The BS of the first slice of each third was evaluated by push-out test and failures was analyzed by stereo microscope. The interface between dentin wall/resin cement of the second slice was evaluated by confocal laser microscopy (CLM). Two specimens from group were not restored with fiberpost, and assigned to scanning electron microscopy (SEM) to analyze the remaining material on the dentin surface. Data on the bond strength were submitted to the Shapiro-Wilk test, followed by two way ANOVA. The CLM data were submitted to the Kruskal-Wallis and Dunn tests ( = 5%). The control and AHPLus groups had the highest RU values (p <0.05). The EndoSequence BC, Sealer Plus and Sealapex sealers presented the intermediate values of RU, with no statistical difference between them. EndoFill sealer presented the lowest values of RU with a statistically significant difference in relation to the other groups (p <0.05). Regarding root thirds, the highest BS values were observed in cervical third (p <0.05). SEM images showed presence of few remaning filling material on the root surface in all groups. Regarding the dentine/resin cement interfaces analyzes most of the groups presented average adaptation, unless the G2. It was concluded that Endosequence BC, Sealapex, Sealer Plus and EndoFill endodontic sealers poor influenced the BS of the fiber post/resin cement in root canal dentin
13

Influência das unidades fotoativadoras e do material restaurador indireto sobre a dureza de um cimento resinoso dual auto-adesivo e um cimento resinoso dual convencional por meio de teste de nanoendentação / Influence of curing units and restorative indirect material on hardness of a dual cure self-adhesive resin cement and dual cure conventional resin cement through nanoindentadion test

Kuguimiya, Rosiane Nogueira 05 December 2013 (has links)
O objetivo deste estudo foi avaliar a dureza de um cimento resinoso dual autoadesivo (RelyX U200) e um cimento resinoso dual convencional (RelyX ARC) fotoativados sob materiais restauradores indiretos, utilizando unidades fotoativadoras com diferentes comprimentos de ondas (LED Elipar Freelight 2, LED Bluephase, Laser AccuCure 3000TM), por meio de teste de nanoendentação. Para a obtenção dos espécimes foram utilizados incisivos bovinos que após profilaxia, foram submetidos a cortes no limite amelo-cementário para a separação da porção coronária. Após inclusão, os espécimes foram submetidos ao desgaste para exposição de dentina e padronização do substrato. Para simular clinicamente restaurações indiretas foram confeccionadas peças em cerâmica IPS e.max® Press (Ivoclar Vivadent) e em resina composta indireta SR Adoro (Ivoclar Vivadent) que foram cimentadas nas superfícies dentinárias. Os espécimes foram seccionados longitudinalmente em baixa velocidade e constante irrigação e polidos em politriz. Foi estabelecido um grupo controle positivo, no qual o cimento foi fotoativado sem a interposição de material restaurador indireto e um grupo controle negativo, no qual, após a cimentação do material restaurador indireto, a fotoativação foi suprimida, ocorrendo apenas a polimerização química do cimento. Todos os espécimes foram armazenados em água destilada a 37°C durante 7 dias e após esse período, foram submetidos ao teste de nanoendentação na linha de cimentação, com o auxílo do ultra-microdurômetro (Shimadzu Dynamic Ultra Micro Hardness Tester). O ciclo aplicado foi de 100mN. Foram realizadas cinco nanoendentações em cada espécime, cujas médias resultaram nos valores de cada superfície. Os resultados obtidos foram submetidos à Análise de Variância e Teste de Tukey (p<0,05). Podese concluir que o cimento RelyX ARC apresentou maiores valores de dureza do que o RelyX U200 e este foi mais dependente da fotoativação para alcançar uma polimerização adequada. A dureza dos cimentos resinosos avaliados foi influenciada negativamente pela interposição do material restaurador indireto e apenas os LEDs foram capazes de manter o mesmo grau de polimerização dos cimentos quando interposto um material restaurador indireto. / This study aimed to evaluate the hardness of a dual cure self-adhesive resin cement (RelyX U200) and a dual cure conventional resin cement (RelyX ARC) light curing units with different wavelengths (Elipar Freelight 2 LED, Bluephase LED, AccuCure 3000TM Laser) through nanoindentadion test. To obtain the specimens bovine incisors were used after prophylaxis. The tooth were sectioned at the limit amelocement for the separation of the coronal portion. After inclusion, the dentin surface of the specimens were exposed to standardize the substrate. To clinically simulate indirect restorations ceramic pieces were made (IPS e.max® Press/Ivoclar Vivadent) and indirect composite resin (SR Adoro/Ivoclar Vivadent) were cemented on dentin surfaces. The specimens were sectioned longitudinally at low speed with constant irrigation and polished. A positive control group was stablished, in which the cement was light cured without the interposition of indirect restorative material, and a negative control group, in which, after cementation of the indirect restorative material, the light curing was removed, occurring only the chemical polymerization of the cement. All specimens were stored in distilled water at 37°C for 7 days. Nanoindentadion hardness of the cement layer was measured under 100mN load (Shimadzu Dynamic Ultra Micro Hardness Tester). Five nanoindentations in each specimen were obtained, which resulted in the average values of each surface. Data were statistically analyzed using ANOVA and Tukey test (p<0,05). RelyX ARC pesented higher values of hardness than RelyX U200 and this was more dependent on the polymerization. The hardness of the evaluated resin cements was negatively influenced by the interposition of an indirect restorative material and only the LEDs were able to maintain the same degree of polymerization of the cement when an indirect restorative material was used.
14

Resistência adesiva dos cimentos resinosos convencionais e autoadesivos à dentina contaminada por saliva / Bond strength of different composite resin cements and dentin interfaces contaminated with saliva

Acosta Servián, Victor Manuel 20 April 2012 (has links)
Muitas das lesões dentárias necessitam de restaurações indiretas que requerem cimentos adesivos para a sua fixação à estrutura dentária. Em algumas situações não é possível realizar o isolamento absoluto do campo operatório, o que pode levar à contaminação com saliva da dentina previamente aos procedimentos adesivos. Assim é necessário saber o nível de comprometimento da adesão em função deste fato. O presente estudo teve como objetivo analisar o tratamento da dentina contaminada com saliva na resistência adesiva dos cimentos resinosos convencional e autoadesivo através de testes de cisalhamento. Foram utilizados 50 incisivos bovinos que foram lixados até a exposição de dentina superficial e divididos em 6 grupos: Grupo ARC (controle): condicionamento ácido por 15s + sistema adesivo Scotchbond Multipurpose (3M/ESPE) + cimento RelyX ARC (3M/ESPE); Grupo ARClav: condicionamento ácido por 15s + contaminação com saliva + lavagem com água/ar 20 segundos + sistema adesivo + cimento RelyX ARC; Grupo ARCsec: condicionamento ácido por 15s + contaminação com saliva + secagem com papel absorvente + cimento autoadesivo RelyX ARC; Grupo ARCre: condicionamento ácido por 15s, contaminação + secagem jato de ar + recondicionamento por 15s + sistema adesivo Scotchbond Multipurpose + cimento RelyX ARC; Grupo U100 (controle): sem contaminação + cimento autoadesivo RelyX U100 (3M/ESPE); Grupo U100sec: contaminação + secagem jato de ar + cimento autoadesivo RelyX U100. Após a cimentação, os dentes foram armazenados em água destilada a 37ºC por 24 horas antes da realização do teste de cisalhamento. Os resultados obtidos foram submetidos à análise de variância a dois critérios e teste de Tukey com nível de significância de 5%. As médias gerais, dos grupos,expressas em MPa, foram G ARC: 9,02 ± 1,36 - G U100: 4,38 ± 0,74 - GARClav: 6,43 ± 0,98 GARCsec: 7,71 ± 1,14 GARCre: 5,68 ± 1,10 G U100sec: 3,87 ± 0,51. A análise dos resultados permitiu concluir que a adesão do cimento RelyX à dentina contaminada com saliva, lavada ou recondicionada com ácido fosfórico diminui significantemente quando comparada à adesão à dentina não contaminada ou àquela contaminada e apenas seca com papel absorvente. Já a contaminação com saliva não afetou significantemente a adesão do cimento RelyX U100 à dentina. / Many dental injuries require indirect restorations fixed by adhesive cements. In some situations is not possible to isolate the operative field, which can lead to contamination by saliva of the dentin. The aim of this study was to analyze the treatment of dentin contaminated with saliva on shear bond strength of conventional and self-adhesive resin cements. Fifty bovine incisors were ground until exposure of dentin surface and divided into six groups: Group ARC (control) no contamination + acid etch for 15s + Scotchbond Multipurpose system (3M/ESPE) + cement Rely X ARC (3M/ESPE); Group U100 (control): no contamination + self-adhesive cement RelyX U100 (3M/ESPE), Group ARClav: acid etch for 15s + saliva contamination + rising with water / air + adhesive system RelyX ARC, Group ARCsec: acid etch + contamination with saliva + drying with absorbent paper cement RelyX ARC, Group ARCre: acid etched, contamination with saliva + drying with absorbent paper + reetched for 15s + adhesive system Scotchbond Multipurpose + cement RelyX ARC, Group U100sec: contamination + drying with absorbent paper + self-adhesive cement RelyX U100. After cementation, the teeth were stored in distilled water at 37° C for 24 hours prior to shear testing. The results were analyzed by One-way ANOVA and Tukey\'sTests with a significance level of 5% were: G ARC: 9.02 ± 1.36 G U100: 4.38 ± 0.74 G ARClav: 6.43 ± 0.98 G ARCsec: 7.71 ± 1.14 G ARCre: 5, 68 ± 1.10 G U100sec: 3.87 ± 0.51.The results showed that there was a significant difference in bond strength of RelyX ARC to dentin contaminated by saliva when it was rinsed or re-etched, but there was no difference when the contaminated dentin was just dried with absorbent paper. No statistical difference was found between the adhesion resistance of the RelyX U100 to dentin with or without saliva contamination.
15

Influência da espessura da cerâmica, do tempo de fotopolimerização e do cimento resinoso na resistência de união à microtração de uma cerâmica vítrea cimentada à dentina humana /

Barca, Diana Capelli. January 2010 (has links)
Orientador: Carlos Augusto Pavanelli / Banca: Henrique Cerveira Netto / Banca: Rodrigo Othavio de Assunção e Souza / Resumo: Este estudo avaliou a influência da espessura da cerâmica, do tempo e tipo de fotopolimerização do cimento resinoso na resistência da união entre uma cerâmica vítrea e a dentina coronária humana. A hipótese é a de que o tipo e o tempo de fotopolimerização do agente cimentante e a espessura da cerâmica influenciem na resistência de união entre cimento e dentina. Foram selecionados cento e doze dentes molares humanos hígidos que foram incluídos em resina acrílica e tiveram a superfície oclusal cortadas em máquina Labcut, expondo a dentina planificada. Dois grupos foram tiveram a dentina condicionada com ácido fosfórico 37% lavada e aplicado adesivo (Excite, Ivoclar) fotopolimerizando por 20s. No grupo controle (n=16), utilizou-se cimento auto-adesivo. Foram confeccionados cento e doze blocos (6 x 6 mm) de cerâmica feldspática (Vita PM9) com três espessuras: 1, 2 e 3 mm que tiveram a superfície de cimentação tratad a com ácido fluorídrico 10%, lavada, seca e silanizada. Os blocos cerâmicos foram cimentados, de acordo com o grupo experimental: Variolink II (Ivoclar Vivadent); e fotopolimerizados com LED por 40 ou 80 segundos de fotopolimerização ou cimento Multilink II (no grupo controle). Assim, formaram-se sete grupos (n=16). Os espécimes foram armazenados em água destilada (37°C) por 24 horas e seccionados em dois eixos, X e Y, para a obtenção dos espécimes. Cada grupo (N=16) foi subdividido em 2 (n=8) onde um grupo foi termociclado e o outro submetido ao ensaio de microtração 24 horas após a cimentação. Esse palito (cerâmica/dente) foi fixado no dispositivo de microtração Erios, levado à máquina de ensaio universal e testado com velocidade de 1 mm/min. Os valores médios obtidos (MPa) foram à análise de Variáveis ANOVA 3- fatores, teste de Dunnett e ao teste de Tukey (5%). A resistência adesiva foi significantemente influenciada pelos fatores... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: This study evaluated the influence of the thickness of the ceramic, time and type of light curing resin cement on bond strength between a ceramic and glass human dentin. The hypothesis is that the type and time of curing luting agent and the thickness of the ceramic bearing on the bond strength between cement and dentin. We selected one hundred and twelve healthy human molar teeth were embedded in acrylic resin and were cut in the occlusal surface Labcut machine, exposing the dentin. Two groups have had to dentin conditioned with 37% phosphoric acid washed applied adhesive (Excite, Ivoclar) light cured for 20s. In the control group (n = 16), we used self-adhesive cement. We made one hundred and twelve blocks (6 x 6 mm) ceramic feldspathic (Vita PM9) with three thicknesses: 1, 2 and 3 mm that had cement surface treated with hydrofluoric acid 10%, washed, dried, and silanized. The ceramic blocks were cemented according to the experimental group: Variolink II (Ivoclar Vivadent) and cured with LED for 40 or 80 seconds of curing cement Multilink or II (control group). Thus, they formed seven groups (N = 16). The specimens were stored in distilled water (37 ° C) for 24 hours and sectioned in two axes, X and Y, to obtain the specimens. Each group (N = 16) was subdivided into two (n = 8) where a group was thermocycled and another test by microtensile 24 hours after cementation. This toothpick (ceramic / tooth) was mounted in microtensile Erios, led to a universal testing machine and tested at a speed of 1 mm / min. The average values (MPa) were the ANOVA analysis of three variables - factors, Dunnett test and Tukey test (5%). The bond strength was significantly influenced by light irradiation time, thickness of the ceramic thermal cycling / Mestre
16

Avaliação da influência do tipo de cerâmica e protocolo de ativação no grau de conversão de cimentos resinosos por meio da espectroscopia Raman / Evaluation of the ceramic type and curing protocol on the degree conversion of resin cements used to lute full ceramic crowns by Raman spectroscopy

Lanza, Marcos Daniel Septimio 29 June 2012 (has links)
É crescente a aplicação dos cimentos à base de resina em próteses em cerâmica por exibirem propriedades estéticas e biomecânicas superiores aos cimentos convencionais. O presente estudo teve por objetivo avaliar o grau de conversão (GC) de quatro cimentos resinosos, sendo um com modo de polimerização físico (ChoiceTM 2/Bisco Inc), 2 com modo de polimerização dual (DuolinkTM/ Bisco Inc; VariolinkII®/Ivoclar-Vivadent) e um cimento com modo de polimerização químico (C&BTM/Bisco Inc), empregados na cimentação de coroas confeccionadas em cerâmica. Foram utilizados 42 pré-molares humanos que foram preparados para receber coroas totais confeccionadas com 2 sistemas cerâmicos: cerâmica de dissilicato de lítio (IPS e.MaxPress/Ivoclar-Vivadent®) e cerâmica de óxido de Zircônia estabilizada por Itrio (IPS e.maxZirCAD/Ivoclar-Vivadent®) para confecção dos copings, tendo uma cerâmica a base de fluorapatita como cobertura (IPS e.maxZirPresss/Ivoclar-Vivadent). Para a cimentação os dentes/coroas/cimento foram subdivididos aleatoriamente e, a foto ativação dos cimentos dual e físico, foi realizada com dois protocolos: foto-ativação nas faces vestibular, oclusal e lingual, com o tempo de exposição de 20s sequencialmente e foto-ativação somente por oclusal pelo tempo de 60s. O cimento químico foi mantido sem aturdimento por 15 minutos. Após a cimentação, os espécimes foram armazenados em água deionizada em estufa com temperatura de ±36oC e seccionados transversalmente após 7 dias em 3 regiões: cervical, no centro da coroa e 2mm aquém da face oclusal. O grau de conversão foi determinado pela técnica da espectroscopia Micro-Raman ao longo da linha de cimento nas face vestibular, mesial, lingual e distal. Os resultados foram submetidos a uma análise estatística ANOVA os quais mostraram que o GC dos cimentos com ativação em três faces sequencialmente depende da interação entre o tipo da cerâmica e da marca comercial do cimento; o GC sob a cerâmica de dissilicato de lítio é maior do que sob as cerâmicas de zircônia; em relação as faces e terços, o GC mostrou ser material dependente. Conclui-se que, o protocolo de ativação e a composição da cerâmica tem influência no GC dos cimentos analisados. / There is a growing application of resin-based cements in ceramic prostheses for displaying aesthetic and biomechanical properties superior to conventional cements. The present study aimed to evaluate the degree conversion (DC) of four resin cements, one with physical curing mode (ChoiceTM 2/Bisco Inc), two dualcuring mode (DuolinkTM / Bisco Inc; VariolinkII® / Ivoclar-Vivadent) and one chemical curing mode (C&BTM / Bisco Inc) employed in the cementation of crowns made of ceramic. We used 42 human premolars were prepared to receive full crowns made with two ceramic systems: lithium disilicate ceramic (IPS eMaxPress/Ivoclar- Vivadent®) and Yttrium oxide stabilized zirconia (IPS e.maxZirCAD / Ivoclar - Vivadent®) for the fabrication of copings, with a ceramic veneer as fluorapatite based (IPS e.maxZirPresss / Ivoclar-Vivadent). For cementation, teeth/crowns/cement were randomly divided, and the photo activation of dual cements and physical, was performed with two protocols: photo-activation in the buccal, occlusal and lingual, with an exposure time of 20s in each face and photo-activation only by occlusal for 60s. The cement chemical was maintained for 15 minutes without stunning. After cementation, specimens were stored in deionized water in an oven at a temperature of 37°C and sectioned after 7 days in three regions : cervical, in the center of the crown and 2 mm below the occlusal surface. The degree of conversion was determined along the cement line in the buccal, mesial, lingual and distal by micro- Raman spectroscopy. The results were submitted to statistic analysis by ANOVA which showed that the DC of cements with activation in three sequentially faces depends on the relationship by ceramic composition and cement trademark; the DC under lithium dissilicate ceramic is greater than in the zirconia; regarding the faces and thirds, DC proved to be material dependent. In conclusion, curing protocol and ceramic composition has a influence on DC of the cements analyzed.
17

Avaliação de tratamentos de superfície na união de cimento resinoso ao titânio comercialmente puro

Almeida Junior, Antonio Alves de [UNESP] 26 March 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:38Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-03-26Bitstream added on 2014-06-13T20:18:31Z : No. of bitstreams: 1 almeidajunior_aa_me_arafo.pdf: 459545 bytes, checksum: df0008777c6ad28ca07cacdc0ed332ac (MD5) / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / Este estudo avaliou a resistência ao cisalhamento da união entre o titânio comercialmente puro fundido e o cimento resinoso não-adesivo (RelyX ARC – 3M ESPE) após diferentes tratamentos na superfície metálica. Noventa discos de titânio comercialmente puro foram divididos aleatoriamente em nove grupos, os quais receberam um dos seguintes tratamentos, antes da aplicação do RelyX ARC: (n=10): 01) Al2O3 (50 μm); 02) Al2O3 (50 μm) + adesivo; 03) Al2O3 (50 μm) + silano; 04) Cojet Sand (30 μm); 05) Cojet Sand + adesivo; 06) Cojet Sand + silano; 07) Al2O3 (50 μm) + Rocatec (110 μm); 08) Al2O3 (50 μm) + Rocatec + adesivo; 09) Al2O3 (50 μm) + Rocatec + silano. Os espécimes foram termociclados (5.000 ciclos - 5 – 55 oC - 30 segundos de imersão) e então submetidos ao ensaio de cisalhamento As médias de resistência ao cisalhamento da união dos grupos de 1 a 9 foram respectivamente: 4,10 ± 0,79CD; 6,14 ± 0,99B; 4,34 ± 0,71CD; 2,58 ± 0,37EF; 2,31 ± 0,23 F; 5,70 ± 0,93B; 3,65 ± 0,70DE; 5,25 ± 1,08BC e 8,36 ± 1,63A. O teste t de Student apontou igualdade estatística entre os grupos jateados com partículas de Al2O3 e com partículas revestidas por sílica (P=0,630). A análise de 22 variância (ANOVA) a dois critérios seguida pelo teste de Tukey indicaram que: 1) o Rocatec apresentou resistência significativamente maior que o Cojet Sand (P<0,05); 2) o jateamento com partículas de óxido de alumínio apresentou resistência significativamente maior quando associado ao adesivo (P<0,001) enquanto o silano foi o melhor tratamento pós jateamento para as partículas revestidas por sílica (P<0,001) e 3) O jateamento com Rocatec seguido da aplicação do silano proporcionou a maior resistência ao cisalhamento de união entre o titânio comercialmente puro e o RelyX ARC. Todos os grupos apresentaram falha 100% adesiva. / This study evaluated the shear bond strength of a conventional resin cement (RelyX ARC – 3M ESPE) to cast commercially pure titanium (cp Ti) after different treatments on metal surface. Ninety cp Ti disks were randomly divided into 9 groups which received one of the following treatments before the application of RelyX ARC: (n=10): 01) Al2O3 (50 μm); 02) Al2O3 (50 μm) + adhesive; 03) Al2O3 (50 μm) + silane; 04) Cojet Sand (30 μm); 05) Cojet Sand + adhesive; 06) Cojet Sand + silane; 07) Al2O3 (50 μm) + Rocatec (110 μm); 08) Al2O3 (50 μm) + Rocatec + adhesive; 09) Al2O3 (50 μm) + Rocatec + silane. All specimens were thermal cycled (5000 cycles, 5 - 55 oC – 30-second dwell time) before tested in shear mode. The mean bond strength values (Mpa) for all groups were, respectively: 4,10 ± 0,79CD; 6,14 ± 0,99B; 4,34 ± 0,71CD; 2,58 ± 0,37EF; 2,31 ± 0,23 F; 5,70 ± 0,93B; 3,65 ± 0,70DE; 5,25 ± 1,08BC e 8,36 ± 1,63A. The Student t test showed that there was no significant difference between Al2O3 particles and silica-modified Al2O3 particles (P=0.630). Two-way ANOVA and post hoc Tukey test (=.05) showed that: 1) Rocatec demonstrated significantly higher shear bond strength than Cojet Sand (P<0.05); 2) airborne-particle abrasion with Al2O3 particles exhibited the highest shear bond strength with adhesive (P<0.001) while silica-modified Al2O3 particles exhibited the best behavior when associated with silane (P<0.001); 3) Rocatec plus silane provided the highest shear bond strength between cp Ti and RelyX ARC. All groups showed 100% adhesive failure.
18

Influência da espessura da cerâmica, do tempo de fotopolimerização e do cimento resinoso na resistência de união à microtração de uma cerâmica vítrea cimentada à dentina humana

Barca, Diana Capelli [UNESP] 07 July 2010 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:57Z (GMT). No. of bitstreams: 0 Previous issue date: 2010-07-07Bitstream added on 2014-06-13T18:35:10Z : No. of bitstreams: 1 barca_dc_me_sjc.pdf: 4808947 bytes, checksum: 238892d410325de1d23eb76694cb9763 (MD5) / Este estudo avaliou a influência da espessura da cerâmica, do tempo e tipo de fotopolimerização do cimento resinoso na resistência da união entre uma cerâmica vítrea e a dentina coronária humana. A hipótese é a de que o tipo e o tempo de fotopolimerização do agente cimentante e a espessura da cerâmica influenciem na resistência de união entre cimento e dentina. Foram selecionados cento e doze dentes molares humanos hígidos que foram incluídos em resina acrílica e tiveram a superfície oclusal cortadas em máquina Labcut, expondo a dentina planificada. Dois grupos foram tiveram a dentina condicionada com ácido fosfórico 37% lavada e aplicado adesivo (Excite, Ivoclar) fotopolimerizando por 20s. No grupo controle (n=16), utilizou-se cimento auto-adesivo. Foram confeccionados cento e doze blocos (6 x 6 mm) de cerâmica feldspática (Vita PM9) com três espessuras: 1, 2 e 3 mm que tiveram a superfície de cimentação tratad a com ácido fluorídrico 10%, lavada, seca e silanizada. Os blocos cerâmicos foram cimentados, de acordo com o grupo experimental: Variolink II (Ivoclar Vivadent); e fotopolimerizados com LED por 40 ou 80 segundos de fotopolimerização ou cimento Multilink II (no grupo controle). Assim, formaram-se sete grupos (n=16). Os espécimes foram armazenados em água destilada (37°C) por 24 horas e seccionados em dois eixos, X e Y, para a obtenção dos espécimes. Cada grupo (N=16) foi subdividido em 2 (n=8) onde um grupo foi termociclado e o outro submetido ao ensaio de microtração 24 horas após a cimentação. Esse palito (cerâmica/dente) foi fixado no dispositivo de microtração Erios, levado à máquina de ensaio universal e testado com velocidade de 1 mm/min. Os valores médios obtidos (MPa) foram à análise de Variáveis ANOVA 3- fatores, teste de Dunnett e ao teste de Tukey (5%). A resistência adesiva foi significantemente influenciada pelos fatores... / This study evaluated the influence of the thickness of the ceramic, time and type of light curing resin cement on bond strength between a ceramic and glass human dentin. The hypothesis is that the type and time of curing luting agent and the thickness of the ceramic bearing on the bond strength between cement and dentin. We selected one hundred and twelve healthy human molar teeth were embedded in acrylic resin and were cut in the occlusal surface Labcut machine, exposing the dentin. Two groups have had to dentin conditioned with 37% phosphoric acid washed applied adhesive (Excite, Ivoclar) light cured for 20s. In the control group (n = 16), we used self-adhesive cement. We made one hundred and twelve blocks (6 x 6 mm) ceramic feldspathic (Vita PM9) with three thicknesses: 1, 2 and 3 mm that had cement surface treated with hydrofluoric acid 10%, washed, dried, and silanized. The ceramic blocks were cemented according to the experimental group: Variolink II (Ivoclar Vivadent) and cured with LED for 40 or 80 seconds of curing cement Multilink or II (control group). Thus, they formed seven groups (N = 16). The specimens were stored in distilled water (37 ° C) for 24 hours and sectioned in two axes, X and Y, to obtain the specimens. Each group (N = 16) was subdivided into two (n = 8) where a group was thermocycled and another test by microtensile 24 hours after cementation. This toothpick (ceramic / tooth) was mounted in microtensile Erios, led to a universal testing machine and tested at a speed of 1 mm / min. The average values (MPa) were the ANOVA analysis of three variables - factors, Dunnett test and Tukey test (5%). The bond strength was significantly influenced by light irradiation time, thickness of the ceramic thermal cycling
19

Influência da fonte de fotoativação sobre a resistência de união entre um pino de fibra de vidro e um cimento resinoso, em diferentes profundidades.

Freitas, Gustavo Pinheiro de January 2007 (has links)
82f. / Submitted by Suelen Reis (suziy.ellen@gmail.com) on 2013-04-23T18:03:32Z No. of bitstreams: 1 Dissertacao Gustavo de Freitas.pdf: 4255443 bytes, checksum: e1c6da0abf59a84ad236924bb2db824b (MD5) / Approved for entry into archive by Rodrigo Meirelles(rodrigomei@ufba.br) on 2013-05-08T12:35:27Z (GMT) No. of bitstreams: 1 Dissertacao Gustavo de Freitas.pdf: 4255443 bytes, checksum: e1c6da0abf59a84ad236924bb2db824b (MD5) / Made available in DSpace on 2013-05-08T12:35:27Z (GMT). No. of bitstreams: 1 Dissertacao Gustavo de Freitas.pdf: 4255443 bytes, checksum: e1c6da0abf59a84ad236924bb2db824b (MD5) Previous issue date: 2007 / O objetivo deste trabalho foi avaliar a resistência de união entre um pino de fibra de vidro e um cimento resinoso. Trinta cilindros de resina composta foram confeccionados e pinos de fibra de vidro (ReforPost - Angellus) cimentados em seu interior com um cimento resinoso dual (RELY-X – 3M). A fotoativação do cimento foi feita variando-se as fontes de luz (Halógena e LED). Cada um dos 30 cilindros foi cortado em três partes (terço cervical, médio e apical), resultando 90 discos que foram divididos em 09 grupos (n=10): Grupo 1- Oc: Optlight Plus – GNATUS, terço cervical; Grupo 2-Om: Optlight Plus – GNATUS, médio; Grupo 3-Oa: Optlight Plus – GNATUS, apical; Grupo 4-RC: RADII – SDI, cervical; Grupo 5 Rm: RADII – SDI, médio; Grupo 6-RC: RADII – SDI, apical; Grupo 7- Ec: Elipar Freelight2 – 3M, cervical; Grupo 8-Em: Elipar Freelight2 – 3M, médio; Grupo 9- Ea: Elipar Freelight2 – 3M, apical. Todos os grupos foram submetidos ao ensaio de tração diametral (DTS) em uma máquina de ensaios (EMIC 2000) até a fratura. As médias dos grupos em Mpa foram: G1-Oc: 25,08 (4,20); G2-Om: 23,44 (4,64); G3-Oa: 20,88 (3,62) G4- Rc: 22,86 (5,93); G5-Rm: 22,12 (6,72); G6-Ra: 22,04 (5,61); G7-Ec: 26,01 (3,33); G8-Em: 19,81 (6,09); G9-Ea: 17,74 (4,14). A análise estatística dos dados permitiu concluir que, o grupo G 9–Ea apresentou a menor resistência à tração diametral demonstrando diferença estatisticamente significante quando comparado com os grupos G7-Ec e G1-Oc e não houve influência das diferentes fontes de luz. Com base nestes resultados também podemos afirmar que o aparelho LED (RADII – SDI) apresentou valores de DTS constantes em todos os terços analisados. / Salvador
20

Influência do modo de ativação e de uma restauração simulada de porcelana no grau de conversão e na dureza superficial de um cimento resinoso auto-adesivo de cura dual / Influence of polymerization mode and a simulated ceramic restoration on degree of conversion and surface hardness of a dual-cured self-adhesive resin cement

Irma Cunha Matos 28 February 2008 (has links)
Este estudo objetivou analisar o grau de conversão (GC) e a microdureza de um cimento resinoso utilizando diferentes protocolos de ativação, e, caracterizar o cimento quanto à composição monomérica, diâmetro médio das partículas inorgânicas e porcentagem em peso das frações orgânica e inorgânica. Foram preparados quarenta espécimes (8mm de diâmetro, 0,5mm de espessura), sendo metade usada para a determinação do GC e a outra metade usada no teste de microdureza. Os espécimes foram divididos em quatro grupos: GR1 fotoativação realizada diretamente sobre o cimento por 20s, GR2 fotoativação através de um disco de porcelana com 2mm de espessura por 20s, GR3 fotoativação através de um disco de porcelana com 2mm de espessura por 40s, e GR4 fotoativação foi omitida e o material foi polimerizado exclusivamente por seus componentes químicos. A dureza Vickers (HV) e o GC, determinado através de FTIR-ATR, foram realizados imediatamente após a fotoativação (GR1, GR2 e GR3) ou cinco minutos após o início da polimerização (GR4). Após armazenagem em ambiente seco e escuro por 24h, os espécimes foram novamente submetidos aos testes de HV e GC. Para a caracterização do material avaliado, foram realizadas as análises: Termogravimétrica, Espectrometria no Infravermelho, Espectrometria de Ressonância Magnética Nuclear e Microscopia Eletrônica de Varredura. Os resultados foram analisados estatisticamente por ANOVA, teste t e teste de Bonferroni (P&#8804;0,05). Os valores do GC nos períodos imediato e 24h foram, respectivamente: GR1: 29.64% 4.05 / 32.58% 2.99; GR2: 27.07% 2.39 / 28.9%1 3.9 / GR3: 28.18% 3.6 / 32.34% 4.04; GR4: 7.94% 2.4 / 20.38% 4.89. Os valores de HV nos períodos imediato e 24h foram, respectivamente: GR1: 7.98HV 1.8 / 14.88HV 2.33; GR2: 4.84HV 0.13 / 9.06HV 1.63; GR3: 6.53HV 2.51 / 11.42HV 1.97. A baixa polimerização para o GR4 não permitiu a determinação da dureza inicial e após 24h este valor foi 10.65HV 0.92. O modo de ativação autopolimerizável influenciou negativamente o GC e a HV em relação ao modo de ativação no qual foi utilizada a fotoativação. A restauração simulada de porcelana não influenciou o GC, porém interferiu negativamente na microdureza. O tempo de fotoativação não influenciou os valores do GC e da HV. O GC e microdureza sofreram um aumento significativo após 24h da polimerização inicial, com exceção do GC no período inicial, quando a fotoativação foi realizada através de um disco de porcelana por um tempo de exposição de 20s. Houve uma correlação linear e positiva entre a HV e o GC para o cimento RelyX&#61668; Unicem. Caracterização química: porção orgânica composta por uma mistura de monômeros, tendo o Bis-GMA como monômero-base. Presença de um monômero dimetacrilato contendo hidroxila para se ligar ao ácido fosfórico sob a forma de fosfato. Partículas inorgânicas variando entre 0,4 a 11,2&#61549;m. A fração sólida do material é composta por 96% de partículas inorgânicas. Na fração líquida, a porção orgânica corresponde a 84%. Restou um resíduo incombustível de 16% devido à queima do material em atmosfera de nitrogênio. / The aim of this study was to evaluate the degree of conversion (DC) and the microhardness of a self-adhesive resin cement under different activation protocols, immediately and after 24 hours of the beginning of the polymerization, and, defining cement regarding monomer composition, average diameter of the inorganic fillers and the percentage by weight of the organic and inorganic portions. Forty specimens (8 mm in diameter, 0.5 mm in height) were prepared. Half of them were used to determine DC and the other half were used on the microhardness test. The specimens were divided into four groups: GR1 direct photoactivation for 20s, GR2 photoactivation through 2mm porcelain disc for 20s, GR3 photoactivation through 2 mm porcelain disc for 40 s, and GR4 photoactivation was omitted and curing was reliant on the chemical reaction only. Vickers microhardness (HV) and DC, by FTIR-ATR, were determined immediately after photoactivation (GR1, GR2 e GR3) or after five minutes from the beginning of the polymerization (GR4). After dry storage in the dark, for 24 hours, the samples were submitted to the tests again. In order to define the studied cement, the Thermogravimetric method was applied, as well as the Infrared Spectometry, Nuclear Magnetic Ressonance Spectroscopy and Scanning Electron Microscope. Data were statistically analyzed by one-way ANOVA, t-Test and Bonferroni Test (P&#8804;0,05) and the degree of conversion values obtained immediately after polymerization and after 24 hours were, respectively: GR1: 29.64% 4.05 / 32.58% 2.99; GR2: 27.07% 2.39 / 28.9%1 3.9 / GR3: 28.18% 3.6 / 32.34% 4.04; GR4: 7.94% 2.4 / 20.38% 4.89. HV values obtained immediately after polymerization and after 24 hours were, respectively: GR1: 7.98HV 1.8 / 14.88HV 2.33; GR2: 4.84HV 0.13 / 9.06HV 1.63; GR3: 6.53HV 2.51 / 11.42HV 1.97. The low DC for GR4 do not permitted to quantify the initial HV value and after 24 hours this values was 10.65HV 0.92. The chemical curing mode showed DC and HV results for both period (initial and after 24 hours), statistically lower than the other groups where the photoactivation was used. The simulated ceramic restoration did not influence monomer conversion, however it negatively influence resin cement hardness. The exposure time did not influence resin cement hardness and monomer conversion. The inical DC and HV were significantly greater than after 24 hours, except for DC for initial period, when the photoactivation was realizded through a porcelain disc for 20s.There was a linear and positive correlation between degree of conversion and microhadness for the self-adhesive resin cement RelyX&#61668; Unicem. Defining the cement: organic portion composed by a mixture of monomers. Bis-GMA is the main monomer. Presence of a dimethacrylate containing hydroxyl to connect to the phosphoric acid as a phosphate. Inorganic fillers raging between 0,4 to 11,2&#61549;m. Powder is composed by 96% of inorganic particles. In liquid fraction, the organic portion corresponds to 84%. There were 16% of waste that did not burn due to nitrogen atmosphere.

Page generated in 0.0595 seconds