• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 45
  • Tagged with
  • 45
  • 45
  • 40
  • 40
  • 17
  • 12
  • 10
  • 9
  • 9
  • 9
  • 8
  • 8
  • 7
  • 6
  • 6
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

"Estudo das resinas acrílicas para bases de próteses totais com relação à resistência flexural, e à quantidade de monômero residual superficial" / Study of acrylic resin for complete denture considering flexural strength and quantity of superficial residual mono mer

Tarcisio José de Arruda Paes Junior 16 June 2005 (has links)
O objetivo deste trabalho foi o de avaliar a resistência à flexão e a quantidade de monômero residual superficial em resinas acrílicas para bases de próteses totais. Para tanto foram confeccionados corpos-de-prova nas dimensões de 2.5mm x 10mm x 65mm, utilizados em ambas as análises. Padronizou-se o processo de inclusão no qual foram empregadas muflas plásticas reforçadas por fibras de vidro. Sete grupos foram constituídos, de acordo com o tipo de processamento empregado na polimerização das resinas: Ac (Acron-MC) e Vw (Vipi-Wave) de ativação por energia de microondas; Lt (Lucitone 550 – grupo controle) e Vc (Vipi-Cril), resinas de ativação térmica convencional em banho de água aquecida no ciclo longo; Qc (QC-20), uma resina de ativação térmica em ciclo rápido e, dois grupos cuja resina era a mesma de ativação química (Vipi-Flash), processada em duas condições – à temperatura ambiente (Vf1) e, por aquecimento adicional em banho de água (Vf2). Os resultados mostraram diferenças estatisticamente significantes, onde o grupo Ac obteve as maiores médias para resistência flexural e os menores níveis de monômero liberado em relação às demais resinas. Os grupos Qc e Vf1 evidenciaram os piores resultados para ambos os testes, e a princípio, pareceu haver uma relação de causa e efeito entre, os elevados níveis de monômero residual encontrado nestes grupos, e a baixa resistência flexural observada. Verificou-se ainda que a imersão em água aquecida por 30min, da resina de ativação química, propiciou um ganho em qualidade do material para as características avaliadas. / The purpose of this work was the evaluation of flexural strength and quantity of superficial residual monomer in acrylic resin for complete denture. To perform both analyses it was developed specimens with a dimension of 2.5mm x 10mm x 65mm. The inclusion process was standardized by the use of plastic flasks reinforced with fiberglass. Seven groups were constituted in accordance with the type of resin polymerization process: Ac (Acron-MC) and Vw (Vipi-Wave) activated by microwave energy; Lt (Lucitone 550 – control group) and Vc (Vipi-Cril), conventional water bath curing cycles of heat activated acrylic resin; Qc (QC-20), fast cycle thermal activation; and two groups of self cured resin (Vipi-Flash), processed in two distinguished conditions: ambient temperature (Vf1) and additional heating in water bath (Vf2). The results have shown statistical significant differences. The Ac group had the highest mean to flexural resistance and the least level of released monomer in comparison with others resins. The Qc and Vf1 groups had the worst results for both tests. The initial conclusions showed a cause-effect relation between higher levels of residual monomer and lower flexural strength to this group. Additionally, it was verified that the immersion for 30 minutes of self cured resin in heated water gave an improvement of material quality to evaluated characteristics.
22

Avaliação da liberação de monômero residual, absorção de água e porosidade superficial em resinas acrílicas para prótese ocular / Evaluation of residual monomer, water sorption and porosity by acrylic resins used to eye prostheses

Oliveira, Rodrigo Elias de 07 March 2008 (has links)
A necessidade do aprimoramento das técnicas de confecção de próteses oculares que permitam satisfazer, com rapidez e excelência, a demanda de atendimento de pacientes portadores de perdas do bulbo ocular, levou ao desenvolvimento deste estudo comparativo no qual se avalia a porosidade superficial, absorção de água e liberação de monômero residual de resinas acrílicas. Foram estabelecidos quatro grupos de estudo, sendo cada grupo composto por 15 corpos de prova: Grupo 1 - resina acrílica termo polimerizável convencional / ciclo térmico convencional; Grupo 2 - resina acrílica termo polimerizável em microondas / ciclo microondas; Grupo 3 - resina acrílica termo polimerizável convencional / ciclo microondas; Grupo 4 - resina acrílica auto polimerizável com cadeia cruzada / auto polimerização. A avaliação da quantidade de monômero residual liberado foi realizada por meio de espectrofotometria, durante o período de 11 dias. A determinação da absorção de água baseou-se na diferença do peso apresentado pelos corpos de prova nas condições experimentais seco e após submersão em água deionizada por um período de 7 dias. A determinação da porosidade superficial foi calculada sob a forma de porcentagem por área de superfície analisada, empregando-se lupa estereoscópica para captação da imagem a ser processada pelo software ImageLab 2000®. Submetendo-se os dados à análise estatística ANOVA/TUKEY (p<=0,05) observou-se que a liberação de monômero residual foi significantemente maior no primeiro dia para o Grupo 1, semelhante durante todo o período para o Grupo 2, menor a partir do dia 8 para o Grupo 3 e decrescente até o dia 8 para o Grupo 4. A liberação de monômero residual foi semelhante para os Grupos 1 e 3, menor para o Grupo 2 e maior para o Grupo 4. A absorção de água foi semelhante para os quatro grupos de estudo. A maior porosidade ocorreu no Grupo 2, sendo os Grupos 1 e 3 semelhantes entre si. Concluiu-se que os ciclos térmicos de polimerização em água e em microondas não interferiram na liberação de monômero residual da resina acrílica termo polimerizável convencional. A liberação de monômero residual variou em função do tipo de resina acrílica. O tipo de resina acrílica e o ciclo de polimerização a que foram submetidas não interferiram na absorção de água. Os ciclos térmicos de polimerização em água e em microondas não interferiram na porosidade apresentada pela resina acrílica termo polimerizável convencional. A porosidade superficial variou em função do tipo de resina acrílica avaliada. / This comparative evaluation of porosity, water sorption and residual monomer presented by acrylic resins was conducted, looking for excellence and rapidity in the confection of eye prostheses. Four groups, comprising of 15 specimens each, were established and submitted to polymerization cycles: Group 1 - conventional heat polymerizing acrylic resin / conventional heat-polymerization cycle; Group 2 - microwave acrylic resin / microwave cycle; Group 3 - conventional heat polymerizing acrylic resin / microwave cycle; Group 4 - cross-linked auto-polymerizing acrylic resin / auto-polymerizing process. Residual monomer liberation was determined by spectrophotometry during 11 days period. Water sorption was calculated by weighting dried specimens and weighting after 7 days of submersion in deionized water. Superficial porosity was determined by percentage of area, in images processed by the software ImageLab 2000®. Subjecting data to ANOVA/TUKEY test (p<=0,05) it was observed that residual monomer liberation was higher in the first day for Group 1, similar during all the period for Group 2, lower after day 8 for Group 3 and decreasing until day 8 for Group 4. Residual monomer liberation was similar to Groups 1 and 3, lower for Group 2 and higher for Group 4. Water sorption was similar to all groups. Group 2 displayed more superficial porosity, and Group 1 and 3 were similar regarding this test. In conclusion, conventional polymerization and microwave processes did not interfere in residual monomer liberation of conventional acrylic resin. The residual monomer liberation varied according the type of acrylic resin. Microwave cycle provided similar or smaller residual monomer liberation. The type of acrylic resin and the polymerization cycle utilized did not modify water sorption. The conventional heat polymerizing cycle and microwave cycle did not interfere in superficial porosity of conventional heat polymerizing acrylic resin. The superficial porosity varied according to the acrylic resin.
23

Avaliação dos efeitos adversos de soluções desinfetantes nas propriedades físicas e mecânicas de materiais para confecção de próteses totais / Evaluation of the adverse effects of disinfectant solutions on the physical and mechanical properties of materials for making complete dentures

Bueno, Frank Lucarini 23 January 2017 (has links)
O estudo avaliou os efeitos adversos de soluções desinfetantes sobre a dureza, alteração de cor, sorção e solubilidade, resistência à flexão, rugosidade e resistência ao impacto de uma resina acrílica e dentes artificiais. Microscopia confocal a laser foi utilizada para análise de superfície. Através da concentração inibitória mínima (CIM), utilizando o método de micro diluições, foi determinada a concentração de 0,15% para a solução de Triclosan e 0,25% para a Cloramina T. As variáveis foram mensuradas antes e após a imersão dos espécimes nas soluções. Os corpos de prova em resina acrílica termicamente ativada e os dentes artificiais foram distribuídos em grupos (n=10): GC = água destilada; GHS = Hipoclorito de sódio a 0,25%; GT = Solução de Triclosan a 0,15%; GCt = Solução de Cloramina T a 0,25%; GRc2 = solução de R. communis a 2%; GRc10 = solução de R. communis a 10%; GS = Sabonete Antisséptico. Os corpos de prova foram imersos em 100 mL de cada solução, simulando imersões diárias de 20 minutos por 5 anos. Os dados foram submetidos aos Testes ANOVA e Duncan ou ANOVA e Tukey (p=0,05). Para resina acrílica, todos os grupos diminuíram a dureza, tendo GC causado a maior diminuição (p=0,001). Nos demais grupos a diminuição da dureza foi semelhante. O grupo GRc2 apresentou a maior alteração de cor, enquanto o GCt causou a menor. Os demais grupos apresentaram valores intermediários (p=0,043). Em relação à sorção, o grupo GRc2 seguido do GC apresentaram maior valor de sorção e os grupos GT e GS, os menores. Para a solubilidade, os grupos GC, GHS, GCt, GT e GS apresentaram os maiores valores, e o grupo GRc2 seguido do GRc10 apresentou o menor valor (p=0,001). O menor valor de resistência a flexão foi verificado no GRc2, enquanto os grupos GC e GCt apresentaram os maiores valores (p=0,000). Os demais grupos apresentaram valores intermediários. Todas as soluções causaram diminuição da rugosidade exceto os grupos Rc10 e GC (p=0,001). Os grupos GS, GT e GCt apresentaram os maiores valores de resistência ao impacto, e o GRc10 apresentou o menor valor (p=0,000). Já para os dentes, houve aumento da dureza em todos os grupos, tendo os grupos GHS e GC causado maior alteração (p=0,000). Os grupos GS e GRc2 apresentaram a maior alteração de cor, enquanto os grupos GC, GCt e GT apresentaram as menores (p=0,000). Os grupos GC, GRc2 e GRc10 apresentaram os maiores valores de sorção e os grupos GT e GS os menores. Para a solubilidade, os grupos GRc10 e GRc2 apresentaram os maiores valores e os grupos GT e GS, os menores. A variação da rugosidade dos dentes indicou que todas as soluções causaram diminuição da rugosidade exceto o grupo GT. A maior variação de rugosidade foi causada pela solução de Rc10 (p=0,001). No período avaliado, todas as propriedades sofreram alterações em função das soluções de desinfecção avaliadas após simulação de imersões diárias de 20 minutos por 5 anos, porém todas as variáveis estudas apresentaram valores clinicamente aceitáveis, exceto a alteração de cor. / This study evaluated the adverse effects of disinfectant solutions on hardness, color change, sorption and solubility, flexural strength, roughness and impact strength of an acrylic resin and artificial teeth. Confocal laser microscopy was used for surface analysis. The minimum inhibitory concentration (MIC) using the microdilution method determined the concentration of 0.15% for the Triclosan solution and 0.25% for the Chloramine T. Variables were measured before and after immersion of the specimens in the solutions. The thermally activated acrylic resin specimens and the artificial teeth were distributed in groups (n = 10): GC = distilled water; GHS = 0.25% Sodium hypochlorite; GT = 0.15% Triclosan solution; GCt = 0.25% Chloramine T solution; GRc2 = 2% R. communis solution; GRc10 = 10% R. communis solution; GS = Antiseptic Soap. The specimens were immersed in 100 mL of each solution, simulating daily immersions of 20 minutes for 5 years. The data obtained were submitted to ANOVA and Duncan tests or ANOVA and Tukey tests (p = 0.05). For acrylic resin, all groups decreased hardness and GC showed the greatest decrease (p = 0.001). In the other groups the decrease in hardness was similar. The GRc2 group presented the greatest color change, while the GCt, the lowest. The other groups presented intermediate values (p = 0.043). In relation to the sorption, the GRc2 group followed by the GC presented higher sorption value and the GT and GS groups, the smaller. For solubility, GC, GHS, GCt, GT and GS presented the highest values, and the GRc2 group followed by GRc10 had the lowest value (p = 0.001). The GRc2 showed a lower value of flexural strength, while GC and GCt had the highest values (p = 0.000). The other groups presented intermediate values. All solutions caused a decrease in roughness except the groups Rc10 and GC (p = 0.001). The groups GS, GT and GCt had the highest values of impact resistance, and the GRc10 had the lowest value (p = 0.000). For the teeth, there were an increase on hardness in all groups, and the GHS and CG groups showed a greater change (p = 0.000). The GS and GRc2 groups had the highest color change, while the GC, GCt and GT groups showed the lowest (p = 0.000). The GC, GRc2 and GRc10 groups had the highest sorption values and the GT and GS groups had the lowest values. For the solubility, the GRc10 and GRc2 groups had the highest values and the GT and GS groups, the lowest. The variation of the roughness of the teeth indicated that all solutions caused a decrease in roughness except for the GT group. The highest roughness variation was caused by the Rc10 solution (p = 0.001). In the evaluated period, all the properties were altered as a function of the disinfection solutions evaluated after simulation of daily immersions of 20 minutes for 5 years, however all variables studied presented clinically acceptable values, except for color change.
24

Avaliação dos efeitos adversos de soluções desinfetantes nas propriedades físicas e mecânicas de materiais para confecção de próteses totais / Evaluation of the adverse effects of disinfectant solutions on the physical and mechanical properties of materials for making complete dentures

Frank Lucarini Bueno 23 January 2017 (has links)
O estudo avaliou os efeitos adversos de soluções desinfetantes sobre a dureza, alteração de cor, sorção e solubilidade, resistência à flexão, rugosidade e resistência ao impacto de uma resina acrílica e dentes artificiais. Microscopia confocal a laser foi utilizada para análise de superfície. Através da concentração inibitória mínima (CIM), utilizando o método de micro diluições, foi determinada a concentração de 0,15% para a solução de Triclosan e 0,25% para a Cloramina T. As variáveis foram mensuradas antes e após a imersão dos espécimes nas soluções. Os corpos de prova em resina acrílica termicamente ativada e os dentes artificiais foram distribuídos em grupos (n=10): GC = água destilada; GHS = Hipoclorito de sódio a 0,25%; GT = Solução de Triclosan a 0,15%; GCt = Solução de Cloramina T a 0,25%; GRc2 = solução de R. communis a 2%; GRc10 = solução de R. communis a 10%; GS = Sabonete Antisséptico. Os corpos de prova foram imersos em 100 mL de cada solução, simulando imersões diárias de 20 minutos por 5 anos. Os dados foram submetidos aos Testes ANOVA e Duncan ou ANOVA e Tukey (p=0,05). Para resina acrílica, todos os grupos diminuíram a dureza, tendo GC causado a maior diminuição (p=0,001). Nos demais grupos a diminuição da dureza foi semelhante. O grupo GRc2 apresentou a maior alteração de cor, enquanto o GCt causou a menor. Os demais grupos apresentaram valores intermediários (p=0,043). Em relação à sorção, o grupo GRc2 seguido do GC apresentaram maior valor de sorção e os grupos GT e GS, os menores. Para a solubilidade, os grupos GC, GHS, GCt, GT e GS apresentaram os maiores valores, e o grupo GRc2 seguido do GRc10 apresentou o menor valor (p=0,001). O menor valor de resistência a flexão foi verificado no GRc2, enquanto os grupos GC e GCt apresentaram os maiores valores (p=0,000). Os demais grupos apresentaram valores intermediários. Todas as soluções causaram diminuição da rugosidade exceto os grupos Rc10 e GC (p=0,001). Os grupos GS, GT e GCt apresentaram os maiores valores de resistência ao impacto, e o GRc10 apresentou o menor valor (p=0,000). Já para os dentes, houve aumento da dureza em todos os grupos, tendo os grupos GHS e GC causado maior alteração (p=0,000). Os grupos GS e GRc2 apresentaram a maior alteração de cor, enquanto os grupos GC, GCt e GT apresentaram as menores (p=0,000). Os grupos GC, GRc2 e GRc10 apresentaram os maiores valores de sorção e os grupos GT e GS os menores. Para a solubilidade, os grupos GRc10 e GRc2 apresentaram os maiores valores e os grupos GT e GS, os menores. A variação da rugosidade dos dentes indicou que todas as soluções causaram diminuição da rugosidade exceto o grupo GT. A maior variação de rugosidade foi causada pela solução de Rc10 (p=0,001). No período avaliado, todas as propriedades sofreram alterações em função das soluções de desinfecção avaliadas após simulação de imersões diárias de 20 minutos por 5 anos, porém todas as variáveis estudas apresentaram valores clinicamente aceitáveis, exceto a alteração de cor. / This study evaluated the adverse effects of disinfectant solutions on hardness, color change, sorption and solubility, flexural strength, roughness and impact strength of an acrylic resin and artificial teeth. Confocal laser microscopy was used for surface analysis. The minimum inhibitory concentration (MIC) using the microdilution method determined the concentration of 0.15% for the Triclosan solution and 0.25% for the Chloramine T. Variables were measured before and after immersion of the specimens in the solutions. The thermally activated acrylic resin specimens and the artificial teeth were distributed in groups (n = 10): GC = distilled water; GHS = 0.25% Sodium hypochlorite; GT = 0.15% Triclosan solution; GCt = 0.25% Chloramine T solution; GRc2 = 2% R. communis solution; GRc10 = 10% R. communis solution; GS = Antiseptic Soap. The specimens were immersed in 100 mL of each solution, simulating daily immersions of 20 minutes for 5 years. The data obtained were submitted to ANOVA and Duncan tests or ANOVA and Tukey tests (p = 0.05). For acrylic resin, all groups decreased hardness and GC showed the greatest decrease (p = 0.001). In the other groups the decrease in hardness was similar. The GRc2 group presented the greatest color change, while the GCt, the lowest. The other groups presented intermediate values (p = 0.043). In relation to the sorption, the GRc2 group followed by the GC presented higher sorption value and the GT and GS groups, the smaller. For solubility, GC, GHS, GCt, GT and GS presented the highest values, and the GRc2 group followed by GRc10 had the lowest value (p = 0.001). The GRc2 showed a lower value of flexural strength, while GC and GCt had the highest values (p = 0.000). The other groups presented intermediate values. All solutions caused a decrease in roughness except the groups Rc10 and GC (p = 0.001). The groups GS, GT and GCt had the highest values of impact resistance, and the GRc10 had the lowest value (p = 0.000). For the teeth, there were an increase on hardness in all groups, and the GHS and CG groups showed a greater change (p = 0.000). The GS and GRc2 groups had the highest color change, while the GC, GCt and GT groups showed the lowest (p = 0.000). The GC, GRc2 and GRc10 groups had the highest sorption values and the GT and GS groups had the lowest values. For the solubility, the GRc10 and GRc2 groups had the highest values and the GT and GS groups, the lowest. The variation of the roughness of the teeth indicated that all solutions caused a decrease in roughness except for the GT group. The highest roughness variation was caused by the Rc10 solution (p = 0.001). In the evaluated period, all the properties were altered as a function of the disinfection solutions evaluated after simulation of daily immersions of 20 minutes for 5 years, however all variables studied presented clinically acceptable values, except for color change.
25

Avaliação in vitro do efeito da incorporação de clorexidina nas propriedades físicas e na atividade antibacteriana de resinas acrílicas autopolimerizáveis / Effect of the incorporation of chlorhexidine in provisional crown and bridge acrylic resins on their physical properties

Gabriela Czauski Amaral de Rojas 01 February 2012 (has links)
Objetivo. O objetivo do presente estudo foi avaliar o efeito da incorporação de diacetato de clorexidina (CDA), em diferentes concentrações e tempos de armazenamento, nas propriedades físicas e na atividade antibacteriana de resinas acrílicas, utilizadas na confecção de coroas e pontes provisórias. Métodos. Fase I: Foram confeccionados 150 corpos de prova retangulares (3,0 mm X 10 mm X 64 mm), de acordo com a norma ISO 1567 e 150 corpos de prova quadrados (10 mm X 10 mm X 2,0 mm), utilizando-se duas resinas acrílicas autopolimerizáveis, Duralay (Reliance Dental Mfg. Co.) e Dencor (Clássico). Os corpos de prova foram distribuídos em 30 grupos (n=10/grupo) de acordo com a concentração de CDA incorporada às resinas (p/p) (A) 0%, (B) 1%, (C) 2%, (D) 4%, (E) 5%, em função do tempo de armazenamento em água destilada, a 37C (T0 2h, T1 7 dias, T2 30 dias). Foram realizados os ensaios de microdureza Knoop, em microdurômetro Micromet 5104, Buehler (N), rugosidade superficial (Ra), em rugosímetro digital Mitutoyo Surftest SJ-201 (n=5) e resistência à flexão em três pontos (MPa), em uma máquina de ensaio universal EMIC MF 200 DL (n=5). Fase II: Adicionalmente, a atividade antibacteriana dos materiais sobre Streptococcus mutans foi determinada através da realização de testes de difusão em meio BHI, sendo para isso confeccionados 30 corpos de prova em forma de disco (12 mm X 3,0 mm) com as mesmas 5 concentrações (n=3/grupo). Os resultados foram tabulados e submetidos à análise estatística three-way ANOVA (Fase I) e two-way ANOVA (Fase II). Resultados. ANOVA mostrou que a adição de CDA não provocou alteração significativa na resistência à flexão dos materiais testados. A resistência à flexão é inversamente proporcional ao tempo para a resina Dencor e diretamente proporcional ao tempo para a resina Duralay. Houve aumento da microdureza com o acréscimo de CDA ao material Dencor com relação ao grupo controle, enquanto que no material Duralay a CDA não interferiu significativamente nesta propriedade. A rugosidade superficial aumentou significativamente (p<0,001) com o tempo e com o aumento da concentração de clorexidina na resina Dencor e não provocou alteração significativa em Duralay. Os testes de difusão em ágar demonstraram atividade antimicrobiana significativa (p<0,05) em todos os grupos, quando comparados ao grupo-controle. A inibição ao crescimento de Streptococcus mutans foi maior com o aumento da concentração desta substância. A resina Dencor apresentou maior halo de inibição do que a resina Duralay. Conclusões. Os resultados deste estudo sugerem que a incorporação de clorexidina aos materiais testados exibiu efeito antibacteriano contra S. mutans, sem contudo afetar de maneira crítica as propriedades físicas avaliadas. / Objectives. This study evaluated the effect of the incorporation of chlorhexidine diacetate salt hydrate (CDA) on the hardness, roughness and flexural strength (FS) of provisional crown and bridge acrylic resins. Methods. Step I: One hundred fifty specimens (3,0 mm X 10 mm X 64 mm) and one hundred fifty specimens (10 mm X 10 mm X 2,0 mm) of the autopolymerizing resins: Duralay (Reliance Dental Mfg. Co.) and Dencor (Clássico) were prepared, according to the ISO 1567 specification. The specimens were divided into 30 groups (n=10/group) according to the concentration of CDA (w/w): (A) 1%, (B) 2%, (C) 4%, (D) 5%, (E) 0% and the storage time in distilled water at 37C, after mixing (T0 2h, T1 7 days, T2 30 days). The surface hardness was assessed using a Knoop Hardness test (KHN), the surface roughness measurements (Ra) were made using a surface roughness tester Mitutoyo Surftest SJ-201 (n=5) and the FS were tested using a 3-point bending test (n=5). Step II: Additionally, antibacterial study was performed by observing the presence of inhibition zone against Streptococcus mutans. For this test, 30 set disc-shaped specimens (12 mm X 3 mm) were prepared with the same 5 concentrations of chlorhexidine (n=3/group). Results. ANOVA showed that the addition of CDA had not a significantly lower effect on flexural strength of the tested materials. The flexural strength is inversely proportional to the time for Dencor and directly proportional for Duralay. There was a decrease of microhardness with the increase of CDA concentration on Dencor samples in relation to the control group, whereas the addition of CDA did not interfere in this property for Duralay. Surface roughness significantly increased (p<0,001) over time and increasing concentration of CDA for Dencor and did not cause significant change in Duralay. The agar diffusion test showed that all the tested groups had significant antibacterial activity against S. mutans, compared to the control group (p<0,05) and there were no difference between the resins. Increasing concentration of the substance produced greater inhibition. Conclusions. The results of this study suggested that the incorporation of CDA to the materials tested exhibited antibacterial effects against S. mutans, without compromising its physical properties.
26

EFEITO DO ACABAMENTO DE SUPERFÍCIE NA ESTABILIDADE DE COR DE RESINAS PARA PROVISÓRIO SUBMETIDAS A DESAFIO CORANTE / EFFECT OF SURFACE FINISHING ON COLOR STABILITY OF RESINS FOR PROVISIONALS SUBMITTED TO STAINING CHALLENGE

Garlet, Katia 25 August 2014 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / The purpose of this study was to investigate the effect of surface finishing on the color stability of the resins used for provisional restorations when immersed in staining agent in different times (7, 30, and 60 days). Thirty-six disc-shaped specimens (sp) were built up for each type of resin: Duralay (polymethylmethacrylate), Trim II (polyethylmethacrylate) and Protemp 4 (bis-acrylic). The sp were prepared using a muffle with the use of a matrix with dimensions of 10x3 mm. Resins were inserted in the muffle, pressed with 1500 kgf and sp were removed after 15 min. The sp were randomly divided into 2 groups: one was finished with 150-grit sandpaper (rough group) and the other with 150 to 1200-grit sandpapers sequence (polished group). These groups were subdivided into two types of immersion: red wine and saliva (control). Specimens from the wine group were immersed 10 minutes per day and were maintained in saliva along the remained period. Specimens from control group were kept in saliva which was changed every 3 days. The color change (ΔE) was measured with the spectrophotometer SP60 using the CIE L*a*b* system. Data were statistically analyzed by ANOVA and Tukey test (5%). The effect of surface, material and time was statistically significant in red wine (p <0.05). The methylmethacrylate-based resin was superior to the other materials in both storage media, in all periods and in polished and rough surfaces. / O objetivo deste trabalho foi investigar o efeito do acabamento de superfície na estabilidade de cor das resinas utilizadas para confecção de restaurações provisórias submetidas a desafio corante em períodos distintos (7, 30 e 60 dias). Foram confeccionados 36 corpos de prova (cps) em forma de disco para cada tipo de resina: Duralay (polimetilmetacrilato), Trim II (polietilmetacrilato) e Protemp 4 (bis-acril). Os cps foram confeccionados em mufla através de uma matriz com dimensões de 10x3 mm. As resinas foram inseridas na mufla, prensadas com 1500 kgf e os cps removidos após 15 min. Os cps foram aleatoriamente divididos em 2 grupos, sendo que um recebeu acabamento de superfície com lixa d água granulação 150 (grupo rugoso) e o outro acabamento com sequência de lixas de 150 a 1200 (grupo polido). Esses grupos foram subdivididos em dois tipos de imersão: vinho tinto e saliva (controle). Os cps do grupo vinho receberam imersões diárias de 10 minutos e no restante do tempo eram mantidos em saliva. Os cps do grupo controle permaneceram em saliva, que era renovada a cada 3 dias. A alteração de cor (ΔE*) foi medida pelo espectrofotômetro SP60 utilizando o sistema CIE L*a*b*. Os dados foram analisados estatisticamente através de Análise de Variância com fator vinculado e Teste de Tukey (5%). O efeito da superfície, material e tempo foi estatisticamente significante em vinho (p<0,05). A resina à base de metilmetacrilato mostrou superioridade nos dois meios de imersão, em todos os tempos e nas superfícies polida e rugosa.
27

Avaliação in vitro do efeito da incorporação de clorexidina nas propriedades físicas e na atividade antibacteriana de resinas acrílicas autopolimerizáveis / Effect of the incorporation of chlorhexidine in provisional crown and bridge acrylic resins on their physical properties

Gabriela Czauski Amaral de Rojas 01 February 2012 (has links)
Objetivo. O objetivo do presente estudo foi avaliar o efeito da incorporação de diacetato de clorexidina (CDA), em diferentes concentrações e tempos de armazenamento, nas propriedades físicas e na atividade antibacteriana de resinas acrílicas, utilizadas na confecção de coroas e pontes provisórias. Métodos. Fase I: Foram confeccionados 150 corpos de prova retangulares (3,0 mm X 10 mm X 64 mm), de acordo com a norma ISO 1567 e 150 corpos de prova quadrados (10 mm X 10 mm X 2,0 mm), utilizando-se duas resinas acrílicas autopolimerizáveis, Duralay (Reliance Dental Mfg. Co.) e Dencor (Clássico). Os corpos de prova foram distribuídos em 30 grupos (n=10/grupo) de acordo com a concentração de CDA incorporada às resinas (p/p) (A) 0%, (B) 1%, (C) 2%, (D) 4%, (E) 5%, em função do tempo de armazenamento em água destilada, a 37C (T0 2h, T1 7 dias, T2 30 dias). Foram realizados os ensaios de microdureza Knoop, em microdurômetro Micromet 5104, Buehler (N), rugosidade superficial (Ra), em rugosímetro digital Mitutoyo Surftest SJ-201 (n=5) e resistência à flexão em três pontos (MPa), em uma máquina de ensaio universal EMIC MF 200 DL (n=5). Fase II: Adicionalmente, a atividade antibacteriana dos materiais sobre Streptococcus mutans foi determinada através da realização de testes de difusão em meio BHI, sendo para isso confeccionados 30 corpos de prova em forma de disco (12 mm X 3,0 mm) com as mesmas 5 concentrações (n=3/grupo). Os resultados foram tabulados e submetidos à análise estatística three-way ANOVA (Fase I) e two-way ANOVA (Fase II). Resultados. ANOVA mostrou que a adição de CDA não provocou alteração significativa na resistência à flexão dos materiais testados. A resistência à flexão é inversamente proporcional ao tempo para a resina Dencor e diretamente proporcional ao tempo para a resina Duralay. Houve aumento da microdureza com o acréscimo de CDA ao material Dencor com relação ao grupo controle, enquanto que no material Duralay a CDA não interferiu significativamente nesta propriedade. A rugosidade superficial aumentou significativamente (p<0,001) com o tempo e com o aumento da concentração de clorexidina na resina Dencor e não provocou alteração significativa em Duralay. Os testes de difusão em ágar demonstraram atividade antimicrobiana significativa (p<0,05) em todos os grupos, quando comparados ao grupo-controle. A inibição ao crescimento de Streptococcus mutans foi maior com o aumento da concentração desta substância. A resina Dencor apresentou maior halo de inibição do que a resina Duralay. Conclusões. Os resultados deste estudo sugerem que a incorporação de clorexidina aos materiais testados exibiu efeito antibacteriano contra S. mutans, sem contudo afetar de maneira crítica as propriedades físicas avaliadas. / Objectives. This study evaluated the effect of the incorporation of chlorhexidine diacetate salt hydrate (CDA) on the hardness, roughness and flexural strength (FS) of provisional crown and bridge acrylic resins. Methods. Step I: One hundred fifty specimens (3,0 mm X 10 mm X 64 mm) and one hundred fifty specimens (10 mm X 10 mm X 2,0 mm) of the autopolymerizing resins: Duralay (Reliance Dental Mfg. Co.) and Dencor (Clássico) were prepared, according to the ISO 1567 specification. The specimens were divided into 30 groups (n=10/group) according to the concentration of CDA (w/w): (A) 1%, (B) 2%, (C) 4%, (D) 5%, (E) 0% and the storage time in distilled water at 37C, after mixing (T0 2h, T1 7 days, T2 30 days). The surface hardness was assessed using a Knoop Hardness test (KHN), the surface roughness measurements (Ra) were made using a surface roughness tester Mitutoyo Surftest SJ-201 (n=5) and the FS were tested using a 3-point bending test (n=5). Step II: Additionally, antibacterial study was performed by observing the presence of inhibition zone against Streptococcus mutans. For this test, 30 set disc-shaped specimens (12 mm X 3 mm) were prepared with the same 5 concentrations of chlorhexidine (n=3/group). Results. ANOVA showed that the addition of CDA had not a significantly lower effect on flexural strength of the tested materials. The flexural strength is inversely proportional to the time for Dencor and directly proportional for Duralay. There was a decrease of microhardness with the increase of CDA concentration on Dencor samples in relation to the control group, whereas the addition of CDA did not interfere in this property for Duralay. Surface roughness significantly increased (p<0,001) over time and increasing concentration of CDA for Dencor and did not cause significant change in Duralay. The agar diffusion test showed that all the tested groups had significant antibacterial activity against S. mutans, compared to the control group (p<0,05) and there were no difference between the resins. Increasing concentration of the substance produced greater inhibition. Conclusions. The results of this study suggested that the incorporation of CDA to the materials tested exhibited antibacterial effects against S. mutans, without compromising its physical properties.
28

Avaliação da liberação de monômero residual, absorção de água e porosidade superficial em resinas acrílicas para prótese ocular / Evaluation of residual monomer, water sorption and porosity by acrylic resins used to eye prostheses

Rodrigo Elias de Oliveira 07 March 2008 (has links)
A necessidade do aprimoramento das técnicas de confecção de próteses oculares que permitam satisfazer, com rapidez e excelência, a demanda de atendimento de pacientes portadores de perdas do bulbo ocular, levou ao desenvolvimento deste estudo comparativo no qual se avalia a porosidade superficial, absorção de água e liberação de monômero residual de resinas acrílicas. Foram estabelecidos quatro grupos de estudo, sendo cada grupo composto por 15 corpos de prova: Grupo 1 - resina acrílica termo polimerizável convencional / ciclo térmico convencional; Grupo 2 - resina acrílica termo polimerizável em microondas / ciclo microondas; Grupo 3 - resina acrílica termo polimerizável convencional / ciclo microondas; Grupo 4 - resina acrílica auto polimerizável com cadeia cruzada / auto polimerização. A avaliação da quantidade de monômero residual liberado foi realizada por meio de espectrofotometria, durante o período de 11 dias. A determinação da absorção de água baseou-se na diferença do peso apresentado pelos corpos de prova nas condições experimentais seco e após submersão em água deionizada por um período de 7 dias. A determinação da porosidade superficial foi calculada sob a forma de porcentagem por área de superfície analisada, empregando-se lupa estereoscópica para captação da imagem a ser processada pelo software ImageLab 2000®. Submetendo-se os dados à análise estatística ANOVA/TUKEY (p<=0,05) observou-se que a liberação de monômero residual foi significantemente maior no primeiro dia para o Grupo 1, semelhante durante todo o período para o Grupo 2, menor a partir do dia 8 para o Grupo 3 e decrescente até o dia 8 para o Grupo 4. A liberação de monômero residual foi semelhante para os Grupos 1 e 3, menor para o Grupo 2 e maior para o Grupo 4. A absorção de água foi semelhante para os quatro grupos de estudo. A maior porosidade ocorreu no Grupo 2, sendo os Grupos 1 e 3 semelhantes entre si. Concluiu-se que os ciclos térmicos de polimerização em água e em microondas não interferiram na liberação de monômero residual da resina acrílica termo polimerizável convencional. A liberação de monômero residual variou em função do tipo de resina acrílica. O tipo de resina acrílica e o ciclo de polimerização a que foram submetidas não interferiram na absorção de água. Os ciclos térmicos de polimerização em água e em microondas não interferiram na porosidade apresentada pela resina acrílica termo polimerizável convencional. A porosidade superficial variou em função do tipo de resina acrílica avaliada. / This comparative evaluation of porosity, water sorption and residual monomer presented by acrylic resins was conducted, looking for excellence and rapidity in the confection of eye prostheses. Four groups, comprising of 15 specimens each, were established and submitted to polymerization cycles: Group 1 - conventional heat polymerizing acrylic resin / conventional heat-polymerization cycle; Group 2 - microwave acrylic resin / microwave cycle; Group 3 - conventional heat polymerizing acrylic resin / microwave cycle; Group 4 - cross-linked auto-polymerizing acrylic resin / auto-polymerizing process. Residual monomer liberation was determined by spectrophotometry during 11 days period. Water sorption was calculated by weighting dried specimens and weighting after 7 days of submersion in deionized water. Superficial porosity was determined by percentage of area, in images processed by the software ImageLab 2000®. Subjecting data to ANOVA/TUKEY test (p<=0,05) it was observed that residual monomer liberation was higher in the first day for Group 1, similar during all the period for Group 2, lower after day 8 for Group 3 and decreasing until day 8 for Group 4. Residual monomer liberation was similar to Groups 1 and 3, lower for Group 2 and higher for Group 4. Water sorption was similar to all groups. Group 2 displayed more superficial porosity, and Group 1 and 3 were similar regarding this test. In conclusion, conventional polymerization and microwave processes did not interfere in residual monomer liberation of conventional acrylic resin. The residual monomer liberation varied according the type of acrylic resin. Microwave cycle provided similar or smaller residual monomer liberation. The type of acrylic resin and the polymerization cycle utilized did not modify water sorption. The conventional heat polymerizing cycle and microwave cycle did not interfere in superficial porosity of conventional heat polymerizing acrylic resin. The superficial porosity varied according to the acrylic resin.
29

Efeito da triazina nas propriedades mecânicas e formação de biofilme em resina acrílica e reembasadores de prótese / Antimicrobial activity of triazine added to denture materials on saliva-derived microcosms: microbiological efficacy and mechanical properties

Moraes, Aline Pinheiro de 01 April 2011 (has links)
Made available in DSpace on 2014-08-20T14:30:16Z (GMT). No. of bitstreams: 1 Dissertacao_Aline Pinheiro_Moraes.pdf: 846337 bytes, checksum: 66b01044077d89e98213868cd5b7582a (MD5) Previous issue date: 2011-04-01 / Candidiasis is the most common fungal infection in denture wearers. The association between Candida and denture base is directly related to the efficiency of this micro-organism to adhere and colonize these surfaces, which is an essential initial step for the development of denture-related stomatitis. Additionally, the use of denture liners has increased, with these materials more prone to microbial adhesion when compared with acrylic resin due to its higher surface roughness. These materials have demonstrated capacity to interact with oral micro-organisms.This important problem is the reason why several attempts have been made to develop biomaterials containing antifungal. Thus, the aim of this study was to investigate the potential antifungal activity of triazine added to acrylic resin and liners used in prosthodontics using microcosms biofilm model with saliva derived from patients with or without candidiasis, verifying its effectiveness in reducing microbial adherence and consequently reduce the incidence of Candida infections. The mechanical properties of the tested materials after the incorporation of triazine were also evaluated. We considered four commercially available materials (a microwave-cured acrylic resin and two soft denture liners and one hard denture liner) to which were added different concentrations of triazine (0; 2.5; 5.0 and 10%). The results indicated that no difference were found among triazine concentrations in acrylic resin flexural strength (p= 0.059). Triazine addition did not result in surface roughness changes, although all denture liners presented higher surface roughness compared with acrylic resin, while in general, SoftConfort presented the highest roughness (p<0.001). In general, 5 and 10% triazine addition resulted in more soluble materials. All materials presented increased water sorption with the addition of triazine (p<0.05), except for CoeSoft, where no change was observed. Candidiasis patient saliva presented higher counts of total micro-organisms (p= 0.0294) and total streptococci (p = 0.0008). Regarding materials, total streptococci, total micro-organisms and Candida counts were higher in CoeSoft (p<0.0001). Candida species counts was the same for both saliva donors (p>0.05). The addition of triazine did not result in decrease of total micro-organisms, total streptococci or Candida species in all materials tested (p>0.05). In conclusion, the addition of triazine to acrylic resin and denture liners in a complex biofilm model did not modify the development of biofilms in both patients with and without candidiasis / A candidíase é a infecção oral fúngica mais comum em usuários de próteses. A associação entre o microrganismo Candida e as bases das próteses está diretamente relacionada à eficiência deste microrganismo em aderir e colonizar estas superfícies, sendo esta a etapa inicial essencial para o desenvolvimento da estomatite induzida por prótese. Associado a isto, o uso de reembasadores para próteses tem aumentado, sendo estes materiais mais propensos à adesão microbiana quando comparados a resina acrílica devido a sua maior rugosidade de superfície. Além disso, estes materiais tem demonstrado capacidade de interagir com microrganismos bucais. Este importante problema tem levado a tentativa de desenvolvimento de diversos materiais contendo agentes antifúngicos. Assim, o objetivo deste estudo foi investigar o potencial antifúngico da triazina adicionada à resina acrílica e reembasadores utilizados em prótese dentária, através de um modelo de biofilme de microcosmos, com salivas derivadas de pacientes com ou sem candidíase, verificando sua efetividade em reduzir a adesão microbiana e, consequentemente, diminuir a incidência de infecções por Candida. Também avaliaram-se as propriedades mecânicas dos materiais testados após a incorporação da triazina. Foram considerados quatro materiais comercialmente disponíveis (uma resina acrílica ativada por energia de micro-ondas, dois reembasadores resilientes e um reembasador permanente), aos quais foram adicionadas diferentes concentrações de triazina (0; 2,5; 5,0 e 10%). Os resultados indicaram que não houve diferença (p = 0,059) entre as concentrações de triazina para a resina acrílica de micro-ondas no teste de resistência à flexão. Em relação a rugosidade de superfície, embora a adição de triazina não tenha levado ao aumento da rugosidade, os reembasadores apresentaram maior rugosidade que a resina acrílica, com o SoftConfort apresentando, em geral, a maior rugosidade (p<0,001). De maneira geral, quando adicionada triazina a 5,0 e 10%, todos os materiais tornaram-se mais solúveis e apresentaram aumento de sorção de água (p<0,05), a exceção do CoeSoft, que não mostrou diferença com a adição do composto químico. Houve diferença entre salivas, sendo que aquela proveniente de individuo com candidíase apresentou maiores contagens de microrganismos totais (p = 0,0294) e estreptococos totais (p = 0,0008). Em relação aos materiais, a contagem de estreptococos, microrganismos totais e espécies de Candida foi maior no CoeSoft (p<0,0001). Entretanto, a contagem de espécies de Candida foi igual entre os doadores (p>0,05). A adição de triazina não resultou em diminuição de microrganismos totais, estreptococos totais ou espécies de Candida em nenhum dos materiais testados (p>0,05). Como conclusão, a adição de triazina a resina acrílica e reembasadores utilizados para confecção de base e reembasamento de próteses em um modelo complexo de biofilme não modificou o desenvolvimento de biofilmes em ambos os pacientes com ou sem candidíase
30

EFEITO DE SOLUÇÕES HIGIENIZADORAS NA ESTABILIDADE DE COR E RUGOSIDADE DE RESINAS ACRÍLICAS PARA BASE DE DENTADURA / EFFECT OF CLEANING SOLUTIONS ON THE COLOR STABILITY AND ROUGHNESS OF DENTURE BASE ACRYLIC RESINS

Nora, Bárbara Dala 21 July 2016 (has links)
The aim of the study was to evaluate the effect of cleaning substances in color stability and roughness of acrylic resins to base definitive or provisional dentures polymerized by different methods. The factors evaluated were the type of acrylic resin (autopolymerized, heat-polymerized or microwave-polymerized), immersion media (alkaline peroxide, 0,5% sodium hypochlorite or artificial saliva as control) and time. Seventy-two disc-shaped specimens (8mmx2mm) were prepared (n = 8) and divided according to the experimental design. To determine color change (ΔE00) was used CIEDE2000 equation. The Ra parameter was used to determine the surface roughness of the samples. Baseline measurements were performed 24 hours after hydration (T0) and then the cps were subjected to 20 minutes daily immersions in media. New readings were performed in 30 (T1), 60 (T2) and 90 days (T3). Data were submitted to Analysis of Variance Test for Repeated Measures (Two-way ANOVA) followed by Tukey s Test (p <0,05). Significant effect was found over time, especially in color values (T2 and T3) and roughness for the autopolymerized resin (T3), which behaved worse. The solutions influenced color and roughness. Color stability and roughness were modified by means of immersion and varied depending on the type of polymerization, however the protocol of 20 minutes of immersion in cleaning solutions proved to be safe within the evaluated period for heat-polymerized and microwave-polymerized resin. / O objetivo do estudo foi avaliar o efeito substâncias de higienização na estabilidade de cor e na rugosidade de resinas acrílicas para base de dentadura definitiva ou provisória, polimerizadas por diferentes métodos. Os fatores avaliados foram o tipo de resina acrílica (autopolimerizável, termopolimerizável ou cura por micro-ondas), meios de imersão (peróxido alcalino, hipoclorito de sódio a 0,5% ou saliva artificial como controle) e tempo. Setenta e dois corpos de prova (cps) em forma de disco (8mmx2mm) foram confeccionados (n=8) e divididos conforme delineamento experimental. Para determinar alteração de cor (ΔE00) foi utilizada a equação CIEDE2000. O parâmetro de Ra foi empregado para determinar a rugosidade superficial média das amostras. As mensurações iniciais foram feitas 24h após a hidratação (T0) e a seguir os cps foram submetidos a imersões diárias de 20 minutos nos meios. Novas leituras foram realizadas nos tempos de 30 (T1),60 (T2) e 90 dias (T3). Os dados foram submetidos à Análise de Variância com dois fatores para Medidas Repetidas seguido de Teste de Tukey (p<0,05). Efeito significativo foi encontrado ao longo do tempo, principalmente nos valores de cor (T2 e T3) e rugosidade da resina autopolimerizável (T3), a qual se comportou de maneira inferior. Os meios influenciaram cor e rugosidade. Estabilidade de cor e rugosidade foram modificadas pelos meios de imersão e variaram conforme o tipo de polimerização, porém o protocolo de imersão em 20 minutos nas soluções higienizadoras mostrouse seguro dentro do período avaliado para as resinas termopolimerizável e cura por micro-ondas.

Page generated in 0.0733 seconds