• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 52
  • Tagged with
  • 52
  • 52
  • 41
  • 18
  • 15
  • 14
  • 13
  • 12
  • 10
  • 10
  • 10
  • 10
  • 10
  • 9
  • 9
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
41

ANÁLISE DE SOBREVIDA E RESISTÊNCIA À FRATURA DE RAÍZES FRAGILIZADAS RESTAURADAS COM DIFERENTES PINOS INTRARRADICULARES / SURVIVAL ANALYSIS AND FRACTURE RESISTANCE OF WEAKENED ROOTS RESTORED WITH DIFFERENT SYSTEMS POSTS

Wandscher, Vinicius Felipe 23 March 2012 (has links)
Conselho Nacional de Desenvolvimento Científico e Tecnológico / Objectives: To evaluate the survival analysis and the fracture resistance of weakened (W) and not weakened (NW) roots restored with different intracanal systems posts. Methods: Eighty teeth were sectioned in 16mm and prepared in 12mm with a custom drill. Fifty roots were weakened with a tapered diamond drill and 30 kept without weakening. The specimens were embedded with acrylic-resin in PVC cylinders until 3mm coronal (bone limit) and the periodontal ligament was simulated with polyether material. The experimental design was: G1 and G2: cast and post core (Golden Alloy) with (CPC-GL W) or without (CPC GL NW) weakened roots, respectively; G3 and G4: cast and post core (Ni-Cr alloy) with (CPC Ni W) or without (CPC Ni NW) weakened roots, respectively; G5 and G6: fiber-posts with (FP NW) or without (FP W) weakened roots; G7: fiber-posts especially designed for weakened roots (FP-E W); G8: fiber-posts relined with composite-resin for weakened roots (FP-CR). All posts were adhesively cemented. All of the restored specimens were submitted to the mechanical cycling (37ºC, 45º, 130N, 2.2Hz and 1.5 million pulses) and follow up intervals between cycles 5x104 evaluating the presence of the event "crack". The specimens that survived the mechanical cycling were subjected to the fracture-resistance test under load application on palatal zone at 45º-inclination (cross-head speed = 1 mm/min) until failure. Failure mode was classified in favorable (above the simulated bone limit) and catastrophic (below the simulated bone limit). Survival rates were estimated using the technique of Kaplan-Meier method and survival rates according to the study groups were analyzed using the log-rank test (p≤0.05). Fracture resistance data were analyzed by the one-way ANOVA and Tukey test (p=0.05). Results: The post-hoc comparisons showed differences between specimens in groups FP-E and CPC (p=0.004). For fracture resistance statistical differences (p<0.0001) were depicted among the weakened groups: CPC-GL 541.4227.4A, CPC-Ni 642.6219.5A, FP- 282.264.7B, FP-E- 274.151.3B, FP-RC- 216.663.6B. No differences were observed for groups without weakening: CPC-GL- 459.3111.1A, CPC-Ni- 422.0151.9A and FP- 347.991.8A, with majority of favorable failures. Conclusions: weakened roots restored with CPC promoted high values of fracture toughness and failure rates unfavorable. There was higher survival rate for FP-E in relation to CPC (GL / Ni). / Objetivos: Avaliar a sobrevida e a resistência à fratura de raízes fragilizadas e não fragilizadas restauradas com diferentes pinos intracanais. Métodos: oitenta incisivos bovinos foram seccionados em 16 mm e preparados em 12 mm com brocas padronizadas. 50 raízes foram fragilizadas com ponta diamantada mantendo 0,5 mm de espessura e 6 mm intra canal e 30 foram mantidas sem fragilização. Os espécimes foram embutidos em cilindros de PVC até 3 mm coronários (limite ósseo) e o ligamento periodontal foi simulado com poliéter. A divisão dos grupos foi: G1 e G2, núcleo metálico fundido (liga nobre) com (NMF-LN FRAG) e sem (NMF-LN NFRAG) fragilização, respectivamente; G3 e G4: núcleo metálico fundido (liga não nobre) com (NMF-LNN FRAG) e sem (NMF-LNN NFRAG) fragilização, respectivamente; G5 e G6: pino de fibra de vidro com (PFV FRAG) e sem (PFV NFRAG) fragilização, respectivamente; G7: pinos de fibra especiais para canais alargados (PFV-E FRAG) e G8: pinos de fibra re-embasados com resina composta (PA FRAG). Todos os pinos foram cimentados adesivamente. Os espécimes foram submetidos à ciclagem mecânica (37ºC, 45º, 130N, 2.2Hz e 1.5x106 ciclos) e acompanhados entre intervalos de 5x104 ciclos quanto à presença do evento trinca . Os espécimes que sobreviveram foram submetidos ao teste de resistência à fratura sob aplicação de carga na face palatina da coroa (45º e 1 mm/min) até a falha. O modo de falha foi classificado em favorável (acima do limite ósseo simulado) e desfavorável (abaixo do limite ósseo simulado). As taxas de sobrevida foram estimadas pela curva de Kaplan-Meier e as taxas de sobrevivência de acordo com os grupos de estudo foram analisadas através do teste log-rank (p≤0,05). Os dados de resistência à fratura foram analisados pelo teste de ANOVA 1 fator e Tukey (p=0,05). Resultados: para análise de sobrevida, 7 espécimes fraturaram durante a ciclagem mecânica (grupos FRAG: 2 fraturas para PFV, 1 para NMF-LN e 2 para PA, grupos NFRAG: 2 para PFV). As comparações post-hoc demonstraram diferença apenas entre os espécimes dos grupos PFV-E e NMF (p=0,004). Para resistência à fratura houve diferença estatística (p<0.0001) entre os grupos fragilizados: G1- 541,4227,4A, G3- 642,6219,5A, G5- 282,264,7B, G7- 274,151,3B, G8- 216,663,6B com predominância de falhas desfavoráveis. Conclusão: Observou-se maior taxa de sobrevida para PFV-E em relação aos NMF (LN/LNN). Quanto ao teste de resistência à fratura, as raízes fragilizadas restauradas com núcleos metálicos fundidos apresentaram pior comportamento em relação às raízes restauradas com pinos de fibra de vidro (PFV, PFV-E e PA).
42

Resistência à fratura, padrão de fratura e deformação de raízes com canais excessivamente alargados restaurados com diferentes pinos e técnicas - avaliação mecânica e por extensometria

Silva, Gisele Rodrigues da 26 February 2007 (has links)
Fundação de Amparo a Pesquisa do Estado de Minas Gerais / The widening of the root canal increases its fracture risk and is not clear yet, the influence of the materials and techniques used to restore these teeth. The aim of this study was to evaluate the effect of different posts and restorative techniques in the fracture resistance, fracture mode and root strain in canals excessively widened. One hundred thirty five standardized bovine roots, with similar dimensions and endodontically treated, were randomly divided in 9 groups (n=15) with the root canals prepared with 10 mm depth and 1.5 mm diameter. All roots received ferrule in the coronal ending with 0.5 mm depth and 2 mm extension. The roots of two reference groups were reconstructed with nickel-chromium metallic cast post-and-core (NMF) and glass fiber post (PFV) with composite resin core. For the experimental groups (weakened roots - wc groups), the root canals were over prepared additionally with the depth of 9 mm and the diameter increased to approximately 3,5 mm. Then the roots were restored with metallic cast post-and-core (wcNMF); glass fiber post (wcPFV); glass fiber post associated with accessory glass - ap - fiber post (wcPFVap); direct composite resin - cr - in the medial and cervical thirds after luting the post (wcPFVcr); direct composite resin associated with accessory posts in the medial and cervical thirds, after luting the post (wcPFVcrap); the post was reembased indirectly with composite resin - icr - (wcPFVicr); the post was reembased indirectly with composite resin associated with accessory posts (wcPFVicrap). All posts were fixed with chemical resinous cement, the core was made with composite resin and the roots restored with metallic crown. The samples were submitted to 3x105 mechanical fatigue cycles of 50 N load and fracture resistance measured in a mechanical testing machine with tangential load application (135º). Five samples of each group received two strain gauges adhered in the mesial and buccal surfaces of the root, 1mm below the cervical crown ending, in the center of the tooth, to measure roots strain under continuous 0 to 100 N loading. Fracture mode was classified in accordance to the degree of destruction of the dental structure, in catastrophic or repairable. The data were submitted to ANOVA (2x2)l to one-way and Tukey´s test (&#945;=0.05). The factorial analysis demonstrated significant decrease of the fracture resistance and catastrophic failures for the wcNMF group. Roots widened canals restored with composite resin and/or accessory fiber posts result in fracture resistance values similar to NMF group, however, these demonstrated more repairable fracture. The strain-gauge analysis didn t present significant differences in the superficial strain of the root. Fiber glass post associated with composite resin or with accessory fiber glass posts, seems to be more indicated as alternative to metallic cast post-and-core in weakened roots, because of the lower risk of catastrophic fractures. / O alargamento do canal aumenta o risco de fratura dentária e ainda não está clara a influência dos materiais e técnicas empregados para restaurar dentes com estas características. Assim, o objetivo deste estudo foi avaliar o efeito de diferentes pinos e técnicas restauradoras na resistência à fratura, padrão de fratura e deformação de raízes com canais excessivamente alargados. Foram empregadas 135 raízes bovinas com dimensões semelhantes, tratadas endodonticamente, aleatoriamente divididas em 9 grupos (n= 15). Os canais foram preparados com 10 mm de profundidade e 1,5 mm de diâmetro e as raízes receberam preparo com férula de 0,5 mm de profundidade e 2 mm de extensão. Dois grupos de referência foram restaurados com retentores intraradiculares metálicos fundidos em níquel-cromo (NMF) e pino de fibra de vidro (PFV) com núcleo de preenchimento em resina composta. Para os demais grupos, os canais radiculares foram alargados na profundidade de 9 mm e o diâmetro aumentado para ±3,5 mm, padronizando a espessura de dentina remanescente em 0,5mm no terço coronário da raiz. Os canais alargados (ca) foram então restaurados com, núcleo metálico fundido (caNMF); pino de fibra de vidro (caPFV); pino de fibra de vidro associado a pinos de fibra de vidro acessórios (caPFVpa); preenchimento direto com resina composta nos terços médio e cervical após cimentação do pino (caPFVrd); preenchimento direto com resina composta associado a pinos acessórios, após cimentação do pino (caPFVrdpa); pino reembasado com resina composta de forma indireta (caPFVri); pino reembasado com resina composta de forma indireta associado a pinos acessórios (caPFVripa). Todos os procedimentos de cimentação foram realizados com cimento resinoso de ativação química, os núcleos de preenchimento em resina composta e as raízes restauradas com coroa total metálica. As amostras foram submetidas a 3x105 ciclos de fadiga mecânica de 50N de carga. Em cinco amostras de cada grupo, dois extensômetros foram aderidos à raiz, um na mesial e outro na vestibular, 1 mm abaixo do limite cervical da coroa, no centro do dente, para mensurar a deformação das raízes sob carregamento contínuo de 0 a 100N. A resistência à fratura (N) das amostras foi então medida em máquina de ensaio mecânico com aplicação de carga tangencial (135º). Os dados foram submetidos à análise de variância fatorial (2x2), para comparar o efeito do tipo de retentor em função do tipo de raiz, e em fator único, para avaliar os métodos de preenchimento, seguido pelo teste de Tukey (&#945;=0,05). O padrão de fratura foi classificado de acordo com o grau de comprometimento da estrutura dentária em catastrófica ou reparável. A análise estatística fatorial demonstrou significativa redução da resistência à fratura e falhas catastróficas para o grupo caNMF. Valores de resistência comparável ao grupo NMF e padrão de fratura reparável foram obtidos em raízes com canais alargados, sempre que a resina composta ou pinos de fibra acessórios foram utilizados. Não houve diferença significante na deformação externa da raiz entre os grupos estudados. Pode-se concluir que o uso de pinos de fibra de vidro, associado ao preenchimento com resina composta e/ou pinos de fibra de vidro acessórios, parece ser mais indicado como alternativa ao núcleo metálico fundido em raízes fragilizadas, devido ao menor risco de fraturas catastróficas. / Mestre em Odontologia
43

Influência da configuração do preparo cavitário na resistência à fratura e adaptação marginal de restaurações indiretas em cerômero

Fonseca, Rodrigo Borges 30 March 2004 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / The aim of this study was to evaluate the influence of cavity preparation design on marginal adaptation and fracture resistance of indirect ceromer restorations. Ninety human mandibular molars with similar dimensions were divided into 9 groups. The teeth roots were embedded in a polystyrene resin reproducing the periodontal ligament. The control group had only intact teeth and the other teeth received the following cavity preparations: 2) conservative inlay; 3) extensive inlay; 4) conservative oclusal isthmus onlay with mesio-buccal cusp coverage; 5) extensive oclusal isthmus onlay with mesio-buccal cusp coverage; 6) conservative onlay with buccal cusps coverage; 7) extensive onlay with buccal cusps coverage; 8) conservative overlay; 9) extensive overlay. Prepared teeth were restored with a ceromer material, Targis (Ivoclar-Vivadent). Silicon impressions of prepared teeth were taken; the indirect restorations were manufactured and then adhesively fixed on each tooth. The teeth were submitted to an ultimate compressive strength test on a universal testing machine, EMIC DL-2000, at a crosshead speed of 0,5mm/min. The modes of fractures were classified according to four levels of tooth final damage. Data were submitted to statistical analysis by ANOVA (&#945;=0,05) following Tukey test (95% confidence intervals) or Fisher LSD test (99% confidence intervals), and Pearson correlation coefficient. Fracture resistance results failed to show differences among all groups of prepared teeth, but showed difference between prepared teeth and control group (P=0,000). Two-way ANOVA also failed to show any particular difference when considering the oclusal isthmus width alone (P=0,980) or cuspal coverage (P=0,273), or even the interaction between these factors (P=0,972). A great number of teeth had a harmful mode of fracture, which extended till the biological width. Marginal adaptation results showed differences among the prepared teeth (P=0,005). G3 showed the best marginal adaptation and G2 the worst one. Two-way ANOVA showed particular differences when considering the oclusal isthmus width alone (P=0,001): in general, extensive oclusal isthmus preparations presented better results than conservative ones; however, the test failed to show differences when considering the cuspal coverage (P=0,425) or the interaction between both factors (P=0,301). Pearson correlation coefficient showed significance only on G7. The absence of differences on fracture resistance among prepared teeth and their fracture modes clear show the adhesive capacity of this restorative treatment; thus it seems not to be necessary cuspal coverage when tooth preparations are similar to the ones of this study. Best marginal adaptation of extensive oclusal isthmus preparations over conservative ones seems to be related to the reduced necessity of internal restoration adjustment. / Este estudo avaliou a influência da configuração do preparo cavitário na adaptação marginal e resistência à fratura de molares com restaurações indiretas em cerômero. Noventa molares inferiores humanos hígidos com configurações geométricas semelhantes, foram divididos em nove grupos. Os dentes foram incluídos em cilindros de resina de poliestireno, simulando o ligamento periodontal. Um grupo foi constituído por dentes íntegros, e os outros grupos receberam os seguintes tipos de preparos: 2) inlay conservador; 3) inlay extenso; 4) onlay com abertura conservadora recobrindo a cúspide mésio-vestibular; 5) onlay com abertura extensa recobrindo a cúspide mésio-vestibular; 6) onlay com abertura conservadora recobrindo todas as cúspides vestibulares; 7) onlay com abertura extensa recobrindo todas as cúspides vestibulares; 8) overlay com abertura conservadora recobrindo todas as cúspides; 9) overlay com abertura extensa recobrindo todas as cúspides. Cada grupo foi restaurado com cerômero, Targis (n= 10). Os dentes foram moldados, as restaurações em cerômero confeccionadas e então fixadas. Os dentes foram adaptados à máquina de ensaio universal, EMIC DL-2000, e os testes de compressão axial efetuados com velocidade de 0,5 mm/minuto, até a fratura do conjunto (dente/restauração). O padrão de fratura foi analisado classificando o tipo de fratura em quatro níveis de comprometimento progressivo. Os dados obtidos nos testes de resistência à fratura foram submetidos à análise estatística empregando análise de variância (&#945;=0,05), teste de Tukey, em intervalo de confiança de 95%, teste de Fisher para comparações múltiplas, em intervalo de confiança de 99%, e teste de correlação de Pearson. Os resultados de resistência à fratura demonstraram diferença significante entre o grupo controle e os grupos preparados, sendo que todos os grupos preparados apresentaram-se semelhantes (P=0,000). Não houve diferença entre os grupos preparados para o fator abertura de caixa oclusal (P=0,980), ou recobrimento de cúspides (P=0,273); da mesma maneira não houve significância na interação entre ambos fatores (P=0,972). Houve grande porcentagem de fraturas catastróficas envolvendo espaço biológico, em todos os grupos. Os resultados de adaptação marginal mostraram diferença estatisticamente significante entre os grupos (P=0,005), sendo que os melhores valores foram apresentados pelo grupo G3, e os piores pelo grupo G2. Para adaptação marginal, verificou-se a existência de diferença estatisticamente significante para o fator abertura de caixa oclusal (P=0,001), sendo que a abertura extensa apresentou melhores valores do que a conservadora; entretanto, não houve diferença significante com relação ao fator recobrimento de cúspide (P=0,425). A interação entre ambos os fatores não apresentou diferença estatisticamente significante (P=0,301). O teste de correlação de Pearson demonstrou significância somente para o grupo G7. A ausência de diferenças na resistência à fratura entre os grupos preparados e os padrões de fratura demonstra a capacidade de formação de corpo único entre restauração e dente, levando à conclusão da ausência de necessidade de recobrimento de cúspide nos tipos de preparo confeccionados neste estudo. A melhor adaptação marginal dos grupos com abertura extensa remete à menor necessidade de ajustes internos das peças, fator que possivelmente gerou pior adaptação nos grupos de abertura conservadora. / Mestre em Odontologia
44

Avaliação de dois diferentes planejamentos de próteses totais fixas implantossuportadas, comparando as técnicas de fabricação das infraestruturas: tecnologia CAD-CAM, fundição convencional e barra articulada / Evaluation of two different designs of full-arch implant-supported fixed dentures, comparing the infrastructure manufacturing techniques: CAD-CAM technology, conventional casting and Articulated Bar

Rafael Cândido Pedroso e Silva 27 January 2016 (has links)
O objetivo deste estudo foi avaliar dois diferentes planejamentos de próteses totais fixas implantossuportadas, comparando as técnicas de fabricação das infraestruturas: tecnologia CAD-CAM, fundição convencional e Barra Articulada. Após ciclagem termomecânica, foram analisadas a perda de torque dos parafusos protéticos e adaptação marginal vertical e horizontal. Ao final, as próteses foram submetidas a ensaios de fadiga acelerada progressiva e resistência à fratura. Foram confeccionadas 48 próteses totais fixas implantossuportadas, as quais foram divididas inicialmente em dois grupos, G1 protocolo convencional; G2 - &ldquo;All-on-4&rdquo;. De acordo com a técnica de fabricação das infraestruturas, estes grupos foram divididos em três subgrupos, A - tecnologia CAD-CAM; B - fundição convencional; C - Barra Articulada, proporcionando seis amostragens diferentes: G1A, G1B, G1C, G2A, G2B e G2C (n=8). Todas as próteses foram avaliadas em relação à adaptação marginal vertical e horizontal, utilizando MicroCT, antes e após a ciclagem termomecânica (2.000.000 de ciclos). A perda de torque dos parafusos protéticos foi analisada antes (T0), após 1.000.000 (T1) e 2.000.000 de ciclos (T2). Após este ensaio, as próteses foram submetidas ao teste de fadiga acelerada progressiva (n=8) e em sequência, ensaio de resistência à fratura (n=6). A perda de torque teve diferença significante para todos os tempos comparados (p<0,01), exceto em G2B, onde a comparação entre T1 - T2 não mostrou diferença significante (p=0,72). A comparação entre G1 e G2 não foi significante. A comparação entre os subgrupos A, B e C teve diferenças significantes em G1T1, G1T2, G2T1 e G2T2 quando comparados os subgrupos A - B e B - C, todos com (p<0,01). Não houve diferenças significantes para a adaptação marginal vertical e horizontal antes e depois da ciclagem em todos os grupos. Na comparação de G1 e G2, houve diferença significante para a adaptação vertical e horizontal apenas no subgrupo B, nos dois tempos, ambos com (p <0,01). Na comparação dos subgrupos A, B e C, houve diferenças significantes em G1 antes e depois; e G2 antes e depois, quando comparados os subgrupos A - B e B - C, todos com (p<0,01) para a adaptação vertical e horizontal. Já para a adaptação horizontal, esta comparação foi significante apenas em G2 antes e depois, ambos com (p=0,02). Em relação à resistência à fratura, a comparação entre G1 e G2, foi significante em todos os subgrupos, A e C (p<0,01), B (p=0,02). A comparação dos subgrupos A, B e C, também foi significante em relação à resistência à fratura das próteses em todos os grupos (p<0,01). Pode-se concluir que a simulação de ciclos mastigatórios teve influência significante sobre a perda de torque dos parafusos protéticos, porém não influenciou significativamente a adaptação marginal vertical e horizontal das próteses; desadaptações marginais influenciaram significativamente no afrouxamento dos parafusos protéticos; as próteses dos subgrupos A e C obtiveram resultados significantemente melhores para a adaptação marginal vertical e horizontal quando comparadas às do subgrupo B, sendo que na adaptação horizontal, as do subgrupo A tiveram resultados melhores que as do C; a quantidade e distribuição dos implantes não influenciou na perda de torque dos parafusos protéticos em todas as situações, porém teve influência significativa na adaptação marginal vertical e horizontal das próteses do subgrupo B; todas as próteses sobreviveram ao ensaio de fadiga acelerada progressiva; em relação ao ensaio de resistência à fratura, as próteses do G2, tiveram resultados significantemente melhores que as do G1, o subgrupo B obteve valores significantemente maiores de resistência na região do cantilever, quando comparadas ao subgrupos A e C; o subgrupo A obteve os menores valores de resistência. / The objective of this study was evaluate two different designs of full-arch implant-supported fixed dentures, comparing the infrastructure manufacturing techniques: CAD-CAM technology, conventional casting and Articulated Bar. After thermomechanical cycling, were analyzed prosthetic screws loosening and vertical and horizontal marginal adaptation. In the end, the prostheses were submitted to tests of progressive accelerated fatigue and fracture resistance. Were made 48 implant-supported fixed dentures, which initially were divided into two groups, G1 - conventional protocol; G2 - \"All-on-4\". According to the technique of manufacturing infrastructure, these groups were divided into three subgroups: A - CAD-CAM technology; B - conventional casting; C - Articulated bar, providing six different samples: G1A, G1B, G1C, G2A, G2B e G2C (n=8). All samples were evaluated in the vertical and horizontal marginal adaptation using MicroCT before and after the thermomechanical cycling (2,000,000 cycles). The loosening of the prosthetic screws was analyzed before (T0), 1,000,000 (T1) and 2,000,000 cycles (T2). After this test, the prostheses were submitted to progressive accelerated fatigue test (n = 8) and sequentially fracture resistance test (n = 6). The prosthetic screw loosening has significant difference for all time compared (p <0.01), except in G2B where the comparison between T1 - T2 showed no significant difference (p = 0.72). The comparison between G1 and G2 was not significant. The comparison between subgroups A, B and C had significant differences in G1T1, G1T2, G2T1 and G2T2 compared subgroups A - B, B - C, all of (p <0.01). There were no significant differences for vertical and horizontal marginal adaptation before and after cycling in all groups. Compared to G1 and G2, there was a significant difference for vertical and horizontal adjustment only in the subgroup B in two stages, both (p <0.01). In the comparison of subgroups A, B and C, there were significant differences G1 before and after; and G2 before and after, when compared subgroups A - B, B - C, all of (p <0.01) for vertical and horizontal adaptation. As for the horizontal adaptation, this comparison was significant only in G2 before and after, with both (p = 0.02). With regard to fracture resistance, the comparison between G1 and G2 was significant in all subgroups, A and C (p <0.01), B (p = 0.02). The comparison of subgroups A, B and C was also significant compared to the fracture resistance of the prosthesis in all groups (p <0.01). It can be concluded that the simulation of mechanical cycling had significant influence on the loosening of prosthetic screws, but did not significantly influence the vertical and horizontal marginal fit of the prosthesis; marginal adaptation significantly influenced the loosening of prosthetic screws; the prostheses of the subgroups A and C had significantly better results for the vertical and horizontal marginal adaptation when compared to the subgroup B, and in the horizontal adaptation, the sub-group A had better results than those of C; the amount and distribution of the implants did not affect the prosthetic screws loosening in all situations, but had significantly influence in vertical and horizontal marginal adaptation of subgroup B prostheses; all samples survived in progressive accelerated fatigue test; in relation to the fracture resistance test, the prosthesis G2, had significantly better results than the G1, the B subgroup achieved significantly higher values of resistance in the cantilever region, when compared to subgroups A and C; the subgroup C obtained the smallest resistance.
45

Influência do bisel na resistência à fratura de dentes restaurados com resina composta / The influence of bevel in the fracture resistance of teeth with composite resin restorations

Fabiano Bassalobre Valera 16 October 2007 (has links)
Avaliou-se a resistência à fratura de dentes pré-molares, com e sem bisel no ângulo cavo-superficial, restaurados com resina composta. Noventa dentes prémolares superiores foram divididos em 9 grupos. O grupo 1, considerado controle positivo, constituiu-se de dentes hígidos. Os grupos de 2 a 9 receberam cavidades de Classe II MOD, com medidas padronizadas. Os grupos de 6 a 9, além das cavidades, tiveram os tetos das câmaras pulpares removidos. Para os grupos 2, 3, 6 e 7, o ângulo cavo-superficial apresentou-se nítido e sem bisel; grupos 4 e 8, bisel côncavo em toda cavidade; grupos 5 e 9, bisel apenas na porção oclusal da cavidade. Os dentes dos grupos 2 e 6 não foram restaurados, sendo considerados controle negativo. Para os demais grupos, procedeu-se a restauração das cavidades com sistema restaurador adesivo pela técnica direta. Todos os espécimes foram avaliados quanto a resistência à fratura, em uma maquina de teste universal (Emic - DL 2000), com célula de carga de 500Kgf, regulada a uma carga máxima de 450Kgf, com uma leitura mínima de 0,05Kgf de precisão. Os resultados foram submetidos à análise de variância a um critério e ao teste de Tukey para comparação entre os grupos. Constatou-se que houve diferença significante entre os grupos estudados, quando considerados os diferentes tratamentos do ângulo cavo-superficial (variável independente) e a resistência à fratura obtida (variável dependente) (p<0,05). A remoção de tecido dentário pela confecção de cavidades diminuiu a resistência à fratura do órgão dentário, sendo que em intervenções mais extensas, com a remoção de estrutura de reforço, como o teto da câmara pulpar, esta resistência se apresentou ainda menor. A confecção de bisel em todo o ângulo cavo-superficial, em cavidades de Classe II, proveu um aumento significante da resistência à fratura, quando comparado aos dentes que apresentaram o ângulo cavo-superficial nítido e sem bisel, tanto em dentes com ou sem remoção do teto da câmara pulpar. Além disso, dentes que apresentaram bisel em todo o ângulo cavo-superficial de cavidades de Classe II, tanto com ou sem intervenção endodôntica, mostraram os melhores padrões de fratura, preservando quase que em sua totalidade a integridade do remanescente dentário. / The fracture resistance of upper premolar teeth with and without cavosurface bevel, restored with composite resin material was evaluated. Ninety upper premolar teeth were divided into 9 groups. The group 1, considered as a positive control, was composed of sound teeth. Groups 2 to 9 receive Class II MOD preparation cavities with standardized measures. Groups from 6 to 9 had the roof of the pulp chamber removed. In groups 2, 3, 6, and 7, the cavosurface angle was evident and without bevel; groups 4 and 8, a concave bevel around the entire cavity; groups 5 and 9, the bevel was only placed in the oclusal portion of the cavity. Teeth in groups 2 and 6 were not restored, and considered as negative controls. In the other groups, cavities were directly restored with an adhesive resin system. All specimens were evaluated until load to fracture in a Universal Testing Machine (Emic DL 2000), with a load cell of 500Kgf, maximum load of 450Kgf, and 0,05kgf of standard error. Results were submitted to one-way analysis of variance and Tukey\'s test for group comparisons. There was a significant difference among the studied groups regarding the different treatments on the cavosurface angle (independent variable) and the fracture resistance (dependent variable) (p<0.05). Removal of tooth structure through cavity preparation diminished the fracture resistance values, being that in more extensive preparation (removal of the roof of pulp chamber), this value was lower. The bevel placed around the entire cavosurface angle in Class II cavities significantly increased the fracture resistance, when compared to teeth with a clear cavosurface angle but without bevel, either in teeth with or without removal of the roof of pulp chamber. Besides, teeth with bevel around the entire cavosurface angle with or without endodontic therapy showed the best fracture patterns, almost completely preserving tooth integrity.
46

Avaliação da resistência à fratura em coroas metalocerâmicas e ceramocerâmicas, utilizando infra-estruturas com e sem reforço / Fracture resistance of metal-ceramic and all-ceramic crowns made with and without reinforced coping design

Daniel Eduardo Bayardo-González 03 April 2007 (has links)
As restaurações metalocerâmicas apresentam relatos de sucesso clínico a longo prazo e as características de reforço (cinta lingual e poste proximal) das infra-estruturas metálicas parecem ser de grande importância para este sucesso. Estes reforços freqüentemente estão ausentes nas infraestruturas das restaurações ceramocerâmicas. O objetivo deste estudo foi testar a hipótese nula de que coroas confeccionadas com infra-estruturas cerâmicas com desenho com e sem reforço não resultam em valores de resistência à fratura diferentes de coroas com infra-estruturas metálicas confeccionadas com os mesmos desenhos. Para a realização deste trabalho foram fabricadas 40 coroas, dividas em quatro grupos (n=10): (1) coroas metalocerâmicas - infra-estrutura com reforço; (2) coroas metalocerâmicas - infra-estrutura sem reforço; (3) coroas ceramocerâmicas - infra-estrutura com reforço; e (4) coroas ceramocerâmicas - infra-estrutura sem reforço. Os corpos de prova foram cimentados com ionômero de vidro modificado por resina nos troquéis metálicos e submetidos à análise de resistência à fratura usando uma máquina de teste universal Kratos, a uma velocidade de 0,5 mm/min. Todos os corpos de prova foram mantidos sob pressão até a fratura. Os resultados de resistência à fratura (kgf) foram submetidos à análise de variância (ANOVA) a dois critérios e ao teste de Tukey. O nível de significância considerado em todas as análises foi de 5% (p<0,05). Os valores médios de resistência à fratura foram de 237,637 kgf para as coroas metalocerâmicas com infraestruturas com reforço, 171,738 kgf para as coroas metalocerâmicas com infraestruturas com reforço, 127,588 kgf para as coroas ceramocerâmicas com infra-estruturas com reforço e 93,914 kgf para as coroas ceramocerâmicas com infra-estruturas sem reforço, com diferença estatisticamente significante (p<0,05), entre os quatro grupos. As coroas metalocerâmicas com reforço (Grupo 1) apresentaram o maior valor de resistência à fratura e estatisticamente significante, entre todos os grupos. As coroas confeccionadas com infra-estruturas com reforço apresentaram maior resistência à fratura do que as confeccionadas sem reforço, tanto nas coroas metalocerâmicas como nas ceramocerâmicas. / Metal-ceramic restorations present reports of long-term clinical success, and the characteristics of reinforcement coping (lingual collar and buttressing shoulder) seem to be of great importance for this success. These reinforcements are often absent in all-ceramic coping restorations. The aim of the current study was to evaluate and compare the in vitro fracture resistance of metal-ceramic and In-Ceram Alumina all-ceramic crowns, with and without reinforced coping design. Forty crowns were fabricated and divided into four groups (n=10): group 1, metal-ceramic crown with reinforced coping design; group 2, metal-ceramic crown without reinforced coping design; group 3, allceramic crown with reinforced coping design and group 4, all-ceramic crown with out reinforced coping design. The forty crowns were cemented on stainless steel dies and axially loaded in a universal testing machine until fracture occurred, and the maximum load (kgf) was recorded. Data were analyzed by one-way analysis of variance (ANOVA) and Tukey test (p<0.05) The results showed a statistical significant superiority (p<0.05) of the reinforcement coping groups (237.637 kgf for metalo-ceramic crowns and 127.588 kgf for all-ceramic crowns), regarding to non reinforcement coping groups (171.738 kgf for metalo ceramic crowns and 93.914 kgf for all-ceramic crowns). These founds denote that: (1) crowns made with reinforcement coping had presented greater fracture resistance than those confectioned without it and (2) metal-ceramic crowns had presented greater fracture resistance than all-ceramic crowns.
47

Impacto da cavidade endodôntica conservativa no preparo e comportamento biomecânico de pré-molares superiores restaurados com diferentes materiais / Impact of the conservative endodontic cavity on the biomechanical preparation and behavior of maxillary premolars restored with different materials

Pereira, Rodrigo Dantas 16 May 2018 (has links)
A proposta deste estudo foi avaliar o impacto da cavidade endodôntica conservativa no preparo de canais radiculares com diferentes sistemas de instrumentação e no comportamento biomecânico de pré-molares superiores restaurados com diferentes materiais restauradores. Noventa pré-molares superiores com bifurcação radicular no terço cervical ou médio foram selecionados e escaneados em microtomógrafo para determinação de parâmetros bidimensionais (2D) e tridimensionais (3D) dos canais radiculares e dados de comprimento e volume de coroa e raiz. A partir desses dados, os espécimes foram distribuídos de acordo com a cavidade endodôntica de acesso: controle (hígido) (n=10), cavidade endodôntica convencional (CC) (n=40) e cavidade endodôntica conservativa (CEC) (n=40), e quanto ao sistema de instrumentação (n=10): Protaper Universal (PTU), Reciproc (RP), Reciproc Blue (RB) e Hiflex EDM (HEDM). As CC e CEC foram realizadas usando de brocas 1014 HL e Endo Z e inserto ultrassônico E7D e os espécimes foram escaneados para quantificar o tecido dental removido. Os dentes foram instrumentados com os sistemas PTU, RP, RB e HEDM seguindo as orientações dos fabricantes. Após o preparo biomecânico foi realizado novo escaneamento para avaliação das alterações dos parâmetros 2D e 3D dos canais radiculares e nova aleatorização quanto ao material restaurador (n=10): controle (material restaurador provisório), resina composta convencional, resina composta bulk fill regular e resina composta bulk fill fluida associada a resina composta convencional. Os espécimes foram obturados com cimento à base de resina epóxica e cone único e selados com cimento provisório. Após sete dias os dentes foram restaurados de acordo com seus respectivos grupos utilizando resina composta convencional por meio da técnica incremental, resina composta bulk fill regular em incremento único e incremento único de resina composta bulk fill fluida com camada de resina composta convencional. Novo escaneamento foi realizado para analisar o material restaurador e presença de espaços vazios, seguido de inclusão para simulação do ligamento periodontal e ensaio de resistência à fratura e determinação do padrão de fratura. Foram gerados modelos tridimensionais das condições de acesso endodôntico e material restaurador para análise pelo método de elementos finitos. Os dados de preparo e comportamento biomecânico foram submetidos ao teste de T pareado, ANOVA e teste Tukey e qui-quadrado (=0,05). As cavidades endodônticas de acesso e sistemas de instrumentação apresentaram valores estatisticamente semelhantes para dados 2D e 3D, no entanto, observou-se que a CC propiciou maior centralização do canal radicular quando comparada a CEC. Os sistemas RB e HEDM apresentaram maior centralização quando comparados ao sistema PTU. O sistema Protaper apresentou maior percentual de paredes não tocadas em CEC. Menor percentual de material restaurador foi observado em CEC (78,7%) comparado a CC (96,3%), sendo observado em CEC maior percentual de material obturador e espaços vazios. Os valores de resistência à fratura e padrão de falha foram estatisticamente semelhantes para o grupo controle e grupos experimentais. Os grupos avaliados apresentaram comportamento similar na análise de elementos finitos, com maior concentração de tensões na cúspide palatina comparada à cúspide vestibular e maiores tensões na região de sulco principal e cristas marginais. Pode-se concluir que a CEC impactou negativamente na centralização do preparo biomecânico, sendo que PTU promoveu maior desvio e percentual de paredes não tocadas. A cavidade endodôntica de acesso não alterou o comportamento biomecânico de pré-molares superiores, no entanto, CEC apresentaram material obturador remanescente após tratamento endodôntico e maior percentual de espaços vazios no material obturador / The purpose of this study was to evaluate the impact of the conservative endodontic cavity in the biomechanical preparation with different systems and in the biomechanical behavior of maxillary premolars restored with different restorative materials. Ninety maxillary premolars with root bifurcation in the cervical or middle third were selected and scanned in microcomputed tomography for the determination of two-dimensional (2D) and three-dimensional (3D) parameters of root canals and length and volume data of the root and crown. From these data, the specimens were distributed according to the endodontic access cavity: control (higid) (n=10), conventional endodontic cavity (CC) (n=40) and conservative endodontic cavity (CEC) (n=40); and according the biomechanical preparation system (n=10): Protaper Universal (PTU), Reciproc (RP), Reciproc Blue (RB) and Hiflex EDM (HEDM). CC and CEC were performed using 1014 HL and Endo Z drills and E7D ultrasonic insert, followed by a new micro tomographic examination to quantify the removed dental tissue. The teeth were prepared with the PTU, RP, RB and HEDM systems following the manufacturers\' guidelines. After the biomechanical preparation, a new scanning was performed to evaluate the 2D and 3D root canal parameters changes and a new randomization was performed for the restorative material (n=10): control (temporary restorative material), conventional composite resin, bulk fill regular composite resin and resin composite bulk fill flow associated with conventional composite resin. The specimens were filled with epoxy resin-based sealer and single cone, and sealed with temporary restorative cement. After seven days the teeth were restored according to their respective groups with conventional composite resin using the incremental technique, composite resin bulk fill regular using a single increment and single increment of composite resin bulk fill flow with conventional composite resin layer. New scanning was performed to analyze the restorative material and presence of voids, followed by the inclusion for periodontal ligament simulation and fracture strength test and determination of fracture pattern. Three-dimensional models of endodontic access conditions and restorative material were generated for finite element analysis. The biomechanical preparation and biomechanical behavior data were submitted to paired T test, ANOVA and Tukey test and chi-square test (=0.05). The endodontic access cavities and biomechanical preparation systems presented statistically similar values for 2D and 3D data, however, it was observed that CC showed a greater centralization of the root canal compared to CEC. The RB and HEDM systems presented greater centralization compared to the PTU system. The Protaper system presented a higher percentage of untouched walls in CEC. A lower percentage of restorative material was observed in CEC (78.7%) compared to CC (96.3%), showing the presence of filling material and greater percentage of empty spaces in CEC. The values of fracture strength and failure pattern were statistically similar for the control group and experimental groups. The evaluated groups presented similar behavior in finite element analysis, with a higher stress concentration in the palatal cusp compared to the vestibular cusp and higher stress in the main sulcus region and marginal ridges. It can be concluded that the CEC had a negative impact on the centralization of the biomechanical preparation, and that PTU promoted greater deviation and percentage of untouched walls. The endodontic access cavity did not alter the biomechanical behavior of maxillary premolars, however, CEC had remaining filling material after endodontic treatment and greater percentage of voids
48

Avaliação da adaptação marginal e interna, da resistência à fratura após ciclagem termomecânica e das tensões nos implantes por correlação de imagens digitais em próteses parciais fixas sobre implantes com pilares e copings em zircônia com diferentes sistemas CAD/CAM / Evaluation of the marginal and internal fit, resistance to fracture after thermomechanical cycling and tensions in the implants by correlation of digital images in fixed partial dentures on implants with abutments and copings in zirconia with different CAD/CAM systems

Mendes, Francielle Alves 02 June 2015 (has links)
Considerando a crescente exigência estética, o desenvolvimento da zircônia e o incremento da tecnologia CAD/CAM o objetivo deste trabalho foi avaliar a adaptação marginal e interna, as tensões nos implantes e a resistência à fratura após prensagem da porcelana e termociclagem mecânica em próteses parciais fixas sobre implantes com pilares e infraestrutura em zircônia com dois sistemas CAD/CAM (Neodent digital - Neodent e Lava - 3M ESPE) comparados com o método convencional (n=10). A adaptação marginal e interna foi analisada por meio de um microtomógrafo computadorizado (microCT). Cada prótese foi digitalizada e os arquivos foram processadas utilizando o software NRecon e CTAN. Foi utilizado o programa Dataview para aferição das medidas. Para a realização da ciclagem termomecânica as próteses foram posicionadas na máquina de fadiga mecânica por mastigação e foi aplicada a carga de 120 N com uma ponta que simula a oclusão antagonista simulando 2.000.000 ciclos. Durante o ensaio, as próteses foram mantidas em água destilada e termocicladas com variação de temperatura entre 5º-55º C. Para a verificação das tensões geradas pelas próteses parciais fixas em torno dos implantes foi realizada a análise por correlação de imagens digitais. Foram selecionados cinco modelos de cada um dos sistemas CAD/CAM e um antagonista e aplicada uma carga de 250 N, com velocidade de 0,1 mm/min, em máquina universal de ensaios. Para avaliação da resistência à fratura foi aplicada uma força perpendicular ao longo eixo da peça protética, no pôntico, até que devido à fratura não houvesse mais resistência. Após esse teste foi avaliado o relacionamento entre os componentes da prótese em microscópio eletrônico de varredura (MEV). A análise estatística mostrou que houve diferença significativa na adaptação pilar-implante dos molares entre os grupos Lava e ZirNeo, Lava e Controle (p=0,008). Para a desadaptação vertical e horizontal antes e após a prensagem e ciclagem não houve diferença significante (p>0,005). A desadaptação interna axial mostrou diferença significante antes e após para os molares dos grupos Lava e ZirNeo (p<0,001). A desadaptação interna oclusal mostrou diferença significante para os PM dos grupos TiNeo e Controle e para os molares dos grupos Lava e Zir Neo (p<0,005). Houve diferença significante de tensão na região cervical dos molares dos grupos ZirNeo e Lava (p=0,015) com maiores valores de tensão para o grupo Lava. O grupo TiNeo teve maior resistência à fratura que os demais (p=0,022). O relacionamento entre os componentes da prótese permaneceu favorável para todos os grupos. Os resultados deste trabalho permitem concluir que a prensagem da porcelana e a termociclagem mecânica não influenciou os resultados da desadaptação marginal e melhorou a desadaptação interna. O grupo usinado pelo sistema Neodent digital em zircônia teve maior concentração de tensão na região cervical podendo ter maior perda óssea nessa região. O grupo TiNeo foi o que mais resistiu à fratura. Entre fresar em zircônia pelo sistema Neodent digital ou Lava, o sistema Lava distribui melhor a tensão ao longo do implante, porém teve maiores valores de desadaptação interna. Entre fresar em titânio ou confeccionar a prótese pelo sistema convencional, melhor fresar. / Considering the growing aesthetic requirements, the development of zirconia and the increase of CAD/CAM technology, the aim of this study was to evaluate the marginal and internal fit, tensions in implants and fracture resistance after pressing porcelain and thermomechanical cycling in FPDs on implants with abutments and infrastructure in zirconia with two CAD/CAM systems (Neodent digital -Neodent and Lava - 3M ESPE) compared with the conventional method (n = 10). The marginal and internal fit was analyzed by a computerized microtomograph (microCT). Each prosthesis was scanned and the files were processed using the NRecon and CTAN software. Dataview program was used for the assessment of the measures. To carry out the thermomechanical cycling, prostheses were placed in mechanical fatigue machine for chewing and 120 N load was applied with a tip that simulates the antagonist occlusion simulating 2,000,000 cycles. During the test, the prostheses were kept in distilled water and thermocycled with temperatures between 5°-55° C. Digital image correlation analysis was performed to check the load transfer by implant-supported restoration. Five models were selected from each of the CAD/CAM systems and an antagonist and a load of 250 N was applied, with 0.1 mm/min speed using a universal testing machine. The fracture resistance was verified with force applied perpendicular to the long axis of the prosthesis, at pontic, until there were no more fracture resistance. After this test was evaluated the relationship between the components of the prosthesis in a scanning electron microscope (SEM). The statistical analysis showed significant difference in abutment-implant fit of molars between Lava and ZirNeo, Lava and control groups (p=.008). For vertical and horizontal fit there was no significant difference (p>.005) before and after pressing and thermomechanical cycling. The axial internal gap was significantly different before and after for molar ZirNeo groups (p<.001). The occlusal internal fit was significantly different to the PM of TiNeo and Control, and the molars of Lava and ZirNeo (p<.005). There were significant difference for tension in the cervical region of the molars of ZirNeo and Lava (p=.015) with higher values for the Lava group. TiNeo group had higher resistance to fracture than others (p=.022). The relationship between the prosthesis components remained positive for all groups. The results of this study showed that the pressing of porcelain and thermomechanical cycling did not influence the results of marginal gap and improved internal fit. The zirconia group machined by Neodent digital system had higher concentration of tension in the cervical and may have greater bone loss in this region. TiNeo group was the most resistant to fracture. Between the zirconia milling by Neodent digital or Lava system, the Lava system distributes better strain throughout the implant, but had greater internal fit values. Between milling titanium or fabricate the prosthesis by the conventional system, better milling.
49

INFLUÊNCIA DA ADAPTAÇÃO DE PINOS DE FIBRA E DE TÉCNICAS RESTAURADORAS ALTERNATIVAS PARA PREENCHIMENTO DE CANAIS RADICULARES EXCESSIVAMENTE ALARGADOS / Influence of fiber posts adaptation and alternative restorative techniques for flared root canal filling

Gomes, Giovana Mongruel 20 September 2013 (has links)
Made available in DSpace on 2017-07-24T19:22:29Z (GMT). No. of bitstreams: 1 Giovana Mongruel Gomes.pdf: 3752517 bytes, checksum: 6acad02e468853d81d1d9172fd003844 (MD5) Previous issue date: 2013-09-20 / The objectives of this study were 1) to evaluate the effect of the influence of the resin cement thickness (RCT) on bond strength (BS) and gap formation (GF) between glass fiber post (FP) and root dentin and 2) to evaluate the BS and fracture resistance (FR) of restorative techniques for filling oversized root canals. In experiment 1, the roots of 24 mandibular premolars (n=8 per group) were endodontically treated. After one week, the post spaces were prepared depending on the post adaptation inside the root canal, simulating an ideal adaptation (IdAd),medium adaptation (MeAd) and inadequate adaptation (InAd). All posts were cemented with Excite® DSC and Variolink® II. After a week of cementation, the RCT and GF were measured with the Image Tool software version 3.0, and the BS by the push-out test. In experiment 2, the roots of 84 mandibular premolars were endodontically treated and, after a week, the conduits were prepared in order to simulate an oversized root canal, except for the positive control group (PC), which was cemented one prefabricated fiber post (PFP) with the diameter compatible with the conduit. In the other oversized root canals, alternative restorative techniques for filling root canals were tested: NC - negative control (PFP with a smaller diameter than of the root canal), PA - PFP + accessory posts, DAP – direct anatomical post,IAP – indirect anatomical post and RR – root reinforcement with composite resin. All posts were cemented with the same adhesive system and resin cement. After indirect composite crowns cementation, the teeth were submitted to mechanical fatigue (1.2 X 106 cycles, 40 N) before the push-out BS test (n=8) and the FR test (n=6). The data of experiments 1 and 2 were analyzed by ANOVA and paired test (α=0.05). The experiment 1 showed that the smaller RCT resulted in better fiber post adhesion, that is, higher BS and lower GF. The experiment 2 showed that the use of direct and indirect anatomical posts resulted in the best performance both in BS and FR tests,and must be the first choice for FP cementation in flared roots with oversized root canals. Therefore, we concluded that the post adaptation to root canal affected significantly its retention. The better the post adaptation, the better the laboratory results. However, in the absence of this ideal condition, the use of direct and indirect anatomic posts should be the first choice for restoring flared root canals. / Os objetivos deste estudo foram 1) avaliar o efeito da influência da espessura de cimento resinoso (ECR) na resistência de união (RU) e na formação de gaps (FG) entre pino de fibra de vidro (PFV) e dentina radicular e 2) avaliar a RU e resistência à fratura (RF) de técnicas restauradoras para preenchimento de canais radiculares excessivamente alargados. No experimento 1, as raízes de 24 pré-molares inferiores (n=8 por grupo) foram tratadas endodonticamente. Após uma semana, os condutos foram preparados em função da adaptação do pino no canal radicular, simulando uma adaptação ideal (AdId), média (AdMe) e inadequada (AdIn). Todos os pinos foram cimentados com Excite® DSC e Variolink® II. Uma semana após a cimentação, a ECR e a FG foram mensuradas com o software Image Tool versão 3.0 e a RU por meio do teste de push-out. No experimento 2, as raízes de 84 pré-molares inferiores foram tratadas endodonticamente e, após uma semana, realizou-se o preparo dos condutos, de maneira a simular um canal radicular excessivamente alargado, com exceção do grupo controle positivo (GCP), em que foi cimentado um pino préfabricado (PPF) com calibre compatível ao diâmetro do conduto. Nos outros condutos alargados, técnicas restauradoras alternativas de preenchimento dos canais radiculares foram empregadas: GCN – grupo controle negativo (PPF de diâmetro inferior ao conduto), GPA – PPF + pinos acessórios, GAD – pino anatômico direto, GAI – pino anatômico indireto e GRR – reforço radicular com resina composta + PPF. Todos os pinos foram cimentados com o mesmo sistema adesivo e cimento resinoso. Após cimentação de coroas de resina indireta, os dentes foram submetidos à fadiga mecânica (1,2 x 106 ciclos, 40 N) antes de realizar o teste de RU (n=8) e de RF (n=6). Os dados do experimento 1 e 2 foram analisados por ANOVA e teste pareado (α=0,05). O experimento 1 mostrou que quanto menor a ECR melhor a adesão dos PFV, ou seja, maior a RU e menor a FG. O experimento 2 mostrou que o uso de pinos anatômicos diretos e indiretos mostrou o melhor desempenho nos testes de RU e RF, e deve ser primeira opção para cimentação de PFV em canais radiculares alargados. Portanto, foi evidenciado que a adaptação do pino ao conduto radicular influenciou significativamente na retenção dos mesmos; quanto mais justa,melhores resultados laboratoriais. Entretanto, na ausência desta condição ideal, o uso de pinos anatômicos diretos e indiretos pode ser a primeira escolha do clínico para tratamento de canais excessivamente alargados. Palavras-chave: cimentos resinosos, dentina radicular, gap, microscopia eletrônica de varredura, pinos de fibra, raízes enfraquecidas, resistência à fratura, resistência de união.
50

Efeito da configuração do preparo cavitário e da composição cerâmica na distribuição de tensão, deformação e resistência à fratura de onlays confeccionadas por meio de CAD/CAM

Vianna, Ana Luíza Serralha de Velloso 21 February 2014 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / The aim of this study was to evaluate the effect of two cavity preparation on fracture resistande of two CAD/CAM ceramic on Finite Element Analysis, Coronal deformation, Fracture Resistance and Fracture Mode over human molar teeth restored with esthetic indirect restoration. Forty-eight human molars were select and randomly divided into the following four groups (n=12): Group 1: conventional onlay (with occlusal and proximal box), leucite glass ceramic (IPS-Empress CAD, Ivoclar Vivadent); group 2: conservative onaly (without occlusal and proximal box), leucite glass ceramic (IPS-Empress CAD, Ivoclar Vivadent); group 3: convencional onlay, lithium-disilicate glass ceramic (IPS e.max CAD, Ivoclar Vivadent); group 4: conservative onlay, lithium-disilicate glass ceramic (IPS e.max CAD, Ivoclar Vivadent). Cuspal deformation (&#956;S) was measured at 100N and Maximum fracture load by strain gauges (n = 7 teeth), Fracture Resistance (N) was measured by axial compression test and Fracture mode were recorded based on the degree of tooth structure and restoration damagemin four types (n = 12 teeth) and the Stress distributions was mesasure for all groups on Finite Element Analysis. The CS, Fracture resistance and Fracture mode were statistically analyzed using Tukey test and ANOVA two-way (p = 0.05). The Coronal deformation (CD) at 100N the Tukey s test showed that leucite ceramic restorations had significantly higher deformation than lithium-disilicate ceramic restorations, irrespective of cavity preparation (P<0.001). At maximum fracture load showed that lithium-disilicate ceramic restorations had significantly higher deformation than leucite ceramic restorations, irrespective of cavity preparation (P<0.001). The Fracture resistance and Fracture mode showed that the presence of box had no significant effect for leucite ceramic restoration (P=0.375), however the presences of box on disilicate ceramic restorations reduced significantly the fracture resistance (P<0.001). The disilicate ceramic restorations had significantly higher fracture resistance than leucite ceramic restoration (P <0.001) irrespective of cavity preparation. Fracture mode distributions showed that the leucite disilicate ceramic resulted in more severe fracture mode irrespective of cavity preparation. Whithin the limitations of this study, it was observed that the conservative onlay increase fracture resistence and the complex restored with a leucite-reinforced ceramics has less coronal deformation and fracture mode. / O objetivo deste estudo foi avaliar o efeito da morfologia do preparo cavitário na distribuição de tensões, comportamento biomecânico e resistência à fratura de molares restaurados indiretamente por dois sistemas cerâmicos. Quarenta e oito terceiros molares inferiores hígidos e com formas semelhantes extraídos foram divididos em 4 grupos (n=12) resultantes da combinação de dois fatores em estudo: 1- tipo de sistema cerâmico: Leucita (IPS-Empress CAD, Ivoclar Vivadent Ltda) e Dissilicato de Lítio (IPS e.max CAD, Ivoclar Vivadent Ltda); 2- Protocolo restaurador: onlay convencional e onlay conservador. A deformação coronal (&#956;S) na carga de 100N e carga máxima a fratura foi medida por strain gauges (n= 7). A resistência à fratura (N) foi medida pelo teste de compressão axial e o modo de falha foi avaliado de acordo a destruição da estrutura dental e restauração em quatro tipos (n=12) e a distribuição de tensões foram analisadas em quatro grupos pelo método de análise de Elementos Finitos. A deformação coronal (DC), resistência à fratura (RF) e modo de falha (MF), foram analisados estatisticamente usando análise de variância ANOVA two-way e Teste de Tukey (p&#706;0,05). A análise de variância ANOVA two-way mostrou que a DC, em uma carga de 100N, apenas o fator restauração cerâmica (p<0,001) teve efeito significativo, na qual a cerâmica reforçada por leucita teve significantemente maior deformação que a cerâmica reforçada por dissilicato de lítio (p<0,001). Além disso, os preparos feitos com caixas proximal e oclusal resultaram em uma deformação similar do preparo sem as caixas (p<0,001). Na carga máxima à fratura apenas o fator tipo de cerâmica (p<0,001) tiveram efeito significativo no teste de RF, na qual as restaurações de dissilicato de lítio tiveram maior deformação que a leucita (p<0,001). Os testes de RF, mostraram que a presença das caixas não teve efeito significativo nas cerâmicas reforçadas por leucita (p=0,375), enquanto que a presença das caixas proximais e oclusais nas restaurações de cerâmica reforçada por dissilicato de lítio tiveram diminuição significativa na RF (p<0,001). As cerâmicas de dissilicato de lítio tiveram significantemente maior RF do que as cerâmicas de leucita (p<0,001). E no MF, a restaurações de dissilicato de lítio resultaram em fraturas mais catastróficas independente da geometria do preparo cavitário. De acordo com as limitações deste estudo in vitro e computacional, foi observado que o preparo mais conservador aumenta a resistência à fratura e o complexo restaurador com cerâmica reforçada por leucita teve menor deformação coronal e menor modo de falha. / Mestre em Odontologia

Page generated in 0.0839 seconds