• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 410
  • 23
  • 23
  • 23
  • 23
  • 16
  • 7
  • 3
  • 3
  • 3
  • 3
  • 3
  • 1
  • Tagged with
  • 418
  • 418
  • 154
  • 108
  • 99
  • 92
  • 73
  • 50
  • 49
  • 45
  • 40
  • 40
  • 39
  • 36
  • 36
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
251

Resistência de união à dentina de um sistema adesivo de frasco único: avaliação em 24 horas e seis meses de armazenamento

Manfroi, Fernanda Borguetti January 2014 (has links)
Made available in DSpace on 2014-07-04T02:02:33Z (GMT). No. of bitstreams: 1 000459061-Texto+Completo-0.pdf: 2282963 bytes, checksum: c9b1fec421065d44d34540a0b1217b0a (MD5) Previous issue date: 2014 / The aim of this study was to evaluate the bond strength of Scotchbond Universal to dentin in both total-etch and self-etch applications after storage in water for 24 h and 6 months. The occlusal surface of 24 third molars was removed to obtain flat dentin surfaces, and the teeth were divided into four groups (n=6/grupo): G1 – total-etch application of Scotchbond Universal; G2 – self-etch application of Scotchbond Universal; G3 – Scotchbond Multi Purpose (total-etch application control); G4 – Clearfil SE Bond (self-etch application control). Following the adhesive application, a 6 mm height block of composite resin Z250 was built on the adhesive area. After storage in distilled water at 37ºC for 24 hours, the tooth/resin sets were cut parallel to the long axis of the tooth, in the x and y directions, with a section of about 0. 8 mm2. Forty specimens were obtained for each group; 20 specimens were immediately submitted to microtensile bond strength test, and the others after storage in distilled water at 37o C for 6 months. The microtensile bond strength test was performed in an universal testing machine (EMIC-DL 2000) at 0. 5 mm/min crosshead speed. The failures were observed in scanning electron microscopy (SEM). Additionally, two sets of each group were sectioned mesio-distal in the center of their crown with a diamond blade. The surfaces were polished by wet sanding with 400, 600 and 1200-grit silicon carbide abrasive paper, followed by polishing with 6, 3, 1 and ¼ m diamond paste.The samples were demineralized, deproteinized, dried, metalized and observed on a scanning electron microscope at 1. 500x. The bond strength means (MPa) obtained were the following: 24 h – G1 (39. 37); G2 (31. 02); G3 (35. 09); G4 (35. 84); 6 months – G1 (36. 99); G2 (40. 58); G3 (32. 44); G4 (41. 75). According to two-way ANOVA, there was no significance for adhesive system (p=0,110) and storage time (0,108), but the interaction of adhesive system and storage time was significant (p=0. 015). At 24 h, there was no statistical difference in bond strength between the adhesive systems (p>0,05). At 6 months, there was statistical difference between the adhesive systems (p<0. 05). Clearfil SE Bond obtained the higher bond strength mean, not differing statistically from self-etch application of Scotchbond Universal. Total-etch application of Scotchbond Universal did not differ statistically from Scotchbond Multi Purpose. Most of failures were mixed in both periods of evaluation.The SEM images of the adhesive interface of Scotchbond Universal total-etch application and Scotchbond Multi Purpose showed thicker hybrid layers and more resin tags in comparison with Scotchbond Universal self-etch application and Clearfil SE Bond. It was concluded that the simplification of Scotchbond Universal in one bottle did not decrease the bond strength of this adhesive to dentin during 6 months of storage. / O objetivo do estudo foi avaliar a resistência de união à dentina do sistema adesivo Scotchbond Universal na versão total-etch e self-etch em 24 horas e 6 meses de armazenamento. A superfície oclusal de 24 dentes terceiros molares hígidos foi removida para obter superfície plana em dentina, sendo divididos aleatoriamente em quatro grupos (n=6/grupo): G1 - Scotchbond Universal na versão total-etch; G2 – Scotchbond Universal na versão self-etch; G3 – Scotchbond Multi Purpose (controle da versão total-etch); G4 – Clearfil SE Bond (controle da versão self-etch). Sobre o sistema adesivo foi confeccionado um bloco de 6 mm de altura em resina composta Z250. Após 24 horas de armazenagem em água destilada a 37º C, os conjuntos dente/resina foram cortados paralelamente no longo eixo do dente, nos sentidos x e y, com secção de aproximadamente 0,8 mm2. Quarenta corpos de prova foram obtidos para cada grupo, sendo 20 submetidos imediatamente ao teste de resistência à microtração e, os outros 20, após 6 meses de armazenamento em água destilada a 37º C. O ensaio de microtração foi realizado em uma máquina de ensaio universal EMIC DL-2000, com uma velocidade de 0,5 mm/min. Os tipos de falha foram observados em microscopia eletrônica de varredura (MEV).Adicionalmente, dois conjuntos dente/resina foram preparados e seccionados no sentido mésio-distal, no centro de suas coroas, com um disco diamantado de dupla face. As superfícies foram polidas com lixas de carbeto de silício 400, 600 e 1200, seguido de polimento com pastas diamantadas de granulação 6, 3, 1 e ¼ m. As amostras foram desmineralizadas, desproteinizadas, secadas, metalizadas e observadas em MEV em aumento de 1. 500 vezes. No teste de microtração as médias obtidas (MPa) foram as seguintes: 24 h – G1 (39,37); G2 (31,02); G3 (35,09); G4 (35,84); 6 meses – G1 (36,99); G2 (40,58); G3 (32,44); G4 (41,75). De acordo com o teste ANOVA de duas vias não houve significância para o sistema adesivo (p=0,110) e para o tempo (0,108), mas apenas para a interação entre sistema adesivo e tempo (p=0,015). No período de 24 horas, não houve diferença estatística significativa na resistência à microtração entre os sistemas adesivos (p>0,05). Na avaliação de seis meses de armazenamento, houve diferença estatística entre os sistemas adesivos (p<0,05). O Clearfil SE Bond apresentou o maior valor médio de resistência à microtração, não diferindo estatisticamente do Scotchbond Universal self-etch e total-etch. O Scotchbond Universal total-etch não diferiu estatisticamente do Scotchbond Multi Purpose.Os tipos de falha foram predominantemente mistas para os dois períodos de avaliação. A interface adesiva do Scotchbond Universal na versão total-etch e o Scotchbond Multi Purpose apresentaram camada híbrida mais espessa e mais tags de resina em comparação ao Scotchbond Universal na versão self-etch e Clearfil SE Bond. Concluiu-se que a simplificação em frasco único do Scotchbond Universal não causou diminuição nos valores de resistência de união deste material à dentina em até 6 meses de avaliação.
252

Compósitos poliméricos para imageamento óptico e por raios-x em tanques de simulação hidráulica

Reis, Maria Helena da Silva January 2014 (has links)
Made available in DSpace on 2014-08-20T02:02:10Z (GMT). No. of bitstreams: 1 000459626-Texto+Parcial-0.pdf: 120396 bytes, checksum: a65ae75d299912b9f56c5f620ace594e (MD5) Previous issue date: 2014 / This research is related to the investigation of new approaches for noninvasive imaging that allow registering the internal architecture of sedimentary deposits generated in hydraulic simulation tanks. The simulations are conducted to better understand the behavior of turbiditic currents, one of the principal process responsible for the deposition of sediments in deep oceanic waters. For this reason it is purpose of this work the preparation of polymer nanocomposite with inorganic filler for non-destructive testing, with properties and characteristics similar to Coal 205, material currently used in these simulations. As polimeric matrix it was used an orthophthalic polyester resin prepared by mass polymerization, with dyes in different colors and inserting inorganic filler at different concentrations. Barium sulfate was used as the inorganic filler. Using the X-ray tomography tests, it was observed that barium sulfate provides the opacity needed for detection technique and shows potential to be used in non-invasive imaging at the simulations. Through scanning electron microscopy (SEM) it was possible to assess the prepared polymer matrix and classify it as semi-angular and semi-rounded shape. Also was observed at the SEM micrographs that the barium sulfate prepared it was in nanometer dimension. The prepared composites presented specific weight and settling velocity speed values similar to Coal 205 and it was observed that the incorporation of the filler and the different dyes did not affected significantly the desired characteristics. / Este trabalho de pesquisa está relacionado com a investigação de novas abordagens de imageamento não-invasivo que permitam registrar a arquitetura interna de depósitos sedimentares gerados em tanques de simulação hidráulica. Estas simulações são realizadas para melhor compreensão do comportamento das correntes de densidade, que constituem uma das principais responsáveis pela deposição de sedimentos em águas oceânicas profundas. Para isto foi proposta deste trabalho o preparo de nanocompósito polimérico com carga inorgânica para ensaios não destrutivos, com as propriedades e características semelhantes ao Carvão 205, material atualmente utilizado nas simulações. Como matriz polimérica foi utilizada a resina poliéster, preparada por polimerização em massa, com corantes de diferentes cores e inserção de carga inorgânica em diferentes concentrações. Como carga inorgânica foi utilizado o sulfato de bário. Por ensaios de tomografia de raios-X, observou-se que o sulfato de bário disperso na matriz de resina poliéster oferece a opacidade necessária para detecção pela técnica e se mostra potencial para uso nas simulações e imageamento não-invasivo. Por meio de microscopia eletrônica de varredura (MEV) foi possível avaliar a forma da matriz polimérica preparada e classifica-la com forma semi-angular e semi-arredondada. Também foi possível observar nas micrografias obtidas por MEV que a carga de sulfato de bário preparada apresentou dimensões nanométricas. Os compósitos preparados apresentaram valores de peso específico e velocidade de queda comparáveis com os do Carvão 205 e observou-se que a incorporação de corante e carga não influencia significativamente as características desejadas. Desta forma, os compósitos preparados se mostram com potencial para uso nas simulações de correntes de densidade não conservativas.
253

Vitrocerâmicas de alta resistência mecânica obtidas a partir da cristalização do sistema SiO2-Al2O3-MgO-Li2O com adição de ZrO2 e B2O3 /

Souza Filho, Manoel Pereira de, 1952- January 2013 (has links)
Orientador: Elson de Campos / Coorientador: Francisco Cristóvão Lourenço de Melo / Banca: Rogério Pinto Mota / Banca: Antonio Jorge Abdalla / Banca: Luiz Antonio Genova / Banca: Francisco Piorino Neto / Resumo: Neste trabalho estudou-se as vitrocerâmicas obtidas a partir de vidro base do sistema SiO2-Al2O3-MgO-Li2O com adição de ZrO2, como agente nucleante e do B2O3, que tem a função de reduzir a viscosidade do sistema durante o processo de fusão. Os vidros precursores foram obtidos por fusão na temperatura de 1650 ºC, em cadinhos de mulita-zirconia. Os vidros fundidos foram vertidos em molde de grafite para obtenção das amostras monolíticas, e em água para obtenção do material particulado. Este material foi moído e passou por processo de prensagem uniaxial e isostática, antes da sinterização. Para produção das vitrocerâmicas foram realizados tratamentos térmicos em duas condições diferentes. Na primeira as amostras foram aquecidas até 1100 ºC, com taxa de 10 ºC/min, e, na segunda, aquecimento inicial até a temperatura de 780 ºC, com taxa de 10 ºC/min e, em seguida, aquecimento até 1100 ºC, com taxa de 1ºC/min. Sobre os vidros foram feitas análises de dureza indicando valores em torno de 7,0 GPa. Com relação às vitrocerâmicas, os maiores valores de dureza, em torno de 9,2 ± 0,5 GPa, foram verificados nas amostras monolíticas cristalizadas no volume e que estiveram sob tratamento térmico com duas taxas de aquecimento (10 ºC/min até 780 ºC e 1 ºC/min até 1100 ºC) / Abstract: This work presents the results of the study with glass-ceramics obtained from base glass of the MgO-Al2O3-SiO2-Li2O system with addition of ZrO2 as nucleating agent and B2O3, which has the function to reduce the viscosity of the system during the melting process. The parent glasses were obtained by fusing at the temperature of 1650 ºC in crucible zirconia-mullite. The molten glasses were poured into a graphite mold to obtain the monolithic samples and also in water in order to obtain particulate material. Such material was grinded and then pressed by the uniaxial and isostatic pressing method before being sintered. Both the monolithic and pressed samples were performed under two different conditions of heat treatment for their nucleation and crystallization. In the first one the samples were heated to 1100 ºC with a heating rate of 10 ºC/min In the second one there was an initial heating rate of 10 ºC/min until reaching 780 ºC. Such temperature was kept for 5 minutes. After that, the samples were heated to 1100 ºC at a rate of 1 ºC/min microhardness analysis showed that base glass presented values around 7.0 GPa. The glass-ceramics obtained from the sintering powder had microhardness values smaller than those obtained from the monolithic samples. The highest hardness values were obtained in samples that were treated (10 ºC/min to 780 ºC and 1 ºC/min to 1100 ºC) which reached values around 9.2 ± 0.5 GP / Doutor
254

Influência do dicromato de potássio no comportamento do cimento aluminoso visando ao processo de S/E de resíduos com cromo

Ivanov, Raphael Coelli 30 August 2013 (has links)
A quantidade de resíduos gerados em diversos segmentos industriais vem aumentando com o passar dos anos. Temas como a disposição final de resíduos e os riscos de poluição de sistemas biológicos onde esses são depositados, denotam-se como grandes problemáticas envolvidas nos avanços destes segmentos. Dentre as técnicas mais utilizadas de disposição final de resíduos, o processo de Solidificação/Estabilização (S/E) em matriz de cimento é apresentado como uma tecnologia de destaque para imobilização de materiais residuais contendo metais pesados. Neste estudo, os cimentos Aluminosos Fondu e Secar (51) e cimento Portland (ARI) foram empregados como materiais aglutinantes objetivando a imobilização do dicromato de potássio, o qual apresenta como principal constituinte o Cr no estado hexavalente. As variações ocorridas durante a hidratação dos cimentos frente à adição de dicromato de potássio foram investigadas utilizando técnicas de monitoramento da temperatura de hidratação e determinação das principais fases consumidas e formadas. Para isto difratometria de raios X, microscopia eletrônica de varredura e análises térmicas (diferenciais e termogravimétricas) foram utilizadas. Os resultados obtidos para esta etapa mostram que as adições de dicromato de potássio acarretaram em reduções no consumo das fases anidras, bem como, na formação das principais fases hidratadas para os três cimentos estudados, sendo a adição de 2,5% de cromo (VI) a responsável pelas maiores quedas. Para investigação da eficiência da retenção do cromo (total e hexavalente) e a avaliação da integridade estrutural dos produtos formados, técnicas de lixiviação e resistência mecânica foram empregadas. Como resultados, foram verificadas que as matrizes de cimento Aluminoso registraram os maiores valores de eficiência na retenção do cromo atingindo níveis superiores a 99%. Entretanto, o parâmetro resistência à compressão apresentou quedas de até 60% em relação às argamassas de referência com 0% de cromo. Já para o cimento Portland, a adição do sal de cromo não influenciou de maneira significativa nas resistências à compressão, entretanto a análise de retenção do metal indica a menor eficiência deste tipo de cimento, uma vez que as concentrações acima de 0,5% de cromo foram lixiviadas a níveis superiores ao estabelecidas pela norma. / The increasing amount of waste generated in several industries has been increasing over the years. Topics such as waste disposal and pollution risks of biological systems where these are deposited denote as main issues involved in advancing these sectors. Among the most widely used techniques of waste disposal process, Solidification / Stabilization (S / E) in the cement matrix are a prominent technology for immobilization of waste materials containing heavy metals. In this study, the aluminous cement (Fondu and Secar 51) and Portland cement (ARI) were used as binder materials aimed at immobilizing the potassium dichromate, which has as its main constituent Cr in the hexavalent state. The variations during hydration of cements before the addition of potassium dichromate were investigated using techniques of hydration heat monitoring and determination of the main phases formed and consumed. For this purpose, X-ray diffraction, scanning electron microscopy and thermal gravimetric analysis and differential thermal analysis were used. The results show that for this step adding of potassium dichromate resulted in reductions in the consumption of anhydrous phases, as well as the formation of the main hydrated phases for the three cements studied, being the addition of 2.5% of chromium (VI) responsible for the biggest decay. To investigate the efficiency of retention of chromium (hexavalent and total) and the evaluation of the structural integrity of the products formed, leaching techniques and mechanical strength were used. As results, the aluminous cement matrices showed the highest values of efficiency in retaining chrome, achieving more than 99%. However, the compressive strength parameter showed declines of up to 60% compared to the references folders with 0% chromium. As for the Portland, adding the chromium salt did not have a significantly influence in the compressive strength, however, the metal retention analysis indicates the ineffectiveness of this type of cement, since the concentrations above 0.5% chromium were leached to levels above the established norm.
255

Proposta de método de ensaio para determinação da resistência ao cisalhamento paralelo às fibras de madeiras mediante esforço induzido por puncionamento do corpo de prova

Hara, Massayuki Mario 22 August 2011 (has links)
Esta pesquisa tem por objetivo analisar os procedimentos e os resultados de métodos de ensaios propostos para a identificação da resistência ao cisalhamento de madeiras no sentido paralelo as fibras. Almeja-se observar as imperfeições dos métodos existentes, com intuito de propor um novo método de ensaio em que algum dos problemas apresentados possam ser minimizados ou reduzidos. O método proposto pela norma NBR 7190/97 utiliza um corpo de prova prismático retangular com um dente para impedir sua rotação, causada pela assimetria na aplicação da força que promove o cisalhamento. O método proposto por SANTOS NETO (1999) utiliza também um corpo de provas prismático longelíneo com interrupções parciais alternadas nas seções transversais, as quais promovem solicitações de cisalhamento em regiões pré-escolhidas. Como alternativa, o presente estudo apresenta dois métodos: o primeiro método de ensaio sugerido é análogo ao ensaio da norma, porém aplicando a carga simetricamente a duas seções cisalhantes, de modo a evitar a rotação do corpo. Esse método evidenciou problemas ocorridos em razão das proporções entre as tensões de cisalhamento e tensões de esmagamento por compressão na superfície de aplicação das cargas e da antecipação da ruptura de cisalhamento por ruptura de tração na face inferior do corpo de provas. Um segundo procedimento é proposto, induzindo o esforço de cisalhamento através de puncionamento de um corpo de prova prismático simples e sem recortes, com distribuição da seção cisalhantes simetricamente em relação a um ponto. Para tanto, desenvolve-se uma ferramenta de macho e fêmea adaptado a uma prensa universal de ensaios para aplicação dos esforços. Verificada a validade do método, realiza-se um conjunto de ensaios com três espécies de madeiras, diferenciadas entre si pelas suas resistências mecânicas e, valendo-se dos métodos propostos pela norma NBR 7190/97, por SANTOS NETO (1999) e o cisalhamento por puncionamento, analisa-se e discute-se o desempenho dos três processos. / This research aims to examine the procedures and results of test methods proposed for the identification of the shear strength of wood fibers in parallel direction. Aims to observe the imperfections of existing methods, aiming to propose a new test method in which some of the problems shown can be minimized or reduced. The method proposed by NBR 7190/97 uses a rectangular prismatic body of evidence with a tooth to prevent its rotation caused by asymmetry in the application of force that causes the shear. The method proposed by SANTOS NETO (1999) also uses a prismatic body of evidence with alternating partial interruptions in cross sections, which provide requests shear at pre-selected regions. Alternatively, the paper presents two methods: the first test method suggested is analogous to the standard test, but applying the load symmetrically to shear two sections so as to prevent rotation of the body. This method revealed problems that occurred because of the proportions between the shear stresses and strains of crushing by compression on the surface of application of loads and the anticipation of breaking the shear rupture of traction on the underside of the body of evidence. A second procedure is proposed, leading to shear stress by punching a simple prismatic body of evidence and without cutouts, with the distribution of shearing section symmetrical about a point. To this end, it develops a tool of male and female adapted to press a universal test for application of effort. Verified the validity of the method, takes place a series of tests on three wood species, differentiated from each other by their mechanical stregth, and, drawing on the methods proposed by NBR 7190/97, and by SANTOS NETO (1999) and by punching shear, analyzes and discusses the performance of the three cases.
256

Avaliação in vitro das forças geradas por cadeias elásticas e molas fechadas de NiTi

Porto, Janise Bizarro Pereira January 2009 (has links)
Made available in DSpace on 2011-12-27T14:14:11Z (GMT). No. of bitstreams: 2 000424760-0.pdf: 9386318 bytes, checksum: 55f075ab7be050ba8f670a49a394022b (MD5) license.txt: 581 bytes, checksum: 44ea52f0b7567232681c6e3d72285adc (MD5) / The aim of this in vitro study was to access the strength produced by the nickel titanium closed-coil springs from three different comercial brands (American Orthodontics®, TP orthodontics® and Morelli®) as well as elastomeric chains from two brands available in the market (American Orthodontics® – Memory Chain e Morelli® – conventional) when submitted to 50% and 100% distensions from initial length and then check their strength behavior within time. Both strength values were measured within five intervals of initial 3, 4, 6 and 9 weeks. The sample included 240 nickel titanium closed-coil springs and 80 of the elastomeric chains segments were divided into 16 groups according to the type of material, either nickel titanium closed-coil spring or elastomeric chains, commercial brand and distension submitted. Each group had 20 samples, distended in 50% or 100% from initial length and were kept distended on steel plates immersed in artificial salive solution at the steady temperature of 37ºC. The strength developed by the samples was assessed through a tension test carried out by a mechanic essay machine Emic DL2000® at a 0,5mm/minute speed. The results were submitted to statistical ANOVA and Tukey tests. The NiTi closed coil springs and elastomeric chains distended 50% of the initial length showed initial force between 126. 3 and 267. 5 gf and between 192. 6 and 267. 8 gf, respectively; in the end of nine weeks the average strength was between 131. 7 and 263 gf for the NiTi closed coil springs and between 123. 7 and 141. 3 gf for elastomeric chains. Distension of 100% of initial length of the average initial force produced by the NiTi closed coil springs was between 214. 3 and 451. 5 gf and elastomeric chains between 306. 6 and 380. 5 gf, after nine weeks of average strength remained between 196. 7 and 397. 3 gf for the NiTi closed coil springs and between 179. 4 and 189. 3 gf for elastomeric chains. Such results indicated. / O objetivo do presente estudo foi avaliar, in vitro, as forças produzidas pelas molas fechadas de níquel-titânio de três marcas comerciais diferentes (American Orthodontics®, TP orthodontics® e Morelli®) e cadeias elásticas de duas marcas disponíveis comercialmente (American Orthodontics® – Memory Chain e Morelli® – convencional) quando submetidas a distensões de 50% e 100% do comprimento inicial e verificar o comportamento destas forças ao longo do tempo. As forças foram aferidas em cinco intervalos de tempo: inicial, 3, 4, 6 e 9 semanas. Para tanto 240 molas fechadas de níquel-titânio e 80 segmentos de cadeias elásticas foram divididos em 16 grupos de acordo com o tipo de material, mola fechada de níqueltitânio ou cadeia elástica, marca comercial e distensão submetida. Para cada grupo 20 amostras foram distendidas em 50% ou 100% do comprimento inicial e assim mantidas em placas de aço e imersas em solução de saliva artificial à temperatura constante de 37ºC. As forças desenvolvidas pelas amostras foram aferidas através de um teste de tração realizado por uma máquina de ensaio mecânico Emic DL2000® à velocidade de 0,5mm/minuto. Os resultados foram submetidos a testes estatísticos ANOVA e Tukey. As molas fechadas de NiTi e cadeias elásticas distendidas 50% do comprimento inicial apresentaram força inicial entre 126,3 e 267,5 gf e entre 192,6 e 267,8 gf, respectivamente; ao final de 9 semanas a média de força ficou entre 131,7 e 263 gf para as molas fechadas e entre 123,7 e 141,3 gf para as cadeias elásticas. Na distensão de 100% do comprimento inicial a média de força inicial apresentada pelas molas fechadas de NiTi ficou entre 214,3 e 451,5 gf e para as cadeias elásticas entre 306,6 e 380,5 gf; após 9 semanas a média de força permaneceu entre 196,7 e 397,3 gf para as molas fechadas de NiTi e entre 179,4 e 189,3 gf para as cadeias elásticas. Os resultados indicaram que tanto as molas fechadas de níquel-titânio como as cadeias elásticas desenvolveram forças iniciais maiores e maior taxa de degradação da força ao longo do tempo quando distendidas 100% do comprimento inicial quando comparadas a distensão de 50%. As molas fechadas de NiTi apresentaram menores percentuais de degradação da força do que as cadeias elásticas nas duas distensões avaliadas.
257

Influência de cimentos resinosos autoadesivos na deflexão de cúspides e carga de fratura de pré-molares restaurados com inlays em resina composta

Salaverry, Aurélio January 2011 (has links)
Made available in DSpace on 2011-12-27T14:14:33Z (GMT). No. of bitstreams: 2 000431091-0.pdf: 6484611 bytes, checksum: ee0b40e71498d6a5f8496211522ca10f (MD5) license.txt: 581 bytes, checksum: 44ea52f0b7567232681c6e3d72285adc (MD5) / The aim of this study was to evaluate the influence of four resin cements (one conventional and three self-adhesive) on cuspal deflection, fracture load and failure mode of endodontically treated teeth restored with composite resin inlays. Seventy-two maxillary premolars were randomly divided into four groups: G1 - sound teeth (control); G2 - cavities without restoration; G3 - RelyX ARC; G4 - RelyX U100; G5 - Maxcem Elite; G6 - SeT. The teeth from groups 2, 3, 4, 5 and 6 received mesio-occlusal-distal preparations and endodontic treatment. Impressions were made with vinyl polysiloxane and poured using type IV die stone in groups 3, 4, 5 and 6. Inlays with Z350 XT composite resin were built over each cast and luted with the resin cements. After storage in water at 37o C for 72 hours, a 200-N load was applied on the occlusal face using an 8 mm diameter metal sphere, and the cuspal deflection was measured using a micrometer. Following, the specimens were submitted to 500,000 cycles of mechanical fatigue, and the cuspal deflection was measured again. The specimens were then submitted to an axial load until failure. According to Kruskal-Wallis, group 2 (69 μm) had the highest cuspal deflection before mechanical fatigue, and did not differ statistically from group 6 (51 μm). Group 1 (4 μm), group 3 (4 μm) and group 4 (5 μm) obtained the lowest cuspal deflections, and did not differ between them. Intermediate value was obtained for group 5 (21 μm), and this group did not differ statistically from groups 3, 4 and 6. According to Wilcoxon test, there was no statistically difference between the cuspal deflection before and after mechanical fatigue only for group 3 (p=0,015). According to Kruskal- Wallis, group 1 (1902 N) had the highest fracture load, and differed statistically from the other groups. The second highest value was obtained for group 3 (980,8 N), and differed statistically from the other groups. Group 4 (670,6 N), group 5 (533,5 N), group 6 (601,3 N) and group 2 (526,6 N) did not differ between them. There was a predominance of recovery fractures for the restored groups. Composite resin inlays luted with RelyX ARC kept the cuspal deflection stability, obtained higher strength of the teeth, as well as fractures with good prognosis for rehabilitation. / O objetivo desse estudo foi avaliar a influência de quatro cimentos resinosos (um convencional e três autoadesivos) na deflexão de cúspides, carga de fratura e tipos de fratura de pré-molares com acesso endodôntico e restaurados com inlays em resina composta. Setenta e dois primeiros pré-molares foram divididos aleatoriamente em seis grupos (n=12): G1 (controle) - hígidos; G2 – cavidades sem restauração; G3 –RelyX ARC; G4 –RelyX U100; G5- Maxcem Elite; G6 –SeT. Os Grupos 2-6 receberam preparos cavitários MOD e acesso endodôntico. Os grupos 3-6 foram moldados com silicona por adição e vazados com gesso especial para confecção de inlays em resina composta Z350 XT. As restaurações indiretas foram cimentadas nas respectivas cavidades com carga de 1 Kg e fotoativadas. Após armazenagem em água destilada a 37º C por 72 horas, carga de 200 N foi aplicada na região oclusal com uma esfera de 8 mm de diâmetro acoplada na máquina de ensaio universal EMIC DL 2000, sendo medida a deflexão de cúspides com um micrômetro digital. Os corpos de prova foram então submetidos a 500. 000 ciclos de fadiga mecânica, e novo teste de deflexão de cúspides foi realizado. Em seguida, os corpos de prova foram submetidos ao ensaio de compressão até a fratura na máquina de ensaio universal. De acordo com o teste de Kruskal-Wallis, a maior deflexão de cúspides pré-fadiga foi obtida para o grupo 2 (69 μm), não diferindo estatisticamente do grupo 6 (51 μm). As menores deflexões de cúspides foram obtidas para o grupo 1 (4 μm), o grupo 3 (4 μm) e o grupo 4 (5 μm), os quais não diferiram estatisticamente entre si. Valor intermediário foi obtido para o grupo 5 (21 μm), não diferindo estatisticamente dos grupos 3, 4 e 6. De acordo com o teste de Wilcoxon, não houve diferença estatística entre a deflexão de cúspides pré e pós-fadiga apenas para o grupo 3 (p=0,015). De acordo com Kruskal-Wallis, a maior carga de fratura foi obtida para o grupo 1 (1902 N), diferindo estatisticamente dos outros grupos. Segundo maior valor foi obtido para o grupo 3 (980,8 N), diferindo estatisticamente dos outros grupos. Grupo 4 (670,6 N), grupo 5 (533,5 N), grupo 6 (601,3 N) e grupo 2 (526,6 N) não diferiram estatisticamente entre si. Para os grupos restaurados, houve predominância de fraturas recuperáveis. Inlays em resina composta cimentadas com RelyX ARC mantiveram a estabilidade da deflexão de cúspides, proporcionaram maior recuperação da resistência da estrutura dentária, assim como fraturas mais favoráveis para a reabilitação.
258

Influência dos cimentos resinosos na deflexão de cúspides e na carga de fratura de pré-molares tratados endodonticamente

Dall Agnol, Rhuy Jacob Cezarotto January 2008 (has links)
Made available in DSpace on 2011-12-27T14:14:19Z (GMT). No. of bitstreams: 2 000415566-0.pdf: 1518608 bytes, checksum: bd39955631082d183040d1bec6aef520 (MD5) license.txt: 581 bytes, checksum: 44ea52f0b7567232681c6e3d72285adc (MD5) / The aim of this split mouth randomized clinical trial was to evaluate and compare the space closure during the retraction of upper permanent canine with self-ligating"SmartClip" and conventional"Gemini" brackets. Sample complied 13 patients with Class I biprotrusion or Class II 1st division malocclusion, with an average age of 18 years and 4 months, 3 male and 10 female. All were submitted to the therapeutic extraction of two first premolars. The retraction of the upper canines was performed with elastomeric chain with 150g of force. The evaluations were performed at four times (T1 – initial, T2 – 4 weeks, T3 – 8 weeks, T4 – 12 weeks) in stone model casts. The amount of movement and the rotation of the canines as well anchorage loss of upper first molars were evaluated. The space closure measurement was made between canine and second premolar and rotation was assessed by an angle formed by the intersection of the line drawn through the canine’s contact points and the line of the palatal suture. The anchorage loss was measured by a guide adapted at the palatal rugae in stone casts at initial and end. The data obtained were subjected to Student t test considering level of significance of 5%.The results shown that selfligating bracket had an average of 0. 92 mm (+/- 0. 29) of rate movement and 8. 46o (+/- 4. 68) of the rotation of the upper canines and 0. 65 mm (+/- 0. 24) of anchorage loss; the conventional bracket had an average of 0. 84 mm (+/- 0. 22) of rate movement and 11. 77o (+/- 3. 26) of the rotation of and the upper canines and 0. 57 mm (+/- 0. 24) of anchorage loss. There was no difference (p=0. 250) in the rate of movement of the canines between the two types de brackets. The rotational control of the canines was better promoted by self-ligating bracket (p=0. 005). There was anchorage loss for both groups, with no statistical difference between them (p=0. 157). / O objetivo desse trabalho foi avaliar a influência de diferentes cimentos resinosos na deflexão de cúspides e na carga de fratura de dentes com tratamento endodôntico. Quarenta pré-molares superiores foram divididos aleatoriamente em quatro grupos: 1 – hígidos; 2 - RelyX ARC; 3 - RelyX U100; 4 - Maxcem. Os dentes dos grupos 2, 3 e 4 receberam preparos MOD, seguido de moldagem com silicone por adição e vazamento de gesso tipo IV. Sobre cada modelo foi confeccionada uma restauração inlay em resina composta Z250. As restaurações foram cimentadas com os cimentos resinosos, de acordo com cada grupo experimental, seguindo as instruções dos fabricantes. Os corpos-de-prova foram armazenados em água destilada a 37º C por 24 horas. Em máquina de ensaio universal, uma carga de 200 N foi aplicada na região oclusal com esfera de aço de 8 mm de diâmetro e, com o auxílio de um micrômetro posicionado nas faces vestibular e palatina, a deflexão das cúspides foi medida antes e após a carga. Em seguida, os corpos-de-prova foram submetidos à compressão axial com a esfera de aço até ocorrer a fratura. De acordo com ANOVA e teste de Tukey (a = 0,05), o grupo 1 apresentou a menor média de deflexão de cúspide (4μm), não diferindo estatisticamente do grupo 2 (12μm) (p>0,05). O grupo 3 (39μm) e 4 (56μm) apresentaram as maiores médias, diferindo estatisticamente dos grupos 1 e 2 (p<0,05). O grupo 1 teve a maior média de carga de fratura (1982 N), diferindo estatisticamente dos grupos 2 (690 N), 3 (465 N) e 4 (679 N), os quais não diferiram entre si. As inlays fixadas com os cimentos resinosos auto-adesivos RelyX U100 e Maxcem proporcionaram maior deflexão de cúspides. Os valores de carga de fratura para as inlays fixadas com os cimentos resinosos foram semelhantes entre si e não reproduziram a carga de fratura dos dentes hígidos.Houve predominância de falhas consideradas recuperáveis, independente do cimento resinoso empregado.
259

Correlação entre absorção de água e tração diametral de dois cimentos resinosos ortodônticos

Woitchunas, Carlos Alexandre January 2011 (has links)
Made available in DSpace on 2011-12-27T14:14:36Z (GMT). No. of bitstreams: 2 000435512-0.pdf: 973133 bytes, checksum: 14d9f2dc06508d0c9d2ae12d36de90f5 (MD5) license.txt: 581 bytes, checksum: 44ea52f0b7567232681c6e3d72285adc (MD5) / Introduction: To determine whether a correlation between water absorption and diametral tensile strength (DTS) exists, two orthodontic adhesives - one of hydrophilic (Transbond Plus Color Change), and other of hydrophobic nature (Transbond XT) - were tested.Methods: Samples were divided into 4 groups (n = 10 each) according to the variables cement type and storage condition (Group I, XT dry; Group II, XT wet; Group III, Plus dry; and Group IV, Plus wet). After measuring and weighting, samples from groups I and III were kept dry, while those from groups II and IV were immersed in distilled water for 72 h. Then, all samples were stored at 37°C for 72 h, re-weighted and re-measured. Statistical analyses assessed significant differences among the groups.Results: Water absorption was significantly higher in group IV when compared to group II (p = 0. 004). As for DTS, group IV values were significantly lower than those obtained from the other groups. A significant correlation between water absorption and diametrical tensile could not be demonstrated. Conclusion: Our results suggest that Transbond Plus Color Change samples, after immersion in distilled water, absorbs more water and has lower DTS values than those obtained from wet and dry Transbond XT samples. / Introdução: Este estudo foi conduzido com o objetivo de avaliar a correlação entre absorção de água e tração diametral de dois cimentos resinosos, um com características hidrofílicas (Transbond Plus Color Change) e outro com características hidrofóbicas (Transbond XT).Métodos: Quarenta amostras divididas em 4 grupos (n=10), de acordo com as variáveis tipo de cimento e meio de armazenagem (seco ou imerso em água destilada). Grupo I (controle): XT seco. Grupo II: XT úmido. Grupo III (controle): Plus seco. Grupo IV: Plus úmido. As amostras dos grupos I e III, medidas e pesadas, foram mantidas secas. Os grupos II e IV imersos em água destilada (100 ml) por 72 horas. Todas armazenadas em estufa (37oC, 72 horas), pesadas e medidas novamente. Para análise estatística foi utilizado o teste t de Student, análise de variância, teste de comparações múltiplas de Tukey e análise de correlação de Pearson. Nível de significância máximo de 5% para todos os testes.Resultados: Para absorção de água o grupo IV apresentou valores significativamente superiores aos do grupo II (p=0,004). Para tração diametral o grupo IV apresenta valores significativamente inferiores aos outros grupos, seguido pelo grupo III. Não houve correlação significativa entre absorção de água e tração diametral. Conclusão: Os resultados indicam que a Transbond Plus Color Change, após imersão em água destilada, absorve mais água e tem menor resistência à tração diametral do que Transbond XT imersa em água destilada ou em ambiente seco.
260

Avaliação da osseointegração de implantes de titânio submetidos a diferentes tratamentos de superfícies

Renz, Renata Pedrolli January 2007 (has links)
Made available in DSpace on 2013-08-07T18:53:53Z (GMT). No. of bitstreams: 1 000402797-Texto+Completo-0.pdf: 6535759 bytes, checksum: d71c96f436ffa7b29f0ee38a5038a7f7 (MD5) Previous issue date: 2007 / Osseointegration process is strongly related to superficial physical-chemical properties of materials applied as implants. Recent researches indicate that the development of surfaces treatments increases the efficiency of this process, influencing directly on the initial response of the cells in bone/implant interface, on rate and quality of bone tissue formation. However, the best relationship among several surface treatments processes and bone implant bonding remains unknown. The aim of this study was to evaluate in vivo osseointegration of coin shaped titanium surface treatmented implants by pull out assays according to ASTM C 633. The implants superficial morphology was characterized using MEV and rugosimetry techniques. Chemical composition was evaluated by means of EDS and XRF analyses according to NBR ISO 5832-2, while corrosion resistance was verified by Linear Polarization technique, according to ASTM F 746. The results showed that chemical composition of samples groups are in agreement with the limits recommended towards the presence of contaminants, except the brushed group. The current density values indicated passivation behavior, which is significantly lower than the maximum value allowed. The pull out assays showed that 30 days of healing period was insufficient to achieve satisfactory bone healing. The results obtained for the 60 days samples group demonstrated superficial roughness values which influenced maximum tension values. / O processo de osseointegração está fortemente ligado com as propriedades físicoquímicas superficiais dos materiais utilizados em implantes. Pesquisas recentes indicam que o desenvolvimento de superfícies texturizadas aumenta a eficiência deste processo, influenciando diretamente na resposta inicial das células na interface osso/implante, na taxa e na qualidade da formação do tecido ósseo formado. Porém, não foi verificada a melhor relação entre os diversos tipos de tratamentos de superfícies e a adesão óssea ao implante. O objetivo deste trabalho foi avaliar a osseointegração in vivo de implantes de titânio cilíndricos, submetidos a diferentes tratamentos de superfície, através de ensaio mecânico do tipo pull out, de acordo com a norma ASTM C 633. A morfologia superficial dos implantes foi caracterizada pelas técnicas de MEV e rugosimetria. A composição química foi avaliada pelas técnicas de EDS e XRF, de acordo com a norma NBR ISO 5832-2, enquanto que, para avaliar a resistência à corrosão, foi utilizada a técnica de Polarização Linear, segundo as recomendações da ASTM F 746. Os resultados indicaram que a composição química dos grupos de amostras, com exceção do escovado, atende aos limites estipulados quanto ao teor de contaminantes presentes. Os valores de densidade de corrente indicam comportamento de passivação, significativamente abaixo do valor máximo permitido pela norma. Os testes de pull out mostraram que 30 dias de cicatrização foram insuficientes para se obter crescimento ósseo satisfatório. De modo geral, pode-se dizer que os resultados obtidos para o grupo de 60 dias indicaram que os valores de rugosidade superficial influenciaram os valores de tensão máxima.

Page generated in 0.1058 seconds