Spelling suggestions: "subject:"resistência dde materiais"" "subject:"resistência dee materiais""
351 |
Evolução temporal da resistencia mecanica em laboratorio, de misturas simulando a reciclagem de pavimento asfaltico com adição de cimento portland / Temporal evolution of mechanical resistance in laboratory, of mixtures simulating asphalt pavement recycling with portland cement additionsGusmão, Claudia Betine 12 December 2008 (has links)
Orientador: João Virgilio Merighi / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil, Arquitetura e Urbanismo / Made available in DSpace on 2018-08-12T12:23:13Z (GMT). No. of bitstreams: 1
Gusmao_ClaudiaBetine_M.pdf: 2591416 bytes, checksum: b106affc2585283a589b10f376f83035 (MD5)
Previous issue date: 2008 / Resumo: O presente trabalho visa estudar o processo de reciclagem de pavimento asfaltico com
cimento Portland, atraves da analise de metodo de reciclagem, equipamentos utilizados, procedimentos empregados em campo, alem do estudo das vantagens e desvantagens do uso da reciclagem em pavimentos asfalticos. O trabalho trata ainda de uma forma detalhada o pavimento asfaltico com adicao de cimento Portland, atraves de ensaios tecnologicos simulando em laboratorio, para diferentes dosagens o comportamento mecanico em funcao do tempo do material obtido em campo. / Abstract: This work studies the process of asphalted pavement recycling with cement Portland additive through the analysis of recycling method, equipments and procedures used in the field, in addition to studying the advantages and disadvantages of the use of recycling in asphalted pavement. The work also approaches in detail the recycled asphalt pavement with Portland cement additive, through technological tests through laboratory simulation, to different dosage and the analysis of mechanical behavior through time of that material obtained in field. / Mestrado / Transportes / Mestre em Engenharia Civil
|
352 |
Influencia dos modos de ativação no grau de conversão, resitencia e morfologia da interface de união de sistemas de cimentação e adesivos / Effect of different activation modes on the degree of conversion, tensile bond strength and interfacial morphology of dual-cured cementing systems used in indirect composite restorationsArrais, Cesar Augusto Galvão 14 December 2006 (has links)
Orientador: Marcelo Giannini / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Ondontologia de Piracicaba / Made available in DSpace on 2018-08-08T01:52:29Z (GMT). No. of bitstreams: 1
Arrais_CesarAugustoGalvao_D.pdf: 8768801 bytes, checksum: bf5f97c936134b9476bb797b23d446d6 (MD5)
Previous issue date: 2006 / Resumo: A não fotoativação do sistema adesivo previamente à aplicação do cimento resinoso tem sido proposta quando sistemas de cimentação de dupla ativação (SCDA - sistemas adesivos de dupla ativação / cimentos resinosos de dupla ativação) são utilizados. Entretanto, existe uma carência de relatos científicos a respeito da efetividade dos SCDA. Os objetivos deste estudo foram: 1- avaliar a resistência de união (RU) e a morfologia da interface de união de restaurações indiretas de compósito através da utilização da microscopia confocal laser quando os sistemas adesivos de dupla ativação foram ou não fotoativados previamente à aplicação dos cimentos resinosos; 2- analisar o grau de conversão (GC), através da Espectroscopia Infravermelha Transformada de Fourier (FTIR), e a RU de SCDAs quando a fotoativação não foi realizada ou atenuada pela presença da restauração indireta; 3- avaliar o GC e resistência coesiva de sistemas de união quando utilizados diferentes unidades de fotoativação (LEDs e de luz halógena). A RU e resistência coesiva foram avaliadas através do ensaio de microtração. Para a análise em microscopia confocal laser, diferentes corantes foram incorporados nos SCDAs previamente à sua aplicação. Para a análise do GC, os SCDAs foram aplicados na superfície do diamante da unidade de reflectância total atenuada acoplada ao espectrômetro infravermelho. O GC dos sistemas de união não relacionados aos SCDAs foi obtido utilizando-se filmes de resina adesiva. Os resultados demonstraram que a não fotoativação do sistema adesivo de dupla ativação previamente à cimentação não afetou a RU, e que os valores foram até superiores para um SCDA de 4ª geração quando o agente de união não foi fotoativado. A análise em microscopia confocal laser exibiu variação nas características morfológicas da interface de união, variando de acordo com o SCDA utilizado e com o modo de ativação de ambos componentes (sistema adesivo e cimento resinoso). Para alguns SCDAs, o GC foi reduzido pela presença do disco de compósito posicionado entre o SCDA e a ponta da unidade fotoativadora. A não fotoativação dos SCDAs resultou em GC inferiores aos obtidos com exposição direta da luz. A não fotoativação da maioria dos SCDAs também resultou em valores inferiores de RU, exceto quando um sistema de 4ª geração foi utilizado. A utilização de LED resultou em GC inferior ao obtido quando a luz halógena foi utilizada mas não afetou a resistência coesiva dos sistemas adesivos avaliados. Pode-se concluir que a não fotoativação dos sistemas adesivos é uma alternativa aceitável durante a cimentação de restaurações indiretas, porém os SCDAs necessitam de luz fotoativadora para garantir adequada RU. A utilização de LEDs pode comprometer o GC dos sistemas adesivos / Abstract: The lack of light-activation of dual-cured bonding agents before the resin cement application has been an alternative technique of cementing indirect restorations when dual-cured cementing systems are used (DCS ¿ dual-cured bonding agents / dual-cured resin cements). However, few reports exist regarding the effectiveness of DCS when dual-cured bonding agents are left in the uncured state before the seating of the indirect restoration. Therefore, the aims of this study were: 1- to evaluate the microtensile bond strength (MTBS) and micromorphology of the adhesive interface of indirect restorations by confocal laser microscopy (CLSM) when the dual-cured bonding agents were left in the uncured state; 2- to analyze the degree of conversion (DC) by Fourier Transformed Infrared Spectroscopy and the bond strength of indirect restorations when DCSs were applied to the tooth and light activated or allowed to self-cure; 3- to evaluate the DC and ultimate tensile strength (UTS) of bonding agents light-activated with light curing units (LEDs and halogen light). The MTBS and UTS were analyzed using microtensile bond strength test. Different dyes were incorporated to the DCSs before they were applied to teeth for the CSLM analysis. For the DC analysis, the DSCs were applied to the diamond surface of attenuated total reflectance unit of the infrared device. The DC of the bonding agents related to the study evaluating the effectiveness of light-curing units was obtained from thin resin adhesive films. The results demonstrated that the MTBS was not affected, and the values were even higher for one 4th generation DCS, when the dual-bonding agents were left in the uncured state before the resin cement application. The CLSM analysis exhibited some variation in the micromorphological features, which depended on the DCSs and on the curing modes of bonding agents and resin cements. Some DCSs showed lower DC when pre-cured resin composite discs were used. The self-cured groups exhibited lower MTBS than the light-activated ones, except for one 4th generation DCS. The LED promoted lower DC in all bonding agents than did the halogen light. No difference in UTS was observed when LED was used. It was concluded that leaving the dual-cured bonding agent in the uncured state before seating the indirect restoration may be a reliable technique to ensure adequate MTBS, but most DCSs should be light-activated after seating the indirect restoration to provide optimal bond strength. Some LEDs can compromise the DC
of adhesive systems / Doutorado / Dentística / Doutor em Clínica Odontológica
|
353 |
Influência da incorporação de antioxidantes em diferentes sistemas adesivos na resistência de união à dentina e nanoinfiltração / Influence of antioxidants incorporation into the different adhesive systems on dentin bond strength and nanoleakageGotti, Valéria Bisinoto, 1988- 22 August 2018 (has links)
Orientador: Américo Bortolazzo Correr / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-22T02:50:31Z (GMT). No. of bitstreams: 1
Gotti_ValeriaBisinoto_M.pdf: 22569671 bytes, checksum: 63a18f68fe04710cbb552ebb07904779 (MD5)
Previous issue date: 2013 / Resumo: O resumo poderá ser visualizado no texto completo da tese digital / Abstract: The abstract is available with the full electronic document / Mestrado / Materiais Dentarios / Mestra em Materiais Dentários
|
354 |
Aplicação da simulação numérica para resolução de problemas de análise de falhas e de mecânica da fraturaAzevedo, Thiago Figueiredo 17 February 2014 (has links)
Simulation is a virtual tool that assists in the prediction of equipment behavior and it has been currently used for solving mechanical problems even before a physical prototype is tested .Together with the simulation , failure analysis is considered a tool for design optimization . Mechanics fracture, in turn, is a science that seeks to indicate whether a pre-existing crack type defect in the material can lead the component to a catastrophic fracture for normal operating strain. The aim of this work was to analyze numerical simulation importance as a tool for solving failure analysis and fracture mechanics problems in order to obtain quantitative results in response to geometric shapes and complex boundary conditions. Four cases of component failures once made were taken on this work and a complement with numerical simulation was carried out. The obtained results showed that numerical simulation is important in quantitative estimates of in service imposed stresses in the case of complex shape and boundary conditions. / A simulação é uma ferramenta virtual que auxilia na previsão do comportamento dos equipamentos sendo atualmente utilizada para resolução de problemas mecânicos antes mesmo que algum protótipo físico seja testado. Juntamente com a simulação, a análise de falhas é considerada uma ferramenta de otimização de projetos. A mecânica da fratura, por sua vez, é uma ciência que busca indicar se um defeito tipo trinca previamente existente no material pode levar o componente à fratura catastrófica para tensões normais de serviço. O objetivo deste estudo foi analisar a importância da simulação numérica como ferramenta para resolução de problemas de análise de falha e mecânica da fratura, a fim de se obter resultados quantitativos em resposta a formas geométricas e condições de contorno complexas. Foram tomados quatro estudos de casos de falhas de componentes outrora realizados e a partir estes foi realizado o complemento com a simulação numérica. Os resultados obtidos mostraram que a simulação numérica é importante na previsão quantitativa das tensões impostas em serviço para o caso de peças de forma e condições de contorno complexas.
|
355 |
Obtenção e caracterização de compósitos preparados com poliestireno expandido reciclado e pó de madeiraPoletto, Matheus 18 December 2009 (has links)
O presente trabalho tem como objetivo analisar as propriedades mecânicas, térmicas, termo dinâmico-mecânicas e morfológicas de compósitos preparados com poliestireno expandido reciclado e pó de madeira. Compósitos com diferentes teores de agente compatibilizante e diferentes teores de pó de madeira foram desenvolvidos em extrusora dupla rosca co-rotante e moldados por injeção. Os resultados obtidos demonstram que o compatibilizante com maior quantidade de anidrido maleico, menor massa molar ponderal média e utilizado em quantidade igual a 2% em massa gerou compósitos com melhores propriedades mecânicas. A melhora na adesão interfacial também foi observada através da análise termo dinâmico-mecânica. Verificou-se aumento no módulo de armazenamento, redução na altura do pico de tan δ e também menor valor do fator de adesão, associado com a maior adesão na região da interface. Para os compósitos desenvolvidos com diferentes teores de pó de madeira a densidade obtida foi semelhante a densidade teórica indicando estar de acordo com a regra das misturas. A utilização de compatibilizante reduziu o teor de vazios dos compósitos. Os resultados obtidos nos ensaios de flexão demonstraram que o módulo de flexão aumenta com a quantidade de carga e também se aproxima do comportamento previsto pela regra das misturas, entretanto os compósitos sem compatibilizante apresentaram redução na resistência a flexão com o aumento do teor de pó de madeira. No ensaio de impacto observou-se redução da resistência ao impacto com a adição de carga, porém os compósitos com compatibilizante apresentaram resultados superiores aos compósitos sem compatibilizante para todos os teores de pó de madeira. Observou-se aumento no módulo de armazenamento, no módulo de perda e também na efetividade do reforço com a adição de pó de madeira. Ocorreu redução na largura e também na altura do pico de tan δ conforme a adição das partículas de madeira, contudo os compósitos com compatibilizante apresentaram redução mais acentuada devido à melhora na adesão interfacial. O modelo teórico para predizer o comportamento do módulo de armazenamento demonstrou proximidade com os valores experimentais para baixos teores de carga. Para tan δ o modelo teórico se mostrou inadequado. As micrografias dos compósitos sem compatibilizante indicaram arrancamento e a presença de vazios entre o pó de madeira e a matriz, entretanto os compósitos com compatibilizante demonstraram maior recobrimento das partículas de madeira pela matriz. A estabilidade térmica dos compósitos com compatibilizante foi reduzida para todos os teores de pó de madeira quando comparada aos compósitos sem compatibilizante. / The present work aims to analyze the mechanical, thermal, dynamicalmechanical thermal properties and morphology of composites based on recycled polystyrene and wood flour. Composites with different types and levels of coupling agent and also with different levels of wood flour were developed in a co-rotating twin-screw extruder and injection molded. The results show that the coupling agent with higher amount of maleic anhydride, lower weight average molecular weight and used in to 2% by weight produced composites with better mechanical properties. The improvement in interfacial adhesion was also observed by dynamical-mechanical thermal analysis. An increase in the storage modulus, decrease in peak height and also lower value of adhesion factor, was observed due to the improved on interfacial adhesion. For the composites developed with different levels of wood flour density obtained was similar to theoretical density indicating that in accordance with the rule of mixtures. The use of coupling agent reduced the concentration of voids in the composites. The flexural modulus increases with the amount of wood flour and also approaches the behavior predicted by the rule of mixtures, however the composites without coupling agent showed reduction in flexural strength. The impact strength decreases with the addition of wood flour, but the composites with coupling agent showed better results than the composite without coupling agent for all levels of wood flour. There was an increase in the storage modulus, loss modulus and also the efficiency of filler with the addition of wood flour. There was a reduction in width and also in peak height of tan δ as the addition of wood particles, composite with coupling agent demonstrated greater reduction due to improved on interfacial adhesion. The theoretical model to predict the behavior of the storage modulus showed proximity with the experimental values for low levels of filler. Theoretical model for tan δ proved inadequate. The micrographs of composites without coupling agent indicated the presence of pulled-out traces and gaps between the wood flour and matrix, however the composites with coupling agent show the strong bonding and good wetting of the fillers by the matrix. The thermal stability of composites with coupling agent was reduced for all levels of wood flour when compared to composites without coupling agent.
|
356 |
Influência da argamassa de revestimento na resistência à compressão em prismas de alvenaria resistente de blocos de concreto / The influence of the covering mortar in the axial compressive strength of masonry prisms composed of concret blocks of non load-bearing masonryAraújo Neto, Gilberto Nery de 09 June 2006 (has links)
Made available in DSpace on 2017-06-01T17:57:28Z (GMT). No. of bitstreams: 1
gilberto nery.pdf: 1716064 bytes, checksum: 9c4218702694b75ecbe1b4a033ddafa0 (MD5)
Previous issue date: 2006-06-09 / In the Metropolitan Region of Recife some buildings had been constructed where the masonry fulfills function structural been, however, composed of blocks originally
confectioned for non load-bearing masonry. This constructive system is regionally known as "coffin buildings". To take handle of the correct evaluation of the conditions of a building like these, it must be considered all the factors that, somehow, has some influence at the stability or durability of it. The present work had as objective to evaluate the influence of the covering mortar in the axial compressive strength of masonry prisms composed of concrete blocks of non load-bearing masonry. The tests had been carried through with prisms of three lined up blocks, where six samples, with fifteen copies each, had been confectioned. To minimize the effect of other variable, all prisms had been confectioned under the same conditions and with identical materials. The samples are: naked blocks; blocks with base to covering; blocks with base to covering and mortar with thicknesses 1,5 cm and 3 cm and traces 1:2:9 (weak) and 1:1:6 (average). The materials had been tested to define its characteristics. All the prisms had been breached at a hydraulical press for to define its respective resistances to the axial compression and the results, later, were statistically treated. It had a considerable increment at the resistance to the compression of the covered prisms and the mortar s resistance revealed influent to the resistance of the prism and the standards of rupture in the majority of the cases / Na Região Metropolitana de Recife foram construídos vários edifícios onde a alvenaria cumpre função estrutural, porém é composta de blocos originalmente confeccionados para vedação. Esse sistema construtivo é conhecido regionalmente
como "edifícios caixão". Para se levar a cabo a correta avaliação das condições de um edifício destes, há de se levar em conta todos os fatores que de alguma forma influenciem na estabilidade ou durabilidade do mesmo. O presente trabalho teve como objetivo avaliar a influência da argamassa de revestimento na resistência à compressão de prismas de alvenaria compostos por blocos de vedação de concreto. Os ensaios se realizaram em prismas de 3 blocos alinhados, onde foram confeccionadas 6 amostras com 15 réplicas cada. Para minimizar os efeitos de outras variáveis, todos os prismas
foram confeccionados sob as mesmas condições e com materiais idênticos. As amostras são: blocos nus; blocos com chapisco; blocos com chapisco e argamassa com espessuras
1,5 cm e 3 cm e traços 1:2:9 (fraco) e 1:1:6 (médio). Os materiais usados na confecção dos prismas foram ensaiados para definição de suas características. Todos os prismas
foram rompidos em prensa hidráulica para definição das respectivas resistências à compressão axial e os resultados, posteriormente, tratados estatisticamente. Houve um
incremento considerável nas resistências à compressão dos prismas com revestimento e a resistência da argamassa mostrou-se influenciadora da resistência do prisma e nos
padrões de ruptura na maioria dos casos. A aderência do revestimento mostrou-se ponto de fragilidade, principalmente nos prismas com revestimento de 3,0 cm de espessura
|
357 |
Análise comparativa do módulo de elasticidade calculado segundo diferentes normasCabral, Larissa Marques Cunha 09 June 2014 (has links)
Made available in DSpace on 2017-06-01T17:57:34Z (GMT). No. of bitstreams: 1
larissa_marques_cunha_cabral.pdf: 1240575 bytes, checksum: 527cd5d555a68768c684554d8e1cccd1 (MD5)
Previous issue date: 2014-06-09 / The work involved studying the behavior and adjustment of dosage diagram of concrete with respect to static and dynamic elastic modulus. Furthermore, it compares the models of the static elastic modulus based on the compressive strength, German, European, American and Brazilian ABNT NBR 6118 (2014) prediction - Design of Concrete Structures: procedure. Two concrete were produced with different consistency; plastic and other fluid (selfcompacting).
Three traits were developed for each consistency, totaling six traits. These dosages were as varying the water / cement and cement consumption; the rebate was kept constant. A comparative analysis of the experimental results with those predicted by some standards was carried out to evaluate the level of accuracy of the same. ACI 318 (2014) was the standard that had their closest results compared to NBR 6118 (2014). Have the Eurocode and DIN 1045 standards -2 showed similar results. And the standard fib CEB - 2010, showed
overestimated values in relation to other standards. Thus, we can say that the determination of elasticity of the concrete module proved consistent with the materials and dosages used. However, it is very sensitive to the composition of the trace variable, even when kept the
materials. The compressive strength is one of the variables that affect the results. However, it also has great influence to change the nature of the coarse aggregate and the relative folder / coarse aggregate, for example. The dynamic ultrasonic waves through the module was also
measured and compared with the static module, showing a rapid and non-destructive option to evaluate the modulus of elasticity of the concrete. / O trabalho em questão estuda o comportamento e adequação do diagrama de dosagem do concreto com relação ao módulo de elasticidade estático e dinâmico. Além disso, compara os modelos de previsão do módulo de elasticidade estático baseados na resistência à compressão das normas americana, alemã, européia, fib e a brasileira ABNT NBR 6118 (2014) - Projeto de Estruturas de Concreto: procedimento. Foram produzidos dois concretos com consistências
distintas; uma plástica e outra flúida (auto adensável). Foram desenvolvidos três traços para cada consistência, totalizando assim seis traços. Essas dosagens tiveram como variáveis a relação água/cimento e o consumo de cimento; o abatimento foi mantido constante. Uma análise comparativa entre os resultados experimentais com os valores previstos por algumas normas foi realizada, avaliando o nível de precisão das mesmas. A ACI 318 (2014) foi a norma que teve seus resultados mais próximos em relação a NBR 6118 (2014). Já as normas EUROCODE 2 (2004) e DIN 1045 apresentaram resultados semelhantes. E a norma fib CEB 2010, apresentou valores superestimados em relação às demais normas. Assim, é possível
afirmar que a determinação do módulo de elasticidade do concreto se mostrou coerente com os materiais e dosagens utilizadas. Contudo, é uma variável muito sensível à composição do traço, mesmo quando mantidos os materiais. A resistência à compressão é uma das variáveis que interfere nos resultados. Entretanto, tem também grande influência a variação da natureza dos agregados graúdos e a relação pasta/agregado graúdo, por exemplo. O módulo dinâmico
através de ondas ultrassônicas, também foi medido e comparado com o módulo estático, mostrando-se uma opção rápida e não destrutiva de avaliar o módulo de elasticidade do concreto.
|
358 |
Efeito de diferentes modelos de envelhecimento na resistência de união em dentina decídua hígida e cariada / Different degradations models to evaluate bond strength in sound and caries primary dentinCalvo, Ana Flávia Bissoto 04 March 2015 (has links)
A resistência de união (RU) dos materiais deve ser avaliada após a degradação da interface adesiva, tentando simular um processo que ocorre naturalmente ao longo do tempo na cavidade bucal. O presente estudo avaliou a degradação da interface adesiva em diferentes materiais utilizando o modelo de envelhecimento in vitro e in situ em dentina hígida e cariada. Noventa segundos molares decíduos hígidos e sem defeitos de esmalte, foram aleatoriamente divididos em dois grupos de acordo com o substrato a ser testado (hígido e com lesão de cárie induzida). A seguir, cada um dos grupos foi subdividido aleatoriamente de acordo com o material restaurador (n=15): resina composta associada ao sistema adesivo - RC, cimento de ionômero de vidro modificado por resina - CIVMR e cimento de ionômero de vidro de alta viscosidade - CIVAV. A superfície da dentina foi preparada e com o auxílio de cânulas de polietileno, foram confeccionados os espécimes com os materiais restauradores. Partes de um mesmo dente foram submetidas a cada envelhecimento: in vitro (24 horas e 6 meses) - armazenados em água destilada à 37°C; e in situ (uso de dispositivo intraoral palatino por voluntários em uma fase experimental de 7 dias). Os espécimes foram submetidos ao teste de microcisalhamento (MPa) para avaliação da RU, seguido de análise do padrão de fratura em estereomicroscópio (400X). Os dados foram submetidos a análise de variância de medidas repetidas seguida pelo teste de Bonferroni (? = 5%). De forma geral, o armazenamento por seis meses em água degradou o grupo CIVMR em dentina hígida (<0,001) e RC em dentina cariada (p=0,007), para os outros materiais não houve diferença estatística (p=1,00). O modelo in situ influenciou negativamente os valores de RU nos grupos RC e CIVMR (p<0,001) no substrato hígido e na RC (p<0,001), CIVMR (p=0,001) e CIVAV p=0,020) no substrato cariado. Concluí-se que no modelo in vitro, seis meses em água destilada não foram suficientes para degradar a interface de união dos materiais avaliados e o modelo in situ é uma metodologia rápida que pode ser utilizada para avaliar a degradação da interface de união de materiais restauradores em dentina cariada de dentes decíduo. / Materials bond strength (BS) should be evaluated after degradation of the adhesive interface, simulating the intra-oral enviroment. This study assessed the degradation of the bonding interface of differents materials using in vitro and in situ models of aging in sound and caries - affected primary dentin. Ninety sound second primary molars without enamel defects were randomly assigned into two groups (sound and induced carious) according to the substrate to be tested. Then each group was subdivided according to the restorative material (n=15): composite resin associated with the adhesive system - CR, resin-modified glass ionomer cement - RMGIC or high-viscous glass ionomer cement- HVGIC. Dentin surface was prepared and with the aid of polyethylene tubes specimens of each restorative materials were prepared. Parts of a same tooth were subjected to in vitro and in situ models of aging. For in vitro model, the specimens were stored in distilled water at 37°C during 24 hours per 6 months; and for in situ model an intraoral palatal device was confectioned and used by volunteers in an experimental phase for 7 days. Specimens were submitted to microshear test (MPa) for BS evaluation and then stereomicroscopy (400X) analys of failure mode. Data were analyzed by repeated measures ANOVA for followed by Bonferroni test (? = 5%). In general, the storage for six months in distilled water degraded the RMGIC group in sound dentin (<0.001) and RC group in caries-affect dentin substrate (p = 0.007), for the others materials there was no statistical difference (p = 1.00). The in situ model, adversely, influenced the BS in RC and RMGIC groups (p <0.001) in sound substrate, and in RC (p <0.001), RMGIC (p = 0.001) and HVGIC (p = 0.020) in caries-affected dentin. We can concluded that in in vitro model, using six months distilled water, was not sufficient to degrade the bonded interface of the evaluated materials and in situ model is a faster method to evaluate degradation of the adhesion interface of restorative materials in cariesaffected dentin.
|
359 |
Aplicação do método de Neuber para obtenção de tensões não-lineares em componentes automotivos fabricados em ferro fundido nodular. / Application of the Neuber method to obtain nonlinear stresses in automotive components made of nodular cast iron.Assano, Luiz Henrique de Moraes 23 March 2018 (has links)
As análises de tensões não-lineares por elementos finitos situadas no regime plástico do material demandam maior tempo de processamento computacional quando comparadas às análises lineares situadas no regime elástico. Os valores de tensões não-lineares podem ser obtidos por meio de metodologias analíticas de previsão de tensão aplicadas a componentes entalhados. Entre os métodos de obtenção de tensão em entalhes, destaca-se o método de Neuber. O presente trabalho visa avaliar a aplicação deste método aliado à análise de elementos finitos para a obtenção de tensões não-lineares em componentes automotivos fabricados em ferro fundido nodular contendo descontinuidades geométricas na superfície. Como referência foram utilizados valores de tensões obtidos através da técnica de extensometria, aplicados em dois diferentes modelos de alavancas contidas em transmissões de ônibus e caminhões. Todos os dados de entrada para os cálculos de elementos finitos foram obtidos através da caracterização do material por meio da realização de ensaios de dureza, tração e metalografia. A fim de verificar possíveis trincas ocasionadas pelos carregamentos aplicados, os componentes testados foram submetidos a ensaios de partículas magnéticas. Busca-se, assim, uma contribuição para a redução do tempo de desenvolvimento de novos produtos fabricados em componentes de ferro fundido nodular. / The analyzes of nonlinear stresses by finite elements located in the plastic regime of the material demand a longer time of computational processing when compared to the linear analyzes located in the elastic regime. The values of nonlinear stresses can be obtained by analytical methodologies of stress prediction applied to notched components. Among the methods of obtaining stresses in notches, the Neuber method is outstanding. The present work aims to evaluate the application of this method, combined with the finite element analysis to obtain nonlinear stresses in automotive components made of nodular cast iron containing geometric surface discontinuities. As reference, stress values obtained through the strain gauge technique were used, applied in two different shift levers contained in bus and truck transmissions. All input data for the finite element calculations were obtained through the characterization of the material by means of hardness, tensile and metallography tests. In order to verify possible cracks caused by the applied loads, the tested components were subjected to magnetic particle tests. Thus, a contribution is made to reduce the development time of new products manufactured in nodular cast iron components.
|
360 |
Caracterização experimental do comportamento mecânico sob solicitação multiaxial em junções de chapas AA2024-T3 soldadas por fricção-mistura (\'FSW\'). / Experimental characterization of the mechanical behaviour under multiaxial loads of AA2024-T3 sheets welded by friction stir welding (FSW).Cerveira, Renato Luiz Lehnert Portela 02 September 2008 (has links)
Este trabalho tem o intuito de analisar a junção realizada pelo processo de soldagem por fricção-mistura (FSW) pelo do teste de Arcan. É apresentada inicialmente uma revisão bibliográfica dos estudos já realizados nessa área e da teoria relevante. Foram realizados ensaios para avaliar a falha da junta sob carregamento multiaxial quando comparada à falha do material base. Para a realização dos ensaios utilizouse uma máquina de tração com capacidade de 50 kN. Foi projetado e construído um dispositivo de Arcan modificado, que permite a variação do ângulo com o qual a força de tração é aplicada. Os resultados práticos demonstraram as características de resistência da junção por FSW quando sujeita à forças de tração e cisalhamento. Os resultados obtidos servem como base para comparação entre junções feitas por FSW e por métodos convencionais como a utilização de rebites (prática muito comum na indústria aeronáutica). / The aim of this work is to analyze the junction made by Friction Stir Welding (FSW) using the Arcan test. Initially is presented a review of the studies carried out in this area and the relevant theory for the project. Tests were executed in order to evaluate the failure of the welding under multiaxial loading when compared to the failure of the base material. In order to execute the Arcan Tests, a tensile test machine with nominal capacity of 50 kN was used. A modified Arcan device, that allows an angle variation of the force applied, was developed and fabricated. The practical results demonstrate the FSW joint resistance characteristics when subjected to normal and shear forces. The results obtained serve as basis to compare the junctions made using FSW and conventional joint methods like rivets (very common practice in the aeronautical industry).
|
Page generated in 0.1282 seconds