41 |
Desenvolvimento de fontes radioativas seladas imobilizadas em resina epóxi para verificação de detectores utilizados em medicina nuclear / Development of sealed radioactive sources immobilized in Epoxy resin for verification of detectors used in nuclear medicineTIEZZI, RODRIGO 22 June 2016 (has links)
Submitted by Claudinei Pracidelli (cpracide@ipen.br) on 2016-06-22T11:16:05Z
No. of bitstreams: 0 / Made available in DSpace on 2016-06-22T11:16:05Z (GMT). No. of bitstreams: 0 / Dissertação (Mestrado em Tecnologia Nuclear) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
|
42 |
Estudo dos parâmetros dosimétricos de sementes de Iodo-125 desenvolvidas pelo IPEN-CNEN/SP utilizadas em braquiterapia por simulação computacional pelo método de Monte Carlo / Study of dosimetric parameters for iodine-125 brachytherapy sources development from IPEN-CNEN/SP using Monte Carlo MethodOLIVEIRA, TIAGO B. de 22 June 2016 (has links)
Submitted by Claudinei Pracidelli (cpracide@ipen.br) on 2016-06-22T14:06:41Z
No. of bitstreams: 0 / Made available in DSpace on 2016-06-22T14:06:41Z (GMT). No. of bitstreams: 0 / Dissertação (Mestrado em Tecnologia Nuclear) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
|
43 |
Desenvolvimento e construção de sistema automatizados para controle de qualidade na produção de sementes de iodo-125 / Development and construction of an automated system for quality control in the iodine-125 seeds productionMOURA, JOAO A. 01 July 2016 (has links)
Submitted by Claudinei Pracidelli (cpracide@ipen.br) on 2016-07-01T11:08:37Z
No. of bitstreams: 0 / Made available in DSpace on 2016-07-01T11:08:37Z (GMT). No. of bitstreams: 0 / Tese (Doutorado em Tecnologia Nuclear) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
|
44 |
Desenvolvimento de fontes radioativas seladas imobilizadas em resina epóxi para verificação de detectores utilizados em Medicina Nuclear / Development of sealed radioactive sources immobilized in Epoxy resin for verification of detectors used in nuclear medicineRodrigo Tiezzi 04 February 2016 (has links)
As fontes radioativas seladas são usadas na verificação de detectores de câmara de ionização, os quais medem a atividade dos radioisótopos usados nas mais diversas áreas, como na Medicina Nuclear. A medida da atividade dos radioisótopos deve ser feita com exatidão, pois será administrada em um paciente. Para garantir o adequado funcionamento dos detectores de câmara de ionização, são estipulados ensaios normatizados pela Agência Internacional de Energia Atômica (IAEA) e a Comissão Nacional de Energia Nuclear (CNEN) utilizando-se fontes radioativas seladas de Bário-133, Césio-137 e Cobalto-57. Os testes avaliam a exatidão, precisão, reprodutibilidade e linearidade da resposta do equipamento. O foco deste trabalho foi o estudo e o desenvolvimento dessas fontes radioativas padrão de Bário-133, Césio-137 e Cobalto-57, utilizando um polímero, no caso resina epóxi comerciais do tipo éter diglicidílico do bisfenol A e um agente de cura a base de poliamina modificada da dietilenotriamina ,para imobilizar o material radioativo. A matriz polimérica apresenta a função primordial de fixar e imobilizar o conteúdo radioativo não permitindo seu vazamento dentro dos limites técnicos exigidos pelas normas de proteção radiológica no quesito de características de uma fonte selada e, adicionalmente, ter a capacidade de reter a emanação de quaisquer gases que venham a se formar durante o processo de fabricação e do período de vida útil deste artefato. O processo de manufatura de uma fonte selada padrão consiste no envasamento, em um frasco de geometria padronizada, de uma quantidade, em volume fixo, de uma matriz polimérica no interior da qual é adicionada e dispersada homogeneamente uma quantidade precisa e exata em atividade de um material radioativo padrão. Nesse sentido, realizou-se um estudo para a escolha da resina epóxi, analisando suas características e propriedades. Foram realizados estudos e testes, verificando a máxima miscibilidade da resina com a água (solução ácida, simulando as condições da solução radiativa), perdas de propriedades mecânicas e térmicas, bem como o controle de dose radioativa para a completa cura (irradiadores de cobalto).Foram produzidas fontes de césio-137 e bário-133, realizou-se testes para determinação do grau de homogeneidade na dispersão do material radioativo na matriz e testes de imersão das fontes seladas produzidas para verificar a estanqueidade do sistema desenvolvido, obtendo um resultado satisfatório de acordo com as normas. Analisando todos os resultados obtidos, as fontes seladas podem ser confeccionadas em matriz epóxi DGEBA e endurecedor poliamínico DETA modificado, desde que a quantidade de material radioativo, na forma de solução ácida, adicionado à composição não ultrapasse um teor de 20%. A cura da resina epóxi pode ser melhorada em relação a ambiente, com uso da irradiação desde que seja exposta a uma dose ao redor de 33 kGy durante a cura. Nos testes de estanqueidade, verificou-se que as fontes são estanques, as medições da atividade da água utilizada nos testes mostraram um valor inferior a 185 Bq (de acordo com a International Standard Organization- Radiation protection sealed radioactive sources - ISO 9978), comprovando a eficiência da resina epóxi como material para selar o material radioativo. Tendo a finalidade de criar uma tecnologia nacional capaz de suprir a demanda deste produto no mercado interno e atingir excelência em qualidade através da acreditação e certificação do produto junto aos órgãos competentes. / The radioactive sealed sources are used in verification ionization chamber detectors, which measure the activity of radioisotopes used in several areas, such as in nuclear medicine. The measurement of the activity of radioisotopes must be made with accuracy, because it is administered to a patient. To ensure the proper functioning of the ionization chamber detectors, standardized tests are set by the International Atomic Energy Agency (IAEA) and the National Nuclear Energy Commission using sealed radioactive sources of Barium-133, Cesium-137 and Cobalt-57. The tests assess the accuracy, precision, reproducibility and linearity of response of the equipment. The focus of this work was the study and the development of these radioactive sources with standard Barium-133 and Cesium-137, using a polymer, in case commercial epoxy resin of diglycidyl ether of bisphenol A (DGEBA) and a curing agent based on modified polyamine diethylenetriamine (DETA), to immobilize the radioactive material. The polymeric matrix has the main function of fix and immobilize the radioactive contents not allowing them to leak within the technical limits required by the standards of radiological protection in the category of characteristics of a sealed source and additionally have the ability to retain the emanation of any gases that may be formed during the manufacture process and the useful life of this artifact. The manufacturing process of a sealed source standard consists of the potting ,into bottle standardized geometry, in fixed volume of a quantity of a polymeric matrix within which is added and dispersed homogeneously to need and exact amount in activity of the radioactive materials standards. Accordingly, a study was conducted for the choice of epoxy resin, analyzing its characteristics and properties. Studies and tests were performed, examining the maximum miscibility of the resin with the water (acidic solution, simulating the conditions of radioactive solution), loss of mechanical and thermal properties, as well as the radioactive dose control for complete curing (cobalt irradiators). For this work was produced a sources of barium-133 and cesium -137,tests were conducted to determination the degree of homogeneity in the dispersion of the radioactive material in the matrix and immersion tests of sealed sources produced to verify the leakage (ISO 9978) of the developed system, occurring obtaining a satisfactory result. With the purpose of creating a national technology able to meet the demand of this product in the domestic market and achieve excellence in quality through accreditation and certification of the product by the appropriate bodies.
|
45 |
Efeitos termicos e de graus de umidade constantes na liberação da dormencia de sementes de Brachiaria brizantha (Hochst. ex A. Rich) Stapf / Thermal and moisture content on storability and seed dormancy releasing of Brachiaria brizantha (Hochst. ex A. Rich.) StapfCavalcante Filho, Francisco Nahum 16 February 2006 (has links)
Orientador: Roberto Usberti / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Agricola / Made available in DSpace on 2018-08-06T12:29:48Z (GMT). No. of bitstreams: 1
CavalcanteFilho_FranciscoNahum_M.pdf: 999790 bytes, checksum: b6fe814b4fe9db3c1d4b9f5196d0287a (MD5)
Previous issue date: 2006 / Resumo: As sementes do gênero Brachiaria apresentam um mecanismo duplo de dormência, mais pronunciado em sementes recém colhidas, conduzindo a valores abaixo dos de viabilidade obtidos pelo teste de Tetrazólio e, deste modo, dificultando a tomada de decisões para o armazenamento, comercialização e fiscalização do comércio dessas sementes. Utilizando-se a tecnologia de detecção das constantes da equação de viabilidade de sementes, baseada em altas temperaturas de armazenamento e graus de umidade constantes, foi possível neste experimento isolar o efeito das temperaturas de 40, 50 e 65°C na liberação da dormência de sementes dos cultivares Marandu, Mulato 1 e Mulato 2 de Brachiaria brizantha, armazenadas com graus de umidade constantes, de 1,9 a 17,8%. As sementes apresentaram altos índices de dormência, detectada pelo teste de tetrazólio e liberada pela escarificação química e parcialmente pelo teste de envelhecimento acelerado. Não foram observadas diferenças para a velocidade de germinação (T50); entretanto ocorreram diferenças quanto ao número de sementes por grama. O padrão das isotermas de sorção e desorção foi semelhante para os cultivares. Os melhores resultados para liberação de dormência a 40°C foram obtidos nos graus de umidade de 9,5 e 8,5% para os cultivares Marandu e Mulato 1, respectivamente; a 50°C foram detectadas liberações de dormência em todos os graus de umidade testados e os melhores resultados foram obtidos para o cultivar Marandu (7,6 e 10,3%) e Mulato 1 (8,3%). As liberações de dormência a 65°C não foram tão evidentes em todos os graus de umidade testados. O cultivar Marandu apresentou maior armazenabilidade durante todo o experimento / Abstract: Brachiaria species normally show a double seed dormancy mechanism, mainly on fresh-harvest seeds, leading to germination percentages lower than those of viability detected by Tetrazolium test, so causing problems as to storage, trading and seed inspection activities. Using the methodology to detect the constants of the viability equation (high storage temperatures and fixed moisture contents) it was feasible in this research to isolate the effects of 40, 50 and 65°C on Brachiaria brizantha cultivars Marandu, Mulato 1 and Mulato 2 seed dormancy releasing, after storage at moisture contents ranging from 1.9 and 17.8%. Seed samples used presented high seed dormancy levels, detected by Tetrazolium test and it was released by chemical scarification and partially by accelerated ageing test. No statistical differences were observed as to speed of germination (T50); however, differences were detected as to number of seed per gram among cultivars. Sorption and desorption isotherm curves were similar for the cultivars. The best results of seed dormancy releasing at 40°C were achieved at 9.5 and 8.5% moisture content, for cultivars Marandu e Mulato 1 respectively; seed dormancy releasing results were obtained at 50°C for all moisture content studied and the best results were achieved for cultivars Marandu (7.6 e 10.3%) and Mulato 1 (8.3%). At 65°C seed dormancy releasing results were not clear. The cultivar Marandu presented higher storability than the others throughout the experiment / Mestrado / Tecnologia Pós-Colheita / Mestre em Engenharia Agrícola
|
46 |
Avaliação da alteração nas propriedades da pasta de cimento em ambiente de repositório / Assessment of cement paste properties changes in repository environmentFERREIRA, EDUARDO G.A. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:36:01Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T13:59:48Z (GMT). No. of bitstreams: 0 / Pasta de cimento é um material comum em repositórios para rejeitos radioativos, atuando como material estrutural e de imobilização. Sua utilização como material de preenchimento em um repositório tipo poço tubular profundo para fontes seladas, no entanto, requer um maior tempo de vida útil do material. O conhecimento de seu comportamento em longo prazo é necessário para garantir a segurança da instalação em milhares de anos. O presente trabalho avaliou as alterações na pasta de cimento induzidas por fatores de degradação, como ataque de agentes agressivos, alta temperatura e presença de campo de radiação. Corpos de prova (cps) de pasta de cimento foram submetidos a ensaios acelerados de degradação e os efeitos deletérios foram avaliados por meio de ensaios de resistência mecânica, variação dimensional, lixiviação/penetração de íons, DRX, TGA e MEV. Observou-se que a hidratação dos cps foi beneficiada pela imersão (em água destilada ou em solução salina) e alta temperatura, resultando em uma resistência maior. O armazenamento à seco prejudicou a hidratação, mantendo a resistência mais baixa. O tempo de imersão e a irradiação não foram capazes de alterar a mineralogia e a resistência da pasta de cimento. / Dissertação (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
|
47 |
Estudo e levantamento de parametros para montagem de um laboratorio de producao de fontes radioativas utilizadas na verificacao de equipamentos / Study and survey of assembling parameters to a radioactive source production laboratory used to verify equipmentsGAUGLITZ, ERICA 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:27:28Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:07:44Z (GMT). No. of bitstreams: 0 / Este trabalho apresenta o levantamento de parâmetros para implementação adequada e segura de pisos, portas, janelas, bancadas, capelas entre outros, de um laboratório radioquímico. A disposição de cada item segue orientações de guias, normas nacionais da Comissão Nacional de Energia Nuclear (CNEN) e internacional da Agencia Internacional de Energia Atômica (IAEA), com objetivo de garantir a proteção radiológica do trabalhador e do ambiente. A disposição adequada dos itens do laboratório radioquímico, garante a qualidade e segurança na produção de fontes radioativas seladas de 57Co 137Cs e 133Ba com atividades 185, 9.3 e 5.4 MBq respectivamente. Estas fontes são utilizadas na verificação de medidores de atividade, equipamento que todo Centro de Medicina Nuclear deve ter disponível segundo recomendações da norma CNEN-NN-3.05 Requisitos de Radioproteção e Segurança para Serviços de Medicina Nuclear para verificação da atividade de radiofármacos que serão administrados nos pacientes para fins de diagnóstico e terapia. Um medidor de atividade fora adquirido pelo laboratório de produção de fontes, com o qual foram realizados os testes de precisão, exatidão, reprodutibilidade e linearidade, que devem apresentar resultados dentro dos limites estabelecidos na norma CNEN-NN-3.05. / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
|
48 |
Caracterização do filme radiocrômico GAFCHROMIC modelo EBT3 para uso em braquiterapia / Characteristics of the film radiochromic gafchromic EBT3 model for use in brachytherapyLUVIZOTTO, JESSICA 08 April 2016 (has links)
Submitted by Claudinei Pracidelli (cpracide@ipen.br) on 2016-04-08T12:52:45Z
No. of bitstreams: 0 / Made available in DSpace on 2016-04-08T12:52:45Z (GMT). No. of bitstreams: 0 / A braquiterapia é a modalidade de tratamento radioterápico que utiliza fontes radioativas seladas a uma distância curta do tumor, diminuindo o risco de aplicação de uma dose indesejável em tecidos sadios adjacentes. Para que a braquiterapia seja confiável, é necessário estabelecer um programa de práticas dosimétricas visando a determinação da dose ideal de radiação para esta prática radioterápica. Neste trabalho apresenta a aplicação de duas metodologias destinadas à dosimetria utilizando filmes radiocrômicos. Medidas experimentais foram realizadas com filmes EBT3 em objetos simuladores composto de material homogêneo e heterogêneo (pulmão, osso e tecidos moles) construídos especialmente para medidas de dose em braquiterapia. Os processamentos e analises das imagens resultantes do procedimento experimental foram realizados com o software IMAGEJ e MATLAB. Os resultados foram avaliados a partir de comparações medidas experimentais de dose e obtidas por simulações pelo Método de Monte Carlo. / Dissertação (Mestrado em Tecnologia Nuclear) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
|
49 |
Estudo dos parâmetros dosimétricos de sementes de Iodo-125 desenvolvidas pelo IPEN-CNEN/SP utilizadas em braquiterapia por simulação computacional pelo método de Monte Carlo / Study of dosimetric parameters for iodine-125 brachytherapy sources development from IPEN-CNEN/SP using Monte Carlo MethodOLIVEIRA, TIAGO B. de 22 June 2016 (has links)
Submitted by Claudinei Pracidelli (cpracide@ipen.br) on 2016-06-22T14:06:41Z
No. of bitstreams: 0 / Made available in DSpace on 2016-06-22T14:06:41Z (GMT). No. of bitstreams: 0 / As expectativas da Organização Mundial de Saúde para o ano de 2030 são que o número de mortes por câncer seja de aproximadamente 13,2 milhões, evidenciando a elevada parcela desta doença no problema de saúde mundial. Com relação ao câncer de próstata, de acordo com o Instituto Nacional do Câncer, o número de casos diagnosticados no mundo em 2012 foi de aproximadamente 1,1 milhão, enquanto que no Brasil os dados indicam a incidência de 68 mil novos casos. O tratamento deste tipo de neoplasia pode ser realizado com cirurgia (prostatectomia) ou radioterapia. Dentre a radioterapia, podemos destacar a técnica de braquiterapia, a qual consiste na introdução (implante) de pequenas fontes radioativas (sementes) no interior da próstata, onde será entregue um valor elevado de dose no volume de tratamento e baixa dose nos tecidos ao redor. No Brasil, a classe médica estima uma demanda de aproximadamente 8000 sementes/mês, sendo o custo unitário de cada semente de pelo menos U$ 26,00. A Associação Americana de Físicos na Medicina publicou alguns documentos descrevendo quais parâmetros e análises devem ser realizadas para avaliações da distribuição de dose, como por exemplo, os parâmetros Constante de taxa de dose, Função radial e Função de anisotropia. Estes parâmetros podem ser obtidos através de medidas experimentais da distribuição de dose ou por simulações computacionais. Neste trabalho foram determinados os parâmetros dosimétricos da semente OncoSeed-6711 da empresa Oncura-GEHealthcare e da semente desenvolvida pelo Grupo de Dosimetria de Fontes de Braquiterapia do Centro de Tecnologia das Radiações (CTR IPEN-CNEN/SP) por simulação computacional da distribuição de dose utilizando o código MCNP5, baseado no Método de Monte Carlo. A semente 6711 foi modelada, assim como um sistema dosimétrico constituído por um objeto simulador cúbico de 30x30x30 cm3 preenchido com água. Os valores obtidos da semente 6711 foram comparados com alguns apresentados na literatura, onde o parâmetro Constante de taxa de dose apresentou erro relativo em relação ao valor publicado no TG- 43 de 0,1%, sendo que os outros parâmetros analisados também apresentaram boa concordância com os valores publicados na literatura. Deste modo, pode-se considerar que os parâmetros utilizados nas simulações (espectro, modelagem geométrica e avaliação de resultados) estão compatíveis com outros estudos, sendo estes parâmetros também utilizados nas simulações da semente do IPEN. Considerando as análises de incerteza estatística, os valores obtidos da semente do IPEN são semelhantes aos valores da semente 6711. / Dissertação (Mestrado em Tecnologia Nuclear) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
|
50 |
Desenvolvimento e construção de sistema automatizados para controle de qualidade na produção de sementes de iodo-125 / Development and construction of an automated system for quality control in the iodine-125 seeds productionMOURA, JOAO A. 01 July 2016 (has links)
Submitted by Claudinei Pracidelli (cpracide@ipen.br) on 2016-07-01T11:08:37Z
No. of bitstreams: 0 / Made available in DSpace on 2016-07-01T11:08:37Z (GMT). No. of bitstreams: 0 / Tese (Doutorado em Tecnologia Nuclear) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
|
Page generated in 0.0537 seconds