Spelling suggestions: "subject:"slide."" "subject:"slice.""
1 |
A structured language for interactive graphicsTeeple, Douglas William Lloyd 05 1900 (has links)
This thesis discusses the design and implementation of the computer language SLING (Structured Language for Interactive Graphics). SLING by assign is a high-level structured procedural language. Constructs promoting user interaction have been added to enhance graphics capabilities. The implementation of SLING is core and execution-time efficient relative to current computer graphics languages. It is designed to run on a minicomputer with minimal core requirements. / Graduate and Postdoctoral Studies / Graduate
|
2 |
Utilização do biopolímero de cana-de-açúcar como novo material para sling pubo vaginal: análise estereológicaGonçalves de Lucena, Roberto January 2007 (has links)
Made available in DSpace on 2014-06-12T16:28:09Z (GMT). No. of bitstreams: 2
arquivo5639_1.pdf: 9621836 bytes, checksum: dce714d9966f8dda15c4d47fcb8bc106 (MD5)
license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5)
Previous issue date: 2007 / Introdução e Objetivos: O entendimento universal que os slings sub-uretrais representam o
padrão-ouro no tratamento da incontinência urinária feminina, leva a busca de um material
heterólogo adequado para esta finalidade. Um polissacarídeo extracelular obtido por síntese
a partir do melaço de cana-de-açúcar produzido no Laboratório de Microbiologia
Experimental da Universidade Federal Rural de Pernambuco. Depois de purificado, é um
produto transformado em uma película estável, sendo utilizado em diversos protocolos
desenvolvidos pelos grupos de pesquisa, os quais estão servindo de base para diversas
aplicações clínicas. O objetivo deste estudo é analisar os resultados da interação do
biopolímero com o hospedeiro, analisando a reação inflamatória causada pelo novo
material, utilizando a ferramenta da estereologia para sua quantificação e comparando com
material sintético de comportamento já conhecido. Materiais e Métodos: Foram utilizadas
40 (quarenta) ratas, variando de 200 a 300 gramas, que foram anestesiadas conforme
protocolo do núcleo de cirurgia experimental do Departamento de Cirurgia. Nos grupos A e
B, foi utilizado o sling de biopolímero e, nos grupos C e D, tela de prolene. O sacrifício foi
realizado após 30 e 90 dias. Após o sacrifício, a bexiga e uretra eram retiradas em bloco,
junto com a parede abdominal anterior, para que, após a fixação com formol 10%
tamponado, fossem realizadas secções com zona de interesse na região sub-uretral e
inserção do sling na parede abdominal. As lâminas foram coradas com hematoxilina
eosina e picro sirius. Resultados e conclusões: O material implantado mostrou-se
absolutamente inerte e preservado na região implantada. Não observamos alteração
morfológica ao nível da membrana de celulose, porém nas suas adjacências, vimos
discretas reação tipo corpo estranho, que foram encontradas eventualmente. Em algumas
áreas, observou-se processo de neovascularização, quando avaliado quantitativamente, e
verificou-se presença de maior quantidade de fibras colágenas na região sub uretral no
grupo que utilizou o sling de polímero. Na região sub aponeurótica, foi observada presença
de colágeno semelhante entre os grupos sem significância estatística. A membrana de
biopolímero mostrou-se no presente estudo, ser material estável, de fácil manipulação, com
reação tissular mínima, com boa incorporação ao hospedeiro. Ocorre maior reação
inflamatório na região sub uretral, porém sem causar erosão
|
3 |
Measuring Biomechanical Loads on the spine during Patient Lifting Sling Application and Removal: Assessing the effects of Work Method, Patient Weight and Bed HeightNagavarapu, Shasank January 2015 (has links)
No description available.
|
4 |
Active Space Debris Removal using Capture and EjectionMissel, Jonathan William 03 October 2013 (has links)
Low Earth Orbit is over-cluttered with rogue objects that threaten existing technological assets and interfere with allocating new ones. Traditional satellite missions are not efficient enough to collect an appreciable amount of debris due to the high cost of orbit transfers. Many alternate proposals are politically controversial, costly, or dependent on undeveloped technology. This dissertation attempts to solve the problem by introducing a new mission architecture, Space Sweeper, and bespoke hardware, Sling-Sat, that sequentially captures and ejects debris plastically. Resulting momentum exchanges are exploited to aid in subsequent orbit transfers, thus saving fuel. Sling-Sat is a spinning satellite that captures debris at the ends of adjustable-length arms. Arm length controls the angular rate to achieve a desired tangential ejection speed. Timing the release exacts the ejection angle. This process redirects debris to burn up in the atmosphere, or reduce its lifetime, by lowering its perigee.
This dissertation establishes feasibility of principles fundamental to the proposed concept. Hardware is conceptualized to accommodate Space Sweeper ’s specialized needs. Mathematical models are built for the purpose of analysis and simulation. A kinematic analysis investigates system demands and long-term behavior resulting from repeated debris interaction. A successful approach to enforce debris capture is established through optimal control techniques. A study of orbital parameters and their response to debris interactions builds an intuition for missions of this nature. Finally, a J2-compliant technique for path optimization is demonstrated. The results strongly support feasibility of the proposed mission.
|
5 |
Examining muscle activation for Hang Clean and three different TRX Power Exercises : A validation studyCarbonnier, Anders, Martinsson, Ninni January 2012 (has links)
Background: Resistance training has proven to increase athletic performance, traditionally barbell training and Olympic Lifting have been used for this purpose. Sling training has recently been developed as a complement or substitution to traditional resistance training. Research has shown an increase in sport specific athletic performance and core stability with sling training. TRX Suspension Trainer is a newly developed sling training tool and to date no independent research has been done with the TRX. Purpose: To examine and compare muscle activation using TRX and the Olympic Lifting movement Hang Clean. Methods: 32 senior high school male soccer players participated in the study. Surface electromyographic (sEMG) data were collected on mm.erector spinae (back), m.gluteus maximus (glutes), m.vastus lateralis (quadriceps), m.semitendinosus (hamstrings) and m.gastrocnemius caput laterale (calf). Surface EMG data was collected when the subjects performed five different exercises, Hang Clean, TRX Squat Jump, TRX Front Squat and TRX Power Pull. In addition a Squat Jump was used as reference. Results: A similar muscle activation was found between Hang Clean (674 µV), TRX Squat Jump (684 µV) and TRX Front Squat (691 µV). TRX Power Pull showed the highest activation for mm.erector spinae and m.gluteus maximus but the lowest when comparing total muscle activation for all measured muscles. Conclusion: The similar amount of muscular activation for Hang Clean, TRX Squat Jump and TRX Front Squat indicates that the TRX Suspension Trainer can be used as a complement, for experienced athletes, or a substitution, for novice athletes, to traditional strength training. Coaches and athletic trainers should acknowledge the need and the importance of resistance training for athletic performance.
|
6 |
Kom så bär jag dig : en studie om föräldrars upplevelse av att bära sitt barn medhjälp av bärdon / Come on, I'll carry you : A study about parents' experience of carrying their child with the help of a babycarrier or babysling.Lind, Emelie, Åsén, Emma January 2018 (has links)
Becoming a parent is a lifechanging event that can be demanding in todays' stressful living. Carrying babies with baby-carrier/baby-slings is becoming more and more acceptable in the society. To meet the requirements of promoting health and growth among children the nurse need greater understanding of parent's experiences of carrying their babies close with the help of a baby-carrier or baby-sling. The aim of this study was to exam parent's experience of carrying their child with the help of a baby-carrier or baby-sling. In this qualitative study eleven parents were interviewed with the help of a semi-structured question guide. Content analyse where used as a method and two themes emerged; Parent-perspective and Child-perspective. The parent's perception of using a baby-carrier or baby-sling was that it is a tool in everyday life as well as a good way to promote bonding and attachment. Parents need information about carrying babies with the help of a baby-carrier or baby-sling and desire it from healthcare professionals. The nurse specialist has a great responsibility in promoting good cooperation with parents and to promote health and growth for the children. It is therefore important that the nurse encourages parents to have their babies close. Using a baby-carrier or baby-sling is an easy tool that can help parents to have their baby close.
|
7 |
Equipamentos de autoajuda: projeto e validação de um protótipo funcional para sustentação e movimentação de membros superiores / Sling: design and functional prototype development applied to the apparatus for supporting and movement of the upper limbsBarbosa, Ismael Motta 04 February 2016 (has links)
O objetivo desse trabalho foi desenvolver um equipamento destinado a proporcionar a realização de exercícios terapêuticos, baseado numa abordagem sistemática de desenvolvimento de projeto orientado pelo usuário e obter um protótipo funcional. Por meio das técnicas de metodologia de projeto e dos fundamentos gerais de elementos de máquinas desenvolveram-se a fase do projeto conceitual, com interface ao projeto informacional de Souza (2016), e do projeto preliminar direcionado ao desenvolvimento de um protótipo funcional destinado à sustentação e movimentação dos membros superiores de indivíduos com disfunções motoras nos nestes membros. Devido a um conjunto de fatores provenientes dos mais diversos segmentos da sociedade, há uma demanda crescente com relação à atuação das diversas áreas da engenharia, que possam fornecer soluções tecnicamente viáveis e ainda, com um grau de personalização em massa destinadas às aplicações na área da saúde. A área de conhecimento denominada \"Tecnologia Assistiva\" (TA) inserida na área da saúde, atua principalmente no desenvolvimento de órteses, próteses e auxílio à mobilidade, desenhando fronteiras com questões de acessibilidade, com uso e adequação de produtos, bem como na atuação de áreas de habilitação e reabilitação promovendo qualidade de vida e inclusão social de indivíduos com algum tipo de deficiência ou mobilidade reduzida. Nesse trabalho, o uso de ferramentas de metodologia de projeto durante as discussões sobre o projeto informacional e a implementação do projeto conceitual, ambos de caráter interdisciplinar, permitiu estabelecer a interface entre decisões técnicas de engenharia e os requisitos do usuário. O usuário intermediário, responsável pela prescrição e avaliação do protótipo foi representado por uma amostra de terapeutas ocupacionais, que acompanharam o processo de desenvolvimento do projeto até a validação do protótipo funcional. Os resultados obtidos nesse trabalho foram: obtenção de uma lista de requisitos do usuário, que convertida em um conjunto de características técnicas permitiu o desenvolvimento do projeto orientado pelo usuário (Terapeutas Ocupacionais) e construção de um protótipo funcional. O equipamento de apoio aos exercícios terapêuticos proposto apresenta graus de inovação, quando comparado à equipamentos comerciais e patentes, principalmente: adequação à diferentes mobiliários em ambiente hospitalar e doméstico (camas, cadeiras, mesas); melhor processo de compactação do equipamento para armazenagem e transporte, feito por uma única pessoa; exercícios com os membros superiores: uni e bilateral e abertura completa dos membros superior no plano coronal por meio de guias lineares. / This work presented the development of an apparatus whose objective is allow the therapeutic exercises, based on a systematic approach user-oriented design development, and fabricate a functional prototype. Based on design methodology and machine elements theory it was developed the conceptual and the preliminary design phase, based on the informational design phase of Souza (2016), to develop a functional prototype aimed to provide support and movement of the upper limbs of people with motor dysfunction in these members. Due to a range of factors from the various segments of society, there is increasing demand related to the performance of various areas of engineering, that can provide technically feasible solutions and with a degree of mass customization intended for applications in the health area. The knowledge area of \"Assistive Technology\" (AT) is inserted in the health area and acts mainly in the development of prostheses, orthoses and aid mobility, by drawing borders with accessibility issues, using and adjusting products, in addition to acting in habilitation and rehabilitation areas, which promote quality of life and social inclusion of individuals with a disability or reduced mobility. In this work, the use of design methodology tools during the discussion on the informational design and implementation of conceptual design, both interdisciplinary, revealed the interface between technical engineering decisions and user requirements. The intermediate user, responsible for evaluating the prototype was represented by sample occupational therapists, which prescribes and follows up the use of the mechanisms and/or equipment to end users. The main result of this work was a better definition of the user requirements that allowed obtaining design parameters focusing on occupational therapists as well as the development of a functional prototype. The main technical characteristics obtained through of the interactive and iterative processes along the informational, conceptual and preliminary design phases both prototype validation were: compaction of the device (related to storage and use for one or both arms of the user). Besides, the equipment allows possibility of adaptation to different furniture and environments: hospital, clinics, small treatment rooms, domestic bed, and chairs and use; rehabilitation exercises with positions of the upper limbs: uni- and bilateral and total movement of the upper limbs on coronal plane based on linear guides.
|
8 |
TÉCNICA DE SLING: AVALIAÇÃO DOS RESULTADOS COMPARANDO FAIXA DE POLIPROPILENO INDUSTRIALIZADA E ARTESANAL / TECHNIQUE OF SLING: EVALUATION OF RESULTS COMPARE POLYPROPYLENE RANGE INDUSTRIALIZED AND CRAFTSSousa, Antonio de Pádua Silva 19 October 2008 (has links)
Made available in DSpace on 2016-08-19T18:15:57Z (GMT). No. of bitstreams: 1
Antonio de Padua Silva Sousa.pdf: 602887 bytes, checksum: 1f45f76bbf02c47503de434a107e22e5 (MD5)
Previous issue date: 2008-10-19 / This study proposes to evaluate the results post stress urinary incontinence surgery (SUI)
using the Sling technique and utilizing a range of polypropylene sub urethral manually
manufactured (Marlex®), and laboratory made (Advantage®), comparing the results in
both groups and prostheses costs. The sample used was of 39 women carriers of SUI
resulting from hyper mobility of the bladder neck and/or sphincteric incompetence
determined by clinical evaluation and urodynamic studies. The criterion considered was
the exclusion of diabetes mellitus, previous extended pelvic surgeries and previous
radiotherapy. The patients were split in 2 groups. Group 1 Patients from the department
of Urology at the University Hospital of the Federal University of Maranhao (19 patients)
and Group 2 Patients from private clinics (20 patients). Group 1 used the manually
manufactured polypropylene sub urethral while group 2 used the laboratory made. Patients
were evaluated in between thirty, sixty and ninety days post surgery comparing the
following variables: Average surgery time, hospitalization time, difficulty to urinate,
length of time using the post surgery probe, normalization of urinary jet, involuntary urine
loss, level of satisfaction regarding the surgery, urodynamic alterations and probe costs.
The average surgery time was of 43 25 in Group 1 and 51 42 Group 2. As to difficulty to
urinate post surgery, in Group I, one hundred percent (100%) of the patients presented no
difficulties while in Group 2; ninety four point seven percent (94.7%) were able to urinate
properly. Regarding the probe use one hundred percent (100%) of the patients from both
groups were free from it by the end of this study. All patients from both groups presented
normal urinary jet during the last evaluation. In Group 1 one hundred percent (100%) of
the patients did not accuse urine loss, while in Group 2 it was ninety four point seven
percent (94.7%) at the ninetieth day. The level of satisfaction was of one hundred percent
(100%) of the patients from Group 1 while one patient in Group 2 considered the surgery
unsuccessful. The evaluation urodynamic presented non inhibit contraction of low vesical
pressure in eleven point one percent (11.1%) in Group 1 and ten point five percent (10.5%)
in Group 2. There were no complications in both groups. Occurrences observed: burning
micturition and urinary urgency spontaneously disappeared by the end of this study and did
not have any relations with sub urethral meshes. We can conclude the use of polypropylene
mesh (Marlex ®) manually manufactured can also be used in Sling surgeries, saving on
resources and having similar results to the use of the laboratory made version. / Este trabalho se propõe avaliar os resultados pós-operatórios da cirurgia de incontinência
urinária de esforço (IUE), pela técnica de Sling, utilizando-se faixa de polipropileno
suburetral de fabricação artesanal (Marlex®) e industrializada (Advantage®). comparando
os resultados em ambos os grupos e o custo das próteses. A amostra foi de 39 mulheres
portadoras de IUE resultante de hipermobilidade do colo vesical e/ou incompetência
esfincteriana feita pela avaliação clinica e estudo urodinamico. Foram considerados critério
de não inclusão diabetes mellitus, passado de cirurgias pélvicas ampliadas e radioterapia
prévia. As pacientes foram dividas em grupos: Grupo I oriundas do Serviço de Urologia do
Hospital Universitário da Universidade Federal do Maranhão (19 pacientes) e Grupo II
pacientes provenientes da Clinica Privada (20 pacientes). No Grupo I, utilizou-se tela
artesanal e no Grupo II, tela industrializada. As pacientes foram avaliadas com trinta,
sessenta e noventa dias de pós-operatório comparando-se as seguintes variáveis: tempo
médio de cirurgia,tempo de internação, dificuldade para urinar, tempo de permanência de
sonda no pós-operatório, normalização do jato urinário, perda urinária involuntária, grau de
satisfação em relação à cirurgia, alteração urodinâmica e custo das próteses. O tempo
médio de cirurgia foi de 43 25 no Grupo I e 51 42 no Grupo II. O tempo médio de
internação foi de 52hs8min horas no Grupo I e de 49hs14min no grupo II. Quanto à
dificuldade de urinar no pós-operatório, no Grupo I, 100% das pacientes nada referiam no
final da observação e no Grupo II, 94,7% urinavam bem. No que concerne ao uso de
sonda, em ambos os grupos, 100% das pacientes estavam livre desta ao fim da observação.
Todas as pacientes de ambos os grupos apresentavam jato urinário normal na ultima
avaliação. No Grupo I, 100% das pacientes não referiam perda urinária e no Grupo II
94,7% no 90º dia pós-operatório. O grau de satisfação foi de 100% nas pacientes do Grupo
I, enquanto no Grupo II uma paciente referiu insucesso. A avaliação urodinâmica
demonstrou Contração Não Inibida (CNI) de baixa pressão em 11,1% no Grupo I e em
10,5% no Grupo II. Não houve complicação importante em ambos os grupos. As
intercorrências observadas: ardência miccional e urgência urinária desapareceram
espontaneamente ao final da observação não tinham relação com o material das faixa
suburetrais.Conclui-se que a utilização de alça de polipropileno (Marlex ®) de fabricação
artesanal pode de ser utilizada nas cirurgias de Sling, com economia de recursos e com
resultados semelhantes àqueles observados com a utilização das alças industrializadas.
|
9 |
Desenvolvimento de tela transobturatória polimérica para uso na técnica de sling.COUTINHO, Carmem Lúcia Cavalcanti. 14 June 2018 (has links)
Submitted by Emanuel Varela Cardoso (emanuel.varela@ufcg.edu.br) on 2018-06-14T20:51:37Z
No. of bitstreams: 1
CARMEM LÚCIA CAVALCANTI COUTINHO – DISSERTAÇÃO (PPG-CEMat) 2015.pdf: 1178536 bytes, checksum: 7b4bc6d75aa15e3438cedfa584239124 (MD5) / Made available in DSpace on 2018-06-14T20:51:37Z (GMT). No. of bitstreams: 1
CARMEM LÚCIA CAVALCANTI COUTINHO – DISSERTAÇÃO (PPG-CEMat) 2015.pdf: 1178536 bytes, checksum: 7b4bc6d75aa15e3438cedfa584239124 (MD5)
Previous issue date: 2015-07-09 / A técnica sling pela via transobturadora é eficaz para o tratamento de mulheres com
Incontinência Urinária de Esforço e apresenta elevada taxa de cura e melhora da
qualidade de vida com baixos índices de complicações. Este trabalho teve como
objetivo desenvolver e confeccionar, uma tela de policaprolactona, para uso na
técnica de Sling e realizar análises comparativas deste material com a tela de
polipropileno, utilizada comercialmente. A pesquisa foi desenvolvida no Laboratório
de Avaliação e Desenvolvimento de Biomateriais do Nordeste – CERTBIO. Utilizouse duas amostras de tela, uma confeccionada no CERTBIO e outra de uso
comercial. Foram avaliadas as composições químicas e físicas das telas de
Policaprolactona (PCL) e Polipropile no (PP), através das técnicas de:
Espectroscopia na Região de Infravermelho com Transformada de Fourier (FTIR),
Difração de Raios X (DRX) e Microscopia Eletrônica de Varredura (MEV), Tensão
superficial, Ensaios Mecânicos de Tração e Teste de Citotoxicidade. Pode-se
comprovar pela análise de FTIR, que o material formador das telas era apenas de
polipropileno e policaprolactona. A análise de DRX corroborou com os resultados
obtidos na análise de FTIR, que indicavam que o material das telas tratava de PP e
PCL, apresentando um espectograma característico d estes polímeros. Também,
através da análise de DRX, foi possível observar o grau de cristalinidade indicando o
PP que possui maior grau de cristalinidade que o PCL. Pode-se comprovar também,
que o PP possui maior resistência mecânica que o PCL, verificando assim que o PP
é mais frágil e quebradiço do que o PCL. A análise de tensão superficial mostrou
que as duas telas possuem molhabilidade parcial devido as cavidade presentes na
superfície das telas. A biocompatibilidade dos compostos foi confirmada com o teste
de Citotoxicidade. / The sling technique by transobturator approach is effective for the treatment of
women with Stress Urinary Incontinence and has a high cure rate and improved
quality of life with low complication rates. This work aimed to develop and produce,
polycaprolactone, screen for use in Sling surgery and to perform comparative
analyses of this material with a polypropylene bladder, used commercially. The
survey was developed in the laboratory of evaluation and development of
Biomaterials in the Northeast-CERTBIO. Two samples were used to screen; a made
in the laboratory and another used commercially. Been evaluated physical and
chemical compositions of the Polycaprolactone (PCL) and Polypropylene (PP)
screens, through the following techniques: infrared Spectroscopy in the region with a
Fourier transform (FTIR), x-ray Diffraction (XRD) and scanning electron microscopy
(SEM), surface tension, traction mechanical essays and Cytotoxicity test. You can
check by the FTIR analysis, that the trainer material of fabrics was just poliproplieno
and polycaprolactone, for examining the computer spectrogram. The XRD analysis
corroborated with the results obtained in the FTIR analysis, which indicated that the
material was PP screens and PCL, showing a characteristic you might like to look of
these polymers. Also, through the analysis of DRX, it was possible to o bserve the
degree of crystallinity indicating the PP has higher degree of crystallinity the PCL.
One can prove that the PP has higher mechanical strength than the PCL, checking
so that the PP is more brittle than the PCL. The analysis of surface tension showed
that both screens have partial wettability due to cavity present on the surface of the
canvas. The biocompatibility of the compounds has been confirmed with the
Cytotoxicity test and it showed low cytotoxicity in two screens.
|
10 |
Equipamentos de autoajuda: projeto e validação de um protótipo funcional para sustentação e movimentação de membros superiores / Sling: design and functional prototype development applied to the apparatus for supporting and movement of the upper limbsIsmael Motta Barbosa 04 February 2016 (has links)
O objetivo desse trabalho foi desenvolver um equipamento destinado a proporcionar a realização de exercícios terapêuticos, baseado numa abordagem sistemática de desenvolvimento de projeto orientado pelo usuário e obter um protótipo funcional. Por meio das técnicas de metodologia de projeto e dos fundamentos gerais de elementos de máquinas desenvolveram-se a fase do projeto conceitual, com interface ao projeto informacional de Souza (2016), e do projeto preliminar direcionado ao desenvolvimento de um protótipo funcional destinado à sustentação e movimentação dos membros superiores de indivíduos com disfunções motoras nos nestes membros. Devido a um conjunto de fatores provenientes dos mais diversos segmentos da sociedade, há uma demanda crescente com relação à atuação das diversas áreas da engenharia, que possam fornecer soluções tecnicamente viáveis e ainda, com um grau de personalização em massa destinadas às aplicações na área da saúde. A área de conhecimento denominada \"Tecnologia Assistiva\" (TA) inserida na área da saúde, atua principalmente no desenvolvimento de órteses, próteses e auxílio à mobilidade, desenhando fronteiras com questões de acessibilidade, com uso e adequação de produtos, bem como na atuação de áreas de habilitação e reabilitação promovendo qualidade de vida e inclusão social de indivíduos com algum tipo de deficiência ou mobilidade reduzida. Nesse trabalho, o uso de ferramentas de metodologia de projeto durante as discussões sobre o projeto informacional e a implementação do projeto conceitual, ambos de caráter interdisciplinar, permitiu estabelecer a interface entre decisões técnicas de engenharia e os requisitos do usuário. O usuário intermediário, responsável pela prescrição e avaliação do protótipo foi representado por uma amostra de terapeutas ocupacionais, que acompanharam o processo de desenvolvimento do projeto até a validação do protótipo funcional. Os resultados obtidos nesse trabalho foram: obtenção de uma lista de requisitos do usuário, que convertida em um conjunto de características técnicas permitiu o desenvolvimento do projeto orientado pelo usuário (Terapeutas Ocupacionais) e construção de um protótipo funcional. O equipamento de apoio aos exercícios terapêuticos proposto apresenta graus de inovação, quando comparado à equipamentos comerciais e patentes, principalmente: adequação à diferentes mobiliários em ambiente hospitalar e doméstico (camas, cadeiras, mesas); melhor processo de compactação do equipamento para armazenagem e transporte, feito por uma única pessoa; exercícios com os membros superiores: uni e bilateral e abertura completa dos membros superior no plano coronal por meio de guias lineares. / This work presented the development of an apparatus whose objective is allow the therapeutic exercises, based on a systematic approach user-oriented design development, and fabricate a functional prototype. Based on design methodology and machine elements theory it was developed the conceptual and the preliminary design phase, based on the informational design phase of Souza (2016), to develop a functional prototype aimed to provide support and movement of the upper limbs of people with motor dysfunction in these members. Due to a range of factors from the various segments of society, there is increasing demand related to the performance of various areas of engineering, that can provide technically feasible solutions and with a degree of mass customization intended for applications in the health area. The knowledge area of \"Assistive Technology\" (AT) is inserted in the health area and acts mainly in the development of prostheses, orthoses and aid mobility, by drawing borders with accessibility issues, using and adjusting products, in addition to acting in habilitation and rehabilitation areas, which promote quality of life and social inclusion of individuals with a disability or reduced mobility. In this work, the use of design methodology tools during the discussion on the informational design and implementation of conceptual design, both interdisciplinary, revealed the interface between technical engineering decisions and user requirements. The intermediate user, responsible for evaluating the prototype was represented by sample occupational therapists, which prescribes and follows up the use of the mechanisms and/or equipment to end users. The main result of this work was a better definition of the user requirements that allowed obtaining design parameters focusing on occupational therapists as well as the development of a functional prototype. The main technical characteristics obtained through of the interactive and iterative processes along the informational, conceptual and preliminary design phases both prototype validation were: compaction of the device (related to storage and use for one or both arms of the user). Besides, the equipment allows possibility of adaptation to different furniture and environments: hospital, clinics, small treatment rooms, domestic bed, and chairs and use; rehabilitation exercises with positions of the upper limbs: uni- and bilateral and total movement of the upper limbs on coronal plane based on linear guides.
|
Page generated in 0.0773 seconds