• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 24
  • 17
  • 7
  • 4
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 64
  • 64
  • 33
  • 22
  • 16
  • 15
  • 12
  • 11
  • 8
  • 8
  • 8
  • 8
  • 7
  • 7
  • 6
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
61

Klimat- och kostnadseffektivakontorsbyggnader : En fallstudie av ett flervåningshus / Climate and cost-effective office buildings : A case study of a multi-storey building

Johansson, Anders, Åström, Karl January 2023 (has links)
Syftet med denna studie var att undersöka klimat- och kostnadseffektiva lösningar för att minska kontorsbyggnaders påverkan på miljön. Byggnader står för en betydande del av Sveriges klimatpåverkan och kostnader, det finns därav behov av att hitta sätt att reducera den påverkan. Teorin som låg till grund för studien var livscykelanalys och livscykelkostnad, som tar hänsyn till klimatpåverkan och kostnader genom hela byggnadens livscykel. Metoden som användes var litteraturstudie, där tidigare forskning och studier analyserades. Diskussion fördes även med sakkunniga personer inom ämnet för att identifiera lösningar för att minska klimatpåverkan och kostnader i byggnader. En hypotetisk fallstudiebyggnad skapades där klimat- och kostnadseffektiva åtgärder implementerades. Genom att titta på byggnadsdelarna stomme, klimatskal, isolering och dess inverkan på energianvändning i en kontorsbyggnad identifierades olika åtgärder som kunde minska klimatpåverkan och kostnader. Dessa inkluderar användning av återvunnet material och minskad energiförbrukning genom förbättrade isoleringsegenskaper. Ytterligare undersöktes val av material och teknik vilket anses hållbara och energieffektiva. Resultatet visar att byggnadsmaterialen har störst påverkan på klimat och kostnaden under Produkt- och Byggproduktionsskedet, medan energiförbrukningen har störst påverkan under skedet Driftenergi i Användningsskedet. De klimatåtgärder som framstår som mest framstående och optimala lösningar för vår fallstudiebyggnad inkluderar användningen av kostnadseffektiva solceller på taket (Åtgärd 7), isolering av ytterväggarna med PIR-isolering (Åtgärd 5), tilläggsisolering av ytterväggarna med EPS-isolering (Åtgärd 3) samt minskat materialspill på byggarbetsplatsen med 25%. Dessa lösningar visar sig inte bara ha en betydligt lägre klimatpåverkan, utan även en mer fördelaktig kostnadseffektivitet över hela livscykeln för fallstudiebyggnaden. / The purpose of this study was to investigate climate and cost-effective solutions to reduce the environmental impact of office buildings. Buildings account for a significant portion of Sweden's climate impact and costs, and there is a need to find ways to reduce this impact. The theoretical framework underlying the report was life cycle analysis and life cycle cost, which consider the climate impact and costs throughout the building's life cycle. The method used was a document study, where previous research and studies were analyzed. A hypothetical case study building was created, where climate- and cost-effective measures were implemented. By examining the building components such as the structure, envelope, insulation, and their impact on energy consumption in an office building, various measures were identified to reduce climate impact and costs. Additionally, the selection of sustainable and energy-efficient materials and technologies was investigated. The results show that building materials have the greatest impact on the environment and cost during the Production and Installation stages, while energy consumption has the greatest impact during the Operational energy use module in the Use stage. The climate measures that stand out as optimal solutions include the use of cost-effective solar panels on the roof (Measure 7), insulating the outer walls with PIR insulation (Measure 5), additional insulation of the outer walls with EPS insulation (Measure 3), and reducing material waste at the construction site by 25%. These solutions not only demonstrate significantly lower climate impact but also exhibit a more advantageous cost-effectiveness over the entire lifecycle.
62

Optimization Study of a Combined Wind-Solar Farm for a Specified Demand

Rama, Venkat Siddhartha 05 August 2020 (has links)
No description available.
63

Thermal Snail : Design and Performance Evaluation of a Non-Electronic Autonomous Vehiclefor Harnessing Thermal Expansion of Volatile Fluid for Movement

Chen, Xin, Velin, Benjamin January 2024 (has links)
No description available.
64

Porovnání výkonnosti fotovoltaických panelů v podmínkách ČR / Comparison of different photovoltaic panels in CR

Červinka, Pavel January 2011 (has links)
This term paper deals about history, principle and use of photovoltaic panel. It describes their stucture and constantly improving properties of these panels. It outlines their gradual generational evolution from beginning to present. Then it describes the various systems involved on – grid and off – grid. It also describes and compares the photovoltaic panels and inverters from different global manufacturer. The end of this work deals about conditions of photovoltaic in the Czech republic and about Hady photovoltaic incubator, which belongs to the company Energ servis a.s. It presents a comparison of different local and the analysis of the impact of shading for the achievement of the photovoltaic panel. It makes mathematic models for calculation of the spacing range and calculation the power loss in a specific shade.

Page generated in 0.0731 seconds