• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 415
  • 126
  • 39
  • Tagged with
  • 568
  • 568
  • 369
  • 360
  • 101
  • 100
  • 91
  • 82
  • 72
  • 70
  • 70
  • 67
  • 59
  • 55
  • 50
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Caractérisation par spectrométrie de masse d'extraits de millepertuis potentiellement utilisables en photodiagnostic et photothérapie des cancers : étude de leurs propriétés photochimiques en solution et en milieu cellulaire / Mass spectrometric characterization of saint John's wort extracts potentially suitable for cancers photodiagnostic and phototherapy : study of their photochemistry in organic solvent and cellular medium

Hecka, Audrey 20 March 2009 (has links)
La thérapie photodynamique (PDT) associe la lumière à un agent photosensibilisateur, qui dans l’idéal se localise spécifiquement dans les tissus cancéreux. Illuminé dans le visible, ce photosensibilisateur génère de l’oxygène moléculaire singulet (1O2) et des espèces radicalaires toxiques pour les cellules. Sa fluorescence peut également servir à diagnostiquer les lésions néoplasiques : il s’agit du photodiagnostic (PDD). Les extraits de Millepertuis, connus pour leur activité antidépressive, contiennent également des composés photoactifs, dont l’hypéricine, objet de nombreux travaux dans le cadre de la PDT et du PDD. Cependant, son coût de production est élevé et son utilisation limitée par un manque de solubilité en milieu physiologique. Dans ce contexte, la présente étude vise à évaluer le potentiel des extraits de Millepertuis pour la PDT et le PDD. Le matériel végétal utilisé a dans un premier temps fait l’objet d’analyses par Spectrométrie de Masse (SM) in situ afin de caractériser les molécules photoactives au niveau même des structures végétales impliquées dans leur production. Ces composés ont ensuite été extraits par un solvant organique, et ce mélange a fait l’objet d’études photochimiques visant à quantifier sa production d’1O2 sous illumination laser. La composition des extraits a ensuite été étudiée par désorption/Ionisation Laser couplée à la SM (TOF et FTICR), et par Ionisation Electropray couplée à la FTICRMS. Puis, ils ont fait l’objet d’études en milieu cellulaire (cancer de la vessie), visant à déterminer leur cytotoxicité à l’obscurité, les cinétiques d’internalisation des composés photoactifs, leur phototoxicité et la nature des composés internalisés / Photodynamic therapy (PDT) combines light with a drug called photosensitizing agent, which preferentially accumulates in cancerous cells. Irradiated with visible light, this photosensitizing agent generates singlet oxygen (1O2) and radicals that demonstrate cell toxicity. Fluorescence of this drug also allows diagnosing neoplasic lesions: this is photodynamic diagnosis (PDD).St John’s Wort extracts, mainly known for their antidepressant activity, also contain photoactive compounds, including hypericin which has been extensively studied for PDT and PDD. However, producing this molecule in large amounts is expensive and its use is restricted by a poor solubility in physiological medium. In this context, the present study deals with determining in what extent St John’s Wort extracts could be useful for PDT and PDD. Flowers that were used in this work were firstly in situ-analyzed by mass spectrometry in order to characterized photoactive compounds at the level of structures involved in their biosynthesis. These compounds were then extracted by organic solvent and the resulting mixture subjected to singlet oxygen production measurements under laser illumination. Qualitative analysis of the extracts was then performed either by Laser Desorption/Ionization or Electrospray Ionization coupled with Mass Spectrometry (TOF and FTICR). Finally, their behavior in cellular medium (bladder cancer) was investigated in terms of dark cytotoxicity, intracellular accumulation of photoactive compounds, phototoxicity and characterization of compounds absorbed by cells
12

Methodological developments based on mass spectrometry for the analysis of glycoproteins and polysaccharides of plant gums : an application to cultural heritage samples / Développements méthodologiques basés sur la spectrométrie de masse pour l’analyse des glycoprotéines et polysaccharides des gommes végétales : application aux échantillons du patrimoine culturel

Granzotto, Clara 18 December 2014 (has links)
L’analyse d’échantillons du Patrimoine Culturel est primordiale pour la compréhension des techniques, la conservation des œuvres et leur restauration. Ces échantillons sont rares et précieux et l’analyse doit être effectuée sur une faible quantité de matière, ce qui nécessite le développement et l’optimisation de méthodes analytiques appropriées. L’objectif de ce travail de thèse a donc été de développer de nouvelles méthodes analytiques dans le but d’étudier les glycoprotéines et les polysaccharides de gommes végétales des échantillons du Patrimoine Culturel. Les macromolécules ont été séparées par chromatographie d'exclusion stérique et électrophorèse sur gel de polyacrylamide modifié, révélant la présence de poids moléculaires très élevés pouvant atteindre jusqu’à 1 à 2 millions de Dalton. Une stratégie analytique innovante basée sur la spectrométrie de masse a permis d’obtenir des empreintes caractéristiques de chaques gommes. La stratégie analytique développée a été appliquée avec succès sur un échantillon d'aquarelle daté de 1870 du Metropolitan Museum of Art (New York, USA). / The analysis of Cultural Heritage samples is critical for the understanding of the arstists' technique, the conservation and restoration of artworks. These objects under investigation are rare and precious and the amount of sample available for the analysis is usually very low, thus implying the development and the optimization of adapted analytical methodologies. The objective of this PhD was to develop new analytical methods to study glycoproteins and polysaccharides from plant gums in Cultural Heritage samples.These macromolecules have been separated by size exclusion chromatography and modified polyacrylamide gels, which allowed to reveal the presence of proteins with molecular weights up to 1-2 million Dalton. A novel analytical strategy based on mass spectrometry allowed to obtain the caracteristic fingerprint of each plant gum. This developed method was successfully applied on a watercolor sample dated from 1870 supplied by the Metropolitan Museum of Art (New York, USA).
13

Characterization of soot particles and their precursors produced during the combustion of conventional and alternative fuels : an in-situ laser diagnostics and ex-situ mass spectrometry investigation / Caractérisation des particules de suie et de leurs précurseurs produits lors de la combustion de carburants fossiles et alternatifs : une étude in situ par diagnostics laser et ex situ par spectrométrie de masse

Ngo, Thi Linh Dan 10 October 2019 (has links)
L'intérêt pour les biocarburants s’est considérablement accru ces dernières années car ceux-ci pourraient permettre de diminuer la dépendance aux combustibles fossiles et contribuer à une croissance neutre en carbone. L’influence de l’utilisation de biocarburants sur les émissions de polluants (CO,CO_2,NO_x,HC, etc.) a fait l’objet de nombreux travaux, cependant les effets de la nature de ces carburants alternatifs sur les propriétés physico-chimiques des particules et des espèces aromatiques produites sont encore peu étudiés. Dans le cadre de ce travail de thèse, nous visons à caractériser les émissions de particules de suie et d'hydrocarbures aromatiques polycycliques (HAP) lors de la combustion de carburants conventionnels et alternatifs (biocarburants) pertinents pour les secteurs de l'automobile et de l'aéronautique, tout en essayant de mettre en lumière leurs influence sur les mécanismes de formation de ces polluants. Pour atteindre cet objectif, deux réacteurs de laboratoire, un bruleur turbulent swirlé et un Combustion Aerosol STandard (CAST), ont été utilisés comme générateurs de suie. De plus, nous avons combiné différentes techniques laser complémentaires in situ, les incandescence et fluorescence induites par laser (LII/LIF), et ex situ, la spectrométrie de masse après désorption et ionisation laser (L2MS) et la spectrométrie de masse des ions secondaires (SIMS). Dans une flamme turbulente swirlée pour cinq carburants (Diesel, n-butanol, mélange 50/50 Diesel/n-butanol, Jet A1 et Synthetic Paraffinic Kerosene SPK), les profils LII et LIF et les propriétés des particules de suie et de leurs précurseurs en fonction de la hauteur dans la flamme ainsi que leur composition chimique ont été étudiés. De fortes corrélations entre les résultats obtenus avec les techniques in situ et ex situ ont été mises en évidence permettant de caractériser spectralement et chimiquement ces espèces. En outre, une nouvelle méthode d'étalonnage a été développée pour déduire directement la fraction volumique de suie à partir du signal LII en utilisant la luminance énergétique absolue émise par une source ayant un rayonnement de corps noir. En parallèle, les expériences utilisant le dispositif CAST ont été menées avec les carburants aéronautiques (Jet A1 et SPK). Outre l'influence du carburant de substitution, les effets d’un stripper catalytique (CS) sur les particules de suie et les espèces volatiles ont été examinés. / Interest in biofuels has increased significantly in recent years as they could reduce dependence on fossil fuels and contribute to carbon-neutral growth. The influence of using biofuels on their exhaust emissions (CO,CO_2,NO_x,HC, etc.) has been studied widely. However, the effects of the nature of these alternative fuels on the physical and chemical properties of the particles and aromatic species produced are not fully understood. As part of this thesis work, we aim to study the emissions of soot particles and polycyclic aromatic hydrocarbons (PAHs) during the combustion of conventional and alternative fuels (biofuels) relevant to the automotive and aerospace sectors, while trying to highlight their influence on the formation of such pollutants. To achieve this goal, two laboratory combustors, a swirled turbulent jet burner and a Combustion Aerosol STandard (CAST), were used as soot generators. In addition, we have combined various complementary in-situ laser techniques, laser-induced incandescence and fluorescence (LII/LIF), and ex-situ two-step laser mass spectrometry (L2MS) and secondary ion mass spectrometry (SIMS). In a swirled turbulent jet flame for five fuels (Diesel, n-butanol, 50/50 Diesel/n-butanol mixture, Jet A1 and Synthetic Paraffinic Kerosene SPK), the LII and LIF profiles and properties of soot particles and their precursors with the height in the flame as well as their chemical composition were studied. Strong correlations between the results obtained with in-situ and ex-situ techniques have been demonstrated which allowed us to characterize these species spectrally and chemically. In addition, a new calibration method has been developed to directly deduce the soot volume fraction from the LII signal using the absolute radiance emitted from a light source having black body behavior. In parallel, experiments using the CAST device were conducted with aeronautical fuels (Jet A1 and SPK). In addition to the influence of the alternative fuel, the effects of a catalytic stripper (CS) on soot particles and volatile species were examined.
14

Interprétation automatisée des spectres de masse de protéines obtenus par ionisation Electrospray

Ethier, Martin January 2001 (has links)
Mémoire numérisé par la Direction des bibliothèques de l'Université de Montréal.
15

An investigation of the factors affecting the isotopic peak ratios of peptides measured by fast atom bombardment mass spectrometry

Visentini, Giuseppina January 1989 (has links)
Mémoire numérisé par la Direction des bibliothèques de l'Université de Montréal.
16

LA METHODE DIAMS : Desorption/Ionization on self-Assembled Monolayer Surface Une nouvelle technique de désorption ionisation laser sans matrice pour la Spectrométrie de Masse

Bounichou, Matthieu 21 May 2010 (has links) (PDF)
Une nouvelle méthode appelée DIAMS (Desorption/Ionization on self-Assembled Monolayer Surface) a été développée pour remédier aux problèmes liés à la présence d'ions de matrice en ionisation MALDI (Matrix Assisted Laser Desorption/Ionization). Le principe de la méthode DIAMS est d'obtenir des spectres de masse à partir d'échantillons de faible poids moléculaire directement déposés sur une surface d'or recouverte d'une monocouche organique auto-assemblée (SAM) absorbant à la longueur d'onde du laser (337 nm). Après un rappel sur l'interaction laser/matière en spectrométrie de masse, l'élaboration des cibles DIAMS et leur contrôle par électrochimie sont décrits. La faisabilité de la méthode et sa robustesse sont testées à partir de l'analyse de lipides. Les résultats sont comparés avec d'autres méthodes telles que le LDI sur surface d'or et le MALDI. Une étude mécanistique est ensuite initiée pour apporter des éléments de compréhension au processus DIAMS. Il s'agit de comparer les évaluations de distributions d'énergie interne P(Eint) des ions produits en DIAMS et LDI sur or. Dans ce but, des molécules thermomètres telles que des sels de benzylpyridinium substitués et des peptides modèles sont utilisées. Les P(Eint) sont déterminées par la méthode de rendement de survie d'ions et confirmées à l'aide du logiciel MassKinetics. Ainsi, pour une certaine fluence du laser, la distribution d'énergie interne est purement thermique en DIAMS, contrairement à ce qui est mesuré en LDI sur surface d'or. La présence d'un groupement chromophore au sein de la monocouche (bithiophène), constitue un milieu protecteur vis-à-vis du rayonnement laser; cette protection semble augmenter avec la fluence laser. Enfin, une mesure des vitesses initiales des ions de la gramicidine désorbés en DIAMS et LDI sur or, révèle que la nature de la surface n'a pas d'influence sur l'énergie cinétique initiale des ions produits par désorption/ionisation laser.
17

Développement de l'approche métabolomique par couplage chromatographie liquide / spectrométrie de masse : application à la nutrition

Pereira, Hélène 01 February 2010 (has links) (PDF)
L'étude du métabolome est un challenge analytique important, de part la grande diversité chimique des métabolites présents à des concentrations très variables dans les matrices biologiques. Ce travail présente une stratégie analytique mettant en oeuvre le couplage chromatographie liquide / spectrométrie de masse afin d'acquérir des profils métaboliques de fluides biologiques et d'identifier des biomarqueurs potentiels de dysfonctionnements métaboliques. Une attention particulière a été donnée à l'étude des sources de variablité analytique, depuis l'étape de préparations d'échantillons jusqu'au traitement des données. Un protocole optimisé a été proposé et appliqué à une intervention nutrionnelle (ANR METAPROFILE). L'identification a été basée sur l'utilisation des bases de données, ainsi que sur l'interprétation des informations spectrales (profils isotopiques et fragmentations MSn)
18

Évaluation de différentes composantes chromatographiques d'un système nano-LC-MS pour des applications protéomiques

Forest, Anik January 2006 (has links)
Mémoire numérisé par la Direction des bibliothèques de l'Université de Montréal.
19

Analyse des composantes de la propolis par GC-MAB/MS

Simon, Marilyn January 2005 (has links)
Mémoire numérisé par la Direction des bibliothèques de l'Université de Montréal.
20

Potentialités d'utilisation du nez électronique à spectromètre de masse pour la caractérisation de la fraction volatile du liège oenologique

Boudaoud, Nawal 05 1900 (has links) (PDF)
Cette thèse traite des possibilités d'utilisation de deux techniques d'espace de tête - spectrométrie de masse (DHS-MS et SPME-MS) pour la caractérisation rapide des composés volatils et semi-volatils du liège oenologique dans le cadre d'applications "origine contrôlée" et "contrôle qualité" des bouchons basée sur leur critères olfactifs. Les étapes préliminaires nécessaires à la mise au point du DHS-MS et de la SPME-MS ont permis de déterminer les paramètres de l'analyse selon des critères basés sur la simplicité de mise en oeuvre, la rapidité de l'analyse par rapport à des méthodes classiques (GC-MS et l'analyse sensorielle) et la stabilité du système évaluée par le coefficient de variation et par une analyse de variance. Ces deux techniques ont été mises en oeuvres suivant deux axes d'études distincts : Le DHS-MS: le potentiel discriminant de cette technique a été évalué sur des échantillons de rondelles de liège miroirs à travers deux applications (discrimination de l'origines géographique des échantillons et discrimination des échantillons présentant des intensités croissantes d'odeur de moisi). Les méthodes d'analyses multivariées (ACP et PLS) employées aux traitement des résultats se sont avérées efficaces. Cependant, le traitement des données a montré que l'information chimique spécifique aux différences entre les échantillons peut être masquée ou noyée par les spectres de masses des composés non caractéristiques ou présents en grande quantité dans l'espace de tête du DHS-MS. La filtration des données peut alors être une solution permettant de mieux cibler l'information discriminante. Par ailleurs, les empreintes spectrales des échantillons analysés à des périodes différentes peuvent contenir une source de variabilité entraînant une baisse du pouvoir prédictif du modèle. Dans ce cas une remise à jour du modèle, présente alors une solution efficace à ce problème. Le SPME-MS: le potentiel discriminant du cette technique a été évalué sur des échantillons de planches de liège brutes à travers une étude de discrimination de l'origine géographique des échantillons. Le traitement des résultats a montré que ce couplage permet de distinguer facilement les lièges africains des lièges ibériques. Cependant, nous n'avons pas pu accéder à l'information discriminante entre les échantillons ibériques. Avec des résultats de discrimination encourageants et des durées d'analyses relativement courtes de 27 et de 12 minutes par échantillon, le DHS-MS et la SPME-MS ont toutefois montré que leur utilisation présentaient des limites et des difficultés que nous avons tenté de définir et de discuter tout au long de ce travail.

Page generated in 0.0804 seconds