• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1133
  • 26
  • 26
  • 26
  • 26
  • 18
  • 14
  • 11
  • 10
  • 5
  • 4
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 1173
  • 779
  • 119
  • 111
  • 97
  • 86
  • 77
  • 77
  • 71
  • 70
  • 69
  • 67
  • 65
  • 64
  • 63
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
61

Modificação eletroquímica da superfície de filmes finos de ouro SERS e SPR ativos

Jarske, André Oliveira Silva January 2011 (has links)
Thin metal films have attracted much interest because they provide a way to produce surface plasmon resonance (SPR) in the Kretschmann configuration. This technique is a very sensitive for determining small changes at the interface between a metallic layer and a dielectric medium, and the metals generally used are silver and gold once their surface plasmon resonances are located in the visible range. Thin films of gold, due their stability and diversity applications, have been extensively studied by electrochemistry, surface enhanced Raman spectroscopy (SERS) and techniques of Microscopic such as AFM and STM. The Raman technique has been used to the analysis of organics compounds in determined system. However, in very low concentration levels is inefficient due to weak signal or interference from noise. A developed method to markedly increase the signal of a species presented at many levels is the SERS. One of the major considerations for the formation of a SERS-active surface is surface roughness, and this has been realized by various ways. In the present work, we analyzed the efects of various oxidation-reduction cycles (ORCs) on the surface of the thin films of gold using the techniques of cyclic voltammetry, microscopy, UV-Vis spectroscopy and SPR, which will be used to evaluate the efficiency of electrochemically modified substrates as SERS and SPR active. Initially, the film was cycling in a solution of H2SO4 to remove impurities from the surface. After this procedure, the 50 nm and 100 nm thick gold films, deposited on a glass substrate, were subjected to a series of ORCs in a solution of H2SO4 containing 0,005 M KCl electrolyte. As the number of ORCs is increased, the roughness of the film increased. We used techniques of microscopy, Spectroscopy UV-Vis, Resonance Plasmon Surface and Cyclic Voltammetry to characterize the surface of the film as a function of roughness. A “home − made” SPR system based on the configuration of Kretschmann was utilized for analyzed the changes provoked in surface film before and after the electrochemically modified. The medium size of the gold islands deposited was analyzed for Atomic Force Microscopy (AFM) and Scanning Tunneling Microscopy (STM). This same metallic film, after passing for oxidation processes and reduction, was used to obtain a spectrum SER using an organic molecule the 2-thiouracil adsorbed on the surface of the film. The results observed for AFM, STM and cyclic voltammetry shows that surfaces electrochemically modified increase the roughness, and that the changes modified o depth of the signal SPR. These change provoked electrochemistry after various ORC improve significantly the Raman sign of molecules adsorbed on the surfaces of the metallic films. Finally, we conducted an evaluation of the roughness factor obtained through the techniques of AFM, STM and cyclic voltammetry. _______________________________________________________________________________________ RESUMO: Filmes finos metalicos tem despertado muito interesse devido a possibildade de produzir Ressonancia de Plasmons de Superfıcie (SPR) utilizando uma configuracao de Kretschmann. Esta tecnica e muito sensıvel na determinacao de pequenas mudancas na interface entre uma camada metalica e um meio dieletrico, e os metais usados geralmente sao prata e ouro, uma vez que a ressonancia de plasmon da superfıcie desses metais esta localizada na regiao do visıvel. Esses filmes, devido a sua estabilidade e diversidade de aplicacoes, tem sido extensivamente estudados por tecnicas eletroquımicas, espectroscopia Raman intenficada por superfıcie (SERS) e por tecnicas de microscopia tais como o AFM e STM. A Espectroscopia Raman tem sido utilizada para a analise de compostos organicos em determinados sistemas. No entanto, em sistemas que possuem concentracoes muito baixas, o sinal Raman e extremamente fraco e ineficiente, ou sofre interferencias de ruıdos. Um dos metodos desenvolvidos para aumentar significativamente o sinal de uma especie adsorvida sobre uma superfıcie metalica em varios nıveis e o SERS. Uma das consideracoes importantes para a formacao de um substrato SERS ativo e a rugosidade da superfıcie, e a obtencao dessas superfıcies tem sido realizado de diversas maneiras. No presente trabalho, analisamos o efeito de diferentes ciclos de oxidacao-reducao (ORCs) sobre a superfıcie de filmes finos de ouro, utilizando as tecnicas de voltametria cıclica, microscopias, espectroscopia UV-Vis e SPR, que serao utilizadas para avaliar a eficiencia dos substratos modificados eletroquimicamente como SERS e SPR ativos. Inicialmente, o filme e ciclado em uma solucao de H2SO4 para remover as impurezas da superfıcie. Apos este procedimento, os filmes com espessuras de 50 e 100 nm, depositados sobre um substrato de vidro, foram submetidos a uma serie de ORCs em uma solucao de H2SO4.
62

Superfícies com curvatura gaussiana constante e vetor curvatura média normalizado paralelo

Souza, José Roberto Guimarães de 20 June 2014 (has links)
Submitted by Divisão de Documentação/BC Biblioteca Central (ddbc@ufam.edu.br) on 2015-11-03T10:11:33Z No. of bitstreams: 1 Dissertação - José Roberto.pdf: 1479021 bytes, checksum: 108a79be3b0cfe5702a5a3bc10672dbf (MD5) / Approved for entry into archive by Divisão de Documentação/BC Biblioteca Central (ddbc@ufam.edu.br) on 2015-11-03T10:15:29Z (GMT) No. of bitstreams: 1 Dissertação - José Roberto.pdf: 1479021 bytes, checksum: 108a79be3b0cfe5702a5a3bc10672dbf (MD5) / Approved for entry into archive by Divisão de Documentação/BC Biblioteca Central (ddbc@ufam.edu.br) on 2015-11-05T18:29:02Z (GMT) No. of bitstreams: 1 Dissertação - José Roberto.pdf: 1479021 bytes, checksum: 108a79be3b0cfe5702a5a3bc10672dbf (MD5) / Made available in DSpace on 2015-11-05T18:29:03Z (GMT). No. of bitstreams: 1 Dissertação - José Roberto.pdf: 1479021 bytes, checksum: 108a79be3b0cfe5702a5a3bc10672dbf (MD5) Previous issue date: 2014-06-20 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / The objective of this work is to show that "M" is an analytic surface, oriented and closed the Euclidean space "Em" a constant Gaussian curvature and vector average curvature standard parallel, then either "M" is in a hypersphere of "Em" as a minimum area or "M" is a surface product of two circles plans. / O objetivo deste trabalho é mostrarmos que se "M" é uma superfície analítica, orientada e fechada do espaço euclideano "Em" com curvatura Gaussiana constante e vetor curvatura médio normalizado paralelo, então ou "M" está em uma hiperesfera de "Em" como uma superfície mínima ou "M" é uma superfície produto de dois círculos planos.
63

Análise da rugosidade superficial de diferentes marcas comerciais de resina acrílica para coroas provisórias / Surface roughness analysis of acrylic resin for provisional crowns under different commercial brands

Cintia Lumi Nishida 30 June 2010 (has links)
As coroas provisórias apresentam algumas características que podem comprometer a estética e facilitar aderência de microorganismos e formação de placa. Estudos prévios demonstraram que a forma de processamento influi na rugosidade e porosidade de uma marca comercial de resina acrílica comumente utilizada para a confecção de provisórias. Como diferentes marcas comerciais apresentam diferenças de qualidade, o presente estudo teve como objetivo principal avaliar a rugosidade superficial de quatro marcas comerciais de resina acrílica utilizadas na confecção de coroas provisórias (Dencor, Vipi, Duralay e Alike) de acordo com quatro técnicas de manipulação, diretas e indiretas. Os processamentos avaliados foram: GRUPO I autopolimerização sob pressão em matriz de silicona; GRUPO II - autopolimerização térmica em mufla; GRUPO III autopolimerização utilizando a técnica do pincel; GRUPO IV autopolimerização pela mistura em pote dappen. Para cada tipo de processamento foram confeccionados 12 corpos-deprova de cada material, totalizando 48 corpos-de-prova para cada grupo e 192 espécimes ao total. Logo após a confecção dos espécimes foi realizado o teste de rugosidade de superfície (Ra) através de um rugosímetro/perfilômetro. Posteriormente, a superfície dos mesmos foi uniformizada e polida com a utilização de politriz, realizando-se novamente os mesmos testes de rugosidade. Antes do acabamento e polimento de superfície, os resultados encontrados apontaram a maior rugosidade para resina Vipi (4,074 ± 0,541) e técnica da mistura em dappen gupo IV (3,538 ± 0,509), enquanto que a menor rugosidade foi encontrada para resina Alike (2,671 ± 0,512) e técnica da prensagem em mufla grupo II (2,733 ± 0,470). Após acabamento e polimento, a maior rugosidade foi encontrada para resina Vipi (0,207 ± 0,032) e técnica da pressão grupo I (0,172 ± 0,037), enquanto que a menor rugosidade para resina Alike (0,113 ± 0,036) e técnica da prensagem em mufla grupo II (0,138 ± 0,027). Com os resultados obtidos, foi possível concluir que a melhor combinação para confecção de coroas provisórias em resina acrílica foi a técnica da prensagem em mufla associada à resina Alike. / Provisional crowns have some features that may compromise aesthetics and favors adherence of microorganisms and dental plaque formation. Previous studies have shown that processing may influence roughness and porosity of acrylic resins commonly used make provisional crowns. Because the several commercial resins available present differences in their quality the aim of this study was to evaluate the surface roughness of four commercial brands of acrylic resins (Dencor, Vipi, Duralay and Alike) according to four manipulation techniques (two direct and two indirect): GROUP I - autopolimerization under pressure in a silicone matrix; GROUP II autppolimerization in flask; GROUP III - autopolimerization using the bead brush technique; GROUP IV - autopolimerization after mixing in dappen dish. For each type of processing 12 specimens were made of each material, being 48 specimens for each group and 192 specimens in total. After specimens preparation, surface roughness tests (Ra) was performed using a rugosimeter / profilometer. Posteriorly, all surfaces were polished for standardization and same roughness tests were performed again. Before finishing and polishing, the results pointed out that Vipi resin presented the highest roughness (4.074 ± 0.541). Mixing the resin in dappen dish group IV (3.538 ± 0.509) also presented the highest roughness values regarding the technique. The lowest roughness values were found with Alike resin (2.671 ± 0.512) and flask technique group II (2.733 ± 0.470). After finishing and polishing techniques, the highest roughness was found with Vipi resin (0.207 ± 0.032) and the autopolimetization under pressure in silicone matrix technique - group I (0.172 ± 0.037). The lowest roughness values were found with Alike resin (0.113 ± 0.036) and flask technique group II (0.138 ± 0.027). With these results, it was possible to conclude that the best combination for making provisional crowns was the flask technique associated with Alike resin.
64

Geoquímica multielementar de sedimentos de corrente no Estado de São Paulo: abordagem através da análise estatística multivariada / not available

Mapa, Felipe Brito 10 March 2016 (has links)
Este trabalho apresenta resultados geoquímicos multielementares de sedimentos de corrente no estado de São Paulo, obtidos através do projeto institucional do Serviço Geológico do Brasil denominado \"Levantamento Geoquímico de Baixa Densidade no Brasil\". Dados analíticos de 1422 amostras de sedimento de corrente obtidos por ICP-MS (Inductively Coupled Plasma Mass Spectrometry), para 32 elementos químicos (Al, Ba, Be, Ca, Ce, Co, Cr, Cs, Cu, Fe, Ga, Hf, K, La, Mg, Mn, Mo, Nb, Ni, P, Pb, Rb, Sc, Sn, Sr, Th, Ti, U, V, Y, Zn e Zr), foram processadas e abordadas através da análise estatística uni e multivariada. Os resultados do tratamento dos dados através de técnicas estatísticas univariadas forneceram os valores de background geoquímico (teor de fundo) dos 32 elementos para todo estado de São Paulo. A análise georreferenciada das distribuições geoquímicas unielementares evidenciaram a compartimentação geológica da área. As duas principais províncias geológicas do estado de São Paulo, Bacia do Paraná e Complexo Cristalino, se destacam claramente na maioria das distribuições geoquímicas. Unidades geológicas de maior expressão, como a Formação Serra Geral e o Grupo Bauru também foram claramente destacadas. Outras feições geoquímicas indicaram possíveis áreas contaminadas e unidades geológicas não cartografadas. Os resultados da aplicação de métodos estatísticos multivariados aos dados geoquímicos com 24 variáveis (Al, Ba, Ce, Co, Cr, Cs, Cu, Fe, Ga, La, Mn, Nb, Ni, Pb, Rb, Sc, Sr, Th, Ti, U, V, Y, Zn e Zr) permitiram definir as principais assinaturas e associações geoquímicas existentes em todo estado de São Paulo e correlacioná-las aos principais domínios litológicos. A análise de agrupamentos em modo Q forneceu oito grupos de amostras geoquimicamente correlacionáveis, que georreferenciadas reproduziram os principais compartimentos geológicos do estado: Complexo Cristalino, Grupos Itararé e Passa Dois, Formação Serra Geral e Grupos Bauru e Caiuá. A análise discriminante multigrupos comprovou, estatisticamente, a classificação dos grupos formados pela análise de agrupamentos e forneceu as principais variáveis discriminantes: Fe, Co, Sc, V e Cu. A análise de componentes principais, abordada em conjunto com a análise fatorial pelo método de rotação varimax, forneceram os principais fatores multivariados e suas respectivas associações elementares. O georreferenciamento dos valores de escores fatoriais multivariados delimitaram as áreas onde as associações elementares ocorrem e forneceram mapas multivariados para todo o estado. Por fim, conclui-se que os métodos estatísticos aplicados são indispensáveis no tratamento, apresentação e interpretação de dados geoquímicos. Ademais, com base em uma visão integrada dos resultados obtidos, este trabalho recomenda: (1) a execução dos levantamentos geoquímicos de baixa densidade em todo país em caráter de prioridade, pois são altamente eficazes na definição de backgrounds regionais e delimitação de províncias geoquímicas com interesse metalogenético e ambiental; (2) a execução do mapeamento geológico contínuo em escala adequada (maiores que 1:100.000) em áreas que apontam para possíveis existências de unidades não cartografadas nos mapas geológicos atuais. / This research introduces multi-element geochemical results from stream sediments samples in São Paulo State, obtained from the institutional project entitled \"Low Density Geochemical Mapping in Brazil.\" A total of 1422 stream sediment samples were collected and 32 chemical elements (Al, Ba, Be, Ca, Ce, Co, Cr, Cs, Cu, Fe, Ga, Hf, K, La, Mg, Mn, Mo, Nb, Ni, P, Pb, Rb, Sc, Sn, Sr, Th, Ti, U, V, Y, Zn and Zr) determined by ICP-MS (Inductively Coupled Plasma Mass Spectrometry). Uni-variate and multivariate statistic analysis were used to explore the data. The uni-variate statistics results of processed data provided geochemical background values of the 32 elements for São Paulo State. The geo-referenced analysis of uni-element geochemical distributions showed the geological domains of the area. The two main geological provinces of São Paulo, Paraná Basin and Crystalline Basement, standed out clearly at most of the geochemical distributions. Geological units of larger extension, such as Serra Geral Formation and the Bauru Group were also clearly highlighted. Other geochemical features indicated possible contaminated areas and uncharted geological units. Geochemical multivariate analysis for 24 variables (Al, Ba, Ce, Co, Cr, Cs, Cu, Fe, Ga, La, Mn, Nb, Ni, Pb, Rb, Sc, Sr, Th , Ti, U, V, Y, Zn and Zr) allowed to define the main signatures and existing geochemical associations at São Paulo State and its correlation to the main lithological domains. Q mode cluster analysis provided eight groups of geochemically correlated samples, which reproduced the main geo-referenced geological domains from the State: Crystalline Basement, Passa Dois and Itararé Groups, Serra Geral Formation and Bauru and Caiuá Group. The multi-groups discriminant analysis, statistically attested the classification of groups formed by cluster analysis, and determined Fe, Co, Sc, V e Cu as the main discriminant variables. The principal component analysis, discussed along with the factor analysis by varimax rotation method, provided the main multivariate factors and their elemental associations. The geo-referencing of the factorial values of multivariate scores delimited areas where the elementary associations occur and provided multivariate maps for the state. At last, it was concluded that applied statistical methods are crucial at the treatment, presentation and interpretation of geochemical data. Furthermore, based on an integrated outlook of the results obtained, this study recommends: (1) the application of low density geochemical surveys in the country as a matter of priority, as these surveys are highly effective in defining regional backgrounds and geochemical provinces delineation with metallogenic and environmental interest, and (2) the continuous geological mapping implementation at an adequate scale (greater than 1: 100,000), for areas that indicate possible units not yet mapped in the current geological maps.
65

Desenvolvimento de uma superfície bifuncional Pt/Au modificada com glicose oxidase para determinação de glicose em amostras alimentícias / Development of a bifunctional surface Pt/Au modified with glucose oxidase for glucose determination in food samples

Dadamos, Tony Rogério de Lima 19 July 2013 (has links)
A glicose é um açúcar redutor importante na dieta humana, sendo abundante em diversos alimentos, como sucos de frutas, mel, iogurtes e refrigerantes e pode ser facilmente ingerido e metabolizado. Ela fornece a energia para o corpo humano, entretanto, diversos desequilíbrios metabólicos estão associados com variações no teor de glicose no sangue, saliva ou urina. Sendo assim é preciso desenvolver métodos de baixo custo, simples e rápidos que permitam o monitoramento deste metabólito. Portanto, no presente trabalho foi desenvolvido e caracterizado um eletrodo composto por uma superfície bifuncional de Pt/Au, onde a superfície de Au foi modificada com uma monocamada auto-organizada de cistamina na qual foi ancorada a enzima glicose oxidase e a superfície da Pt com ferroceno, para determinação de glicose em amostras alimentícias. O eletrodo foi construído utilizando-se um eletrodo de platina, sobre o qual foram eletrodepositado nanoestruturas de ouro, através de voltametria linear em uma solução contendo o ânion tetracloroáurico. As nanoestruturas de ouro foram modificadas com o alcanotiol cistamina, formando uma camada auto-organizada, para servir de plataforma para ancoragem da glicose oxidase. O peróxido de hidrogênio, que é um dos produtos da reação enzimática foi determinado na platina modificada com ferroceno. Sendo assim, as nanoestruturas de ouro serviriam de sítios específicos para as enzimas, e a platina modificada com ferroceno servirá para quantificar o produto da reação enzimática. Para a detecção da glicose foram construídos três eletrodos, o eletrodo embutido (EE) para detecção de glicose em refrigerantes, o eletrodo por evaporação de platina (EEP) para detecção de glicose em amostras de iogurte e o ultramicroeletrodo (UME) para futuras aplicações de detecção de glicose por métodos não invasivos. Encontrou-se um limite de detecção de 2,4 µmol L-1 para o eletrodo EE, de 2,2 µmol L-1 para o eletrodo EEP e 0,03 µmol L-1 para o UME. Foram realizados diversos tratamentos estatísticos como erro relativo, desvio padrão e incertezas para verificar a resposta do eletrodo. Por fim, os eletrodos desenvolvidos foram aplicados na detecção de glicose em amostras de refrigerantes, chás e iogurtes, e obteve-se uma resposta satisfatória para a detecção do analito nestas amostras. / Glucose is a reducing sugar very important in the human diet and is abundant in many foods, such as fruit juices, honey, yogurt and soft drinks and can be easily ingested and metabolized. It provides the energy for the human body perform its healthy functioning. However, many metabolic imbalances associated with variations in the level of glucose in the blood, urine or saliva. Therefore it is necessary to develop methods cheap, simple and quick to allow the monitoring of this metabolite. Therefore, in the present work was developed and characterized an electrode composed of a bifunctional surface Pt/Au, where Au surface was modified with a selforganized monolayer of cystamine which was anchored in the enzyme glucose oxidase and the surface of Pt with ferrocene for the determination of glucose in food samples. The electrode was constructed using a platinum electrode, which was electrodeposited gold nanostructures, using the technique of linear voltammetry in a solution containing the anion tetrachloroauric. The gold nanostructures were modified with cystamine alkanethiol forming a self-organized layer to serve as a platform for anchoring the glucose oxidase. Hydrogen peroxide, which is a product of the enzyme reaction, was determined in the platinum modified with ferrocene. Therefore, the gold nanostructures serve as sites for specific enzymes, and platinum modified with ferrocene serve to quantify the product of the enzymatic reaction. For detection of glucose were built three electrodes, the electrode embedded (EE) for detecting glucose in soft drinks, the electrode by evaporating platinum (EEP) for detection of glucose in samples of yogurt and ultramicroelectrode (UME) for future sensing applications glucose through non-evasive. We found a detection limit of 2.4 µmol L-1 to the electrode EE, 2.2 µmol L-1 to the electrode EEP and 0.03 µmol L-1 for UME. Various statistical treatments were performed as relative error, standard deviation and uncertainties to check the response of the electrode. Finally, the electrodes developed were applied to the detection of glucose in samples of soft drinks, teas and yogurts, which gave a satisfactory response to the detection of the analyte in food samples.
66

Funcionalização da superfície de metais através da produção de nanoestruturas periódicas produzidas por laser pulsado de femtosegundo / Functionalization of the metals surface through the production of periodic nano-structures produced by femtosecond laser pulses

Silva, Leandro Gusmão da 30 March 2017 (has links)
Neste trabalho, foram realizados diversos experimentos para a criação controlada de nanoestruturas superficiais produzidas por Laser pulsado de femtossegundo em Titânio e em aço inoxidável, ambos utilizados para fins cirúrgicos e industriais. Os parâmetros alterados nos experimentos foram a Fluência do laser, a taxa de sobreposição de pulsos, polarização do feixe e atmosfera de processamento. A vantagem na utilização do laser de femtossegundo para essas aplicações é a possibilidade de ser criar tais estruturas sem que haja aquecimento crítico do material, evitando assim, a criação de óxidos ou nitretos superficiais, já que esses a formação desses materiais superficiais pode afetar o desempenho industrial e cirúrgico dos materiais. Após o entendimento dos parâmetros de irradiação na formação das nanoestruturas, foram propostas três aplicações possíveis para a superfície resultante do processamento com laser: Superfícies coloridas, que podem ser utilizadas em personalização de peças; Superfícies escuras, que podem ser utilizadas na marcação e tipagem de peças; e um Micro Aquecedor, que pode ser utilizado no controle de temperaturas dentro de circuitos microfluídicos. / In this work, several experiments were carried out for the controlled creation of surface nanostructures produced by femtosecond laser pulses in Titanium and stainless steel, both used for surgical and industrial purposes. The altered parameters in the experiments were the laser Fluence, the overlap pulses rate, the beam polarization and processing atmosphere. The advantage of using femtosecond laser for such applications is the possibility of creating the nanostructures without critical heating of the material, thus avoiding the creation of surface oxides or nitrides, since the formation of such surface materials may affect the industrial and surgical materials performance. After the understanding of the irradiation parameters in the formation of the nanostructures, three possible applications were proposed for the surface resulting from the laser processing: Colored surfaces, which can be used in personalization of parts; Dark surfaces, which can be used in parts marking; and a Micro Heater, which can be used to control temperatures inside microfluidic circuits.
67

Estudo clínico retrospectivo de avaliação da taxa de sobrevivência de implantes osseointegrados com superfície Acqua / Retrospective clinical evaluating study of dental implants survival rate with Acqua surface

Lopes Júnior, Itamar 26 August 2016 (has links)
A reposição de dentes perdidos por meio de próteses implanto-suportadas tornou-se uma opção de tratamento previsível e aceitável tanto para pacientes parcialmente como totalmente desdentados. Após sua instalação, os implantes de titânio interagem com fluidos biológicos e tecidos, sendo que a direta aposição óssea sobre a superfície do titânio é fundamental para o carregamento desses implantes. As características superficiais dos implantes podem influenciar na interação implanteosso, na taxa e qualidade da osseointegração. O objetivo desse estudo clínico retrospectivo foi avaliar a taxa de sobrevivência de implantes osseointegrados com superfície Acqua e verificar se existe interferência de determinadas variáveis na perda de implantes: região de instalação, tipo de reabilitação protética, tipo de carregamento, tempo de carregamento, experiência do cirurgião, enxertos ósseos, tipo de sítio para instalação, uso de tabaco e diabetes. Foram avaliados 131 pacientes, totalizando 331 implantes instalados com conexão interna tipo cone Morse e superfície Acqua. Os dados foram coletados de prontuários clínicos e tabulados e nenhum paciente foi excluído devido a qualquer doença sistêmica, gênero, raça, hábitos parafuncionais e tabagismo. A análise estatística incluiu estatísticas descritivas para todos os parâmetros clínicos avaliados e foi aplicado o método exato de Fisher. Foram avaliados implantes instalados anteriormente a março de 2014 e o tempo de acompanhamento do carregamento dos implantes foi de 0 a 55 meses. Entre as variáveis avaliadas apenas o tipo de reabilitação protética influenciou de forma significativa na falha de implantes. Sete implantes (2,11%) foram considerados perdidos, totalizando uma taxa de sobrevivência de 97,89%. Os implantes com superfície Acqua apresentaram alto índice de sobrevivência nas mais diversas situações e com a associação de diversos fatores de risco, provando ser uma superfície confiável e apropriada para a aplicação na prática clínica diária. / The replacement of lost teeth by dental implant has become a predictable and acceptable treatment option for patients either partially or fully edentulous. After place, titanium implants surface interact with biological fluids and tissues, and direct bone apposition on the titanium surface is critical for loading these implants. The surface characteristics of implants can influence the implant-bone interaction in the rate and quality of osseointegration. The aim of this retrospective clinical study was to evaluate the dental implants survival rate with Acqua surface and check for interference of certain variables in the loss of implants: placed region, type of prosthetic rehabilitation, loading type, load time, surgeon experience, bone grafts, installation site, tobacco use and diabetes. One hundred thirty one patients, totaling 331 implants inserted with internal Morse taper connection and Acqua surface. Data were collected from medical records and tabulated and no patient was excluded due to any systemic disease, gender, race, parafunctional habits and smoking. Statistical analysis included descriptive statistics for all clinical parameters evaluated and was applied Fishers exact test. Were evaluated implants placed prior to March 2014 and the follow-up time of loading of the implants was 0-55 months. Among the variables evaluated only the type of prosthetic rehabilitation influenced significantly in implant failure. Seven implants (2.11%) were considered lost, amounting to a survival rate of 97.89%. Implants with Acqua surface showed high survival rate in different situations and with the association of various risk factors, proving to be a reliable and suitable surface for application in clinical practice.
68

Análise histomorfométrica de implantes hidrofóbicos e hidrofílicos: estudo experimental em coelhos / Comparative histomorphometric analysis of hydrophobic and hydrophilic implants: an experimental study in rabbits

Cunha, Verena Souza da 03 June 2015 (has links)
O íntimo contato entre osso e implante é considerado um pré-requisito fundamental para o sucesso dos implantes dentários, condição esta conhecida como osseointegração. Devido a isto, um grande número de pesquisas com tratamentos de superfícies de implantes vem sendo desenvolvido por várias empresas nos últimos anos, visando acelerar esse fenômeno. O objetivo deste trabalho é avaliar histomorfometricamente o percentual de contato osso-implante (BIC) e área de osso novo (BA) entre implantes de tratamento de superfície Neoporos (GC - hidrofóbico) e implantes com energia de superfície molhada Acqua (GE - hidrofílicos). Foram utilizados 15 coelhos da raça new zealand, que receberam 30 implantes divididos em cada lado de suas tíbias direita e esquerda, ambos de titânio comercialmente puro grau IV com 3.5x8mm de dimensão, sendo ao final de 15 dias, a região dos implantes coletada e processada histologicamente para obtenção de cortes teciduais não desmineralizados, embora dois implantes do grupo Esm tenham sido excluídos da pesquisa devido à instalação ter ocorrido dentro do canal medular e terem obtido tecido necrosado, não cumprindo as características de osseointegração. Para análise dos dados estatísticos, utilizou-se o teste t de Students para amostras independents e teste Mann-Whitney Rank Sum com nível de significância de p<0.05. Os resultados mostraram que não houve diferença estatisticamente significante entre os grupos para a análise de BIC. O grupo GC apresentou a média de 42.9% de BIC, ligeiramente menor que o grupo GE, que apresentou 49.3% de média. Já para o teste BA houve diferenças de 15%, em que o grupo GC apresentou 58.6% e o grupo GE, 74.4%. A conclusão é que há, ainda, necessidade de maiores estudos a cerca do referido tema. / The near contact between bone and implant is considered an essential pre-requisite for the success of dental implants, a condition known as osseointegration. Due to it, a great amount of researches on implants surface treatments has been developed by several companies in recent years to accelerate the phenomenon of osseointegration. The aim of the present study is to evaluate histomorphometrically the percentage of bone-implants contact (BIC) and the area of new bone (BA) between implants with surfaces treatment Neoporos (GC - hydrophobic) and implants with wets surface energy Acqua (GE - hydrophilic). It was used fifteen (n=15) New Zealand rabbits, which received thirty implants installed dividing them between its right and left tibias. Implants were commercially pure titanium grade IV with 3.5x8mm dimension. After fifteen days, the implants area were collected and processed histologically in order to obtain not demineralized tissue sections. For statistical data analysis, it was used the t test for independents samples and Mann-Whitney Rank Sum test. The significance level was p<0.05. Results showed no statistical significant difference between groups for BIC analysis. The control group showed a mean of 42.9% of BIC, slightly lower than the GE group, which showed a mean of 49.3%. For BA test, there was a significant difference of more than 15% in the control group (58.6% for the GC group and 74.4% for GE group). It was concluded that futher studies is needed on this topic of osseointegration and hydrophobic /hydrophilic implants.
69

Avaliação da superfície radicular após instrumentação manual, ultra-sônica e ultra-sônica seguida de instrumentação manual utilizando dentes mineralizados e desmineralizados / Evalution of root surface after manual and ultra-sonic instrumentation, following by a manual instumentation, utilizing mineralized and desmineralized teeth

Justo, Flávio Roberto Machado 20 March 2003 (has links)
O presente trabalho avaliou o efeito do tratamento da superfície radicular por meio da instrumentação com curetas, US e US seguido de curetas, utilizando dentes mineralizados e desmineralizados conjugando a utilização de cítrico e tetraciclina. As superfícies dentais foram analisadas em MEV por um único examinador, sendo utilizados 66 dentes unirradiculares com presença de cálculo indicando doença periodontal. Os dentes foram divididos em 6 grupos experimentais com 10 dentes cada e um grupo controle com 6 dentes sem tratamento. O protocolo de tratamento dos grupos seguiu a seguinte orientação: grupo 1- dentes mineralizados instrumentados com curetas; grupo 2- dentes mineralizados instrumentados com US; grupo 3- dentes mineralizados instrumentados com US, seguindo-se instrumentação com curetas; grupo 4- dentes instrumentados com curetas, desmineralizados e novamente instrumentados com curetas; grupo 5 - dentes instrumentados com US, desmineralizados e novamente instrumentados com US; e, grupo 6- dentes instrumentados com US, desmineralizados e novamente instrumentados com curetas. Foram analisadas a quantidade de cálculo residual (ICR), a rugosidade da superfície radicular (IRS) e perda da substância dentária (IPSD). Os resultados demonstraram diferenças estatísticas significativas quanto ao ICR do grupo 2 em relação aos grupos 3, 4 e 6 e do grupo 5 com os grupos 4 e 6; quanto ao IRS houveram diferenças estatísticas significativas entre o grupo 2 e os grupos 1, 4 e 6 e entre o grupo 5 e os grupos 1 e 6; quanto ao IPSD, observou-se que não houve diferenças estatísticas significativas entre os grupos. O uso de curetas isoladamente ou após US parece melhor se ajustar aos critérios de preparo adequado da raiz, em função dos parâmetros avaliados. / The present work aimed at evaluating the effect of root treatment by instrumentation of not only mineralized teeth with curettes, ultra-sonics (US) and US followed by curettes, but also of teeth intermediately demineralized in combined instrumentations, by using citric acid and tetracycline. The dental surfaces were analysed on SEM by a unique examiner, being utilized 66 uniradicular teeth presenting calculus and thus indicating periodontal disease. The teeth were divided into 6 experimental groups with 10 teeth each and a control group consisting of 6 teeth with no treatment. The treatment protocol for the groups was as follows: group 1- mineralized teeth instrumented with curettes; group 2- mineralized teeth instrumented with US; group 3- mineralized teeth instrumented with US, followed by curette; group 4 - teeth instrumented with curettes, demineralized and again instrumented with curettes; group 5 - teeth instrumented with US, demineralized and again instrumented with US; and, group 6- teeth instrumented with US, demineralized and instrumented with curettes. The amount of residual calculus (RCI), roughness of the radicular surface (SRI) and loss of dental substance (LTSI) were assessed. The results demonstrated statistically significant differences regarding the RCI of group 2 in relation to groups 3, 4 and 6, and that of group 5 with groups 4 and 6; as for the SRI, there were statistically significant differences between group 2 and groups 1, 4 and 6, and between group 5 and groups 1 and 6; no statistically significant differences were observed for the LTSI among groups. The use of curettes, alone or following US, seems more suitable for the criteria of adequate root preparation, as a function of the parameters evaluated.
70

Potencial de superfície e condutância em filmes de Langmuir / Surface potential and lateral conductance in Langmuir films

Cavalli, Ailton 18 February 1993 (has links)
Filmes de Langmuir de fosfolipídios e ácidos graxos foram caracterizados através de medidas de pressão e potencial de superfície e condutância lateral. O objetivo principal foi o de se fazer um estudo crítico de artigos apresentados na literatura, os quais trazem interpretações errôneas para resultados do potencial de superfície, sugerem a heterogeneidade dos filmes, ou a inexistência do aumento da condutância devido a compressão de um filme de Langmuir. Comprovamos, inicialmente, a homogeneidade macroscópica dos filmes de ácidos graxos e fosfolipídios, medindo-se o potencial com a prova de Kelvin em três posições diferentes. Nenhuma alteração significativa foi registrada. O potencial e a pressão de superfície são nulos para grandes áreas por molécula, sendo que o potencial só se torna não nulo após um aumento abrupto, que ocorre a uma certa área critica. Estes resultados, juntamente com a ausência de histerese nas medidas de pressão e potencial de superfície nos ciclos de compressão-expansão, denotam a inexistência de agregados de dimensões macroscópicas. Eles contradizem, entretanto, a asserção de alguns pesquisadores na ultima conferencia de filmes Langmuir-Blodgett, de que a presença de domínios microscópicos nos filmes de Langmuir deveria afetar os resultados do potencial de superfície. Podemos concluir, portanto, que quaisquer irreprodutibilidades do potencial de superfície para grandes áreas por molécula devem ser atribuídas a impurezas do sistema de medidas, principalmente da subfase. As medidas de condutância foram realizadas diretamente, medindo-se a corrente entre dois eletrodos de platina parcialmente imersos na subfase. Para grandes áreas por molécula, a condutância medida é devido a condutividade de volume da água ultrapura, mas quando o filme e comprimido para áreas menores do que uma certa área critica (a mesma na qual e observado o aumento abrupto do potencial), a condutância sobe ate a pressão de superfície começar a subir, atingindo valores da ordem de 10-8s acima da condutância da subfase. Foram realizadas medidas para um fosfolipídio e um fosfato. Com isso, corroboramos os resultados de condutância, da mesma ordem de grandeza, obtidos em Bangor, no Reino Unido, ao mesmo tempo que são refutadas as observações feitas por grupos de pesquisa dos Estados Unidos e da Rússia. As possíveis causas para a não observação da condutância por esses últimos grupos podem ser o efeito do menisco - queda da área imersa dos eletrodos quando do aumento da pressão de superfície - que mascara o aumento da condutância, ou artefatos experimentais, tais como impurezas na subfase / Langmuir films from phospholipids and fatty acids were characterized using surface pressure, surface potential and lateral conductance measurements. The main aim of this project was to undertake a critical study of articles published in the literature which present erroneous interpretations for surface potential results, suggest non-homogeneity of Langmuir films, or rule out the possible increase in conductance upon the compression of a monolayer. First, we demonstrate that phospholipids and fatty acid mono layers are homogeneous at the macroscopic level, by measuring their surface potential with the Kelvin probe on three different positions. No significant difference was observed. The surface potential and surface pressure is zero for large areas per molecule, and the surface potential only becomes non-zero when an abrupt increase takes place at a given critical area. Together with the absence of hysteresis in the surface pressure and surface potential measurements in the compression-expansion cycles, these results indicate the absence of aggregates (or islands) of macroscopic dimensions. They contradict, however, the opinion of some authors at the last Conference on Langmuir-Blodgett Films, who took the view that the presence of micro domains on Langmuir monolayers should affect the surface potential measurements. We can conclude, therefore, that any non-reproducibility of surface potentials at large areas per molecule must be attributed to impurities in the system, especially in the sub-phase. The lateral conductance measurements were performed by measuring the current between two platinum electrodes, which were partially immersed into the sub-phase. For large areas per molecule, the conductance is due to the bulk conductivity of ultra pure water, but when the monolayer was compressed below a given critical area (the same in which a sharp increase in surface potential was observed), the conductance increases until the surface pressure starts to rise, reaching values of the order of 10-8s above the water conductance. Measurements were taken for one phospholipids and one phosphate. This corroborates the results published by the Bangor Group (UK), at the same time that observations made by an American Group and a Russian Group is contradicted. The possible causes for these groups being unable to observe the increase in conductance can be the meniscus effect caused by the decrease of the electrodes immersed area when the pressure rises - which overrun the conductance increase, and/or experimental artifacts, possibly caused by impurities in the sub-phase

Page generated in 0.0447 seconds