• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • Tagged with
  • 4
  • 4
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Energibalansberäkning för flerbostadshus : projekterad energianvändning jämfört med beräknad energianvändning med uppmätta värden för Gävle Strand Etapp 1

Andersson, Robin January 2011 (has links)
Den beräknad mängd energi en byggnad gör av med på ett år visar huruvida den bidrar till ett hållbart samhälle eller inte. AB Gavlegårdarna arbetar inte enbart med att projektera fram förslag till lösningar för framtidens bostäder utan riktar även in sig på sitt nuvarande bestånd när det kommer till energianvändning i flerbostadshus. Gävle Strand Etapp 1 stod klart 2008 med ett bestånd av tolv byggnader som är gestaltade på fyra olika sätt. Alla med olika förutsättningar där främst brukarnas beteende såsom förbrukad mängd tappvarmvatten och hushållsel varierar kraftigt. Under projekteringsfasen anlitades en konsult för att beräkna den köpta energin som dessa bostäder skulle använda och kom fram till en energianvändning på 92 kWh/m2,år. Gavlegårdarnas egna beräkningar som utgick ifrån de verkliga värden som uppmättes för varje lägenhet visade i september 2009 ett medelvärde för hela beståndet som låg på 114 kWh/m2,år. AB Gavlegårdarna vill gå till botten med de problem och den extra kostnad som Gävle Strand Etapp 1 har gett upphov till genom ökad energianvändning, vilket medför att de vill utföra exakta beräkningar på varje byggnads energianvändning. Problemställningen blev därför följande: Hur mycket påverkar FTX-systemets verkningsgrad den totala energiförbrukningen i ett flerbostadshus om systemet inte fungerar som det är tänkt? Kan ett hus bland olika geometriskt utformade hus i ett bestånd anses vara representativ för beståndet, ur energianvändningssynpunkt? Examensarbetet går ut på att genom ett antal U-värdes– och areaberäkningar, ventilations- och luftotäthetsbedömningar, tappvarmvattenanvändning och energibrukarbeteende hos de boende, komma fram till hur mycket en utvald byggnad använder med avseende på specifik energianvändning, med enheten kWh/m2,år. Till författarens hjälp har ett energisimuleringsprogram använts som heter BV2 2010. Resultatet visar att majoriteten av byggnaderna belägna på Gävle Strand Etapp 1 har en högre energianvändning än vad konsultens grundfall visar. Detta på grund av flera faktorer men de främsta orsakerna till den höga energianvändningen i bostäderna är den dåliga temperaturverkningsgraden i FTX-systemets värmeväxlare och brukarbeteendet med en i vissa fall relativt hög användning av tappvarmvatten. / The estimated amount of energy that a building consumes during one year indicates whether it contributes to a sustainable society or not. The communal company, AB Gavlegårdarna , that rents out apartments, works not only with designing proposals for solutions for the future housing , they also work with improving their stock when it comes to energy consumption. The multi-family buildings of Gävle Strand Phase 1 were completed in 2008 with a population of twelve buildings that are shaped in four ways.   During the planning phase a consultant was hired to calculate the how much energy these buildings would have to purchase and came up with an energy use of 92 kWh/m2,year. Gavlegårdarna’s own calculations are based on the actual values obtained for each apartment and in September 2009 and they showed a mean value for the whole stock, which was 114 kWh/m2,year.   AB Gavlegårdarna want to find a solution to the problem and reduce the extra cost that Gävle Strand Phase 1 has given rise through increased use of energy. They want to perform precise calculations on each building's energy use. The problem can be formulated as follows: How much influence does the malfunction of a heat exchanger in a balanced ventilation system have on the total energy consumption in apartment buildings? Can a house among the various geometrically designed houses of a stock be considered to be representative when calculating the energy use of the stock as a whole? The report deals with a number of U-value and area calculations, ventilation and air leakage assessments, domestic hot water use and energy user behavior of the residents, to work out how much a simulated building uses in terms of specific energy, with unit kWh/m2,year. An building simulation program called BV2 2010was utilized. The results show that the majority of the buildings located in Gävle Strand Phase 1 have higher energy consumption than the consultant's basic case. This is due to several factors but the main causes of the high residential energy use is the low temperature efficiency in the FTX-system heat exchanger, the residents’ behavior and in some cases relatively high usage of hot water.
2

Sänkta ventilationsflöden på Sundsvalls sjukhus : Utvärdering av ett energibesparingsinitiativ genom rökförsök och temperaturmätningar

Wickström, Johan January 2017 (has links)
I syfte att sänka energianvändningen på Sundsvalls sjukhus riktas nu fokus mot ventilationssystemet och möjligheterna att där sänka luftflöden. Denna uppsats undersöker detta energibesparingsinitiativ genom att studera vad som händer med luftrörelser och temperaturer i ett rum på sjukhuset vid varierande ventilationsflöden. Metoden är rökförsök med observation och analys av mätdata som jämförs med krav på inomhusklimat och beräkningar av temperatureffektiviteten, ett kvantitativt mått på hur väl tillförd värme kommer rummets vistelsezon tillgodo. Resultaten indikerar bland annat att det kan vara till nackdel för luftkvalitén med alltför drastiska ventilationsflödessänkningar i det observerade rummet, detta fastän mängden tillförd luft är mer än tillräcklig enligt gällande krav. Bäst temperatureffektivitet uppnås då frånluft går via både frånluftsdon och frånluftsfönster vilket pekar mot att bäst förutsättningar för att sänka ventilationsflöden eller tilluftstemperatur finns med denna frånluftsinställning. / With the purpose of lowering energy consumption at Sundsvall Hospital, focus is now being directed towards the ventilation system and the possibility to reduce air flow. The thesis examines this energy-saving initiative by studying what happens to air movements and temperatures in one room at the hospital when ventilation air flow is varied. Air movements were made visible with smoke and observed and temperatures were logged. Observations and data were then analyzed with regard to indoor climate requirements and temperature efficiency, a quantitative measure of how well supplied heat will benefit a room’s occupied zone. The results indicate, among other things, that a too great reduction in air flow rates can have a negative impact on the air quality in the observed room, even though the amount of air supplied is more than sufficient according to current requirements. Best temperature efficiency is achieved when exhaust air passes through both the exhaust air device and the ventilated windows, indicating that this is the most favorable exhaust air setting for lowering ventilation air flow rates or room supply air temperature.
3

Fuktåterföring i roterande värmeväxlare / Moisture feedback in rotating heat exchanger

Malm, Diana January 2012 (has links)
För att ha en chans att ändra trenden med ökande utsläpp av växthusgaser är internationella samarbeten nödvändiga. Därför har EU genom miljökvalitetsmålet Begränsad Miljöpåverkan satt krav på högsta tillåtna utsläpp av växthusgaser. Att sänka energianvändningen för upp- värmning är ett steg i att även sänka utsläpp av koldioxid, som är en av växthusgaserna. Sänkning av energianvändning kan göras på flera sätt, bl.a. genom att öka tjockleken på isoleringen eller återvinna värmen i frånluften. Men dessa åtgärder ska inte helt okritiskt göras.  Att använda roterande värmeväxlare är ett sätt att återvinna värmen i frånluften. Luften passerar då en rotor med öppna kanaler som roterar kring sin egen axel över till tilluftssidan. Detta möjliggör fuktöverföring oberoende om rotorn är hygroskopisk eller ej. Dvs. möjligheten för kanalväggen att ta upp vattenmolekyler eller inte.  Mätningar av relativ fuktighet, temperatur och daggpunkt har gjorts på tre objekt. Därefter har ånghalter och verkningsgrader beräknats. Med objekt menas småhus där roterande värmeväxlare installerats i ventilationssystemet. Objekten är belägna i Linköping, Stockholm och Norge. Ett beräkningsexempel har ställts upp som visar hur fuktverkningsgraden påverkas av olika fukttillskott. I verkligheten råder dock inte stationära förhållanden för fukttillskottet som är en förutsättning för resultaten på dessa beräkningsexempel.  I denna rapport kommer den skrivande således fram till att fuktåterföring sker även för icke hygroskopiska värmeväxlare. Även att fuktverkningsgraden svarar med en viss tröghet vid återhämtning av ett tillfälligt förhöjt fukttillskott. Fuktverkningsgraden är dock betydande för fukttillskott över ca 1-2 g/m3. / To have a chance to change the trend of increased greenhouse gases are international collaborations necessary. Therefore, the EU through the environmental quality objective of Reduced Environmental Impact sat requirements for maximum allowable emissions of greenhouse gases. Reducing energy use for heating is a step that also reduces emissions of carbon dioxide; which is one of the greenhouse gases. Reducing energy use can be done in several ways, including by increasing the thickness of the insulation or heat recovery from exhaust air. However, these measures should not be uncritically made. The use of a rotating heat exchanger is a means to recover heat from exhaust air. The air then passes a rotor with open channels that rotates around its own axis over to the supply air side. This allows moisture transfer regardless of whether or not the rotor is hygroscopic. That is, the ability of the channel wall to take up water molecules or not.  Measurements of relative humidity, temperature and dew point has been made on three objects. Thereafter steam content and efficiencies was calculated. In other words, the objects are referred to single- ore two-family homes where a rotary heat exchanger is installed in the ventilation system. The objects are located in Linköping, Stockholm and Norway. An example calculation is set up that shows how moisture efficiency is affected by different moisture addition. In reality in which the conditions is not stationary the moisture supplement that is a prerequisite for the results of these calculation examples.  In this report, the writer thus concluded that moisture reversal will occur even for non- hygroscopic heat exchangers. Although the moisture efficiency corresponds with a certain slowness in the recovery of a temporarily elevated moisture addition. Moisture efficiency is significant for moisture supplement of about 1-2 g/m3.
4

Generic design and investigation of solar cooling systems

Saulich, Sven January 2013 (has links)
This thesis presents work on a holistic approach for improving the overall design of solar cooling systems driven by solar thermal collectors. Newly developed methods for thermodynamic optimization of hydraulics and control were used to redesign an existing pilot plant. Measurements taken from the newly developed system show an 81% increase of the Solar Cooling Efficiency (SCEth) factor compared to the original pilot system. In addition to the improvements in system design, new efficiency factors for benchmarking solar cooling systems are presented. The Solar Supply Efficiency (SSEth) factor provides a means of quantifying the quality of solar thermal charging systems relative to the usable heat to drive the sorption process. The product of the SSEth with the already established COPth of the chiller, leads to the SCEth factor which, for the first time, provides a clear and concise benchmarking method for the overall design of solar cooling systems. Furthermore, the definition of a coefficient of performance, including irreversibilities from energy conversion (COPcon), enables a direct comparison of compression and sorption chiller technology. This new performance metric is applicable to all low-temperature heat-supply machines for direct comparison of different types or technologies. The achieved findings of this work led to an optimized generic design for solar cooling systems, which was successfully transferred to the market.

Page generated in 0.1057 seconds