• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 11
  • Tagged with
  • 11
  • 11
  • 7
  • 5
  • 5
  • 5
  • 5
  • 4
  • 4
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Solcellsdrivet FTX-system för miljonprogramshus : Tjärna Ängar, Borlänge / Photovoltaic driven FTX-system for "Miljonprogram" house : Tjärna Änar, Borlänge

Frid, Mikael January 2013 (has links)
Projektet omfattade undersökning och framtagande av ett solcellssystem med förmåga att försörja ett FTX-system i ett flerbostadshus från miljonprogrammet med el. För att kunna bedöma storlek och utformning av komponenter har information tagits genom: Informationssökning via databaser, kurslitteratur och intervjuer Simuleringar av solceller i datorprogrammet PVSYST Modulering av ventilationskanaler i datorprogrammet MagiCAD Syftet var främst att undersöka om det gick att få fram ett teoretiskt fungerande system med avseende på både solceller och ventilation. Beroende på vad resultatet blev skulle även ekonomin i projektet undersökas. Undersökningen visade att det teoretiskt ska gå att installera solceller för elframställning som klarar av att täcka FTX-systemets elbehov på årsbasis. Solcellerna bedöms även producera tillräckligt med el för viss övrig elkrävande utrustning under stora delar av året. Det visade sig även att det skulle gå att få solcellerna ekonomiskt lönsamma om en kalkyltid på 14 år används. Metoden som använts för dessa resultat är noga beskriven och är med små förändringar tillämpbar för ett stort antal byggnader i det svenska byggnadsbeståndet. En viktig slutsats är att om fastighetsägarna kan se 15 år fram i tiden för en investering i solenergi, skulle det innebära inte bara miljömässiga utan även ekonomiska vinster. Det finns redan idag kunnande, teknik och produkter för att utvinna en stor del av fastigheternas elbehov genom solens energi. / The project is a feasibility study of including the installation of solar cells and an FTX ventilation system in the renovation of a Swedish million program multi-family ouse. The question concerns whether the energy production of the PV system can match with the energy consumption of the FTX-system. Input data was obtained from: Databases, literature and interviews. Simulations of photovoltaics modules in the computer program PVSYST Modulation of the vents in the computer program MagiCAD The aim was primarily to investigate whether it was possible to get a theoretical working system. The economy of the project should also be investigated depending on the results. The study showed that it should be theoretically possible to install photovoltaics for electricity generation that is able to cover the FTX system's electricity needs on a yearly basis. The photovoltaics are also expected to produce enough electricity for some other equipment that requires electricity for much of the year. It was also found that it should be possible to get the photovoltaics modules economically viable if a pay-back time of 14 years was used. The method used for these results is thoroughly described and with small changes applicable to a large number of buildings in the Swedish building stock. An important conclusion from the project is that if property owner can see 14 years into the future with an investment in solar energy, there is much to be gained. There are already skills, available technologies and products available in order to recover a large portion of the properties' electricity needs through solar energy.
2

LCC-analys av FTX-system : En jämförelse av centralt- och lägenhetsplacerat / LCC-analysis of HRV-systems : A comparison of central units and apartment units

Appelgren, Jörgen, Kjellström, Fredrik January 2011 (has links)
This report is the result of a thesis conducted at the consulting firm Bjerking AB andis the final part of the Bachelor Programme in Construction Engineering at Universityof Uppsala. The work aims to investigate the costs and how the choice of ventilationsystem affects building projects during a long-term period. This report covers costssuch as investment, maintenance and energy but also how they affect residents andbuilders. Building regulations for energy consumption are expected to be tougher;therefore a comparison of two different heat recovery ventilation systems(HRV-system) was made. One system is based on a centrally placed unit that coversthe whole buildings ventilation through vertical shafts. The second system is based onapartment placed unit that only covers the individual apartment’s ventilation. The unitmakes it possible for the individual user to control the ventilation flow.The method used for comparison of the costs was Life Cycle Cost (LCC). It results inthe total cost during a selected calculation period of 20 years, where yearly basedcosts as energy and maintenance is included. Two housing projects in central Uppsalawere chosen as a reference. They were similar in design but with the two differentsystems of ventilation. A questionnaire was handed out to provide experience fromresidents with apartment units. The results were used in the analysis of the systemsand to determine its pros and cons.Information of costs was collected from different companies and resulted intocustomized spreadsheets to determine the cost per apartment. The result shows thatthe difference in investment is not significant between the systems but is big inmaintenance and energy. The biggest difference is maintenance where the apartmentsystems many service points is increasing the cost. Energy consumption for theapartment system leads to higher energy costs than with a central system, even if thecontrol function is used. The explanation is that a central systems fans have lowerpower usage and the heat recovery is more efficient then an apartment system.The conclusion is that a central system has a lower total cost compared to anapartment system during the calculation period. A reason for choosing the apartmentsystem would be if a need to maximize living space is a priority, and the developingphase of the project is well thought thru.Keywords: LCC-analysis, HRV-systems, Central unit, Apartment unit.
3

Energieffektivisering av Brf. Mörbylund : Förbättringsåtgärder i ett FTX- system / : Action for improvement of a HRV - system

Ourak Pour, Cyrus January 2020 (has links)
Utifrån ett effektiviseringsperspektiv beror en byggnads inomhusklimat på flera enskilda system som tillsammans tillför och balanserar erforderligt energibehov till byggnaden, och samtidigt har de växelverkan med varandra. Systemen är uppvärmningssystem, kylsystem, ventilationssystem, samt styr-och reglersystem som spelar roll av hjärna för de andra. I detta examensarbete är ventilationssystemet i fokus. Numera finns i Sverige olika typer av ventilationssystem. Ett av de vanligaste ventilationssystemen är till-och frånluftsventilation med värmeåtervinning, typ FTX som har två fläktar. Fläkten är en huvudkomponent i ett mekaniskt ventilationssystem och dess skovlar är avgörande för skapande tryck och kan utformas på olika sätt. I Brf. Mörbylund 11–15 i Danderyd kommun tänker föreningen vidta några effektiviseringsåtgärder som ska sänka elkostnaden för 3 stycken luftbehandlingsaggregat. I de allra flesta fall beror hög elförbrukning på gamla fläktar i FTX-system som har höga specifik fläkteleffekt, eller SFP-tal. För att sänka elenergin på aggregaten krävs det att undersöka olika parametrar som gäller aggregaten. Därför behövs mätvärden av parametrar såsom lufttryck, flöde, fläktsverkningsgrad, elförbrukning till fläktar och shuntgrupper som kopplas till luftvärme i aggregaten. Därefter jämförs mätningar över befintliga samt nyinstallerade fläktar, och shuntgrupper. Vid undersökning av de uppmätta parametrarna över befintliga respektive nya komponenter leder det till ett ekonomiskt resultat som speglar konsekvensen av de vidtagna åtgärderna i luftbehandlingsaggregaten. Teorin i denna rapport beskriver de viktiga komponenterna och delarna i ett ventilationssystem, och baseras bland annat på “Projektering av VVS-installationer” av C. Warfvinge & M. Dahlblom. I teoridelen visas flera statistiska fakta kring användning av olika ventilationssystem i Sverige, samt mest ligger fokus på den typen av ventilationssystem som finns i Brf. Mörbylund 11–15, FTXsystem. Under titeln, “Mätmetoder” kommer en del förklaringar av tryckfallberäkning, flöde och fläktdiagram. I teoridelen diskuteras också regler och förutsättningar som presenteras av BBR i detta område som kan hittas i avsnittet, “Myndighetskrav”. Vidare beskrivs det studerade objektet och dess komponenter. I den ekonomiska delen visas två olika kalkylmetoder. Den ena som används av HSB-företag och den andra som väljs av författaren till rapporten för att beräkna möjlig vinst. De är pay-back, och annuitetsmetod. Pay-back-metoden har till nackdel att inte ta hänsyn till låneränta och ekonomisk livslängd vilket däremot är avgörande för annuitetsmetod. Resultatet av annuitetsmetoden visar en negativ summa för kalkylering fastän själva åtgärden är energieffektiv. Det negativa resultatet kan tolkas på olika sätt. Exempelvis kan det bero på olika arbete mellanhänder (mäklaren) som finns mellan föreningen och den första aktören som tillverkar och säljer de önskande komponenterna. I rapporten presenteras och undersökas olika möjliga förklarningar.
4

Energibalansberäkning för flerbostadshus : projekterad energianvändning jämfört med beräknad energianvändning med uppmätta värden för Gävle Strand Etapp 1

Andersson, Robin January 2011 (has links)
Den beräknad mängd energi en byggnad gör av med på ett år visar huruvida den bidrar till ett hållbart samhälle eller inte. AB Gavlegårdarna arbetar inte enbart med att projektera fram förslag till lösningar för framtidens bostäder utan riktar även in sig på sitt nuvarande bestånd när det kommer till energianvändning i flerbostadshus. Gävle Strand Etapp 1 stod klart 2008 med ett bestånd av tolv byggnader som är gestaltade på fyra olika sätt. Alla med olika förutsättningar där främst brukarnas beteende såsom förbrukad mängd tappvarmvatten och hushållsel varierar kraftigt. Under projekteringsfasen anlitades en konsult för att beräkna den köpta energin som dessa bostäder skulle använda och kom fram till en energianvändning på 92 kWh/m2,år. Gavlegårdarnas egna beräkningar som utgick ifrån de verkliga värden som uppmättes för varje lägenhet visade i september 2009 ett medelvärde för hela beståndet som låg på 114 kWh/m2,år. AB Gavlegårdarna vill gå till botten med de problem och den extra kostnad som Gävle Strand Etapp 1 har gett upphov till genom ökad energianvändning, vilket medför att de vill utföra exakta beräkningar på varje byggnads energianvändning. Problemställningen blev därför följande: Hur mycket påverkar FTX-systemets verkningsgrad den totala energiförbrukningen i ett flerbostadshus om systemet inte fungerar som det är tänkt? Kan ett hus bland olika geometriskt utformade hus i ett bestånd anses vara representativ för beståndet, ur energianvändningssynpunkt? Examensarbetet går ut på att genom ett antal U-värdes– och areaberäkningar, ventilations- och luftotäthetsbedömningar, tappvarmvattenanvändning och energibrukarbeteende hos de boende, komma fram till hur mycket en utvald byggnad använder med avseende på specifik energianvändning, med enheten kWh/m2,år. Till författarens hjälp har ett energisimuleringsprogram använts som heter BV2 2010. Resultatet visar att majoriteten av byggnaderna belägna på Gävle Strand Etapp 1 har en högre energianvändning än vad konsultens grundfall visar. Detta på grund av flera faktorer men de främsta orsakerna till den höga energianvändningen i bostäderna är den dåliga temperaturverkningsgraden i FTX-systemets värmeväxlare och brukarbeteendet med en i vissa fall relativt hög användning av tappvarmvatten. / The estimated amount of energy that a building consumes during one year indicates whether it contributes to a sustainable society or not. The communal company, AB Gavlegårdarna , that rents out apartments, works not only with designing proposals for solutions for the future housing , they also work with improving their stock when it comes to energy consumption. The multi-family buildings of Gävle Strand Phase 1 were completed in 2008 with a population of twelve buildings that are shaped in four ways.   During the planning phase a consultant was hired to calculate the how much energy these buildings would have to purchase and came up with an energy use of 92 kWh/m2,year. Gavlegårdarna’s own calculations are based on the actual values obtained for each apartment and in September 2009 and they showed a mean value for the whole stock, which was 114 kWh/m2,year.   AB Gavlegårdarna want to find a solution to the problem and reduce the extra cost that Gävle Strand Phase 1 has given rise through increased use of energy. They want to perform precise calculations on each building's energy use. The problem can be formulated as follows: How much influence does the malfunction of a heat exchanger in a balanced ventilation system have on the total energy consumption in apartment buildings? Can a house among the various geometrically designed houses of a stock be considered to be representative when calculating the energy use of the stock as a whole? The report deals with a number of U-value and area calculations, ventilation and air leakage assessments, domestic hot water use and energy user behavior of the residents, to work out how much a simulated building uses in terms of specific energy, with unit kWh/m2,year. An building simulation program called BV2 2010was utilized. The results show that the majority of the buildings located in Gävle Strand Phase 1 have higher energy consumption than the consultant's basic case. This is due to several factors but the main causes of the high residential energy use is the low temperature efficiency in the FTX-system heat exchanger, the residents’ behavior and in some cases relatively high usage of hot water.
5

Vädringsvanor och energiberäkningar : En enkätstudie kring vädringsvanor och dess påverkan på energiberäkningar i bostäder

Cerps, Adrian, Bergvall, Samuel January 2020 (has links)
Syftet med studien är att öka förståelsen kring vädringsrelaterade beteenden i Sverige samt illustrera vad det har för betydelse för energianvändningen. Ge-nom att samla in enkätsvar från hushåll över hela Sverige samt beräkna ener-giförluster från dessa svar tas förslag fram på vädringstillägg för olika bo-stadstyper.Resultatet visar att småhus berörs betydligt mindre av vädring jämfört med lägenhetshus. Slutsatsen från studien är att alla bostadsbyggnader inte bör ha samma vädringstillägg.
6

Energieffektivisering av flerbostadshus från miljonprogrammet : Beräkningsresultat för åtgärder som minskar värmeförlusterna för ett lamellhus från 1969 i Stockholm

Berhane, Hiyab January 2022 (has links)
Purpose: The purpose of this degree project is to study the energy performance of the apartment building located in Tensta.  This study will propose methods for energy efficiency by calculating the building's need for active heating in its existing condition and then studying and comparing different methods for energy efficiency. Method: To accomplish the purpose of this degree project, a literature study was performed to gather information as well as a case study of the apartment building. In addition to this, relevant calculations were performed to account for the most energy saving measure. Results: The results of this degree project shows that the apartment buildings yearly need for active heating is 193,3 MWh. By changing the current double-glazed windows to new triple-glazed windows the yearly need for active heating decreases by 15%. By installing an HRV-system the yearly need for active heating decreases by 31%. Conclusions: In summary, installing an HRV-system will account for more energy savings compared to changing the current double-glazed windows to new triple-glazed windows. However, this does not mean that installing an HRV-system is a better investment since this study only focuses on the energy savings generated by the different methods and not the cost of the different methods.
7

Värmeåtervinning ur ventilationsluft i äldre flerbostadshus : En jämförande studie av centralt FTX- och FX system / Heat recovery from ventilation air in older apartment buildings : A comparing study of heat recovery between a counterflow heat exchanger and an exhaust air heat pump

Medina, Jean Pierre, Abdulla, Zjikar January 2013 (has links)
En jämförelsestudie har genomförts mellan två värmesystem. Analysen har genomförts med ett flerbostadshus som referensfasighet. Fastigheten är lokaliserad i Södertälje kommun. Analysen går ut på att bestämma vilket värmesystem som är fördelaktigt vid renovering av äldre flerbostadshus med avseende på energi och kostnad. De systemen som har behandlats är ett centralt värmesystem med motströmsvärmeväxlare och ett centralt värmesystem med frånluftsvärmepump. Det centrala värmesystemet (Eq aggregat) är ett centralt från- och tilluftssystem med återvinning (FTX system). Systemet använder en motströmsvärmeväxlare för överföring av värmeenergi mellan från- och tilluften. Det centrala värmesystemet (Energi well) är ett frånluftssystem (FX system) med en ny teknisk lösning. Systemet återvinner värme ur frånluften med hjälp av kondenserande frånluftsvärmpumpar. Värmepumparna finns i en frånluftskammare på vindsvåningen. Den återvunna värmen förs sedan vidare till undercentralen för att värma upp varmvattnet. Analysen har genomförts med hjälp av teoretiska energi- och kostnadsberäkningar, intervjuer och faktainsamlingar.  Energiberäkningarna har bestått av en energibalansberäkning för att få fram den köpta energiförbrukningen. Kostnadsberäkningar har bestått av en livscykelkostnads kalkyl och en kostnads beräkning per producerad värmeenergi. De resulterande värdena för båda värmesystemen har sedan jämförts med varandra. Resultatet visade att värmesystemet Energy well var mest fördelaktig ur både energi och kostnad perspektiv. Den årliga köpta energiförbrukningen var                          lägre än värmesystemet (Eq aggregat) med en motströmsvärmeväxlare. Driftkostnaden var  lägre än Eq aggregat, installations-kostnaderna var  lägre än Eq aggregat och slutlig var livscykelkostnaden  lägre än värme-systemet (Eq aggregat) med motströmsvärmeväxlare. Men underhållskostnaden var  högre än värmesystemet Eq aggregat. Slutsatserna för de teoretiska undersökningarna gav bättre värden för värmesystemet Energy well. Vilket innebär att Energy well är mest fördelaktig utifrån energi- och kostnads perspektiv. Däremot ger värmesystemet med motströmsvärmeväxlare en lägre risk att ett driftfel inträffar i verkligheten. / A comparing study between two different heating systems has been accomplished. The analysis has been conducted with an apartments building as a reference project. The building is located in the municipality of Södertälje. The goal of the analysis is to determine which of the heating system is beneficial for older apartment buildings in terms of energy and cost. The systems that have been treated are a central heating system with a counterflow heat exchanger and a central heating system with an exhaust air heat pump. The central heating system (Eq unit) is a central exhaust- and supply air system with heat recovery. The system uses a counterflow heat exchanger to transfer the heat energy between the exhaust- and supply air. The central heating system (Energy well) is the latest technical solution of a central exhaust air system. The system recovers heat from exhaust air by condensing exhaust air heat pumps. The heat pumps are in an exhaust air chamber and it´s placed on the attic floor. The recovered heat energy sends then to the mechanical room to heat up the water system. The analysis has been accomplished by using theoretical energy- and cost calculations, interviews and data collection. The energy calculations are based on an energy balance equation to determine the bought energy consumption. The cost calculation is based on a life cycle cost equation and a cost equation per produced heat energy. The results of both heating systems have been compared with each other. The results showed that the heating system Energy well was most beneficial in both energy and cost perspective. The annual consumption of bought energy was                          lower each year than the heating system (Eq unit) with a counterflow heat exchanger. The operating costs of the system were  lower than Eq unit, the installation costs were  lower than Eq unit and final was the life cycle cost  less than the heating system (Eq unit) with counterflow heat exchanger. But the service cost was  higher than the heating system Eq unit. The conclusion of the theoretical investigations gave better values ​​for the heating system Energy well. This means than Energy well is most beneficial from the energy and cost perspectives. Contrariwise has the heating system with counterflow heat exchanger a lower risk of an operational failure to occur in reality.
8

Energieffektivisering av miljonprogrammet i samband med våningspåbyggnad : Energisimulering i IDA ICE / Energy efficiency of the milion program in conjuction with story extension : Energy simulation usin IDA ICE

Aziz, Pola, Huynh, Kelvin January 2018 (has links)
En stor del av alla bostäder som byggdes mellan 1965-1974 brukar betecknas miljonprogrammet. Efter 40-50 års förbrukning har byggnaderna uppnått sin tekniska livslängd och är därför i behov av renovering. Detta samtidigt som bostadsbristen återstår och energikraven från myndigheter blir allt strängare i syfte att reducera bostadssektorns energianvändning samt för att uppnå ett hållbart samhälle.  Studien är baserad på ett flerbostadshus, Barytongatan 4 som är belägen i Göteborg och som är en del av projektet Kaverös etapp II. I denna studie undersöks energibesparingsåtgärder i samband med våningspåbyggnad och de regelverk som gäller vid om- och tillbyggnad enligt BBR och PBL. I simuleringsprogrammet IDA ICE kunde olika energibesparingsåtgärder studeras. Resultatet från varje enskild åtgärd och en sammansättning av dessa jämfördes därefter med den befintliga byggnadens energideklaration och statisk. Studien är koncentrerad till energisimuleringar och behandlar inga ekonomiska beräkningar. Rapporten fastställer att en våningspåbyggnad, som ökar byggnadsvolymen, är en tillbyggnad samt att allt för stora åtgärder i en befintlig byggnad klassas som en ombyggnad enligt BBR och PBL. Studien berör energibesparingsåtgärder gällande FX-system, FTX-system, balkonginglasning och solpaneler på tak. Resultatet visar att med endast få ingrepp i referenshuset, i enlighet med regelverken, kunde energianvändningen reduceras från 147 kWh/m² till 104,8 kWh/m², vilket motsvarar 28,8 procent. / A majority of houses that were built during the years 1965-1974 is usually referred to as the million program. After 40-50 years of use, the buildings have reached their technical life expectancy and need to be renovated. At the same time, the lack of housing shortage continues to exist while energy requirements from the government are becoming increasingly strict. The government maintains and run a strict policy to reduce the energy consumption of the housing sector in hope of achieving a more sustainable society. The study is based on a multi-family house located in Kaverös, Gothenburg at Barytongatan 4, which is part of the Kaverös Stage II project. In this study, energy conservation measures are investigated in connection with story extension and the applicable regulations when it comes to rebuilding and upgrading in accordance with BBR and PBL. Using the IDA ICE simulation program, different energy conservation measures could be studied. The result of each individual energy conservation measure, and a combination of these were then compared with the existing building's energy declaration and static. This study is limited to energy calculation and no financial calculations are presented The result shows that only a few interventions in the reference housing, according to the regulations BBR and PBL, can affect the energy consumption and reduce it from 147 kWh/m² to 104.8 kWh/m², which corresponds to 28.8 percent.
9

Skiljer sig energiberäkningarna i projekteringsstadiet från energiberäkningarna i relationshandlingarna?

Ingarsson, Ellen, Sköld, Ellen January 2022 (has links)
To reduce the emissions from energy use, high demands are set on new buildings. Studies have shown big differences between predicted and actual energy performance. This gap makes it more difficult to reduce the energy use in buildings. The aim of this study is to discover if deviations occur before the building is put into use, and if it does, discuss the reasons for that.  In this study, energy performance for 20 multi-family houses have been compared between the early design stage and the production stage. The result of this study is that there are no major differences in energy use between the different documents. On the other hand, there are big differences in some of the parameters that the energy use is dependent on. The reasons of this are discussed later in this thesis. None of the investigated buildings had the same value of energy performance in the production stage as in the early stage. The parameter that has shown the greatest difference is space heating and hot water recirculation. The biggest correlation was found between the energy required by the fans and the buildings total energy use.
10

Inneklimat i kontorslokaler : Fallstudie av belysning och ventilation i kontor i Västerås

Kamil, Ayhan, Aljanabi, Tabarek January 2021 (has links)
The office environment is an important part of the workers’ performance and need therefore to be designed in a pleasant and functional way. The problem is not that today’s offices do not function but rather that these need to be improved to achieve better work results. Lighting and ventilation are big parts of the office environment. In this project will three offices be examined, and these are Archus, WSP and Sweco. Purpose: This study is done to find improvement measures for these three offices based on the examination of the light and ventilation conditions. The improvements that will be suggested are mainly based on a survey but also a study on how these two factors affect the employees’ performances. Method: To perform this project was a literature study, a case study and measurement of illuminance used. A survey om how the employees experience the office environment were also conducted. Drawings provided by the office managers were used to perform calculations of the airflow. Results: The survey shows that 73.5 percent of the 68 people who answered the survey feel comfortable in the current design of the offices. The rest feel that they lack privacy and a quiet environment. In addition, 82.4 percent are happy with the lighting situation and 69.1 percent with the air quality. Archus, WSP and Sweco all meet the required guidelines set for illuminance in an office with certain deficiency. For ventilation do Archus and Sweco meet the minimum requirements for airflow, but there are small differences between the dimensioned airflow and the minimum requirement for WSP. Conclusions: The conclusion of this study is that the three studied offices lack seclusion which affects the office workers’ ability to work. The current lighting, and the ventilation in smaller rooms also contribute worsened working conditions. Good lighting conditions is required to achieve good work results. The same applies to ventilation where the air flow is deficient in certain rooms and should be regulated. / Kontorsmiljön är en viktig del i arbetarnas prestation och ska därför utformas på ett trivsamt och funktionellt sätt. Problematiken är inte att dagens kontor inte fungerar utan att dessa kan förbättras för att uppnå goda arbetsresultat. Belysning och ventilation är stora delar inom ämnet och kontoren som undersöks i detta arbete är Archus, WSP och Sweco.  Syftet med studien är att ta fram förbättringsåtgärder för tre kontorslokaler utifrån en undersökning avseende belysnings- och ventilationsförhållanden. Förbättringsförslaget bygger främst på en enkät men även en studie om hur de två faktorer spelar in i medarbetarnas presterande.  För att utföra studien tillämpades ett antal olika metoder däribland en litteraturstudie för att sätta grund till arbetet, en fallstudie där ett studiebesök till de undersökta kontoren och mätningar utfördes. Även en enkät om hur medarbetarna upplever sina kontorsmiljöer gjordes. Ritningar som tillhandahölls av ansvariga på kontoren tillämpades för att utföra beräkningar av luftflödet.  I resultat visar enkäten att 73,5% av de 68 personer som besvarade enkäten känner sig bekväma i den nuvarande utformningen men att resterande att de saknar avskildhet och tystare miljö. Utöver det trivs 82,4% med belysningen och 69,1% med luftkvalitén i dagsläget.  Archus, WSP och Sweco uppfyller de riktvärden som ställs för belysningsstyrka i kontorslokaler med vissa avvikelser. För ventilation uppfyller Archus och Sweco minimikraven för luftflödet men för WSP förekommer det skillnader mellan minimikravet och det dimensionerade luftflödet.  Diskussionen visar att vid utförandet av mätningar var det svårt att anpassa omgivningen efter önskemål vilket medförde att vissa mätvärden avviker från verkligheten. Även för beräkning av ventilation uppstod oförväntade svårigheter som att tillgång till egna instrument för luftflödesmätning saknades samt brister i ritningar.  Slutsatserna som dras för arbetet är att de tre kontoren saknar avskildhet vilket påverkar kontorsarbetarnas arbetsförmåga. Även den nuvarande belysningen samt ventilationen i mindre rum bidrar med försämrade arbetsförhållanden. För att uppnå ett gott arbetsresultat krävs god belysning i verksamheten. Samma gäller för ventilation där luftflödet brister i vissa rum och bör regleras.

Page generated in 0.0316 seconds