• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 31
  • 18
  • 5
  • 2
  • 1
  • 1
  • Tagged with
  • 59
  • 20
  • 14
  • 12
  • 8
  • 7
  • 7
  • 7
  • 6
  • 6
  • 6
  • 5
  • 5
  • 5
  • 5
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Análise da mudança de cor em concretos submetidos a altas temperaturas como indicativo de temperaturas alcançadas e da degradação térmica / Color Change Analysis in Concretes Exposed to High Temperatures as Indicative of Reached Temperatures and Thermal Degradation

Wendt, Sheila Cristina January 2006 (has links)
A avaliação de uma estrutura danificada por incêndios usualmente inicia por observações visuais do concreto, incluindo sua mudança de cor. A mudança de cor observada no concreto exposto a altas temperaturas persiste após seu resfriamento, constituindo-se em uma ferramenta importante para uma avaliação preliminar do nível de deterioração do concreto, pois essas mudanças podem ser relacionadas com as temperaturas as quais o mesmo foi exposto. Com o objetivo de avaliar as mudanças de cor e a degradação térmica de concretos potencialmente encontrados em estruturas no estado, foram estudados concretos de resistência convencional, moldados com materiais usualmente empregados no RS. Foram utilizadas três relações água/cimento, empregando-se o cimento CPIV, agregado graúdo granítico e basáltico. Os espécimes moldados foram submetidos às temperaturas de 200°C, 400°C, 600°C e 900°C, utilizando-se como base uma taxa de aquecimento baseada na curva padrão “Temperatura-Tempo”. Após o aquecimento, os espécimes foram resfriados lentamente, no interior do forno, e bruscamente, com aspersão de água. A degradação térmica do concreto foi avaliada através de ensaios de resistência à compressão, módulo de elasticidade e ultra-som. Para a avaliação das mudanças de cor foi utilizada metodologia colorimétrica, método mais consistente do que uma avaliação visual subjetiva. Observou-se queda de resistência à compressão e do módulo de elasticidade do concreto, conforme o aumento da temperatura de exposição. O ensaio de ultra-som mostrou-se bastante efetivo para detectar micro-fissuração do concreto, apresentando fatores de redução da velocidade de propagação mais semelhantes aos fatores de redução do módulo de elasticidade do que da resistência à compressão, mostrando a sensibilidade e potencialidade do método. As maiores diferenças colorimétricas foram obtidas nos concretos expostos às temperaturas mais altas, acima de 600°C, cujos níveis de percepção podem ser classificados como facilmente distinguíveis e muito grandes, o que pôde ser confirmado pela análise visual dos concretos, na qual foi observado o surgimento de uma cor amarelada. Considera-se, portanto, viável a identificação dos níveis de temperatura de exposição do concreto através das diferenças colorimétricas, especialmente para altas temperaturas de exposição, e, portanto, de maior interesse, já que levam a níveis de degradação mais acentuados. / The assessment of fire damaged concrete structures usually starts with visual observation of concrete, including his color change. The observed color change in high temperatures exposed concrete remains after cooling, consisting in a important tool for a preliminar assessment of concrete deterioration degree, therefore this changes could be related with the exposed temperatures. With the objective of assessing the color changes and thermal degradation of concretes potentially finding out in state’s structures, it was studied in this work normal-strength concretes made with materials usually finding in RS state. The concretes were made with three w/c ratio, with Pozzolanic cement (CPIV), granitic e basaltic coarse aggregate. The molded specimens were subjected to temperatures of 200°C, 400°C, 600°C e 900°C, with utilization of the standard fire curve (ISO 834). After heating, the specimens were allowed to a slow cool in the furnace, and quickly with water spread. The concrete thermal degradation was assessed with compressive strength test, elasticity modulus and pulse velocity measurements. The color changes was assessed by colorimetric methodology, a more consistent method than a subjective visual assessment. It was observed concrete loss of compressive strength and elasticity modulus with de increment of the exposure temperature. The pulse velocity test showed itself as a very effective for detecting concrete micro-cracks, showing reducing factors, as exposure temperature, more likely the elasticity modulus reducing factors than the compressive strength, indicating method sensibility and potentiality. The larger colorimetric differences were obtained on concretes exposed at higher temperatures, above 600°C, witch perceptions levels can be confirmed by concretes visual analyses, where was observed the appeared of a buff color. Can be consider, thus, viable to make the identification of concrete exposed temperatures levels through colorimetric differences, specially for higher exposure temperatures, end, thus, of major interest, since they conduce to more accentuated degradation levels.
12

Efeito de tratamentos térmicos na resistência à tração e na dureza Vickers do Ti c.p. e da liga Ti-6Al-4V obtidos por fundição odontológica /

Rocha, Sicknan Soares da. January 2002 (has links)
Orientador: Gelson Luis Adabo / Banca: Luís Geraldo Vaz / Banca: Guilherme Elias Pessanha Henriques / Resumo: O objetivo desta investigação foi determinar se os tratamentos térmicos podem alterar a resistência à tração e a dureza Vickers do Ti c.p. e da liga Ti-6Al-4V. Trinta corpos-de-prova na forma de halteres com 3,0 mm no segmento central e 42 mm de comprimento, obtidos por meio de uma matriz de alumínio, foram fundidos no sistema Rematitan. Os corpos-de-prova de Ti c.p. e Ti-6Al-4V foram divididos aleatoriamente em três grupos de 10 cada, e submetidos às seguintes condições de tratamento térmico: (1) controle; (2) T1 - aquecimento a 750ºC/2 h; (3) T2 - recozimento a 955ºC/1 h e envelhecimento a 620ºC/2 h. Ambos, aquecimento e resfriamento, foram realizados em atmosfera controlada de argônio. O ensaio de tração foi efetivado na máquina de testes mecânicos MTS modelo 810 à velocidade de 1,0 mm/min. Após o teste de tração uma das extremidades do corpo-de-prova foi embutida em resina acrílica, regularizada e polida antes da medida da dureza Vickers no durômetro Micromet 2100. As médias de resistência à tração e dureza Vickers foram comparadas estatisticamente usando o teste não-paramétrico de Kluskall-Wallis. Nos grupos de Ti c.p. não foram observadas diferenças significativas na resistência à tração, entretanto, na dureza Vickers os resultados do grupo T2 foram significativamente maiores que os outros grupos, que se mostraram iguais entre si. Na liga Ti-6Al-4V os grupos controle e T1 revelaram igualdade estatística em relação à resistência à tração, e significativamente superiores ao grupo T2. Quanto à dureza Vickers, diferenças estatisticamente significantes foram observadas entre os três grupos de tratamento térmico: T2>T1>controle. Não foi observada correlação entre as propriedades de resistência à tração e dureza Vickers. ...(Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The aim of this investigation was to determine whether heat treatments could change the tensile strength and Vickers hardness of CP Ti and Ti-6Al-4V alloy castings. Thirty dumbbell rods, 3.0 mm in diameter at the central segment and 42 mm in length, obtained from an aluminum matrix, were cast for each metal in the Rematitan system. The specimens of CP Ti and of alloy Ti-6Al-4V, were divided randomly into three groups of ten each; then submitted to the following heat treatments: (1) control group, without heat treatment; (2) T2 - heat at 750ºC for 2 h; (3) annealing at 955ºC for 1 h and aged at 620ºC for 2 h. The heat treatments, as well as the cooling process were conducted in the furnace with argon atmosphere. The tensile strength was measured by means of a universal testing machine, MTS model 810, at a strain of 1.0 mm/min. After the tensile testing the specimens were embedded in acrylic resin, grounded and polished prior to hardness measurements, using the Vickers tester Micromet 2100. The means and standard deviations of tensile strength and Vickers hardness were statistically compared using Kruskal-Wallis non-parametric test at a=0.05 significance level. In CP Ti groups, no statistically significant differences in tensile strength were observed; however, in Vickers hardness the results of group T2 were significantly higher than the other groups, which showed similar mean values among themselves. In Ti-6Al-4V alloy, the control and T1 groups revealed statistically higher tensile strength when compared to T2 group, with no significant difference between control and T1 group. Regarding Vickers hardness, statistically significant differences were observed among the three heat-treatment groups: T2>T1>control...(Complete abstract, click electronic access below) / Mestre
13

Efeito do tratamento térmico nos fios ortodônticos de aço inoxidável

Kasbergen, Geraldo Francisco [UNESP] 27 November 2007 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:27:54Z (GMT). No. of bitstreams: 0 Previous issue date: 2007-11-27Bitstream added on 2014-06-13T18:32:11Z : No. of bitstreams: 1 kasbergen_gf_me_araca.pdf: 1206449 bytes, checksum: d032f277224382ffaa352a9929e1135b (MD5) / O objetivo deste trabalho foi avaliar o efeito do tratamento térmico (ou revenido) nos fios ortodônticos de aço inoxidável de Cromo Níquel (CrNi). Foram utilizados 40 arcos das espessuras 0.014”(0,35mm), 0.016”(0,40mm), 0.018”(0,45mm) e 0.020”(0,50mm). Os arcos foram divididos nos grupos sem e com tratamento térmico e, posteriormente, mensurados nas regiões anterior e posterior por meio do “software” AutoCad 2000 antes e após os ensaios mecânicos de compressão e tração por meio da máquina de ensaio universal EMIC. Os resultados foram submetidos à análise estatística com teste de multivariância ANOVA em nível de 5% (p<0,05). Diante da metodologia utilizada neste estudo, pode-se concluir que os arcos ortodônticos tratados termicamente apresentam suaves modificações transversais na região anterior e maiores aumentos transversais na região posterior, porém, provavelmente, sem relevância clínica. Os arcos sem e com tratamento térmico submetidos à força de compressão não apresentaram alterações transversais significantes nas regiões anterior e posterior. Nos arcos sem tratamento térmico submetidos à força de tração ocorreram aberturas mais acentuadas na região anterior nos arcos 0.020”. Na região posterior, a abertura proporcionada pela tração ocorreu com maior intensidade nos arcos sem tratamento térmico. Os arcos com tratamento térmico submetidos à força de tração não alteraram a distância transversal na região anterior. Nos arcos tratados termicamente constatou-se uma maior estabiidade, principalmente quando submetidos à tração ou à abertura. / The aim of this study was to evaluate the effect of heat treatment in orthodontic wires of Chrome Nickel (CrNi) stainless steel. 40 arches of 0.014 (0,35 mm), 0.016 (0.40 mm), 0.018 (0.45 mm) and 0.020 (0.50 mm) were used. The arches were divided 2 groups: with and without heat treatment and then measured in anterior and posterior regions using AutoCad 2000 software before and after tension and compression tests, using universal testing machine EMIC. The results were submitted to ANOVA multivariance test for statistical analysis with level of 5% (p<0.05). Through the methodology used in this study it can be concluded that the orthodontic arches with heat treatment presented soft transversal changes in the anterior region and larger transversal increases in the posterior region, probably without clinical relevance. The arches with and without heat treatment submited to compression force did not show significant transversal changes in the anterior and posterior regions. The arches 0.020 without heat treatment submited to traction force presented the largest increases in width in the anterior region. Traction force at posterior region led to arch openning with greater intensity in arches without heat treatment. The arches with heat treatment submited to traction force didn’t change the transversal distance in the anterior region. It was found that arches with heat treatment had greater stability, especially when submitted to traction or opening forces.
14

Análise da mudança de cor em concretos submetidos a altas temperaturas como indicativo de temperaturas alcançadas e da degradação térmica / Color Change Analysis in Concretes Exposed to High Temperatures as Indicative of Reached Temperatures and Thermal Degradation

Wendt, Sheila Cristina January 2006 (has links)
A avaliação de uma estrutura danificada por incêndios usualmente inicia por observações visuais do concreto, incluindo sua mudança de cor. A mudança de cor observada no concreto exposto a altas temperaturas persiste após seu resfriamento, constituindo-se em uma ferramenta importante para uma avaliação preliminar do nível de deterioração do concreto, pois essas mudanças podem ser relacionadas com as temperaturas as quais o mesmo foi exposto. Com o objetivo de avaliar as mudanças de cor e a degradação térmica de concretos potencialmente encontrados em estruturas no estado, foram estudados concretos de resistência convencional, moldados com materiais usualmente empregados no RS. Foram utilizadas três relações água/cimento, empregando-se o cimento CPIV, agregado graúdo granítico e basáltico. Os espécimes moldados foram submetidos às temperaturas de 200°C, 400°C, 600°C e 900°C, utilizando-se como base uma taxa de aquecimento baseada na curva padrão “Temperatura-Tempo”. Após o aquecimento, os espécimes foram resfriados lentamente, no interior do forno, e bruscamente, com aspersão de água. A degradação térmica do concreto foi avaliada através de ensaios de resistência à compressão, módulo de elasticidade e ultra-som. Para a avaliação das mudanças de cor foi utilizada metodologia colorimétrica, método mais consistente do que uma avaliação visual subjetiva. Observou-se queda de resistência à compressão e do módulo de elasticidade do concreto, conforme o aumento da temperatura de exposição. O ensaio de ultra-som mostrou-se bastante efetivo para detectar micro-fissuração do concreto, apresentando fatores de redução da velocidade de propagação mais semelhantes aos fatores de redução do módulo de elasticidade do que da resistência à compressão, mostrando a sensibilidade e potencialidade do método. As maiores diferenças colorimétricas foram obtidas nos concretos expostos às temperaturas mais altas, acima de 600°C, cujos níveis de percepção podem ser classificados como facilmente distinguíveis e muito grandes, o que pôde ser confirmado pela análise visual dos concretos, na qual foi observado o surgimento de uma cor amarelada. Considera-se, portanto, viável a identificação dos níveis de temperatura de exposição do concreto através das diferenças colorimétricas, especialmente para altas temperaturas de exposição, e, portanto, de maior interesse, já que levam a níveis de degradação mais acentuados. / The assessment of fire damaged concrete structures usually starts with visual observation of concrete, including his color change. The observed color change in high temperatures exposed concrete remains after cooling, consisting in a important tool for a preliminar assessment of concrete deterioration degree, therefore this changes could be related with the exposed temperatures. With the objective of assessing the color changes and thermal degradation of concretes potentially finding out in state’s structures, it was studied in this work normal-strength concretes made with materials usually finding in RS state. The concretes were made with three w/c ratio, with Pozzolanic cement (CPIV), granitic e basaltic coarse aggregate. The molded specimens were subjected to temperatures of 200°C, 400°C, 600°C e 900°C, with utilization of the standard fire curve (ISO 834). After heating, the specimens were allowed to a slow cool in the furnace, and quickly with water spread. The concrete thermal degradation was assessed with compressive strength test, elasticity modulus and pulse velocity measurements. The color changes was assessed by colorimetric methodology, a more consistent method than a subjective visual assessment. It was observed concrete loss of compressive strength and elasticity modulus with de increment of the exposure temperature. The pulse velocity test showed itself as a very effective for detecting concrete micro-cracks, showing reducing factors, as exposure temperature, more likely the elasticity modulus reducing factors than the compressive strength, indicating method sensibility and potentiality. The larger colorimetric differences were obtained on concretes exposed at higher temperatures, above 600°C, witch perceptions levels can be confirmed by concretes visual analyses, where was observed the appeared of a buff color. Can be consider, thus, viable to make the identification of concrete exposed temperatures levels through colorimetric differences, specially for higher exposure temperatures, end, thus, of major interest, since they conduce to more accentuated degradation levels.
15

Substituição da eletrotermia por gases combustíveis no setor industrial / Substitution of Electrotherm by Combustible Gases in the Industrial Sector

Flávio Fernandes 02 June 2008 (has links)
Este trabalho analisa a viabilidade técnica, econômica e financeira para substituir a eletrotermia resistiva pela queima direta de gases combustíveis, sendo eles o gás natural (GN) e o gás liquefeito de petróleo (GLP). Para atingir este objetivo, faz-se um levantamento da presença da eletrotermia nos processos produtivos de algumas indústrias localizadas na grande São Paulo; propõe uma metodologia para a escolha das indústrias com maior concentração na região geográfica estudada com o uso do CEP, código CNAE, histórico do setor e número de funcionários; desenvolve uma metodologia para avaliar o impacto da substituição da eletrotermia na qualidade da energia elétrica resultante da mudança, com o foco no fator de potência e harmônicas; elabora um procedimento para se fazer o levantamento de campo, com a identificação da matriz de usos finais da energia, as características dos processos que utilizam a eletrotermia, analisando as limitações desta substituição, os diferentes custos operacionais de acordo com as tarifas da concessionária e formas de contratação da energia. Este trabalho identifica as políticas e programas governamentais existentes para a eficiência energética e faz análise crítica das mesmas, como também sugere alterações para facilitar a mudança do energético utilizado (cerne da substituição da eletrotermia), buscando aumentar a sinergia entre estes programas e as políticas, com o intuito de apresentar a substituição da eletrotermia como um grande potencial para a redução do consumo de energia elétrica no Brasil e no uso mais racional dos gases combustíveis. / This work analyzes the technical, economical and financial viability to substitute the resistive electrotherm for the direct combustion of fuel gases, such as natural gas (NG) and liquefied gas of petroleum (LGP). In order to do so, a study of the electrotherm presence in the productive process of some industries located in The Great São Paulo has been done; a methodology to choose industries concentrated mainly in the above mentioned geographic region by Zip Code, ISIC Code, historic of the sector and number of employees was proposed; a methodology was developed to evaluate the impact of the electrotherm substitution on the quality of the remaining electric energy, after the change, focusing on power factor and harmonics; a procedure for the field study was also proposed, identifying the final uses of the energy, the characteristics of the processes which use electrotherm, analyzing the limitations of these substitutions, the different operational costs according to the local concessionaries and how the energy has been contracted. This work identifies the existing policies and governmental programs for energetic efficiency and makes a critical analysis of them, as well as suggesting alternatives to the current energy model (core of electrotherm substitution), seeking to improve the synergy between policies and programs, in an attempt to show the electrotherm substitution as a huge potential to reduce the electric energy consumption in Brazil and a more rational use of fuel gases.
16

Análise da mudança de cor em concretos submetidos a altas temperaturas como indicativo de temperaturas alcançadas e da degradação térmica / Color Change Analysis in Concretes Exposed to High Temperatures as Indicative of Reached Temperatures and Thermal Degradation

Wendt, Sheila Cristina January 2006 (has links)
A avaliação de uma estrutura danificada por incêndios usualmente inicia por observações visuais do concreto, incluindo sua mudança de cor. A mudança de cor observada no concreto exposto a altas temperaturas persiste após seu resfriamento, constituindo-se em uma ferramenta importante para uma avaliação preliminar do nível de deterioração do concreto, pois essas mudanças podem ser relacionadas com as temperaturas as quais o mesmo foi exposto. Com o objetivo de avaliar as mudanças de cor e a degradação térmica de concretos potencialmente encontrados em estruturas no estado, foram estudados concretos de resistência convencional, moldados com materiais usualmente empregados no RS. Foram utilizadas três relações água/cimento, empregando-se o cimento CPIV, agregado graúdo granítico e basáltico. Os espécimes moldados foram submetidos às temperaturas de 200°C, 400°C, 600°C e 900°C, utilizando-se como base uma taxa de aquecimento baseada na curva padrão “Temperatura-Tempo”. Após o aquecimento, os espécimes foram resfriados lentamente, no interior do forno, e bruscamente, com aspersão de água. A degradação térmica do concreto foi avaliada através de ensaios de resistência à compressão, módulo de elasticidade e ultra-som. Para a avaliação das mudanças de cor foi utilizada metodologia colorimétrica, método mais consistente do que uma avaliação visual subjetiva. Observou-se queda de resistência à compressão e do módulo de elasticidade do concreto, conforme o aumento da temperatura de exposição. O ensaio de ultra-som mostrou-se bastante efetivo para detectar micro-fissuração do concreto, apresentando fatores de redução da velocidade de propagação mais semelhantes aos fatores de redução do módulo de elasticidade do que da resistência à compressão, mostrando a sensibilidade e potencialidade do método. As maiores diferenças colorimétricas foram obtidas nos concretos expostos às temperaturas mais altas, acima de 600°C, cujos níveis de percepção podem ser classificados como facilmente distinguíveis e muito grandes, o que pôde ser confirmado pela análise visual dos concretos, na qual foi observado o surgimento de uma cor amarelada. Considera-se, portanto, viável a identificação dos níveis de temperatura de exposição do concreto através das diferenças colorimétricas, especialmente para altas temperaturas de exposição, e, portanto, de maior interesse, já que levam a níveis de degradação mais acentuados. / The assessment of fire damaged concrete structures usually starts with visual observation of concrete, including his color change. The observed color change in high temperatures exposed concrete remains after cooling, consisting in a important tool for a preliminar assessment of concrete deterioration degree, therefore this changes could be related with the exposed temperatures. With the objective of assessing the color changes and thermal degradation of concretes potentially finding out in state’s structures, it was studied in this work normal-strength concretes made with materials usually finding in RS state. The concretes were made with three w/c ratio, with Pozzolanic cement (CPIV), granitic e basaltic coarse aggregate. The molded specimens were subjected to temperatures of 200°C, 400°C, 600°C e 900°C, with utilization of the standard fire curve (ISO 834). After heating, the specimens were allowed to a slow cool in the furnace, and quickly with water spread. The concrete thermal degradation was assessed with compressive strength test, elasticity modulus and pulse velocity measurements. The color changes was assessed by colorimetric methodology, a more consistent method than a subjective visual assessment. It was observed concrete loss of compressive strength and elasticity modulus with de increment of the exposure temperature. The pulse velocity test showed itself as a very effective for detecting concrete micro-cracks, showing reducing factors, as exposure temperature, more likely the elasticity modulus reducing factors than the compressive strength, indicating method sensibility and potentiality. The larger colorimetric differences were obtained on concretes exposed at higher temperatures, above 600°C, witch perceptions levels can be confirmed by concretes visual analyses, where was observed the appeared of a buff color. Can be consider, thus, viable to make the identification of concrete exposed temperatures levels through colorimetric differences, specially for higher exposure temperatures, end, thus, of major interest, since they conduce to more accentuated degradation levels.
17

Índices de conforto térmico e adaptabilidade de fêmeas bubalinas em pastejo no Agreste de Pernambuco

COSTA, Lígia Alexandrina Barros da 28 February 2007 (has links)
Submitted by (edna.saturno@ufrpe.br) on 2017-04-26T15:36:43Z No. of bitstreams: 1 Ligia Alexandrina Barros da Costa.pdf: 401629 bytes, checksum: 41474d2518470019394d748cf22e8e59 (MD5) / Made available in DSpace on 2017-04-26T15:36:43Z (GMT). No. of bitstreams: 1 Ligia Alexandrina Barros da Costa.pdf: 401629 bytes, checksum: 41474d2518470019394d748cf22e8e59 (MD5) Previous issue date: 2007-02-28 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / The objectives of this work were to determine the best indexes of thermal comfort for buffaloes and to estimate the upper critical levels of these indexes, based on the physiologic parameters. The experiment was carried from february to april at agreste region of the Pernambuco state. Physiologic parameters as rectal temperature (Tr), breathing frequency (Fr) and skin temperature (Tp) were measured thrice to every week in the periods of the morning and afternoon. Sweating rate (Tsud) was measured in the afternoon, once to every week. Correlation and regression analysis were made using data obtained from ten buffaloes: five heifers and five pregnant buffaloes cows. The results showed that Fr was better than rectal temperature (Tr) and sweating rate (Tsud) as an indicator of heat stress for pregnant bufalloes cows. ITGU was better than ITU, based on Fr. Based on Tr the estimated upper critical levels of temperature-humidity index (ITU) and black globe temperature and humidity index (ITGU) were 79,5 and 89,1, respectively, for the heifers and based on breathing frequency those estimated critical levels were, respectively, 77 and 83. Based on Fr the estimated critical values of ITU and ITGU were 79 and 81, respectively, for the pregnant buffaloes cows. / O objetivo deste trabalho foi determinar os melhores índices de conforto térmico para bubalinos estimando seus valores críticos, baseando-se nos parâmetros fisiológicos. O experimento foi conduzido de fevereiro a abril na região agreste de Pernambuco. Os parâmetros fisiológicos temperatura retal (Tr), freqüência respiratória (Fr) e temperatura de pele (Tp) foram avaliados três vezes por semana nos períodos da manhã e da tarde e a taxa de sudação (Tsud) foi mensurada apenas à tarde, uma vez a cada semana. As medidas para análise de correlação entre as variáveis e regressão foram obtidas de dez animais: cinco novilhas e cinco búfalas em gestação. Os resultados obtidos evidenciaram, nas búfalas em gestação, que Fr foi o melhor indicador de estresse térmico que temperatura retal (Tr) e taxa de sudação (Tsud). O ITGU revelou ser o melhor índice que o ITU, baseando-se na Fr. Com base na Tr foram estimados valores críticos de índice de temperatura e umidade (ITU) e índice de temperatura de globo e umidade (ITGU) iguais a 79,5 e 89,1, respectivamente, para as novilhas. Baseando-se na Fr esses valores foram, respectivamente, 77 e 83. Para as búfalas, considerando a Fr, os valores críticos de ITU e ITGU foram 79 e 81, respectivamente.
18

Modelagem e teste de condutividade termica em placa de gesso e fibra vegetal, Mauritia vinifera martius, para uso na construção civil / Modeling and conductivity thermical test in plate of plaster vegetal faber, Mauritia vinifera martius, to be used in civil construction

Lima, João Pinto 12 August 2018 (has links)
Orientador: Kamal Abdel Radi Ismail / Dissertação (mestrado profissional) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecanica / Made available in DSpace on 2018-08-12T18:11:18Z (GMT). No. of bitstreams: 1 Lima_JoaoPinto_M.pdf: 3645303 bytes, checksum: 383a85f77a68b7f7e9e69a704c169634 (MD5) Previous issue date: 2005 / Resumo: O conforto ambiental nas edificações é buscado pelos arquitetos como requisito básico na arte de projetar. Estudos de volumetria, o dimensionamento de aberturas, a modelagem dos espaços, o estudo da direção das correntes de ar e a insolação são alguns pressupostos que devam ser observados quando da análise projectual. Ao desenvolvermos a pesquisa sobre material compósito para uso na construção civil utilizando Argamassa de Gesso e Fibra Vegetal, Mauritia vinifera Martius - Palmeira de Buriti-ivan, tem-se como objetivo obter um novo material que possa ser utilizado como revestimento ou elementos de vedação, agregando a este propriedade que conduza à baixa condutividade térmica. A partir da mistura homogeneizada da argamassa de gesso e fibras vegetais em proporção titulada foram produzidas amostras do compósito que submetidas ao Teste do Fio Quente Paralelo determinação da condutividade térmica pela propagação de ondas isotérmicas de calor. Foram determinantes na pesquisa, os estudos da titulação entre as partes agregadas, o teor de umidade, o índice de vazios e a porosidade das amostras. Os testes indicaram que o melhor desempenho obteve-se com as misturas de titulações de 0 % a 35 % de fibra vegetal, M.v.M para o intervalo de tempo compreendido entre 640 a 1280 minutos. / Abstract: The indoor comfort in buildings in researched by the architets as a basic criterion in the art of architecting. Volumetria studies, measuring of archs, space desing, studies of the air commuting as well as insolation are some of the asects which must be focused by the acting of projecting. by the time we developed the research on composite material to be used in the civil enginearing using gipsy and natural fibers, Maurítia vinifera Martius - buriti palm tree, we had as a main gool to obtoin a men material which could the used as a revestiment or elements of tapping, adding to it properties that conduct to a low thermic concdutivity. Based on the homogeous miscture of gipsy and natural fibers in specific proportion of composite were produced samples which were submitted to a " parallel heat wire Test " - part 2. ISO 8894 - 2, which consists in determining of the temperature with the materal samples through a seratch with wire resistor and a thermopair with 30º grade Celsius referential interconnented, respectivey, to an eletric source and a Signal Acquisition Board which determines the thermal conductvity of the materal through the propagation of heat isothermic wawes.The studies of mixing elements of definite proportion between mixed parts, the humidity level and the porosity of the samples have been of great importance to this research. The tests showed that the best performance was obtained by the mixture of and their percentagens of 0 % a 35 of materal fiber for the time between 640 a 1280 seconds. / Mestrado / Refrigeração e Condicionamento Ambiental / Mestre em Engenharia Mecânica
19

Conforto térmico em habitações de favelas e possíveis correlações com sintomas respiratórios: o caso do Assentamento Futuro Melhor - SP / Thermic confort in slum homes and possible correlations with respiratory diseases: the case of \"Assentamento Futuro Melhor-SP\" (housing for a better future)

Isabel Utimura 18 February 2011 (has links)
O objetivo deste trabalho é verificar a influência do microclima no condicionamento do ambiente de residências representativas da favela do Assentamento Futuro Melhor do Município de São Paulo. A investigação procura isolar e caracterizar os controles climáticos cuja variação espaço-temporal seja significativa a ponto de influenciar a ocorrência e distribuição de doenças respiratórias em população de baixa renda. O estudo foi desenvolvido com base no conceito de ritmo climático e na concepção bioclimática do ambiente construído, que foram aplicados empiricamente em trabalho de campo. Foram realizados monitoramento e avaliação do conforto térmico em ambiente interno de longa permanência de oito habitações com tecnologia e padrão construtivos diferentes, usando mini-regitradores digitais de temperatura e umidade relativa do ar com frequência de amostragem de 1 hora durante o verão de 2009 ao inverno de 2010. Procurou-se isolar a influência topoclimática (orientação e posição da vertente), instalando-os num mesmo quarteirão com declividades muito baixas. Foi classificada, hora a hora, a combinação de temperatura e umidade relativa do ar resultando no índice de sensação térmica humana segundo a proposta de Olgyay (1963). A comparação do ambiente interior das habitações com o exterior foi realizada a partir de dados obtidos junto às estações meteorológicas do INMET - Mirante de Santana (SP) e do IAG-USP, e das informações da circulação secundária sobre a área de estudo obtida das cartas sinóticas da Marinha do Brasil, e imagens do satélite GOES no canal infravermelho (CPTEC/INPE). Para associar o fator conforto térmico com sintomas respiratórios recorreu-se à aplicação de questionários, buscando investigar in loco se havia uma variação da prevalência de sintomas respiratórios em função de atributos das habitações. Foram realizadas entrevistas sistemáticas com cada um dos indivíduos moradores de 150 habitações tomadas como universo amostral. Os dados dos sintomas respiratórios foram associados e agrupados segundo os tipos construtivos de habitações, o perfil socioeconômico e demográfico, além de hábitos da família que interferem no conforto térmico e/ou na saúde respiratória. Essas associações buscaram um controle das variáveis que poderiam influir na incidência de sintomas e serviram para isolar exclusivamente a influência das variáveis construtivas da habitação. Por fim, buscou-se incorporar os dados climáticos registrados às informações qualitativas levantadas junto à população moradora. Os resultados apontam para a influência do padrão construtivo nos níveis de conforto térmico, consistindo em fatores diferenciadores dos atributos microclimáticos do ambiente interior. As habitações em fechamento de madeira e cobertura de telha ondulada de fibrocimento apresentaram um isolamento menor dentre às habitações pesquisadas, sendo que a habitação em alvenaria com laje ofereceu um maior isolamento e inércia térmica em relação ao ambiente externo. As habitações em alvenaria com telha de fibrocimento apresentaram diferenças nas condições de conforto térmico em função das pequenas melhorias construtivas empregadas em cada caso. Verificou-se que nas habitações da favela ocorrem extremos de temperaturas, e que nas habitações localizadas fora do ambiente de favela, tomadas como posto de controle o mesmo não ocorreu. Sobre os efeitos meteorológicos no condicionamento do ambiente das habitações estudadas, verificou-se que os maiores resfriamentos estão associados à MPA; os maiores aquecimentos sob a ação dos sistemas tropicais TC e MTA, e as FFs criam uma situação de homogeneização nas variações das temperaturas médias horárias ao longo do dia. A análise integrada da variação horária de temperatura e umidade relativa do ar permitiu verificar que existe um ritmo sazonal nas condições de conforto térmico humano. No tocante à sensação térmica, todas as habitações da favela mostraram-se, na maior parte do tempo, fora da faixa de conforto proposta por Olgyay (1963), variando entre situações de desconforto ao calor-úmido e ao frio-úmido. Verificou-se que as habitações da favela condicionam ambientes propícios à ocorrência de sensações opostas e extremas no mesmo dia, o que não ocorre nas habitações localizadas fora do ambiente de favela. Os resultados das entrevistas indicam que nas habitações mais precárias, em madeira e alvenaria sem reboco, há maior prevalência de sintomas respiratórios do que nas habitações mais estruturadas em alvenaria com reboco. Houve associação entre a frequência e distribuição dos sintomas respiratórios e as variáveis climáticas e o índice de conforto de forma diferenciada por tipo de padrão construtivo. Os resultados corroboram a hipótese de que as habitações precárias de favelas apresentam maior impacto negativo à saúde respiratória dos moradores. As habitações da favela do Assentamento Futuro Melhor produzem o oposto daquilo que se espera de qualquer abrigo humano, pois pioram a condição do ambiente e prejudicam a saúde de seus ocupantes. / This study aims at verifying the influence of microclime on the conditioning of representative home environments of the Assentamento Futuro Melhor (\"Housing for a Better Future\") favela in the city of Sao Paulo. It is an investigation to isolate and characterize climatic controls whose space-time variation can be of significance in springing up respiratory diseases and disseminating them over a low-income population. The study was developed upon the concept of climatic rhythm as well as the bioclimatic conception of the built-on environment, applied empirically in the field work. Monitoring and evaluation of thermic comfort were carried out for long-term indoor environments in eight domiciles, each with distinct technologies and building patterns, using digital mini recorders for temperature and relative air humidity with sampling frequency of 1 hour, during the Summer of 2009 through the Winter of 2010. An attempt was made to isolate the topoclimatic influence (hogback orientation and position) by installing them in the same block, one with very little slope. The combination of temperature and relative air humidity was evaluated on an hour-to-hour basis, resulting in the human thermic sensitivity index, according to the method proposed by Olgyay (1963). The comparison between the indoor and outdoor environments of the domiciles was performed from data gathered by the meteorological stations of INMET - Mirante de Santana (SP) and of IAG-USP, along with information on secondary circulation over the area of study gathered from synoptical charts of the Brazilian Navy, as well as imagery from the GOES satellite infrared channel (CPTEC/INPE). In associating the thermic comfort factor with respiratory symptoms, question forms were handed out in loco to investigate whether a variation in the prevalence of respiratory symptoms as a function of features pertaining to the domiciles existed. Each individual dwelling in the 150 domiciles within the sample group was systematically interviewed. Data for respiratory symptoms were associated and grouped in accordance with building type, social, economic and demographic profile as well as family habits that interfer in thermic comfort and/or respiratory health. Such associations looked to control variables that could sway the incidence of symptoms, and served to exclusively isolate the influence of the domiciles\' building variables. Finally, a correlation was sought between the recorded climatic data and the qualitative information queried from the dwelling population. Results show the influence of building schemes on the level of thermic comfort, consisting in differing factors for indoor microclimatic attributes. Homes with wood enclosure, roofed with undulated, cemented fiber tiles showed the lowest isolation among the researched homes, whereas homes with mortar walls and ceiling displayed greater isolation and thermic inertia to the outer environment. Mortar homes with cemented fiber tiling showed discrepancies in the levels of thermic comfort as the result of small building improvements applied in each case. Temperature extremes were attested over the domiciles in the favela, but in domiciles outside the favela - used as \"control posts\" - such extremes could not be verified. Regarding the meteorological effects on the environment conditioning of the researched domiciles, the greatest levels in cooling were verified to be linked to MPA; the greatest levels in heating, to the action of tropical systems TC and MTA; FFs caused homogeneity in the variation of hourly average temperatures in the course of a day. Integrated analysis of hourly temperature variation and relative air humidity allowed for the conclusion that there exists a seasonal rhythm in the condition of human thermic comfort. As for thermic sensitivity, all domiciles in the favela showed for the most part as being without the comfort zone proposed by Olgyay (1963), ranging from uncomfortable conditions to humid heat and to humid cold. It was verified that the domiciles in the favela configure environments capable of offering opposite, extreme sensations within the same day, which does not occur in domiciles outside the favela environment. Interview results point to the prevalence of respiratory symptoms in the more poorly built domiciles, with wood or bricks with no plasterwork, rather than in the plasteredbrick homes. A correlation was attested among frequency and distribution of respiratory symptoms, climatic variables, and the differentiated comfort index by building pattern. The results corroborate the hypothesis that poorly built homes in favelas more negatively affect the respiratory health of their dwellers. The homes in the Assentamento Futuro Melhor favela yield the opposite of what is expected of any human shelter: worsening of environment conditions and health deterioration for their occupants.
20

Ebullition nucléée sur des surfaces ultra-polies : Influence de la topographie et du revêtement sur le phénomène de nucléation / Nucleate boiling on ultra-smooth surfaces : Influence of topography and coating on the nucleation phenomenon

Al Masri, Mostafa 07 July 2017 (has links)
Une étude expérimentale est menée afin de comprendre le phénomène de nucléation lors de l'ébullition. Cette étude est menée sur des surfaces polies miroir ou ultra-polies en aluminium, l’acétone étant le fluide de travail. L'analyse est réalisée en fonction de la topographie de la surface liée au degré de polissage et en fonction du revêtement de la surface dans le but de modifier sa mouillabilité. L’étude a mis en avant trois catégories de comportement, fonctions de l’état de surface : les surfaces nano lisses, les surfaces nano lisses avec défauts et les surfaces rugueuses. Les bonnes caractéristiques obtenues avec des échantillons nano lisses comportant des défauts aléatoirement répartis ont conduit à la réalisation d’échantillons nano lisses avec des défauts de position et de taille contrôlés. Les résultats obtenus avec ces derniers échantillons présentent les meilleures performances. Une amélioration supérieure à un facteur deux par rapport aux surfaces rugueuses est observée, ce qui représente un gain substantiel. Bien qu’il soit le fondement de la plupart des modèles théoriques, le nucléus à l’origine de la formation d’une bulle n’a jamais été observé expérimentalement car sa taille dépasse la capacité des moyens de mesure traditionnels. Dans ce mémoire, une méthode optique - basée sur la résonnance de plasmons sur des surfaces comportant un réseau de diffraction - est utilisée dans le but d’étudier ce phénomène. Les expériences mettent en évidence la capacité de cette méthode à mesurer la variation de la température pariétale de l’échantillon avant le déclenchement de l’ébullition. Les mesures de résonance plasmon montrent qu’il n’y a pas de modification de la densité du fluide au voisinage de la paroi pour des surchauffes proches du déclenchement de l’ébullition. La nucléation est trop rapide pour être mesurée. Cependant, des premiers nuclei de condensation ont été détectés par cette méthode, ce qui constitue un résultat très prometteur. / An experimental study was conducted in order to understand the phenomenon of nucleation in boiling. This study was done on smooth surface or ultra-smooth surface made of aluminum, the working fluid is acetone. The analysis was realized as a function of the topography of the sample, roughness level, and as a function of nanocoating of the surface in order to modify the wettability. The study classed the sample in three categories, depending on the surface condition: the ultra-smooth surface, the ultra-smooth surface with defect and the rough surface. The good characteristics were obtained for the ultra-smooth sample with randomly distributed defects led to the fabrication of ultra-smooth sample with controlled artificial cavity. The results obtained with these latter samples present the best performances. A two-fold improvement over rough surfaces is observed, representing a substantial gain. Although it is the foundation of most theoretical models, the nucleus at the origin of the formation of a bubble has never been observed experimentally because its size exceeds the capacity of the traditional means of measurement. In this memory, an optical method - based on the resonance of plasmons on surfaces with a diffraction grating - is used to study this phenomenon. The experiments demonstrate the ability of this method to measure the temperature variation in the wall of the sample before boiling. Plasmon resonance measurements show that there is no change in the density of the fluid near the wall for overheating close to the boiling point. The nucleation is too fast to be measured. However, first nuclei of condensation were detected by this method, which is a very promising result.

Page generated in 0.0655 seconds