• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 107
  • Tagged with
  • 107
  • 90
  • 82
  • 81
  • 26
  • 22
  • 15
  • 15
  • 15
  • 15
  • 12
  • 11
  • 10
  • 10
  • 9
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Avaliação de gases efeito estufa na cidade do Rio de Janeiro / Evaluation of green house gases in Rio de Janeiro city

Cleyton Martins da Silva 14 February 2012 (has links)
O presente trabalho teve como objetivo a validação de uma metodologia de amostragem para GEE Gases do Efeito Estufa, com a utilização de seringas e análise por cromatografia de fase gasosa com múltiplos detectores. O trabalho se dividiu em duas etapas. A primeira etapa consistiu em um teste de estabilidade avaliando o meio de amostragem proposto, a seringa, e comparando-o a dois meios de amostragem convencionais canister e bolsa de teflon -, utilizando uma amostra padrão de GEE. A segunda etapa foi a aplicação desta nova metodologia de amostragem na cidade do Rio de Janeiro, buscando a avaliação da concentração dos GEE em diferentes bairros da cidade e a correlação destas com dados meteorológicos e características da localização dos pontos amostrados. Nestas amostragens realizadas na cidade do Rio de Janeiro obteve-se uma média de 536 ppmv, 2,04 ppmv e 274 ppbv, para o CO2, CH4 e N2O, respectivamente, que foram os GEE analisados. Foi possível neste trabalho verificar o grau de correlação dos GEE estudados com variáveis meteorológicas, bem como com outros poluentes já legislados e participantes de monitoramento contínuo. As conclusões alcançadas foram que a nova metodologia proposta para amostragem de GEE é viável devido ao seu bom desempenho no teste de estabilidade, ao baixo custo do material empregado e à praticidade do mesmo, e que as concentrações dos GEE avaliados na cidade do Rio de Janeiro encontram-se superiores às concentrações indicadas como médias globais para os mesmos. Apontando desta forma, a necessidade de um monitoramento contínuo destes de forma a contribuir para a tomada de ações de mitigação dos GEE / The purpose of this study is to validate a sampling methodology for GHG Greenhouse Gases, with the use of syringes and analyzed by gas chromatography with multiple detectors. The work was divided into two steps. The first one consisted of a stability test evaluating the proposed use of sampling, the syringe, and comparing it to two conventional sampling media - canister and teflons bag - using a standard sample of GHG. The second step was the application of this new sampling methodology in the city of Rio de Janeiro, seeking the GHG concentrations assessment in different districts of the city and the correlation of these data and meteorological characteristics of the location of sampling sites. In these samples collected in the city of Rio de Janeiro resulted in an average of 536 ppmv, 2.04 ppmv and 274 ppbv, for CO2, CH4 and N2O, respectively, which were the GHG analyzed. It was possible, in this paper, to verify the degree of correlation into the studied GHG and the meteorological variables, as well into others pollutants that are already legislated and participates of a continuous monitoring plan. The conclusions reached were that the proposed new methodology for GHG sampling is viable due to its good performance in stability, low cost of the material used and the practicality of it, and that the concentrations of greenhouse gases measured in the city of Rio de Janeiro are higher than the global average concentrations of them. Pointing, this way, the need for continuous monitoring of these, that should contribute to the actions of GHG mitigation
22

Desenvolvimento de metodologia para avaliação de hidrocarbonetos policíclicos aromáticos e derivados em emissões de motores usando diesel/biodiesel / Development of methodology for evaluation of polycyclic aromatic hydrocarbons and derivatives in emissions from engines using diesel / biodiesel

Carina Santos Casal 26 March 2012 (has links)
Os hidrocarbonetos policíclicos aromáticos (HPA) são amplamente estudados na área de meio ambiente, em diversas matrizes ambientais como ar, água, solo e sedimento, devido a sua toxicidade, potencial mutagênico e carcinogênico. Por conta disto, as agências ambientais de países desenvolvidos listaram dezesseis HPA como sendo poluentes prioritários. As legislações a nível mundial não estipulam limites para estes compostos para ar ambiente, somente para emissões de fontes fixas e móveis e ambientes ocupacionais, mas existem diversos estudos, mais especificamente para os 16 prioritários HPA e muito pouco para os homólogos alquilados. Os HPA alquilados são mais abundantes, persistentes e frequentemente mais tóxicos que os não alquilados e a toxicidade aumenta com o número de substituições alquil sobre os núcleos aromáticos. As legislações ambientais em todo o mundo não realizam o controle em nenhuma matriz ambiental para os HPA alquilados. Neste trabalho foi desenvolvido um método para análise dos HPA e seus homólogos alquilados, utilizando cromatografia de fase gasosa acoplado a um detector de espectrometria de massa e com um sistema de injeção para grande volume, associado à vaporização com temperatura programada, que permitiu um nível de detecção na faixa de 0,70 até 103,6 ng mL-1, sendo possível analisar as amostras de material particulado oriundas de emissões veiculares. As amostras foram coletadas de acordo com a Norma ABNT NBR14489, em um dinamômetro de bancada para motor do ciclo diesel (Ciclo de 13 pontos). Os resultados encontrados foram na faixa de 0,5 ng mL-1 até 96,9 ng mL-1 Os resultados indicaram que motores a diesel/ biodiesel têm uma contribuição muito grande na formação destes HPA e homólogos alquilados
23

Análise direta de sólidos por espectrometria de absorção atômica de alta resolução com fonte contínua e investigação de compostos organometálicos por análise direta em tempo real com espectrometria de massa

Borges, Daniel Lázaro Gallindo January 2009 (has links)
Tese (doutorado) - Universidade Federal de Santa Catarina, Centro de Ciências Físicas e Matemáticas. Programa de Pós-Graduação em Química. / Made available in DSpace on 2012-10-24T13:06:27Z (GMT). No. of bitstreams: 1 263053.pdf: 1866994 bytes, checksum: 227ea1d23cea080f95f430fdff6c1260 (MD5) / O presente trabalho, em sua primeira parte, descreve o desenvolvimento de métodos analíticos para a determinação de elementos traço e consituintes minoritários por espectrometria de absorção atômica de alta resolução com fonte contínua (HR-CS AAS), com análise direta de amostras sólidas (SS). Inicialmente, são mostrado resultados para a determinação de Pb em amostras biológicas. O procedimento utilizou Ru como modificador permanente e calibração utilizando padrões aquosos, com bons resultados para a análise de sete materiais de referência certificados. A correção de fundo por mínimos quadrados (LSBC) demonstrou que o espectro molecular observado em temperaturas elevadas de atomização correspondia a monóxido de fósforo (PO). A determinação de Ag, por sua vez, foi conduzida em amostras geológicas, sem uso de modificadores. Para amostras de solos e sedimentos, calibração com padrões aquosos permitiu a obtenção de resultados concordantes com valores informados, ao passo que a análise de rochas e minérios requereu calibração com material de referência sólido. A LSBC foi conduzida para demonstrar a correção para fundo estruturado decorrente da molécula de SH. Em uma terceira aplicação, Cr e Fe foram simultaneamente determinados em amostras de alimentos por SS-HR-CS AAS, através da linha principal de Cr em 357,869 nm e de uma linha secundária de Fe em 358,119 nm. Bons resultados foram obtidos para a análise de 4 materiais de referência certificados, comprovando a boa exatidão para a análise simultânea. Por fim, nanotubos de carbono de parede simples e de paredes múltiplas foram analisados para a determinação de Ag, Co, Cr, Ni e Pb por SS-HR-CS AAS. A determinação de Ag e Pb procedeu de maneira análoga aos procedimentos anteriormente descritos, embora sem uso de modificador, ao passo que Co, Cr e Ni foram determinados de maneira simultânea, na região espectral em torno da linha secundária de Cr em 360,538 nm. Em função das concentrações elevadas, as asas das linhas foram utilizadas para propósitos analíticos, resultando em redução de sensibilidade e aumento de linearidade das curvas de calibração. Boa concordância foi obtida na comparação com resultados obtidos por procedimento de extração e análise por espectrometria de massa com plasma indutivamente acoplado (ICP-MS). Em todos os procedimentos, limites de detecção variando entre 0,002 µg g-1 (Ag) e 1,5 mg g-1 (Co em linha secundária) foram obtidos, sendo adequados aos métodos propostos. A segunda parte do trabalho envolveu a investigação de compostos organometálicos utilizando a espectrometria de massa (MS) com análise direta em tempo real (DART). Diversos compostos organometálicos de As, Fe, Hg, Pb, Se e Sn foram analisados por MS quanto aos sinais correspondentes obtidos por ionização pela fonte DART. Padrões de fragmentação colisional induzida foram também avaliados. Dois procedimentos distintos de amostragem, com algodão exposto ao plasma da fonte DART e com análise do headspace dos compostos puros e/ou dissolvidos em tolueno, foram utilizados. A amostragem por headspace permitiu obter sinais temporalmente estáveis, possibilitando avaliar os efeitos dos parâmetros operacionais da fonte DART sobre os sinais obtidos. Constatou-se que a ativação de dois dos eletrodos que compõem a fonte DART, com a função eliminar íons do fluxo de gás, causou diminuição na intensidade dos sinais para a maioria dos compostos, o que pode ser indício da participação de espécies iônicas do plasma na ionização dos diferentes compostos. Algumas tentativas de aplicação dos procedimentos descritos à detecção de organometálicos em amostras "reais" foram conduzidas, embora apenas sinais de baixa intensidade em razões m/z elevadas tenham sido detectados. The present work describes, in its first section, the development of analytical methods aiming to determine trace elements and minor constituents using high-resolution continuum source atomic absorption spectrometry (HR-CS AAS) and direct solid sampling (SS). Initially, results are shown for the determination of Pb in biological samples. The procedure employed Ru as permanent modifier and calibration against aqueous standards, resulting in good agreement between determined and certified values for the analysis of seven certified reference materials. Least-squares background correction is shown to demonstrate that the molecular spectrum observed at elevated atomization temperatures is due to the presence of the phosphorus monoxide (PO) molecule. The determination of Ag has also been carried out, without using chemical modifiers, in geological samples. For soil and sediment analysis, calibration against aqueous standards allowed good agreement between informed and determined values, whereas rock and ore analysis required calibration against a solid reference material. LSBC was employed in order to demonstrate that the molecular spectrum detected was due to the SH molecule. In a third independent procedure, Cr and Fe have been simultaneously determined in food samples using the main Cr line at 357.869 nm and a secondary Fe line at 358.119 nm. Good results were obtained for the analysis of four certified reference materials, attesting the good accuracy of the simultaneous determination procedure. Finally, single and multi-walled carbon nanotubes have been analyzed, aiming to determine Ag, Co, Cr, Ni and Pb by SS-HR-CS AAS. The determination of Ag and Pb was carried out similarly to the procedures previously described, except for the absence of chemical modifiers for Pb. Cobalt, Cr and Ni were determined simultaneously, in the spectral region in the vicinity of the secondary Cr line at 360.538 nm. Due to the high concentration found in the carbon nanotubes samples, line wings have been used for analytical purposes, resulting in reduced sensitivity and increased linear working range. Good agreement with the concentration of Co, Ni and Pb was obtained in comparison to the results determined by a microwave-assisted extraction procedure and inductively coupled plasma mass spectrometry (ICP-MS). All the developed methodologies resulted in detection limits ranging between 0.002 µg g-1 (Ag) and 1.5 mg g-1 (secondary Co line), which have proved to be adequate to the proposed analytical procedures. The second part of the work describes the investigation that has been carried out using organometallic compounds and mass spectrometry (MS) with direct analysis in real time (DART). Several organometallic compounds of As, Fe, Hg, Pb, Se and Sn have been used in the investigation, aiming to identify their corresponding mass spectra obtained using DART as the ion source. Induced fragmentation patterns have also been evaluated. Two distinct sampling procedures, using cotton exposed to the DART plasma or headspace sampling of pure or toluene-solutions of the organometallic compounds, have been employed. Headspace sampling allowed temporally stable signals to be obtained, allowing to evaluate the effect of DART operating parameters on the intensity and pattern of the signals obtained. Results have shown that the activation of two of the electrodes that integrate the DART source, which are supposed to remove ions from the gas stream, resulted in the reduction in signal intensity for most of the compounds investigated, which seems to indicate the ionic species of the plasma participate in the ionization process of the organometallic compounds. A few attempts to identify organometallic signals in 'real' samples have been carried out, although only low-intensity signals at high m/z ratios could be observed.
24

Emprego da geração fotoquímica de vapor para análise de especiação e determinação de elementos-traço por espectrmetria atômica e de massa

Quadros, Daiane Paula Cunha de January 2015 (has links)
Tese (doutorado) - Universidade Federal de Santa Catarina, Centro de Ciências Físicas e Matemáticas, Programa de Pós-Graduação em Química, Florianópolis, 2015. / Made available in DSpace on 2015-09-08T04:07:06Z (GMT). No. of bitstreams: 1 334077.pdf: 4801027 bytes, checksum: 4ea066b8baf03b0ab1abf5c6b6a6df70 (MD5) Previous issue date: 2015 / Este trabalho abrange duas técnicas distintas para a determinação de elementos-traço com auxílio da geração fotoquímica de vapor: uma utilizando uma lâmpada de ultravioleta (UV) para a geração da radiação UV com detecção por espectrometria de massa com plasma indutivamente acoplado (ICP-MS) e outra utilizando uma interface micro-ondas/ultravioleta (MW/UV) para a geração da radiação UV e acoplamento com cromatografia líquida de alta eficiência (HPLC) e espectrometria de fluorescência atômica (AFS) para fins de especiação de Hg. Para a análise por ICP-MS, foi desenvolvido um reator fotoquímico aplicável à determinação de Co, Ni e Te em bebidas alcoólicas e determinação de Fe, Sc, Hg e V em amostras de água de mar. Espécies voláteis de Co, Ni, Te, Fe, Sc, Hg e V foram geradas a partir da combinação entre as respectivas soluções padrão e uma mistura dos ácidos fórmico e acético após exposição a uma fonte de UV. Os limites de quantificação de 0,5, 0,1 e 0,4 ng mL-1 para Co, Ni e Te, respectivamente, foram obtidos para a análise de bebidas alcoólicas, os quais correspondem a ganhos de 9, 35 e 3 vezes em relação à análise com nebulização pneumática. Para Hg e V, os limites de quantificação foram de 1,5 e 5,0 ng mL-1, respectivamente, ao passo que Fe e Sc não puderam ser quantificados nas amostras de água do mar, embora a detecção tenha sido realizada com sucesso. Em um segundo projeto, a técnica de geração fotoquímica de vapor por meio de uma interface MW/UV foi acoplada à cromatografia líquida de alta eficiência e à espectrometria de fluorescência atômica (HPLC-AFS) para a quantificação de mercúrio inorgânico, metilmercúrio e etilmercúrio. Durante o processo de desenvolvimento da metodologia foram utilizados os ácidos fórmico, acético, malônico e cítrico para estudos, e o emprego de ácido fórmico como fase móvel mostrou-se mais eficiente para a foto-decomposição de compostos organometálicos de mercúrio e para a redução de Hg2+ a Hg0 sob as condições de MW/UV. Diversos parâmetros operacionais foram avaliados, incluindo o tipo de ácido orgânico e sua concentração, potência de MW, composição da fase móvel de HPLC e ação catalítica de nanopartículas de TiO2. Sob as condições otimizadas, os limites de detecção foram de 0,15, 0,15 e 0,35 ng mL-1 para o mercúrio inorgânico, metilmercúrio e etilmercúrio, respectivamente. O método desenvolvido foi aplicado à análise de três materiais de referência certificados, todos de procedência biológica. A interface online da cromatografia líquida com a fluorescência atômica e a geração fotoquímica de vapor para a determinação de mercúrio é simples, contribui para redução do impacto ambiental associado à análise e representa uma alternativa atraente para o sistema de geração química de vapor baseada no uso de tetraidroborato.<br> / Abstract : This work consists of two distinct approaches for the determination of trace elements by spectrometric techniques, following photochemical vapor generation: in the first approach, an ultraviolet lamp (UV) was used for the generation of volatile species prior to determination by inductively coupled plasma mass spectrometry (ICP-MS); the second approach involved a microwave/ultraviolet (MW/UV) interface for the generation of UV radiation and coupling with high performance liquid chromatography (HPLC) and atomic fluorescence spectrometry (AFS) to carry out speciation analysis. Firstly, a photochemical reactor was built and applied to the development of a new and sensitive method for the determination of Co, Ni and Te in alcoholic beverages and for the identification of Fe, Sc, Hg and V in seawater samples. For these applications, photochemical vapor generation was coupled to an ICP-MS instrument. The volatile species of Co, Ni, Te, Fe, Sc, Hg and V were generated from the combination of a mixture of formic and acetic acid after exposure to a UV source. Limits of quantification of 0.5, 0.1 and 0.4 ng mL-1 for Co, Ni and Te, respectively, were obtained for the analysis of alcoholic beverages, which correspond to 9 (Co), 35 (Ni), and 3 (Te) times improvements over those obtained with conventional pneumatic nebulization. The same setup was adopted for the detection of Hg and V, resulting in quantification limits of 1.5 and 5.0 ng mL-1, respectively. Iron and Sc could not be quantified in seawater samples, although both elements could be effectively detected. On a second project, the hyphenation of photochemical vapor generation with HPLC-AFS was described for the quantification of inorganic mercury, methylmercury and ethylmercury in biological tissues. Formic acid, which was chosen as the mobile phase, was used for the photodecomposition of organomercury compounds and for the reduction of Hg2 + to Hg0 vapor under MW/UV irradiation. The influence of several operating parameters on the response and chromatographic separation efficiency of the species were evaluated, including the type of organic acid and its concentration, MW power, composition of the HPLC mobile phase and catalytic action of TiO2 nanoparticles. Under the optimized conditions, the limits of detection were 0.15, 0.15 and 0.35 ng mL- 1 for inorganic mercury, methylmercury and ethylmercury, respectively. The main analytical figures of merit were determined and the method was applied to the analysis of three certified reference materials. The online interfacing of liquid chromatography with photochemical-vapor generation atomic fluorescence spectrometry for mercury determination was proven relatively simple, environmentally friendly and represents an attractive alternative to the use of chemical vapor generation methods that adopt tetrahydroborate as a reagent.
25

Aplicação dos processos de coagulação/floculação e adsorção em carvão ativo no tratamento primário dos efluentes de indústrias de defensivos agrícolas. / Aplicação dos processos de coagulação/floculação e adsorção em carvão ativo no tratamento primário dos efluentes de indústrias de defensivos agrícolas. / Use of coagulation/flocculation and activated carbon adsortion processes in the primary wastewater treatment from pesticides industries. / Use of coagulation/flocculation and activated carbon adsortion processes in the primary wastewater treatment from pesticides industries.

Gabriela de Carvalho Breia 15 December 2006 (has links)
No presente trabalho foi estudado o tratamento do efluente líquido de uma indústria de defensivos agrícolas, que se caracteriza por apresentar alta DQO (Demanda Química de Oxigênio) e alta toxicidade. O principal objetivo deste trabalho foi investigar o processo de coagulação/floculação associado ao processo de adsorção em carvão ativo na remoção de DQO e na redução da toxicidade do efluente, para adequá-lo ao tratamento posterior por lodos ativados. Foram realizados testes para analisar a eficiência desse processo e obteve-se uma excelente redução na DQO e uma boa redução da toxicidade. A remoção média de DQO ficou entre 73,4 e 93,5% e todas as correntes encontravam-se dentro dos limites estabelecidos pela DZ-205, legislação estadual da FEEMA (Fundação Estadual de Engenharia do Meio Ambiente) para envio à unidade de tratamento biológico. Obteve-se também boa redução da toxicidade, o que indica que os efluentes analisados podem ser enviados para o tratamento biológico. Essa metodologia também permitiu a otimização do processo de pré-tratamento dos efluentes em diversos aspectos: redução do consumo de carvão ativo, redução do tempo de operação e redução de 19,7% nos custos operacionais. / In the present work the wastewater treatment from a pesticides industry was investigated, the wastewater has the following characteristics: high COD (Chemical Oxygen Demand) and sometimes high toxicity. The main objective of this study was to investigate the coagulation/floculation process associated with the activated carbon adsorption process to remove COD and to reduce toxicity from the wastewater, leading it adequate for a latter treatment with activated sludge. The results showed that the process led to an excellent reduction of COD and an appreciable reduction of the toxicity. The COD removal was comprised between 73.4 and 93.5% and the treated effluents fulfilled the requirements established by DZ-205 from FEEMA (Fundação Estadual de Engenharia do Meio Ambiente). Toxicity was appreciably removed, indicating that the treated effluent can be sent to a biological treatment process. It was possible to improve the wastewater pre-treatment process in some aspects: reduction of the activated carbon consumption, reduction of the operational process duration and reduction of 19.7% on the operational costs.
26

Produção de biodiesel por transesterificação enzimática de óleo de soja / Biodiesel production by enzymatic transesterification of soybean

Otávio Luiz Bernardes 30 May 2008 (has links)
Neste trabalho, foi investigada a alcoólise do óleo de soja com álcool utilizando uma lipase comercial imobilizada (Lipozyme RM IM). As reações foram realizadas em um reator batelada fechado acoplado a um condensador e com constante agitação. Foi determinada a influência do álcool (metanol ou etanol), quantidade de enzima, razão molar álcool/óleo de soja, solvente e temperatura na produção de biodiesel. A etanólise do óleo de soja por sucessivas adições de álcool foi investigada. As melhores condições foram obtidas em um sistema livre de solvente com razão molar etanol/óleo igual a 3,0, temperatura de 50C e concentração de enzima de 7% em massa. A etanólise em batelada com 3 adições sucessivas foi a mais eficiente para a produção de biodiesel. Nessas condições, o rendimento em ésteres etílicos foi cerca de 55% após 2h de reação. A alcoólise de óleo de soja com metanol e etanol também foi estudada com KOH. O efeito do álcool (metanol ou etanol), concentração do catalisador e razão molar entre álcool e óleo de soja foi determinada. O maior rendimento (92%) na alcoólise do óleo de soja com KOH foi obtido com metanol / In this work, enzymatic alcoholysis of soybean oil with alcohol was investigated using a commercial immobilized lipase (Lipozyme RM IM). Reactions were carried out in a closed batch reactor with constant stirring and coupled with condenser. The influence of alcohol (methanol or ethanol), enzyme amount, molar ratio of alcohol to soybean oil, solvent (n-hexane) and temperature on biodiesel production was determined. The ethanolysis of soybean oil by successive additions of ethanol was also investigated. The best conditions were obtained in a solvent-free system with ethanol/oil molar ratio of 3.0, temperature of 50oC and enzyme concentration of 7.0% (w/w). Three-step batch ethanolysis was most effective for the production of biodiesel. In these conditions, ethyl esters yield was about 55% after 2 hours of reaction. Alcoholysis of soybean oil with methanol and ethanol were also investigated using KOH. The effects of alcohol (methanol or ethanol), catalyst concentration and molar ratio of alcohol to soybean oil was determined. The highest yield (92%) in the alcoholysis of soybean oil using KOH was obtained with methanol
27

Degradação de corante por partículas de ferro zero suportadas em sílica / Degradation of dye by zero iron supported on silica

Natália da Silva Freitas 10 February 2014 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / A água é um bem essencial a todos os seres vivos. Porém, o homem não tem dado o valor e atenção necessários para a preservação dessa riqueza. Por mais que o ser humano não faça a água desaparecer do planeta, ele tem contribuído e muito para o decréscimo de sua qualidade. Dentre as várias atividades antropogênicas, que tem contribuído para a poluição das águas, destaca-se a atividade industrial. A indústria têxtil, por exemplo, libera enormes volumes de dejetos, destacando-se os corantes, além deles prejudicarem a ocorrência de fotossíntese, apresentam elevada toxicidade ao meio marinho. Com isso, este trabalho visa estudar a degradação do corante Alaranjado de Metila via catálise heterogênea. Neste estudo, foram realizadas a preparação e a caracterização de partículas metálicas estabilizadas em sílica, sendo essas partículas com diferentes teores de ferro (50 %wt, 25 %wt e 5 %wt) aderido ao suporte. Após o preparo dos catalisadores realizou-se o estudo de sua eficiência frente a diferentes parâmetros como: quantidade de catalisador, temperatura e pH. Por meio dos testes realizados foi possível observar que a quantidade do catalisador influência a reação de redução do corante Alaranjado de Metila. Porém, quando se atinge o ponto de saturação, mesmo que se adicione mais catalisador não é possível aumentar a degradação. Através da variação da temperatura, observou-se que quanto maior a temperatura maior a degradação do corante. Isso pode ser explicado devido o aumento do número de colisões entre os sítios ativos do catalisador e as moléculas do corante. E por meio da variação de pH, concluiu-se que pHs ácidos permitem que a reação de redução do corante ocorra mais rápido e pHs elevados tornam a reação de degradação do corante mais lenta, porém ainda assim ocorrem de forma satisfatória. O catalisador pôde ser reutilizado por até 3 vezes, sem nenhum tratamento prévio. Os catalisadores a 50 %wt, assim como, a 25 %wt foram capazes de degradar o corante de forma eficiente, porém o catalisador a 5 %wt não se mostrou ser eficaz. Foram realizados testes sob radiação microondas e a reação de redução ocorreu de forma muito eficaz, apresentando 100% de degradação em apenas 2 minutos. Além disso, realizou-se o estudo cinético, onde segundo dados experimentais, as reações foram classificadas como sendo de primeira ordem / Water is essential to all living beings. However, man has not given the necessary value and attention to preserve this wealth. Although humans do not make the water disappear from the planet, he has contributed much to the decline of its quality. Among various anthropogenic activities that, has contributed to water pollution, the industrial activity is one of the most prejudicials. The textile industry, for example, releases huge volumes of waste mainly dyes, which compromises the occurrence of photosynthesis and have high toxicity to the marine environment. Thus, this work aims to study the degradation of Methyl Orange via heterogeneous catalysis. In this study, preparation and characterization of metal particles stabilized silica were made, and these particles with different iron levels (50 %wt, 25 %wt and 5 %wt) attached to the support. The effect of various parameters such as initial pH, temperature and amount of catalyst on decolourization process were studied. Through testing it was observed that the amount of the catalyst influences the reduction reaction of the dye Methyl Orange. But when it reaches the saturation point, even if you add more catalyst is not possible to increase the degradation. By varying the temperature, it was observed that the higher the temperature the greater the degradation of the dye. This can be explained by the increased number of collisions between the active sites of the catalyst and the dye molecules. And by varying pH, it was found that acidic pHs allow the reduction reaction of the dye occurs faster and higher pHs make the degradation reaction of the dye slower , but still occur satisfactorily. The catalyst can be reused up to 3 times, without any prior treatment. Catalysts 50 %wt, and 25 %wt were able to degrade efficiently the dye, but the catalyst 5 %wt not proved to be effective. Tests under microwave radiation were performed and the reduction reaction occurred very effectively, with 100% degradation in just 2 minutes. Furthermore, we carried out the kinetic study, where according to experimental data, the reactions were classified as being of first order
28

Avaliação de carbonilas na atmosfera interior e exterior de salas de aula de escolas públicas / Evaluation of carbonyls indoor and outdoor the atmosphere of public classrooms

Márcio de Mello Gomes 24 March 2014 (has links)
Compostos carbonílicos representam uma das principais classes de poluentes atmosféricos e são frequentemente reportados em estudos de poluição atmosférica de interiores. São emitidos para a atmosfera a partir de uma variedade de fontes naturais e antropogênicas. Em projeto empreendido em 2011 pela Secretaria de Estado de Educação do Estado do Rio de Janeiro,foi implementada a climatização em todas as salas de aula de todas as escolas da rede pública estadual. A escala de exposição de ocupantes à climatização, em salas de aula, não apresenta precedentes em nosso estado e representa uma tendência de todo o país. Como é um projeto recente, não há dados a respeito da qualidade do ar interior nesses ambientes e, portanto, das consequências na saúde dos ocupantes. Os procedimentos foram baseados na metodologia TO-11A da U.S.EPA. A técnica de amostragem foi por via seca com reação química, empregando-se cartuchos de sílica revestidos de octadecil (SiO2-C18) impregnados com 2,4-dinitrofenilhidrazina. As carbonilas foram analisados através de Cromatografia Líquida de Alta Eficiência com detecção por UV. Foram encontradas concentrações de formaldeído na faixa de 3,59 a 26,62 &#956;g m-3 (interior) e 0,74 a 23,47 &#956;g m-3 (exterior), acetaldeído na faixa de 0,19 a 259,47 &#956;g m-3 (interior) e 1,19 a 127,51 &#956;g m-3 (exterior), acetona+acroleína na faixa de 0,00 a 48,45 &#956;g m-3 (interior) e 0,00 a 37,00 &#956;g m-3 (exterior). Os valores encontrados geralmente não ultrapassaram os limites determinados por organismos internacionais / Carbonyl compounds represent one of most important classes of atmospheric pollutants and are frequently reported in indoor atmospheric pollution studies. Are emitted for atmosphere from a wide variety of natural and anthropogenic sources. In a project undertaken in 2011 by State Department of Education of Rio de Janeiro, all classrooms were acclimatized in all public schools statewide. The exposure scale of occupants to closed acclimatized classrooms has no precedent in our state and represents a trend throughout the country. As it is a recent project, there are no data regarding the indoor air quality in these environments and, therefore, the consequences on the health of occupants. The procedures were based on the TO-11A U.S.EPA methodology. The sampling technique is dry chemical reaction, using silica coated with octadecyl cartridges impregnated with 2,4-dinitrophenylhydrazine.Carbonyls were analyzed by High Performance Liquid Chromatography wit UV detection. Formaldehyde concentrations were found in range of 3.59 to 26.62 &#956;g m-3 (indoor) and 0.74 to 23.47 &#956;g m-3 (outdoor), acetaldehyde in range of 0.19 to 259.47 &#956;g m-3 (indoor) and 1.19 to 127.51 &#956;g m-3 (outdoor), acetone+ acrolein range of 0.00 to 48.45 &#956;g m-3 (indoor) and 0.00 to 37.00 &#956;g m-3 (outdoor). The values found generally did not exceed the limits set by international organizations
29

Avaliação de gases efeito estufa na cidade do Rio de Janeiro / Evaluation of green house gases in Rio de Janeiro city

Cleyton Martins da Silva 14 February 2012 (has links)
O presente trabalho teve como objetivo a validação de uma metodologia de amostragem para GEE Gases do Efeito Estufa, com a utilização de seringas e análise por cromatografia de fase gasosa com múltiplos detectores. O trabalho se dividiu em duas etapas. A primeira etapa consistiu em um teste de estabilidade avaliando o meio de amostragem proposto, a seringa, e comparando-o a dois meios de amostragem convencionais canister e bolsa de teflon -, utilizando uma amostra padrão de GEE. A segunda etapa foi a aplicação desta nova metodologia de amostragem na cidade do Rio de Janeiro, buscando a avaliação da concentração dos GEE em diferentes bairros da cidade e a correlação destas com dados meteorológicos e características da localização dos pontos amostrados. Nestas amostragens realizadas na cidade do Rio de Janeiro obteve-se uma média de 536 ppmv, 2,04 ppmv e 274 ppbv, para o CO2, CH4 e N2O, respectivamente, que foram os GEE analisados. Foi possível neste trabalho verificar o grau de correlação dos GEE estudados com variáveis meteorológicas, bem como com outros poluentes já legislados e participantes de monitoramento contínuo. As conclusões alcançadas foram que a nova metodologia proposta para amostragem de GEE é viável devido ao seu bom desempenho no teste de estabilidade, ao baixo custo do material empregado e à praticidade do mesmo, e que as concentrações dos GEE avaliados na cidade do Rio de Janeiro encontram-se superiores às concentrações indicadas como médias globais para os mesmos. Apontando desta forma, a necessidade de um monitoramento contínuo destes de forma a contribuir para a tomada de ações de mitigação dos GEE / The purpose of this study is to validate a sampling methodology for GHG Greenhouse Gases, with the use of syringes and analyzed by gas chromatography with multiple detectors. The work was divided into two steps. The first one consisted of a stability test evaluating the proposed use of sampling, the syringe, and comparing it to two conventional sampling media - canister and teflons bag - using a standard sample of GHG. The second step was the application of this new sampling methodology in the city of Rio de Janeiro, seeking the GHG concentrations assessment in different districts of the city and the correlation of these data and meteorological characteristics of the location of sampling sites. In these samples collected in the city of Rio de Janeiro resulted in an average of 536 ppmv, 2.04 ppmv and 274 ppbv, for CO2, CH4 and N2O, respectively, which were the GHG analyzed. It was possible, in this paper, to verify the degree of correlation into the studied GHG and the meteorological variables, as well into others pollutants that are already legislated and participates of a continuous monitoring plan. The conclusions reached were that the proposed new methodology for GHG sampling is viable due to its good performance in stability, low cost of the material used and the practicality of it, and that the concentrations of greenhouse gases measured in the city of Rio de Janeiro are higher than the global average concentrations of them. Pointing, this way, the need for continuous monitoring of these, that should contribute to the actions of GHG mitigation
30

Desenvolvimento de metodologia para avaliação de hidrocarbonetos policíclicos aromáticos e derivados em emissões de motores usando diesel/biodiesel / Development of methodology for evaluation of polycyclic aromatic hydrocarbons and derivatives in emissions from engines using diesel / biodiesel

Carina Santos Casal 26 March 2012 (has links)
Os hidrocarbonetos policíclicos aromáticos (HPA) são amplamente estudados na área de meio ambiente, em diversas matrizes ambientais como ar, água, solo e sedimento, devido a sua toxicidade, potencial mutagênico e carcinogênico. Por conta disto, as agências ambientais de países desenvolvidos listaram dezesseis HPA como sendo poluentes prioritários. As legislações a nível mundial não estipulam limites para estes compostos para ar ambiente, somente para emissões de fontes fixas e móveis e ambientes ocupacionais, mas existem diversos estudos, mais especificamente para os 16 prioritários HPA e muito pouco para os homólogos alquilados. Os HPA alquilados são mais abundantes, persistentes e frequentemente mais tóxicos que os não alquilados e a toxicidade aumenta com o número de substituições alquil sobre os núcleos aromáticos. As legislações ambientais em todo o mundo não realizam o controle em nenhuma matriz ambiental para os HPA alquilados. Neste trabalho foi desenvolvido um método para análise dos HPA e seus homólogos alquilados, utilizando cromatografia de fase gasosa acoplado a um detector de espectrometria de massa e com um sistema de injeção para grande volume, associado à vaporização com temperatura programada, que permitiu um nível de detecção na faixa de 0,70 até 103,6 ng mL-1, sendo possível analisar as amostras de material particulado oriundas de emissões veiculares. As amostras foram coletadas de acordo com a Norma ABNT NBR14489, em um dinamômetro de bancada para motor do ciclo diesel (Ciclo de 13 pontos). Os resultados encontrados foram na faixa de 0,5 ng mL-1 até 96,9 ng mL-1 Os resultados indicaram que motores a diesel/ biodiesel têm uma contribuição muito grande na formação destes HPA e homólogos alquilados

Page generated in 0.0455 seconds