• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 167
  • 143
  • 90
  • 51
  • 30
  • 14
  • 10
  • 7
  • 5
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 570
  • 115
  • 82
  • 72
  • 72
  • 65
  • 64
  • 61
  • 61
  • 61
  • 60
  • 47
  • 47
  • 43
  • 42
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
261

Long-term periodontal status of maxillary central incisors after orthodontic traction: CBCT and clinical findings / Condição periodontal em longo prazo de incisivos centrais superiores após o tracionamento ortodôntico: TCFC e achados clínicos

Calil, Louise Resti 28 March 2018 (has links)
Purpose: The aim of this study was to evaluate the buccal and lingual alveolar bone morphology and the periodontal clinical condition of impacted permanent maxillary central incisors at least 6 months after the orthodontic traction. Methods: This split mouth transversal study evaluated a sample of 11 patients a mean of 15.41 years after the orthodontic traction of unilateral impacted maxillary central incisor. The experimental group (TR) consisted of 11 impacted central incisors. The comparison group (NTR) consisted of 11 non-impacted contralateral teeth. High-resolution CBCT exams of central incisors were performed using Accuitomo (J. Morita, Kyoto, Japan). Cross section imagens passing through the center of maxillary central incisors were used to measure buccal and lingual alveolar bone level. Presence of fenestration, root dilacerations, root coverage, and position of the root apex were also assessed in the same images. Clinical parameters included the periodontal probing depth, attachment level, gingival bleeding index, plaque index, degree of gingival recession, amount of gingival mucosa and evaluation of interproximal papilla and black triangle. Digital model analysis included an assessment of clinical crown height and width. Intergroup comparisons were performed using paired t tests, McNemar and Wilcoxon tests (p<0.05). Pearson correlation coefficient was calculated to determine the relationship between the clinical and CBCT findings. Results: TR group showed a significantly thinner buccal bone plate thickness at the middle and apical root level compared to NTR group. A decreased buccal alveolar crest level was observed in TR group in comparison to NTR group. The TR group showed a greater frequency of buccal bone dehicences and root dilacerations than antimeres. Experimental group showed more gingival recession, a decreased amount of gingival mucosa and an increased clinical attachment level at the buccal aspect than the NTR group. Moderate inverse correlation was found between buccal bone plate thickness of central incisors and attachment level and moderate positive correlation was found between buccal alveolar crest height and attachment level Conclusions: The periodontal conditions of maxillary central incisors long-term after orthodontic traction are different compared to its antimere. A decreased thickness and height of buccal alveolar bone and gingival recessions were observed in central incisors 15 years after orthodontic traction. / Introdução: o objetivo deste estudo foi avaliar a morfologia óssea alveolar vestibular e lingual e a condição clínica periodontal de incisivos centrais superiores impactados há, pelo menos, 6 meses após o tracionamento ortodôntico. Material e Métodos: Este estudo transversal de boca dividida avaliou uma amostra de 11 pacientes com média de 15,41 anos após a mecânica de tração ortodôntica de incisivo central superior retido unilateral. O grupo experimental (TR) foi composto por 11 incisivos centrais retidos. O grupo controle (NTR) foi composto por 11 incisivos contralaterais irrompidos naturalmente. Exames de TCFC de alta resolução dos incisivos centrais foram realizados utilizando o Accuitomo (J. Morita, Kyoto, Japão). As imagens transversais que passaram pelo centro dos incisivos centrais superiores foram utilizadas para medir o nível ósseo alveolar vestibular e lingual. A presença de fenestração, dilaceração, recobrimento radicular e posição do ápice radicular também foram avaliados nas mesmas imagens. Os parâmetros clínicos incluíram profundidade de sondagem periodontal, nível de inserção clínico, índice de sangramento gengival, índice de placa, grau de recessão gengival, quantidade de mucosa queratinizada e avaliação da presença de triângulo negro na papila interproximal. A análise de modelo digital consistiu da avaliação da altura e largura da coroa clínica. As comparações intergrupos foram realizadas utilizando os testes de t pareado, McNemar e Wilcoxon (p<0,05). O coeficiente de correlação de Pearson foi calculado para determinar a relação entre os achados clínicos e TCFC. Resultados: o grupo TR apresentou uma espessura da tábua óssea vestibular significantemente mais fina em nível médio e apical da raiz, em comparação ao grupo NTR. Observou-se uma diminuição do nível da crista alveolar vestibular no grupo TR em comparação ao grupo NTR. O grupo TR mostrou uma maior frequência de deiscência óssea vestibular e dilaceração radicular quando comparado aos contralaterais. O grupo experimental revelou maior recessão gengival, diminuição da quantidade de mucosa gengival e maior do nível de inserção clínico na face vestibular, em comparação ao grupo NTR. Verificou-se uma correlação inversa entre a espessura da tábua óssea vestibular dos incisivos centrais e o nível de inserção clínico e uma positiva correlação entre a altura da crista alveolar vestibular e o nível de inserção, ambas moderadas. Conclusões: As condições periodontais dos incisivos centrais superiores em longo prazo após o tracionamento ortodôntico são diferentes em comparação aos contralaterais. Uma menor espessura e altura óssea alveolar vestibular, bem como presença de recessões gengivais foram observadas nos incisivos centrais 15 anos após o tracionamento ortodôntico.
262

Estudo cefalométrico comparativo entre o recurso da Teoria de Força das Dez Horas e o uso do aparelho extrabucal / Cephalometric effects produced by Ten Hour Force Theory application and cervical headgear, both followed by the fixed appliance therapy for Class II treatment

Marise de Castro Cabrera 07 July 2008 (has links)
Este estudo objetivou comparar os efeitos cefalométricos promovidos por dois protocolos diferentes com a finalidade de corrigir a má oclusão de Classe II: Aparelho Extrabucal associado ao aparelho fixo (grupo AEB) e o recurso da Teoria de Força das Dez Horas, que consiste no uso de aparelho ortodôntico fixo, 8 horas diárias de uso de aparelho extrabucal e 16 horas de uso de elásticos de Classe II, sendo 8 horas com apoio no primeiro molar inferior e 8 horas com apoio no segundo molar inferior (grupo T10). O grupo T10 consistiu de 31 pacientes, com idade média inicial de 14,90 anos, idade média final de 17,25 anos e tempo médio de tratamento de 2,35 anos. O grupo AEB consistiu de 28 pacientes com idade média inicial de 13,98 anos, idade média final de 16,46 anos e tempo médio de tratamento de 2,47 anos. Foram avaliadas as telerradiografias em norma lateral de todos os pacientes, nas fases pré e pós-tratamento ortodôntico. Para comparação entre os grupos, foi utilizado o teste t independente. Os resultados demonstraram que os molares superiores sofreram maior inclinação para distal e maior extrusão no grupo AEB. Os molares inferiores apresentaram uma discreta extrusão e mesialização em ambos os grupos, porém sem diferença estatisticamente significante, mostrando que os molares inferiores não sofreram maior mesialização devido ao uso dos elásticos no grupo T10. A relação molar de Classe II foi melhor corrigida no grupo da T10, provavelmente pela falta de cooperação do paciente no uso do aparelho extrabucal. Concluiu-se que a Teoria das Dez Horas é válida porque o uso de elásticos de Classe II não influenciou a posição dos dentes inferiores. / This study aimed to compare the cephalometric effects promoted by two different protocols to correct the Class II malocclusion: Extraoral Appliance associated to fixed appliances and the Ten-Hour Force Theory, that consists in the use of fixed appliances, 8 hours a day using extraoral appliance and 16 hours a day using Class II elastics, 8 hours in the first mandibular molar and 8 hours in the second mandibular molar. The T10 group comprised 31 patients with a mean initial age of 14.90 years, final age of 17.25 years and mean treatment time of 2.35 years. The Extraoral group comprised 28 patients with a mean initial age of 13.98 years, final age of 16.46 years and a mean treatment time of 2.47 years. It was evaluated the lateral cephalograms of all patients in pretreatment and posttreatment stages. Intergroup comparison of treatment changes was performed by t tests. Maxillary molars presented greater distal tipping and extrusion in Extraoral group, showing that mandibular molars did not present greater mesial movement caused by use of elastics in T10 group. Class II molar relationship was better corrected in T10 group than in Extraoral group, certainly due to the lack of patient compliance in the use of extraoral appliance. It was concluded that the Ten Hour Force Theory is valid because use of Class II elastics did not influence mandibular teeth position.
263

Desempenho operacional de semeadora-adubadorae perdas na colheita do milho em sistema de plantio direto/

Grotta, Danilo Cesar Checchio. January 2008 (has links)
Resumo: O objetivo buscado com o desenvolvimento do trabalho foi obter informações quanto às melhores alternativas para o sistema de semeadura direta em regiões com características semelhantes às de Jaboticabal/SP, na cultura do milho, em diferentes manejos de culturas de cobertura do solo. O experimento foi conduzido na área experimental do Laboratório de Máquinas e Mecanização Agrícola (LAMMA) da UNESP/Jaboticabal. Avaliou-se o desempenho do conjunto trator-semeadora-adubadora, o desenvolvimento de um híbrido simples de milho (DKB 390), e as perdas na colheita mecanizada em função de 2 culturas de cobertura crotalária (Crotalária juncea L.) e mucuna preta (Mucuna aterrina L.), manejadas de 3 formas, sendo duas mecânicas (triturador de palhas e rolo-faca) e uma química (herbicida via pulverizador) com a cultura do milho semeada a 5 cm de profundidade e deposição de adubo em 3 profundidades (11, 14 e 17 cm) totalizando 18 tratamentos com 4 repetições com delineamento em blocos ao acaso, em esquema fatorial. Os resultados evidenciaram que a força de tração na barra foi menor nas profundidades 11 e 14 cm do sulcador de adubo, e o mesmo ocorreu para a força de tração na barra por fileira de semeadura, força de pico na barra de tração, potência na barra de tração, potência na barra por fileira de semeadura, consumos volumétrico e ponderal. O consumo específico foi maior na profundidade de 11 cm do sulcador de adubo. A distribuição longitudinal de plantas não foi influenciada pelos fatores. Os fatores cultura, manejo e profundidade não influenciaram as variáveis, fluxo de grãos, fluxo de material não grão, fluxo total e perdas totais. As perdas totais não foram influenciadas por nenhum dos fatores estudados. / Abstract: The objective sought with the development of the work was to obtain information on the best alternatives to the no-tillage system sowing in regions with similar characteristics to those of Jaboticabal / SP, in the corn crop in different management cultures of soil cover. The experiment was conducted in the experimental area of the Laboratory of Machinery and Agricultural Mechanization (LAMMA) of São Paulo University State. It was evaluated the performance of all tractor-seeder-fertilizer, the development of a simple hybrid maize (DKB 390), and losses in mechanized harvesting crops in function of 2 coverage cultures (Crotalária juncea L.) and black mucuna ( Mucuna aterrina L.), managed in 3 ways, two mechanical (crusher of straw and roll-knife) and a chemical (herbicide spray route) with the corn crop sown to 5 cm deep and deposition of fertilizer in 3 depths ( 11, 14 and 17 cm) totaling 18 treatments with 4 repetitions with design in randomized blocks in factorial plots. The results showed that the force of traction in the bar was lower at depths of 11 to 14 cm stem of fertilizer, and the same occurred for the traction force on the bar by row of sowing, the power peak in the bar of traction, potency on the traction bar, potency on the traction bar by the row of sowing, consumption volumetric and weight. The specific consumption was higher in the depth of 11 cm from steam of fertilizer. The longitudinal distribution of plants was not influenced by factors. The factors culture, management and depth did not influence the variables of grain flow, flow of material non-grain, total flow and total losses. The total losses were not affected by any of the factors studied. / Orientador: Carlos Eduardo Angeli Furlani / Coorientador: Rouverson Pereira da Silva / Banca: Alberto Carvalho Filho / Banca: Wilson José Oliveira de Souza / Banca: Afonso Lopes / Banca: Leandro Borges Lemos / Doutor
264

Rate-dependent cohesive-zone models for fracture and fatigue

Salih, Sarmed January 2018 (has links)
Despite the phenomena of fracture and fatigue having been the focus of academic research for more than 150 years, it remains in effect an empirical science lacking a complete and comprehensive set of predictive solutions. In this regard, the focus of the research in this thesis is on the development of new cohesive-zone models for fracture and fatigue that are afforded an ability to capture strain-rate effects. For the case of monotonic fracture in ductile material, different combinations of material response are examined with rate effects appearing either in the bulk material or localised to the cohesive-zone or in both. The development of a new rate-dependent CZM required first an analysis of two existing methods for incorporating rate dependency, i.e.either via a temporal critical stress or a temporal critical separation. The analysis revealed unrealistic crack behaviour at high loading rates. The new rate-dependent cohesive model introduced in the thesis couples the temporal responses of critical stress and critical separation and is shown to provide a stable and realistic solution to dynamic fracture. For the case of fatigue, a new frequency-dependent cohesive-zone model (FDCZM) has been developed for the simulation of both high and low-cycle fatigue-crack growth in elasto-plastic material. The developed model provides an alternative approach that delivers the accuracy of the loading-unloading hysteresis damage model along with the computational efficiency of the equally well-established envelope load-damage model by incorporating a fast-track feature. With the fast-track procedure, a particular damage state for one loading cycle is 'frozen in' over a predefined number of cycles. Stress and strain states are subsequently updated followed by an update on the damage state in the representative loading cycle which again is 'frozen in' and applied over the same number of cycles. The process is repeated up to failure. The technique is shown to be highly efficient in terms of time and cost and is particularly effective when a large number of frozen cycles can be applied without significant loss of accuracy. To demonstrate the practical worth of the approach, the effect that the frequency has on fatigue crack growth in austenitic stainless-steel 304 is analysed. It is found that the crack growth rate (da/dN) decreases with increasing frequency up to a frequency of 5 Hz after which it levels off. The behaviour, which can be linked to martensitic phase transformation, is shown to be accurately captured by the new FDCZM.
265

Effet de la température sur les hétérogénéités de déformation plastique dans les alliages de magnésium / Effect of the temperature on the plastic deformation heterogeneities in magnesium alloys

Dessolier, Thibaut 07 December 2018 (has links)
L’objectif de cette étude est de quantifier la contribution intra et intergranulaire lors d’une sollicitation à haute température d’un alliage de magnésium (AZ31). Afin de répondre à cette problématique scientifique, un essai de traction in situ à haute température dans un MEB a été mis en place. Un important travail de développement a été réalisé autour de cet essai afin de lever un nombre de verrous technique conséquent. Ces verrous expliquent en partie pourquoi il existe aujourd’hui peu d’étude in situ à haute température sur des alliages de magnésium. Un marqueur local ayant la forme d’une microgrille a été déposé sur notre échantillon étant donné que celui-ci n’offre aucun contraste local pour la corrélation d’image numérique (CIN). Afin le dépôt du marqueur local, une cartographie EBSD a été réalisée. À l’aide des joints de grains issus de la carte EBSD, on peut venir superposer les joints de grains aux champs de déformation issue de la CIN.À l’aide des essais de traction in situ à haute température, on a pu mettre en avant l’effet de la température sur les différents mécanismes de déformation actif. Tout ce travail de développement nous permet ainsi de pouvoir localiser les hétérogénéités de déformation plastique à la fois en fonction de l’évolution de la déformation et pour plusieurs températures. D’après les essais menés, on a pu mettre en évidence le fait que plus la température est élevée, que plus les hétérogénéités de déformation plastique se localisent au voisinage des joints de grains. Basé sur une hypothèse cœur/manteau, on a pu venir quantifier la contribution intergranulaire, et mettre en avant que celle-ci devenait plus importante avec la température. / The aim of this study is to quantify the intra and intergranular contribution of the deformation during a high temperature micromechanical test on a magnesium alloy (AZ31). In order to answer this scientific issue, we have developed an in situ tensile test at high temperature within a SEM. It has required a significant preparation work in order to push the current technical limits of this type of test on magnesium alloy. These technical limits can partly explain why there are currently few in situ studies at high temperature on magnesium alloys. A local marker in the form of a microgrid was placed on our sample as it does not provide any local contrast for digital image correlation (DIC). Before the deposition of the microgrid, EBSD mapping was made. Using the grain boundaries from the EBSD, we can superimpose the deformed grain boundaries on the strain map from the DIC.Using high temperature in-situ tensile tests, we were able to highlight the effect of the temperature on the different active deformation mechanisms. This whole development work enables us to locate the plastic deformation heterogeneities both according to the evolution of the deformation and for several temperatures. From the tests conducted, it has been shown that the higher the temperature, the more heterogeneous the plastic deformation heterogeneities are located in the vicinity of the grain boundaries. Based on a heart/coat hypothesis, we were able to quantify the intra and intergranular contribution, and show that it became more important with temperature.
266

Projeto e dimensionamento de um sistema de tração para veículos elétricos

Wiltuschnig, Igor Pasa January 2016 (has links)
O presente trabalho tem por objetivo propor uma metodologia para o dimensionamento da potência tracionária em função do percurso percorrido por veículos elétricos, assim como realizar o projeto básico de uma máquina elétrica para suprir a carga tracionária exigida. Os cálculos foram realizados através de um algoritmo onde o usuário insere as variáveis mecânicas do veículo e recebe a potência e conjugado necessários, e o projeto elementar da máquina que deverá equipar o veículo. Realizou-se um estudo de caso a partir de uma scooter elétrica para validar os resultados, foi projetada uma máquina brushless dc com fluxo radial e rotor externo. Os resultados experimentais atenderam as espectativas de conjugado de 46 Nm, o máximo conjugado estático atingiu 48 Nm e a rotação a vazio obteve valor de 613 rpm à tensão nominal. Os ensaios de frenagem regenerativa com supercapacitores apresentaram resultados promissores com 50% da energia mecânica recebida durante a frenagem entregue na partida do veículo. / The present study aims to propose a methodology for the design of power traction depending on the distance traveled by electrical vehicles, and perform the basic design of an electrical machine to supply the traction load required. The calculations will be performed through an algorithm where the user enters the mechanical variables of the vehicle and receives the power and torque required and the basic machine design that should equip the vehicle. A case study was conducted for an electric scooter considering the designed dc brushless machine with radial flow and external rotor in order to validate the results. The experimental results met the target of 46 Nm of torque, the maximum static torque 48 Nm was reached, and the no-load rotation obtained was 613 rpm at nominal voltage. Regenerative braking tests with super capacitors showed a promising result: 50% of the received mechanical energy during braking was delivered to the vehicle starting.
267

Técnica do tratamento restaurador atraumatico em estudantes de escola municipal do Rio de Janeiro: avaliação in vitro da influência da proteção superficial e do tempo de entrada em serviço na resistência a tração diametral do cimento de ionômero de vidro utilizado / Atraumatic restorative treatment realized in schoolchildren in municipal school RJ Brazil: in vitro evaluated of cohesive resistence and diametral traccion of the glass ionomer used

Eliane Ramos Toledo de Carvalho 05 February 2010 (has links)
Tratamento restaurador atraumático tornou-se uma opção real para o tratamento da cárie dentária em saúde pública no Brasil. O presente estudo teve como objetivo avaliar durabilidade, resistência e eficácia de 70 restaurações em 31 alunos (entre 6 a 12 anos de idade na Escola Municipal Rotary, RJ - Brasil). Depois de CPO-D e ceo-exame de acordo com critérios da OMS, todos os alunos com selecionados receberam TRA com VITRO MOLAR - DFL, juntamente com instruções de saúde bucal. Os critérios de exclusão foram a presença de cavidades muito profundas e exposição pulpar, casos em que os alunos foram encaminhados para o Postos de Saúde Municipal. In vitro avaliou-se a influência do tempo de entrada em serviço e do tipo de cobertura protetora utilizada na resistência coesiva do Cimento de Ionômero de Vidro utilizado, por meio de ensaios de tração diametral. Confeccionou-se para o teste de tração diametral 6 espécimes para cada variante, 72 no total, com dimensões de 4 mm de diâmetro por 8 mm de comprimento, divididos entre os grupos: grupo1 sem protetor (controle); grupo2 vaselina sólida; grupo3 verniz para unhas. Realizou-se ensaios mecânicos em uma máquina universal de ensaios EMIC DL 500 MF, após a confecção e estocagem individual dos espécimes em potes plásticos contendo 5 ml de água deionizada, que formaram os subgrupos descritos a seguir: a - 20 minutos; b - 2 horas; c - 24 horas; d - 7 dias. Os dados obtidos foram tratados por ANOVA e por Student Newman-Keuls (p<0,05). Ao se avaliar a influência dos diferentes protetores de superfície no CIV utilizado no presente trabalho observou-se que, os protetores de superfície tiveram influência no comportamento do material (p=0,000), com o verniz para unhas mostrando um desempenho superior ao da vaselina sólida. Quanto ao tempo, não foi possível verificar ruptura do material no prazo de 20 minutos, pois os corpos de prova sofriam deformação elástica catastrófica não sendo adequado para a finalidade desejada. Os tempos de 24 horas e sete dias foram semelhantes entre si e diferentes do tempo de duas horas. As restaurações foram clinicamente avaliadas depois de 6, 12, e 24 meses após sua alocação. No total 72 restaurações foram realizadas em 31 escolares. Depois de seis meses, 5 restaurações fraturaram e 3 perderam algum material. Após 12 meses, oito restaurações foram perdidas e apenas 1 fraturou. Na avaliação após 24 meses, mais 12 restaurações foram perdidas e 3 perderam material. Não foram registradas lesões cariosas secundarias após esse período, mesmo quando as restaurações foram parcialmente perdidas. Clinicamente conclui-se que quando a técnica do TRA é bem indicada e aplicada corretamente pode haver uma redução significativa no número de dentes perdidos por lesões de cárie nos indivíduos que participaram do nosso estudo. / Atraumatic restorative treatment (ART) has become a real option for caries treatment in public health in Brazil. The present study aimed to evaluate the durability, the resistance, and the effectiveness of ART restorations in vivo in 31 students (ages 6 to 12 yrs old at the Municipal Rotary School, RJ - Brazil). After DMF-T and dmf-t examination according to WHO criteria, all students with dental cavities received ART with VITRO MOLAR - DFL, along with oral health instruction. In vitro were evaluated the influence of time of entry into service and the type of protective covering used in the cohesive strength of the cement Glass Ionomer used by diametral tensile (TD).The glass iomer was manipulates according manufacture instructions and divided in three groups 1-without protector(control) G2-with solid vaseline and G3- nails varnish. Exclusion criteria were the presence of very deep cavities and exposed pulp exposition, in which cases the students were referred to the Municipality Health Care. For the traction tests, it was confectioned 6 specimens measuring 4 mm of diameter and 8 mm of lengths, individually storage in plastic tubs with 5ml of deodenized water. The mechanic trials were done in a universal machine EMIC DL 500 MF. Data were analyzed by ANOVA and Student Newman-Keuls (p<0,05). The influence of different protectors in the Glass Inomer,in the present work, it was observed that they had few influence in the material behavior, most f the time similar to the control group and the material suffer distortion when under a 20 minutes traction. The restorations were clinically observed after 6, 12, and 24 mos. In total, 72 restorations were made in 31 students. After 6 months, 5 restorations were fractured and 3 presented with some material lost. At 12 months, 8 more restorations were lost, only 1 was fractured, and 7 had lost some material. After 24 months, 12 more restorations were lost, 3 had lost some material. Although not all restorations could be evaluated until 24 months, no secondary caries was detected, even when the fillings were (partly) affected. This glass ionomer, when used in an ART setting, was successful in avoiding dental caries and its progression for at least one year, and therefore we recommend its use in areas with limited or no access to dental care.
268

Desempenho de semeadora-adubadora com cinco modelos de hastes sulcadoras na cultura do milho (Zea mays L.) /

Canova, Ricardo. January 2010 (has links)
Orientador: Carlos Eduardo Angeli Furlani / Banca: Rouverson Pereira da Silva / Banca: Danilo César Checchio Grotta / Resumo: O uso de sulcadores do tipo haste nas semeadoras-adubadoras utilizadas no plantio direto tem se generalizado, principalmente em áreas de solos argilosos, como alternativa para romper a camada superficial mais compactada. Entretanto, em determinadas condições a eficiência da haste sulcadora não se mantém, devido às características relacionadas ao solo, a semeadura e até mesmo ao próprio sistema de preparo. Portanto, o objetivo do trabalho foi avaliar o desempenho de cinco modelos de hastes sulcadoras, distribuição longitudinal de sementes e o desempenho da cultura utilizando uma semeadora-adubadora em sistema plantio direto. O experimento foi conduzido no campo experimental da empresa Jumil, na cidade de Batatais - SP, com altitude e declividade médias de 862 m e 4%, respectivamente. Foi utilizada uma semeadora-adubadora da marca Jumil, modelo Guerra JM 7090 EX com cinco unidades de semeadura, espaçadas de 0,70 m e acoplada a um trator com tração 4x2 TDA. A semeadura do milho foi realizada sobre palhada de braquiária (Brachiaria decumbens Stapf). Os parâmetros avaliados foram força de tração média e de pico na barra, potência na barra de tração, profundidade de deposição do adubo, emergência de plântulas, distribuição longitudinal, estande inicial e final, produtividade, remoção de solo e capacidade de campo efetiva. A haste sulcadora com formato parabólico apresentou menor demanda de força de tração e potência na barra e a semeadora-adubadora utilizada para todas as hastes sulcadoras avaliadas, apresentou ótima distribuição de espaçamentos normais na distribuição longitudinal de sementes / Abstract: The use of planter chisel type openers in no-tillage has been generalized, mainly in areas with clay soils as an alternative to break the most compact superficial layer. However, in some conditions the efficiency of the planter chisel openers it is not kept due to the characteristics of the soil, sowing and even the tillage system. Thus the aim of this work is to evaluate the performance of five different openers for planter chisel, seeds longitudinal distribution of no-tillage. The experiment was conducted in the experimental field of the company Jumil, in the city of Batatais, SP, with average altitude and slope of 862 m and 4%, respectively. It was used a planter chisel with the brand of Jumil Guerra JM7090 EX with five units of tillage, with 0.70m one from the other and attached to a tractor with 4x2 wheel drive TDA. The corn sowing was done on Brachiaria decumbens Stapf. The parameters analyzed were average traction and peak in the coupling, power in the coupling, profundity of the fertilizer deposition, seedlings emergence, longitudinal distribution, initial and final stand, productivity, soil removing and effective capacity of field. The opener with the parabolic format presented less demand of traction and power in the coupling and the planter chisel used presented a good distribution of normal spaces in the longitudinal distribution of seeds / Mestre
269

CARACTÉRISATION MÉCANIQUE DES MATÉRIAUX EN FAIBLE ÉPAISSEUR PAR INTERFÉROMÉTRIE NUMÉRIQUE. APPLICATION AUX ESSAIS DE GONFLEMENT ET DE TRACTION.

Poilâne, Christophe 22 December 1998 (has links) (PDF)
La thèse est consacrée à la caractérisation mécanique des films minces à l'aide de mesures de déplacements par voie optique et traitements numériques. Les domaines d'études sont d'une part les contraintes résiduelles et d'autre part l'essai de traction. Les moyens de mesure employés sont la projection de franges et la photographie numérique de speckle.<br /><br />La projection de franges permet de mesurer la carte des déplacement hors-plan. Elle est adaptée à la mesure des contraintes résiduelles dans les films minces par analyses de courbure et/ou essais de gonflement. On montre suite à trois études expérimentales :<br />1. la précaution à prendre dans l'utilisation de la formule de Stoney même pour des bicouches libre-libre (SiO2/Si) ;<br />2. la présence de flambage dans les membranes bicouches comprimées encastré-encastré (SiO2/Si) ;<br />3. un parfait accord entre essais de gonflement et essais de nano-indentation pour des films tendus (polimiide).<br /><br />La photographie numérique de speckle permet de mesurer la carte des déplacements dans le plan. Elle est adaptée avec succès à un banc d'essais de traction conçu durant la thèse et spécialement dédié aux films minces. Un algorithme original de calcul a été développé pour obtenir une résolution subpixel. Les performances de l'algorithme sont comparées par des simulations et des expériences aux algorithmes classiques de corrélation. Sa rapidité et sa haute résolution permettent de calculer les cartes de déplacements en temps réel. Les déformations dans le plan en sont déduites et permettent le tracé des courbes contrainte/déformation puis le calcul du module d'Young E et du coefficient de Poisson v. Les matériaux choisis pour valider le banc d'essai sont le cuivre électrodéposé, matériaux ductile, puis le silicium monocristallin, matériaux fragile.
270

Cristallisation des caoutchoucs chargés et non chargés sous contrainte : Effet sur les chaines amorphes

Marchal, Jeanne 21 June 2006 (has links) (PDF)
Nous avons étudié les propriétés de cristallisation sous traction du 1,4 poly-cis-isoprène naturel (CN) en<br />fonction de la température, du taux de réticulation et du pourcentage de charge ajoutée (noir de carbone). Le<br />taux de cristallinité a été mesuré par diffraction X et l'orientation des chaînes polymères dans la phase<br />amorphe par RMNdu deutérium. Nous avons pu établir que l'hystérésis mécanique observée lors d'un cycle<br />de traction était essentiellement due au phénomène de cristallisation sous traction. Dans le cas des<br />échantillons non chargés, le début de la cristallisation se traduit par un adoucissement de la contrainte ; ceci<br />est observé jusqu'à une cristallinité de 15% environ, au-delà de laquelle on observe au contraire un<br />durcissement apparaissant à une extension critique qui varie selon le matériau et les adjuvants contenus dans<br />le caoutchouc. Durant la phase de décharge, on observe fréquemment une instabilité géométrique<br />correspondant à la séparation macroscopique d'une phase amorphe et d'une phase semi-cristalline<br />(« striction inverse ») ; cet effet a été étudié en détail. Il est vraisemblable que le même phénomène de<br />micro-striction se produise localement dans les matériaux où la striction inverse n'est pas visible. Dans le<br />cas des matériaux chargés, seule la phase de durcissement est visible.<br />La quantité d'énergie dissipée H liée à l'hystérésis mécanique n'est fonction que du taux de cristallinité<br />maximale Cmax atteint durant le cycle. Nous avons montré que la composante viscoélastique de cette<br />hystérésis est faible (Hvisco<10% lorsqu'il y a cristallisation) : la résistance à la rupture de ces matériaux est<br />donc essentiellement due à la cristallisation sous contrainte.<br />Nous avons en outre pu établir que dans les matériaux chargés, l'effet de durcissement dû à la cristallisation<br />était fortement amplifié par la présence des charges.<br />Dans la cas de matériaux non chargés, la RMN a permis de mettre en évidence la relaxation des chaînes due<br />à la cristallisation : ce phénomène est observé y compris dans la phase de durcissement.<br />Des études complémentaires ont été menées sur d'autres types d'élastomères : polybutadiène,<br />polychloroprène, butyl ... Le lien entre renforcement et cristallisation a pu également y être mis en<br />évidence.

Page generated in 0.1039 seconds