• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 299
  • 4
  • 4
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • 1
  • Tagged with
  • 302
  • 302
  • 154
  • 26
  • 26
  • 26
  • 26
  • 26
  • 25
  • 23
  • 23
  • 22
  • 20
  • 18
  • 17
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
241

Detecção de turbulências causadas por vórtices

Adriano Gustavo de Carvalho 17 December 2009 (has links)
O crescimento regular do tráfego aéreo mundial e a introdução de grandes aeronaves impuseram a necessidade de aumentar a capacidade dos aeroportos e, consequentemente, reduzir a separação mínima entre as aeronaves. Um fator limitante desta distância mínima é a geração de vórtices de ponta de asa das aeronaves, cujas turbulências geradas pelo escoamento através das asas são mais intensas em aeronaves de grande porte. Este trabalho visa a explicação do fenômeno de geração de vórtices de ponta de asa, assim como suas consequências, aplicações tecnológicas que auxiliam na detecção deste fenômeno, melhorias na segurança de vôo (Safety assessment) e o impacto econômico gerado em aeroportos e operadoras. Diversas técnicas estão sendo desenvolvidas para a detecção e previsão das turbulências geradas pelos vórtices, sendo as principais: LIDAR (Light Detection and Ranging), Detecção acústica e Ultra-som. Além do conhecimento acadêmico desenvolvido, esta dissertação tem por finalidade capacitar tecnicamente o setor aeronáutico no sentido de conhecer novos sistemas (em aeronaves e aeroportos) economicamente viáveis que possam ser aplicados no gerenciamento do tráfego aéreo.
242

Desenvolvimento de sistema de sensoriamento de posição e atuação para posicionamento dinâmico de modelos reduzidos em tanque de provas. / Development of both sensing and actuation infra-structure for the performance evaluation of Dynamic Positioning Systems for reduced scale model of ships in towing tanks or offshore tanks.

Santos, Alessandro de Oliveira 28 March 2005 (has links)
Este trabalho tem como objetivo central o desenvolvimento da infra-estrutura de sensoriamento e atuação para a avaliação de Sistemas de Posicionamento Dinâmico de modelos reduzidos de embarcações em tanques de provas. Ele descreve a concepção, o projeto, a implementação e os testes de um sistema sensor de posição e orientação do modelo, assim como o hardware dos propulsores utilizados como atuadores do modelo. O sistema sensor é baseado na emissão e recepção de sinais acústicos sincronizados de alta freqüência (ultra-som). Utiliza-se o Método Esférico 3-D como algoritmo de triangularização, obtendo-se a estimativa da posição por meio da minimização de uma medida quadrática do erro. Além disso, foi também aplicado o filtro estendido de Kalman como algoritmo de estimação. São apresentadas de forma clara e objetiva as dificuldades encontradas no decorrer do desenvolvimento do trabalho, bem como as soluções adotadas para contorná-las, analisando as influências das condições atmosféricas e do ambiente laboratorial no processo de medição, os resultados obtidos a partir dos ensaios, a robustez e o desempenho do sistema sensor. / The main objective of this work is the development of both sensing and actuation infra-structure for the performance evaluation of Dynamic Positioning Systems for reduced scale model of ships in towing tanks or offshore tanks. It describes the conception, design, implementation and tests of a range and orientation sensor system, as well as the hardware of the propellers used as the model actuators. The sensor system is based on the emission and reception of high frequency synchronized accoustic signals (ultra-sound). A 3-D spherical method based on the minimization of a quadratic measure of the error is used to estimate the position of the ship model. Furthermore the extended Kalman filter is also used. The difficulties found during the development of the project are presented as well as the solutions adopted to circumvent them. The experimental results obtained are discussed. In particular, the influence of both the local atmosphere and the lab environment on the performance of the sensor system are taken into account.
243

Previsão pré-operatória do estadiamento local do câncer prostático: análise multifatorial baseada em parâmetros clínicos, laboratoriais e de imagem por ressonância magnética e ultra-sonografia / Preoperative prediction of local staging of prostate cancer: multifactorial analysis based on clinical, laboratory and imaging parameters by magnetic resonance and ultrasonography

Ferreira, Daniel Miranda 09 August 2005 (has links)
INTRODUÇÃO: O câncer de próstata ocupa o segundo lugar entre as neoplasias de maior incidência na população masculina mundial. Uma vez estabelecido o diagnóstico, o estadiamento passa a ter papel fundamental na escolha da opção e tática terapêuticas. OBJETIVO: Avaliar as diferenças clínicas, laboratoriais e anatomopatológicas dos pacientes e determinar a acurácia, a sensibilidade, a especificidade e os valores preditivos positivo e negativo de vários exames pré-operatórios, avaliando isoladamente e em conjunto aqueles capazes de melhor prever o estadiamento local do câncer prostático. MÉTODOS: Foram analisados o antígeno prostático específico (PSA), as densidades de PSA calculadas pelos exames de ressonância magnética e ultra-som (DPSA), a graduação de Gleason, o número de sextantes positivos e a porcentagem de fragmentos positivos nas biópsias, as probabilidades de doença intraprostática, doença extracapsular e comprometimento das vesículas seminais segundo os nomogramas de Kattan e Partin, e os resultados dos exames de toque retal, da ressonância magnética com bobina endorretal e do ultra-som com Doppler de amplitude em relação ao estadiamento do câncer de próstata em 49 pacientes submetidos à prostatectomia radical. Os resultados foram comparados com os resultados anatomopatológicos. RESULTADOS: Dos 49 pacientes com tumores classificados clinicamente como intraprostáticos, respectivamente 59,2 %, 51,0 % e 32,7 % dos pacientes foram subestadiados clinicamente em relação à doença extraprostática, doença extracapsular e comprometimento das vesículas seminais. Estadiamentos clínicos iniciais tiveram taxas de subestadiamento menores e estadiamentos clínicos mais avançados tiveram taxas de subestadiamento maiores. As médias da maioria dos parâmetros clínicos e laboratoriais dos pacientes com doença avançada apresentaram valores maiores do que as médias dos pacientes com doença localizada. A biópsia prostática superestimou a graduação histopatológica final de Gleason em 10,2 % dos casos, subestimou a graduação em 49,0 % dos casos e a correlação foi idêntica em 40,8 %. A ressonância magnética, quando comparada aos outros parâmetros analisados de forma isolada, apresentou os maiores valores de acurácia na discriminação doença intraprostática x doença extraprostática (73,5 %), doença intracapsular x doença extracapsular (81,6 %) e comprometimento ou não das vesículas seminais (77,6 %). A acurácia geral dos modelos de regressão logística baseada nas variáveis contempladas foi de 71,4 % na previsão de doença extraprostática, 87,2 % na previsão de doença extracapsular e 81,0 % na previsão de comprometimento das vesículas seminais. CONCLUSÃO: A ressonância magnética com bobina endorretal se mostrou ser um dos melhores métodos para o estadiamento local do câncer de próstata e pode ser considerada no estudo de pacientes selecionados / INTRODUCTION: The prostate cancer is the second more frequent neoplasia in the worldwide male population. Since the diagnosis is established, the staging has a fundamental role on the choice of therapeutic option and tactics. OBJECTIVE: To evaluate the clinical, laboratory and anatomopathological differences of patients and determine the accuracy, sensitiveness, specificity and positive and negative predictive values of several preoperative examinations, by evaluating individually and conjointly those which are able to better predict the local staging of prostate cancer. METHODS: The prostate-specific antigen (PSA) was analyzed as well as the PSA densities (PSAD) were calculated through the magnetic resonance and ultrasound, the Gleason\'s grading, the number of positive sextants and the percentage of positive fragments in biopsies, the probabilities of intraprostatic disease, extracapsular disease and involvement of seminal vesicles according to Kattan and Partin\'s nomograms, and the results of rectal palpations, the use of endorectal coil magnetic resonance imaging and the use of amplitude Doppler ultrasound in relation to the staging of prostate cancer in 49 patients who were submitted to radical prostatectomy. The results were compared with the anatomopathological results. RESULTS: Among 49 patients with tumors clinically classified as intraprostatic, 59.2%, 51.0% and 32.7% patients respectively were clinically understaged in relation to extraprostatic disease, extracapsular disease and involvement of seminal vesicles. The initial clinical staging had lower substaging rates and the more advanced clinical staging had higher substaging rates. The averages of most clinical and laboratory parameters of patients with advanced disease presented values higher than the averages of patients with localized disease. The prostatic biopsy overestimated the Gleason\'s final histopathologic grade in 10.2% of cases, underestimated the grade in 49.0 % of cases and had identical correlation in 40.8%. The magnetic resonance imaging, when compared with all of other parameters analyzed isolately, presented the highest accuracy values in the discrimination intraprostatic disease x extraprostatic disease (73.5%), intracapsular disease x extracapsular disease (81.6 %) and the presence of seminal vesicles involvement (77.6%). The general accuracy of logistic regression models based on contemplated variables was of 71.4% in the extraprostatic disease prediction, 87.2% in the extracapsular disease prediction and 81.0% in the prediction of involvement of seminal vesicles. CONCLUSION: The use of endorectal coil magnetic resonance imaging was one of the best predictors of local staging of prostate cancer and could be considered in the study of selected patients
244

Aplicação de lise celular forçada em sistema de tratamento aeróbio precedido de reator UASB

Parsekian, Marilú Pereira Serafim 09 May 2003 (has links)
Este estudo visou avaliar as implicações do uso da lise celular sobre a produção de lodos e acumulação de nutrientes no efluente do sistema combinado de tratamento (anaeróbio/aeróbio) de despejo sintético simulando esgoto sanitário. O sistema operado era constituído de reator UASB (V = 10,5 l), reator aeróbio (V = 4,4 l) e sedimentador (V = 2,7 l), operando com tempo de detenção hidráulica de 8,0 h, 3,5 h e 2,7 h respectivamente. Durante a fase de controle, acompanhou-se as características de funcionamento do processo sem o emprego da lise celular no lodo de excesso e posteriormente fez-se uso de equipamento de ultra-som para promover a lise do lodo, com retorno posterior do lodo lisado à entrada do reator UASB. Verificou-se que a eficiência média global de remoção de DQO do sistema foi de 90% em ambas as fases considerando DQO efluente filtrada. A conversão de nitrogênio amoniacal a nitrato foi pequena no tanque de aeração e a remoção de fósforo foi insignificante no processo de tratamento, no entanto não ocorreu alteração na qualidade do efluente do sistema em função do retorno do material lisado. Na escala estudada foi freqüente o aparecimento de bulking (controlado pela aplicação de hipoclorito de sódio no sedimentador), fato esse que dificultou a operação do sistema de tratamento e interferiu na manutenção do tempo de retenção celular. Os resultados obtidos da simulação realizada por meio do software GPS-X 4.0, para reator em escala real empregando a lise celular, mostraram acréscimo na concentração de fósforo total no efluente de 30% após 5 anos de operação / The aim of this research is to value the use of cell lyses over the sludge production and effluent nutrient accumulation from a combined treatment system (anaerobic/aerobic) from a synthetic sanitary wastewater. The parts of this system where one UASB reactor (V = 10,5 l), one aeration tank (V = 4,4 l) and one sedimentation tank (V = 2,7 l), hydraulic detention times of 8,0 h, 3,5 h e 2,7 h, respectively. During the control period, the characteristics of the system working without the use of cell lyses were recorded. After this phase, ultrasound equipment was used to cause the sludge lyses and then the sludge was returned to the entrance of the UASB reactor. From these tests we could not observe changes in mean global DQO removal efficiency for the both phases and it was 90% considering filtrated effluent COD. Few ammonia-nitrogen changes into nitrate inside the aeration tank were observed. Phosphorus removal in the treatment system was insignificant, but we could notice no damage to the treatment system caused by the lyses material returned. In the reduced scale of the system bulking events were frequent. This was controlled with sodium hypochlorite at the sedimentation tank, but these events caused operation difficulties and had interfered on the cellular detention time maintenance. Results from a real scale simulation, using cell lyses, done with the GPS-X 4.0 software, show an increase in effluent total phosphorus equal to 30% after 5 years
245

A importância de alguns adesivos dentais e de vários tratamentos da superfície sobre a dentina humana in vitro. Análise da resistência adesiva por micro-cisalhamento / The relevance of some dental adhesives and different surface instrumentations on human dentin (in vitro). Micro-shear bond strength analyses

Macedo, Manoel Roberto de Paula 05 December 2008 (has links)
O objetivo deste trabalho foi estudar a ação sobre a dentina humana (in vitro) de vários tratamentos de superfície: Lixa, IADR-GM, CVDt e CVDi e de alguns adesivos dentais: Adper Sigle Bond 2 (SB), Clearfil SE Bond (CF) e Adper Prompt L-Pop (PL) avaliando: rugosidade e resistência adesiva por micro-cisalhamento. Foram utilizados 72 terceiros molares hígidos que foram divididos ao meio. As superfícies oclusais das 144 metades dentais foram removidas e padronizadas com Lixa #600. Após receberem os tratamentos de superfície citados, foi avaliada a rugosidade média superficial (Ra) da dentina. Em seguida realizou-se a hibridização e a confecção dos cilindros de resina composta (RC) para finalizar o preparo dos corpos de prova (cps). Após armazenagem de 24h em água destilada a 370C realizou-se o teste de micro-cisalhamento com velocidade de deslocamento de 1mm/min. Os resultados foram submetidos a testes de analise estatística (ANOVA) onde foi comprovado que a menor Ra foi encontrada nas superfícies instrumentadas com Lixa #600 seguida pelo CVDi, IADR-GM que apresentaram rugosidade intermediaria e se igualaram e pelo CVDt que produziram as superfícies mais rugosas. Já para o tratamento de superfície, o CVDi foi que apontou os piores valores de resistência de adesão que com Lixa e IADR-GM. Nos resultados para os adesivos, o PL apresentou valores de resistência à união inferiores ao SB e CF que se igualaram. Já para a interação entre os tratamentos de superfície e os adesivos não houve diferenças estatisticamente significantes entre os grupos tratados com Lixa #600, IADR-GM e CVDt e hibridizados com SB ou CF. Concluiu-se: que a Ra produzida em dentina pelo CVD variou de acordo com o tipo de movimento (CVDt produz maior rugosidade que o CVDi); que não foi possível estabelecer uma correlação entre Ra e valores de resistência adesiva; que o PL apresentou valores de resistência à adesão inferiores aos obtidos pelos adesivos SB e CF; que a interação dos tratamentos Lixa, IADR-GM e CVDt com os três adesivos (SB, CF, PL) mostrou valores mais altos para o SB e CF que se igualaram e menores para o PL; que o fator tratamento não produziu diferença de resistência adesiva para o adesivo CF e o mesmo ocorreu com o PL. / The aim of this in vitro study was to evaluate the micro-shear bond strength and the roughness to human dentin using different instrumentations (SiC #600, diamond rotary bur, CVDt and CVDi) and three dentin adhesive/composite resin systems: Adper Sigle Bond 2 (SB), Clearfil SE Bond (CF) e Adper Prompt L-Pop (PL). Seventy-two third molars were split in the middle. The oclusal third from the one hundred and forty and four halves were removed and standardized using the SiC #600. After the prepared surfaces, which were analyzed the roughness average (Ra) with a surface perfilometer and hybridization. The specimens were then stored in distillated water for 24 hours at 370C. The specimens were then were attached to a micro-shear apparatus and subjected to a micro-shear strength test at a crosshead speed of 1mm/min until failure occurred. The two-way ANOVA indicated that there was significant differences in average roughness between the instrumentations which SiC #600 was the smoothest surface. No differences were detected between dentin surface prepared with diamond bur and CVDi (intermediate in the roughness assessment) and the CVDt gave the roughest surface. The bond strengths varied slightly, though dentin instrumentations with CVDi showed the lowest values than the surfaces prepared with SiC #600 and diamond bur. The bond strengths varied slightly, though adhesives, PL showed lower micro-shear bond strength than SB and CF, which were no significant relevance. The interaction of SiC #600, diamond bur and CVDt using SB and CF showed no significant difference in micro-shear bond strength and higher than PL. The instrumentation showed no significant differences in micro-shear bond strength using CF and PL.
246

Análise numérica e experimental dos efeitos da não-uniformidade da espessura em cascas finas cilíndricas rotativas. / Numerical and experimental analysis of the thickness non-uniformity effects in rotating circular cylindrical shells.

Brujas, Marco Antonio 17 May 2007 (has links)
Cascas cilíndricas circulares com uma pequena variação de espessura ao longo de seu comprimento, quando submetidas à rotação, apresentam em alguns casos, deslocamentos elásticos de sua superfície externa, tendendo a uma forma de um oval. O objetivo deste trabalho é estabelecer a relação entre a variação de espessura das cascas cilíndricas com a sua deformação devida às forças centrífugas medida durante a rotação utilizando-se dois enfoques, um experimental e outro numérico, no caso o método de elementos finitos (MEF). As cascas cilíndricas estudadas tiveram sua espessura de parede medidas por meio de aparelho de ultra-som, mas por serem fabricadas em ferro fundido cinzento, as suas lamelas de grafita atuam como refletores, o que torna a medição imprecisa. Os resultados da análise numérica encontrados se relacionam bem com os experimentais de maneira qualitativa, mas divergem na forma quantitativa. Modelos de cascas com variação de espessura imposta também foram criados e analisados usando-se o método de elementos finitos de forma a se avaliar o comportamento da casca cilíndrica sob diversas configurações de distribuição da variação da espessura. Sugere-se a pesquisa de novas tecnologias para medições por ultra-som de peças fabricadas de ferro fundido com grafita lamelar. Neste trabalho, a medição da forma oval foi feita utilizando-se sensores de proximidade do tipo \"eddy-current\". / Circular cylindrical shells with small thickness variations along their body, when submitted to rotation, present, in some cases, elastic displacements of their outside surface induced by centrifugal forces leading to final oval like shapes. The main purpose of this study is to establish relationships between thickness variation of the cylindrical shells with their measured deformation during the rotation, due to centrifugal forces, using two approaches, one experimental and the other one numerical, in the latter case the finite element method (FEM). The studied cylindrical shells had their wall thickness measured by means of an ultrasound device. The used material is flake graphite cast iron (gray cast iron). The graphite flakes act as reflectors, what makes such measurements imprecise. The numerical results found are satisfactory in a qualitative way, but they disagree in the quantitative form. Shell models with theoretical imperfections also were created and analyzed using the finite element method in order to evaluate the behavior of the cylindrical shell under several configurations of distribution of the shell thickness variation. Further research is necessary on new technologies to measure the thickness of pieces manufactured of flake graphite cast iron. In this research, the oval shape measurements were done by means of eddy-current proximity sensors.
247

Efeito do ultrassom contínuo sobre o processo de regeneração do tecido conjuntivo muscular de ratos / Effects of continuous ultrasound onto the conjunctive muscular tissue regeneration process in rats

Fernandes, Bernardo Luiz Ferreira 15 April 2010 (has links)
Introdução: A escolha de parâmetros mais eficientes na aplicação terapêutica de um recurso de eletroterapia garante uma efetividade clínica maior ao tratamento realizado. O modo contínuo de aplicação do ultrassom vem sendo pouco estudado nas fases agudas das lesões. Objetivo: Avaliar os efeitos do ultrassom contínuo nas fases inflamatória, proliferativa e de remodelação no processo de regeneração do tecido conjuntivo muscular de ratos. Material e Métodos: Trinta ratos foram submetidos à lesão muscular nos músculos tibial anterior de ambos os membros traseiros e divididos em dois grupos, sendo o grupo Lesado (L) composto pelos membros traseiros esquerdos dos animais e o grupo lesado tratado com ultrassom (LUS), composto pelos membros traseiros direitos. Cada grupo foi subdividido em seis pequenos grupos (n = 5), que foram formados de acordo com o número de dias após a lesão em que os animais foram mortos, sendo no 3º, 7º, 14º, 21º, 28º e 35º dias. Após 24 horas da realização da lesão cirúrgica, o Grupo LUS começou a receber a aplicação do ultrassom no modo contínuo, área de radiação efetiva de 1cm2, com freqüência de transdutor de 1MHz, intensidade de 0,2W/cm2, por 1 minuto, uma vez ao dia. Os membros traseiros esquerdos submetidos à lesão cirúrgica e não tratados serviram como grupo controle (L). Para análise morfológica das fibras musculares foram realizados cortes seriados de 10 ?m de espessura, obtidos através de em um micrótomo criostato. Os músculos foram congelados em uma posição onde os cortes pudessem fornecer imagens longitudinais das fibras musculares e da fenda incisional. Cada série de corte foi obtida a partir da região superficial do músculo, a cada 100 ?m de profundidade e forneceu duas lâminas que foram coradas com a técnica Hematoxilina Eosina. A contagem de células foi feita em uma área de 0,625mm2 (área de um campo microscópico), com auxílio de uma câmera acoplada ao microscópio e monitor de vídeo e tendo como ponto de referência os limites da fenda incisional, ou seja, a região com fibras musculares lesionadas de um lado e as células infiltradas na fenda incisional de outro. A determinação da densidade de leucócitos polimorfonucleares e mononucleares, e de fibroblastos foi feita através da contagem média de 10 campos por amostra, sendo cinco campos representativos do tecido muscular seccionado e cinco campos da fenda incisional, totalizando 300 campos por grupo experimental (30 ratos ao todo). As células com morfologia de células satélites ou mioblastos foram ignoradas. Resultados: A análise da contagem de células revelou diferenças significativas (p <= 0,05) entre o número de células polimorfonucleares no 3º, 7º, 21º e 28º dias de tratamento com as seguintes xiii médias: L3 = 27,0; L7 = 29,6; L21 = 20,0 e L28 = 12,8 e LUS3 = 43,2; LUS7 = 29,2; LUS21 = 8,8 e LUS28 = 3,6. O número de fibroblastos foi significativamente maior (p<=0,05) apenas no 21º dia com L21 = 14,2 e LUS21 = 27,0. Conclusão: O ultrassom contínuo promoveu um aumento na densidade de células polimorfonucleares e fibroblastos durante o processo de regeneração do músculo tibial anterior de ratos, incrementando a recuperação deste tecido. / Introduction: The choice of more efficient parameters in the ultrasound application allows a major clinical effectivity to the performed treatment. The therapeutic continuous ultrasound has been being poorly studied in injury acute phases. Objective: To assess the effects of the continuous ultrasound in the inflammatory, proliferative and remodeling phases of rats\' conjunctive muscular tissue regeneration process. Material and Methods: Thirty rats were submitted to muscular lesion in tibialis anterior muscle of both rear limbs. They were divided into two groups, the lesion group (L) consisting of the rats left rear limbs, and the lesion group treated with ultrasound (LUS) consisting of the right rear limbs. Each group was subdivided into six small groups (n = 5), which were formed according to period of time (in days) after the lesion in which the rats were killed, on the 3rd, 7th, 14th, 21st, 28th and 35th days. Twenty four hours after performing the surgical lesion, the LUS group received the first 1MHz continuous ultrasound treatment with effective radiating area = 1cm2, intensity of 0.2W/cm2, for one minute, once a day. The left rear limbs submitted to the surgical lesion and not treated at all composed the control group (L). To perform the muscle fibers morphological analysis, a series of 10?m thick slices were made using a microtome with criostate. The muscles were frozen in a position which the slices could provide longitudinal images of the muscle fibers and incision gap. A series of samples were collected from the lesion area surface, and further two deeper series, at 100?m distance from one another. Two slices were thus provided and stained with hematoxilin-eosin. Cell count was made on an area of 0.625 mm2, by means of a camera coupled to the microscope and to a video monitor. The reference point were the limits of the incision gap, which is a region with injured muscle fibers in one side and infiltrated cells of the incision gap on the other. The determination of the density of polymorphonuclear and mononuclear leukocytes, and fibroblasts was made by the exam of 10 fields per sample (five fields representing the cut muscular tissue and more five fields of the incision gap), totaling 300 fields per group. Cells with myoblast or satellite cells morphology were ignored. Results: The cells counting analysis revealed significant differences (p <= 0.05) in the density of polymorphonuclear cells on the 3rd, 7th, 21st and 28th treatment days and the means are: L3 = 27; L7 = 29.6; L21 = 20; L28 = 12.8 and LUS3 = 43.2; LUS7 = 29.2; LUS21 = 8.8; LUS28 = 3.6. The density of fibroblasts was significant greater (p <= 0.05) only in the 21st day with means of L21 = 14.2 and LUS21 = 27. Conclusion: The continuous ultrasound increased the density of polymorphonuclear and fibroblasts cells during the anterior tibialis muscle regenerating process of rats, enhancing the recovery of this tissue.
248

Estimativa de características de carcaça e ponto ideal de abate por ultra-sonografia, em bovinos submetidos a diferentes níveis energéticos na ração. / Ultrasonography prediction of carcass characteristics and finishing of cattle fed different energy levels.

Silva, Saulo da Luz e 07 February 2002 (has links)
Este trabalho teve como objetivo avaliar Características de carcaça por ultra-sonografia de 48 animais confinados (24 Brangus e 24 Nelore), com sistema de controle de consumo individual através de portões eletrônicos(Calan Gates), recebendo diferentes níveis de energia na ração (20, 40, 60 e 80%). Foi utilizado um equipamento de ultra-som Piemedical Scanner 200 Vet, com transdutor linear de 18 cm e 3,5 MHz, a cada intervalo de aproximadamente 28 dias, para obter a área de olho de lombo (AOLU), espessura de gordura subcutânea (EGSU) entre a 12ª e a 13ª costelas e a espessura de gordura na picanha (EGPU), sob o terço superior do músculo Bíceps femuris. Após 142 dias de confinamento os animais foram abatidos e obteve-se o peso de carcaça quente (PCQ) e o rendimento de carcaça (RC). Após 24 horas de resfriamento, as carcaças foram cortadas entre a 12ª e a 13ª costelas e obtidas a área de olho de lombo (AOLC) e a espessura de gordura (EGSC) na carcaça. As correlações entre as medidas por ultra-som e na carcaça foram de 0,83 entre AOLU e AOLC e 0,86 entre EGSU e EGSC. Os animais Brangus apresentaram melhores respostas ao tratamento com 60% de concentrado, enquanto que os animais Nelore responderam melhor ao tratamento 40%. Equações de regressão utilizando o peso vivo (PV), AOLU, EGSU e EGPU explicaram 71% da variação do PCQ quando a medida foi realizada no início do experimento e cerca de 97% quando realizada imediatamente antes do abate, nos animais Brangus. Nos animais Nelore as equações explicaram cerca de 50% na medida realizada no início do trabalho e 96% na medida antes do abate. As equações para estimar o RC utilizando as mesmas características explicaram cerca de 28% da variação quando a medida foi realizada 142 dias antes do abate e 25%imediatamente antes do abate, nos animais Brangus. Nos animais Nelore, as equações explicaram cerca de 15% e 21% quando realizadas no início do experimento ou 142 dias depois, respectivamente. A estimativa da espessura de gordura subcutânea ao abate através do PV, AOLU, EGSU e EGPU explicaram cerca de 20% quando utilizados os dados obtidos no início do trabalho até 73% quando os dados utilizados foram os obtidos imediatamente antes do abate. As medidas de ultra-som apresentaram boa acurácia e podem ser utilizadas para estimar diferenças entre grupos de animais, mas as equações para estimar RC e ponto ideal de abate necessitam maiores estudos. / The objective of this experiment was to evaluate trough ultrasonography the carcass characteristics of 48 young bulls (24 Brangus and 24 Nellore), fed diets with four energy levels(20, 40, 60 and 80% of concentrate) in pens with Calan gates. The Piemedical Scanner 200 ultrasound with a linear transductor of 18 cm and 3,5 MHz was utilized, and the measurements taken at 28 days intervals of the rib eye area (AOLU) and subcutaneous fat thickness (EGSU) between the 12 th and 13 th ribs and also over the Biceps femoris muscle (EGPU). After 142 days on feed all the animals were slaughtered and the hot carcass weight (PCQ) was taken and the carcass dressing percentage (RC) calculated. After 24 hours of chilling the carcasses were separated between the 12 th and 13 th ribs and the rib eye area (AOLC) and fat thickness (EGSC) measured directly. The correlations between ultra-sound and carcass measurements were 0,83 for AOLU and AOLC and 0.86 for EGSU and EGSC. The Brangus bulls showed better performance with 60% concentrate diets and the Nellore with 40% concentrate diets. Regression equations using live weight (PV), AOLU, EGSU and EGPU explained 71% of the variation in the PCQ when measured 142 days before slaughter and 97% immediately before slaughter for the Brangus bulls. For the Nellore bulls the equations explained 50% in the first measurement and 96% the day before slaughter. The equations to estimate RC using the same ultrasound measurements explained 50 and 96% and 15 and 21% of the variation when taken 142 days before or in the day before slaughter for the Brangus and Nellore, respectively. To estimate a determined endpoint the PV, AOLU, EGSU and EGPU explained 20% of the variation when the data was taken in the beginning of the feeding period and increased up to 73 when the data were taken just before slaughter. The ultrasound measurements showed good accuracy and could be used to estimate differences among cattle groups, but equations to estimate RC and determined endpoint need further studies.
249

Efeitos do ultra-som pulsado de baixa intensidade sobre a cicatrização por segunda intenção de lesões cutâneas totais em ratos, mediante avaliação por planimetria. / Effects of low intensity pulsed ultrasound irradiation on the secondary healing of a round shaped total skin lesion in rats, assessd by means of planimetry.

Ferreira, Adriana da Silva 21 December 2005 (has links)
Foram avaliados os efeitos do ultra-som pulsado de baixa intensidade sobre a cicatrização de lesão cutânea produzida na região dorsal de ratos. Utilizamos 60 ratos machos (Wistar, peso médio de 300g) divididos em dois grupos de acordo com o tratamento, sendo: 1) irradiação simulada (controle); 2) irradiação efetiva (irradiado) Freqüência fundamental de 1,5MHz, freqüência de repetição de pulsos de 1KHz, largura de pulso de 200 µs, intensidade de 30mW/cm2 (SATA), 10 minutos de aplicação em dias alternados). Cada grupo foi subdividido em três grupos, de acordo com o período de irradiação ultrasônica; 3, 7 e 14 dias, e a cicatrização foi avaliada através de análise planimétrica. Aumento significante (p<0,05) da área cicatrizada foi observado no Grupo 2 (141,88±18,50 mm2) em relação ao Grupo 1 (117,38±15,14 mm2), no 14o dia. Não foram observadas diferenças entre os grupos nos outros tempos experimentais estudados. Concluiuse que o ultra-som pulsado de baixa intensidade não apresenta efeitos deletérios e estimula moderadamente a cicatrização cutânea por segunda intenção em condições experimentais, com potencial para aplicação clínica em humanos. Ainda, a planimetria, como método de companhamento da evolução da lesão cutânea, mostrou-se adequada e eficaz. / The effects of low intensity pulsed ultrasound irradiation on the secondary healing of a round shaped (1 cm in diameter) total skin lesion, produced on the dorsal region of rats, were studied. Sixty male Wistar rats weighing 300 g on average were used and divided into two groups of 30 animals each, according to treatment: Group 1, simulated irradiation (control); Group 2, effective irradiation (irradiated). 1.5 MHz fundamental frequency, 1 KHz pulse repetition frequency, 200 µs pulse width, 30mW/cm2 intensity (SATA), 10 minutes application in alternate days). Each group was divided into three subgroups: 3, 7 and 14 days, according to the postoperative period of ultrasound irradiation, and healing was evaluated by means of planimetry. The healed area was significantly increased (p<0.05) in Group 2 (141.88±18.50 mm2) as compared to Group 1 (117.38±15.14 mm2) on the 14th day. No differences were observed between subgroups for the other experimental periods. The author conclude that low intensity pulsed ultrasound irradiation presented virtually no deleterious effect and moderately stimulated secondary healing of total skin lesions in the experimental conditions of this investigation, with potential for clinical application in similar situations in humans. Also, planimetry showed to be effective method in evaluating the healing of skin lesions.
250

Estudo comparativo dos efeitos do ultra-som e do laser de baixa intensidade no reparo ósseo de tíbia de rato / Comparative study of ultra-sound and low intensity laser therapy effects on bone healing in rats tibia

Lirani, Ana Paula Rebucci 24 March 2004 (has links)
Vários estudos têm avaliado os efeitos do ultra-som e da radiação laser de baixa intensidade separadamente no reparo ósseo. No entanto, são escassas as comparações entre estas duas modalidades terapêuticas. Este estudo teve por objetivo avaliar e comparar, através de análise histomorfométrica e ensaio mecânico de flexão em três pontos, as conseqüências que estes agentes físicos podem trazer ao reparo do tecido ósseo em osteotomias transversais experimentais em tíbias de ratos. Foram utilizados 48 ratos com fratura cirúrgica unilateral parcial do terço superior de tíbia. Os animais foram divididos em três grupos de 16 animais. Em um grupo, o membro fraturado foi tratado com ultra-som pulsado de baixa intensidade (freqüência de 1,5 MHz, ciclo de trabalho 1:4, intensidade SATA 30 mW/centímetro quadrado) em sessões de 20 minutos, 5 vezes por semana, em 12 dias de tratamento. Em um segundo grupo, o membro fraturado foi tratado com laser As-Ga-Al (112,5 J/centímetro quadrado, 780 nm, 30 mW) em sessões de 2,5 minutos, 5 vezes por semana, em 12 dias de tratamento. O terceiro grupo serviu de controle, sendo submetido à mesma cirurgia na tíbia direita mas não recebeu qualquer tratamento. No ensaio mecânico, a carga no limite máximo suportada pelo grupo tratado com laser foi significantemente maior (p < 0,05) que os grupos tratado com ultra-som e controle. Na análise histomorfométrica, o grupo tratado com laser apresentou significância estatística quanto ao número e superfície de osteoblastos e volume e superfície de osteóide e o grupo ultra-som obteve significância para as superfícies de reabsorção e de osteoclastos. Pode-se concluir que o ultra-som acelerou o reparo ósseo (em relação ao grupo controle) por viabilizar mais rapidamente a fase de reabsorção, enquanto que a terapia laser foi capaz de acelerar ainda mais este processo por já promover predomínio de formação óssea no décimo nono dia pós-cirúrgico no modelo experimental utilizado neste estudo / Many studies have assessed the effects of ultra-sound and low intensity laser therapy separatedly in bone repair. However, the comparison between these two therapeutic modalities is rare. The objective of this study was to verify and compare, through histomorphometrical analysis and a three-point bending test, the consequences of these physical agents on bone healing in animals. 48 male Wistar rats were used with tibial bone partial osteotomy, divided into 3 groups of 16. In one group, rats had their fractured limb treated with GaAIAs laser (780 nm, 30 mW, 112,5 J/square contimeter) in 12 five times-a-week sections. In another group, rats were treated with low intensity pulsed ultra-sound (1,5 MHz, 30 mW/square centimeter) in 12 five times-a-week sections too. In a third group, animals were taken as control, being submitted to the same osteotomy but receiving no treatment. After 19 days the tibias were extracted and half of them were submitted to a three-point bending test and the other half to histomorphometric analysis. During the bending test, the maximum load at failure of the tibia in the laser group was significantly higher (p<0.05). Histomorphometry showed statistical significance in osteoblasts number and surface and osteoid volume and surface for the laser group, and eroded and osteoclasts surfaces for the ultra-sound group. Ultra-sound was able to enhance bone healing (compared to control group) by speeding up the reabsorption phase, while low intensity laser therapy could accelerate this process even more by promoting mostly new bone formation 19 days after osteotomy in this experimental model

Page generated in 0.0977 seconds