• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 43
  • Tagged with
  • 45
  • 27
  • 11
  • 11
  • 10
  • 10
  • 10
  • 8
  • 8
  • 8
  • 7
  • 6
  • 6
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Avaliação da efetividade de diferentes protocolos de irrigação na limpeza do canal radicular / Evaluation of the effectiveness of different irrigation protocols in the root canal cleaning

Fernandes, Samuel Lucas 15 June 2015 (has links)
O objetivo desse estudo foi avaliar a capacidade de dissolução e remoção de biofilme formado in situ, na remoção de smear layer e debris empregando dez protocolos de irrigação final (solução fisiológica com ou sem agitação ultrassônica; ou hipoclorito de sódio como irrigante primário, seguido de solução salina, ou EDTA 17%, ou ácido peracético (PAA) 2%, ou Qmix, com ou sem agitação ultrassônica de ambas as soluções). Duzentos e trinta raízes bovinas foram seccionadas e cortadas com 15mm de comprimento e instrumentadas com o instrumento Reciproc R50. Para a análise da remoção de debris e smear layer foram separadas 100 raízes, que foram clivadas e, no terço apical de uma das metades radiculares, foi confeccionado um sulco longitudinal, simulando extensões de canais ovais, posteriormente preenchidos com detritos artificiais. Após esse procedimento na outra metade foi realizada a formação de smear layer com uma vigora instrumentação da parede com movimentos de limagem. Essas amostras foram levadas ao MEV para análise prévia. Essas metades, depois de justapostas, voltaram a mufla e foram realizados os protocolos de tratamento. A análise dos dados foi realizada por meio de scores. Para a análise da dissolução e viabilidade do biofilme in situ 130 raízes foram separadas preparadas com instrumento R25 e um disco de dentina foi retirado do terço médio com uma trefina. Esses discos foram inseridos em uma placa de hawley, que foi utilizada pelo pesquisador durante três dias. Os discos foram removidos e deixados por 48 horas em BHI, em estufa a 37oC. Após a contaminação os discos voltaram para a raiz de onde foram removidos e fixados com cera utilidade voltando a mufla, sendo tratados e avaliados. Setenta discos foram utilizados para análise da dissolução e viabilidade em confocal e as imagens obtidas foram avaliadas pelo software Bioimage. Sessenta discos foram utilizados para a análise da dissolução do biofilme em MEV, sendo avaliados pré e pós-tratamento. Na comparação entre os grupos para a remoção de smear layer foram encontradas diferenças estatisticamente significantes (P < 0.05) entre os protocolos que utilizavam EDTA e Qmix, com os protocolos utilizando somente solução salina e hipoclorito seguido de solução salina independente da agitação ultrassônica. Enquanto que para a ranhura houve uma diferença estatisticamente significativa entre os grupos que utilizaram PUI e os demais grupos. Tanto a agitação ultrassônica, quanto o uso do hipoclorito de sódio como irrigante primário influenciaram significativamente para a redução do biovolume e da viabilidade bacteriana. O grupo que utilizou o NaOCl, seguido do Qmix associados ao PUI apresentou os menores valores de viabilidade e a maior dissolução do biofilme. O QMix PUI e o PAA/PUI mostraram os melhores resultados de dissolução na análise em MEV.se diferenciando estatisticamente (P<0.05) dos demais grupos. Levando-se em conta todos os critérios analisados, o protocolo que se mostrou mais eficiente foi o NaOCl seguido do QMix e associados a PUI. / The aim of this study was to evaluate the dissolution capacity and removal of biofilm formed in situ, in smear layer and debris removal and debris use ten final irrigation protocols (saline with or without ultrasonic agitation, or sodium hypochlorite as primary irrigating, and then used saline or 17% EDTA, or 2% peracetic acid (PAA), or Qmix, with or without ultrasonic agitation of both solutions). Two hundred and thirty bovine roots were sectioned and cut with 15mm in length and instrumented with Reciproc R50. For the analysis of removal of debris and smear layer were separated 100 roots, which were cleaved, and the apical third of the half of root, has a longitudinal groove made simulating extensions of oval canals, artificial subsequently filled with debris. After this procedure was performed on half the formation of smear layer with a force wall with instrumentation filing motions. These samples were taken to SEM prior to analysis. These halves, after juxtaposed, and again the flask were held treatment protocols. Data analysis was performed by means of scores. For the analysis of the dissolution and viability of the biofilm in situ roots 130 were prepared with R25 separate instrument and dentin disc was taken from the middle third with a trephine. These disks were inserted into a hawley plate, which was used by the researcher for three days. The discs were removed and left for 48 hours in BHI at 37oC. After contamination disks back to the root from which they were removed and fixed with wax utility returning to muffle being treated and evaluated. Seventy disks were used for analysis of dissolution and viability and confocal images were evaluated by Bioimage software. Sixty discs were used for the analysis of the dissolution of the biofilm SEM and are assessed before and after treatment. Comparing the groups for the removal of smear layer statistically significant differences were found (P <0.05) between the protocols used EDTA and Qmix with the protocols using only saline solution and hypochlorite followed by saline independent of ultrasonic agitation. While for the slot there was a statistically significant difference between the groups using PUI and the other groups. Both ultrasonic agitation, and the use of sodium hypochlorite as primary irrigant influenced significantly to the reduction of bacterial viability and biovolume. The group using the NaOCl, and then used Qmix associated with PUI had the lowest viability values and the highest dissolution of the biofilm. The QMix PUI and the PAA / PUI showed the best dissolution results in the analysis MEV.se differentiating statistically (P <0.05) from the other groups. Taking into account all the criteria analyzed, the protocol that was more efficient was the NaOCl and then used QMix and associated with PUI.
12

Atenuação ultrassônica devido a defeitos fora do centro KC1:Cu+ / Ultrasonic attenuation due to off-center defects: KCl:Cu+

Jordao, Jose Alberto Rodrigues 20 October 1976 (has links)
Com base em trabalhos tanto teóricos como experimentais, concluiu-se que o Cu+ fica em posição fora de centro em alguns halogenetos alcalinos. Nesse trabalho apresentamos resultados obtidos por técnicas de ultra-som, para verificar as propriedades do dipolo elástico devido a inos Cu+ em posição fora de centro em cristais de KCl. As alturas dos picos de relaxação observados em KCl: Cu+, apresentam proporcionalidade com a concentração de defeitos e a energia de ativação foi encontrada, sendo 0.1755 e V. A partir da teoria do dipolo elástico, e das concentrações de Cu+ achados por absorção ótica, determinou-se a simetria do defeito como sendo trigonal e o fator de forma |&#9551 - &#9552| = (7.7 &#177 0.8) 10-2. Usando valores teóricos para os deslocamentos dos 6 vizinhos (c1&#8254) próximos e a teoria do \"elipsóide de inclusão\", os momentos de dipolo elástico, &#9551, &#9552 e &#9553 puderam ser determinados e apresentam boa concordância com o experimento. Dada a forma do pico de atenuação, comprovou-se que a reorientação dos dipolos segue o modelo clássico com um tempo de relaxação simples &#964o &#8764-13 / With basis on theoretical and work investigation it is possible to conclude that Cu+ occupies an off-center position in several alkali halides. In this work, we report some results obtained for the elastic dipole which results form an off-senter substitutional Cu+ in KCl by ultrasonic techniques. The height of the relaxation peaks observed in KCl: Cu+ are proportional to defect concentrations, and the activation energy is 0.1755 and V. From the theory for elastic dipole, and the defect concentration measured throught optical absorption and the shape factor |&#9551 - &#9552| = (7.7 &#177 0.8) 10-2. By using theoretical values for the six nearest neighbors displacements and the \"Elipsoid inclusion theory\", the elastic dipole moments , &#9551, &#9552 e &#9553 are determined. Using the shape of the attenuation peak, we conclude that the dipole reorientation follows the classical model with a single relaxation time &#964o &#8764-13
13

Refinamento das técnicas de anestesia injetável visando garantir o bem-estar de ratos de laboratório em procedimentos experimentais / Refinement of techniques of injectable anesthesia to ensure the wellbeing of laboratory rats in experimental procedures

Laporte, Jilma Maria Aleman 24 May 2017 (has links)
Assegurar o bem-estar dos animais de laboratório e evitar a dor e o sofrimento desnecessários são as principais considerações na experimentação. Por isso, a investigação em busca de novos protocolos anestésicos que garantam um mínimo ou nulo desconforto dos animais tem-se convertido num tema prioritário. Neste estudo realizou-se a comparação do efeito da combinação de xilazina (X) e ketamina (K) com acepromazina (A) e opióides [metadona (Me), morfina (Mo) e tramadol (T)] com a finalidade de avaliar sua influência nos parâmetros fisiológicos de ratos de laboratório, para ambos os sexos, bem como seu poder analgésico e o efeito da oxigenação sobre os mesmos. A associação XKA para ratos machos e fêmeas e a associação XKMe para fêmeas foram as mais seguras e eficazes para procedimentos anestésicos. Porém, os resultados do teste de formalina com a medição da vocalização ultrassônica (VUS) sugerem que o protocolo de XKA tem um poder analgésico baixo, não sendo indicado para procedimentos que possam gerar dor moderada ou severa. Todas as associações anestésicas tiveram efeitos importantes como diurese, manutenção dos olhos abertos e hiperglicemia, os quais devem ser considerados quando possam influenciar nos resultados experimentais. Também, se conseguiu demonstrar que a oxigenação melhora a saturação de oxigênio (SO2) e os valores da pressão parcial de oxigênio (pO2) confirmando que sua utilização deveria ser sempre parte dos procedimentos experimentais com anestesia injetável para evitar a hipoxemia. Não obstante, observou-se uma acidose respiratória por aumento da pressão parcial do CO2 (pCO2) e diminuição do pH, cuja causa se relacionou à hipoventilação por depressão respiratória e acúmulo de CO2 durante o transcorrer da anestesia. Tal situação demonstra a necessidade de oxigenar os animais desde a indução da anestesia e de administrar medicamentos para reverter a depressão respiratória como a naloxona, bem como utilizar animais que não apresentem nenhum tipo de comprometimento respiratório. Portanto, a inclusão de analgesia e a oxigenação nos protocolos anestésicos injetáveis devem ser utilizadas de forma rotineira garantindo a mínima presença de dor e, com isso, resultados mais confiáveis nos procedimentos experimentais. / Ensuring the wellbeing of laboratory animals and avoiding unnecessary pain and suffering is one of the main considerations in experimentation. Therefore, the investigation of new anesthetic protocols that guarantee a minimum or null discomfort of the animals has become a priority theme. In this study, it was made an evaluation of the effect of the combination of xylazine (X) and ketamine (K) with acepromazina (A) and opioids [methadone (Me), morphine (Mo) e tramadol (T)] with the purpose of comparing their influence on the physiological parameters of laboratory rats, for both sexes, and evaluating their analgesic power and the effect of the oxygenation on them. The XKA protocol for male and females rats and the XKMe protocol for females were the safest and most effective for anesthetic procedures. However, the results of the formalin test with the measurement of the ultrasonic vocalization (VUS) suggest that the XKA protocol had a low analgesic power, and it is not indicated for procedures that can generate moderate or severe pain. All anesthetic protocols had important effects as diuresis, maintenance of open eyes, and hyperglycemia; these effects should be considered when they could influence in the experimental results. It was demonstrated that oxygenation improves oxygen saturation (SO2) and oxygen partial pressure (pO2) confirming that its use should be considered in the experimental procedures with injectable anesthesia to avoid hypoxemia. Nevertheless, a respiratory acidosis was observed due to the increase in partial pressure of CO2 (pCO2) and the decrease in pH, that could be caused for the hypoventilation due to respiratory depression and CO2 accumulation during the course of anesthesia. This leads to consider the need to pre-oxygenate animals from induction, to use drugs to reverse respiratory depression such as naloxone, and to work with animals that are not respiratory compromised. Therefore the inclusion of analgesia and oxygenation in anesthesia protocols should begin to be used routinely ensuring minimal presence of pain and thus more reliable results in the experimental procedures.
14

Refinamento das técnicas de anestesia injetável visando garantir o bem-estar de ratos de laboratório em procedimentos experimentais / Refinement of techniques of injectable anesthesia to ensure the wellbeing of laboratory rats in experimental procedures

Jilma Maria Aleman Laporte 24 May 2017 (has links)
Assegurar o bem-estar dos animais de laboratório e evitar a dor e o sofrimento desnecessários são as principais considerações na experimentação. Por isso, a investigação em busca de novos protocolos anestésicos que garantam um mínimo ou nulo desconforto dos animais tem-se convertido num tema prioritário. Neste estudo realizou-se a comparação do efeito da combinação de xilazina (X) e ketamina (K) com acepromazina (A) e opióides [metadona (Me), morfina (Mo) e tramadol (T)] com a finalidade de avaliar sua influência nos parâmetros fisiológicos de ratos de laboratório, para ambos os sexos, bem como seu poder analgésico e o efeito da oxigenação sobre os mesmos. A associação XKA para ratos machos e fêmeas e a associação XKMe para fêmeas foram as mais seguras e eficazes para procedimentos anestésicos. Porém, os resultados do teste de formalina com a medição da vocalização ultrassônica (VUS) sugerem que o protocolo de XKA tem um poder analgésico baixo, não sendo indicado para procedimentos que possam gerar dor moderada ou severa. Todas as associações anestésicas tiveram efeitos importantes como diurese, manutenção dos olhos abertos e hiperglicemia, os quais devem ser considerados quando possam influenciar nos resultados experimentais. Também, se conseguiu demonstrar que a oxigenação melhora a saturação de oxigênio (SO2) e os valores da pressão parcial de oxigênio (pO2) confirmando que sua utilização deveria ser sempre parte dos procedimentos experimentais com anestesia injetável para evitar a hipoxemia. Não obstante, observou-se uma acidose respiratória por aumento da pressão parcial do CO2 (pCO2) e diminuição do pH, cuja causa se relacionou à hipoventilação por depressão respiratória e acúmulo de CO2 durante o transcorrer da anestesia. Tal situação demonstra a necessidade de oxigenar os animais desde a indução da anestesia e de administrar medicamentos para reverter a depressão respiratória como a naloxona, bem como utilizar animais que não apresentem nenhum tipo de comprometimento respiratório. Portanto, a inclusão de analgesia e a oxigenação nos protocolos anestésicos injetáveis devem ser utilizadas de forma rotineira garantindo a mínima presença de dor e, com isso, resultados mais confiáveis nos procedimentos experimentais. / Ensuring the wellbeing of laboratory animals and avoiding unnecessary pain and suffering is one of the main considerations in experimentation. Therefore, the investigation of new anesthetic protocols that guarantee a minimum or null discomfort of the animals has become a priority theme. In this study, it was made an evaluation of the effect of the combination of xylazine (X) and ketamine (K) with acepromazina (A) and opioids [methadone (Me), morphine (Mo) e tramadol (T)] with the purpose of comparing their influence on the physiological parameters of laboratory rats, for both sexes, and evaluating their analgesic power and the effect of the oxygenation on them. The XKA protocol for male and females rats and the XKMe protocol for females were the safest and most effective for anesthetic procedures. However, the results of the formalin test with the measurement of the ultrasonic vocalization (VUS) suggest that the XKA protocol had a low analgesic power, and it is not indicated for procedures that can generate moderate or severe pain. All anesthetic protocols had important effects as diuresis, maintenance of open eyes, and hyperglycemia; these effects should be considered when they could influence in the experimental results. It was demonstrated that oxygenation improves oxygen saturation (SO2) and oxygen partial pressure (pO2) confirming that its use should be considered in the experimental procedures with injectable anesthesia to avoid hypoxemia. Nevertheless, a respiratory acidosis was observed due to the increase in partial pressure of CO2 (pCO2) and the decrease in pH, that could be caused for the hypoventilation due to respiratory depression and CO2 accumulation during the course of anesthesia. This leads to consider the need to pre-oxygenate animals from induction, to use drugs to reverse respiratory depression such as naloxone, and to work with animals that are not respiratory compromised. Therefore the inclusion of analgesia and oxygenation in anesthesia protocols should begin to be used routinely ensuring minimal presence of pain and thus more reliable results in the experimental procedures.
15

Avaliação do tecido mamário em mulheres na pós-menopausa usuárias de isoflavona da soja /

Delmanto, Armando. January 2012 (has links)
Orientador: Jorge Nahás Neto / Coorientador: Eliana Aguiar Petri Nahás / Banca: Paulo Traiman / Banca: Eduardo Carvalho Pessoa / Resumo: Avaliar o efeito da isoflavona da soja sobre o tecido mamário em mulheres na pós-menopausa. Trata-se de estudo clínico, prospectivo, randomizado, duplo-cego, placebo controlado, envolvendo 80 mulheres na pós-menopausa com sintomas vasomotores, idade entre 45 a 70 anos, acompanhadas no Ambulatório de Climatério e Menopausa da Faculdade de Medicina de Botucatu-Unesp, de janeiro de 2005 a dezembro de 2006. Na randomização, 40 pacientes receberam 100 mg isoflavona da soja/dia (duas cápsulas de 125 mg de extrato seco de glicine Max) e 40 pacientes placebo (duas cápsulas de lactose) durante 10 meses. A densidade mamária (DM) foi avaliada pela mamografia e o parênquima mamário pela ultrassonografia de mamas no início e após dez meses de seguimento. Para análise estatística foram utilizados o teste t-Student, ANOVA, teste de Mann-Whitney e teste do Qui-Quadrado. Na comparação das características clínicas iniciais entre os grupos de usuárias de isoflavona e placebo, não houve diferenças significantes, com valores médios de idade de 55,1±6,0 e 56,2±7,7 anos, tempo de menopausa de 6,6±4,8 e 7,1±4,2 anos e IMC de 29,7±5,0 e 28,5±4,9 kg/m2, respectivamente (p>0,05). Concluíram o estudo 32 pacientes sob isoflavona e 34 sob placebo. Na comparação da densidade mamográfica entre os momentos inicial e final, não houve diferença estatisticamente significativa. Na avaliação do parênquima mamário pela ultrassonografia, não houve diferença entre os grupos. Na comparação entre os momentos dentro de cada grupo, não foram constatadas diferenças significativas nos parâmetros da mamografia e ultrassonografia. No período de 10 meses, o uso de isoflavona de soja não modificou o tecido mamário, avaliado pela mamografia e ultrassonografia, em mulheres na pós-menopausa / Abstract: To evaluate the effect of soy isoflavone on breast tissue in postmenopausal women. This study is a prospective, randomized, double-blind, placebo-controlled trial involving 80 postmenopausal women with vasomotor symptoms, aged 45-70 years, followed in Climacteric and Menopause Clinic of the Botucatu Medical School-UNESP, from January 2005 to December 2006. At randomization, 40 patients received 100 mg of soy isoflavone/day (two capsules of 125 mg standardized soy extract, Glicine max) and 40 patients, placebo (two capsules of lactose) for 10 months. The breast density was evaluated by mammography and breast parenchyma by ultrasound, at baseline and after ten months of follow-up. The Student t-test, ANOVA, Mann-Whitney and Chi-Square were used in the statistical analysis. In comparison of baseline clinical characteristics between the isoflavone and placebo groups, there were no significant differences, with mean age of 55.1 ± 6.0 and 56.2 ± 7.7 years, duration of menopause 6.6 ± 4.8 and 7.1 ± 4.2 years and BMI 29.7 ± 5.0 and 28.5 ± 4.9 kg/m2, respectively (p> 0.05). Concluded the study, 32 patients on isoflavone and 34 in the placebo group. In comparison in mammographic density (MD) between moments, baseline and final, there was no difference statistically significant. In the evaluation of breast parenchyma by ultrasound, there was no difference between groups. In comparing the moments within each group, there were no significant differences in the parameters of mammography and ultrasound. In 10 months, the use of soy isoflavone did not affect breast tissue, as assessed by mammography and ultrasound, in postmenopausal women / Doutor
16

Avaliação dos efeitos da irrigação ultrassônica passiva, por meio de microtomografia computadorizada, microscopia óptica e microscopia eletrônica de varredura / Evaluation of the effect of passive ultrasonic irrigation using computed microtomography, optical microscopy and scanning electron microscopy

Samuel Henrique Camara de Bem 09 May 2016 (has links)
O presente trabalho teve como objetivo determinar, por meio de microtomografia computadorizada (&mu;CT), o aumento de volume interno, após realização da irrigação ultrassônica passiva (P.U.I.), em diferentes substratos (dentes humanos e bovinos); a remoção da camada de &ldquo;smear&rdquo; e &ldquo;debris&rdquo; do canal radicular, após a realização da P.U.I., com diferentes soluções irrigadoras finais, por meio de microscopia eletrônica de varredura (MEV) e microscopia óptica (MO). Para a verificação do aumento de volume interno vinte dentes (dez humanos e dez bovinos) foram selecionados e padronizados em 17 mm ± 1 mm de comprimento. Os dentes humanos foram preparados até o diâmetro final # 50/05, os dentes bovinos por possuírem canais amplos não receberam preparo biomecânico. Cada dente foi fixado na base da mesa giratória do aparelho de &mu;CT e realizou-se o primeiro exame &mu;CT. Os espécimes foram então submetidos a P.U.I. (aparelho EMS em frequência de 32 KHz) e em seguida foi realizado o segundo exame de &mu;CT respeitando os mesmos padrões do primeiro exame. As imagens capturadas foram comparadas antes e depois da P.U.I. Para a verificação, da remoção da camada de &ldquo;smear&rdquo; e &ldquo;debris&rdquo;, foram selecionados 46 caninos inferiores. Os dentes foram preparados até o diâmetro final # 50/05 e submetidos a P.U.I. com diferentes soluções irrigadoras finais: G3 (Soro fisiológico); G4 (NaOCl 1 %); G5 (EDTA-C 17 %); G6 (NaOCl 1 % / EDTA-C 17 %). Após a P.U.I. vinte e quatro dentes foram preparados e analisados em MEV e vinte e dois dentes foram submetidos ao processamento histológico e analisados em MO. A presença da camada de &ldquo;smear&rdquo; foi determinada a partir da atribuição de escores que variaram de 1 - 4. A presença de &ldquo;debris&rdquo; foi determinada a partir da grade de integração do software Image J. Os dados obtidos foram analisados com auxílio do software BioEstat 5.0. Os resultados mostraram que a P.U.I. aumentou significativamente o volume interno do canal radicular nos dentes humanos (p=0,008) e bovinos (p=0,002). A P.U.I. não removeu a camada de &ldquo;smear&rdquo;; e não removeu &ldquo;debris&rdquo; (p=0,1923) de forma estatisticamente significativa. Concluiu-se que a P.U.I. não é passiva, ela promove alteração de volume no canal radicular, aumentando seu volume interno independentemente do substrato testado; não removeu a camada de &ldquo;smear&rdquo;, mas reduziu significativamente o tempo necessário para que a solução quelante final agisse; não promoveu a remoção de &ldquo;debris&rdquo; estatisticamente significativa, mas independentemente da solução irrigadora final, realizar a P.U.I. aumenta qualitativamente a remoção de &ldquo;debris&rdquo; do canal radicular. / The aim of this study was to determine by &mu;CT the internal volume increasing, after using of P.U.I., in different dental substrates (human and bovine); the removal of the smear layer and debris from the root canal, after using P.U.I. with different irrigation solutions, using SEM e OM. In order to verify the internal volume increasing, 20 teeth (ten humans and ten bovine) were selected and standardized with 17 mm ± 1 mm of length. Human teeth were prepared to a final diameter of #50/05. As the bovine teeth presents large root canal, they did not receive biomechanical preparation. Each tooth was fixed on a movable platform on the &mu;CT device and the first test was carried out. The specimens were subjected to P.U.I. (EMS device with 32 KHz of frequency) in order to performed the second &mu;CT test respecting the same standards. Images were captured and compared before and after P.U.I. Fourth six mandibular canine teeth were selected to verify the smear layer and debris removal. The teeth were prepared to the final diameter of #50/05 and subjected to P.U.I. with different irrigation solutions: G3 (Saline); G4 (NaOCl 1 %); G5 (EDTA-C 17 %); G6 (NaOCl 1% / EDTA-C 17 %). After P.U.I. 24 teeth were prepared and analyzed using SEM and 22 teeth were subjected to histological processing and thus analyzed with OM. The present smear layer was determined by score s\' attribution ranging from 1 - 4. Presence of debris was determined by attribution of the screen integration from the Image J software. Data were analyzed with the support of BioEstat 5.0 software. The results showed that P.U.I. significantly increased the internal volume of root canal of human (p=0,008) and bovine teeth (p=0,002). The P.U.I. did not remove the smear layer nor debris (p=0,1923) statistically significant. It was concluded that P.U.I. is not passive, it increases the internal volume of root canal independently of the tested dental substrates; it did not remove the smear layer, but significantly decreased the onset of action of the final solution; it did not promote statistically significant differences regarding the debris removal however independently of the final irrigation solution to carry out P.U.I. increases the root canal debris removal.
17

Avaliação do tecido mamário em mulheres na pós-menopausa usuárias de isoflavona da soja

Delmanto, Armando [UNESP] 30 July 2012 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:39Z (GMT). No. of bitstreams: 0 Previous issue date: 2012-07-30Bitstream added on 2014-06-13T18:47:00Z : No. of bitstreams: 1 delmanto_a_dr_botfm.pdf: 571026 bytes, checksum: 2efa82a630b3a102bd0c2beed1370eec (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Avaliar o efeito da isoflavona da soja sobre o tecido mamário em mulheres na pós-menopausa. Trata-se de estudo clínico, prospectivo, randomizado, duplo-cego, placebo controlado, envolvendo 80 mulheres na pós-menopausa com sintomas vasomotores, idade entre 45 a 70 anos, acompanhadas no Ambulatório de Climatério e Menopausa da Faculdade de Medicina de Botucatu-Unesp, de janeiro de 2005 a dezembro de 2006. Na randomização, 40 pacientes receberam 100 mg isoflavona da soja/dia (duas cápsulas de 125 mg de extrato seco de glicine Max) e 40 pacientes placebo (duas cápsulas de lactose) durante 10 meses. A densidade mamária (DM) foi avaliada pela mamografia e o parênquima mamário pela ultrassonografia de mamas no início e após dez meses de seguimento. Para análise estatística foram utilizados o teste t-Student, ANOVA, teste de Mann-Whitney e teste do Qui-Quadrado. Na comparação das características clínicas iniciais entre os grupos de usuárias de isoflavona e placebo, não houve diferenças significantes, com valores médios de idade de 55,1±6,0 e 56,2±7,7 anos, tempo de menopausa de 6,6±4,8 e 7,1±4,2 anos e IMC de 29,7±5,0 e 28,5±4,9 kg/m2, respectivamente (p>0,05). Concluíram o estudo 32 pacientes sob isoflavona e 34 sob placebo. Na comparação da densidade mamográfica entre os momentos inicial e final, não houve diferença estatisticamente significativa. Na avaliação do parênquima mamário pela ultrassonografia, não houve diferença entre os grupos. Na comparação entre os momentos dentro de cada grupo, não foram constatadas diferenças significativas nos parâmetros da mamografia e ultrassonografia. No período de 10 meses, o uso de isoflavona de soja não modificou o tecido mamário, avaliado pela mamografia e ultrassonografia, em mulheres na pós-menopausa / To evaluate the effect of soy isoflavone on breast tissue in postmenopausal women. This study is a prospective, randomized, double-blind, placebo-controlled trial involving 80 postmenopausal women with vasomotor symptoms, aged 45-70 years, followed in Climacteric and Menopause Clinic of the Botucatu Medical School-UNESP, from January 2005 to December 2006. At randomization, 40 patients received 100 mg of soy isoflavone/day (two capsules of 125 mg standardized soy extract, Glicine max) and 40 patients, placebo (two capsules of lactose) for 10 months. The breast density was evaluated by mammography and breast parenchyma by ultrasound, at baseline and after ten months of follow-up. The Student t-test, ANOVA, Mann-Whitney and Chi-Square were used in the statistical analysis. In comparison of baseline clinical characteristics between the isoflavone and placebo groups, there were no significant differences, with mean age of 55.1 ± 6.0 and 56.2 ± 7.7 years, duration of menopause 6.6 ± 4.8 and 7.1 ± 4.2 years and BMI 29.7 ± 5.0 and 28.5 ± 4.9 kg/m2, respectively (p> 0.05). Concluded the study, 32 patients on isoflavone and 34 in the placebo group. In comparison in mammographic density (MD) between moments, baseline and final, there was no difference statistically significant. In the evaluation of breast parenchyma by ultrasound, there was no difference between groups. In comparing the moments within each group, there were no significant differences in the parameters of mammography and ultrasound. In 10 months, the use of soy isoflavone did not affect breast tissue, as assessed by mammography and ultrasound, in postmenopausal women
18

Atenuação ultrassônica devido a defeitos fora do centro KC1:Cu+ / Ultrasonic attenuation due to off-center defects: KCl:Cu+

Jose Alberto Rodrigues Jordao 20 October 1976 (has links)
Com base em trabalhos tanto teóricos como experimentais, concluiu-se que o Cu+ fica em posição fora de centro em alguns halogenetos alcalinos. Nesse trabalho apresentamos resultados obtidos por técnicas de ultra-som, para verificar as propriedades do dipolo elástico devido a inos Cu+ em posição fora de centro em cristais de KCl. As alturas dos picos de relaxação observados em KCl: Cu+, apresentam proporcionalidade com a concentração de defeitos e a energia de ativação foi encontrada, sendo 0.1755 e V. A partir da teoria do dipolo elástico, e das concentrações de Cu+ achados por absorção ótica, determinou-se a simetria do defeito como sendo trigonal e o fator de forma |&#9551 - &#9552| = (7.7 &#177 0.8) 10-2. Usando valores teóricos para os deslocamentos dos 6 vizinhos (c1&#8254) próximos e a teoria do \"elipsóide de inclusão\", os momentos de dipolo elástico, &#9551, &#9552 e &#9553 puderam ser determinados e apresentam boa concordância com o experimento. Dada a forma do pico de atenuação, comprovou-se que a reorientação dos dipolos segue o modelo clássico com um tempo de relaxação simples &#964o &#8764-13 / With basis on theoretical and work investigation it is possible to conclude that Cu+ occupies an off-center position in several alkali halides. In this work, we report some results obtained for the elastic dipole which results form an off-senter substitutional Cu+ in KCl by ultrasonic techniques. The height of the relaxation peaks observed in KCl: Cu+ are proportional to defect concentrations, and the activation energy is 0.1755 and V. From the theory for elastic dipole, and the defect concentration measured throught optical absorption and the shape factor |&#9551 - &#9552| = (7.7 &#177 0.8) 10-2. By using theoretical values for the six nearest neighbors displacements and the \"Elipsoid inclusion theory\", the elastic dipole moments , &#9551, &#9552 e &#9553 are determined. Using the shape of the attenuation peak, we conclude that the dipole reorientation follows the classical model with a single relaxation time &#964o &#8764-13
19

Avaliação da efetividade de diferentes protocolos de irrigação na limpeza do canal radicular / Evaluation of the effectiveness of different irrigation protocols in the root canal cleaning

Samuel Lucas Fernandes 15 June 2015 (has links)
O objetivo desse estudo foi avaliar a capacidade de dissolução e remoção de biofilme formado in situ, na remoção de smear layer e debris empregando dez protocolos de irrigação final (solução fisiológica com ou sem agitação ultrassônica; ou hipoclorito de sódio como irrigante primário, seguido de solução salina, ou EDTA 17%, ou ácido peracético (PAA) 2%, ou Qmix, com ou sem agitação ultrassônica de ambas as soluções). Duzentos e trinta raízes bovinas foram seccionadas e cortadas com 15mm de comprimento e instrumentadas com o instrumento Reciproc R50. Para a análise da remoção de debris e smear layer foram separadas 100 raízes, que foram clivadas e, no terço apical de uma das metades radiculares, foi confeccionado um sulco longitudinal, simulando extensões de canais ovais, posteriormente preenchidos com detritos artificiais. Após esse procedimento na outra metade foi realizada a formação de smear layer com uma vigora instrumentação da parede com movimentos de limagem. Essas amostras foram levadas ao MEV para análise prévia. Essas metades, depois de justapostas, voltaram a mufla e foram realizados os protocolos de tratamento. A análise dos dados foi realizada por meio de scores. Para a análise da dissolução e viabilidade do biofilme in situ 130 raízes foram separadas preparadas com instrumento R25 e um disco de dentina foi retirado do terço médio com uma trefina. Esses discos foram inseridos em uma placa de hawley, que foi utilizada pelo pesquisador durante três dias. Os discos foram removidos e deixados por 48 horas em BHI, em estufa a 37oC. Após a contaminação os discos voltaram para a raiz de onde foram removidos e fixados com cera utilidade voltando a mufla, sendo tratados e avaliados. Setenta discos foram utilizados para análise da dissolução e viabilidade em confocal e as imagens obtidas foram avaliadas pelo software Bioimage. Sessenta discos foram utilizados para a análise da dissolução do biofilme em MEV, sendo avaliados pré e pós-tratamento. Na comparação entre os grupos para a remoção de smear layer foram encontradas diferenças estatisticamente significantes (P < 0.05) entre os protocolos que utilizavam EDTA e Qmix, com os protocolos utilizando somente solução salina e hipoclorito seguido de solução salina independente da agitação ultrassônica. Enquanto que para a ranhura houve uma diferença estatisticamente significativa entre os grupos que utilizaram PUI e os demais grupos. Tanto a agitação ultrassônica, quanto o uso do hipoclorito de sódio como irrigante primário influenciaram significativamente para a redução do biovolume e da viabilidade bacteriana. O grupo que utilizou o NaOCl, seguido do Qmix associados ao PUI apresentou os menores valores de viabilidade e a maior dissolução do biofilme. O QMix PUI e o PAA/PUI mostraram os melhores resultados de dissolução na análise em MEV.se diferenciando estatisticamente (P<0.05) dos demais grupos. Levando-se em conta todos os critérios analisados, o protocolo que se mostrou mais eficiente foi o NaOCl seguido do QMix e associados a PUI. / The aim of this study was to evaluate the dissolution capacity and removal of biofilm formed in situ, in smear layer and debris removal and debris use ten final irrigation protocols (saline with or without ultrasonic agitation, or sodium hypochlorite as primary irrigating, and then used saline or 17% EDTA, or 2% peracetic acid (PAA), or Qmix, with or without ultrasonic agitation of both solutions). Two hundred and thirty bovine roots were sectioned and cut with 15mm in length and instrumented with Reciproc R50. For the analysis of removal of debris and smear layer were separated 100 roots, which were cleaved, and the apical third of the half of root, has a longitudinal groove made simulating extensions of oval canals, artificial subsequently filled with debris. After this procedure was performed on half the formation of smear layer with a force wall with instrumentation filing motions. These samples were taken to SEM prior to analysis. These halves, after juxtaposed, and again the flask were held treatment protocols. Data analysis was performed by means of scores. For the analysis of the dissolution and viability of the biofilm in situ roots 130 were prepared with R25 separate instrument and dentin disc was taken from the middle third with a trephine. These disks were inserted into a hawley plate, which was used by the researcher for three days. The discs were removed and left for 48 hours in BHI at 37oC. After contamination disks back to the root from which they were removed and fixed with wax utility returning to muffle being treated and evaluated. Seventy disks were used for analysis of dissolution and viability and confocal images were evaluated by Bioimage software. Sixty discs were used for the analysis of the dissolution of the biofilm SEM and are assessed before and after treatment. Comparing the groups for the removal of smear layer statistically significant differences were found (P <0.05) between the protocols used EDTA and Qmix with the protocols using only saline solution and hypochlorite followed by saline independent of ultrasonic agitation. While for the slot there was a statistically significant difference between the groups using PUI and the other groups. Both ultrasonic agitation, and the use of sodium hypochlorite as primary irrigant influenced significantly to the reduction of bacterial viability and biovolume. The group using the NaOCl, and then used Qmix associated with PUI had the lowest viability values and the highest dissolution of the biofilm. The QMix PUI and the PAA / PUI showed the best dissolution results in the analysis MEV.se differentiating statistically (P <0.05) from the other groups. Taking into account all the criteria analyzed, the protocol that was more efficient was the NaOCl and then used QMix and associated with PUI.
20

Avaliação da eficiência de pontas de ultrassom usada e adaptada na remoção de retentores metálicos

Figueira, Keylla Lopes, 92-99211-2267 27 July 2018 (has links)
Submitted by Divisão de Documentação/BC Biblioteca Central (ddbc@ufam.edu.br) on 2018-09-13T13:11:58Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) dissertação final.pdf: 1572687 bytes, checksum: 674c29e0d0506fb0bcb429ddc3a7ef32 (MD5) / Made available in DSpace on 2018-09-13T13:11:58Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) dissertação final.pdf: 1572687 bytes, checksum: 674c29e0d0506fb0bcb429ddc3a7ef32 (MD5) Previous issue date: 2018-07-27 / FAPEAM - Fundação de Amparo à Pesquisa do Estado do Amazonas / This study evaluated in vitro the efficiency of used and adapted ultrasonic tips in the removal of metal retainers. Methods: Forty maxillary canines received Ni-Cr alloy fused metal retainers fixed with zinc phosphate cement. Group I - without ultrasonic vibration, Group II - with ultrasonic vibration using the ST – 09 new tip, Group III - with the ST - 09 used tip (used in 10 previous procedures) and Group IV - with ST – 09 adapted tip fitted with stone mounted. Groups II, III and IV received ultrasonic vibration for one minute with ENAC (Osada Eletric Co., Tokyo, Japan) at maximum frequency. The tensile test was performed on all specimens in the Universal Testing Machine with a speed of 1 mm/min, obtaining values in Newton, the data statistically analyzed using ANOVA and Tukey Test (p <0.05). RESULTS: The results showed statistically significant differences between the groups tested (control group = 472,641 N, new tip = 213,329 N, used tip = 408,185 N and adapted tip = 348,292 N). The lowest mean tensile strength was found in the group where the ultrasonic vibration was applied with the new tip followed by the adapted tip. The results show that the new tip reduces the tensile force required to remove the post cast. Conclusion: The change of the metallic structure of the ultrasonic tip interferes in the ultrasonic efficiency. / Este trabalho comparou in vitro a eficiência de pontas de ultrassom usada e adaptada na remoção de retentores metálicos fundidos. Métodos: Quarenta caninos superiores receberam retentores metálicos fundidos em liga Ni-Cr fixados com cimento de fosfato de zinco. Foram alocados em 4 grupos: Grupo I - sem vibração ultrassônica, Grupo II - com vibração ultrassônica utilizando a ponta ST - 09 nova, Grupo III - com a ponta ST - 09 usada (utilizada em 10 procedimentos anteriores) e Grupo IV - com a ponta ST – 09 adaptada com pedra montada. Os grupos II, III e IV receberam vibração ultrassônica por um minuto com aparelho ENAC (Osada Eletric Co., Tokyo, Japão) em máxima frequência (30 kHz). O teste de tração foi realizado em todos os espécimes na Máquina Universal de Ensaio com velocidade de 1 mm/min obtendo valores em Newton, os valores foram submetidos à análise estatística Anova e Teste Tukey (p<0.05). Resultados: Os resultados mostraram diferenças estatisticamente significantes entre os grupos testados (grupo controle = 472.641 N, ponta nova = 213.329 N, ponta usada = 408.185 N e ponta adaptada = 348.292 N). A menor média de força de tração foi encontrada no grupo que a vibração ultrassônica foi aplicada com a ponta nova, seguida da ponta adaptada. Os resultados evidenciaram que a ponta nova reduz a força de tração necessária para remoção dos retentores metálicos fundidos. Conclusão: A alteração da estrutura metálica da ponta ultrassônica interfere na eficiência ultrassônica.

Page generated in 0.0416 seconds