• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 45
  • 12
  • 5
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 68
  • 47
  • 32
  • 29
  • 22
  • 22
  • 20
  • 19
  • 18
  • 17
  • 16
  • 15
  • 13
  • 13
  • 12
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
51

Efeito da velocidade ascensional na produção de hidrogênio em reator anaeróbio de leito fluidizado

Reis, Cristiane Marques dos 30 August 2010 (has links)
Made available in DSpace on 2016-06-02T19:56:41Z (GMT). No. of bitstreams: 1 3335.pdf: 2600508 bytes, checksum: 7bd7dedf1baa69c50930a1552ca3cb12 (MD5) Previous issue date: 2010-08-30 / Financiadora de Estudos e Projetos / This study evaluated the influence of the upflow velocity in anaerobic fluidized bed reactor to produce hydrogen. In order to compare that effect, four reactors were used under different upflow velocities each: 0.30; 0.60; 1.24 and 1.88 cm.s-1. Expanded clay was used as support material for immobilization. A synthetic wastewater containing glucose (5000 mg.L-1) was used as substrate. Reactor R124 that was operated under minimum fluidization velocity (1.24 cm.s-1) showed the best values for hydrogen production. The maximum hydrogen production rate was found to be 1.22 L.h-1.L-1. The maximum hydrogen yield was 2.55 mol H2 mol-1 glucose and the biogas content ranged between 30,5 and 61,8 %. No methane was generated. The optimum TDH for expanded bed reactors was 1h while in fluidized bed reactors were 2h. Ethanol was the main metabolite produced, suggesting an ethanol-type fermentation. No trends were shown regardless of the upflow velocity imposed to the system. However, the higher the velocity applied, the higher the hydrogen production rate. / Neste trabalho foi analisada a influência da velocidade ascensional em reator anaeróbio de leito fluidizado para a produção de hidrogênio. A fim de comparação foram empregados quatro reatores apresentando diferentes valores de velocidade de ascensão do fluido, a saber: 0,30 (R030); 0,60 (R060); 1,24 (R124) e 1,88 cm.s-1 (R188). Como material suporte de imobilização foi utilizada a argila expandida. Uma água residuária sintética contendo glicose (5000 mg.L-1) foi utilizada como substrato. O reator R124 trabalhando na velocidade de mínima fluidização foi o reator que apresentou as melhores condições para a produção de hidrogênio. O valor máximo de produção volumétrica de hidrogênio foi de 1,22 L.h-1.L-1. O rendimento foi de 2,55 mol H2 .mol-1 glicose e o conteúdo no biogás entre 30,5 e 61,8 %. Não houve produção de metano em nenhum dos reatores empregados. O TDH ótimo observado para os reatores expandidos foi em 1h enquanto que nos reatores fluidizados o TDH ótimo foi de 2h. Etanol foi o principal metabólito produzido, sugerindo que a rota etanólica de produção foi predominante. Em relação à velocidade ascensional aplicada não foi observada relação com o rendimento nem com o conteúdo do biogás. Porém, quanto maior a velocidade ascensional aplicada, maior a produção volumétrica de H2.
52

Avaliação do desempenho de um reator anaeróbio compartimentado no tratamento de esgoto doméstico /

Sato, Cibele Midori. January 2013 (has links)
Orientador: Tsunao Matsumoto / Banca: Liliane Lazzari Alberti / Banca: Marc Arpad Boncz / Resumo: A aplicação de reatores UASB (Upflow Anaerobic Sludge Blanket) passou a ocupar uma posição de destaque, principalmente no Brasil, face às condições ambientais de temperatura favoráveis, baixo custo, simplicidade operacional e baixa produção de sólidos. Com o intuito de aprimorá-lo, este estudo aliou as características construtivas e operacionais destes reatores com as dos Reatores Anaeróbios Compartimentados (RAC), caracterizados por oferecerem a possibilidade de separação das fases que ocorrem na digestão anaeróbia e o aumento do tempo de contato entre a biomassa e o efluente. Assim, foi projetado e construído um reator vertical, contendo dois tubos concêntricos em seu interior, visando à separação das etapas acidogênica e metanogênica, a partir da cinética de crescimento dos microrganismos presentes. A pesquisa teve como objetivo principal estudar o comportamento e avaliar o desempenho do reator UASB compartimentado sob nova configuração, no período de partida e operação, tratando esgoto doméstico. O monitoramento do sistema foi dividido em duas etapas: partida e operação. Durante a partida, os valores de pH e alcalinidade mantiveram-se estáveis dentro de uma faixa adequada. Os resultados apresentados durante seu monitoramente indicaram ainda, que o inóculo utilizado promoveu condições adequadas para a partida do reator, com remoção média de DQO de 53,8%, chegando a atingir 82,8% ao final desta etapa. Na segunda etapa de monitoramento, ocorreram diversos problemas relacionados à operação do sistema, ocasionando sua paralisação durante alguns dias. Os valores de pH encontraram-se dentro da faixa adequada, contudo, a alcalinidade sofreu variações quando houve interrupção no sistema. A remoção de matéria orgânica apresentou-se estável, mesmo após tais interrupções, com eficiência média de remoção de 80% para a DQO e 78% para a DBO. Além disso, ambas chegaram a alcançar 90% na ... / Abstract: Application of UASB (Upflow Anaerobic Sludge Blanket) reactor has come to occupy a prominent position, especially in Brazil, due to favorable climatic conditions, low cost, operational simplicity and low production solids. In order to improve it, this study combined constructional and operational features of these reactors with the Compartmented Anaerobic Reactor (CAR), characterized by offering the possibility of phase separation occurring in the anaerobic digestion and increase the contact time between the biomass and effluent. Thus a vertical reactor was designed and constructed containing two concentric tubes inside, in order to separate the acidogenic and methanogenic steps from the kinetics of growth of microrganisms present. The research aimed to study the behavior and evaluate the performance of the UASB compartmentalized reactor under new configuration during starting and operation, treating domestic wastewater. The monitoring system was divided into two stages: starting and operating. During the start-up, the values of pH and alkalinity remained stable within a proper range. The results presented during its monitoring also indicated that the inoculum used promoted conditions for starting the reactor, with average COD removal of 53,8%, reaching 82,8% at the end of this step. In the second stage of monitoring, there were several problems related to system operation, causing a stoppage for a few days. The pH values were within the appropriate range, however, the alkalinity variations experienced when there was an interruption in the system. The removal of organic matter remained stable even after such interruption, with average removal efficiency of 80% to 78% for COD and BOD. Moreover, both even reached 90% removal efficiency / Mestre
53

Produção de hidrogênio em reator anaeróbio de leito fixo e fluxo ascendente a partir de água residuária de indústria de refrigerantes / Hydrogen production by an upflow anaerobic packed-bed reactor using soft-drink wastewater

Guilherme Peixoto 28 April 2008 (has links)
Este trabalho teve como objetivo a produção de hidrogênio em reator anaeróbio de leito fixo com fluxo ascendente utilizando-se efluente de indústria de refrigerantes. Os resultados obtidos demonstraram que a água residuária semi-sintética simulando efluente de indústria de refrigerantes tem um bom potencial de geração de hidrogênio. Dados da operação dos dois reatores utilizados mostraram que o maior rendimento foi alcançado pelo reator operado sem a adição de meio contendo nutrientes (R2), pois este foi capaz de atingir 4,2 mol \'H IND.2\'/mol de substrato em contraste com 2,5 mol \'H IND.2\'/mol de substrato, obtida pelo reator (R1), cujo afluente continha suplementação nutricional. Constatou-se que o reator operado sem adição de nutrientes (R2) apresentou continuidade na produção de hidrogênio, fato que não ocorreu com o reator R1, que exibiu uma produção efêmera e significativamente inferior. O melhor desempenho na velocidade de produção de hidrogênio e porcentagem do mesmo na composição do biogás também foi observado para o reator R2, que atingiu 0,52 L/h.L e 18,9% de \'H IND.2\' contra 0,28 L/h.L e 2,1% de \'H IND.2\' obtidos pelo reator com suplementação nutricional (R1). Após esta primeira etapa comparativa em que os reatores foram operados simultaneamente com TDH teórico de 0,5 h, prosseguiu-se apenas com a operação do reator R2, porém com tempo de detenção hidráulica teórico de 1 h, o que induziu uma maior conversão do substrato a ácidos e álcoois, mudou as características hidrodinâmicas do leito e afetou negativamente a produção de hidrogênio. / This work was aimed on hydrogen production in an upflow anaerobic packed-bed reactor fed with soft-drink wastewater. The results obtained show that the semisynthetic soft-drink wastewater has a good hydrogen generation potential. Data obtained from the operation of both reactors indicated that the reactor operated without the addition of medium containing macro and micronutrients (R2) provided higher hydrogen yield (4,2 mol \'H IND.2\'/mol of substrate) as compared to the reactor (R1) operated with the addition of nutrient medium, which achieved lower hydrogen production yield (2,5 mol \'H IND.2\'/mol of substrate). It was observed that the reactor operated without the addition of nutrients (R2) showed continuous hydrogen production, while the reactor R1 exhibited a short period of production and lower amounts of hydrogen. Better hydrogen production rate and percentage in the biogas were also observed for the reactor R2, which achieved 0,52 L/h.L and 18,9% of \'H IND.2\' against 0,28 L/h.L and 2,1% of \'H IND.2\' obtained by the reactor with nutrient addition (R1). After operation with HDT of 0,5 h, the reactor R2 was operated with theoretical HDT of 1 h. Under this condition, the substrate was mainly converted to acids and solvents, negatively affecting the hydrogen production and the hydrodynamic pattern of the reactor.
54

Avaliação da dupla filtração para tratamento de água superficial utilizando filtração ascendente em areia grossa / Evaluation of double filtration systems for treatment of surface water using direct upflow filtration in coarse sand

Donizeti de Paula 08 August 2003 (has links)
Este trabalho consiste na avaliação do desempenho de uma instalação piloto de dupla filtração no tratamento de água superficial, apresentando turbidez entre 8,5 e 21 uT. A instalação piloto constituída de um sistema de filtração de duas fases, com filtração direta ascendente em areia grossa seguida da filtração rápida descendente em areia fina. A taxa de filtração variou de 120 a 360 m3/m2.dia no filtro ascendente e de 200 a 400 m3/m2.dia no filtro ascendente. Foram executadas descargas de fundo intermediários no filtro ascendente durante a carreira de filtração para avaliar a instalação piloto. Além disso, simulou pico de turbidez, para avaliar as condições. Baseado no trabalho experimental concluiu-se que: (i) a eficiência global do sistema de dupla filtração ascendente em areia grossa foi satisfatória, apresentando efluente final com turbidez inferior a 1 uT e cor verdadeira inferior a 1 uH; (ii) a distribuição da perda de carga nas camadas do meio granular do FAAG não apresentou diferenças significativas para as variadas taxas de filtração e modo de operação (com e sem execução de DIFs); (iii) os ensaios que foram realizados com a execução de DIFs apresentaram carreiras de filtração mais longas. / This work concerns the study of the performance of a double filtration pilot plant whom treating surface water, presenting turbidity between 8,5 and 21,0 NTU. The pilot plant consisted of a two-stage filtration system, with an upflow coarse sand direct filtrer followed by a dowflow fine sand filter. Filtration rats varied from 120 to 360 m/day in the upflow filter and from 200 to 400 m/day in the downflow filter. Intermediate downflow in the upflow filter were performed during the run length do evaluate the performance of the pilot plant in addition, a peak of turbidity in the for influent selected filter operating varabile, was studied here in. Based on the experimental work carried out, it was concluded that: (i) the global efficiency of the system of double filtration with upflow filtration in coarse sand was satisfactory, presenting final efflents with inferior turbidity to 1,0 NTU and inferior true color to 1 uH; (ii) the distribution of the load loss in the layers of the granular middle of FAAG didn\'t present significant differences for the varied filtration taxes and operation way (with and without execution of DFIs); (iii) the rehearsals that were accomplished with the execution of DFIs presented longer filtration runs.
55

Estudo do desempenho de reator anaeróbio-aeróbio de escoamento ascendente no tratamento de esgoto sanitário com espuma de poliuretano como suporte de imobilização da biomassa / Study on the performance of an anaerobic-aerobic upflow reactor in the treatment of wastewater using polyurethane foam as a support for biomass immobilization

Sergio Brasil Abreu 27 June 2003 (has links)
O projeto consistiu na concepção e avaliação do desempenho de um sistema anaeróbio-aeróbio para tratamento de esgoto sanitário. O leito do reator foi dividido em quatro compartimentos de igual volume. Foi usada espuma de poliuretano para imobilização da biomassa e, para facilitar a partida do reator, esse material suporte foi previamente inoculado. O projeto teve três fases distintas: na primeira etapa, foi observada a importância da concentração de biomassa anaeróbia no desempenho de reator anaeróbio a princípio operado com metade do leito reacional com espuma e, a seguir, com o leito todo preenchido com espuma. Na segunda etapa, foram testados diferentes tempos de detenção hidráulica no reator que operou apenas em condições anaeróbias. Na última etapa foi operado o reator combinado anaeróbio-aeróbio. Ficou constatada a importância da concentração de microrganismos no desempenho do reator anaeróbio, pois com o aumento da quantidade de espuma, o reator atingiu resultados melhores e maior estabilidade operacional. Foi comprovada a influência do tempo de detenção hidráulica (TDH) no desempenho do reator. Tempos de detenção muito altos acarretam problemas de transferência de massa líquido-sólido, e baixos TDH dificultam adequada ação dos microrganismos. O melhor resultado para o reator em operação exclusivamente anaeróbia foi para o TDH de 10 horas, no qual se conseguiu reduzir a DQO de amostra bruta de 389 +/- 70 mg/L para 137 +/- 16 mg/L, em média. Para o reator operado anaeróbio-aeróbio a DQO de amostra bruta decresceu de 259 +/- 69 mg/L para 93 +/- 31 mg/L, em média. A comparação de todos os resultados obtidos, evidenciou a importância do pós-tratamento aeróbio na remoção de parcela de matéria orgânica não removida em tratamento unicamente anaeróbio. / The project consisted in the design and performance evaluation of an anaerobic-aerobic system for wastewater treatment. Polyurethane foam was used for biomass immobilization and, to smooth the reactor start-up, this supporting material was previously inoculated. The project was divided in three distinct phases. In the first one, the importance of the anaerobic biomass concentration was observed in the performance of the anaerobic reactor in a way to operate the reactor primarily with half of the reaction bed filled with foam and subsequently operate it with the bed completely filled with foam. In the second phase, different times of hydraulic retention were tested with the reactor operating exclusively in anerobic conditions. In the third and last phase, an anaerobic-aerobic combined reactor was operated. It was possible to confirm the importance of microorganism concentration in the performance of the anaerobic reactor, since the increase in the amount of foam allowed the reactor to reach better results and greater operational stability. The influence of the hydraulic retention time in the reactor performance was also proved. Very high retention times cause problems in the liquid-solid mass transference, while low retention times do not allow an adequate action of microorganisms. The best result for the reactor with an exclusive anaerobic operation was the 10 hour retention time, when it was possible to reduce the COD of a 389 +/- 70 mg/L gross sample to a 137 +/- 16 mg/L in average. On the other hand, for the anaerobic-aerobic operating reactor, the COD of a gross sample dropped from 259 +/- 69 mg/ L to 93 +/- 31 mg/L in average. Finally, comparing all the obtained results, it was possible to verify the importance of the anaerobic post treatment in the removal of a part of the organic matter not removed in an exclusively anaerobic treatment.
56

Exploring a Lab-scale Cascade Upflow Bioreactor System for Nitrogen Removal Via Biosorption Activated Media

Robles Lecompte, Alejandra 01 January 2023 (has links) (PDF)
Many Best Management Practices (BMPs) have been developed to reduce excessive nutrients in stormwater runoff and mitigate harmful algal blooms in downstream receiving water bodies. This study demonstrates a new BMP by comparing two green sorption media (i.e., specialty adsorbents) for nutrient removal in cascade upflow biofiltration systems operated in parallel. The proposed filtration technology can control hydraulic gradients, prevent clogging and settlements, and increase hydraulic loading while removing more nutrients in an integrated physicochemical and microbiological treatment process. The two green sorption media being tested in this study include zero-valent-iron and perlite-based green sorption media (ZIPGEM) and biochar, iron, and perlite-integrated green sorption media (BIPGEM). BIPGEM or ZIPGEM was installed in two identical upflow bioreactors operated in sequence within each biofiltration system compared mainly for nitrate removal at three influent conditions for process reliability assessment. In addition, kinetics studies were conducted and analyzed to improve the understanding of reactor design. Dissolved organic nitrogen was monitored by using FT-ICR MS (Fourier transform ion cyclotron resonance mass spectrometer) whereas population dynamics of nitrifiers and denitrifiers were quantified by using RT-PCR (real time polymerase chain reaction). The process reliability was compared and confirmed based on the nitrate removal efficiencies, microbial population, and oxidation-reduction potential variations across the two biofiltration systems with different green sorption media. Results indicated that ZIPGEM performed slightly better than BIPGEM and the two identical upflow bioreactors operated in sequence within each biofiltration system exhibited steady operation with higher hydraulic loading relative to the downflow settings in the literature.
57

Remoção de células e subprodutos de Microcystis spp. por dupla filtração, oxidação e adsorção / Removal of cells and by-products of Microcystis spp. in double filtration, oxidation and adsorption processes

Kuroda, Emília Kiyomi 18 December 2006 (has links)
Considerando o aumento da ocorrência de florações de cianobactérias e a possibilidade de formação de subprodutos em diversos mananciais destinados ao consumo humano, este trabalho teve como objetivo, avaliar a remoção de células e subprodutos de Microcystis spp. pelos processos de dupla filtração com filtração ascendente em pedregulho e de filtração descendente em areia, oxidação e adsorção com carvões ativados pulverizado e granular. Na fase 1 foram realizados ensaios de bancada para estabelecimento das condições operacionais dos ensaios a serem realizados em instalação piloto, utilizando-se água de estudo preparada com adição de cultura de cepa tóxica de Microcystis spp. e ou extrato de microcistinas. Em seguida, foram realizados ensaios em instalação piloto de escoamento contínuo para águas de estudo preparadas com adição de cultura de cepa tóxica de Microcystis spp. e de extrato de microcistinas – fase 2 e de material coletado no reservatório de Barra Bonita – SP - fase 3. A concepção de dupla filtração utilizada mostrou ser bastante eficiente na remoção de células de Microcystis spp. e, consequentemente, de microcistinas intracelulares, porém, a remoção ou degradação de microcistinas extracelulares só foi significativa com o emprego de processos complementares de oxidação e ou adsorção. Para as águas de estudo empregadas, não houve formação expressiva de subprodutos organohalogenados nos efluentes dos processos de tratamento, após serem submetidas à cloração e tempo de contato de 1 dia. Adicionalmente, foram realizados estudos prospectivos no sentido de avaliar a toxicidade de extrato, águas de estudo e efluentes dos processos de tratamento por meio de bioensaios com cladóceros e camundongos, além de biomonitoramento com a espécie de peixe Danio rerio. / Considering the increase in the frequency of cyanobacterial blooms and the possibility of by-product formation in water supply sources for human consumption, this work was carried out in order to evaluate the removal of cells and by-products of Microcystis spp. using the processes of double filtration (gravel upflow filtration of coagulated water followed by rapid sand downflow filtration), oxidation and adsorption in powdered and granular activated carbons. Bench scale assays were performed in phase 1 to determine the operational conditions of the tests to be performed in a continuous flow pilot plant, using a study water prepared with filtered water in the water treatment plant 2 of Sao Carlos and culture of a toxic strain of Microcystis spp. and/or microcystins extract. Based on the conditions stated in phase 1, phase 2 was carried out by performing tests in the pilot plant for study waters prepared with culture of toxic strain of Microcystis spp. and phase 3 of microcystins extract from material collect in the de Barra Bonita – SP reservoir. The double filtration system used resulted very efficient concerning the removal of cells of Microcystis spp., but, on the other hand, the removal or degradation of extracellular microcystins was significant with the use of complementary processes such as oxidation and or activated carbon adsorption. With regards to the waters studied, there wasn’t significant formation of by-products due to the oxidation of the effluent of each combination of processes, when submitted to chlorination with detention time of 1 day. Additionally, it was observed the toxicity effect by bioassays with crustaceans and mices, besides Danio rerio fish screening.
58

Produção de estruvita a partir de esgoto doméstico. / Production of struvite from domestic wastewater.

Sánchez Ledesma, Lina Marcela 09 October 2014 (has links)
A escassez das fontes de fósforo e o alto consumo de energia associado à produção de fertilizantes nitrogenados serão problemas que deverão ser enfrentados no futuro. A recuperação de nutrientes das águas residuárias na forma de estruvita tem sido considerada como uma alternativa para atenuar estes problemas. Na América Latina, a produção de estruvita a partir de esgoto ainda não é uma tecnologia bem conhecida e, portanto, a finalidade deste trabalho é contribuir com uma melhor compreensão dos fenômenos envolvidos. Para isso, a pesquisa foi dividida em três etapas: 1) produção de estruvita a partir de efluente de reator anaeróbio de fluxo ascendente com manto de lodo (RAFA); 2) produção de estruvita a partir de sobrenadante de digestor anaeróbio de lodo de um processo com remoção biológica de fósforo (DALRBF) e 3) influência do cálcio na estruvita produzida na etapa 2. Nas três etapas, ajustaram-se as concentrações de magnésio, a fim de obter razões fósforo:magnésio (P:Mg) pré-estabelecidas, e o pH entre 8,00 e 10,50. Os resultados da primeira etapa mostraram que não foi possível produzir estruvita no efluente do RAFA nas condições testadas. No entanto, foram observadas remoções de fósforo e de nitrogênio, devido à formação de fosfatos de cálcio e de magnésio amorfos. Os resultados da segunda etapa comprovaram a viabilidade de produção de estruvita de sobrenadante de DALRBF e mostraram que os consumos molares dos íons fosfato (PO43-), amônio (NH4+) e magnésio (Mg2+) ou as remoções destes (%) não devem ser os únicos parâmetros para avaliar a formação de estruvita, pois outros compostos cristalizam ou precipitam e reduzem a qualidade do mineral. Para um meio com condições semelhantes às testadas nesta etapa, uma razão P:Mg 1:2 e um pH igual a 9,50 asseguram a máxima recuperação de nutrientes como estruvita com concentração mínima de impurezas, facilitando seu posterior uso como fertilizante. Os resultados da terceira etapa mostraram que uma fase amorfa de fosfato de cálcio ou de magnésio se forma na superfície da estruvita. / The shortage of the phosphorus sources and high-energy consumption associated to the nitrogen fertilizers production will be problems in the future. The nutrient recovery from wastewater as struvite has been considered as an alternative to alleviate these problems. In Latin America, production of struvite from wastewater is not yet a wellknown technology and therefore the purpose of this work is to contribute to a better understanding of the phenomena involved. This research work was performed in three phases: 1) production of struvite from upflow anaerobic sludge blanket reactor effluent; 2) production of struvite from anaerobic digester supernatant of enhanced biological phosphorus removal process (ADS-EBPR) and 3) influence of calcium in the struvite produced in the phase 2. In three phases, the magnesium concentrations were adjusted to obtain the preset phosphorus:magnesium (P:Mg) ratios and the pH was adjusted between 8,00 and 10,50. The results of the first phase showed that it is not possible to produce struvite in the upflow anaerobic sludge blanket reactor effluent in the tested conditions. However, removal of nitrogen and phosphorus was observed because amorphous calcium and magnesium phosphates were produced. The results of the second phase showed that it is possible to produce struvite in the ADS-EBPR and the molar consumptions of phosphate (PO43-), ammonia (NH4+) and magnesium (Mg2+) or removals (%) should not be the only parameters to evaluate the struvite formation, because other compounds crystallize or precipitate and reduce the quality of the mineral. In the similar conditions tested in this phase, a P:Mg ratio 1:2 and pH 9,50 assure maximum nutrients recovery as struvite with minimum impurities concentration, facilitating its subsequent use as fertilizer. The results of the third phase showed that amorphous calcium or magnesium phosphates were produced on the struvite surface.
59

Remoção de substâncias húmicas na dupla filtração com filtro ascendente de pedregulho / Removal of humic substances in double filtration system using an upflow gravel filter

Benini, Bianca Dieile da Silva 25 April 2003 (has links)
Este trabalho foi realizado com o objetivo de avaliar o comportamento de um sistema de dupla filtração, utilizando filtro ascendente de pedregulho seguido de filtro rápido descendente na remoção de substâncias húmicas. A parte experimental foi realizada em uma instalação piloto, que utilizou como afluente a água do Ribeirão Feijão na qual foi adicionado extrato de substâncias húmicas, previamente extraído de solo turfoso por meio de extração alcalina, para que a cor verdadeira da água de estudo resultasse entre 90 e 110 uH. As condições de coagulação, como gradiente de velocidade, dosagem e pH, foram definidos em ensaios com jarteste. As taxas utilizadas no filtro ascendente em pedregulho foram de 80 e 120 m3/m2.dia e no sistema de filtração rápida descendente de 80, 120, 150, 180, 220 e 240 m3/m2.dia. As carreiras tiveram duração máxima de 72 horas. A utilização do critério de realização de Descargas de Fundos Intermediárias (DFIs), quando o efluente do Filtro Ascendente de Pedregulho (FAP) atingisse valor maior ou igual 50 uH, não permitiu aumento da cor no efluente final. O sistema de dupla filtração estudado foi eficiente na remoção de cor, atingindo diversas vezes remoção completa; outros parâmetros relativos à concentração de substâncias húmicas, como absorvância (254 nm) e Carbono Orgânico Dissolvido (COD), foram removidos entre 89,1 a 93,6% e 27,5 a 48,5% respectivamente. / The present work was carried out to evaluate the removal of humic substances in a double filtration system, comprising on upflow gravel prefilter followed by a rapid down flow filter. Raw water was abstracted from the influent took to the municipal water treatment Plant 2. Humic substances were extracted from peat through alkaline process. The concentrated solution was pumped to raw water in order to obtain true colour of 90-110 Hu in the influent to the pilot plant. Filtration rates studied were as follows: 80 and 120 m3/m2.day in the upflow filter 80, 120, 150, 180, 220 e 240 m3/m2.day in the down flow filter. Maximum filter run length was fixed in 72 hours. Intermediate down flushes in the upflow filter were performed during the run when the effluent colour reached 50 Hu. It is concluded that the system performed efficiently to remove colour; in most part of the effluent colour remained bellow 1 Hu. Absorbance (254 nm) removal resulted high (between 89,1% and 93,6%). Dissolved organic carbon resulted satisfactory (27,5% to 48,5%).
60

Avaliação exergoecológica de processos de tratamento de esgoto. / Exergology evaluation of wastewater treatment process.

Mora Bejarano, Carlos Humberto 24 March 2009 (has links)
O presente trabalho propõe uma metodologia científica, com critérios bem definidos, para avaliar e quantificar o desempenho ambiental e a renovabilidade de processos de tratamento de esgoto, numa base única: a exergia. O desempenho ambiental é quantificado através do cálculo da eficiência exergética ambiental, definida como a razão da exergia do efeito útil do processo pela exergia total consumida dos recursos humanos e naturais, incluindo todas as entradas exergéticas. O cálculo da renovabilidade é feito por meio do índice exergético de renovabilidade definido como como a razão entre a exergia dos produtos pela soma das exergias não renováveis, a exergia destruída, a exergia de desativação e a exergia das emissões e residuos. A metodologia foi aplicada a três processos de tratamento de esgoto: dois biológicos (aeróbio e anaeróbio) e um físico-químico (TQA). O cálculo dos indicadores exergéticos foi realizado para cada um destes processos e foi observado que o processo com maiores valores de desempenho ambiental e renovabilidade, considerando o metano e o lodo do processo como efeito útil, foi o processo RAFA Lagoa Facultativa, com valores respectivamente de n<exerg,amb> (0,983) e lâmbda(7,060). A análise dos resultados mostrou que a metodologia proposta é uma ferramenta útil na avaliação e comparação do desempenho ambiental e da renovabilidade de processos de tratamento de esgoto. / This work proposes a scientific methodology, with well defined criteria, to assess and quantify the environmental performance and renewability of wastewater treatment processes on a single base: the exergy. The environmental performance was measured by calculating the environmental exergy efficiency defined as the exergy ratio of the useful effect of the process to the total exergy consumed by human and natural resources, including all the exergy inputs. The renewability calculation was done using the renewability exergy index defined as the exergy ratio of the products to the sum of the non-renewable exergy, destroyed exergy, deactivation exergy and the emissions and waste exergy. The methodology was applied to three wastewater treatment processes: biological (aerobic and anaerobic) and physicochemical (CEPT) processes. The exergy indicators were calculated for each of these processes and it was observed that the process with the higher environmental performance and renewability values, considering the methane and sludge of process as useful effect, was the Facultative Lagoon UASB process, with values, respectively, of n<env,exerg>(0.983) and lambda(7.060). The results analysis showed that the proposed methodology is a useful tool in the evaluation and comparison of environmental performance and renewability of wastewater treatment processes.

Page generated in 0.0272 seconds