• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 4
  • Tagged with
  • 4
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Rädslans Yta : Är våta varelser mer hotfulla än torra? / The Surface of Fear : Are wet creatures more threatening than dry ones?

Jonsson, Anton January 2018 (has links)
Arbetet undersökte hur hotfull betraktaren uppfattade en varelse utifrån olika grader av våta alternativt torra ytegenskaper, genom enbart visuell perception. Arbetet inleds med en genomgång av tidigare forskning kring visuell perception, ytors relationer till fruktan samt hotfullhet i form och färg. Definitioner för begreppen ”Yta” och ”våt- och torrhet” skapades även, med vetenskapliga belägg. Artefakten som skapades för arbetet bestod av 10 stycken 2D-bilder, indelade i två bildserier med olika färgmättnad. Bilderna föreställde en och samma varelse som skapades med olika grader av våt- och torrhet på dess yta. En kvantitativ webbenkät användes för att undersöka respondenterna upplevda hotfullhet hos de olika bilderna. Resultatet visade att respondenterna upplevde bilderna som mer hotfulla ju våtare de blev, men ökningen i hotfullhet var marginell, andra faktorer verkade spela större roll i hur hotfull varelsen upplevdes.
2

Patientens uppfattningar av att leva med våt AMD : en fenomenografisk studie.

Syrjäoja, Sofie January 2017 (has links)
Bakgrund: Sjukdomen åldersrelaterad makuladegeneration (AMD) är en är av de vanligaste anledningarna till grav synnedsättning i västvärlden. Sjukdomen medför att den centrala synen försämras för patienten. Det finns en torr och en våt form. Med den våta formen sker synförsämringen i ett snabbare förlopp men kan behandlas med läkemedel som injiceras i ögats glaskropp. Synförsämringen skapar olika problem för patienten att hantera i deras vardagsliv. I relation till vardagliga aktiviteter så som socialt och fysiskt finns den närvarande. Syfte: Att beskriva patientens uppfattningar av att leva med sjukdomen våt AMD. Metod: En kvalitativ design har använts med en fenomenografisk forskningsansats. Patienter från en ögonmottagning i Mellansverige har enskilt intervjuats. Data har sedan analyserats enligt en fenomenografisk analys. Resultat: Fyra stycken beskrivningskategorier identifierades som handlade om patienternas uppfattningar av sin sjukdom. Medvetenhet om sjukdomen, förlust av självständighet, att kunna anpassa sig och att känna tillit till sjukvården. Slutsats: Att leva med sjukdomen våt AMD medför förändringar i patientens vardagsliv och påverkar det på olika sätt. För att kunna förstå patientens uppfattningar med att leva med sjukdomen är det viktigt att belysa och lyfta fram dessa för att kunna hitta metoder för att uppmärksamma denna patientgrupps behov av stöd och hjälp vid besöken på ögonkliniken.
3

Korrosionsstudie om nickel-krom-molybden legeringar i våt skrubber.

Garza, Simon, Shaqiri, Lundrim January 2016 (has links)
Arbetet som utförts är en material studie som inriktar sig på nickel-krom-molybdenbaserade legeringar som används i dagens våt skrubber. Eftersom kraven på mängden utsläpp av svaveldioxid är en viktig miljöfråga, skapar detta ett behov för användandet av en våt skrubber. Den här produkten befinner sig i anläggningar där förbränningsmotorer finns och förekommer i princip i alla större fartyg. Rökgasen som motorerna släpper ifrån sig är skadlig för miljön och därför absorberas flödet in till en våt skrubber där en förbränning sker. Rökgasen separeras med hjälp av ett antal sprinklers som är placerade ovanpå gas ingången i en skrubber. Med hjälp av havsvatten som samlas upp och sluts till skrubbern injiceras detta genom sprinklers sen vidare nedåt på rökgasen som separerar föroreningar ifrån den gasen som är tänkt ska kondensera genom och ut i atmosfären. Havsvatten tillsammans med föroreningarna samlas på botten av skrubbern och samlas i tankar. Denna miljö är väldigt skadlig för materialet som produkten består av, framför allt på botten där materialet riskerar att korrodera som mest. Arbetet beskriver ett antal typer av korrosion och förklarar innebörden av de olika typerna så att det enklare går att förstå sammanhanget med miljön och omständigheternas påverkan på legeringarna. Syftet i arbetet är att studera de olika legeringarna och beskriva de med hjälp av den litteraturstudie som gjorts. Med hjälp av insamlad data av tester som tidigare utförts enligt standard, har detta tolkats och bidragit till evalueringen av de olika legeringarna. De grundläggande tester som används vid evaluering av legeringarnas karaktär är tester där en bit av materialet doppas ned i en specifik lösning med olika omständigheter och villkor. Detta räcker inte för att säkerställa en hållbar livscykel för en våt skrubber och därför evalueras legeringarna även med hjälp av olika fälttester. Teoretiska studier på tester i aggressiva miljöer används för att resultera rangordningen av de olika materialen och även ett nytt material undersöks vid namnet alloy 2120. / This thesis work is a study of materials which focus on nickel-chromium-molybdenum-based alloys used in today’s wet scrubbers. Since the requirements for emissions of sulfur dioxide is a major environmental issue, this creates a need for the use of a wet scrubber. This product is in installations where combustion engines are available and are basically in all larger vessels. The flue gas that engines emit are harmful to the environment and for that reason, the flow is absorbed into a wet scrubber where combustion takes place. The flue gas is separated by a number of sprinklers placed above of the gas in a scrubber. Collected seawater is used to separate the gas through the sprinklers that injects the water on top of the flue gas where impurities is separated from the gas that will condense out to the atmosphere. The water fluid together with the contaminants is collected on the bottom of the scrubber and into the tanks. This environment is very harmful to the material that the product is made of, in particular on the bottom where the material is more susceptible for corrosion. The work describes several types of corrosion and the meaning of the different types so that the reader easily can understand the impact of the environment on the alloys. The type of corrosion that occurs primarily in scrubbers is pitting corrosion and is considerate to be a highly local type of corrosion, and the most dangerous type. Pitting occurs when the protective oxide layer does not have time to repassivate and can also lead to other types of corrosion. Due to the dangerous work environment, the risk for corrosion to occur is high and therefore, focus is put on this specific material group. The purpose of this work was to study the alloys and describe them with the help of a literature study. Using data collected from tests previously performed in accordance with standards, the collected data has been interpreted and contributing to the evaluation of the various alloys. The basic tests used in the evaluation of the nature of the alloy are tests in which a piece of material immersed in a specific solution with different circumstances and conditions. This is not enough to ensure a sustainable life cycle for a wet scrubber and therefore, alloys is evaluated using various field tests as well. Theoretical studies on tests in aggressive environments is used to result the ranking of the various materials and also a new material is examined by the name alloy 2120.
4

OCT (Optical Coherense Tomography) : Teknik och tillämpning

Lundkvist, Stefan January 2013 (has links)
Before year 1895, the doctors could only make a probable diagnosis based on what the patient could tell and it was hurt and there was no discernable change to the outside of the body. With X-ray, it was possible to see inside the patient without first cutting it, you can say that the X-ray was the starting point for diagnostic imaging.The further development of X-ray gave CT (Computed Tomography), where X-ray tubes and detectors rotate around the patient while the patient table moves. Besides CT also developed MRI (Magnetic Resonance Imaging), PET (Positron Emission Tomography) and Ultrasound. Common to these methods is that the produced 3D images.In 1990 a completely new approach for diagnostic imaging, OCT (optical coherence tomography), by measuring the phase shift and the intensity of reflected light, it provides real-time and non-destructive measurements (in vivo) a resolution of 1 to 15 microns, much higher than all other standard imaging techniques. You could say that OCT machine can be compared to ultrasound, which uses the reflection of sound waves to interpretation.The first OCT machines were of type TD (Time Domain), these had low resolution and low scanning speed. In 2005 came the SD-OCT, they had higher resolution and scanning speed, SD stands for spectral domain, SD-OCT is sometimes called FD-OCT as Fourier transformed signals and operating in the frequency domain.The development of OCT machines are only in their infancy, resolution, scanning speed and accuracy will increase all the time, this allows new uses and ways to diagnose developed. OCT can be used in such Oncology, MSD (Musculoskeletal disorders), cardiovascular medicine, teeth, nerves, but the largest field is the eye and then the back of the eye called the retina (retina).This thesis is limited to the eye, the purpose is to provide input to those who are likely to purchase an OCT-machine, but also show the measurement data OCT-machines are performing and how to use the OCT-machine more than to see age-related macular degeneration. Another aim is to increase understanding of the physics behind an OCT-machine for ease of understanding the output given.The manufacture/model that have selected for evaluation are Zeiss Cirrus 4000, Topcon 3D OCT-2000 and Heidelberg Spectralis, the reason is that there are only these three on the Swedish market and all are SD-OCT. The way to evaluate OCT-machines is to scan performance and what the various analysis programs can handle. Furthermore, each OCT-machine scans the macula and optic disk on a experimental person/ reference eye, in order to get the output of the precision, or if you want to call it repeatability, which is very important if one wants to follow a solitary disease course.The conclusion of this thesis is to OCT machines are quite similar. When it comes to ease of use when doing scans is the Cirrus is lightened by the use of the extra screen where you always look eye (iris camera), which makes it easy to adjust the sharpness and position of the mouse buttons. Topcon and Heidelberg is not difficult to use but requires more experience of the person making the OCT scans. Most measurement functions in the analysis program is Topcon and Heidelberg and best accuracy/repeatability is Heidelberg, both the macula and RFNL.OCT machine is a good tool to use on the anterior segment, but in the case the precision allows the precision used to monitor RNFL thickness changes in those with glaucoma. / <p>Validerat; 20131029 (global_studentproject_submitter)</p>

Page generated in 0.0203 seconds