Spelling suggestions: "subject:"validation off analytical methods"" "subject:"validation oof analytical methods""
21 |
[en] DEVELOPMENT AND INTRALABORATORY VALIDATION OF THE METHOD BY CAPILLARY MICELLAR ELECTROKINETIC CHROMATOGRAPHY FOR THE DETERMINATION OF VITAMIN K1 AND K3 IN GREEN TEA AND PHARMACEUTICAL SUPPLEMENTS / [pt] DESENVOLVIMENTO E VALIDAÇÃO INTRALABORATORIAL DO MÉTODO POR CROMATOGRAFIA ELETROCINÉTICA CAPILAR MICELAR PARA DETERMINAÇÃO DE VITAMINA K1 E K3 EM CHÁ VERDE E EM SUPLEMENTOS FARMACÊUTICOSTATIANE VIDAL DIAS GOMES 13 August 2012 (has links)
[pt] O desenvolvimento e validação de um método analítico para determinação de vitamina K é de fundamental importância considerando a crescente preocupação mundial com questões referentes à qualidade de vida, nutrição, saúde e meio ambiente, além da importância deste micronutriente na saúde. Desenvolveu-se um método baseado na cromatografia eletrocinética capilar micelar (MEKC) para a determinação das vitaminas K1 e K3. As condições ótimas de análise por MEKC foram obtidas a partir de estudo univariado de parâmetros experimentais e instrumentais (tampão borato 3,1 g.L(-1), pH igual a 8,5; CTAB 18,2 g.L(-1); acetonitrila 20 por cento v/v, 25 graus Celsius, 30 kV, Tigual a 15 s). Realizou-se um estudo com uma cela de caminho óptico alongado de modo a melhorar o limite de detecção (LOD) e o limite de quantificação (LOQ) do método. As curvas analíticas de ambas as vitaminas apresentaram comportamento linear e homoscedástico com valores de r próximos a 0,99. Os valores de LOD e de LOQ para a vitamina K1 e para a vitamina K3 ficaram na ordem de 10(-5) g.L(-1) e 10(-4) g.L(-1), respectivamente. A precisão do método apresentou valores entre 2 e 7 por cento para a área dos picos. As recuperações obtidas para a vitamina K1 foram de 101 mais ou menos 2 por cento e 103 mais ou menos 2 por cento para as amostras de suplemento vitamínico e chá verde, respectivamente. Para a vitamina K3, a recuperação obtida foi de 99 mais ou menos 3 por cento para a amostra de chá. Testes comparativos realizados entre o método proposto por MEKC e o método de referência baseado em HPLC demonstraram uma boa exatidão (tcalculado menor que ttabelado). A incerteza associada ao método desenvolvido apresentou valores entre 2 e 30 por cento, sendo as fontes mais relevantes aquelas associadas à construção da curva analítica e ao preparo das soluções. O método analítico desenvolvido pode contribuir para a realização de medições confiáveis e sensíveis de diferentes formas de vitamina K. / [en] The development and validation of an analytical method for determination of vitamin K is of paramount importance considering the growing worldwide concern with questions regarding the quality of life, nutrition, health and environment and the importance of this micronutrient in health. It is developed a method based on capillary micellar electrokinetic chromatography (MEKC) for the determination of vitamin K1 and K3. The optimal condition for analysis by MEKC were obtained by means of experimental and instrumental univariate study (borate buffer 3.1 gL(-1), pH equal 8.5; CTAB 18.2 gL(-1), 20 per cent acetonitrile v/v 25 celsius degrees, 30 kV, T equal 15 s). A study with a longer optical path-length capillary cell was performed to improve the detection limit (LOD) and the limit of quantification (LOQ) of the method. Analytical curves of both vitamins presented linear and homoscedastic behavior, with r values near 0.99. The values of LOD and LOQ for vitamin K1 and vitamin K3 were on the order of 10(-5) g.L(-1) and 10(-4) g.L(-1), respectively. The precision of the method was between 2 and 7 per cent for the peak area. Recoveries for vitamin K1 were 101 more or less 2 per cent and 103 more or less 2 per cent for samples of vitamin supplement and green tea, respectively. For vitamin K3, recovery obtained was 99 more or less 3 per cent for the sample tea. Comparative tests performed among the proposed method by MEKC and the reference method based on HPLC showed good accuracy (tcalculated less than ttabulated). The measurement uncertainty associated with the method developed showed values between 2 and 30 per cent, and the relevant sources were those associated with the analytical curve and the preparation of solutions. The developed analytical method can contribute to achieve sensitive and reliable measurements of different forms of vitamin K.
|
22 |
[en] METHODS FOR THE IMIDACLOPRID QUANTIFICATION IN AQUEOUS SOLUTIONS: METROLOGICAL VALIDATION AND COMPARISON BETWEEN UV-VIS SPECTROPHOTOMETRY AND HIGH-PERFORMANCE LIQUID CHROMATOGRAPHY / [pt] MÉTODOS DE QUANTIFICAÇÃO DE IMIDACLOPRID EM SOLUÇÕES AQUOSAS: VALIDAÇÃO METROLÓGICA E COMPARAÇÃO ENTRE ABSORCIOMETRIA MOLECULAR E CROMATOGRAFIA LÍQUIDA DE ALTA EFICIÊNCIAKELLY NEOOB DE CARVALHO CASTRO 21 May 2007 (has links)
[pt] Um procedimento analítico é considerado apropriado para
uma aplicação
específica quando é capaz de gerar resultados confiáveis,
que possibilitem a
tomada de decisão com grau de confiança adequado, sendo
sua adequação
consolidada mediante a realização de ensaios de validação.
Este trabalho
propõe a utilização de um procedimento analítico
alternativo, mais simples e
econômico, baseado na técnica espectrofotométrica de
absorção molecular,
para quantificação de imidacloprid, um inseticida
sistêmico, em amostras de
solução aquosa. Foi demonstrado que o procedimento
proposto é adequado ao
uso pretendido descrevendo-se, detalhadamente, cada etapa
da validação,
considerando-se os limites estabelecidos para cada
parâmetro de validação e
aplicando-se técnicas estatísticas apropriadas na
avaliação dos mesmos: análise
de variância, análise de regressão, testes de
significância, gráficos de controle e
a estimativa da incerteza de medição. As incertezas de
medição dos
procedimentos de rotina e alternativo foram estimadas e
comparadas às
tolerâncias estipuladas, estabelecendo o procedimento
alternativo como
adequado. Uma comparação experimental deste procedimento
com o de rotina
(baseado em HPLC) foi realizada como parte do protocolo de
validação. Além
da avaliação do procedimento para quantificação de
imidacloprid em nível de
traços, foi investigada também a possibilidade de sua
utilização, para a
quantificação do mesmo ingrediente ativo em produtos
formulados. Neste caso,
foi demonstrado, através da comparação das incertezas
estimadas às tolerâncias
estabelecidas, que o procedimento alternativo não é
adequado, por apresentar
incertezas na ordem de aproximadamente 50% do valor destas
tolerâncias, não
possuindo assim o rigor metrológico requerido para esta
aplicação. / [en] Fit for purpose analytical procedures must be sufficiently
reliable to support
any decision taken based on the generated results. In
order to achieve that,
consolidated adequacy evaluation of the analytical
procedure must be obtained
by performing validation experiments. In this work, an
alternative and simpler
spectrophotometric method for the quantification of
imidacloprid in aqueous
samples was compared to the HPLC-UV based reference method
used in
routine. The overall validation procedure started with a
detailed description of
each validation stage, followed by the settling of the
limits for each of the
validation parameters and then, applying the following
statistical techniques to
evaluate each of the parameters: ANOVA, regression
analysis, significance
tests, control charts and uncertainty estimation. The
measurement of
uncertainties estimation, based on ISO-GUM
recommendations, was done for
both analytical procedures (the alternative one and the
reference one). After
comparing these uncertainties with the tolerance values,
the adequacy of the
alternative proposed procedure was confirmed. Finally, by
consolidating the
validation, the experimental comparison of quantification
methods was
conducted. Besides evaluating the analytical procedure for
trace-level
imidacloprid quantification in water samples, the proposed
method was also
evaluated as the analytical procedure for imidacloprid
based formulated
products. In this case, it was demonstrated that the
spectrophotometric method
did not present the requested metrological requirements
for such application,
since the estimated uncertainties of the alternative
procedure were about 50 %
of the tolerance values.
|
23 |
Caracterização físico-química, desenvolvimento e validação de métodos analíticos para o extrato seco dos bulbos da espécie Rhodophiala bifida (Herb.) Traub com alto teor do alcaloide MontaninaAraújo, Mariele Brambilla de January 2017 (has links)
Os alcaloides têm apresentado diversas atividades biológicas. Entre eles, a montanina vem demonstrando um bom desempenho nesse sentido, como, atividade antioxidante, ação inibitória do crescimento de culturas bacterianas e importante atividade de inibição do crescimento de linhagens tumorais. Atualmente, não existem muitos relatos da sua caracterização ou métodos analíticos quantitativos disponíveis na literatura para atribuir seu teor. Assim, após purificação, a caracterização da montanina foi realizada por calorimetria exploratória diferencial (DSC), espectroscopia na região do ultravioleta (UV), infravermelho (IV), espectrometria de massas (CLAE-EM), ressonância magnética nuclear de hidrogênio (RMN1H), de carbono (RMN13C) e em 2D homo e heteronucleares tais como COSY (nJH-H, escalar), NOESY (nJH-H, dipolar), HSQC (1JH-C, escalar) e HMBC (nJH-C, escalar). Na sequência, foram desenvolvidos métodos empregando a cromatografia líquida de alta eficiência (CLAE) acoplada aos detectores ultravioleta e aerossol carregado (CLAE- UV/DAC) para a quantificação da montanina. Os mesmos foram validados, avaliando-se os parâmetros de especificidade, linearidade, intervalo, limite de detecção, limite de quantificação, precisão, exatidão e robustez. Os resultados obtidos foram avaliados por estatística descritiva e os métodos comparados pelo resultado da análise de variância (ANOVA). Desse modo, foram desenvolvidos procedimentos que podem ser aplicados para aprimorar o controle de qualidade, contribuindo para assegurar a eficácia terapêutica da montanina. / Alkaloids have several biological activities. Among them, montanine have shown antioxidant activity, inhibitory effect on bacterial growth and important activity inhibiting growth of some tumor cell lines. Currently, there are a few reports about its characterization as well as quantitative analytical methods to determine its purity. Thus, after a purification step, montanine will be characterized by its differential scanning calorimetry (DSC), ultraviolet spectroscopy (UV), infrared spectroscopy (IR), mass spectrometry (HPLC-MS), nuclear magnetic resonance of proton (NMR1H), carbon (NMR13C) and 2D homo and heteronuclear such as COSY (nJH-H, scalar), NOESY (nJH-H, dipolar), HSQC (1JH-C, scalar) and HMBC (nJH-C, scalar). Further, quantitation methods will be developed employing high-performance liquid chromatography (HPLC) coupled with ultraviolet and charged aerosol detectors (HPLC-UV/CAD). These methods will be validated regarding the parameters specificity, linearity, range, detection limit, quantitation limit, precision, accuracy and robustness. The results will then be evaluated by descriptive statistics and the developed methods will be compared using analysis of variance (ANOVA). Therefore, tests will be developed that can be used to improve quality control, helping to ensure the therapeutic efficacy of montanine.
|
24 |
Desenvolvimento e validação de metodologia analítica, ensaio de dissolução e estudo de estabilidade do carbonato de lodenafila / Development and validation of analytical methodology, dissolution test and stability study of lodenafil carbonateCodevilla, Cristiane Franco January 2012 (has links)
O carbonato de lodenafila é um inibidor da fosfodiesterase tipo 5, desenvolvido no Brasil, o qual é um dímero formado por duas moléculas de lodenafila ligadas por uma ponte carbonato. Encontra-se disponível sob a forma de comprimidos. Não existe monografia disponível para este fármaco em nenhum código oficial. Assim, o objetivo do presente estudo foi desenvolver métodos analíticos para análise qualitativa e quantitativa do carbonato de lodenafila em comprimidos, avaliação da estabilidade frente à degradação forçada, contemplando a cinética de fotodegradação, identificação e estudo de citotoxicidade in vitro dos produtos de degradação majoritários e desenvolvimento do teste de dissolução baseado em dados in vivo. A caracterização da substância química de referência foi realizada através da faixa de fusão por calorimetria exploratória diferencial, métodos espectrofotométricos na região do infravermelho (IV) e do ultravioleta (UV), assim como espectroscopia de ressonância magnética nuclear de 1H e 13C. Os métodos por cromatografia em camada delgada (CCD), espectrofotometria no UV, cromatografia líquida de alta eficiência (CLAE) e eletroforese capilar (EC) foram utilizados para identificar o fármaco na forma farmacêutica. Os seguintes métodos de análise quantitativa do fármaco em comprimidos foram desenvolvidos e validados: método indicativo da estabilidade por CLAE, espectrofotometria na região do UV e EC. Todos cumpriram com os parâmetros descritos pelas guias de validação e não apresentaram diferença significativa na determinação do fármaco. A cinética de fotodegradação do carbonato de lodenafila apresentou cinética de primeira ordem. Dois produtos majoritários encontrados na fotodegradação foram identificados por cromatografia líquida de ultra eficiência acoplada à espectrometria de massas (CLUE-MS/MS) como ácido 4-etoxi-3-(1-metil-7-oxo-3-propil-6,7-diidro- 1H-pirazol [4,3-d] pirimidina-5-il) benzenossulfônico e ácido 4-etoxi-3-(1-metil-7-oxo- 3-propil-6,7-diidro-1H-pirazol [4,3-d] pirimidina-5-il) benzenossulfínico. A avaliação da citotoxicidade in vitro indicou que a amostra de carbonato de lodenafila degradada não apresentou toxicidade. O teste de dissolução foi desenvolvido e validado utilizando como meio de dissolução 900 mL de HCl 0,1 M + lauril sulfato de sódio 1,5% (p/v), a 37 ± 0,5°C, pás a 25 rpm e quantificação por espectrofotometria no UV. O perfil de dissolução apresentou cinética de primeira ordem. De acordo com os resultados obtidos, todos os métodos propostos podem ser utilizados no controle de qualidade do carbonato de lodenafila. / Lodenafil carbonate is a PDE5 inhibitor developed in Brazil, which is a dimer formed by two lodenafil molecules linked by a carbonate bridge. It is currently available in tablets. There is no monograph available for this drug in any official code. Thus, the purpose of the present study was the development of analytical methods for qualitative and quantitative analysis of LC in tablets, evaluation of drug stability in forced degradation, comprising the determination of photodegradation kinetic, identification and in vitro cytotoxicity study of two major degradation products and develop a dissolution test based on in vivo data. The characterization of the reference chemical substance was performed by: melting range by differencial scanning calorimetry, infrared (IR) and ultraviolet (UV) spectrophotometry methods, as well as the 1H and 13C nuclear magnetic resonance spectroscopy. The methods by thin-layer chromatography (TLC), UV spectrophotometry, high-performance liquid chromatography (LC) and capillary electrophoresis (CE) were used to identify the drug in pharmaceutical formulations. The following methods, applied to the assay of the drug in tablets were developed and validated: a stability-indicating HPLC method, UV spectrophotometry and CE. All of them met the criteria described by the validation guidelines and showed no significant statistically difference in the drug determination. The photodegradation kinetics of lodenafil carbonate showed firstorder kinetics. Two degradation products found by photodegradation were identified by ultra performance liquid chromatography-tandem mass spectrometry (UPLCMS/ MS) as 4-ethoxy-3-(1-methyl-7-oxo-3-propyl-6,7-dihydro-1H-pyrazolo [4,3- d]pyrimidin-5-yl)-benzenesulfonic acid and 4-ethoxy-3-(1-methyl-7-oxo-3-propyl-6,7- dihydro-1H-pyrazolo [4,3-d]pyrimidin-5-yl) benzenesulfinic acid. The in vitro cytotoxicity evaluation indicated that the lodenafil carbonate degraded sample did not show toxicity. A dissolution test was developed and validated using 900 mL of 0.1 M HCl + 1.5% sodium lauryl sulfate (w/v), at 37 ± 0.5 °C as dissolution medium, paddle at 25 rpm and quantitation by UV spectrophotometry. The dissolution profile showed first order kinetics. According to the obtained results, all proposed methods can be used in the quality control of lodenafil carbonate.
|
25 |
Desenvolvimento de Método Indicativo da Estabilidade, Ensaio de Dissolução e Estudo Preliminar da Estabilidade e Citotoxicidade do Ciprofibrato em Formas Farmacêuticas / Development of a stability-indicating method, dissolution assay and preliminary study of ciprofibrate stability and citotoxicity in pharmaceutical formulationsHellwig, Fernanda Macke 25 July 2014 (has links)
Submitted by Sandro Camargo (sandro.camargo@unipampa.edu.br) on 2015-05-08T02:50:46Z
No. of bitstreams: 1
127110044.pdf: 1980288 bytes, checksum: 8b5f5461083c2fddcb65dc2aa052e8ee (MD5) / Made available in DSpace on 2015-05-08T02:50:46Z (GMT). No. of bitstreams: 1
127110044.pdf: 1980288 bytes, checksum: 8b5f5461083c2fddcb65dc2aa052e8ee (MD5)
Previous issue date: 2014-07-25 / O ciprofibrato é um fármaco hipolipemiante amplamente utilizado para o tratamento de
hipertrigliceridemia. Encontra-se comercialmente disponível na forma de comprimidos e
cápsulas manipuladas, e, até o momento, não existem monografias oficiais para o controle de
qualidade em suas formas farmacêuticas. O presente trabalho objetivou o desenvolvimento e
validação de método cromatográfico indicativo de estabilidade para análise quantitativa do
ciprofibrato nas formas farmacêuticas comerciais, desenvolvimento de ensaio de dissolução,
avaliação da estabilidade do fármaco em condições de degradação forçada, contemplando a
determinação da cinética de fotodegradação e o estudo da citotoxicidade do fármaco em
presença dos produtos de degradação. A validação do método analítico foi realizada de acordo
os principais Guias Oficiais, considerando os seguintes parâmetros analíticos: especificidade,
linearidade, precisão, exatidão e robustez. O método cromatográfico descrito nesse trabalho
demonstrou-se adequado para determinação de ciprofibrato em comprimidos e cápsulas
manipuladas. O método de dissolução foi desenvolvido e validado para avaliação da liberação
do fármaco em comprimidos seguindo os parâmetros de especificidade, linearidade, precisão,
exatidão e robustez. O meio utilizado foi ácido clorídrico com adição de 1 % de lauril sulfato
de sódio, aparato pás, rotação de 50 rpm e quantificação por espectrofotometria na região do
ultravioleta. A cinética de fotodegradação em acetonitrila, frente à luz UVC 254 nm
apresentou reação de segunda ordem para a matéria-prima e ambas as formas farmacêuticas.
A avaliação da citotoxicidade indicou que a amostra de ciprofibrato na presença dos produtos
de degradação obtidos na fotólise não aumenta seu efeito tóxico quando comparado ao
fármaco intacto. Os resultados obtidos neste trabalho demonstram a importância do
aprofundamento dos estudos nesta área para garantir a segurança e eficácia terapêutica dos
produtos farmacêuticos comercializados. / Ciprofibrate is a hypolipidemic drug widely used to treat hypertriglyceridemia. It is
commercially available as tablets and capsules, and, nowadays, there are no official
monographs regarding the quality control to this drug in its pharmaceutical forms. The present
study aimed to develop and validate a stability indicating chromatographic method for
quantitative analysis of ciprofibrate in commercial pharmaceutical forms, development of the
dissolution test, to evaluate the drug stability under forced degradation, comprising the
determination of the photodegradation kinetics and the study of drug cytotoxicity in the
presence of the degradation products. The validation of the analytical method was performed
according to parameters described in the Official Guides considering the following analytical
parameters: specificity, linearity, precision, accuracy and robustness. The method described in
this work had demonstrated to be adequate for ciprofibrate determination in tablets and
capsules. The dissolution study was conducted by paddle method (50 rpm) at 37 ± 0,5 °C in
900 mL of hydrochloric acid with addition of 1 % sodium lauryl sulfate, and quantification by
spectrophotometry in the ultraviolet. The photodegradation kinetics in acetonitrile under UVC
light showed a second-order kinetics for the raw material and both dosage forms. The
cytotoxicity evaluation indicated that the ciprofibrate sample in the presence of the
degradation products obtained under photolysis does not increase its toxic effect when
compared to the intact drug. The results demonstrate the importance of this type of study to
ensure the safety and efficacy of marketed pharmaceutical products.
|
26 |
Caracterização físico-química, desenvolvimento e validação de métodos analíticos para o extrato seco dos bulbos da espécie Rhodophiala bifida (Herb.) Traub com alto teor do alcaloide MontaninaAraújo, Mariele Brambilla de January 2017 (has links)
Os alcaloides têm apresentado diversas atividades biológicas. Entre eles, a montanina vem demonstrando um bom desempenho nesse sentido, como, atividade antioxidante, ação inibitória do crescimento de culturas bacterianas e importante atividade de inibição do crescimento de linhagens tumorais. Atualmente, não existem muitos relatos da sua caracterização ou métodos analíticos quantitativos disponíveis na literatura para atribuir seu teor. Assim, após purificação, a caracterização da montanina foi realizada por calorimetria exploratória diferencial (DSC), espectroscopia na região do ultravioleta (UV), infravermelho (IV), espectrometria de massas (CLAE-EM), ressonância magnética nuclear de hidrogênio (RMN1H), de carbono (RMN13C) e em 2D homo e heteronucleares tais como COSY (nJH-H, escalar), NOESY (nJH-H, dipolar), HSQC (1JH-C, escalar) e HMBC (nJH-C, escalar). Na sequência, foram desenvolvidos métodos empregando a cromatografia líquida de alta eficiência (CLAE) acoplada aos detectores ultravioleta e aerossol carregado (CLAE- UV/DAC) para a quantificação da montanina. Os mesmos foram validados, avaliando-se os parâmetros de especificidade, linearidade, intervalo, limite de detecção, limite de quantificação, precisão, exatidão e robustez. Os resultados obtidos foram avaliados por estatística descritiva e os métodos comparados pelo resultado da análise de variância (ANOVA). Desse modo, foram desenvolvidos procedimentos que podem ser aplicados para aprimorar o controle de qualidade, contribuindo para assegurar a eficácia terapêutica da montanina. / Alkaloids have several biological activities. Among them, montanine have shown antioxidant activity, inhibitory effect on bacterial growth and important activity inhibiting growth of some tumor cell lines. Currently, there are a few reports about its characterization as well as quantitative analytical methods to determine its purity. Thus, after a purification step, montanine will be characterized by its differential scanning calorimetry (DSC), ultraviolet spectroscopy (UV), infrared spectroscopy (IR), mass spectrometry (HPLC-MS), nuclear magnetic resonance of proton (NMR1H), carbon (NMR13C) and 2D homo and heteronuclear such as COSY (nJH-H, scalar), NOESY (nJH-H, dipolar), HSQC (1JH-C, scalar) and HMBC (nJH-C, scalar). Further, quantitation methods will be developed employing high-performance liquid chromatography (HPLC) coupled with ultraviolet and charged aerosol detectors (HPLC-UV/CAD). These methods will be validated regarding the parameters specificity, linearity, range, detection limit, quantitation limit, precision, accuracy and robustness. The results will then be evaluated by descriptive statistics and the developed methods will be compared using analysis of variance (ANOVA). Therefore, tests will be developed that can be used to improve quality control, helping to ensure the therapeutic efficacy of montanine.
|
27 |
Entacapona : desenvolvimento e validação de métodos analíticos, método de dissolução e estudo preliminar de estabilidade / Entacapone : development and validation of analytical methods, dissolution method and preliminary study of stabilityPaim, Clésio Soldateli January 2007 (has links)
Entacapona, inibidor da catecol-o-metiltransferase, é utilizada como terapia adjuvante à associação de levodopa + carbidopa no tratamento da doença de Parkinson. No Brasil encontra-se disponível na forma de comprimidos revestidos com o nome comercial de Comtan®. O objetivo desse trabalho foi desenvolver e validar métodos analíticos para o controle de qualidade da entacapona em comprimidos revestidos e método de dissolução, bem como, estudos preliminares de estabilidade durante o desenvolvimento do método indicativo de estabilidade por cromatografia líquida de alta eficiência (CLAE) e na determinação da cinética de fotodegradação. Devido à falta da substância química de referência de entacapona, realizou-se a extração do fármaco a partir dos comprimidos e a caracterização qualitativa e quantitativa por calorimetria diferencial de varredura (DSC), espectrofotometria na região do infravermelho (IV), ressonância magnética nuclear (RMN) e volumetria em meio não-aquoso. Métodos utilizando cromatografia em camada delgada (CCD), espectrofotometria na região do ultravioleta (UV) e CLAE foram utilizados para análise qualitativa de entacapona. A validação dos métodos para determinação quantitativa (UV e CLAE) foi realizada de acordo os parâmetros das principais Guias Oficiais (BRASIL, 2003; ICH, 2005; USP 30, 2007). O método de dissolução foi desenvolvido e validado de acordo com a USP. Os métodos qualitativos e quantitativos descritos nesse trabalho demonstraram-se adequados para determinação de entacapona em comprimidos revestidos. Para o método de dissolução as seguintes condições foram selecionadas: solução tampão acetato pH 5,3 como meio, utilizando pás a 50 rpm. A cinética de fotodegradação em metanol, frente à luz UV indicou reação de segunda ordem. Análises por CLAE-EM/EM sugerem que o produto de fotodegradação formado seja o isômero geométrico de entacapona (Z-entacapona). / Entacapone, inhibitor of the catechol-O-methyltransferase, is used as adjunct with levodopa + carbidopa association in the treatment of Parkinson’s disease. In Brazil it is available in tablets coated with the commercial name of Comtan®. The aim of this work was to develop and validate analytical methods for the quality control of entacapona in coated tablets, as well as, preliminary studies of stability during the development of stability-indicating high-performance liquid chromatography (HPLC) method and determination of photodegradation kinetics. Due to the lack of entacapone reference standard, it was necessary to extract the drug by the tablets and the qualitative and quantitative characterization was carried out by differential scanning calorimetry (DSC), infrared spectroscopy (IR), nuclear magnetic resonance (NMR) and non-aqueous titration of weak acid. Methods using thin-layer chromatography (CCD), ultraviolet spectroscopy (UV) and HPLC were performed to entacapone qualitative analysis. The validation of the methods for quantitative determination (UV and CLAE) was accomplished of agreement the parameters of the main Official Guides (BRASIL, 2003; ICH, 2005; USP 30, 2007). The dissolution test was developed and validate in according by USP. The qualitative and quantitative methods described in this study demonstrated to be adequate to determination of entacapone in coated tablets. For dissolution test the following conditions were selected: buffer acetate pH 5,3 as medium, using paddles at 50 rpm. The photodegradation kinetics in methanol, front to UV light indicated the second-order reaction. LC-MS/MS method results suggest that the photodegration product was the geometric isomer of entacapone (Z-entacapone).
|
28 |
Cloridrato de milnaciprana cápsulas : metodologia analítica, ensaio de dissolução e estudo de estabilidade / Milnacipran hydrochloride capsules: analytical methodology, dissolution test and study of stabilityDias, Carolina Lupi January 2011 (has links)
O cloridrato de milnaciprana (MNC) é um inibidor da recaptação da serotonina e noradrenalina (IRSN), produzido na forma farmacêutica cápsula, Ixel, Dalcipran e Toledomin, para o tratamento da depressão, e como comprimido, sob o nome comercial Savella, indicado no manejo da fibromialgia. Levando-se em consideração que não existem métodos oficiais para o doseamento do MNC em produto acabado, faz-se necessário o desenvolvimento e validação de métodos para assegurar a qualidade da forma farmacêutica. Deste modo, o objetivo deste trabalho foi a validação de métodos analíticos para o controle de qualidade do MNC cápsulas e a realização de estudo da degradação forçada do fármaco. A identificação e caracterização do fármaco foram realizadas através da análise do ponto de fusão, DSC, rotação específica e IV. Para a quantificação foram validados, segundo normas da ICH, os métodos UV-D2, CLAE e EC. A análise estatística demonstrou equivalência entre os métodos UV-D2 e CLAE, assim como entre CLAE e EC, para doseamento do MNC cápsulas. O teste de dissolução foi desenvolvido e validado utilizando cestas (50 rpm) em HCl 0,01M como meio de dissolução. A porcentagem de fármaco dissolvido foi determinada por ambos os métodos, CLAE e UV-D2. Os parâmetros cinéticos (ED% e t80%) da dissolução foram determinados e o modelo de Hixson-Crowell é o que melhor descreve a cinética de dissolução das cápsulas. A influência das condições de armazenamento da formulação farmacêutica no perfil de dissolução também foi avaliada. No estudo de degradação forçada, o MNC foi submetido à radiação UV (254 nm) e à oxidação com peróxido de hidrogênio. A CLAE foi o método empregado na análise do teor e pureza das amostras submetidas às degradações. Os resultados demonstraram a sensibilidade do fármaco nas condições testadas, havendo redução significativa de seu teor e a formação de produtos de degradação. A fotodegradação do MNC demonstrou cinética de 1ª ordem para o fármaco no estado sólido e para a solução das cápsulas, enquanto para o fármaco em solução demonstrou cinética de ordem zero. / Milnacipran hydrochloride (MNC) is a serotonin and noradrenaline reuptake inhibitor (SNRI), produced as capsules, Ixel, Dalcipran and Toledomin, for the treatment of depression, and as tablets, under the trade name Savella, indicated in the management of fibromyalgia. Considering that there are no official methods for the determination of the MNC capsules, it is necessary to develop and validate methods to ensure the quality of pharmaceutical formulation. Thus, the objective of this study was the validation of analytical methods for quality control of the MNC capsules and the forced degradation studies of the drug. The identification and characterization of the drug were performed by analyzing the melting point, DSC, specific rotation and IR. For the quantification were validated a second-derivative UV spectrophotometric (UV-D2), HPLC and a CE methods, according to ICH guide. Statistical analysis showed that the methods UV-D2 / HPLC, and HPLC / CE were equivalent to assay MNC capsules. The dissolution test was developed and validated using baskets (50 rpm) in 0.01N HCl as dissolution medium. The percentage of dissolved drug was determined by both methods (HPLC and UV-D2). The kinetic parameters (dissolution efficiency% and t80%) of drug release were determined and the Hixson-Crowell model is which best describes the dissolution kinetics of the capsules. The influence of storage conditions of the pharmaceutical formulation in the dissolution rate was also evaluated. In forced degradation study, the MNC was subjected to UV (254nm) and oxidation with hydrogen peroxide. The HPLC method was employed to analyze the assay and purity of samples subjected to degradation. The results showed levels of the drug decreased significantly and the presence of its degradation products. The photodegradation of MNC showed first order kinetics of reaction to the drug at solid state and to capsules solution, but the drug solution presented zero order kinetics.
|
29 |
Desenvolvimento de metodologia para análise de ceftiofur sódico e estudo da estabilidade / Development of methodology for ceftiofur sodium analysis and stability studySouza, Marinês Jost e January 2008 (has links)
Este trabalho objetivou o desenvolvimento e validação de métodos analíticos para determinação de ceftiofur pó para solução injetável e o estudo da fotoestabilidade do fármaco. Os métodos por cromatografia em camada delgada, cromatografia líquida de alta eficiência (CLAE), espectrofotometria no ultravioleta (UV) foram utilizados para análise qualitativa do fármaco na forma farmacêutica. A determinação quantitativa foi realizada através dos métodos cromatografia líquida de alta eficiência, espectrofotometria no ultravioleta e ensaio microbiológico método de difusão em ágar - cillindros em placas, delineamento 3x3, avaliando-se os parâmetros descritos pelas guias de validação. Os resultados obtidos através destes métodos foram comparados estatisticamente por ANOVA, que indicou não haver diferenças estatisticamente significativas entre os mesmos. Estudo preliminar da estabilidade do ceftiofur frente a degradação alcalina, ácida, oxidativa e fotolítica mostrou a oxidação, a temperatura, a luz e a condição alcalina como fatores importantes da degradação. O fármaco é instável às radiações UV-C, em maior grau, e UV-A (degradação menos intensa), em solução. A cinética de fotodegradação do ceftiofur sódico em solução aquosa demonstrou cinética de primeira ordem de reação. / The aim of this study was the development and validation of analytical methods to the determination of ceftiofur sodium in powder for injectable preparation and the photostability study of the drug after reconstitution of the pharmaceutical dosage form with injectable water. Thin-layer chromatography (TLC), high performance liquid chromatography (HPLC) and ultraviolet spectrophotometry (UV), methods were employed to the qualitative analysis of the drug in pharmaceutical formulation. The quantitative determination was performed through the validation of HPLC, UV spectrophotometry and microbiological assay 3x3 using the cylinder plate, evaluating the guidances validation parameters. The results obtained by three methods were compared by ANOVA, which indicated that they are equivalent. Preliminary study of ceftiofur through alkaline, acid, oxidative and fotolitic degradation shows sensibility to oxidation, light and alkaline medium. The drug is unstable to UV-C and UV-A radiations, both in solution, being the degradation on UV-C more intense. The photodegradation kinetics of ceftiofur sodium solutions show first-order kinetic of reaction.
|
30 |
Desenvolvimento e validação de metodologia analítica, ensaio de dissolução e estudo de estabilidade do carbonato de lodenafila / Development and validation of analytical methodology, dissolution test and stability study of lodenafil carbonateCodevilla, Cristiane Franco January 2012 (has links)
O carbonato de lodenafila é um inibidor da fosfodiesterase tipo 5, desenvolvido no Brasil, o qual é um dímero formado por duas moléculas de lodenafila ligadas por uma ponte carbonato. Encontra-se disponível sob a forma de comprimidos. Não existe monografia disponível para este fármaco em nenhum código oficial. Assim, o objetivo do presente estudo foi desenvolver métodos analíticos para análise qualitativa e quantitativa do carbonato de lodenafila em comprimidos, avaliação da estabilidade frente à degradação forçada, contemplando a cinética de fotodegradação, identificação e estudo de citotoxicidade in vitro dos produtos de degradação majoritários e desenvolvimento do teste de dissolução baseado em dados in vivo. A caracterização da substância química de referência foi realizada através da faixa de fusão por calorimetria exploratória diferencial, métodos espectrofotométricos na região do infravermelho (IV) e do ultravioleta (UV), assim como espectroscopia de ressonância magnética nuclear de 1H e 13C. Os métodos por cromatografia em camada delgada (CCD), espectrofotometria no UV, cromatografia líquida de alta eficiência (CLAE) e eletroforese capilar (EC) foram utilizados para identificar o fármaco na forma farmacêutica. Os seguintes métodos de análise quantitativa do fármaco em comprimidos foram desenvolvidos e validados: método indicativo da estabilidade por CLAE, espectrofotometria na região do UV e EC. Todos cumpriram com os parâmetros descritos pelas guias de validação e não apresentaram diferença significativa na determinação do fármaco. A cinética de fotodegradação do carbonato de lodenafila apresentou cinética de primeira ordem. Dois produtos majoritários encontrados na fotodegradação foram identificados por cromatografia líquida de ultra eficiência acoplada à espectrometria de massas (CLUE-MS/MS) como ácido 4-etoxi-3-(1-metil-7-oxo-3-propil-6,7-diidro- 1H-pirazol [4,3-d] pirimidina-5-il) benzenossulfônico e ácido 4-etoxi-3-(1-metil-7-oxo- 3-propil-6,7-diidro-1H-pirazol [4,3-d] pirimidina-5-il) benzenossulfínico. A avaliação da citotoxicidade in vitro indicou que a amostra de carbonato de lodenafila degradada não apresentou toxicidade. O teste de dissolução foi desenvolvido e validado utilizando como meio de dissolução 900 mL de HCl 0,1 M + lauril sulfato de sódio 1,5% (p/v), a 37 ± 0,5°C, pás a 25 rpm e quantificação por espectrofotometria no UV. O perfil de dissolução apresentou cinética de primeira ordem. De acordo com os resultados obtidos, todos os métodos propostos podem ser utilizados no controle de qualidade do carbonato de lodenafila. / Lodenafil carbonate is a PDE5 inhibitor developed in Brazil, which is a dimer formed by two lodenafil molecules linked by a carbonate bridge. It is currently available in tablets. There is no monograph available for this drug in any official code. Thus, the purpose of the present study was the development of analytical methods for qualitative and quantitative analysis of LC in tablets, evaluation of drug stability in forced degradation, comprising the determination of photodegradation kinetic, identification and in vitro cytotoxicity study of two major degradation products and develop a dissolution test based on in vivo data. The characterization of the reference chemical substance was performed by: melting range by differencial scanning calorimetry, infrared (IR) and ultraviolet (UV) spectrophotometry methods, as well as the 1H and 13C nuclear magnetic resonance spectroscopy. The methods by thin-layer chromatography (TLC), UV spectrophotometry, high-performance liquid chromatography (LC) and capillary electrophoresis (CE) were used to identify the drug in pharmaceutical formulations. The following methods, applied to the assay of the drug in tablets were developed and validated: a stability-indicating HPLC method, UV spectrophotometry and CE. All of them met the criteria described by the validation guidelines and showed no significant statistically difference in the drug determination. The photodegradation kinetics of lodenafil carbonate showed firstorder kinetics. Two degradation products found by photodegradation were identified by ultra performance liquid chromatography-tandem mass spectrometry (UPLCMS/ MS) as 4-ethoxy-3-(1-methyl-7-oxo-3-propyl-6,7-dihydro-1H-pyrazolo [4,3- d]pyrimidin-5-yl)-benzenesulfonic acid and 4-ethoxy-3-(1-methyl-7-oxo-3-propyl-6,7- dihydro-1H-pyrazolo [4,3-d]pyrimidin-5-yl) benzenesulfinic acid. The in vitro cytotoxicity evaluation indicated that the lodenafil carbonate degraded sample did not show toxicity. A dissolution test was developed and validated using 900 mL of 0.1 M HCl + 1.5% sodium lauryl sulfate (w/v), at 37 ± 0.5 °C as dissolution medium, paddle at 25 rpm and quantitation by UV spectrophotometry. The dissolution profile showed first order kinetics. According to the obtained results, all proposed methods can be used in the quality control of lodenafil carbonate.
|
Page generated in 0.2074 seconds