• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 361
  • 158
  • 58
  • 39
  • 7
  • 6
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 3
  • 3
  • Tagged with
  • 745
  • 745
  • 146
  • 140
  • 85
  • 68
  • 67
  • 54
  • 53
  • 39
  • 39
  • 36
  • 36
  • 35
  • 34
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
481

Fourier transform holography for magnetic imaging

Duckworth, Thomas Andrew January 2013 (has links)
State-of-the art Fourier transform holography (FTH) techniques use x-ray magnetic circular dichroism (XMCD) as a contrast mechanism for element-specfi c imaging of magnetic domains. With the soft x-ray Nanoscience beamline at Diamond Light Source in the UK, and the Dragon beamline at the European Synchrotron Radiation Facility (ESRF) in France, the possibility of new methods to study nanostructured magnetic systems has been demonstrated. The ability to record images without the use of lenses, in varying magnetic fi elds and with high spatial resolution down to 30 nm has been used to study in-plane magnetism of 50 nm thin permalloy (NiFe alloy) nanoelements. The holographic technique used extended reference objects rather than conventional pinhole references, which allowed a high flexibility on the direction of magnetisation that is probed. The element specific nature of the imaging, with the additional choice in the directions of magnetisation that are probed has been used to study dipolar interactions in a hard/Ta/soft [Co/Pt]30/Ta/Py multi-layered system. Images of the out-of-plane magnetised domains of [Co/Pt]30 were found to bare strong spatial resemblance to the in-plane domains of the permalloy. The domain structure is thought to be magnetostatically imprinted into permalloy during the growth stage of the lm, where stray elds generated by the adjacent Co/Pt multilayer influence the formation of domains in the permalloy. Strong resemblance between the two layers could be found at remanence within a pristine sample, however the similarities disappear after the sample was exposed to a saturating magnetic field. This disagreed with micromagnetic simulations performed in The Object Oriented MicroMagnetic Framework (OOMMF) program, and an explanation for the observations has been sought in the growth process of the multi-layered fi lm, with conditions that are diffi cult to recreate in the model. Optical holography has been used for preliminary insight into implementing a method of FTH in a reflective geometry at soft x-rays wavelength. With scattering chambers at BESSY II in Germany and at the Stanford Synchrotron Radiation Lightsource (SSRL) in California the possibility of reducing scattered noise in a hologram recorded in a reflective geometry has been investigated. Studies into specular and dif use reflections have been performed optically however the use of extended references alone may alleviate the current problem at x-ray wavelengths which lie in the weak signal given by a reflective point-like reference source.
482

L-Shell X-Ray Production Cross Sections for ₂₀Ca, ₂₆Fe, ₂₈Ni, ₂₉Cu, ₃₀Zn, ₃₁Ga, and ₃₂Ge by Hydrogen, Helium, and Lithium Ions

McNeir, Michael Ridge 05 1900 (has links)
L-shell x-ray production cross sections are presented for Fe, Ni, Cu, Zn, Ga, and Ge by 0.5- to 5.0-MeV protons and by 0.5- to 8.0-MeV helium ions and Ca, Fe, Ni, Cu, and Ge by 0.75- to 4.5-MeV lithium ions. These measurements are compared to the first Born theory and the perturbed-stationary- state theory with energy-loss, Coulomb deflection, and relativistic corrections (ECPSSR). The results are also compared to previous experimental investigations. The high precision x-ray measurements were performed with a windowless Si(Li) detector. The efficiency of the detector was determined by the use of thin target atomic-field bremsstrahlung produced by 66.5 keV electrons. The measured bremsstrahlung spectra were compared to theoretical bremsstrahlung distributions in order to obtain an efficiency versus energy curve. The targets for the measurement were manufactured by the vacuum evaporation of the target element onto thin foils of carbon. Impurities in the carbon caused interferences inthe L-shell x-ray peaks. Special cleansing procedures were developed that reduced the impurity concentrations in the carbon foil, making the use of less than 5 μg/cm^2 targets possible. The first Born theory is seen to greatly overpredict the data at low ion energies. The ECPSSR theory matches the data very well at the high energy region. At low energies, while fitting the data much more closely than the first Born theory, the ECPSSR theory does not accurately predict the trend of the data. This is probably due to the onset of molecular-orbital effects, a mechanism not accounted for in the ECPSSR theory.
483

Avaliação de sistemas de controle automático de exposição em tomografia computadorizada / Evaluation of Automatic Exposure Control Systems in Computed Tomography

Reina, Thamiris Rosado 15 August 2014 (has links)
O desenvolvimento da tecnologia de tomografia computadorizada (TC) trouxe maiores possibilidades em medicina diagnóstica. É um método não invasivo de se explorar o corpo humano detalhadamente. Com o aumento das aplicações em TC, aumenta a preocupação com as altas taxas de dose administradas quando comparada com outras modalidades de diagnóstico por imagem. A comunidade científica e os fabricantes uniram esforços para alcançar níveis menores de dose possíveis, sem comprometer a qualidade da imagem diagnóstica. O maior e relativamente novo avanço nessa busca para diminuir os níveis de dose é o controle automático de exposição (CAE) em TC. Esses sistemas foram projetados para ponderar a distribuição de dose ao longo do comprimento de varredura e entre pacientes, levando em consideração o tamanho e as diferentes densidades de tecidos irradiados. Baseando-se na geometria de aquisição em TC, os sistemas CAE são altamente complexos. Sendo assim, sua forma de funcionamento ainda não é inteiramente conhecida. O presente trabalho tem como objetivo avaliar o desempenho clínico dos sistemas CAE, suas susceptibilidades ao usuário e, com isso, ajudar na otimização de dose em pacientes. A abordagem utilizada para avaliar os sistemas CAE de três dos maiores fabricantes de TC no Brasil, General Electric, Philips e Toshiba, foi pela extração dos valores de corrente anódica do cabeçalho da sequência de imagens no padrão DICOM, medição e análise do ruído das imagens dessas sequências e a medição da distribuição da dose ao longo do comprimento de varredura nas superfícies e dentro de dois simuladores de paciente de formatos diferentes. A variação da corrente anódica de cada equipamento de TC associada à qualidade da imagem resultante fornece o desempenho do sistema CAE. As medições de distribuição de dose fornecem o perfil de dose resultante da modulação de corrente. Medições com e sem o sistema CAE acionado foram feitas para quantificar a importância em termos de dose desses sistemas. Os resultados obtidos permitem otimizações no uso dos sistemas CAE e, consequentemente, a redução da dose no paciente sem comprometer a qualidade diagnóstica da imagem. / The development of the computed tomography (CT) technology has brought wider possibilities on diagnostic medicine. It is a non-invasive method to see the human body in details. As the CT application increases, it raises the concern about patient dose, because the higher dose levels imparted compared to other diagnostic imaging modalities. The radiology community (radiologists, medical physicists and manufacturer) are working together to find the lowest dose level possible, without compromising the diagnostic image quality. The greatest and relatively new advance to lower the patient dose is the automatic exposure control (AEC) systems in CT. These systems are designed to ponder the dose distribution along the patient scanning and between patients taking into account their sizes and irradiated tissue densities. Based on the CT scanning geometry, the AEC-systems are very complex and their functioning is yet not fully understood. This work aims to evaluate the clinical performance of AEC-systems and their susceptibilities to assist on possible patient dose optimizations. The approach to evaluate the AEC-systems of three of the leading CT manufacturers in Brazil, General Electric, Philips and Toshiba, was the extraction of tube current modulation data from the DICOM standard image sequences, measurement and analysis of the image noise of those image sequences and measurement of the dose distribution along the scan length on the surface and inside of two different phantoms configurations. The tube current modulation of each CT scanner associated to the resulted image quality provides the performance of the AEC-system. The dose distribution measurements provide the dose profile due to the tube current modulation. Dose measurements with the AEC-system ON and OFF were made to quantify the impact of these systems regarding patient dose. The results attained give rise to optimizations on the AEC-systems applications and, by consequence, decreases the patient dose without compromising the diagnostic image quality.
484

Medida da seção de choque de ionização atômica da camada K de Ta e Te por impacto de elétrons com energias do limiar até 100 keV / Measurements of cross sections for K-shell ionization of Ta and Te by electron impact from threshold to 100 keV

Santos, Osvaldo Camargo Botelho dos 19 May 2016 (has links)
Neste trabalho são apresentadas medidas de seção de choque de ionização para a camada K do Te e Ta por impacto de elétrons, realizadas no acelerador Microtron do Instituto de Fsica da Universidade de São Paulo (IFUSP). Os alvos de Te e Ta foram produzidos por evaporação e por pulverização catódica (sputtering), respectivamente, sobre filmes de Carbono. Os raios-X emitidos nos ângulos de 35, 90 e 131 graus em relação a direção do feixe de elétrons incidente foram observados por detectores de HPGe, cuja eficiência foi determinada com fontes radiativas de 133 Ba, 152 Eu e 241 Am. A energia do feixe cobriu o intervalo desde o limiar de ionização té 100 keV. Para determinar a densidade superficial de massa dos alvos foram feitas medidas de espalhamento Rutherford (Rutherford Backscattering Spectrometry) (RBS) no Laboratório de Análise de Materiais por Feixes Iônicos (LAMFI) do IFUSP, e os espectros adquiridos foram analisados utilizando os programas MultiSIMNRA e SIMNRA, que fornecem o perfil de profundidade da amostra. Os resultados obtidos para a seção de choque de ionização de ambos os elementos (Te e Ta) apresentam magnitude maior que os valores calculados com a teoria DWBA, onde o termo transversal da hamiltoniana de interação foi obtido utilizando a teoria de PWBA. O aumento observado é de aproximadamente 3% para o Te e 10% para o Ta, aumentando, portanto, com o número atômico do elemento. / The K-shell ionization cross sections of Te and Ta by electron impact were measured using the Microtron accelerator of Institute of Physics of the University of Sao Paulo (IFUSP). Thin Te and Ta targets were obtained by evaporation and sputtering, respectively, on thin Carbon backings. The X-rays emitted at 35, 90 and 131 degrees to the incident electron beam direction were detected by HPGe detectors, whose efficiencies were determined using 133 Ba, 152 Eu and 241 Am radioactive sources. The beam energy covered the interval from the ionization threshold up to 100 keV. The target surface mass densities were measured by Rutherford Backscattering Spectrometry (RBS) using the Tandem van de Graaff accelerator of the Laboratório de Análise de Materiais por Feixes Iônicos (LAMFI) at the IFUSP, and the spectra were analyzed using the Multi-SIMNRA code, which provides the sample depth profile. The resulting ionization cross section of both elements (Te and Ta) are greater than expected from calculations based on the DWBA theory and determining the matrix elements of the transverse term in the PWBA approximation. The observed diferences are approximately 3% for Te and 10% for Ta, therefore increasing with the atomic number of the element.
485

Bioecologia e tratamento quarentenário de Ceratitis capitata (Wiedemann 1824) (Diptera: Tephritidae) com raios X em uvas de mesa do Submédio do Vale do São Francisco / Bioecology and quarantine treatment of Ceratitis capitata (Wiedemann 1824) (Diptera: Tephritidae), with x-rays on table grapes in the São Francisco Valley

Pacheco, Maylen Gómez 30 November 2016 (has links)
O Submédio do Vale do São Francisco (VSF), que compreende parte dos estados da Bahia e de Pernambuco, é considerado atualmente o principal polo de produção de uvas frescas para exportação do Brasil. Entre as principais pragas que afetam essa cultura na região destaca-se a mosca-das-frutas, Ceratitis capitata, conhecida como moscamed ou mosca-do-mediterrâneo. Para a viticultura do VSF, populações elevadas de C. capitata representam o principal problema quarentenário para as exportações de uvas in natura, e tratamento quarentenário a frio, na pós-colheita, é obrigatório para uvas que se destinam aos Estados Unidos, Japão e Mercosul, onerando o custo final de produção. Visando aperfeiçoar as estratégias de manejo de C. capitata nessa cultura, o presente trabalho teve como objetivos estudar a biologia e comportamento desse inseto em cultivares de uvas de mesa produzidas no VSF, assim como avaliar o uso da radiação X como tratamento pós-colheita de cachos de uvas. Dados de estudos de preferência de oviposição e biologia de C. capitata em quatro cultivares de uvas de mesa, duas vermelhas (?Benitaka\' com semente e ?Crimson\' sem semente) e duas brancas (?Itália\' com semente e ?Festival\' sem semente) mostraram que esse inseto manifesta preferência de oviposição por bagas de cultivares vermelhas (Benitaka e Crimson), em condições de livre escolha. A cultivar de uva utilizada pelas larvas de C. capitata como alimento influenciou no desenvolvimento e sobrevivência dos estágios imaturos biológico, bem como no comportamento reprodutivo, longevidade e parâmetros demográficos das coortes de C. capitata recuperadas. Os valores estimados de Ro, rm e ? para coortes estudadas reafirmam que C. capitata se caracteriza por ser uma espécie com um alto potencial de crescimento e que as cultivares avaliadas constituem hospedeiros favoráveis à multiplicação desse inseto. Além disso, os resultados obtidos mostraram que C. capitata manifesta preferência de oviposição em cachos de uva Itália com maturação fisiológica mais avançada, em condições de escolha. No entanto, as fêmeas podem iniciar o ataque nas bagas, em parreirais desta variedade, aos 60 dias após a poda das plantas, quando os frutos ainda apresentam características físico-químicas desfavoráveis para a oviposição e desenvolvimento das fases imaturas, tais como: elevada firmeza e acidez e baixo teor de SST. As doses letais, DL99,9968, para inibir a emergência de adultos, quando aplicadas sobre ovos de 48h e larvas jovens (L1) infestando bagas de uvas Itália, foram estimadas em 12,08 e 20,44 Gy, respectivamente. Parâmetros químicos e sensoriais não foram afetados pela exposição das uvas às diferentes doses de raios X testadas, após 72h de armazenamento. Os conhecimentos biológicos, comportamentais e demográficos obtidos na presente pesquisa contribuirão ao aperfeiçoamento das estratégias de manejo de C. capitata nesta cultura, nas condições do VSF / The Lower Basin of the San Francisco Valley (VSF), which includes part of the states of Bahia and Pernambuco, is currently considered the major exporter and producer of table grapes in Brazil. Ceratitis capitata, also known as Moscamed or Mediterranean fly is among the main pests affecting fruit crops in the region. For the viticulture of the VSF, high populations of C. capitata are considered the main quarantine problem for exports of fresh table grapes, and for that reason post-harvest quarantine cold treatment is compulsory for grapes aimed to markets like the United States, Japan and Mercosur, adding additional charges to the final production cost. In order to improve the management strategies against C. capitata in this crop, this research aimed to study the biology and behavior of this insect in some table grape varieties grown in the VSF, as well as evaluate the use of Xrays as post-harvest treatment in table grape bunches. Studies on C. capitata oviposition preference and biology in four varieties of table grapes, two red (\'Benitaka\' seeded and \'Crimson\' seedless) and two white (\'Itália\' seeded and \'Festival\' seedless) showed that this insect expresses an oviposition preference for berries on red cultivars (Benitaka and Crimson), under free choice conditions. The table grape cultivar used for medfly larvae as food also influenced the development and survival of biologically immature stages as well as on reproductive performance, longevity and demographic parameters of C. capitata cohorts originating from the studied table grape varieties studied. The estimated values of Ro, rm and ? for the studied cohorts reaffirm that C. capitata is characterized by being a specie with a high growth potential and that the cultivars used in this research are favorable hosts for the multiplication of this insect. In addition, the results showed that C. capitata under choice conditions has clear preference of oviposition in \'Itália\' bunches in advanced physiological maturity. However, females can start attacking berries of this variety in vineyards, only 60 days after pruning, when the fruits still have unfavorable physicochemical characteristics for oviposition and immature stages development, such as high firmness and acidity and low in SST. The lethal dose, DL99,9968 to inhibit the emergence of adults when applied on 48 hours eggs and young larvae (L1) infesting \'Itália\' grape berries were estimated at 12,08 and 20,44 Gy, respectively. Chemical and sensory parameters were not affected by the exposure of table grapes to the different X-ray doses tested after 72 hours of storage. Biological, behavioral and demographic knowledge obtained in this study will contribute to the improvement of C. capitata management strategies in this crop under the VSF conditions
486

Estabelecimento de um sistema padrão primário para raios X de energias baixas com uma câmara de ionização de ar livre / Establishment a primary standard system for low energy X-rays using a free air ionization chamber

Silva, Natália Fiorini da 22 March 2016 (has links)
Neste trabalho foi estabelecido um sistema padrão primário para raios X de energias baixas (10 kV a 50 kV), utilizando uma câmara de ionização de ar livre de cilindros concêntricos da marca Victoreen (modelo 481-5) no Laboratório de Calibração de Instrumentos (LCI) do Instituto de Pesquisas Energéticas e Nucleares (IPEN/CNEN-SP). Para isso foi desenvolvido um novo protocolo de alinhamento da câmara de ionização no sistema de radiação e foi feita uma modificação no suporte dos micrômetros utilizados para o movimento dos cilindros internos. Os resultados obtidos nos testes de estabilidade e de caracterização ficaram dentro dos limites estabelecidos pelas normas IEC 61674 e IEC 60731. Foram determinados também os fatores de correção para atenuação de fótons no ar, transmissão e espalhamento no diafragma, espalhamento e fluorescência, e recombinação iônica. Esses valores foram comparados com os valores obtidos pelo laboratório padrão primário alemão,Physikalisch-Technische Bundesanstalt (PTB), mostrando boa concordância. Por último, foi determinado o valor absoluto da grandeza taxa de kerma no ar para as qualidades padronizadas de mamografia de feixes diretos WMV28 e WMV35 e feixes atenuados WMH28 e WMH35; os resultados são compatíveis, com diferença máxima de 3,8% com os valores obtidos utilizando o sistema padrão secundário do LCI. / In this work a primary standard system was established for low energy X-rays (10 kV to 50 kV), using a free air ionization chamber with concentric cylinders, Victoreen (Model 481-5), at the Calibration Laboratory of Instruments (LCI) of the Instituto de Pesquisas Energéticas e Nucleares (IPEN/CNEN-SP). For this, a new ionization chamber alignment protocol was developed for the radiation system and a modification on the micrometer housing used for the movement of the internal cylinders was made. The results obtained for the stability and characterization tests showed to be within the limits established by the standards IEC 61674 and IEC 60731. The correction factors for photon attenuation in the air, transmission and scattering in the diaphragm, scattering and fluorescence and ion recombination were also determined. These values were compared with those obtained by the German primary standard laboratory, Physikalisch-Technische Bundesanstalt (PTB), showing good agreement. Finally, the absolute values of the quantity air kerma rate for the standard qualities direct beams MWV28 and WMV35 and the attenuated beams WMH28 and WMH35 were determined; the results are in agreement, with a maximum difference of 3,8% with the values obtained using the secondary standard system of LCI.
487

Medida do alinhamento atômico de Ta, W e Au por impacto de elétrons pela distribuição angular dos raios x L / Measurement of atomic alignment of Ta, W and Au by electron impact from L x-ray angular distribution

Barros, Suelen Fernandes de 18 May 2018 (has links)
Foram realizadas medidas do alinhamento atômico do Ta, W e Au depois da ionização da subcamada L3 desses elementos por impacto de elétrons, via distribuição angular das linhas de raios x L, empregando alvos finos. As medições foram realizadas na linha de feixe de 10100 keV do Microtron de São Paulo. Os alvos foram confeccionados no Laboratório de Filmes Finos, pela técnica de deposição física de vapor (alvo de Au), e no Laboratório de Materiais Magnéticos, pela técnica de sputtering (alvos de Ta e W), enquanto que a caracterização deles foi realizada no Laboratório de Materiais e Feixes Iônicos, pela técnica de espectrometria de retroespalhamento Rutherford. O Microtron de São Paulo, bem como os laboratórios onde os alvos foram confeccionados e caracterizados, estão no Instituto de Física da Universidade de São Paulo. Os raios x decorrentes da ionização dos alvos foram detetados simultaneamente por três Silicon Drift Detectors localizados a 31°, 90° e 125° com relação à direção do feixe incidente. A determinação da eficiência de pico dos detetores foi realizada com um modelo analítico testado separadamente. As intensidades das linhas do multipleto de raios x L foram ajustadas em um único procedimento empregando funções Voigt para descrevê-las. O parâmetro de alinhamento A20 foi estimado a partir do conjunto de intensidades das linhas Ll, L1 e L2. A fim de comparar os resultados experimentais com as previsões teóricas foi calculado o parâmetro de alinhamento com a aproximação de Born de ondas planas não relativística, empregando as aproximações de HartreeSlater e DiracHartreeSlater para descrever os potenciais atômicos. Os resultados experimentais confirmaram a emissão não isotrópica dos raios x decorrentes de vacâncias preenchidas na subcamada L3, sendo que a magnitude desta anisotropia varia com a energia do feixe de elétrons incidente. Além disso, foram observadas anisotropias de sinais opostos para as linhas L1 e L2. A dependência em energia do parâmetro de alinhamento A20 mostra uma queda rápida de A20, com duas inversões de sinal, uma em torno de 2 E/E(L3) e outra em torno de 8 E/E(L3), e um valor não nulo de alinhamento em torno de 10 E/E(L3), para os três elementos estudados. A comparação dos resultados experimentais com os cálculos realizados mostra um bom acordo ate cerca de 5 E/E(L3) para o feixe de elétrons incidente, a partir deste ponto o experimento evidencia uma segunda inversão no sinal de A20, que não é prevista por essa teoria. Este é, a nosso saber, o primeiro trabalho a quantificar o alinhamento atômico na ionização de átomos pesados por impacto de elétrons, via distribuição angular de raios x na faixa de 1 a 10 E/E(L3). / Measurements of the atomic alignment of Ta, W and Au after the ionization of the L3 subshell of these elements were performed by electron impact via the angular distribution of x-ray lines employing thin targets. The targets were made in the Laboratório de Filmes Finos, by the technique of physical vapor deposition (Au target), and in the Laboratório de Materiais Magnéticos, by the sputtering technique (Ta and W targets), while their characterization was performed in the Laboratório de Materiais e Feixes Iônicos, by Rutherford Backscattering Spectrometry. The Microtron of São Paulo, as well as the laboratories where the targets were made and characterized, are placed at Instituto de Física of the Universidade de São Paulo. The x-rays from the ionization of the targets were detected simultaneously by three Silicon Drift Detectors placed at 31°, 90° and 125° with respect to the direction of the incident beam. The determination of the full energy peak efficiency of the detectors was performed with an analytical model previously tested. In the data analysis the L x-ray multiplet lines were fitted in a single procedure employing Voigt functions to describe them, and the Ll, L1 and L2 lines were employed simultaneously in the estimation of the alignment parameter A20. In order to compare the experimental results with the theoretical predictions, the alignment parameter was calculated with the non-relativistic plane-wave Born approximation using HartreeSlater and DiracHartreeSlater atomic potentials. The experimental results confirmed the nonisotropic emission of x-rays from filled vacancies in the L3 subshell, with the magnitude of this anisotropy varying with the energy of the incident electron beam. In addition, anisotropies of opposite signs were observed for the L1 and L2 lines. The energy dependence of the alignment parameter A20 shows a sharp fall of A20, with two sign inversions, one around 2 E/E(L3) and another around 8 E/E(L3), and a non-zero alignment value around 10 E/E(L3), for the three studied elements. Comparison of the experimental results with the performed calculations shows a good agreement up to about 5 E/E(L3) for the incident electron beam, from which the experiment evidences a second inversion in the sign of A20, which is not predicted by this theory. This is, to our knowledge, the first work to quantify the atomic alignment in the ionization of heavy atoms by electron impact, via an angular distribution of x-rays in the interval from 1 to 10 E/E(L3).
488

Dosimetria fotoacústica e piroelétrica de radiação x na faixa de diagnostico. / Photoacoustic and pyroelectric dosimetry in the x ray diagnostic range.

Carvalho, Aparecido Augusto de 16 October 1987 (has links)
Apresentaremos nesta tese três novos tipos de dosímetros de radiação, projetados para medir radiação X, na faixa de diagnóstico: o dosímetro de radiação fotoacústico pulsado, o dosímetro de radiação piroelétrico e o dosímetro de radiação piroelétrico pulsado. Estudamos também o dosimetro de radiação fotoacústico com o objetivo de compará-lo com os novos dosímetros desenvolvidos. Propomos uma metodologia para calibração de um dosímetro fotoacústico que prescinde da calibração de sua resposta em um campo conhecido de radiação ionizante. Apresentaremos um modelo teórico para explicar os resultados obtidos com o dosímetro de radiação piroelétrico pulsado. Os resultados encontrados mostram que os dosímetros desenvolvidos são do tipo calorimétrico, sendo a resposta deles linear com a taxa de fluência de energia da radiação X. / In this thesis we present three new types of radiation dosimeters, designed to measure X-rays in its diagnostic region: the pulsed photo acoustical radiation dosimeter, the pyroeletric radiation dosimeter and the pulsed pyroelectric radiation dosimeter. We also study the photo acoustical radiation dosimeter with the scope of to compare its characteristics with the characteristics of the new developed dosimeters. We propose a methodology for calibration of a photo acoustical dosimeter which doesn´t require the calibration of its response in a known field of ionizing radiation. We present a theoretical model to explain the results produced by the pulsed pyroelectric radiation dosimeter. The obtained results show that the developed dosimeters are of calorimetric type, being linear its response with the X-ray energy fluency rate.
489

Sensibilidade de análises de raios X para detecção de injúrias mecânicas, imediatas e latentes, em sementes de soja e relações com o potencial fisiológico / Sensibility of X-rays analysis for the detection of immediate and latent mechanical damages in soybeans seeds, and their relationships with physiological potential

Carvalho, Tereza Cristina de 07 August 2009 (has links)
As injúrias mecânicas, com efeitos imediatos e latentes, se caracterizam por causarem problemas para a produção de sementes de soja. O objetivo dessa pesquisa foi verificar a ocorrência de injúrias mecânicas, pelo teste de raios X em sementes de soja, colhidas com diferentes teores de água, determinar as possíveis alterações do potencial fisiológico das sementes, provocada por injúrias, logo após as colheitas e após seis meses de armazenamento, e comparar a utilização dos raios X e dos testes de hipoclorito de sódio e de tetrazólio, para detectar a ocorrência de diferentes graus de injúrias mecânicas nas sementes de soja. Para a pesquisa, foram utilizadas sementes de soja dos cultivares Embrapa 48 e FTS Águia que têm diferenças no teor de lignina do tegumento. As sementes foram produzidas e colhidas, manual e mecanicamente, com 18%, 15% e 12% de água e, imediatamente após a colheita, avaliadas quanto ao teor de água e às injúrias mecânicas. Após a secagem, a qualidade das sementes foi determinada pelos testes de germinação, emergência da plântula, tetrazólio (viabilidade e vigor), envelhecimento acelerado, hipoclorito de sódio e sanidade. Após a avaliação inicial, as sementes foram armazenadas (20°C e 45% UR) e analisadas após seis meses. Os resultados obtidos indicam que a utilização dos raios X possibilita a identificação das injúrias mecânicas, de efeito imediato, nas sementes de soja dos cultivares Embrapa 48 e FTS Águia, entretanto, as injúrias de efeitos latentes não são identificadas; o potencial fisiológico das sementes é afetado pelo tipo da colheita e pelo teor de água das sementes; o teste de raios X não tem a mesma eficiência que os testes de hipoclorito e de tetrazólio para determinar as injúrias mecânicas das sementes de soja. / Mechanical damages, with immediate and latent effects, are characterized to cause problems in soybean seed production. The goal of this research was to verify the occurrence of mechanical damages with X-rays in soybean seeds harvested with different levels of seed moisture content, determining the possible alterations in seeds physiological potential caused by physical injuries, right after the harvest and after six months of storage, and to compare the use of X-rays with the use of sodium hypochlorite and tetrazolium tests to detect the occurrence of different levels of mechanical damages in these seeds. The soybean seeds were from cultivars Embrapa 48 and FTS Águia, which have differences in lignin content in seed coat. The seeds were produced and harvested by hand and mechanically with the moisture contents of 18%, 15% and 12%, and were evaluated according to their seed moisture content and mechanical damages immediately after the harvest. After drying, seed quality was determined by germination, seedling emergence, tetrazolium (viability and vigor), accelerated aging, sodium hypochlorite and sanity tests. After the initial evaluation, the seeds were kept in storage conditions (20°C and 45% RAH) and analyzed after six months. The results indicated that the use of X-rays allows the identification of mechanical damages with immediate effects in the soybean seeds, cultivars Embrapa 48 and FTS Águia, but damages with latent effects were not identified; seed physiological potential is affected by harvesting method and seed moisture content; Xray method does not have the same efficiency as sodium hypochlorite and tetrazolium tests to determine seed mechanical damages in the soybean seed.
490

Detector de raios-X sensível à posição. / X-rays detector sensitive to the position.

Macchione, Eduardo Luiz Augusto 04 December 1990 (has links)
Um contador a gás, com multifios, sensível à posição, para a detecção de raios X foi construído utilizando linhas de atraso integradas para leitura da posição. Seis linhas de atraso (50ns de atraso cada, frequência de corte de 40MHz) cobrem um comprimento sensível total de 150mm, possuindo uma razão do atraso total pelo tempo de subida dos sinais na linha adequadas para a detecção em posição raios X de 5,9keV do ANTIPOT. 55 Fe com alta resolução. Testes usando a forneceram uma não-linearidade linha de integral máxima menor que 0,1% e não-linearidade diferencial máxima de ±4,0%, com o detector utilizando a mistura 700torr. Testes similares foram feitos usando de Ar-CH IND 4 (90%-10%) a a linha de 8,04keV de um tubo de raios X de Cu. Uma resolução total de 330m, e as mesmas não-linearidades integral e diferencial foram obtidas. Com a finalidade de t.est.ar o comportamento do detector sob condições experimentais reais, duas diferentes amostras foram analisadas na região de espalhamento em baixo ângulo. As amostras analisadas foram o carvão vítreo e o dodecil sulfato de sódio (SLS). O feixe de raios X foi colimado por um conjunto de fendas, com 50,um cada uma delas e separadas de 98mm. A distância entre a amostra e o detector era de 404,5mm, fazendo com que a região sensível do detector cobrisse um ângulo de espalhamento de ±12 °. Foram obtidos um raio de giro de 22 Å para o carvão vítreo e um dos parâmetros da rede cristalina c de 39,1 Å para o SLS. Estes resultados estão de acordo com trabalhos anteriores obtidos com técnicas tradicionais de maior dispêndio de tempo que utilizam detectores de Nal(T1) e chapas fotográficas em uma câmara de Laue. / A multiware position sensitive gas counter for X-Ray detection was developed in our laboratory making use or commercial delay-lines for position sensing. Six delay-line chips (50ns delay each 40Mhz cut-off frequency) cover a total sensitive length of 190mm leading to a delay-risetime ratio that allows for a high-resolution position detection. Tests using the 5,9keV X-Ray line from a 55Fe source an integral linearity better than 0,1% and a maximum differential linearity or ±4,0% were obtained operating the detector with an Ar-CH 4 (90%-10%) gas mixture at 700torr. Similar tests were performed using the 8,04keV line from a Cu X-Ray tube. A total resolution or 330m, and the same integral and differential linearities were obtained. In order to check the detector performance under usual experimental conditions two different samples were analyzed in the low scattering-angle region. The samples analyzed were vitreous carbon and sodium dodecyl sulfate (SLS). The X-Rays were collimated by a set or slits each 50m wide separated by 98mm. The distance between the sample and the detector was 404,5mm, so that the detector covered a scattering angle of ±12°. A radius of gyration of 22Å for vitreous carbon and a crystallographic parameter of 39,1Å for SLS were obtained. These values are in good agreement with those obtained with the more time-consuming traditional techniques making use of a rotating NaI(T1) detector and photographic plates with a Laue camera.

Page generated in 0.0401 seconds