• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 290
  • 20
  • 20
  • 2
  • 1
  • 1
  • Tagged with
  • 334
  • 260
  • 255
  • 229
  • 208
  • 153
  • 143
  • 119
  • 107
  • 72
  • 66
  • 58
  • 50
  • 47
  • 46
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
131

Avalia??o in vitro da ades?o de fibroblastos NIH3T3 estimulados por bFGF em discos de tit?nio

Thaddeu, Camilo Santos 05 December 2007 (has links)
Made available in DSpace on 2015-04-14T14:50:47Z (GMT). No. of bitstreams: 1 399015.pdf: 142110 bytes, checksum: c5ffb33c81a7c9cbade03c8428376c8e (MD5) Previous issue date: 2007-12-05 / Uma conex?o est?vel entre a superf?cie de tit?nio e os tecidos a sua volta ? um dos mais importantes pr?-requisitos para o sucesso a longo prazo dos implantes. Para isso, uma forte e efetiva ades?o das c?lulas na superf?cie do biomaterial ? requerida. O objetivo desse estudo foi o de avaliar a ades?o de fibroblastos estimulados por Fator de Crescimento de Fibroblastos b?sico (bFGF) em discos de tit?nio. Para esse estudo foram produzidos 30 discos de tit?nio com superf?cie lisa. Esses discos foram colocados em placas de cultura e sobre eles foi inserido meio com fibroblastos NIH3T3, estimulados por bFGF, no grupo teste e sem este fator de crescimento no controle. As amostras foram obtidas em 3 horas, 24 horas e 48 horas. Foram feitas 10 imagens com Microsc?pio Eletr?nico de Varredura em cada disco, totalizando 300 micrografias. Como resultado foi encontrado que existe uma diferen?a significativa no crescimento de fibroblastos nos tr?s tempos deste experimento, do grupo onde o bFGF foi administrado.
132

Avalia??o histol?gica do contato osso-implante e estabilidade de implantes com superf?cies modificadas : estudo experimental em t?bias de coelhos / Effect of implant surface properties on osseointegration, bone-to-implant contact and stability of modified sand-blasted acid-etched implants : an experimental study in rabbits

Nunes, Leandro Soeiro de Souza 26 March 2014 (has links)
Submitted by Setor de Tratamento da Informa??o - BC/PUCRS (tede2@pucrs.br) on 2015-05-14T20:53:10Z No. of bitstreams: 1 468625 - Texto Completo.pdf: 2863238 bytes, checksum: 3e057c78a6b6e5cfbd0cf6767d59dd26 (MD5) / Made available in DSpace on 2015-05-14T20:53:10Z (GMT). No. of bitstreams: 1 468625 - Texto Completo.pdf: 2863238 bytes, checksum: 3e057c78a6b6e5cfbd0cf6767d59dd26 (MD5) Previous issue date: 2014-03-26 / The clinical success of the implant treatment is strongly related with the achievement and maintenance of the stability of the fixture. As the surface topography, roughness and wettability are modifications that can affect the quality of the osseointegration, several studies have analyzed the benefits of these modifications. The histomorphometric analyses of the bone-to-implant contact (BIC) and the resonance frequency analyses (RFA) are commonly used to verify the osseointegration and implant stability. In the present study, 32 implants with two different surfaces treatment were installed in the tibia of 16 New Zealand rabbits and splitted in two groups. The Group I was formed by Neodent Drive implants, with sandblasted, acid etched and hydrophilic surface (Neodent Drive Acqua, Neodent, Curitiba, Brasil). The Group II was formed by Neodent Drive implants, with sandblasted and acid etched surface (Neodent Drive Porous, Neodent, Curitiba, Brasil). The samples were analyzed at 07, 14, 30 and 60 days after the implant placement. The results showed statistically significant differences between the mean values for the BIC at 14 (p=0.028) and 30 days (p=0.028). The mean BIC for the Acqua implants (Group I) were 43,32 ? 1,31% and 55,03 ? 5,14%, at 14 and 30 days respectively. The mean BIC in the Porous implants (Group II) were 46,27 ? 0,10% and 47,13 ? 0,67%, at 14 and 30 days, respectively. At 60 days, the mean BIC for the Acqua implants were 54,68 ? 3,51% and for the Porous implants were 50,86 ? 1,03%. There were not statistically significant differences in the implant stability quotient (ISQ) measurements between Acqua and Porous implants, except at 07 days after the implant placement. At day 07, the results of the present study showed higher ISQ values for the Porous implants (68,75 ? 4,16%) than Acqua implants (61,5 ? 8,01%). The follow-up ISQ analyses in the same Group, showed statistically significant increases of the mean values from 7 to 60 days and from 30 to 60 days, for both groups. In conclusion, the sandblasted and acid etched treatment used to create roughness on the Neodent implant surface is reliable and allows bone apposition, as the BIC and ISQ values found were similar or superior than the showed in the literature for similar animal models and similar implant surface. The increase of the BIC and ISQ values on the follow up showed the achievement of the secondary stability and the increase in stiffness between the implant fixture and the surrounding tissues. There were not identified better results with the hydrophilic surface during the early period of healing. Thus, further investigations are necessary to confirm the suggested results in this present study. / A obten??o e a manuten??o da estabilidade do implante s?o pr?-requisitos para o sucesso cl?nico das pr?teses sobre implantes. Visto que a topografia, a rugosidade e a hidrofilicidade s?o algumas das altera??es da superf?cie dos implante que podem alterar a resposta do tecido ?sseo, diversos estudos tem procurado entender os benef?cios que estas modifica??es podem proporcionar. A quantifica??o histomorfom?trica do contato osso-implante (BIC) e a an?lise de frequ?ncia de resson?ncia (AFR) s?o par?metros frequentemente utilizados na implantodontia para verificar a osseointegra??o e a estabilidade dos implantes. No presente estudo, foram instalados 32 implantes com duas diferentes superf?cies nas t?bias de 16 coelhos, divididos em dois grupos: Grupo I) constitu?do pelos implantes com superf?cie tratada por jateamento de areia, ataque ?cido, hidrof?lica e modificada quimicamente (Neodent Drive? Acqua, Neodent, Curitiba, Brasil) e Grupo II) constitu?do pelos implantes com superf?cie tratada por jateamento de areia e ataque ?cido (Neodent Drive? Porous, Neodent, Curitiba, Brasil). As amostras foram analisadas ap?s 7, 14, 30 e 60 dias da coloca??o dos implantes. Na compara??o da m?dia geral do BIC, entre Acqua e Porous, foram observadas diferen?as estatisticamente significantes no per?odo de 14 dias (p=0,028) e no per?odo de 30 dias (p=0,028). As medidas m?dias de BIC obtidas para os implantes Acqua foram 43,32 ? 1,31% e 55,03 ? 5,14%, aos 14 e 30 dias respectivamente. Para os implantes Porous, as medidas de BIC foram 46,27 ? 0,10% e 47,13 ? 0,67%, aos 14 e 30 dias respectivamente. No per?odo de 60 dias, os valores m?dios de BIC da superf?cie Acqua foram 54,68 ? 3,51% e da superf?cie Porous foram 50,86 ? 1,03%. Na compara??o da m?dia geral do quociente de estabilidade do implante (QEI), entre Acqua e Porous, n?o foram observadas diferen?as estatisticamente significantes entre os grupos, com exce??o no per?odo de 07 dias, no qual os resultados do presente estudo demonstraram maiores valores de QEI para o grupo Porous (68,75 ? 4,16%) do que para o grupo Acqua (61,5 ? 8,01%). A an?lise do QEI durante os diferentes per?odos dentro de um mesmo grupo, demonstrou diferen?as estatisticamente significativas entre os per?odos de 7 vs 60 dias e 30 vs 60 dias, para a m?dia geral do QEI no grupo Acqua e no grupo dos implantes Porous. As conclus?es do presente estudo s?o que os resultados demonstraram que a modifica??o da superf?cie por jateamento de areia e ataque ?cido utilizada para produzir as superf?cies Acqua e Porous resulta em uma adequada aposi??o ?ssea, visto que os valores do BIC e QEI encontrados s?o similares ou superiores aos resultados encontrados na literatura com modelos experimentais e superf?cies similares. Os aumentos dos valores do BIC e QEI durante os per?odos p?s-operat?rios revelaram a obten??o de estabilidade secund?ria e maior rigidez na ancoragem do implante com o passar do tempo. N?o foram identificados melhores resultados com a superf?cie hidrof?lica nos per?odos iniciais da osseointegra??o. Sendo assim, s?o necess?rios estudos pr?-cl?nicos e cl?nicos para confirmar as sugest?es que os resultados deste presente estudo revelaram.
133

A influ?ncia de implantes dent?rios em imagens de radiografia periapical, panor?mica e tomografia computadorizada de feixe c?nico

Felix, Rafael Perdomo 30 March 2015 (has links)
Submitted by Setor de Tratamento da Informa??o - BC/PUCRS (tede2@pucrs.br) on 2015-05-21T20:19:16Z No. of bitstreams: 1 469176 - Texto Completo.pdf: 1075538 bytes, checksum: c372985d28935427b18fce7ee072399d (MD5) / Made available in DSpace on 2015-05-21T20:19:16Z (GMT). No. of bitstreams: 1 469176 - Texto Completo.pdf: 1075538 bytes, checksum: c372985d28935427b18fce7ee072399d (MD5) Previous issue date: 2015-03-30 / Imaging exams performed in areas with the presence of metallic materials such as dental implants can decrease the accuracy of the exams due to metallic artifacts production generated in the peri-implant region. A sample of 21 dental implants placed in 10 patients with Branemark protocol prostheses was evaluated in the periimplant area in image exams of the post-surgery control using periapical radiography (paralleling technique), panoramic radiography and cone-beam computed tomography (CBCT). The radiographic density of different areas bounded near the dental implants were calculated and compared considering their locations and the imaging exams using the software ImageJ. Regarding the different imaging exams, the CBCT showed significant differences between the measured areas (p<0.001), while in periapical (p=0.430) and panoramic (p=0.149) radiographs did not occur significant difference between the gray mean values in these areas. Comparing the areas in the three exams it was observed larger values next to the implants in all exams: CBCT (126.20 and 127.44) panoramic radiography (106.51 and 106.09) and periapical radiography (120.32). The more distant areas and the areas closest to neighboring implants had significant different values in the two reconstructed images of CBCT when compared to the panoramic and periapical radiographs. The interference of dental implants in acquiring radiographic and tomographic exams was confirmed by altered radiographic density mean values in the peri-implant area. Comparing the three exams it was noticed that the CBCT image showed the most significant interference of the dental implants. / Os exames por imagem realizados em ?reas que apresentam materiais met?licos, como implantes dent?rios, podem ter sua qualidade prejudicada devido ? produ??o de artefatos met?licos gerados na regi?o peri-implantar. Uma amostra de 21 implantes dent?rios, em 10 pacientes com pr?teses do tipo protocolo Branemark, foi avaliada com o objetivo de comparar as densidades radiogr?ficas na regi?o periimplantar em exames de imagens de controle p?s-operat?rio com radiografia periapical (t?cnica do paralelismo), radiografia panor?mica e tomografia computadorizada de feixe c?nico. Os valores m?dios de densidade em ?reas delimitadas pr?ximas aos implantes dent?rios foram calculados e comparados, de acordo com suas localiza??es, e entre os exames de imagens utilizando o programa ImageJ. Os exames de Tomografia Computadorizada de Feixe C?nico (TCFC) apresentaram diferen?as significativas entre as ?reas medidas (p<0,001), enquanto que nas radiografias periapical (p=0,430) e panor?mica (p=0,149) n?o houve diferen?a significativa entre os valores m?dios de densidade nas mesmas ?reas. Na compara??o entre as ?reas dos tr?s exames, observou-se valores maiores naquelas pr?ximas aos implantes em todos os exames: TCFC (127,88 e 120,71), panor?mica (106,51 e 106,09) e periapical (120,32). As ?reas mais distantes e pr?ximas aos implantes vizinhos mostraram valores significativamente diferentes nos dois cortes da TCFC quando comparados aos exames periapical e panor?mico. Sendo assim, foi poss?vel confirmar a interfer?ncia dos implantes dent?rios na obten??o dos exames radiogr?ficos e tomogr?ficos, pela altera??o dos valores m?dios de densidade radiogr?fica na regi?o peri-implantar. Na compara??o entre os tr?s exames de imagem investigados, verificou-se que as imagens de TCFC sofreram a maior interfer?ncia dos implantes dent?rios, quando comparadas com as imagens radiogr?ficas.
134

Estudo da anatomia dental e configura??o dos canais radiculares por meio de tomografia computadorizada de feixe-c?nico

Wessel, Luiza 20 March 2015 (has links)
Submitted by Setor de Tratamento da Informa??o - BC/PUCRS (tede2@pucrs.br) on 2015-05-22T11:30:31Z No. of bitstreams: 1 469170 - Texto Completo.pdf: 2513966 bytes, checksum: a09f4f9fe263c78597980a0af648749f (MD5) / Made available in DSpace on 2015-05-22T11:30:31Z (GMT). No. of bitstreams: 1 469170 - Texto Completo.pdf: 2513966 bytes, checksum: a09f4f9fe263c78597980a0af648749f (MD5) Previous issue date: 2015-03-20 / Coordena??o de Aperfei?oamento de Pessoal de N?vel Superior - CAPES / Knowledge of internal dental anatomy is of fundamental importance to development and success of the endodontic treatment. Due to increasing population miscegenation and possibility of factors such as gender, age and ethnicity influence the anatomical configuration of root canals, this study aimed to assess the anatomical conformation of anterior inferiors teeth in computed tomography cone-beam images on the population of Porto Alegre, Rio Grande do Sul, Brazil. Images from 664 patients were analysed, in a total of 3,870 anterior inferiors teeth, seeking to quantify the number of roots of each element, classify the internal morphology according to Vertucci rating, check the gender and age influence in internal anatomy and determine the occurrence of anatomical bilateral asymmetry. Was identified a high incidence of two canals in central incisors (22.67%), in lateral incisors (27.48%) and canines (7.65%). All incisors had a single root and 3.29% of the canines had two roots. Relative to the symmetry of the conduits morphology, the canines had higher asymmetry when compared bilaterally (8.59%). It can be seen that the state's population has some anatomical differences in anterior inferiors teeth when compared to other populations previously studied. The CBCT is a useful tool to evaluate the root canal morphology and provides essential information to optimize the performance of endodontic treatment. / O conhecimento da anatomia dental interna ? de fundamental import?ncia para o desenvolvimento e sucesso do tratamento endod?ntico. Devido a crescente miscigena??o populacional e da possibilidade de fatores como sexo, idade, ra?a e etnia influenciarem na configura??o anat?mica dos canais radiculares, este estudo teve por objetivo, avaliar as conforma??es anat?micas de dentes anteroinferiores em imagens de tomografia computadorizada de feixe-c?nico na popula??o de Porto Alegre, Rio Grande do Sul, Brasil. Foram analisadas imagens de 664 pacientes, totalizando 3.870 dentes anteroinferiores, buscando quantificar o n?mero de ra?zes de cada elemento, classificar a morfologia interna de acordo com a classifica??o de Vertucci, verificar a influ?ncia do sexo e idade na anatomia interna e determinar a ocorr?ncia de assimetria anat?mica bilateral. Uma alta incid?ncia de dois canais foi identificada em incisivos centrais, 22,67%, nos incisivos laterais 27,48% e caninos 7,65%. Todos os incisivos apresentaram uma raiz e 3,29% dos caninos apresentaram duas ra?zes. Com rela??o ? simetria da morfologia dos condutos, os caninos apresentaram maior assimetria quando comparados bilateralmente, 8,59%. Pode-se verificar que a popula??o ga?cha apresenta algumas diferen?as anat?micas nos dentes anteroinferiores quando comparadas ?s demais popula??es anteriormente estudadas. A TCFC ? uma ferramenta ?til para avaliar a morfologia do canal radicular e fornece informa??es essenciais para otimizar a realiza??o de tratamento endod?ntico.
135

Incorpora??o de ?xido de zinco ou extrato de pr?polis em um cimento de ion?mero de vidro modificado por resina : efeito nas propriedades mec?nicas e citotoxicidade

Scheid, Patr?cia Alves 28 August 2014 (has links)
Submitted by Setor de Tratamento da Informa??o - BC/PUCRS (tede2@pucrs.br) on 2015-08-17T20:23:24Z No. of bitstreams: 1 473528 - Texto Completo.pdf: 1665841 bytes, checksum: 1e03f16b78da931d0d71809bb313ee0d (MD5) / Made available in DSpace on 2015-08-17T20:23:24Z (GMT). No. of bitstreams: 1 473528 - Texto Completo.pdf: 1665841 bytes, checksum: 1e03f16b78da931d0d71809bb313ee0d (MD5) Previous issue date: 2014-08-28 / Resin-modified glass-ionomer cement (RMGIC) is mainly indicated as a liner or base in restorative materials. In deep dentinal cavities where there is not symptomatology, only partial dentine is removed in order to avoid the pulp exposure. Thus, the restorative material is very close to the pulp. The aim of this study was to evaluate the incorporation of zinc oxide or extract of propolis in a RMGIC, subsequently testing the mechanical properties and citotoxicity. For the control group, the RMGIC (Vitremer, 3M ESPE) was handled in its original formulation (G7). Zinc oxide was inserted to the powder of RMGIC in the following proportions: 10% (G1), 20% (G2) e 30% (G3), which were mixed with the original liquid of Vitremer. The extract of propolis was inserted to the liquid of Vitremer in the following proportions: 10% (G4), 20% (G5), 30% (G6), which were mixed with the original powder of Vitremer. Compressive strength, diametral tensile, microhardness and roughness were measured. The cytotoxity was evaluated by MTT assay and neutral red after 24 and 48 hours of exposition. Data were analyzed using the IBM SPSS 22. To verify normality and homogeneity, Shapiro-Wilk and Levene tests were used, respectively, with significance level of 5%. The roughness, microhardness and compressive strength were assessed by one-way ANOVA followed by a multiple-comparison Tukey post hoc test. The diametral tensile was assessed by one-way ANOVA followed by a multiple-comparison Games-Howell post hoc test. For cytotoxity tests, one-way ANOVA and Duncan post hoc test was used to identify intergroup differences. The level of significance was set at p < 0,05. No significant difference was observed in the compressive strength and diametral tensile amog groups in relation to control group (G7). Groups 2, 4 e 6 did not differ in microhardness to the control group (G7). In the roughness test, the group 6 presented the highest mean statistical difference from group 7. Experimental groups showed similar or highest values of cell viability when compared to the group 7 in MTT assay and neutral red tests. The addition of 10% and 20% of extract of propolis or zinc oxide do not interfere in the mechanical proprieties and cytotoxicity of RMGIC. / O cimento de ion?mero de vidro modificado por resina (CIVMR) tem como fun??o principal servir como liner ou base na presen?a de material restaurador ou at? mesmo como material restaurador. Em cavidades profundas com aus?ncia de sinais e sintomas de pulpite irrevers?vel, a dentina afetada por c?rie pode ser mantida a fim de evitar a exposi??o pulpar, permanecendo, assim, um material muito pr?ximo ? polpa. O objetivo deste estudo foi avaliar os efeitos da inclus?o de ?xido de zinco ou de extrato de pr?polis em um CIVMR nas propriedades mec?nicas e citotoxicidade. Para o grupo controle, o cimento de ion?mero de vidro modificado por resina (Vitremer, 3M ESPE) foi manipulado em sua formula??o original (G7). As modifica??es foram realizadas atrav?s da inclus?o de ?xido de zinco ao p? do CIVMR nas seguintes propor??es: 10% (G1), 20% (G2) e 30% (G3) com rela??o ao peso, sendo aglutinado com o l?quido original do material. O extrato de pr?polis foi inserido ao l?quido do Vitremer nas seguintes propor??es: 10% (G4), 20% (G5) e 30% (G6) com rela??o em volume, sendo aglutinado com o p? original do CIVMR. Para a an?lise das propriedades mec?nicas foram realizados os testes de resist?ncia ? tra??o diametral, resist?ncia ? compress?o, microdureza e rugosidade superficial, 24 horas ap?s a confec??o dos corpos de prova. Para a an?lise da citotoxicidade foram realizados os testes de MTT e vermelho neutro, sendo avaliados nos per?odos de 24 e 48 horas. Os dados obtidos foram analisados atrav?s do software IBM SPSS 22. A distribui??o de normalidade foi verificada atrav?s do teste de Shapiro-Wilk e a homogeneidade atrav?s do teste de Levene. Os testes de rugosidade, microdureza e compress?o foram submetidos a ANOVA de um fator e Tukey. O teste de tra??o diametral foi submetido aos testes de ANOVA ucelentem fator e de Games-Howell. Os testes de citotoxicidade foram submetidos aos testes de ANOVA de um fator e Duncan. Todos os testes foram realizados com n?vel de signific?ncia de 5%, considerando p < 0,05. N?o foi registrada diferen?a estat?stica entre os grupos testados nos testes de resist?ncia a compress?o e tra??o diametral com rela??o ao grupo controle (G7). Na microdureza, os grupos 2, 4 e 6 n?o diferiram estatisticamente do grupo 7. Com rela??o ? rugosidade, apenas o grupo 6 apresentou m?dia superior ao G7. Nos testes de MTT e vermelho neutro, todos os grupos mostraram valores similares ou superiores ao grupo 7. A adi??o de extrato de pr?polis ou ?xido de zinco n?o interfere nas propriedades mec?nicas e na citotoxicidade do CIVMR nas concentra??es de at? 20%.
136

Influ?ncia da normaliza??o dos n?veis de cinza em tomografias computadorizadas Cone Beam e multislice na avalia??o da qualidade ?ssea

Schneider, Danilo Renato 12 January 2015 (has links)
Submitted by Setor de Tratamento da Informa??o - BC/PUCRS (tede2@pucrs.br) on 2015-09-04T19:09:27Z No. of bitstreams: 1 474617 - Texto Completo.pdf: 1140625 bytes, checksum: 1e763d7b5cf7e0a7ceeb1f2842c8c315 (MD5) / Made available in DSpace on 2015-09-04T19:09:28Z (GMT). No. of bitstreams: 1 474617 - Texto Completo.pdf: 1140625 bytes, checksum: 1e763d7b5cf7e0a7ceeb1f2842c8c315 (MD5) Previous issue date: 2015-01-12 / Coordena??o de Aperfei?oamento de Pessoal de N?vel Superior - CAPES / This paper aims to investigate the influence of normalization in cone beam computed tomography (CBCT) and multislice computed tomography (MSCT) grey level to assess bone quality of recipient sites for dental implants. DICOM (Digital Imaging and Communications in Medicine) images from 37 bone sites (18 patients) were analyzed. CBCT was performed with 5 different CBCT devices and MSCT in a single multislice CT scanner. Measurements of mean grey level were performed in two regions of interest; ROI1 - alveolar bone (cortical and trabecular) and ROI2 - cancellous bone separately with 3 tested forms: no normalization (RAW), normalization of the whole image (ALL) and normalization of the region of interest only (ROI). Descriptive analysis with coefficient of variation (CV) and one-way ANOVA followed by Tukey was performed. For MSCT, ROI1 mean grey level slightly increased from 121.9+-17.13 (RAW) to 125.0+-15.74 (ALL) (p>0.05) and reduced to 104.8+-15.20 (ROI) (p<0.0001). CV varied from 14.05%, to 12.59% and 14.50%, respectively. ROI2 increased from 95.11+-13.96 (RAW) to 99.40+-13.62 (ALL) and 102.5+-17.86 (ROI) (p=0.0678). CV was 14.67% to 13.71% and 17.43%, respectively. In CBCT group, ROI1 meaningfully raise from 91.73+-32.17 (RAW) to 135.2+-36.06 (ALL) and 118.7+-18.65 (ROI) (p<0.0001), with CV decreasing from 35.06% to 26.68% and 15.71%, respectively. ROI2 was 81.23+-34.36, 115.3+-28.53 and 109.4+-17.47, respectively (p=0.0002), with a CV reducing from 42.30% (RAW) to 24.74% (ALL) and 15.97% (ROI). Therefore, the use of intensity normalization of CBCT and MSCT examinations was demonstrated on reducing discrepancies between different scanners and inter-exams variability in bone quality assessment for dental implants. / Este trabalho objetiva investigar a influ?ncia da normaliza??o dos n?veis de cinza em tomografias cone beam (CBCT) e multislice (MSCT). Imagens DICOM (Digital Imaging and Communications in Medicine) de 37 s?tios ?sseos (18 pacientes) foram analisadas. As tomografias CBCT foram realizadas em 5 diferentes aparelhos e as tomografias MSCT foram obtidas em um ?nico tom?grafo. As medi??es dos n?veis de cinza foram feitas em duas regi?es de interesse; ROI1 - osso alveolar (cortical e medular) e ROI2 - osso medular separadamente, de 3 formas distintas: sem normaliza??o (RAW), normaliza??o de toda a imagem (ALL) e normaliza??o da regi?o de interesse apenas (ROI). An?lise descritiva com coeficiente de varia??o (CV) e teste ANOVA seguido de Tukey foi realizado. Para as MSCT, a m?dia dos n?veis de cinza da ROI1 aumentaram levemente de 121,9+-17,13 (RAW) para 125,0+-15,74 (ALL) (p>0,05) e reduziram para 104,8+-15,20 (ROI) (p<0,0001). O CV variou de 14,05%, para 12,59% and 14,50%, respectivamente. Na ROI2 a m?dia aumentou de 95,11+-13,96 (RAW) para 99,40+-13,62 (ALL) e 102,5+-17,86 (ROI) (p=0,0678). O CV foi de 14,67% para 13,71% e 17,43%, respectivamente. No grupo CBCT, a m?dia de ROI1 aumentou significativamente de 91,73+-32,17 (RAW) para 135,2+-36,06 (ALL) e 118,7+-18,65 (ROI) (p<0,0001), com o CV diminuindo de 35,06% para 26,68% e 15,71%, respectivamente. A m?dia da ROI2 foi 81,23+-34,36, 115,3+-28,53 and 109,4+-17,47, respectivamente (p=0,0002), com um CV reduzindo de 42,30% (RAW) para 24,74% (ALL) e 15,97% (ROI). Desta forma, foi demonstrada a redu??o das discrep?ncias entre diferentes aparelhos e da variabilidade entre exames com a utiliza??o da normaliza??o de intensidade de exames CBCT e MSCT na avalia??o da qualidade ?ssea para implantes dentais.
137

An?lise da citotoxicidade de comp?sitos restauradores para t?cnica direta e indireta : estudo in vitro

Mildner, Mariele Din? 24 March 2015 (has links)
Submitted by Setor de Tratamento da Informa??o - BC/PUCRS (tede2@pucrs.br) on 2015-09-04T19:35:28Z No. of bitstreams: 1 474592 - Texto Completo.pdf: 757600 bytes, checksum: b10e64c161ec1e67c4e8d9aa24a580ae (MD5) / Made available in DSpace on 2015-09-04T19:35:28Z (GMT). No. of bitstreams: 1 474592 - Texto Completo.pdf: 757600 bytes, checksum: b10e64c161ec1e67c4e8d9aa24a580ae (MD5) Previous issue date: 2015-03-24 / Coordena??o de Aperfei?oamento de Pessoal de N?vel Superior - CAPES / An appropriate monomer conversion of composite resins is very important to improve your biocompatibility. The aim of this study was to evaluate additional polymerization methods of dental resins cytotoxicity. A total of 72 samples were prepared from the following materials: Filtek Z350XT? (3M/ESPE, St Paul, MN, EUA), Sinfony (3M/ESPE, St Paul, MN, EUA), Lava Ultimate (3M/ESPE, St Paul, MN, EUA). The used color was A2 for all composite resins. To Filtek Z350XT and Sinfony a Teflon mould (3x2mm) was used. From Lava Ultimate block 1,6mm cubes was cutting with diamond discs and digital pachymeter. Samples was divided in 4 groups: FK Group: 20s LED polymerization, S Group: Sinfony with light and vacuum additional polymerization, L Group: Lava Ultimate, FPA Group: Filtek Z350XT with light and vacuum additional polymerization. Evaluate specimens was stored in DMEM medium for 24, 48 and 72 hours respectively. Thereafter, culture medium was in contact with NIH/3T3 fibroblasts. MTT test determined cellular viability. Statistical analysis realized by Levene and Kolmogorov-Smirnov tests (?=0,05). The S group show the lower cytotoxicity. Additional polymerization of FK group wasn?t efficient to cellular viability. Sinfony presented minor cytotoxicity among all tested materials. Light and vacuum additional polymerization of Filtek Z350XT don?t improve your cytotoxicity results when compared with direct polymerization of the same dental composite. / Um satisfat?rio grau de convers?o do mon?mero ? importante para melhorar a biocompatibilidade das resinas compostas. O objetivo deste estudo foi avaliar o efeito dos m?todos de polimeriza??o adicional na citotoxicidade de diferentes comp?sitos restauradores. Para isso foram confeccionadas 18 amostras de cada uma das seguintes resinas testadas: Filtek Z350XT? (3M/ESPE, St Paul, MN, EUA), Sinfony (3M/ESPE, St Paul, MN, EUA), Lava Ultimate (3M/ESPE, St Paul, MN, EUA). A cor usada em todas as reinas foi a A2 de corpo. Para as resinas Filtek Z350XT e Sinfony utilizaram-se moldes de politetrafluoretileno de 3x2mm. Para a resina Lava Ultimate foram cortados do bloco cubos com 1,6mm de face usando um disco diamantado e paqu?metro digital. As amostras foram divididas em 4 grupos: Grupo FK: Filtek Z350XT polimerizada por 20s com LED, Grupo S: Sinfony com polimeriza??o adicional com luz e v?cuo, Grupo L: Lava Ultimate, Grupo FPA: Filtek Z350XT com polimeriza??o adicional com luz e v?cuo. As esp?cies avaliadas estiveram em contato com meio DMEM por um per?odo de incuba??o de 24, 48 e 72 horas respectivamente. Ap?s, o meio de cultura foi colocado em contato com as c?lulas de fibroblastos NIH/3T3. Teste de MTT foi realizado para an?lise da viabilidade celular. Testes de Levene e Kolmogorov-Smirnov (?=0,05) foram utilizados para an?lise estat?stica. O grupo S apresentou-se com a citotoxicidade mais baixa. J? a polimeriza??o adicional no grupo FK n?o mostrou-se eficiente para a viabilidade celular. A resina Sinfony apresentou a menor citotoxicidade dentre os tr?s materiais analisados. Uma polimeriza??o adicional por luz e v?cuo na resina Filtek Z350XT n?o melhora seu resultado para citotoxicidade quando comparado a polimeriza??o direta da mesma.
138

Efeito biol?gico do Biodentine? e do MTA sobre exposi??o de tecido pulpar e periodontal da furca : estudo em ratos / Biological effect of Biodentine? and MTA on rats? dental pulp and furcal periodontal tissues

Reis, Magda de Sousa 15 October 2015 (has links)
Submitted by Setor de Tratamento da Informa??o - BC/PUCRS (tede2@pucrs.br) on 2016-02-12T17:20:18Z No. of bitstreams: 1 TES_MAGDA_DE_SOUSA_REIS_COMPLETO.pdf: 2952696 bytes, checksum: 9a8e4368b83491c5888a26990b0c9ddc (MD5) / Made available in DSpace on 2016-02-12T17:20:18Z (GMT). No. of bitstreams: 1 TES_MAGDA_DE_SOUSA_REIS_COMPLETO.pdf: 2952696 bytes, checksum: 9a8e4368b83491c5888a26990b0c9ddc (MD5) Previous issue date: 2015-10-15 / The aim of this study was to evaluate dental pulp and furcal periodontal tissue responses to mineral trioxide aggregate (MTA) and to a calcium silicate-based material (Biodentine?). The lower first molars in hundred forty (140) male Wistar rats were divided into groups according to the experimental site and period (14 and 21 days) testing two materials (n=8 per group/period in pulpotomy and n=6 per group/period in furcal perforation). Groups capped and sealed with MTA or Biodentine? were restored with silver amalgam; in an additional test group, teeth were capped and restored with Biodentine?. Teeth capped with gutta-percha and restored with silver amalgam served as a positive control and untouched teeth were negative control. Histological evaluation of pulp responses and macroscopic examination of coronal sealing were performed. Inflammation extension and intensity, degenerative events and formation of mineralized tissue barrier were assessed. In the experiment of furcal perforations, inflammation extension and intensity, bone resorption and cement formation were assessed histologically. All results underwent ANOVA and Tukey post hoc tests (p<.05). In pulpotomy, Biodentine? and MTA presented satisfactory results, which were characterized by a mild inflammatory response (p<.0001) and more pronounced formation of mineralized barrier (p<.0001) compared to teeth capped with gutta-percha. When used as a restorative material, Biodentine? kept coronal sealing in only 37.5% of the samples. As to furcal perforations, Biodentine? and MTA presented satisfactory results, which were characterized by a milder inflammatory response compared to the control, regardless of the material used for coronal sealing and of the experimental period evaluated (p<.0001). All test groups showed less bone resorption than the positive control after 21 days (p<.05), being this difference more pronounced in teeth restored with silver amalgam. Cement repair occurred in 30% of MTA and Biodentine? samples, and was not detected in any specimen of the positive control group. In conclusion, Biodentine? and MTA promoted similar responses when used to pulp capping and furcal perforation sealing. On the other hand, the use of Biodentine? as temporary restorative material did not promote efficient coronal sealing. Although further investigations are required, Biodentine? can be considered an alternative for pulpotomy and furcal perfuration. / O objetivo deste estudo foi comparar a resposta tecidual, ap?s pulpotomias e perfura??es de furca, utilizando agregado tri?xido de mineral (MTA) e o material ? base de silicato tric?lcico (Biodentine?). Os primeiros molares inferiores de 140 ratos Wistar machos foram utilizados em dois tempos (14 e 21 dias) e divididos em grupos conforme o experimento e materiais utilizados (pulpotomia n=8 e perfura??o de furca n=6). Nos dois experimentos, grupos capeados e selados com MTA e Biodentine? foram restaurados com am?lgama de prata; um grupo adicional utilizou somente Biodentine? e o controle positivo recebeu guta-percha e restaura??o de am?lgama; dentes intactos serviram de controle negativo. No experimento de pulpotomias, realizou-se exame macrosc?pico e radiogr?fico do selamento coron?rio e exame histol?gico dos eventos inflamat?rios (intensidade e extens?o), degenerativos e de forma??o de barreira mineralizada. No experimento de perfura??es de furca, foram avaliados histologicamente os eventos inflamat?rios (intensidade e extens?o), de reabsor??o ?ssea e reparo de cemento. Os dados foram comparados atrav?s da an?lise de vari?ncia (ANOVA) e posthoc de Tukey (p<.05). Nas pulpotomias, o Biodentine? e MTA apresentaram resultados satisfat?rios, com menor resposta inflamat?ria (p<.0001) e pronunciada forma??o de barreira mineralizada (p<.0001) comparada aos dentes do controle positivo. O Biodentine?, utilizado como restaura??o, manteve o selamento coron?rio em apenas 37.5% das amostras. Nas perfura??es de furca, o Biodentine e MTA apresentaram resultados satisfat?rios, caracterizados por uma resposta inflamat?ria mais suave em compara??o ao controle positivo, independentemente do material utilizado para o selamento coron?rio e per?odo experimental avaliado (p<.0001). Todos os grupos testes mostraram menor reabsor??o ?ssea do que o controle positivo ap?s 21 dias (p<.05), sendo esta diferen?a mais acentuada em dentes restaurados com am?lgama de prata. A repara??o de cemento ocorreu em 30% das amostras de MTA e Biodentine, e n?o foi detectada em qualquer amostra do grupo do controle positivo. Concluiu-se que houve respostas similares ap?s o uso de Biodentine? e MTA no capeamento da polpa exposta e selamento de perfura??es de furca. Por outro lado, o uso do Biodentine? como material restaurador provis?rio n?o promoveu selamento coron?rio eficiente. Embora sejam necess?rias novas investiga??es, o Biodentine deve ser considerado como uma alternativa frente aos tratamentos propostos.
139

Protocolo de preserva??o ?ssea para avalia??o de tecido ?sseo e osseointegra??o de implantes de tit?nio

Kunrath, Marcel Ferreira 12 January 2016 (has links)
Submitted by Setor de Tratamento da Informa??o - BC/PUCRS (tede2@pucrs.br) on 2016-04-06T11:40:47Z No. of bitstreams: 1 DIS_MARCEL_FERREIRA_KUNRATH_COMPLETO.pdf: 1943048 bytes, checksum: f2472fa9da9d6ca1d610f11f2d69bc64 (MD5) / Made available in DSpace on 2016-04-06T11:40:47Z (GMT). No. of bitstreams: 1 DIS_MARCEL_FERREIRA_KUNRATH_COMPLETO.pdf: 1943048 bytes, checksum: f2472fa9da9d6ca1d610f11f2d69bc64 (MD5) Previous issue date: 2016-01-12 / With the growing expansion of implant surfaces and the need for greater speed of osseointegration, methods of analysis of bone tissue and implant surface as well as the quality of the bone implant contact (BIC), they are increasingly being explored by researchers. The aim of this study is to show detail and describe a bone preservation protocol for making implants samples with and without implants without any harm or damage, or the bone tissue or the properties of the metal, preserving the BIC. In a second step, the samples prepared by the protocol preservation were compared with those made by histological analysis method for staining for HE, considered the gold standard for living tissue. Eight samples were used for bone tissue with implants in rabbit tibia and more four fragments of jaws without implants of the same rabbits. Samples with and without implants were made by the two protocols, after preparation of the test specimens, analysis by optical microscopy of transmission and reflection through scanned images were made. Each protocol had advantages when the results were analyzed individually in the implants without samples, becoming further analysis. However, for samples with implants, analysis only by histological method cannot bring good results, while the bone preservation method showed excellent results for osseointegration analysis, bone formation and bone implant interface. It follows that the bone preservation protocol is an excellent method for analyzing samples with implants, and can be complementary to histology, in analysis bone samples without implants. The histological method is not sufficient for analysis of bone formation and bone implant interface. / Com a crescente expans?o de superf?cies de implantes e a necessidade de maior velocidade de osseointegra??o, m?todos de an?lise do tecido ?sseo, an?lises da superf?cie de implantes e a qualidade do contato osso-implante (BIC) est?o cada vez mais sendo explorados pelos pesquisadores. O objetivo do presente estudo foi descrever detalhadamente um protocolo de preserva??o ?ssea para confec??o de amostras com e sem implantes, sem causar danos ou avarias nem ao tecido ?sseo nem ?s propriedades do metal, preservando o BIC. Em uma segunda etapa, as amostras confeccionadas pelo protocolo de preserva??o ?ssea foram comparadas com as amostras preparadas pelo m?todo de an?lise histol?gica por colora??o por Hematoxilina-Eosina, considerado padr?o ouro para tecidos vivos. Foram utilizadas oito amostras de tecido ?sseo com implantes de t?bias de coelhos e, mais quatro fragmentos de mand?bulas sem implantes, dos mesmos coelhos. As amostras com e sem implantes foram confeccionadas pelos dois protocolos e, ap?s a prepara??o dos corpos de prova, foram feitas as an?lises por microscopia ?ptica de transmiss?o e reflex?o atrav?s de imagens digitalizadas. Cada protocolo apresentou vantagens quando os resultados foram analisados individualmente nas amostras sem implantes. Por?m, para as amostras com implantes, a an?lise apenas pelo m?todo histol?gico n?o conseguiu apresentar bons resultados, enquanto que o m?todo de preserva??o ?ssea mostrou excelentes resultados para an?lise de osseointegra??o, neoforma??o ?ssea e interface osso-implante. Conclui-se que o protocolo de preserva??o ?ssea desenvolvido mostrou-se um excelente m?todo para an?lise de amostras com implantes, e que pode ser complementar ? histologia, em an?lises de tecido ?sseo sem implantes. O m?todo histol?gico n?o mostrou-se suficiente para an?lise de neoforma??o ?ssea e interface osso-implante.
140

Avalia??o da adapta??o e da microinfiltra??o marginal de uma resina composta de incremento ?nico frente a diferentes t?cnicas de fotoativa??o

Gamarra, Vania Stephanie S?nchez 25 January 2016 (has links)
Submitted by Setor de Tratamento da Informa??o - BC/PUCRS (tede2@pucrs.br) on 2016-04-12T14:08:12Z No. of bitstreams: 1 DIS_VANIA_STEPHANIE_SANCHEZ_GAMARRA_PARCIAL.pdf: 192614 bytes, checksum: ac0bcd8326b2183c17301f29601b81ee (MD5) / Made available in DSpace on 2016-04-12T14:08:12Z (GMT). No. of bitstreams: 1 DIS_VANIA_STEPHANIE_SANCHEZ_GAMARRA_PARCIAL.pdf: 192614 bytes, checksum: ac0bcd8326b2183c17301f29601b81ee (MD5) Previous issue date: 2016-01-25 / Conselho Nacional de Pesquisa e Desenvolvimento Cient?fico e Tecnol?gico - CNPq / The aim of this study was to evaluate, in vitro, the marginal adaptation and microleakage of class II restorations of SonicFill composite resin with different curing techniques. Class II preparations were prepared in 40 human premolars (mesial margin 1 mm below the CEJ, distal margin 1 mm above the CEJ), and randomly divided into 4 groups according to curing technique (n = 10 per group): G1: 1200 mW/cm2 for 20 s; G2: 1200 mW/cm2 for 40 s; G3: Soft-start for 20 s (650 mW/cm2 for 5 s, increasing to 1200 mW/cm2 for 15 s); G4: Soft-start for 40 s (650 mW/cm2 for 10 s, increasing to 1200 mW/cm2 for 30 s). Three-step etch&rinse adhesive Optibond FL was applied and the cavity was filled in bulk with SonicFill composite resin, followed by oclusal sculpture and photoactivation. Impressions were made using polyvinyl siloxane and epoxy resin replicas were obtained, before and after thermocycling. The occlusal and cervical margins were analyzed with SEM at 200x magnification. The marginal adaptation was expressed as percentages of continuous margins. After thermocycled, the specimens were immersed in silver nitrate 50%, and analyzed the extention of dye penetration in the cervical-mesial and cervical-distal margins. According to ANOVA and Tukey?s test, there was statistical difference in the percentage of continuous margins on the occlusal-palatine for group 1 (83.19%), differing statistically from groups 2, 3 and 4 that had values over 95% for continuous margins (p?0,05). In the cervical margin there was no statistical difference between the groups (p?0,05). According to Student's t test, after thermocycling, there was a statistical significant reduction of percentage of continuous margins in occlusal-buccal margin for groups 1, 2 and 4, as well as in the cervical-mesial margin for groups 1, 3 and 4, and cervical-distal margin only to group 1. According to Kruskal-Wallis test, there was no significant difference in the microleakage scores between groups in the enamel (p=0.373) and in dentin (p=0.561), being predominantly score 1 in enamel and score 3 in dentin. The bulk filling technique with SonicFill composite resin associated with three-step etch&rinse adhesive Optibond FL in class II cavities provided gap formation and microleakage, especially in the cervical dentin region, regardless of the curing technique. / O objetivo do estudo foi avaliar, in vitro, a adapta??o e o selamento marginal de restaura??es classe II em resina composta SonicFill com diferentes t?cnicas de fotoativa??o. Foram realizados preparos classe II em 40 pr?-molares humanos (caixa mesial 1 mm abaixo da JCE, caixa distal 1 mm acima JCE), sendo divididos aleatoriamente em 4 grupos de acordo com a t?cnica de fotoativa??o (n = 10 por grupo): G1: 1200 mW/cm2 por 20 s; G2: 1200 mW/cm2 por 40 s; G3: Soft-start por 20 s (650 mW/cm2 por 5 s, elevando para 1200 mW/cm2 por 15 s); G4: Soft-start por 40 s (650 mW/cm2 por 10 s, elevando para 1200 mW/cm2 por 30 s). O sistema adesivo Optibond FL foi aplicado e a cavidade foi preenchida em incremento ?nico com a resina composta SonicFill, seguido da escultura da oclusal e fotoativa??o. A partir de moldagens com silicone por adi??o, foram obtidas r?plicas em resina ep?xica das restaura??es antes e ap?s termociclagem. As margens das r?plicas, ao n?vel oclusal e cervical, foram analisadas no MEV em 200x, sendo determinada a porcentagem de margens continuas. Ap?s termociclagem, os corpos de prova foram submetidos ? metodologia de microinfiltra??o com nitrato de prata a 50%, sendo analisada a extens?o da penetra??o na margem cervical mesial e distal. De acordo com ANOVA e teste de Tukey, houve diferen?a estat?stica na porcentagem de margens cont?nuas na oclusal-palatina para o grupo 1 (83,19%), diferindo estatisticamente dos grupos 2, 3 e 4 que tiveram valores acima de 95% para margens cont?nuas (p?0,05). Na margem cervical n?o houve diferen?a estat?stica entre os grupos (p?0,05). De acordo com o teste t-student, ap?s termociclagem, houve redu??o estatisticamente significativa na porcentagem de margens continuas na margem oclusal-vestibular para os grupos 1, 2 e 4, assim como na margem cervical-mesial para os grupos 1, 3 e 4, e na regi?o cervical-distal apenas para o grupo 1. De acordo com o teste de Kruskal-Wallis, n?o houve diferen?a significativa para os escores de microinfiltra??o entre os grupos, tanto no esmalte (p=0,373) como na dentina (p=0,561), sendo predominantemente escore 1 em esmalte e escore 3 em dentina. A t?cnica de incremento ?nico com a resina composta SonicFill, associada ao sistema adesivo Optibond FL, em cavidades classe II, proporcionou a forma??o de fendas e a ocorr?ncia de microinfiltra??o, principalmente na regi?o cervical com t?rmino em dentina, independente da t?cnica de fotoativa??o.

Page generated in 0.0374 seconds