• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 290
  • 20
  • 20
  • 2
  • 1
  • 1
  • Tagged with
  • 334
  • 260
  • 255
  • 229
  • 208
  • 153
  • 143
  • 119
  • 107
  • 72
  • 66
  • 58
  • 50
  • 47
  • 46
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
141

Constru??o de um biomodelo com interposi??o de placa oclusal para an?lise de tens?es nos discos articulares da ATM pelo m?todo dos elementos finitos

Silva, Carlos Augusto Gomes da 22 January 2016 (has links)
Submitted by Setor de Tratamento da Informa??o - BC/PUCRS (tede2@pucrs.br) on 2016-05-06T16:44:45Z No. of bitstreams: 1 DIS_CARLOS_AUGUSTO_GOMES_DA_SILVA_PARCIAL.pdf: 134804 bytes, checksum: 6d941459abeadf56a9fb5b1afbfe9927 (MD5) / Made available in DSpace on 2016-05-06T16:44:45Z (GMT). No. of bitstreams: 1 DIS_CARLOS_AUGUSTO_GOMES_DA_SILVA_PARCIAL.pdf: 134804 bytes, checksum: 6d941459abeadf56a9fb5b1afbfe9927 (MD5) Previous issue date: 2016-01-22 / Conselho Nacional de Pesquisa e Desenvolvimento Cient?fico e Tecnol?gico - CNPq / The aim of this study was to investigate the possibility of creating a three-dimensional model of the masticatory system of a patient for analysis in MEF. Also, to configure the parameters for the attainment of a clenching test with variations in intensities bite force with the interposition of two occlusal splints of different materials. Using the computed tomography (CT) and magnetic resonance imaging (MRI) of a patient, were built, through the process of reverse engineering, seven pieces to compose a biomodel. Four software was used throughout the process to achieve the desired result. Also, from this model was created finite element mesh of components and defined the boundary conditions. An occlusal splint was created and its physical and mechanical properties were switched to simulate the behavior of two different plates: a rigid and resilient. The model received force vectors that simulate the action of four pairs of muscles: temporal, masseter, medial pterygoid and lateral; and was assigned to these three distinct forces for each test: 25oN, 50oN and 75oN. According to what was found in this study it can be concluded that the construction of a biomodel from CT and MR images are completely feasible. In addition, the methodology used to obtain the models and the settings configured for the tests in MEF resulted in a good approach to clinical reality along the lines of current research. / O objetivo do presente estudo foi verificar a possibilidade da cria??o de um modelo tridimensional do sistema mastigat?rio de um paciente para an?lise em MEF. E tamb?m, configurar os par?metros para a realiza??o de um teste de apertamento dent?rio com varia??es nas intensidades de for?a de mordida com a interposi??o de duas placas oclusais de diferentes materiais. A partir dos exames de tomografia computadorizada (TC) e resson?ncia magn?tica (RM) de um paciente foram constru?dos, por meio de engenharia reversa, sete pe?as para compor um biomodelo. Quatro softwares foram usados em todo o processo at? atingir o resultado desejado. Ainda, a partir deste modelo foi criada a malha de elementos finitos dos componentes e definidas as condi??es de contorno. Uma placa oclusal foi criada e suas propriedades f?sicas e mec?nicas foram alternadas para simular o comportamento de duas placas distintas: uma r?gida e uma resiliente. O modelo recebeu vetores de for?a que simularam a a??o de quatro pares de m?sculos: temporal, mass?ter, pterigoideo medial e lateral; e foi atribu?do a estes, tr?s for?as distintas para cada teste: 25ON, 50oN e 75oN. De acordo com o que foi apurado neste estudo ? poss?vel concluir que a constru??o de um biomodelo a partir de imagens de TC e RM e plenamente vi?vel. Al?m disso, a metodologia adotada para obten??o dos modelos e as configura??es definidas para os testes em MEF resultaram em uma boa aproxima??o a realidade clinica seguindo a linha das pesquisas vigentes.
142

Compara??o in vitro da citotoxidade dos an?is ortod?nticos com e sem soldagem ? prata em diferentes linhagens celulares

Jacoby, Let?cia Spinelli 29 February 2016 (has links)
Submitted by Setor de Tratamento da Informa??o - BC/PUCRS (tede2@pucrs.br) on 2016-05-06T16:53:23Z No. of bitstreams: 1 DIS_LETICIA_SPINELLI_JACOBY_PARCIAL.pdf: 409701 bytes, checksum: ece1c9e62d9b0d680c9b4a7d64a27079 (MD5) / Made available in DSpace on 2016-05-06T16:53:23Z (GMT). No. of bitstreams: 1 DIS_LETICIA_SPINELLI_JACOBY_PARCIAL.pdf: 409701 bytes, checksum: ece1c9e62d9b0d680c9b4a7d64a27079 (MD5) Previous issue date: 2016-02-29 / Coordena??o de Aperfei?oamento de Pessoal de N?vel Superior - CAPES / Introduction: The aims of this study were to assess the in vitro cytotoxicity of orthodontic bands, with and without silver solder, and to compare the viability of the HaCaT, HGF, MRC-5, and Vero cell lines, when exposed to orthodontic band extracts. Material and Methods: An MTT assay was performed on the extracts of the tested materials. The culture medium alone was used as a negative control and copper strip extracts were used as a positive control. Results: A one-way Analysis of Variance (ANOVA) showed a difference between all of the groups in all of the cell lines and Tukey?s post-hoc test revealed no significant differences between the stainless steel orthodontic bands and the negative control group. There was a significant difference between the negative control group and the stainless steel orthodontic bands with silver solder joints in the HaCaT and MRC-5 cell lines. A great variability in the percentages of cell viability was observed. According to these results, the stainless steel orthodontic bands did not induce cytotoxic effects on any of the cell lines. When associated with silver solder, the orthodontic bands decreased the cell viability in the HaCaT, HGF, MRC-5, and Vero cell lines, but there was only a statistical significance in the HaCaT and MRC-5 cell lines. Conclusions: More than one type of cell line must be tested in a cytotoxicity assay due to the outcome variability from one cell line to another. / Introdu??o: Os objetivos deste estudo foram avaliar, in vitro, a citotoxicidade dos an?is ortod?nticos com e sem soldagem ? prata e comparar a viabilidade celular nas linhagens FGH, HaCaT, MRC-5 e Vero ap?s a exposi??o aos extratos dos an?is ortod?nticos. Materiais e M?todos: Foi realizado o ensaio de redu??o de MTT ap?s a exposi??o das culturas celulares aos extratos dos materiais testados. Foram utilizados como controles negativo e positivo, respectivamente, meio de cultura DMEM e extratos de tira de cobre. Resultados: A an?lise de vari?ncia de uma via (ANOVA) mostrou que houve diferen?a estatisticamente significativa entre os grupos em todas as linhagens avaliadas. O teste de compara??es m?ltiplas de Tukey detectou aus?ncia de diferen?a significativa entre os grupos controle negativo e an?is ortod?nticos de a?o inoxid?vel. Houve diferen?a estatisticamente significativa entre os grupos controle negativo e an?is ortod?nticos de a?o inoxid?vel com soldagem ? prata nas linhagens celulares HaCaT e MRC-5. Observou-se grande variabilidade nas percentagens de viabilidade celular entre as linhagens. Conclus?es: Ao avaliar a citotoxicidade de an?is ortod?nticos com e sem soldagem ? prata, existe variabilidade nos resultados quando linhagens diferentes s?o comparadas. An?is ortod?nticos de a?o inoxid?vel n?o induziram efeitos citot?xicos em nenhuma das linhagens testadas. Quando associados ? solda de prata, os extratos dos an?is ortod?nticos reduziram a viabilidade celular nas linhagens FGH, HaCaT, MRC-5 e Vero, embora essa redu??o tenha ocorrido de forma estatisticamente significativa apenas nas linhagens HaCaT e MRC-5.
143

An?lise por elementos finitos de nova proposta de dispositivo para redu??o e fixa??o das fraturas de c?ndilo mandibular

Conci, Ricardo Augusto 09 March 2016 (has links)
Submitted by Setor de Tratamento da Informa??o - BC/PUCRS (tede2@pucrs.br) on 2016-05-13T11:41:26Z No. of bitstreams: 1 TES_RICARDO_AUGUSTO_CONCI_COMPLETO.pdf: 49140416 bytes, checksum: d2aa3ccb467a7e2955c07d181b6496d8 (MD5) / Made available in DSpace on 2016-05-13T11:41:26Z (GMT). No. of bitstreams: 1 TES_RICARDO_AUGUSTO_CONCI_COMPLETO.pdf: 49140416 bytes, checksum: d2aa3ccb467a7e2955c07d181b6496d8 (MD5) Previous issue date: 2016-03-09 / Coordena??o de Aperfei?oamento de Pessoal de N?vel Superior - CAPES / The large incidence and the controversies related to the diagnose, forms of treatment, surgical accesses and osteosynthesis material types, determine that condylar fractures have a featured place among facial fractures. It is possible to perform a surgical or non surgical treatment depending on the endless situations and clinical indications. After choosing the surgical access, one should obtain an adequate reduction of the fractures and an effective internal fixation, respecting the anatomic characteristics of the condylar region, in order to obtain a satisfying funcional result. Plates configurations, isolated or not, with different shapes and sizes, can be used for a surgical solution to the condylar fractures. Aiming an enhancement of the advantages and decreasing of the disadvantages, regarding the fixation techniques, the screw Neck Screw was developed, with the purpose of creating the stabilization required to achieve a correct fixation through a dynamic compression system, increasing the contact between the fractured bone stubs, as well as serving as an ally when reducing the fractures. The present paper has as objective to evaluate the fixation and the stability of the jaw condyle fractures, and compare four fixation techniques: the first configuration presents a 2.0 mm plate, with four holes in it, the second one has two plates, one of 2.0 mm and the other with 1.5 mm, both with four holes in it and screws 6.0 mm long, the third fixation system has the Neck Screw and a ?L? shaped plate, with four holes, 2.0 mm wide, overlapped between them, and the last one has the Neck Screw and the ?L? shaped plate forming a single device, united through a solder. The results demonstrate a better stability when using two plates, regarding the dislocation of the fractures, synthesis materials deformation, minimal and maximal tension values. The results with the Neck Screw are satisfying, much as the ones found when using a mini plate, being, therefore, an alternative to the reduction and fixation of condylar fractures, if correctly indicated and with an adequate surgical sequence and technique. / A grande incid?ncia e as controv?rsias relacionadas ao diagn?stico, formas de tratamento, acessos cir?rgicos e tipos de materiais de osteoss?ntese, fazem com que as fraturas condilares tenham papel de destaque dentre as fraturas faciais. Pode-se realizar tratamento cir?rgico ou n?o-cir?rgico, dependendo de in?meras situa??es e indica??es cl?nicas. Quando escolhido o acesso cir?rgico, deve-se conseguir redu??o adequada das fraturas e fixa??o interna eficiente, respeitando as caracter?sticas anat?micas da regi?o condilar, para obten??o de um resultado funcional satisfat?rio. Configura??es de placas, isoladas ou n?o, com formatos e tamanhos diversos, podem ser utilizadas para a resolu??o cir?rgica das fraturas condilares. Visando aprimorar as vantagens e minimizar as desvantagens das t?cnicas de fixa??o, foi desenvolvido o parafuso Neck Screw, objetivando a estabilidade necess?ria para a correta fixa??o por meio de um sistema de compress?o din?mica, aumentando o contato entre os cotos ?sseos fraturados, al?m de servir como aliado no momento da redu??o das fraturas. O presente trabalho tem como objetivo avaliar a fixa??o e a estabilidade das fraturas de c?ndilo mandibular e comparar quatro t?cnicas de fixa??o, sendo que a primeira configura??o apresenta uma placa de 2.0 mm, com 4 furos, com parafusos de 6 mm de comprimento, a segunda configura??o apresenta duas placas, sendo uma de 2.0 mm e outra de 1.5 mm, ambas com 4 furos, com parafusos de 6 mm de comprimento, o terceiro sistema de fixa??o com o parafuso Neck Screw e uma placa em ?L? de 4 furos de 2.0 mm sobreposta, al?m do ?ltimo grupo, onde o parafuso Neck Screw e a placa em ?L? formam um dispositivo ?nico, atrav?s de jun??o por ponto de solda. Os resultados demonstram uma melhor estabilidade quando do uso de duas placas, no que diz respeito ao deslocamento das fraturas, deforma??o dos materiais de s?ntese e valores de tens?es m?nimas e m?ximas. Os resultados com o parafuso Neck Screw s?o satisfat?rios, semelhantes aos encontrados quando da utiliza??o de uma miniplaca, sendo, portanto, uma alternativa para redu??o e fixa??o das fraturas condilares, desde que corretamente indicado e com sequ?ncia e t?cnica cir?rgica adequadas.
144

Estudo de reparo por dupla calha em dutos rígidos com defeito tipo mossa com cava

Nunes, Cristian Duarte January 2017 (has links)
O reparo em dutos defeituosos é previsto por normas e literatura, porém existe grande espaço para definição dos parâmetros ideais para aplicação prática e avaliação do desempenho destes reparos em fadiga. O presente trabalho tem por objetivo a definição dos parâmetros ideais para aplicação de reparos eficientes do tipo dupla calha sem solda circunferencial e com carregamento externo em escala real em dutos com defeitos de mossa com cava. O reparo é baseado na instalação de duas calhas concêntricas ao duto a ser reparado, preenchendo-se o defeito com resina e aplicando carga de compressão através de atuadores hidráulicos com correntes a fim de induzir tensões compressivas na região do defeito e, por fim, as calhas são unidas longitudinalmente pelo processo de soldagem. Para este trabalho, foi realizada uma modelagem numérica utilizando o método de elementos finitos de modo a simular a reprodução do defeito, ensaios de fadiga sem reparo, parâmetros para aplicação do reparo, ensaios de fadiga com reparo e, por fim, ensaio hidrostático. O procedimento proposto foi a reprodução do defeito, primeiramente o duto foi deformado com uma esfera metálica, de modo a formar uma mossa de profundidade igual a 6 % do diâmetro externo e, em seguida, a cava foi usinada com a utilização de um disco abrasivo. Após a produção do defeito, três amostras foram ensaiadas em fadiga, de modo a produzir uma amostra de referência sem reparo a ser comparada com os corpos de prova com reparo. O reparo dupla calha foi aplicado em duas amostras com defeito, sendo essas então submetidas a ensaios de fadiga. Esses ensaios indicaram que ambas as amostras resistiram a um número de ciclos correspondentes a 100 anos de vida em serviço. Por fim, as amostras reparadas após o ensaio de fadiga foram submetidas a ensaios hidrostáticos até a ruptura, a fim de avaliar a vida remanescente. Ambos os dutos romperam fora da região reparada, com uma pressão 2,1 %, menor que a pressão calculada analiticamente. Como principal resultado, foram obtidos parâmetros ideais para aplicação do reparo dupla calha em dutos com defeito tipo mossa com cava. Os resultados experimentais mostram convergência em relação aos dados do modelo numérico, provando que a modelagem por elementos finitos pode ser uma ferramenta útil no desenvolvimento deste tipo de trabalho. / Defective duct repairs are envisaged by norms and by the literature, yet there is enough space left to define ideal parameters for practical application and performance evaluation of these fatigue repairs. This work’s objective is to define the ideal parameters for the application of efficient repairs in double spouts without circumferential welding and real scale external loading in ducts with dent and gouge defects. The repair is based on the installation of two concentric spouts in the duct, filling the defect with resin and applying compression loading through hydraulic actuators with currents to induce compressive stresses in the defective area. Afterwards, the spouts are united lengthwise through the process of welding. To develop this work, we conducted a numerical modelling by using the finite element method to simulate the reproduction of the defect, as well as fatigue tests with no repairs, parameters for the application of repairs, fatigue tests with repairs, and finally a hydrostatic test. The proposed procedure was the reproduction of the defect. At first the duct was deformed with a metallic sphere, to form a dent whose depth was equal to 6 % of the external diameter and, subsequently, the gouge was machined with the help of an abrasive disk. Following the production of a defect, three samples were tested in fatigue to produce a reference sample without repair which would be compared to the samples with repairs. The double spout repair was applied in two samples with defects, which were then subjected to fatigue tests. These tests showed that both samples resisted to a number of cycles corresponding to a 100-year use lifespan. At last, the samples repaired after fatigue tests were subjected to hydrostatic tests until rupture, in order to evaluate their remaining lifespan. Both ducts ruptured outside of the repaired region, with a stress rate of 2.1 %, lower than the stress calculated analytically. The main result of this study was obtaining ideal parameters for the application of double spout repair in ducts with dents and gouge defects. The experimental results show convergence in relation to the numerical model data, proving that finite element modelling can be a useful tool when conducting this kind of work.
145

Altera??es dent?rias e esquel?ticas decorrentes do tratamento da classe II, divis?o 1

Souza, Ma?ra Massuia de 13 December 2007 (has links)
Made available in DSpace on 2015-04-14T13:29:24Z (GMT). No. of bitstreams: 1 399334.pdf: 1695765 bytes, checksum: 6f59773029d40433eae27686ee2c6259 (MD5) Previous issue date: 2007-12-13 / O objetivo desse estudo foi avaliar os efeitos decorrentes do tratamento da Classe II, divis?o 1 sobre a maxila; a posi??o dos primeiros molares e dos incisivos centrais permanentes superiores; e a rela??o maxilo-mandibular. O grupo experimental foi composto por 38 pacientes brasileiros brancos (14 meninos e 24 meninas) com idade m?dia de 11 anos e 2 meses, no in?cio, e 14 anos e 5 meses, ao final do tratamento, realizado com arco extrabucal tra??o cervical associado ao aparelho fixo, em ambas as arcadas. O grupo controle foi composto por 39 indiv?duos canadenses (14 meninas e 25 meninos), participantes do Burlington Growth Study, Universidade de Toronto, Canad?, tratados somente por supervis?o e manuten??o de espa?os. Cada paciente do grupo experimental apresentava uma telerradiografia inicial (T1) e uma final (T2). Na amostra controle, telerradiografias seriadas obtidas aos 9, 12, 14 e 16 anos forneceram os dados para a compara??o com a amostra experimental. Na an?lise estat?stica, o teste t de Student proporcionou as compara??es entre os valores iniciais e finais dos grupos experimental e controle, bem como a compara??o entre as varia??es ocorridas em cada grupo. Os resultados indicaram que o tratamento realizado gerou restri??o do deslocamento anterior e giro hor?rio da maxila, em ambos os g?neros, provocou extrus?o dos primeiros molares e dos incisivos centrais permanentes superiores, nos pacientes do g?nero masculino, impediu a rota??o anti-hor?ria natural da mand?bula, principalmente no g?nero masculino e promoveu a melhora da rela??o maxilo-mandibular.
146

Retra??o de caninos superiores com br?quetes autoligados e convencionais

Mezomo, Maur?cio Barbieri 14 January 2009 (has links)
Made available in DSpace on 2015-04-14T13:29:27Z (GMT). No. of bitstreams: 1 414875.pdf: 8343665 bytes, checksum: eca6520ad66453c0339e6ec79200478b (MD5) Previous issue date: 2009-01-14 / O objetivo deste ensaio cl?nico randomizado tipo boca dividida foi avaliar e comparar o fechamento dos espa?os durante a retra??o dos caninos permanentes superiores com os br?quetes autoligado SmartClip e convencional Gemini. A amostra foi constitu?da de 13 pacientes portadores de maloclus?o de Classe I com biprotrus?o ou Classe II 1? divis?o de Angle, com m?dia de idade de 18 anos e 4 meses, sendo 3 do g?nero masculino e 10 do feminino. Todos os indiv?duos foram submetidos ? extra??o terap?utica dos primeiros pr?-molares superiores. A retra??o dos caninos foi realizada atrav?s de cadeia elastom?rica com for?a de 150g. As avalia??es foram realizadas nos tempos (T1 inicial, T2 4 semanas, T3 8 semanas, T4 12 semanas) atrav?s de modelos de gesso. Foram analisadas a taxa da movimenta??o e rota??o dos caninos bem como a perda de ancoragem dos primeiros molares permanentes superiores. A mensura??o do fechamento dos espa?os foi realizada entre o canino e o segundo pr?-molar e a rota??o atrav?s do ?ngulo formado pela intersec??o da linha que passava pelos pontos de contato dos caninos com a linha da rafe palatina mediana. A perda de ancoragem foi medida por um guia adaptado ?s rugas palatinas nos modelos de gesso inicial e final. Os dados obtidos foram submetidos a an?lise estat?stica atrav?s do teste t-Student considerando o n?vel de signific?ncia de 5%. Os resultados demonstraram que o br?quete autoligado apresentou taxa m?dia de movimenta??o mensal de 0,92mm (+/- 0,29) e rota??o de 8,46o (+/- 4,68) dos caninos superiores e a perda de ancoragem de 0,65mm (+/- 0,24); o br?quete convencional apresentou taxa m?dia de movimenta??o mensal de 0,84mm (+/- 0,22) e rota??o de 11,77o (+/- 3,26) dos caninos superiores e a perda de ancoragem de 0,57mm (+/- 0,24). N?o houve diferen?a significativa (p=0,250) entre a taxa de movimenta??o dent?ria dos caninos entre os dois tipos de br?quetes. O controle de rota??o dos caninos foi melhor promovido pelo br?quete autoligado (p=0,005). Ocorreu perda de ancoragem para ambos os grupos, sem diferen?a estat?stica entre eles (p=0,157).
147

An?lise comparativa do efeito de diferentes superf?cies sobre a resposta tecidual perimplantar em regi?es com baixa densidade ?ssea : modelo animal coelho

Post, Let?cia Kirst 13 August 2009 (has links)
Made available in DSpace on 2015-04-14T13:29:27Z (GMT). No. of bitstreams: 1 417615.pdf: 921449 bytes, checksum: b1758518b6fea65cac8a47bf9564b908 (MD5) Previous issue date: 2009-08-13 / As possibilidades de modifica??o das propriedades de superf?cie dos implantes s?o muito grandes, tanto com rela??o aos aspectos qu?mico e biol?gico quanto aos morfol?gico e topogr?fico. Pesquisas recentes t?m-se dedicado a buscar uma superf?cie que otimize o processo de osseointegra??o em regi?es com baixa densidade ?ssea. Assim, o objetivo deste estudo foi avaliar a influ?ncia de diferentes superf?cies implantares sobre a resposta tecidual em regi?es com baixa densidade ?ssea. Foram utilizados para este estudo 8 coelhos machos da ra?a Nova Zel?ndia. Em cada animal foram inseridos, cirurgicamente, 4 implantes cil?ndricos, sendo na t?bia direita as amostras dos grupos G1 (superf?cie usinada) e G2 (tratamento com ataque ?cido de rotina) e na t?bia esquerda as amostras dos grupos G3 (superf?cie com camada porosa de tit?nio) e G4 (superf?cie com camada porosa de tit?nio mais tratamento com ataque ?cido inovador) O experimento foi repetido, de forma id?ntica, em todos os animais. Durante todo o per?odo de observa??o (30 dias), os animais permaneceram saud?veis, com cicatriza??o normal na regi?o operada, sem evid?ncia de infec??o ou deisc?ncia de sutura. Todos os implantes obtiveram estabilidade ao tecido perimplantar, mesmo ap?s o processo de descalcifica??o ?ssea. Em alguns grupos da amostra a neoforma??o ?ssea cobriu a por??o coronal n?o submersa dos implantes. Os resultados da an?lise histol?gica evidenciaram que a interface ?ssea com os implantes dos grupos G1 e G2 foi caracteristicamente linear e regular e com G3 e G4 mais irregular. De modo geral, os implantes do grupo G3 melhor contribu?ram para a din?mica do reparo ?sseo.
148

Avalia??o da carga inorg?nica de resinas compostas de conte?do nanom?trico

H?rlle, Lucas 20 January 2009 (has links)
Made available in DSpace on 2015-04-14T13:29:28Z (GMT). No. of bitstreams: 1 418300.pdf: 3151523 bytes, checksum: aeea57ce4111e17b6c94b365bb2412d1 (MD5) Previous issue date: 2009-01-20 / O objetivo deste estudo foi analisar a carga inorg?nica de resinas compostas de conte?do nanom?trico. Foi determinando o conte?do de carga em peso incorporado a cada material (TGA), o conte?do inorg?nico atrav?s da microscopia eletr?nica de varredura (MEV), suas dimens?es e morfologia, al?m dos componentes em peso pelo teste de Espectrografia por Dispers?o de Raios X (EDS). As resinas compostas Esthet X, Filtek Supreme XT e Grandio foram divididas em seis grupos de acordo com a marca da resina composta e a cor. Os valores do conte?do de carga variaram de 75,75 a 87 Wt% para o grupo Esthet X D e o grupo Grandio E, respectivamente. ? an?lise por EDS, os elementos O e Si foram observados em todos os grupos. Al foi observado nos grupos das resinas compostas Esthet X e Grandio e Ba n?o foi observado nos grupos Grandio E, Filtek Supreme E e Filtek Supreme D. Os resultados obtidos sobre os valores m?dios (μm) foram: Esthet X E 1,16в; Esthet X D 1,39в; Filtek Supreme E 0,6в; Filtek Supreme D 1,14в; Grandio E 2,05Aв e Grandio D 3,1A. Na an?lise da morfologia das part?culas, as resinas compostas Esthet X e Grandio apresentaram caracter?sticas semelhantes entre si com grande quantidade de part?culas de carga inorg?nica irregulares, de morfologia heterog?nea. Por outro lado, os grupos da resina Filtek Supreme XT apresentaram caracter?sticas diferentes das demais e semelhantes entre si, quanto ? morfologia. Evidenciaram grande quantidade de part?culas de carga inorg?nica esf?ricas, regulares, com distribui??o e tamanho homog?neos. Os resultados mostraram diferentes formas e tamanhos de part?culas inorg?nicas, independente do tipo de resina composta. P?de-se concluir que as resinas compostas apresentaram caracter?sticas f?sicas de forma e tamanho das part?culas de carga inorg?nica nem sempre coincidindo com as apresentadas pelos fabricantes e comprovada pela literatura.
149

Microdureza, m?dulo de elasticidade e grau de cristalinidade de comp?sitos ativados por LED e luz hal?gena com diferentes densidades de energia

Rodrigues, Patr?cia Silva Hamester 16 January 2009 (has links)
Made available in DSpace on 2015-04-14T13:29:28Z (GMT). No. of bitstreams: 1 418704.pdf: 399268 bytes, checksum: e46093bbe376f77e85de6f280fd10dde (MD5) Previous issue date: 2009-01-16 / Este estudo avaliou a influ?ncia da densidade de energia (intensidade de energia luminosa x tempo de exposi??o) na microdureza, no m?dulo de elasticidade e no grau de cristalinidade das resinas compostas Rok (SDI) Filtek Z250 (3M ESPE) Filtek LS (3M ESPE) e Amelogem Plus (Ultradent). Para a confec??o dos corpos-de-prova foram utilizadas matrizes de acr?lico quadradas com 4mm de espessura e um orif?cio central de 8mm de di?metro A resinas foram inseridas em dois incrementos e fotopolimerizadas com aparelho de luz hal?gena XL 3000 (600mW/cm2) e LED Celalux (800mW/cm2) com 8 e 16J/cm2 de energia luminosa para cada uma das resinas, totalizando 16 grupos. Ap?s a fotoativa??o o conjunto matriz/disco foi polido com lixas de carbeto de sil?cio umidecidas em ?gua e seguidas de polimento com pasta de ?xido de alum?nio com 6&#956;m, 3&#956;m, 1&#956;m, 0,25&#956;m. As amostras foram armazenadas em ?gua destilada em temperatura ambiente por 24h. Decorrida esta etapa as amostras foram submetidas aos testes de microdureza e m?dulo de elasticidade pelo sistema Fischerscop HV 100 e medidas do grau de cristalinidade atrav?s de XRD 7000. Os dados foram submetidos aos testes de Shapiro-Wilk , ANOVA e teste de Tukey com n?vel de confian?a de 95%. Os resultados mostraram que houve diferen?a significativa entre as resinas avaliadas para a microdureza (p<0,01) e o m?dulo de elasticidade (p<0,01) quando fotoativados com 8 e 16J/cm2. O aparelho fotopolimerizador LED apresentou melhores resultados quando comparado ao aparelho de luz hal?gena. A resina composta Filtek LS apresentou padr?o mais cristalino de cadeia polim?rica do que as resinas baseadas em Bis-GMA, Bis-EMA e UDMA, entretanto, a resina com matriz baseada em siloranos apresentou os menores valores para o m?dulo de elasticidade e microdureza. Conclus?o: A densidade de energia assim como a fotopolimeriza??o com aparelhos LED podem afetar significativamente a microdureza e m?dulo de elasticidade de resinas compostas com diferentes composi??es de matriz org?nica.
150

Avalia??o "in vitro" da resist?ncia ? abras?o de resinas compostas comerciais ? base de dimetacrilato e uma ? base de silorano fotoativadas com duas densidades de energia. / A influ?ncia de dentifr?cios clareadores na rugosidade superficial de duas resinas compostas comerciais.

Barbieri, Guilherme Machado 16 January 2009 (has links)
Made available in DSpace on 2015-04-14T13:29:30Z (GMT). No. of bitstreams: 1 411472.pdf: 3421246 bytes, checksum: 2de63642b6d6b46a8c8709c79bb57f6a (MD5) Previous issue date: 2009-01-16 / Artigo 1 - Objetivo: Comparar a rugosidade de superf?cie de quatro resinas compostas com diferentes composi??es de matriz org?nica, atrav?s do ensaio de abras?o por escova??o simulada at? 20.000 ciclos. Materiais e M?todos: Cento e sessenta corpos de prova foram confeccionados e divididos em 16 grupos (n=10) conforme o tipo de resina, fonte de luz e quantidade de energia. As resinas utilizadas foram Charisma, Z250, ROK e Filtek LS, sendo fotopolimerizadas com LED ou Luz hal?gena, recebendo 8 ou 16 J/cm?. Ap?s 24 horas, os corpos de prova foram submetidos ? escova??o simulada com dentifr?cio e escova macia por per?odos de tempo equivalentes ? 6 meses (5000 ciclos), 12 meses (10.000 ciclos) e 24 meses (20.000 ciclos). Ap?s cada per?odo foi realizada a medi??o da rugosidade de superf?cie. Resultados: Fatores como energia (p=0,0001), tipo de fonte (p=0,0047), resinas (p=0,0001) e ciclo (p=0,0001) influenciaram nos resultados obtidos. Os valores de rugosidade m?dia obtidos foram (m?dias seguidas de mesma letra n?o apresentam diferen?a est?stica para Tukey (&#945;=5%): 0,07&#956;m (A) para ROK; 0,08?m (B) para Z250; 0,12&#956;m (C) para Charisma e 0,17&#956;m (D) para filtek LS. Conclus?o: as resinas compostas que cont?m UDMA apresentam maior resist?ncia ? abras?o de superf?cie; resinas baseadas em Siloranos apresentam a menor resist?ncia ao desgaste por abras?o e resinas compostas fotoativadas com 16J/cm? apresentam menor rugosidade de superf?cie do que as polimerizadas com 8J/cm?. Artigo 2 - Objetivos: O objetivo deste estudo foi comparar a rugosidade de superf?cie de duas resinas compostas, com diferentes composi??es org?nicas, quando submetidas ao ensaio de abras?o por escova??o com dentifr?cios clareadores. Materiais e m?todos: Quarenta e oito corpos-de-prova foram confeccionados, divididos em 6 grupos (n=8) conforme tipo de resina e dentifr?cio utilizado. As resinas foram submetidas a ciclos de escova??o os quais simularam at? 24 meses. Ap?s cada per?odo simulado, as resinas compostas tiveram a rugosidade de superf?cie mensurada. Resultados: as m?dias finais de rugosidade de superf?cie (Ra), em &#956;m, para os dentifr?cios Colgate total 12 (controle), Colgate Max White e Close up Extra Whitening foram, respectivamente (m?dias seguidas de mesma letra n?o apresentam diferen?a estat?stica significante para ANOVA e Tukey (p<0,05)): 0,09 (B), 0,12 (B) e 0,11 (B) para a resina ROK; e 0,09 (B), 0,21 (A) e 0,21(A) para Z250. Conclus?es: A resina composta ROK apresentou menor rugosidade de superf?cie do que a resina Z250. As resinas compostas ROK e Z250 tem a sua resist?ncia ao desgaste superficial diminu?da com o uso de dentifr?cios mais abrasivos e utilizados para clareamento dos dentes: Colgate Max-White e Close Up Extra-Whitening.

Page generated in 0.0452 seconds