• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 66
  • 56
  • 22
  • 17
  • 14
  • 8
  • 7
  • 7
  • 7
  • 4
  • 1
  • 1
  • 1
  • Tagged with
  • 216
  • 23
  • 22
  • 22
  • 21
  • 20
  • 16
  • 16
  • 16
  • 14
  • 14
  • 14
  • 13
  • 13
  • 13
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
51

Oxidation of Single and Dual Phase NiCrAl(Y) Bond Coat Alloys

Hu, Lin 10 December 2009 (has links)
No description available.
52

Development of Aluminum Oxide (Al2O3) Gate Dielectric Protein Biosensor under Physiologic Buffer

Ren, Fang 19 June 2012 (has links)
No description available.
53

Puxamento de fibras cristalinas do sistema Al2O3-Nd2O3 e o desenvolvimento de ponta cristalina para aplicação em termoterapia pontual a quente / Crystal fibers pulling from the Al2O3-Nd2O3 system and the development of crystal tip for application in punctual hot thermotherapy

Marcondes, Sergio Paulo 30 May 2014 (has links)
A radiação laser tem sido amplamente utilizada em diversos dispositivos para aplicações tecnológicas. Uma área particularmente interessante que tem sido explorada para o desenvolvimento destes dispositivos é a medicina. Um campo da medicina que tem se beneficiado desse esforço é a termoterapia a laser. No entanto, algumas desvantagens do uso em larga escala desta tecnologia são devidas à falta de uniformidade da absorção da radiação pelo tecido humano. Uma maneira proposta de resolver esta problemática tem sido a utilização de um método fototérmico indireto para converter a energia da luz do laser em calor; por meio de uso de pontas de fibras ópticas revestidas. Contudo, o uso dessas pontas apresenta a desvantagem da limitada estabilidade química do revestimento. Neste trabalho, apresentamos os resultados do desenvolvimento de pontas cristalinas de Nd2O3 altamente estáveis quimicamente em fibras monocristalinas de safira (Al2O3) obtidas diretamente a partir da fase líquida (fundida), fazendo-se uso da técnica Laser-Heated Pedestal Growth (LHPG). A metodologia desenvolvida permite a produção de pontas de diâmetros variados, o que possibilita definir a dimensão da região de aquecimento dentro dos limites de interação ponta cristalina/meio. Para o crescimento dos cristais no formato de fibras, chamados de fibras monocristalinas, usando-se a técnica LHPG, preparamos pedestais de Al2O3 puros e de composição Nd2O3, utilizando-se a técnica de extrusão a frio. Fibras monocristalinas de safira de 0,67 mm de diâmetro e 200 mm de comprimento, livres de poros ou trincas, com pontas cristalinas aproximadamente cônicas foram fabricadas em atmosfera aberta. Para avaliarmos a eficiência da conversão de luz em calor, as fibras foram bombeadas com luz de um laser de comprimento de onda 810 nm. Uma correspondência linear entre a potência do laser e a temperatura da ponta cristalina foi determinada em nossos sistemas e valores de até 250 oC podem ser alcançados; o que torna a ponta cristalina da fibra promissora para aplicações em termoterapia a laser e para a área de soldagem em micro(nano) eletrônica. Neste trabalho apresentamos também um estudo sistemático sobre o processo de puxamento de fibras do compósito eutético Nd2O3-NdAl11O18, através da técnica LHPG, com velocidades de puxamento variando entre 0,08 - 0,92 mm/min. As fibras eutéticas foram fabricadas com sucesso, livres de poros ou trincas. A microestrutura analisada ao microscópio eletrônico de varredura (MEV) foi denominada como do tipo regular, presente em todas as amostras. A despeito da sua complexidade, a microestrutura desse compósito foi controlada e a relação entre o espaçamento médio entre as fases e a velocidade de puxamento &#9552v = constante = (8,2 ± 0,3) µm3/s foi mantida em todo o intervalo das velocidade de puxamento utilizadas. Devido às propriedades mecânicas e ópticas das fases eutéticas individuais, este compósito apresenta-se como candidato com enorme potencial para aplicações dentro da ciência e engenharia de materiais. Ao nosso conhecimento, este trabalho parece ser o primeiro relato sobre a microestrutura eutética do sistema binário Al2O3-Nd2O3. / The laser radiation has been extensively used as devices for technological application, for which the medicine is a hot topic. In this field, the laser-induced thermotherapy is the primary beneficiary of the main researches and applications. However, the heterogeneity associated to the light aborsorption by the human tissue is major impediment preventing the large using of the thermotherapy. To solve this situation, an indirect photothermal method has been employed in order to convert laser radiation into heat by using coated optical fiber tips. Nevertheless, the limited chemical stability of the coating is a crucial problem associated to the large scale application of these coated tips. In the present work, we prepared crystal tips of Nd2O3, chemically stable, coupled in the Al2O3 (sapphire) crystal fiber, being both obtained by the laser-heated pedestal growth technique (LHPG), providing the production of tips with different diameters. Also, the cold extrusion technique was employed to produce the Al2O3 e Nd2O3 pedestals. Besides, the Al2O3 crystal fibers with 0.67 mm in diameter and 200 mm in length, free of cracks and pores, were successfully produced in an air atmosphere. In order to account the efficiency of the light-to-heat conversion, the fibers were pumped with laser light centered at 810 nm. Finally, linear correspondence between laser power and crystal tip temperature was determined in our systems, making them appropriated to the laser-induced thermotheraphy applications and welding in micro- and nano-electronics. Furthermore, we presented a profound investigation about the pulling process of Nd2O3-NdAl11O18 eutectic fibers obtained by LHPG technique. These eutectics were successfully pulled free of cracks and pores. Using scanning electron microscopy (SEM), we were capable of identificating the regular microstructure of our eutectics. Changes in the microstructure were observed in the eutectic fibers pulled using fiber pulling rates from 0.08 to 0.92 mm/min. Despite the complexity of their microstructures, the relation &#9552v = (8,2 ± 0,3) µm3/s = constant, defined by Jackson and Hunt, applied very well for this system. Owing to the mechanical and optical properties of the eutectic phases, these compounds present huge potential for applications in the materials science and engineering related fields. To our knowledge, this work seems to be the first report on the eutectic microstructure of the Al2O3-Nd2O3 binary system.
54

Estudo de materiais com gradiente funcional (MGF) a base de alumina (Al2O3) e carbeto de nióbio (NbC) obtidos por diferentes técnicas de sinterização / Study of functional gradient materials (FGM) made of alumina (Al2O3) and niobium carbide (NbC) obtained by different sintering techniques

Sakihama Uehara, José Luis Hideki 22 July 2015 (has links)
No presente trabalho, peças com gradiente funcional de Al2O3 com reforço de NbC foram planejadas com o intuito de obter um MGF (material com gradiente funcional) com uma alta dureza e boa tenacidade à fratura a partir de diferentes técnicas de sinterização. Os MGFs apresentam-se como uma excelente alternativa quando é necessária a união de materiais com propriedades térmicas ou mecânicas muito diferentes, já que possuem uma transição suave de propriedades ao longo do corpo, como consequência de uma mudança gradual do teor das fases. No planejamento dos MGFs foram utilizadas análises dilatométricas para compatibilizar o comportamento durante a sinterização de cada camada e assim minimizar as tensões que ocorrem durante a retração, responsáveis por trincas e delaminações. Nos ensaios de dilatometria observou-se que a diferença máxima de retração entre os compósitos de teor de NbC variando de 5 a 30 %p é de 4,85%, assim, foram projetados MGFs com um passo de 5% de NbC, reduzindo esta diferença para 2,73%. Compósitos monolíticos de Al2O3 com diferentes teores de NbC foram sinterizadas a 1500ºC num forno convencional sob atmosfera de grafite. As densidades das peças sinterizadas foram inferiores a 90% da densidade teórica (DT), o que comprometeu a dureza dos compósitos (10 a 14 GPa), inferiores que as durezas dos materiais originais. Uma das maiores dificuldades no processamento destes compósitos foi sua densificação, prejudicada devido à presença de partículas de alta refratariedade na matriz de alumina, pelo que foi realizado um estudo do efeito da nióbia (Nb2O5) como auxiliar de sinterização nos compósitos Al2O3-NbC. Utilizando 0,5 %mol deste aditivo foi possível melhorar as densidades dos compósitos que, segundo os resultados da microscopia eletrônica de varredura (MEV), devido a uma densificação em presença de fase líquida. No entanto, a melhora na densidade é efetiva para temperaturas inferiores a 1450°C devido provavelmente à sobrequeima. Devido às dificuldades para obter peças densas a partir desses compósitos, foi utilizado o processo de Spark Plasma Sintering (SPS), o qual foi bem sucedido para obter peças com gradiente funcional com boa densidade (> 98 %TD) e livres de trincas. O gradiente projetado foi mantido com sucesso após a sinterização e, graças à alta densidade das peças, foi possível atingir altas durezas (até 24,3 GPa) e tenacidade à fratura ~5 MPa.m1/2, fazendo com que estes materiais apresentem potencial de aplicação como ferramentas de corte. / In the present work, Al2O3/ NbC graded composites were designed in order to obtain a FGM with a high hardness and good fracture toughness from different sintering techniques. Functionally graded materials (FGM) present enormous potential on matching materials that have different mechanical and thermal properties via a gradual transition throughout the body, as a consequence of a gradual transition of the phase content. For designing of FGMs, a dilatometric analysis was used for matching the sintering behavior of each layer in order to minimize the thermal strains occurring during shrinkage and that are responsible for cracking and delamination. It was observed that the maximum difference in shrinkage between these composites is 4.85%, which could be reduced to 2.73% if a FGM with step of 5% NbC is produced. Monolithic composites of Al2O3 with different amounts of NbC were sintered at 1500°C in a conventional oven under an atmosphere of graphite, the density of the sintered pieces were less than 90 %TD, compromising the hardness of the composites (10 to 14 GPa) that were lower than the hardness of the original materials. Due to the fact that one of the greatest difficulties in processing these composites is a densification, which is impaired due to the presence of high refractory particles in the alumina matrix, a study of the effect of the niobia (Nb2O5) as a sintering aid in the composite Al2O3-NbC was conducted, with addition of 0.5 mol% was possible to improve the density of the composites, due to the liquid state sintering according to the SEM results. However, this effect is only effective until a temperature of 1450°C probably due to the overfiring. In order to obtain dense bodies from these composites, Spark plasma sintering (SPS) was used. This process was successful for producing functional graded bodies with good density (> 98% TD) and crack free. The designed gradient was successfully maintained after sintering and due to the high density of FGMs, it was possible to attain high hardness (up to 24.3 GPa) and a fracture toughness of ~ 5 MPa.m1/2, showing that these materials have a good potential application as cutting tools.
55

Estudo e desenvolvimento de dosímetros luminescentes opticamente estimulados de a-Al2O3 com nanoestruturas de carbono e óxidos terras-raras para aplicação em radioterapia / Study and development of optically stimulated luminescent dosimeters of -Al2O3 with carbon nanostructures and rare-earth oxides for use in Radiotherapy

Schuch, Franciely Fernanda 17 August 2016 (has links)
A alta sensibilidade e a reprodutibilidade de sinal são características de dosímetros luminescentes opticamente estimulados, que instigam seu uso no controle da qualidade e dosimetria in vivo em Radioterapia. Nesse trabalho, amostras de Al2O3, Al2O3 (1%C) e Al2O3 com diferentes concentrações de terras-raras e de nanoestruturas de carbono foram estudadas para aplicação em Radioterapia. As amostras foram obtidas pelo processo manual de mistura e maceração e inseridas em cápsulas transparentes, com exceção do material Al2O3 (1%C), que foi obtido na forma de pastilhas. Os sinais OSL para todos os materiais testados apresentaram crescimento de resposta com a dose de radiação. A concentração de 0,02% apresentou maior intensidade de sinal para todos os materiais inseridos na alumina, com exceção do carbono grafite (1%). Os materiais foram caracterizados por diferentes técnicas, para análises espectroscópicas e estruturais. A sensibilidade OSL do material Al2O3 (1%C) foi investigada para feixes de elétrons de 5 a 12 MeV, para feixe de fótons de 6 MV e para uma fonte de Irídio-192. Diferentes características dosimétricas OSL dos materiais Al2O3 (0,02%Eu), Al2O3 (0,02%Tb), Al2O3 (0,02%ntC), Al2O3 (0,02%npC) foram investigadas para feixes de fótons de 50 kVp, de 6 MV e para uma fonte de Irídio-192, em um amplo intervalo de doses. Todos os materiais apresentaram reprodutibilidade de sinal OSL (desvios menores que 1%) e homogeneidade de resposta em grupo de até ±95% (conferida para o dosímetro de Al2O3 (0,02%ntC). Todos os materiais estudados apresentaram sensibilidade satisfatória para doses de interesse clínico. Amostras OSL de Al2O3 (1% C), Al2O3 (0,02%ntC) e Al2O3 (0,02%npC) foram utilizadas para um estudo piloto de dosimetria in vivo em Radioterapia. A dosimetria in vivo sugere o possível uso dos dosímetros na rotina clínica em Radioterapia, através do estabelecimento de um protocolo de medidas, calibrações para cada feixe e energia utilizada e controle do sistema de planejamento utilizado para os cálculos de dose. / High sensitivity and signal reproducibility are characteristics of optically stimulated luminescent dosimeter, instigating it use in quality control and in vivo dosimetry in Radiotherapy. In this work, samples of Al2O3, Al2O3 (1%C) and Al2O3 with different concentrations of rare-earth and carbon nanostructures, have been studied and developed for application in Radiotherapy. Samples were obtained by manual mixing and maceration and inserted into transparent capsules, except those of Al2O3 (1%C) which were produced as pellets. The OSL signals for all tested materials showed increasing response with radiation dose. The 0.02% concentration showed the highest signal intensity for all materials inserted into alumina, with exception to carbon graphite (1%). Materials were characterized by various techniques, through spectroscopic and structural analysis. The OSL sensitivity of Al2O3 (1%C) was investigated for electron beams from 5 to 12 MeV, 6 MV photons and an Iridium-192 source. Different dosimetric characteristics of some OSL materials Al2O3 (0.02%Eu), Al2O3 (0.02%Tb), Al2O3 (0.02%ntC), Al2O3 (0.02% npC) were investigated for photons beams of 50 kVp and 6 MV and a source of Iridium-192, in a wide dose range. All materials showed reproducibility of OSL signal (deviations less than 1%) and response homogeneity up to ± 95% (conferred for the dosimeter Al2O3 (0.02%ntC). All studied materials showed satisfactory sensitivity. Samples of Al2O3 (1%C), Al2O3 (0.02%ntC) and Al2O3 (0.02% npC) were used in a in vivo dosimetry pilot study in radiotherapy. The in vivo dosimetry performed with the developed OSL dosimeters suggest its possible use in clinical practice in Radiotherapy by establishing a measure protocol, calibrations for each beam and energy used and control of the planning system used for dose calculations.
56

Avaliação de dosímetros de óxido de alumínio pela técnica OSL na dosimetria de campos de fótons clínicos utilizados no tratamento radioterápico em arco modulado volumétrico. / Evaluation of aluminum oxide dosimeters using OSL technique in dosimetry of clinical photom beams on volumetric modulated arc treatment

Villani, Daniel 10 April 2017 (has links)
O tratamento utilizando Radioterapia em Arco Modulado Volumétrico é a modalidade mais moderna de radioterapia conformacional de forma que, com superposição de vários campos, as distribuições de dose forneçam uma perfeita conformação ao tumor, diminuindo a probabilidade de complicações nos tecidos normais adjacentes. Nesse sentido, muitos esforços estão sendo investidos para melhorar a conformidade de distribuição de dose, bem como a integração de técnicas de imagem para rastreamento de tumores e correção de variações inter e intrafração. Para isso, um intenso acompanhamento da qualidade dos processos e um programa de garantia de qualidade são fundamentais para a segurança dos pacientes e o cumprimento da legislação vigente; além do uso de diferentes metodologias de dosimetria para inter comparação e validação dos resultados. Este trabalho tem por objetivo avaliar e comparar o desempenho dos dosímetros OSL de óxido de alumínio (Al2O3:C) fabricados pela Landauer Inc. com os fabricados pela Rexon™ na dosimetria de feixes clínicos de fótons de energias altas empregados em radioterapia com tratamento em arco modulado volumétrico (VMAT) utilizando diferentes objetos simuladores. Os dosímetros foram caracterizados para radiação gama do 60Co e para feixes clínicos de fótons de 6 MV típicos de tratamentos por VMAT em condições de equilíbrio eletrônico e de dose máxima respectivamente. Testes de desempenho das leitoras TL e OSL utilizadas e repetibilidade das amostras foram avaliadas. Após realizados todos os testes, os dosímetros foram irradiados na simulação de diferentes tratamentos radioterápicos por VMAT e suas respostas comparadas ao sistema de planejamento. Todos os tipos de dosímetros apresentaram resultados satisfatórios na verificação das doses desse tipo de simulação de planejamento. Os dosímetros de Al2O3:C apresentaram resultados compatíveis entre si e validados pelos outros dosímetros e câmara de ionização. Em relação a melhor técnica, o sistema comercial OSL InLight apresenta maior praticidade e versatilidade para uso e aplicação na rotina clínica. / Treatment using Volumetric Modulated Arc Radiation Therapy is the most modern modality of conformational radiotherapy so that, with the overlapping of several fields, the dose distributions provide a perfect conformation to the tumor, reducing the probability of complications in adjacent normal tissues. In this sense, many efforts are being invested to improve dose distribution compliance as well as the integration of imaging techniques for tumor screening and correction of inter and intrafraction variations. To this end, an intensive monitoring of the quality of the processes and a quality assurance program are fundamental for patient safety and compliance with current legislation; besides the use of different dosimetry methodologies for intercomparison and validation of the results. The aim of this study is to evaluate and compare the performance of aluminum oxide (Al2O3:C) OSL dosimeters manufactured by Landauer Inc. with those produced by Rexon™ in the dosimetry of high energy photon clinical bundles used in arcuate treatment Modulated volumetric (VMAT) using different simulating objects. The dosimeters were characterized for gamma radiation of the 60Co and for clinical photon beams of 6 MV typical of treatments by VMAT under conditions of electronic equilibrium and maximum dose respectively. Performance tests of the TL and OSL readers used and repeatability of the samples were evaluated. After all tests, the dosimeters were irradiated in the simulation of different radiotherapy treatments by VMAT and their responses compared to the planning system. All types of dosimeters presented satisfactory results in verifying the doses of this type of planning simulation. The Al2O3:C dosimeters presented compatible results and validated by the other dosimeters and ionization chamber. Regarding the best technique, the OSL InLight commercial system presents greater practicality and versatility for use and application in the clinical routine.
57

Influência da adição de NbC e Al2O3+TiO2 nos desempenhos de revestimentos a base de Ni-Al produzidos por aspersão térmica / Influence of addition of Al2O3+TiO2 and NbC coatings on the performance of the Ni-Al base produced by thermal spraying

Spirandeli, Bruno Roberto 10 February 2014 (has links)
Aspersão térmica é um processo de produção de revestimentos metálicos, poliméricos, cerâmicos ou compósitos sobre superfícies previamente preparadas que objetiva na maioria das vezes a prevenção contra o desgaste e/ou corrosão e também a recuperação dimensional de superfícies desgastadas. Ligas de Ni-Al são extensivamente empregadas na aspersão térmica para reconstrução dimensional e como camada de ligação como materiais que não se ligam adequadamente à superfície a ser revestida. A baixa dureza e resistência ao desgaste (principalmente em aplicações de reconstrução dimensional) desta liga poderiam ser contornadas pela adição de partículas ou compostos de altas durezas na matéria prima em pó antes da aspersão. Neste trabalho avaliou-se a influência da adição de NbC e do composto cerâmico Al2O3+TiO2 no desempenho ao desgaste de revestimentos de Ni-Al, bem como verificou-se as alterações microestruturais, químicas, e mecânicas decorrentes. Para tanto se adicionou 25%p de NbC ou 25%p do composto Al2O3+TiO2 à liga base de Ni-Al, formando-se dois materiais compósitos: Ni-Al + NbC e Ni-Al + (Al2O3+TiO2). Utilizou-se microscópio eletrônico de varredura com EDS para caracterizar as matérias primas e os revestimentos produzidos, assim como determinar o mecanismo de desgaste nos ensaios de micro-abrasão tipo \"esfera-livre\" e \"esfera-fixa\". Mediram-se as durezas superficiais e as microdurezas das fases por meio dos ensaios Rockwell Superficial e microdureza Vickers. Avaliou-se a resistência ao desgaste por meio de ensaios de micro-abrasão nas modalidades \"esfera-livre\" e \"esfera-fixa\". As adições dos materiais citados na liga a base de níquel alteraram características microestruturais importantes, como aumento do percentual de óxidos, bem como a composição química e distribuição dos elementos nas camadas formadas; ocorreram também aumentos significativos das durezas e nas resistências ao desgaste dos revestimentos. / Thermo Spray is a metallic, polymeric, ceramic and composite coating process applied over a previously prepared surface usually seeking to improve wear and/or corrosion resistance. It is also used to repair worn surfaces restoring the original dimensions. Ni-Al alloys are used as a primer coating to promote the adhesion between surface and incompatible coatings and also extensively in the reconstruction of worn surfaces. The low hardness and wear resistance (when used in reconstruction applications) of this alloy could be improved by the addition of hard particles/composites to the powdered raw material prior to the spray operation. In this work the influence of NbC and Al2O3+TiO2 additions to Ni-Al alloys were evaluated concerning wear performance and the resulting changes in microstructure, chemical and mechanical behavior. The experimental procedure included the preparation of samples of the Ni-Al base alloy with additions of 25wt% of NbC or 25wt% of Al2O3+TiO2, what resulted in two different sprayed composite materials: Ni-Al + NbC e Ni-Al + (Al2O3+TiO2). SEM with EDS microprobe was used to characterize the raw materials, the sprayed coating samples and the type of wear mechanism occurring in the wear tests of the type \"free sphere\" and \"fixed sphere\" micro abrasion that were used to evaluate the wear resistance of the samples. Surface hardness and micro hardness of the different phases in the coatings were evaluated using Rockwell and Vickers micro hardness testing machines respectively. The addition of the hard phases promoted important changes in the Ni-Al base alloy, decreasing the porosity level and increasing the percentage of oxides. Hardness were significantly increased as well as the wear resistance of the coatings.
58

Estudo e desenvolvimento de dosímetros opticamente estimulados para aplicações em radioterapia / Study and development of Optically Stimulated Luminescent dosimeters for Radiotherapy applications.

Schuch, Franciely Fernanda 24 February 2012 (has links)
Dosímetros Luminescentes Opticamente Estimulados (OSL) vêm sendo testados como alternativa dosimétrica no controle da qualidade e verificação de tratamentos por possuir características adequadas para esse fim, como elevada sensibilidade à radiação ionizante, alta resolução espacial e facilidade de leitura. Neste trabalho, o óxido de alumínio, dopado com diferentes concentrações de carbono (Al2O3:C), foi estudado como material dosimétrico OSL. Nanotubos de carbono de paredes simples também foi avaliado como dopante, associados ao mesmo material, Al2O3:NTC, em alguns testes preliminares de resposta em função da dose em feixes de fótons de 50 kVp. O presente trabalho apresenta o processo de fabricação do dosímetro OSL, além de testes dosimétricos envolvendo metodologia experimental e por simulação Monte Carlo com o código PENELOPE para avaliação da resposta dosimétrica do Al2O3:C em função da concentração do carbono dopante. Neste trabalho foi investigada a resposta do dosímetro OSL para doses entre 50 cGy e 1000 cGy, em um amplo intervalo de energia de feixes de fótons. Foi analisada também, a interferência do uso do dosímetro OSL de Al2O3:C nas doses superficial e profunda em tratamentos radioterápicos. O dosímetro Al2O3:C(1%) apresentou diferença percentual máxima de 12% na homogeneidade de resposta em um grupo de 100 dosímetros e linearidade de resposta entre as doses de 50 cGy e 800 cGy para feixes de fótons de alta energia de 1,25 MV, 6 MV e 15 MV. Já para feixes de fótons de baixas energias, de 50 kVp, 120 kVp e 200 kVp, o dosímetro apresentou diferença significativa entre as respostas, evidenciando dependência com a energia. Além disso, foi investigada a estabilidade do sinal OSL em função do tempo e estipulado um tempo mínimo de armazenamento do dosímetro, entre a exposição e a leitura. O dosímetro Al2O3:NTC apresentou um aumento de sensibilidade de até 30% em relação ao dosímetro Al2O3:C(1%). Os resultados encontrados neste trabalho sugerem o uso do material dosimétrico OSL estudado como ferramenta em controle da qualidade em procedimentos clínicos de rotina na Radioterapia. / Optically Stimulated Luminescent dosimeters (OSL) have been tested as a dosimetric alternative in quality control and treatment verification since they have suitable characteristics for this purpose, such as high sensitivity to ionizing radiation, high spatial resolution and readability. In this work the aluminum oxide, doped with different concentrations of carbon (Al2O3:C), was studied as OSL dosimetric material. Single-walled carbon nanotubes were also evaluated as a dopant associated with the same material, Al2O3:NTC, and preliminary tests of response to dose in photon beams of 50 kVp were performed. This work presents the fabrication process of the OSL dosimeter, and dosimetric tests involving experimental methodology and Monte Carlo simulation with PENELOPE code to evaluate the response of the dosimetric Al2O3:C as a function of the concentration of carbon dopant. In this study we investigated the response of the OSL dosimeter for doses ranging from 50 cGy to 1000 cGy in a wide range of energy of photon beams. The interference of the OSL dosimeter Al2O3:C in superficial and deep doses in Radiotherapy treatments was also analyzed. The dosimeter Al2O3:C (1%) had a maximum percentage difference of 12% in the homogeneity of a group of 100 dosimeters and presented linearity of response in a dose range of 50 cGy and 800 cGy for photon beams of high energy of 1.25 MV, 6 MV and 15 MV. As for photon beams of low energies of 50 kVp, 120 kVp and 200 kVp, the dosimeter showed a significant difference between responses, indicationg dependence on energy. In addition, we investigated the stability of the OSL signal as a function of time and set a minimum time of storage of the dosimeter, between exposure and reading. The dosimeter Al2O3:NTC showed an increased sensitivity of up to 30% over the dosimeter Al2O3:C (1%). The findings on this study suggest the use of the material studied as OSL dosimeter as a tool in quality control in routine clinical procedures in Radiotherapy.
59

Étude de la réduction catalytique sélective (SCR) des NOx par un mélange éthanol-ammoniac / Study of the NOx Selective Catalytic Reduction (SCR) by an ethanol-ammonia mixture

Barreau, Mathias 24 October 2017 (has links)
La Réduction Catalytique Sélective des NOx par NH3 est un procédé efficace de dépollution des gaz. Cependant, pour une application sur véhicules Diesel, l'activité à basse température (175-250°C, phase de démarrage du véhicule) reste limitée. De plus, les catalyseurs de NH3-SCR sont sensibles au rapport NO2/NOx, avec un optimum pour NO2/NOx = 0,5. Or, à basse température, la proportion de NO2 est faible car le catalyseur d’oxydation (DOC) placé en amont est également peu actif. L'éthanol (EtOH) est un autre réducteur possible, principalement avec des catalyseurs Ag/Al2O3. Ce système présente également d'une activité limitée à basse température, bien que l'oxydation de EtOH s'accompagne de la formation de NO2. Dans ces travaux, l'association de EtOH et NH3 pour la SCR de NO sur catalyseur Ag/Al2O3 a été étudié. Un effet de synergie a été obtenu, avec un gain important d'activité à basse température. Ce gain ne provient pas directement d'une réaction entre NH3 et EtOH ou ses sous-produits d'oxydation (CH3CHO, CO…), ni uniquement grâce à la réaction entre NO2 (formé par réaction de NO avec EtOH) et NH3. La caractérisation des espèces adsorbées par IRTF et des tests de (H2+NH3)-SCR ont permis de conclure que les espèces H*, provenant de la déshydrogénation de l'éthanol, réagissent avec les NOx pour conduire à des espèces HNOx très réactives avec NH3.Finalement, la mise en œuvre d'un double-lit (2%Ag/Al2O3 + catalyseur de NH3-SCR), afin d'utiliser NH3, NO et NO2 restants, a permis d'obtenir une conversion NOx comprise entre 46 et 95% entre 175 et 250°C. Ce système permet donc une conversion des NOx élevée à basse température en s'affranchissant du NO2 procuré par le DOC. / The NOx Selective Catalytic Reduction is an efficient process for exhaust gas treatment. However, for Diesel vehicles, the activity at low temperature (175-250°C, starting phase of vehicles) remains limited. In addition, the NH3-SCR catalysts are sensitive to the NO2/NOx ratio, with an optimum for NO2/NOx = 0.5. Unfortunately, at low temperature, the proportion of NO2 is low because the oxidation catalyst (DOC) placed upstream is also weakly efficient.Ethanol (EtOH) is another possible reductant, mainly associated with Ag/Al2O3 catalysts. This system also has a limited activity at low temperature, although the oxidation of EtOH is accompanied by NO2 formation. In this work, the association of EtOH and NH3 for the SCR of NO on a Ag/Al2O3 catalyst was studied. A synergistic effect was obtained, with a high gain of conversion at low temperature. This gain neither results from a reaction between NH3 and EtOH or its oxidation by-products (CH3CHO, CO…), nor only by the reaction between NO2 (formed by reaction of NO with EtOH) and NH3. Characterization of adsorbed species by FTIR and (H2+NH3)-SCR experiments led to the conclusion that H* species, resulting from ethanol dehydrogenation, react with NOx to yield HNOx species highly reactive with NH3.Finally, in order to use the remaining NH3, NO and NO2, the use of a dual bed (2%Ag/Al2O3 + NH3-SCR catalyst) allowed a NOx conversion between 46 and 95% from 175 to 250°C. This system consequently allows a high NOx conversion at low temperature, avoiding the NO2 lack at low temperature (low DOC activity).
60

Avaliação de dosímetros de óxido de alumínio pela técnica OSL na dosimetria de campos de fótons clínicos utilizados no tratamento radioterápico em arco modulado volumétrico. / Evaluation of aluminum oxide dosimeters using OSL technique in dosimetry of clinical photom beams on volumetric modulated arc treatment

Daniel Villani 10 April 2017 (has links)
O tratamento utilizando Radioterapia em Arco Modulado Volumétrico é a modalidade mais moderna de radioterapia conformacional de forma que, com superposição de vários campos, as distribuições de dose forneçam uma perfeita conformação ao tumor, diminuindo a probabilidade de complicações nos tecidos normais adjacentes. Nesse sentido, muitos esforços estão sendo investidos para melhorar a conformidade de distribuição de dose, bem como a integração de técnicas de imagem para rastreamento de tumores e correção de variações inter e intrafração. Para isso, um intenso acompanhamento da qualidade dos processos e um programa de garantia de qualidade são fundamentais para a segurança dos pacientes e o cumprimento da legislação vigente; além do uso de diferentes metodologias de dosimetria para inter comparação e validação dos resultados. Este trabalho tem por objetivo avaliar e comparar o desempenho dos dosímetros OSL de óxido de alumínio (Al2O3:C) fabricados pela Landauer Inc. com os fabricados pela Rexon™ na dosimetria de feixes clínicos de fótons de energias altas empregados em radioterapia com tratamento em arco modulado volumétrico (VMAT) utilizando diferentes objetos simuladores. Os dosímetros foram caracterizados para radiação gama do 60Co e para feixes clínicos de fótons de 6 MV típicos de tratamentos por VMAT em condições de equilíbrio eletrônico e de dose máxima respectivamente. Testes de desempenho das leitoras TL e OSL utilizadas e repetibilidade das amostras foram avaliadas. Após realizados todos os testes, os dosímetros foram irradiados na simulação de diferentes tratamentos radioterápicos por VMAT e suas respostas comparadas ao sistema de planejamento. Todos os tipos de dosímetros apresentaram resultados satisfatórios na verificação das doses desse tipo de simulação de planejamento. Os dosímetros de Al2O3:C apresentaram resultados compatíveis entre si e validados pelos outros dosímetros e câmara de ionização. Em relação a melhor técnica, o sistema comercial OSL InLight apresenta maior praticidade e versatilidade para uso e aplicação na rotina clínica. / Treatment using Volumetric Modulated Arc Radiation Therapy is the most modern modality of conformational radiotherapy so that, with the overlapping of several fields, the dose distributions provide a perfect conformation to the tumor, reducing the probability of complications in adjacent normal tissues. In this sense, many efforts are being invested to improve dose distribution compliance as well as the integration of imaging techniques for tumor screening and correction of inter and intrafraction variations. To this end, an intensive monitoring of the quality of the processes and a quality assurance program are fundamental for patient safety and compliance with current legislation; besides the use of different dosimetry methodologies for intercomparison and validation of the results. The aim of this study is to evaluate and compare the performance of aluminum oxide (Al2O3:C) OSL dosimeters manufactured by Landauer Inc. with those produced by Rexon™ in the dosimetry of high energy photon clinical bundles used in arcuate treatment Modulated volumetric (VMAT) using different simulating objects. The dosimeters were characterized for gamma radiation of the 60Co and for clinical photon beams of 6 MV typical of treatments by VMAT under conditions of electronic equilibrium and maximum dose respectively. Performance tests of the TL and OSL readers used and repeatability of the samples were evaluated. After all tests, the dosimeters were irradiated in the simulation of different radiotherapy treatments by VMAT and their responses compared to the planning system. All types of dosimeters presented satisfactory results in verifying the doses of this type of planning simulation. The Al2O3:C dosimeters presented compatible results and validated by the other dosimeters and ionization chamber. Regarding the best technique, the OSL InLight commercial system presents greater practicality and versatility for use and application in the clinical routine.

Page generated in 0.0587 seconds