• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 552
  • 114
  • 20
  • 18
  • 18
  • 17
  • 17
  • 10
  • 10
  • 9
  • 8
  • 4
  • 3
  • 2
  • 2
  • Tagged with
  • 738
  • 738
  • 508
  • 475
  • 153
  • 135
  • 122
  • 109
  • 90
  • 76
  • 76
  • 74
  • 72
  • 70
  • 60
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
151

Análise in vivo da modulação óssea em implantes de titânio com superfície em nanoescala /

Carvalho, Lais Morandini. January 2017 (has links)
Orientador: Luana Marotta Reis de Vasconcellos / Coorientador: Gustavo Mendonça / Banca: Daniela Baccelli Silveira Mendonça / Banca: Elisa Mattias Sartori / Banca: Yasmin Rodarte Carvalho / Banca: Renata Falchete do Prado / Resumo: Nas últimas décadas houve um aumento considerável na utilização dos implantes metálicos para aplicações na área da ortopedia e odontologia, por isso as pesquisas têm como foco estudar os mecanismos biológicos de interação osso-implante. A nanotopografia de superfície de implantes osseointegráveis apresenta efeito direto sobre a resposta biológica óssea. No entanto a maneira como afeta a osseointegração in vivo ainda não está totalmente elucidada. O objetivo neste estudo foi comparar in vivo a influência da superfície em nanoescala (nano) confeccionada em implantes de titânio comercialmente puro (Ticp), comparado-a a superfície lisa (controle) em modelo experimental de camundongos osterix-mcherry (Osx-mcherry), os quais expressam proteína fluorescente concomitante com a expressão do gene osterix (Osx). Os animais receberam implantes de superfície lisa no fêmur direito e com nanoescala no fêmur esquerdo. Após diferentes períodos de eutanásia baseados na metodologia empregada foram realizados nas peças e nas células os seguintes testes biológicos: microscopia eletrônica de varredura (MEV) para avaliação da adesão celular e da superfície do implante; histologia e nanotomografia (nanoCT) para observação e quantificação de osso neoformado na interface osso/implante; citometria de fluxo para quantificação de células marcadas pelo gene osterix; PCR em tempo real (qPCR) para avaliação da expressão gênica; coloração fosfatase ácida resistente ao tartarato (TRAP) para contagem de osteoc... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: In the last decades there has been a considerable increase in the use of metal implants for applications in the area of orthopedics and dentistry, so the researches are focused on studying the biological mechanisms of boneimplant interaction. Surface nanotopography of osseointegrated implants has a direct effect on the biological response of bone. However the way it affects osseointegration in vivo is not yet fully elucidated. The aim of this study was to compare the in vivo influence of the nanoscale surface (nano) made on implants of commercially pure titanium (Ticp) with the smooth surface (control), using an experimental model of osterix-mcherry mice (Osxmcherry), which express fluorescent protein concomitant with osterix gene expression (Osx). The animals received implants with smooth surface in the right femur and nanoscale in the left femur. After different periods of euthanasia based on the methodology used, biological tests were performed in the femur and cells: scanning electron microscopy (SEM) for evaluation of cell adhesion and implant surface; histology and nanotomography (NanoCT) for observation and quantification of neoformed bone at implant interface; flow cytometry for quantification of cells marked by the osterix gene; Realtime PCR (qRT-PCR) for gene expression evaluation; tartrate resistant acid phosphatase staining (TRAP) for osteoclast counts. Our results showed that most genes studied were overexpressed in the nanoscale surface and some of which presented statistical differences(t Test, p <0.05), such as: Osx (osterix), Alp (alkaline phosphatase), Prx1 (related paired homeobox), Dmp1 (Dolicol-phosphatase mannosyltransferase subunit 1), Bsp (bone sialoprotein) and Ocn (osteocalcin). The two-way ANOVA statistical test followed by the Tukey test when necessary were used for the other experiments and the level ...(Resumo completo, clicar acesso eletrônico abaixo) / Doutor
152

Comportamento eletroquímico do Ti2, Ti4, Ti4hard e Ti6Al4V em função de diferentes aplicações tópicas de flúor /

Zanna, Carolina Ferrairo Danieletto. January 2017 (has links)
Orientador: Wirley Gonçalves Assunção / Banca: Leonardo Perez Faverani / Banca: Valentim Adelino Ricardo Barão / Resumo: Pacientes com reabilitações implantossuportadas parciais podem apresentar condições clínicas que necessitem de fluorterapia. Sabe-se que o fluoreto possui uma ação corrosiva em alguns metais, portanto o objetivo deste estudo foi investigar o comportamento eletroquímico e as alterações de superfície, dos titânios Grau 2 (comercialmente puro Grau 2 - Ti2), Grau 4 - Ti4, Grau 4 hard - Ti4h, e Grau 5 - Ti5, comumente utilizados para confecção de implantes e componentes protéticos, frente a exposição de aplicações tópicas de flúor em bochecho e gel. Espécimes cilíndricos (3mm de altura e 8mm de diâmetro) (n=20) foram confeccionados a partir de cada titânio e submetidos a metalografia. A amostra foi dividida em quatro grupos: Baseline (n=20), Controle - C (n=20), Bochecho - B (n=20) e Gel - G (n=20). No Baseline os espécimes foram caracterizados através de microdureza de Vickers, rugosidade superficial - Ra, Microscopia Eletrônica de Varredura - MEV e Espectroscopia de Energia Dispersiva - EED. No Bochecho, os espécimes ficaram imersos em saliva artificial pura (SA) acrescida de NaF (225ppm F-) e mantidos em constante agitação durante 30horas e 41minutos, simulando bochechos diários; no Gel, os espécimes foram imersos em SA acrescida de NaF (12.300ppm F-), mantidos por 1 minuto, na sequência, transferidos para solução de SA pura, na qual permaneceram por 30 minutos (processo repetido 6 vezes), simulando aplicações de flúor fosfato acidulado 1,23% e no Controle, os espécimes não ent... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Patients with partial implant-supported rehabilitations may present clinical conditions that require fluorotherapy. It is known that fluoride has a corrosive action on some metals, so the objective of this study was to investigate the electrochemical behavior and surface changes of grade 2 titanium (commercially pure Grade 2 - Ti2), Grade 4 - Ti4, Grade 4 Hard - Ti4h, and Grade 5 - Ti5, commonly used for the preparation of implants and prosthetic components, against the exposure of topical applications of fluoride in mouthwash and gel. Cylindrical specimens (3mm high and 8mm diameter) (n = 20) were made from each titanium and subjected to metallography. The sample was divided into four groups: Baseline (n = 20), Control - C (n = 20), Bochecho - B (n = 20) and Gel - G (n = 20). In the Baseline the specimens were characterized by Vickers microhardness, surface roughness - Ra, Scanning Electron Microscopy - SEM and Dispersive Energy Spectroscopy - EED. In Bochecho, the specimens were immersed in pure artificial saliva (SA) plus NaF (225ppm F-) and kept in constant agitation for 30hours and 41minutes, simulating daily mouthwashes; In the Gel, the specimens were immersed in SA plus NaF (12,300ppm F-), maintained for 1 minute, then transferred to pure SA solution, in which they remained for 30 minutes (6 times repeated procedure), simulating Fluorinated phosphate 1.23% and in Control, the specimens did not come into contact with fluoride solutions. The groups C, B and G were submit... (Complete abstract click electronic access below) / Mestre
153

Efficacy of detoxifying treatment on dental implant surfaces affected by peri-implantitis

Qari, Maha Rahmatullah 25 October 2017 (has links)
BACKGROUND: Implant therapy has been the gold standard in the past decade when it comes to replacing partially or complete edentulous oral cavities. Patients favor this line of treatment since it does mimic their natural teeth in esthetic, function and phonetics. Unfortunately, some initially integrated implants end up diagnosed with peri-implantitis, which threatens the longevity of those implants in their respective alveolar bone. Several methods have been discussed aiming to either salvage the diseased implant or prolong the life of it in patients’ oral cavities. In this protocol we studied the efficacy of one of the suggested protocols that has been used frequently in periodontal practices aiming to decontaminate the surface of previously diseased implants. MATERIALS AND METHODS: This study looked at the efficacy through two analyses, a descriptive and a quantitative. In the descriptive, several peri-implantitis diagnosed implants were collected and distributed over 4 groups: Test, Negative Control, Positive control and compared to pristine implants. Osteoprogenitor cells were prepared in-vitro and seeded over these implants after applying the protocol on Test group only. The quantitative analysis used the EDX analysis to study the percentages of Titanium and Oxygen on contaminated implants before and after applying the protocol on. Deposits removal was tested as well to ensure efficacy of decontamination protocol. RESULTS: Descriptive analysis showed that osteoprogenitor cells had higher attachment and proliferation on implants that followed the decontamination protocol vs. other groups. Quantitative analysis showed statistically significant higher titanium percentages after decontamination. Oxygen levels were higher as well but not statistically significant. Deposits were statistically significant in removal after decontamination protocol. CONCLUSION: Decontamination of previously diseased implants following the mentioned protocol has efficiently increased the chances of re-establishment of osseointegration in previously contaminated implants.
154

Estudo comparativo in vivo de implantes Ti-cp com superfícies comerciais e modificadas por laser sem e com depósito de sílica : análises biomecânica, topográfica e histomorfométrica /

Souza, Francisley Ávila. January 2010 (has links)
Resumo: Proposição: O objetivo deste estudo foi comparar o comportamento biológico e mecânico do tecido ósseo ao redor de implantes de superfícies comerciais modificada por condicionamento ácido (SA), e usinada (SU), com implantes de superfícies experimentais modificada por laser (SL), e modificada por laser com depósito de sílica (SS), empregando-se as análises biomecânica, topográfica e histométrica. Material e Métodos: Trinta coelhos receberam 120 implantes de 3,75x10mm em suas tíbias direita e esquerda, sendo dois implantes de cada superfície por tíbia. O implante localizado mais superior, instalado na metáfise tibial foi utilizado para o ensaio biomecânico, descrito no capítulo I; e o implante localizado abaixo deste, instalado na epífise tibial foi utilizado para o estudo histométrico, descrito no capítulo II. A morfologia das superfícies dos implantes foi analisada por microscopia eletrônica de varredura (MEV), e por espectroscopia de energia dispersiva de raios X (EDS) antes, e após 4 semanas de implantação e remoção por torque reverso. Medidas de rugosidade e secção transversal foram obtidas. Após períodos de 4, 8, e 12 semanas realizou-se o ensaio biomecânico, e após os animais sofreram eutanásia. As peças do implante localizado na epífise tibial foram levadas ao micrótomo para corte sem descalcificação. A análise histométrica foi realizada empregando-se microscopia óptica. Foi mensurada a extensão linear de contato entre osso e implante (ELCOI), e a área óssea (AO). Uma lâmina de cada superfície do período de 4 semanas foi metalizada para realização da análise do mapeamento elementar por MEV-EDS. Resultados: A caracterização topográfica mostrou diferenças entre as superfícies analisadas, e os valores de rugosidade média das SL e SS foram estatisticamente superiores (p<0,05) a SA. Na comparação estatística dos valores obtidos... (resumo completo, clicar acesso eletrônico abaixo) / Abstract: Purpose: The aim of this study was to compare the biologic and mechanical behavior of bone tissue around implants with commercially available surfaces, modified by acid etching (SA), and machined surfaces (SU), with the experimental surfaces modified by laser (SL), and modified by laser with silica deposition (SS), using biomechanical, topographic and histometric analyses. Materials and Methods: Thirty rabbits received 120 implants measuring 3,75x10mm in their right and left tibias, being two implants of each type of surface per tibia. The implant located in the uppermost position, inserted in the tibial metaphysis, was used for the biomechanical test, described in Chapter I; and the implant located below this, inserted in the tibial epiphysis, was used for the histometric study, described in Chapter II. The morphology of the implant surfaces was analyzed by scanning electron microscopy (SEM) and by energy dispersive X-ray spectrometry (EDS) before and after 4 weeks of implantation and removal by reverse torque. Mean roughness and cross-sectional measurements were obtained. After periods of 4, 8, and 12 weeks the biomechanical test was performed, and after this the animals were euthanized. The parts of the implant located in the tibial epiphysis were taken for cutting nondecalcified on a microtome. Histometric analysis was performed using an optical microscope. The bone interface contact (BIC), and the bone area (AO) were measured in percentages. A slide of each surface in the period of 4 weeks was metalized in order to analyze the element mapping by means of SEM-EDS. Results: The topographic characterization showed differences between the analyzed surfaces, and the mean roughness values of SL and SS were statistically higher (p<0,05) than those of SA. In the statistical comparison of the values obtained by the biomechanical test, it was... (Complete abstract click electronic access below) / Orientador: Celso Koogi Sonoda / Coorientador: Roberta Okamoto / Banca: Antônio Carlos Guastaldi / Banca: Renato Sussumu Nishioka / Banca: Sérgio Bruzadelli Macedo / Banca: Idelmo Rangel Garcia Júnior / Banca: Osvaldo Magro Filho / Doutor
155

Influência da nicotina na osseointegração de implantes instalados em tíbias de ratos: avaliação biomecânica, histológica, histométrica e imunoistoquímica / Influence of nicotine on osseointegration of implants installed in the tibia of rats: biomechanical, histological, histometric and immunohistochemical evaluation

Faleiros, Paula Lazilha [UNESP] 05 July 2016 (has links)
Submitted by PAULA LAZILHA FALEIROS null (paulal.faleiros@hotmail.com) on 2016-08-03T13:15:45Z No. of bitstreams: 1 TESE DE DOUTORADO - PAULA FINAL.pdf: 7373323 bytes, checksum: 4741d1f9d635d1e4879a2cd520afb7ae (MD5) / Rejected by Ana Paula Grisoto (grisotoana@reitoria.unesp.br), reason: Solicitamos que realize uma nova submissão seguindo a orientação abaixo: O arquivo submetido está sem a ficha catalográfica. A versão submetida por você é considerada a versão final da dissertação/tese, portanto não poderá ocorrer qualquer alteração em seu conteúdo após a aprovação. Corrija esta informação e realize uma nova submissão contendo o arquivo correto. Agradecemos a compreensão. on 2016-08-03T13:36:52Z (GMT) / Submitted by PAULA LAZILHA FALEIROS null (paulal.faleiros@hotmail.com) on 2016-08-03T13:55:04Z No. of bitstreams: 1 TESE DE DOUTORADO - PAULA FINAL.pdf: 7377120 bytes, checksum: c55964dddab287b8b096d337e07195bf (MD5) / Approved for entry into archive by Ana Paula Grisoto (grisotoana@reitoria.unesp.br) on 2016-08-03T18:08:55Z (GMT) No. of bitstreams: 1 faleiros_pl_dr_araca_par.pdf: 1921873 bytes, checksum: 138048a39be83d82924179cc13951f8c (MD5) / Made available in DSpace on 2016-08-03T18:08:55Z (GMT). No. of bitstreams: 1 faleiros_pl_dr_araca_par.pdf: 1921873 bytes, checksum: 138048a39be83d82924179cc13951f8c (MD5) Previous issue date: 2016-07-05 / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Objetivo: Avaliar do ponto de vista biomecânico, histomorfométrico, histoquímico e através de marcadores imunoistoquímicos a influência da terapia com laser em baixa intensidade (LLLT) na osseointegração de implantes instalados em tíbias de ratos modificados ou não sistemicamente pela nicotina. Materiais e métodos: Um total de 120 ratos (Wistar) foi distribuído em dois grandes grupos experimentais (n = 60) submetidos a duas aplicações diárias de solução salina (Veh) ou nicotina (Nic). Após 30 dias, implantes de titânio (2.2 mm x 4 mm) foram instalados na metáfise proximal de ambas as tíbias de todos os animais. Grupos experimentais de diferentes tratamentos locais do alvéolo cirúrgico previamente a instalação do implante (n = 30) foram criados no momento da cirurgia: Veh - nenhum tratamento; Veh/LLLT - irradiação do alvéolo cirúrgico com laser em baixa intensidade; Nic - nenhum tratamento; Nic/LLLT - irradiação do alvéolo cirúrgico com laser em baixa intensidade. O laser utilizado foi o Thera Lase (InGaAlP 660 nm, modo de aplicação contínuo, em contato com a área, 35 mW, 0,14 J, 4,9 J/cm2, por 4 segundos). Dez animais de cada grupo foram eutanasiados aos 15, 30 e 60 dias pós-operatórios. As tíbias direitas foram submetidas à análise de torque reverso e posteriormente processadas para confecção de cortes histológicos descalcificados, corados por hematoxilina e eosina, vermelho picrosirius ou submetidos a reações imunoistoquímicas com os anticorpos primários policlonais: HIF-1 α, VEGF, BMP-2, RUNX-2, OCN, ALP, RANKL, OPG e TRAP. A partir das tíbias esquerdas foram preparados cortes histológicos calcificados para análise das porcentagens de contato osso-implante (BIC) e área óssea (BA), dentro dos limites das roscas do implante. A análise foi realizada através da microscopia de luz polarizada para análise histoquímica e da microscopia óptica de campo claro para a análise histológica, histométrica e imunoistoquímicas. As imunomarcações foram submetidas à análise qualitativa para os anticorpos HIF-1 α, VEGF, BMP-2, OCN, ALP, RANKL e OPG e análise quantitativa para os anticorpos RUNX-2 e TRAP. Os dados quantitativos foram analisados estatisticamente (p≤0,05). Resultados: A nicotina atrasou a produção de elementos da matriz óssea, diminuiu o padrão de imunomarcação de HIF-1α, VEGF, BMP-2, OCN, ALP e OPG, aumentou o padrão de imunomarcação de RANKL e aumentou a quantidade de células imunorreativas a RUNX-2 e TRAP, diminuindo a BA, embora não tenha sido capaz de influenciar o torque de remoção e o BIC. O laser aumentou o padrão de imunomarcação de HIF-1α, VEGF, BMP-2, OCN e ALP, aumentou a quantidade de células imunorreativas a RUNX-2 e TRAP, aumentou a BA, mas também não foi capaz de influenciar o torque de remoção e o BIC. Adicionalmente, o laser influenciou positivamente a BA e o torque de remoção dos implantes, aumentou a angiogênese e a diferenciação osteoblástica, promovendo a formação óssea, biomineralização e maturação óssea peri-implantar nos animais modificados sistemicamente pela nicotina. Conclusão: A LLLT é capaz de promover o processo de reparo ósseo peri-implantar em condições normais e compensar os efeitos negativos da nicotina na osseointegração. / Objective: To evaluate, from biomechanical, histomorphometric, histochemical stand point and through of immunohistochemical markers, the influence of low level laser therapy (LLLT) on the osseointegration of implants placed in the tibias of nicotine systemically modified (or not) rats. Materials and methods: A total of 120 rats (Wistar) was assigned into two major experimental groups (n = 60) underwent two-daily-applications of saline (Veh) or nicotine (Nic). After thirty days, titanium implants (2.2 mm x 4 mm) were placed in the proximal metaphysis of both tibiae from all animals. Experimental groups of different surgical alveolus local treatments prior to implant placement (n = 30) were created at the moment of the surgery: Veh - no local treatment; Veh/LLLT - irradiation of surgical alveoli with low level laser; Nic - no local treatment; Nic/LLLT - irradiation of surgical alveoli with low level laser. The laser used was Thera Lase® (InGaAIP 660 nm, in continuous mode, in contact with the area, 35 mW, 0.14 J, 4.9 J/cm2 , for 4 seconds). Ten animals from each group were euthanized at 15, 30 and 60 days postoperative. The right tibiae were submitted to reverse-torque analysis and, then processing in order to prepare decalcified histological sections, stained either by hematoxylin and eosin or picrosirius red or subjected to immunohistochemical reactions with the primary polyclonal antibodies: HIF-1 α, VEGF, BMP-2, RUNX-2, OCN, ALP, RANKL, OPG and TRAP. From left tibias were prepared undecalcified histological sections to evaluate the percentages of bone-to-implant contact (BIC) and bone area (BA) within the limits of the implant threads. The histochemical analysis was performed by a polarized light microscopy and the histological, histometric and immunohistochemical analysis were performed by a bright field optical microscopy. The HIF- 1α, VEGF, BMP-2, OCN, ALP, RANKL and OPG immunostaining were submitted to qualitative analysis and the RUNX-2 and TRAP immunostaining were submitted to quantitative analysis. Quantitative data were analyzed statistically (p≤0.05). Results: The nicotine delayed the production of bone matrix components, decreased the imunolabeling pattern of HIF-1α, VEGF, BMP-2, OCN, ALP and OPG, increased the imunolabeling pattern of RANKL, increased the amount of RUNX-2 and TRAP-immunoreactive cells, reduced the BA, but did not influence the BIC and the force required to break the osseointegration. The laser increased the imunolabeling pattern of HIF-1α, VEGF, BMP-2, OCN and ALP, increased the amount of RUNX-2 and TRAP-immunoreactive cells, increased the BA, but also was not be able to influence the BIC and the force required to break the osseointegration. In addition, the laser positively influenced the BA and the implant removal torque, increased the angiogenesis and osteoblast differentiation, promoted bone formation, biomineralization and peri-implant bone maturation in the nicotine systemically modified rats. Conclusions: LLLT is able to promote the peri-implant bone repair process in normal conditions and is able to compensate the negative effects of nicotine on osseointegration. / FAPESP: 2013/11863-0
156

Estudo comparativo do Biogran® e Endobon® associados a implantes com defeitos periimplantares

Carvalho, Helen Ramon Esper de [UNESP] 04 September 2015 (has links) (PDF)
Made available in DSpace on 2016-02-05T18:30:11Z (GMT). No. of bitstreams: 0 Previous issue date: 2015-09-04. Added 1 bitstream(s) on 2016-02-05T18:34:21Z : No. of bitstreams: 1 000857959.pdf: 2588157 bytes, checksum: e2c7920ee93dc1516ef1b9eceaece7bd (MD5) / Introdução: A utilização de biomateriais em reconstruções para implantodontia tem sido amplamente discutida nos últimos anos. Proposição: O objetivo deste trabalho foi analisar o comportamento biológico do vidro bioativo (Biogran®) e do osso bovino (Endobon®) durante o processo de osseointegração associados a implantes com defeitos periimplantares em tíbias de rato. Material e método: Foram instalados 75 implantes na tíbia esquerda de 75 ratos Wistar machos. Os implantes foram divididos em três grupos experimentais. No Grupo 1 (Controle) foi provocado um defeito periimplantar monocortical circular e os implantes foram inseridos e deixados apenas com coágulo. No Grupo 2 os implantes foram inseridos com o mesmo defeito ósseo e o espaço preenchido com Biogran® e no Grupo 3 o espaço entre osso e implante foi preenchido com Endobon®. Os animais foram submetidos à eutanásia aos 14 e 42 dias e realizaram-se as análises histológica, histométrica (porcentagem de extensão linear de contato osso-implante - BIC e área óssea - BA), imunoistoquímica (expressão das proteínas osteocalcina - OC e osteopontina - OPN) e biomecânica (torque reverso). Resultados: Histologicamente todos os implantes encontraram-se osseointegrados. Não foram observadas diferenças estatisticamente significantes nos valores de torque reverso (p> 0,05) aos 42 dias. Para BIC, aos 14 dias foi de 8,29; 15,04; e 16,20%, para os grupos 1, 2 e 3, respectivamente. Aos 42 dias, os valores médios de BIC foram 30,84; 33,13; e 13,93% para os mesmos grupos, demonstrando que não houveram diferenças estatísticas entre grupos, porém com respostas diferentes entre períodos. Para a quantificação de formação óssea por área (BA), a resposta entre grupos difere. A resposta da BA média do Grupo 1 (18,75%) não difere da resposta média do Grupo 3 (21,62%). Porém, difere... / Introduction: The use of biomaterials in reconstructions for dental implants has been widely discussed in recent years. Proposition: The aim of this work was to analize the biological behavior of the bioactive glass (Biogran®) and bovine bone (Endobon®) during the osseointegration process associated with implants with peri-implant defects in rat tibia. Material and Methods: 75 implants were installed in the left tibia of 75 male Wistar rats. The implants were divided into three experimental groups. In Group 1 (Control) was caused monocortical circular peri-implant defect and the implants were inserted and left only with clot. In Group 2 implants were inserted with the same bone defect and the space filled with Biogran® and in Group 3 the space between bone and implant was filled with Endobon®. The animals were euthanized at 14 and 42 days and there were the histological analysis, histometric (percentage of linear extension bone-implant contact - BIC and bone area - BA), immunohistochemistry (expression of the proteins osteocalcin - OC and osteopontin - OPN) and biomechanics (reverse torque). Results: Histologically all implants were osseointegrated. No statistically significant differences were observed in the values of reverse torque (p> 0.05) at 42 days. For BIC, at 14 days was 8.29; 15.04; and 16.20% for the groups 1, 2 and 3, respectively. After 42 days, the BIC values were 30.84; 33.13; and 13.93% for the same groups, demonstrating that there were no statistical differences between groups, but with different responses between periods. For the quantification of bone formation per area (BA), the response differs between groups. The average BA response in Group 1 (18.75%) did not differ from the average Group 3 response (21.62%). However, different from Group 2 (34.73%). The immunohistochemical results were analyzed by Qualitative...
157

Reparo ósseo em defeito peri-implantar com e sem associação de enxerto ósseo autógeno obtido por Piezocirurgia: estudo experimental em coelhos

Homsi, Nicolas [UNESP] 22 August 2011 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:07Z (GMT). No. of bitstreams: 0 Previous issue date: 2011-08-22Bitstream added on 2014-06-13T19:40:59Z : No. of bitstreams: 1 homsi_n_dr_araca.pdf: 690157 bytes, checksum: 4f4e024d5301db266278d9736fbf0050 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Proposição: A proposta deste estudo foi avaliar por análise histométrica a resposta tecidual óssea de enxerto autógeno coletado por piezocirurgia para o preenchimento de defeitos nas porções cervicais de implantes instalados em tíbias de coelhos. Métodos: Foram instalados 26 implantes em 13 tíbias de coelho, após a estabilidade inicial foram realizados defeitos cervicais por trefinagem, em um grupo foi mantido apenas o coágulo como preenchimento e em outro grupo o defeito foi preenchido por osso autógeno coletado por equipamento piezoelétrico, os animais foram sacrificados após 15 e 30 dias, a análise histométrica das interfaces implante-osso foram realizadas pelo software Image Lab. Resultados: Foi analisado o percentual de extensão linear de contato entre tecido ósseo e implante, a média percentual obtida de contato entre tecido ósseo neoformado e implante foram estabelecidas como médias da área de osso neoformado entre as espiras e contato osso-implante (BIC). Os resultados obtidos foram: no controle de 15 dias, o percentual entre as espiras foi de 65,2% e entre as espiras e contato osso-implante (BIC) de 88,7%. No controle de 30 dias o contato entre as espiras foi na ordem de 65,2% e entre as espiras e contato osso-implante (BIC) de 73,2%. No grupo de enxerto de 15 dias, o osso formado entre as espiras foi de 69,3% e entre as espiras e contato osso-implante (BIC) em 81%, no grupo enxerto 30 dias o osso formado entre as espiras foi de 91,47% e entre as espiras e contato ossoimplante (BIC) 91,56%. Conclusão: o enxerto ósseo autógeno particulado obtido por piezocirurgia apresenta melhor resultado que o coágulo sanguíneo no osso neoformado entre as espiras e no contato osso-implante / Purpose: The purpose of this study was to evaluate by histometric analysis the outcome of autogenous bone collected through piezo surgery equipment in filling cervical portion defects around implants placed in rabbits tibias. Materials and Methods: Twenty-six implants were installed in 13 rabbits tibias, after initial primary stability, cervical defects were carried out by the use of a trephina, in one group the cloth was maintained as the defect filling and in another group the defect was filled by autogenous bone collected through piezo surgery equipment, the animals were sacrificed after 15 and 30 days, the histometric analysis of the implant-bone interfaces were carried out by the use of Image Lab software. Results: The lineal stretch percentage of contact between bone and implant was analyzed, the average percentage obtained in the contact between the newly formed bone and the implant was established as the average area of the newly formed bone in the space between the spires and the bone-implant contact (BIC). The results obtained were: in the 15-days control group, the percentage of bone formation between the spires was of 65.2% and between the spires and boneimplant contact (BIC) was of 88.7%. In the 30-days control group the contact between the spires was of 65.2% and between the spires and bone-implant contact (BIC) of 73.2%. In the 15-days control grafted group, the formed bone between the spires was of 69.3% and between the spires and bone-implant contact (BIC) of 81%, in the 30-days control grafted group, the formed bone between the spires was of 91.47% and between the spires and bone-implant contact (BIC) of 91.56%. Conclusions: the autogenous bone collected through piezo surgery equipment showed better results than the blood clot regarding the newly formed bone between the spires and bone-implant contact (BIC)
158

Avaliação de substitutos ósseos em defeitos peri-implantares criados em coelhos

Santos, Pâmela Letícia dos [UNESP] 28 March 2013 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:07Z (GMT). No. of bitstreams: 0 Previous issue date: 2013-03-28Bitstream added on 2014-06-13T20:41:19Z : No. of bitstreams: 1 santos_pl_dr_araca.pdf: 1518173 bytes, checksum: 780aa208fda4e1610407dd0ff2ab5be9 (MD5) / Objetivo: Avaliar a efetividade dos substitutos ósseos, matriz de osso bovino mineralizada – (Bio-Oss®) e matriz de osso bovino mineralizada com adição de 10% de colágeno suíno – (Bio-Oss® Collagen), no preenchimento de defeitos peri-implantares criados em tíbia de coelhos, por meio das análises biomecânica, histológica e imunoistoquímica para a expressão das proteínas OC, Runx 2, OPG, RANK-L e TRAP . Material e Métodos: Trinta coelhos receberam 1 ostectomia em cada tíbia por meio de trefina de 6.1 mm de diâmetro. Em seguida, foram utilizadas as fresa lança e helicoidais no preparo de leitos receptores com 3,0mm e 1 implante de 4,1 mm/8,5 mm foi instalado. Os defeitos ósseos peri-implantares foram preenchidos de acordo com os seguintes grupos: I- coágulo sanguíneo (CO); II- Bio-Oss® (BI); e III- Bio-Oss® Collagen (BC). Dez animais por período foram eutanasiados aos 15, 30 e 60 dias pós-operatórios, para as análises biomecânica, histológica e imunoistoquímica. Resultados: Na análise biomecânica, pode-se observar que o grupo BC apresentou melhor resposta, estatisticamente significante, quando comparado ao CO, no período de 30 dias. Os resultados imunoistoquímicos mostraram na comparação entre os 3 grupos a expressão da OC foi diferente estatisticamente nos períodos de 15 e 60 dias entre os grupos CO e BC; e CO e BI, respectivamente, observando maior expressão para o grupo dos biomateriais aos 15 dias. A expressão de Runx2 foi menor estatisticamente para o grupo BI quando comparado aos demais grupos, no período de 15 dias. Aos 60 dias, a expressão de OPG no grupo BI se apresentou estatisticamente maior que o grupo CO. Nos períodos de 15 e 60 dias, pode-se observar maior expressão de RANK-L... / Objective: To evaluate the effectiveness of bone substitutes in peri-implant defects created in tibia of rabbits which were filled either by blood clot, deproteinized bovine bone mineral (Bio-Oss® / Geistlich) and bovine bone mineral with the addition of 10% collagen porcine origin (Bio-Oss Collagen® / Geistlich), through biomechanics, histology and immunohistochemical analysis of OC, Runx 2, OPG, RANK-L and TRAP proteins. Material and methods: Thirty rabbits received one osteotomy in each tibia using trefine of 6.1 mm in diameter. Subsequently, a spear and helical drills, 2.0 mm, 2.0/3.0 pilot and 3.0 mm were used and 1 implant 4.1 mm/8.5 mm was installed. Bone defects were filled according to the following groups: I-blood clot (CO); II-deproteinized bovine bone mineral (Bio-Oss®) (BI); III-bovine bone mineral with addition of 10% collagen porcine origin (Bio-Oss Collagen®) (BC). Ten animals per period were euthanized at 15, 30 and 60 postoperative days, subsequently biomechanical analysis were performed. Routine histologic processing for histological and immunohistochemistry analysis were also performed. Results: In biomechanics analysis, comparing the different groups for each period can be observed that within 30 days, the BC group showed better biological response statistically proven compared to CO. In immunohistochemistry analysis, the OC expression was statistically significant at 15 and 60 days between CO and BC groups, and between CO and BI groups, respectively, with largest expression for the group of biomaterials. In these same analysed periods, an increased expression of RANK-L can be observed on BI group compared to CO group. OPG expression was statistically significant only iat 60 postoperative days for BI group... (Complete abstract click electronic access below)
159

Regeneração óssea de defeitos circunferenciais criados cirurgicamente ao redor de implantes submersos. Estudo experimental em cães

Rossi, Fabio [UNESP] 06 September 2011 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:32:40Z (GMT). No. of bitstreams: 0 Previous issue date: 2011-09-06Bitstream added on 2014-06-13T19:22:09Z : No. of bitstreams: 1 rossi_f_dr_araca.pdf: 2781899 bytes, checksum: c7a4e989b92a1d7cf3f24753f22ce3c4 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Objetivo: descrever o processo de reparo em defeitos marginais ao redor de implantes submersos 1mm abaixo ou acima da crista óssea. Estudo experimental em cães. Material e Métodos: Em 12 cães labradores, todos os pré-molares inferiores e primeiros molares foram extraídos bilateralmente. Três meses após as extrações, foi realizada a incisão sobre o rebordo e o descolamento dos retalhos de espessura total do lado direito da mandíbula. Foram preparados dois sítios cirúrgicos para instalação de implantes, com a região marginal alargada em 5mm de diâmetro para obtenção de um gap de 0,5 mm na região mesial (defeito pequeno) e um gap de 1,25 mm na região distal (defeito grande). Os parafusos de cobertura foram colocados aos implantes e os retalhos suturados para permitir um processo de cicatrização totalmente submerso. Posteriormente, foram realizados os mesmos procedimentos experimentais no lado esquerdo da mandíbula. O momento da realização dessas cirurgias e as eutanásias foram planejados de forma a se obter biópsias com 5, 10, 20, 30 dias de pósoperatórios. Após a eutanásia, os cortes histológicos foram processados laboratorialmente para análise histomorfométrica. Resultados: Aos 30 dias pós-operatório, os defeitos ósseos apresentaram-se parcialmente preenchidos por osso neoformado em todos os espécimes. A formação óssea ocorreu originando-se a partir da base do defeito e das paredes laterais. Um maior volume de osso neoformado foi observado nos defeitos grandes quando comparado aos pequenos. A maior parte de osso neoformado nos defeitos grandes formou-se entre o décimo e vigésimo dias de pósoperatórios. Entretanto, o contorno do osso neoformado localizou-se a uma distância similar da superfície do implante (aproximadamente 0,4 mm) em ambos os tipos de defeitos, no... / Objective: to describe the healing of marginal defects below or above one millimeter of dimension around submerged implants in a dog model. Material and Methods: In 12 Labrador dogs, all mandibular premolars and first molars were extracted bilaterally. After 3 months of healing, full-thickness flaps were elevated in the edentulous region of the right side of the mandible. Two recipient sites were prepared and the marginal 5 mm were widened to such an extent to obtain, after implant installation, a marginal gap of 0.5 mm at the mesial site (small defect) and of 1.25 mm at the distal site (large defect). Titanium healing caps were affixed to the implants and the flaps were sutured allowing a fully-submerged healing. The experimental procedures were subsequently performed in the left side of the mandible. The timing of the experiments and sacrifices were planned in such a way to obtain biopsies representing the healing after 5, 10, 20, 30 days. Ground sections were prepared and histomorphometrically analyzed. Results: The filling of the defect with newly formed bone was incomplete after one month of healing in all specimens. Bone formation occurred from the base and the lateral walls of the defects. A larger volume of new bone was formed in the large compared to the small defects. Most of the new bone at the large defect was formed between the 10 and the 20-day period of healing. After one month of healing, the outline of the newly formed bone was, however, located at a similar distance from the implant surface (about 0.4 mm) at both defect types. Only minor newly formed bone in contact with the implant, starting from the base of the defects, was seen at the large defects (about 0.8 mm) while a larger amount was detected at the small defects (about 2.2 mm). Conclusion: Marginal defects around titanium... (Complete abstract click electronic access below)
160

Avaliação do padrão de reparação óssea ao redor de implantes submersos: estudo experimental em cães

Pantani, Fabio [UNESP] 08 September 2011 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:32:40Z (GMT). No. of bitstreams: 0 Previous issue date: 2011-09-08Bitstream added on 2014-06-13T19:22:10Z : No. of bitstreams: 1 pantani_f_dr_araca.pdf: 727767 bytes, checksum: e4d353c863a247e47759cfbc20bfed46 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Objetivo: estudar as fases iniciais da regeneração óssea de implantes instalados sobre a crista óssea alveolar desdentada. Material e Métodos: Em 12 cães labradores, foram extraídos bilateralmente todos os pré-molares inferiores e primeiros molares. Após 3 meses de regeneração, foi realizada a incisão sobre o rebordo alveolar desdentado do lado direito da mandíbula e descolamento do retalhos de espessura total. Foram instalados dois implantes e finalizado com a suturas dos retalhos para permitir a regeneração totalmente submersa. Posteriormente, foram realizados os mesmos procedimentos experimentais no lado esquerdo da mandíbula. Os sacrifícios dos animais foram planejados de forma a obter biópsias com pós-operatórios de 5, 10, 20 e 30 dias. Um implante de cada lado da mandíbula foi processado laboratorialmente para cortes histológicos em tecido mineralizado (inclusão em resina) e outro para cortes histológicos em tecido desmineralizado (inclusão em parafina). Resultados: Foi observada apenas uma reação celular importante ao redor do implante no compartimento da medula óssea. Observou-se a formação de matriz óssea provisória e, posteriormente, osso esponjoso ao redor e em contato com o implante. O contato osso-implante melhorou durante os períodos de regeneração avaliados. Conclusão: Com este estudo pode-se mostrar que a preparação do sítio cirúrgico e a instalação do implante produziram reação celular evidente no osso circunjacente. No compartimento da medula óssea, a aposição de matriz óssea provisória e formação de osso esponjoso ocorreram seqüencialmente durante o primeiro mês de pós- operatório. Na região em que o osso apresentou contato com a superfície do implante, os processos de remodelação óssea (reabsorção e aposição óssea) ocorreram através da intervenção das BMUs (Bone Multicellular Units) / Objective: the purpose of the present study was to evaluate the early phases of bone response to implants installed in edentulous alveolar bony crest. Material & Method: In 12 Labrador dogs, all mandibular premolars and first molars were extracted bilaterally. After 3 months of healing, full-thickness flaps were elevated in the edentulous region of the right side of the mandible. Two implants were installed and the flaps were sutured to allow a fully-submerged healing. The experimental procedures were subsequently performed in the left side of the mandible. The timing of the experiments and sacrifices were planned in such a way to obtain biopsies representing the healing after 5, 10, 20, 30 days. One implant from each side of the mandible was processed for ground sections and the other for paraffin sections. Results: only an important cellular reaction was observed around the implant in the bone marrow compartment. Provisional matrix and, subsequently, woven bone were formed around and in contact with the implant. Bone-to-implant contact improve duign the healing period. Conclusions: In conclusion, the present experiment showed that site preparation and implant placement produced an evident cellular reaction within the surrounding bone. In the bone marrow compartment, provisional matrix apposition and woven bone formation occurred sequentially during the first month of healing. Where mineralized bone was in contact with the implant surface, bone remodeling processes (bone resorption and apposition) occurred through the intervention of BMUs (Bone Multicellular Units)

Page generated in 0.0554 seconds