• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 552
  • 114
  • 20
  • 18
  • 18
  • 17
  • 17
  • 11
  • 10
  • 9
  • 8
  • 4
  • 3
  • 2
  • 2
  • Tagged with
  • 739
  • 739
  • 508
  • 475
  • 153
  • 135
  • 122
  • 109
  • 90
  • 76
  • 76
  • 74
  • 72
  • 70
  • 60
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
191

Alterações eletrocardiográficas em cirugias para a colocação de implantes dentários sob anestesia local e pré-medicação ansiolítica\" / Electrocardiographic changes during oral implant surgeries under local anesthesia and sedative premedication

Marcelo Munhóes Romano 12 September 2006 (has links)
A significância clínica dos achados eletrocardiográficos para pacientes sem histórico de doença cardiovascular é pequeno ou inexistente, porém em pacientes com doenças cardiovasculares poderia justificar o uso de monitoração contínua, incluindo o uso de eletrocardiograma além de terapêutica comportamental ou medicamentosa para certos procedimentos odontológicos com níveis de estresse moderado a elevado. Este estudo teve como objetivo a avaliação das alterações eletrocardiográficas em cirurgias para a colocação de implantes dentários sob anestesia local com cloridrato de lidocaína 2% associado a epinefrina, com uso de pré-medicação ansiolítica com 15mg de midazolam. O estudo foi realizado em 15 pacientes ASA I, com necessidade de implantes dentários, bilaterais em mandíbula. O estudo foi comparativo com placebo administrado aleatoriamente, duplo cego 1 hora antes ao procedimento. O eletrocardiograma registrou 12 derivações estáticas a cada 2 minutos e o registro da derivação D2 de maneira contínua, avaliando o comportamento morfológico da onda eletrocardiográfica e a presença de arritmias durante o experimento. Não foram encontradas diferenças significantes entre os grupos estudados. Quando comparamos o comportamento dos parâmetros eletrocardiográficos durante as fases do procedimento, observamos diferenças estatística (p<0,01) para a freqüência cardíaca, amplitude da onda P e duração dos intervalos RR e QTc para o grupo com sedação. Foram observadas arritmias em 53,3% dos pacientes. As arritmias encontradas foram a taquicardia e a bradicardia sinusal, as extrasístoles supraventriculares, ventriculares e extrasístole atrial bloqueada, em ambos os grupos de maneira semelhante, com maior incidência nas fases inicio e perfuração. As arritmias encontradas foram consideradas de baixo risco para pacientes sem compromeitmento sistêmico. Concluiu-se que o uso de 15mg de midazolam não apresentou diferença quando comparado ao placebo. A fase incisão apresentou maiores valores de freqüência cardíaca e amplitude da onda P e menores para duração dos intervalos RR e QTc. As arritmias mais frequentes foram as extra-sístoles e a taquicardias sinusais. / The clinical significance of eletrocardiographic evalution in patients without cardiovascular disease is very small. However, continuous monitoring using electrocardiogram and anxiety control methods, such as behaviour manegement technique and premedication, may be justified in patients with cardiovascular disease undergoing dental procedures that cause stress. The aim of this study was to evaluate the electrocardiographic alterations that occur during oral implant surgeries under local anesthesia with a 2% lidocaine hydrochloride,1: 100,000 epinephrine and midazolam sedation. One hour prior to surgery, patients were given premedication (15 mg midazolam or placebo). The subjects of this study were 15 ASA I patients, who needed bilateral implant surgery on the lower jaw. A total of 30 implant surgeries were evaluated in a double blind study. Electrocardiographic tracing the 12 static leads every two minutes and Lead II was registered in a continuous manner during sugery. Automatic measurement of the following electrocardiographic parameters were also performed: heart rate (HR), duration and amplitude of P wave, ST segment depression, duration of PR segment, QRS complex, and duration of RR, QT and QTc intervals. No statistically significant differences were found between the groups, midazolam and placebo. Howerver, analysis of the data at different stages of implant surgery showed significant difference at 1% level in relation to heart rate and, amplitude of P wave, duration of RR and QTc intervals in the midazolam group. Cardiac arrhythmias were found in 53,3% of the patients. The following cardiac arrhythmias were detected: sinusal tachycardia and bradycardia, sinusal arrhythmia, supraventricular extrasystole, ventricular extrasystole, and blocked atrial extrasystole. Arrhythmias occurred, most frequently, at the begining of implant surgery and during drilling, in a similar pattern in both groups. The arrhythmias detected in these patients were considered low risk factors in patients with no systemic alterations. In conclusion, the use of 15 mg of midazolam seemed to be no different from placebo in this study. During incision, we observed the highest heart rate values and amplitude of P wave and the lowest RR and QTc intervals. Extrasystole and sinusal tachycardia were the most frequent arrhythmias detected in these patients.
192

Análise de corrosão e fratura de implantes/componentes protéticos de titânio comercialmente puro, após serem submetidos a ciclos de fadiga em um meio fluoretado com diferentes Ph

Sartori, Rafael [UNESP] January 2006 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:03Z (GMT). No. of bitstreams: 0 Previous issue date: 2006Bitstream added on 2014-06-13T18:57:07Z : No. of bitstreams: 1 sartori_r_me_arafo.pdf: 1051874 bytes, checksum: cefcb24c1a056b34cdd58078fbe9390f (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Universidade Estadual Paulista (UNESP) / Atualmente o titânio é empregado como biomaterial devido sua biocompatibilidade e resistência à corrosão, entretanto os íons fluoretos são efetivos no processo de corrosão. O objetivo deste estudo foi analisar a influência de um meio fluoretado com diferentes pH nas propriedades mecânicas e na resistência à corrosão dos conjuntos implantes/componentes protéticos à base de Ti c.p., a partir dos testes de ciclagem mecânica, microscopia eletrônica de varredura (MEV) e dureza. Foram simulados cinco anos de uso regular de meios de higiene oral com conteúdo de 1500 ppm de NaF, com dois diferentes pH, mediante imersão das amostras nesse meio durante 184 horas. As amostras foram testadas num durômetro Micromet 2001. Os dados dos testes de dureza foram analisados pelo teste de Wilcoxon, demonstrando que as amostras sofreram influência negativa na dureza após a ação dos íons fluoreto. Entretanto, essa influência não ocorreu nos testes de ciclagem mecânica realizados em uma máquina de ensaios universais MTS-810, fixada a 100.000 ciclos, 15Hz e programada com força de fadiga a 150 N. Pela análise de MEV e EDS não foi contatado evidências de corrosão na superfície das amostras após ação de íons fluoretos, nem incorporação de íons fluoretos sobre a superfície dos conjuntos. Concluiu-se que a concentração de flúor e o pH das soluções não exerceram influência nas propriedades mecânicas e na resistência à corrosão. / Titanium has been widely used as biomaterial owing to its excellent corrosion resistance, mechanical properties and biocompatibility. However, it has been reported that fluoride-containing environments can attack titanium. The aim of this study was evaluated fluoride environments influence with different pH values in the implant/abutment sets. The implants were separated into 3 groups containing 7 implants/brand: one was submerged in acid fluoride environment (NaF 1500ppm 184h pH 5.3), one in neutral fluoride environment (NaF 1500ppm 184h pH 7.4), and other group in distillated water, simulating five years of dental hygiene. Hardness and surface texture were evaluated before and after fluoride exposition by Vickers method (500gf 30s) and scanning electron microscopy (SEM), respectively. The fatigue test was performed with 100.000 load cycles, 15 Hz and 150 N. There was decrease in hardness in implants submitted to the fluoride environment. SEM and EDS evaluation showed dark stains in all implants, irrespective of fluoride pH, resulting from pitting corrosion process. All sets supported the fatigue test until 100.000 load cycles. The results demonstrated that fluoride environment there was no influence in mechanical properties and corrosion resistence of the implant/abutment sets.
193

Análise histológica, imunoistoquímica e morfométrica de biópsias de tecidos ósseo de pacientes hipertensos compensados / Histological, molecular and morphometric analysis of bone tissue biopsies in compensated hypertensive patients

Fabris, André Luis da Silva [UNESP] 28 July 2016 (has links)
Submitted by ANDRÉ LUÍS DA SILVA FABRIS null (andre.fabris@hotmail.com) on 2016-08-18T20:52:14Z No. of bitstreams: 1 Defesa_Andre_12.08.16.pdf: 6198533 bytes, checksum: 628414a513735df84a437ab8c7c82233 (MD5) / Approved for entry into archive by Ana Paula Grisoto (grisotoana@reitoria.unesp.br) on 2016-08-22T18:17:44Z (GMT) No. of bitstreams: 1 fabris_als_dr_araca_par.pdf: 253349 bytes, checksum: 0fdc6afd35eba2551f38a3b77ac48711 (MD5) / Made available in DSpace on 2016-08-22T18:17:44Z (GMT). No. of bitstreams: 1 fabris_als_dr_araca_par.pdf: 253349 bytes, checksum: 0fdc6afd35eba2551f38a3b77ac48711 (MD5) Previous issue date: 2016-07-28 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Objetivo: O presente estudo objetivou avaliar as características morfométicas, histológicas e imunoistoquímicas do tecido ósseo coletado de pacientes portadores de hipertensão arterial sistêmica compensada pelo uso de medicamentos antagonistas do sistema renina-angiotensina-aldoesterona (SRAA). Materiais e Métodos: Trinta pacientes com indicação para reabilitação por meio de implantes instalados na região posterior de mandíbula foram divididos em dois grupos, seguindo os critérios de inclusão e exclusão previamente estabelecidos. O primeiro grupo não apresentava alterações sistêmicas (GSA) e não fazia uso de qualquer medicação e, o segundo grupo foi composto por pacientes hipertensos diagnosticados e medicados por antagonistas do SRAA (GAS). Durante o procedimento cirúrgico para instalação dos implantes osseointegráveis com superfície texturizada, foram coletados blocos ósseos por meio de biópsia com broca trefina de 3,0mm de diâmetro nos locais de instalação dos implantes. As biópsias coletadas foram separadas para avaliação por microtomografia computadorizada, sendo avaliados os seguintes parâmetros: volume ósseo (BV/TV), percentual de volume ósseo (BV/TV), espessura de trabéculas (Tb.Th), número de trabéculas (Tb.N), separação entre as trabéculas (Tb.S) e porosidade total (Po-tot). Também foi realizada a análise dos cortes histológicos corados por hematoxilina e eosina, bem como a avaliação imunoistoquímica de proteínas que caracterizam as células da linhagem osteoblástica: Runx2, Osteopontina e Osteocalcina. Resultados: Para todos os parâmetros analisados (BV, BV/TV, Tb.Th, Tb.N, Tb.S e Po-tot), houve similaridade na comparação entre os grupos GAS e GSA (p<0,05, teste t). As imunomarcações para osteopontina e osteocalcina mostraram-se semelhantes nos dois grupos. Vale destacar importante marcação observada no grupo GAS para o fator de transcrição Runt 2 (Runx2), em comparação a marcação da mesma proteína no grupo GSA. Além disso, a biologia do tecido ósseo do ponto de vista histológico foi semelhante nos dois grupos. Conclusões: Foi possível concluir que indivíduos hipertensos tratados com antagonistas do SRAA apresentam grande similaridade óssea microestrutural e também celular/protéica aos indivíduos normotensos. / Objectives: This study aimed to evaluate the morphometric characteristics, histological and immunohistochemical bone tissue collected from patients with hypertension offset by the use of drugs antagonists of the renin angiotensin system. Material and Methods: 30 patients referred for rehabilitation with implants placed in the posterior mandible were divided into two groups, following the criteria of inclusion and exclusion previously established. The first group showed no systemic changes (GSA) and did not use any medication and the second group was composed of diagnosed hypertensive patients treated by RAAS (GAS) antagonists. During the procedure for installation of dental implants with textured surface, they were collected bone blocks through biopsy trephine drill 3.0mm diameter implants in the installation sites. The collected biopsies were separated fo evaluatio by microtomography, being evaluated the following parameters: bone volume (BV / TV), trabecular thickness(Tb.Th), trabecular number (Tb.N), separation of the trabecular (Tb.S) and total porosity (Po-tot). Also the analysis of histological sections stained with hematoxylin and eosin staining was performed as well a the immunohistochemical evaluation of proteins that characterize the cells of osteoblast lineage: Runx2, osteopontin and osteocalcin. Results: For all parameters (BV, BV / TV, Tb.Th, Tb.N, Tb.S and E-tot) were similar in the comparison between GAS and GSA (p> 0.05, t test). The biology of bone tissue to analyze by immunohistochemistry presented similar results in both groups, with markings scores in ordinal qualitativ analysis for transcription factor related to Runt 2 (Runx2) GSA (light) and GAS (moderate), osteopontin (OP) GSA (mild to moderate) and GAS (moderate to intense), osteocalcin (OC) GSA (intense) and GAS (moderate). Furthermore, the biology of bone tissue was histologically similar in both groups. Conclusions: Therefore, it was concluded that hypertensive subjects treated with renin-angiotensin system antagonists have great bone microstructural similarity and also cell/protein to normotensive individuals.
194

Avaliação da estabilidade primária de implantes instalados em cavidades confeccionadas por meio do ultrassom cirúrgico e instrumentos rotatórios convencionais: Estudo in Vitro / Assessment of the primary stability of dental implants prepared cavities with piezosurgery and conventional rotatory instruments: In Vitro study

Silva, Leonardo de Freitas [UNESP] 17 October 2016 (has links)
Submitted by LEONARDO DE FREITAS SILVA null (leonardofreitas86@gmail.com) on 2016-10-20T13:26:49Z No. of bitstreams: 1 Dissertação de mestrado- reapresentação 1.pdf: 1472109 bytes, checksum: e157f95a9ba34bce0469c51f091af276 (MD5) / Approved for entry into archive by Juliano Benedito Ferreira (julianoferreira@reitoria.unesp.br) on 2016-10-26T17:52:37Z (GMT) No. of bitstreams: 1 silva_lf_me_arafo.pdf: 1472109 bytes, checksum: e157f95a9ba34bce0469c51f091af276 (MD5) / Made available in DSpace on 2016-10-26T17:52:37Z (GMT). No. of bitstreams: 1 silva_lf_me_arafo.pdf: 1472109 bytes, checksum: e157f95a9ba34bce0469c51f091af276 (MD5) Previous issue date: 2016-10-17 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / A estabilidade primária de implantes dentários corresponde a um fenômeno mecânico relativo à qualidade ou quantidade óssea, ao tipo de implante e a técnica de instalação. O objetivo deste trabalho foi avaliar o tempo de fresagem, aquecimento dos sítios fresados e a estabilidade dos implantes instalados em cavidades realizadas com ultrassom cirúrgico e instrumentos rotatórios. Foram realizadas 64 cavidades em 04 blocos de poliuretano simulando as densidades de ossos tipo I, II, III e IV. A temperatura da superfície do bloco nos leitos foi medida durante a fresagem. A estabilidade dos implantes foi mensurada por meio do torque de inserção, de remoção e frequência de ressonância. O implante cilíndrico TitaOss 3,75 x 11 mm foi instalado em todas as cavidades. Os resultados mostraram maior tempo e temperatura para o grupo em que foi usado o ultrassom. Quanto à estabilidade primária não houve diferença significante entre os grupos estudados. Pôde-se concluir que a estabilidade primária dos implantes não foi influenciada pelos métodos de fresagem utilizados e que o ultrassom cirúrgico necessitou de mais tempo e gerou mais calor do que o instrumento rotatório para o preparo das cavidades. / The primary stability of dental implants corresponds to a mechanical phenomenon related to bone quality or quantity, type of implant and installation technique. The objective of this study was to evaluate the time of drilling, heating drilled sites and stability of implants placed in cavities made with piezosurgery and rotary instruments. Polyurethane blocks were used simulating the densities of bone type I, II, III and IV. The surface temperature of the block was measured in the cavity during drilling, and recorded the highest temperature variation. The stability of the implants was measured with a torque insertion, torque of removal and resonance frequency. The cylindrical implant TitaOss 3.75 x 11 mm was used in all cavities. The results showed greater time and temperature for the group that was used piezosurgery. The primary stability was no significant difference between groups. It could be concluded that implant primary stability was not influenced by the used methods and piezosurgery took more time and generated more heat than the conventional rotatory instruments to prepare the cavities.
195

Análise da distribuição das tensões em próteses protocolo mandibulares com estruturas fresadas por CAD/CAM e confeccionadas pela técnica convencional: análise pela fotoelasticidade e extensometria / Analysis of stress distribution in full-arch fixed mandibular prosthesis with structures made with the CAD/CAM technology and with the conventional technique: evaluation through photoelastic and strain gauge analysis

Medeiros, Rodrigo Antonio de [UNESP] 12 December 2016 (has links)
Submitted by RODRIGO ANTÔNIO DE MEDEIROS null (rodrigomedeiros88@hotmail.com) on 2017-01-17T18:59:53Z No. of bitstreams: 1 Tese_Rodrigo Medeiros.docx: 4055404 bytes, checksum: 8420d48d6379115c0945c7b9f391bbc6 (MD5) / Rejected by LUIZA DE MENEZES ROMANETTO (luizamenezes@reitoria.unesp.br), reason: Solicitamos que realize uma nova submissão seguindo as orientações abaixo: Incluir o número do processo de financiamento nos agradecimentos da dissertação/tese. A versão final da dissertação/tese deve ser submetida no formato PDF (Portable Document Format). O arquivo PDF não deve estar protegido e a dissertação/tese deve estar em um único arquivo, inclusive os apêndices e anexos, se houver. Por favor, estas informações e realize uma nova submissão. Agradecemos a compreensão. on 2017-01-20T15:26:30Z (GMT) / Submitted by RODRIGO ANTÔNIO DE MEDEIROS null (rodrigomedeiros88@hotmail.com) on 2017-01-20T21:34:08Z No. of bitstreams: 1 Tese_Rodrigo Medeiros.pdf: 2572700 bytes, checksum: 14ceeb89edad876baa95811c229c59dd (MD5) / Approved for entry into archive by LUIZA DE MENEZES ROMANETTO (luizamenezes@reitoria.unesp.br) on 2017-01-23T19:00:09Z (GMT) No. of bitstreams: 1 medeiros_ra_dr_araca.pdf: 2572700 bytes, checksum: 14ceeb89edad876baa95811c229c59dd (MD5) / Made available in DSpace on 2017-01-23T19:00:09Z (GMT). No. of bitstreams: 1 medeiros_ra_dr_araca.pdf: 2572700 bytes, checksum: 14ceeb89edad876baa95811c229c59dd (MD5) Previous issue date: 2016-12-12 / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / O objetivo desse estudo foi avaliar a distribuição de tensão, por meio dos métodos fotoelástico e extensometria, em próteses protocolo mandibulares (tipo Branemärk) com infraestruturas confeccionadas com diferentes materiais e técnicas, sob força de compressão. Foi confeccionado um modelo fotoelástico de uma mandíbula edêntula que recebeu cinco implantes 4x11 mm hexágono externo entre os forames mentonianos. Os grupos foram divididos em: Grupo I - infraestrutura fundida em níquel-cromo com revestimento oclusal em resina acrílica (n=7); Grupo II - infraestrutura fundida em níquel-cromo com revestimento oclusal em cerâmica (n=7); Grupo III - infraestrutura fresada em Zircônia estabilizada por óxido de ítrio com revestimento em cerâmica (n=7). Inicialmente, foi realizado o teste da fotoelasticidade e, posteriormente, a extensometria. Pela metodologia da fotoelasticidade, com auxílio de uma máquina de ensaio universal (EMIC) foram aplicadas cargas axiais de 70 N na região do implante mais anterior, entre os incisivos, e no centro do primeiro molar de cada lado. Por meio de imagens fotográficas e com o auxílio do programa Adobe Photoshop CS6, as imagens foram analisadas de acordo com o número de franjas de alta intensidade nos grupos testados. Para a metodologia da extensometria, as cargas foram aplicadas da mesma maneira da metodologia da fotoelasticidade e a medição das tensões foi realizada em duas regiões distintas. Para a primeira região, dois extensômetros elétricos de resistência foram posicionados horizontalmente na região mesial e distal dos cinco implantes, diretamente sobre a crista marginal do modelo fotoelástico. Para a segunda região, a resina fotoelástica foi removida da superfície vestibular e lingual de cada implante, sendo mantida1 mm de resina intacta, onde os extensômetros foram fixados verticalmente. Foram realizados os mesmos testes de compressão descritos anteriormente. Os valores de tensão registrados foram agrupados em tabelas e submetidas à análise de variância (ANOVA) dois fatores e ao teste de Tukey com significância de 5%. Os resultados das duas metodologias demonstraram menores valores de tensão para o Grupo I, quando comparado aos demais grupos. É possível concluir que as próteses protocolo com infraestrutura fundida em metal e revestimento oclusal acrílico demonstraram melhores resultados biomecânicos. / This study aimed to evaluate the stress distribution in full-arch fixed mandibular prosthesis (Branemärk type) with infrastructure made of different materials and techniques, and under compressive force, through photoelastic and strain gauge analysis. A photoelastic cast of an edentulous jaw was fabricated and received five external hexagon implants (4x11mm) between the mental foramen. The groups were divided into: Group I - Nickel-Chrome fused infrastructure with acrylic resin occlusal coating; Group II - Nickel-Chrome fused infrastructure with ceramic occlusal coating; Group III - Yttria-stabilized zirconia fused infrastructure with ceramic coating. First, the photoelastic analysis was performed and later the strain gauge analysis. A force of 70 N was applied by using a testing machine (EMIC) in the region of the most anterior implant, between incisors, and in the center of the first molar on each side. The images were analyzed by a blinded evaluator through images and by using Adobe Photoshop CS6, according to the number of high intensity fringes in each group. Regarding the strain gauge analysis, the stress measure was performed in two distinct regions. For the first region, two resistance strain gauges were placed horizontally in the mesial and distal regions of the five implants, directly on the marginal ridge of the photoelastic cast. For the second region, the photoelastic resin was removed on the buccal and lingual surfaces of each implant, leaving 1 mm of intact resin, where the strain gauges were placed vertically. The same compression tests described above were carried out. Data were submitted to two-way ANOVA and to the Tukey post-hoc test with 5% level of significance. The results of both methods showed lower stress values for Group I, when compared to other groups. It can be concluded that when rigid materials are used for infrastructure fabrication, the esthetic coating influences the load generated on the marginal bone around the implant. The ceramic coating showed less satisfactory results. / FAPESP: 2014/14088-0 / FAPESP: 2014/11605-3
196

Avaliação da prevalência das doenças peri-implantares e do sucesso e sobrevivência de implantes osseointegrados com 8 a 10 anos de função /

Marcantonio, Claudio. January 2014 (has links)
Orientador: Daniela Leal Zandim Barcelos / Co-orientador: / Banca: José Eduardo Cezar Sampaio / Banca: Francisco de Assis Molo Junior / Banca: Rafael Silveira Faeda / Banca: Waldyr Antonio Jorge / Resumo: O propósito deste estudo retrospectivo foi verificar as taxas de sucesso e sobrevivência de implantes osseointegrados no longo prazo, assim como determinar a prevalência de doenças peri-implantares e identificar possíveis fatores de risco associados à ocorrência da peri-implantite. A amostra foi constituída de 50 pacientes parcialmente desdentados que realizaram reabilitações sobre implantes osseointegrados no período de 2003 a 2005. As avaliações incluíram a coleta de informações demográficas, sistêmicas e comportamentais, além de exames clínicos e radiográficos para avaliação da condição periodontal e peri-implantar. Uma análise multivariada foi adotada para identificar possíveis preditores de risco para a periimplantite. Um total de 211 implantes foram instalados nestes pacientes. Cinco implantes foram perdidos e 9 implantes encontravam-se submersos, ou seja, sem função. Assim, 197 implantes em 48 pacientes foram avaliados clinicamente. A prevalência de mucosite foi de 77,1% a nível de paciente e 52,3% a nível de implante. A peri-implantite foi diagnosticada em 25 implantes em 14 pacientes. As taxas de sucesso e de sobrevivência encontradas foram de 82% e de 97,6%, respectivamente. A presença de osteoporose (OR = 2,87) e a presença de sangramento à sondagem (SS) de boca toda ≥ 30% dos sítios (OR = 8,03) foram variáveis relacionadas ao indivíduo significativamente associadas com maior ocorrência de periimplantite. A presença de placa visível (OR = 4,45) e a presença de sítios com profundidade de sondagem (PS) ≥ 4 mm (OR = 4,47) foram variáveis relacionadas ao implante significativamente associadas com maior ocorrência de peri-implantite. Apesar da alta taxa de sobrevivência no longo prazo, foi observada uma alta prevalência de mucosite e a peri-implantite foi diagnosticada em 12,7% dos implantes e 29,2% dos pacientes avaliados...(Resumo completo, clicar acesso eletrônico abaixo) / Abstract:The aim of the present study was to verify the long-term success and survival rates of osseointegrated dental implants, as well to determine the prevalence of peri-implant disease, and to identify potential risk factors associated to the occurrence of peri-implantitis. The sample was comprised of 50 patients who had their implant-supported rehabilitation concluded between the years of 2003 and 2005. Evaluations included the gathering of demographic, systemic and behavioral information, as well as radiographic and clinical records for the assessment of periodontal and peri-implant conditions. Multivariate analysis was employed to identify potential risk factors related to the occurrence of peri-implantitis. A total of 211 implants were installed, out of which 5 were lost and 9 were submerged, that is, nonfunctioning. Thus, 197 implants in 48 patients were clinically evaluated. The presence of osteoporosis (OR = 2,87) and the presence of full-mouth BOP scores ≥ 30% of sites (OR = 8,03) were variables significantly associated with a higher occurrence of peri-implantitis, among the subjects. At the implant level, the presence of visible plaque (OR = 4.45) and the presence of sites with probing depth (PD) ≥ 4 mm (OR = 4.47) were variables significantly associated with a higher occurrence of peri-implantitis. Mucositis prevalence was 77.1% and 52.3%, at subject and implant level, respectively. Periimplantitis was diagnosed in 25 implants (12.7%) and 14 patients (29.2%). Success and survival rates were 82% and 97.6%, respectively. Our results suggest that subjects with osteoporosis and with full-mouth BOP scores ≥ 30% of the sites, as well as implants with visible plaque and sites with PD ≥ 4 mm, are more susceptible to peri-implantitis. / Doutor
197

Carbono tipo diamante em componentes de implantes dentários: avaliação das propriedades antimicrobianas e de adesão de Escherichia coli /

Maquera Huacho, Patricia Milagros. January 2014 (has links)
Orientador: Denise Madalena Palomari Spolidorio / Banca: Luis Geraldo Vaz / Banca: Rafael Silveira Faeda / Resumo: O estudo de filmes de Carbono tipo Diamante é objeto de pesquisas devido às suas diferentes propriedades incluindo propriedades antibacterianas. No tratamento reabilitador com implantes, podem ocorrer complicações, proporcionando a infiltração de microrganismos orais para a interface Implante-Componente protético. O objetivo deste estudo foi avaliar propriedades de molhabilidade e energia livre de superfície a partir dos valores do ângulo de contato; propriedades antimicrobiana, de bioadesão e citotoxicidade de discos de titânio recobertos com DLC. Escherichia coli foi mantida em meio BHI a 37ºC por 3 h e 24 h para teste antimicrobiano. Para adesão, os discos foram mantidos em cultura de E. coli por 90 minutos a 37ºC e 20 minutos em ultrassom. A capacidade de prevenção na migração de bactérias para o interior da interface Implante-Componente protético foi realizado em implantes Hexágono Externo, conectados com torque de 32N e deixados em contato com E. coli por 24h, e Reação em Cadeia da Polimerase semi-quantitativo foi realizado para confirmação da esterilidade da técnica. Foram quantificados em UFC/mL em BHI Ágar para o teste antimicrobiano, adesão e infiltração bacteriana. Para citotoxicidade foi utilizado queratinócitos humanos (HaCat) cultivados em meio DMEM mantidos em atmosfera com 5% de CO2 a 37°C e avaliados pelo teste colorimétrico MTT. Os resultados de molhabilidade, teste antimicrobiano, teste de adesão e Infiltração bacteriana não apresentaram diferença estatisticamente significante entre os grupos. As superfícies de titânio e recobertas com DLC apresentaram uma leve diminuição na viabilidade celular com diferença estatisticamente significante ao grupo controle. O DLC apresenta-se como material biocompatível com leve grau de citotoxicidade que não modifica as propriedades de superfície, não apresenta propriedades antimicrobianas... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The study of DLC films is the subject of research due to their different properties including antibacterial properties. Rehabilitator in implant treatment, complications may occur, providing the infiltration of oral microorganisms for implant- abutmente interface. The aim of this study was to evaluate properties and wetting surface free energy from the values of the contact angle; antimicrobial properties bioadhesion and cytotoxicity of titanium discs coated with DLC. Escherichia coli was maintained on BHI at 37 ° C for 3 h and 24 h for antimicrobial test. For adhesion test, the discs were maintained in culture of E. coli for 90 minutes at 37 ° C and 20 minutes inside ultrasound. The ability to prevent the migration of bacteria into the implant - abutment interface was performed in dental implants External Hexagon connected with a torque of 32N and left in contact with E. coli for 24 h, and Polymerase Chain Reaction semi -quantitative was performed to confirm the sterility of the technique. Were quantified in CFU / ml in BHI agar for antimicrobial test, bacterial adhesion and infiltration. Cytotoxicity was performed using human keratinocytes ( HaCaT ) cultured in DMEM maintained in an atmosphere of 5% CO2 at 37 ° C and evaluated by the MTT colorimetric assay. The results of wettability, antimicrobial test, adhesion test and bacterial infiltration showed no statistically significant difference between the test groups. The surfaces of titanium and coated with DLC showed a slight decrease in cell viability with a statistically significant difference to the control group. The DLC is presented as biocompatible material with mild cytotoxicity without changing the surface properties, has no antimicrobial properties, does not interfere with bacterial adherence for E. coli and do not inhibit bacterial infiltration into the implant-abutment interface. / Mestre
198

Estudo comparativo do Biogran® e Endobon® associados a implantes com defeitos periimplantares /

Carvalho, Helen Ramon Esper de. January 2015 (has links)
Orientador: Osvaldo Magro Filho / Banca: Francisley Ávila de Souza / Banca: Celso Koogi Sonoda / Banca: Paulo Domingos Ribeiro Junior / Banca: Camila Tirapelli / Resumo: Introdução: A utilização de biomateriais em reconstruções para implantodontia tem sido amplamente discutida nos últimos anos. Proposição: O objetivo deste trabalho foi analisar o comportamento biológico do vidro bioativo (Biogran®) e do osso bovino (Endobon®) durante o processo de osseointegração associados a implantes com defeitos periimplantares em tíbias de rato. Material e método: Foram instalados 75 implantes na tíbia esquerda de 75 ratos Wistar machos. Os implantes foram divididos em três grupos experimentais. No Grupo 1 (Controle) foi provocado um defeito periimplantar monocortical circular e os implantes foram inseridos e deixados apenas com coágulo. No Grupo 2 os implantes foram inseridos com o mesmo defeito ósseo e o espaço preenchido com Biogran® e no Grupo 3 o espaço entre osso e implante foi preenchido com Endobon®. Os animais foram submetidos à eutanásia aos 14 e 42 dias e realizaram-se as análises histológica, histométrica (porcentagem de extensão linear de contato osso-implante - BIC e área óssea - BA), imunoistoquímica (expressão das proteínas osteocalcina - OC e osteopontina - OPN) e biomecânica (torque reverso). Resultados: Histologicamente todos os implantes encontraram-se osseointegrados. Não foram observadas diferenças estatisticamente significantes nos valores de torque reverso (p> 0,05) aos 42 dias. Para BIC, aos 14 dias foi de 8,29; 15,04; e 16,20%, para os grupos 1, 2 e 3, respectivamente. Aos 42 dias, os valores médios de BIC foram 30,84; 33,13; e 13,93% para os mesmos grupos, demonstrando que não houveram diferenças estatísticas entre grupos, porém com respostas diferentes entre períodos. Para a quantificação de formação óssea por área (BA), a resposta entre grupos difere. A resposta da BA média do Grupo 1 (18,75%) não difere da resposta média do Grupo 3 (21,62%). Porém, difere... / Abstract: Introduction: The use of biomaterials in reconstructions for dental implants has been widely discussed in recent years. Proposition: The aim of this work was to analize the biological behavior of the bioactive glass (Biogran®) and bovine bone (Endobon®) during the osseointegration process associated with implants with peri-implant defects in rat tibia. Material and Methods: 75 implants were installed in the left tibia of 75 male Wistar rats. The implants were divided into three experimental groups. In Group 1 (Control) was caused monocortical circular peri-implant defect and the implants were inserted and left only with clot. In Group 2 implants were inserted with the same bone defect and the space filled with Biogran® and in Group 3 the space between bone and implant was filled with Endobon®. The animals were euthanized at 14 and 42 days and there were the histological analysis, histometric (percentage of linear extension bone-implant contact - BIC and bone area - BA), immunohistochemistry (expression of the proteins osteocalcin - OC and osteopontin - OPN) and biomechanics (reverse torque). Results: Histologically all implants were osseointegrated. No statistically significant differences were observed in the values of reverse torque (p> 0.05) at 42 days. For BIC, at 14 days was 8.29; 15.04; and 16.20% for the groups 1, 2 and 3, respectively. After 42 days, the BIC values were 30.84; 33.13; and 13.93% for the same groups, demonstrating that there were no statistical differences between groups, but with different responses between periods. For the quantification of bone formation per area (BA), the response differs between groups. The average BA response in Group 1 (18.75%) did not differ from the average Group 3 response (21.62%). However, different from Group 2 (34.73%). The immunohistochemical results were analyzed by Qualitative... / Doutor
199

Estudo das tensões em próteses sobre implantes esplintadas : análise pelo método da fotoelasticidade /

Villa, Luiz Marcelo Ribeiro. January 2013 (has links)
Orientador: Eduardo Piza Pellizzer / Banca: Marcelo Coelho Goiato / Banca: Stefan Fiuza de Carvalho Dekon / Banca: Regina Tamaki / Banca: Sandra Lúcia Dantas de Moraes / Resumo: Propósito: O objetivo deste estudo foi avaliar a influência da esplintagem e de diferentes comprimentos de implantes na distribuição de tensões em próteses implantossuportadas, sob carregamento axial e oblíquo, por meio do método da fotoelasticidade. Materiais e métodos: Um total de 05 modelos em resina fotoelástica foi confeccionado com diferentes situações propostas, realizaram-se 400 aplicações de carga para análise. As tensões foram consideradas de forma quantitativa e qualitativa utilizando um método randomizado e simples cego. A reprodutibilidade do estudo foi avaliada usando o coeficiente de correlação intra-examinador (CCI), erro sistemático e erro casual. A análise de variância a três critérios e pós-teste de Tukey foram utilizados e, valor de p>0.05 foi adotado para analisar as principais diferenças. Resultados: As mensurações mostraram elevado coeficiente de concordância intraexaminador (CCI>0.97). A esplintagem de próteses implantossuportadas agiu favoravelmente na distribuição de tensões e na transmissão de tensões para o implante adjacente (p<0.001), quando comparado a próteses unitárias. O carregamento oblíquo foi mais prejudicial e, pontecializou a formação de tensões em implantes adjacentes (p<0.001). O aumento do comprimento foi um fator significante na avaliação dos modelos B e C (p=0.004), o modelo B apresentou maior concentração de franjas quando comparado com D e E (p<0.001). Conclusão: As próteses implantossuportadas esplintadas comportaram-se melhor biomecanicamente quando comparadas as próteses unitárias. O aumento do comprimento teve relevância na redução de tensões. O carregamento oblíquo foi mais prejudicial para a distribuição de tensões quando comparado com o carregamento axial. / Abstract: Purpose: The purpose of this study was to evaluate the influence of different lengths and splinting of implants on stress distribution in implant-supported prostheses under axial and oblique loading by means of the method of photoelasticity. Materials and methods: 05 models in photoelastic resin was prepared with different proposed situations, there were 400 applications for load analysis. Tensions were considered quantitatively and qualitatively using a randomized, single blind method. The reproducibility of the study was assessed using the intra correlation coefficient, systematic error and random error. The analysis of variance to three criteria and post - Tukey tests were used, and p values > 0.05 was adopted to analyze the main differences. Results: The measurements showed a high intra-concordance coefficient (ICC> 0.97). The prosthetic implant splinting acted favorably in the distribution of stresses and strains in the transmission next to the implant (p<0.001) when compared to the unitary prosthesis. The oblique loading was more damaging and potentialized the formation of stresses in adjacent implants (p<0.001). The increase in length was a significant factor for the evaluation of the models B and C (p = 0.004), the model B had a higher concentration of fringes as compared with D and E (p<0.001). Conclusion: The prosthetic implant splinted behaved better biomechanically compared prosthetics unit. The increased length was important in reducing stress. The oblique loading was more detrimental to the stress distribution compared to axial loading. / Doutor
200

Reconstrução imediata de diferentes defeitos peri-implantares em implantes pós-exodônticos : análise histomorfométrica em cães /

Pereira, Flávia Priscila. January 2013 (has links)
Orientador: Eduardo Hochuli Vieira / Co-orientador: Daniele Botticelli / Banca: Idelmo Rangel Garcia Junior / Banca: Wilson Roberto Poi / Banca: Michel Reis Messora / Banca: Cassio Edvard Sverzut / Resumo: Objetivo: A proposta deste estudo foi avaliar a regeneração óssea de defeitos criados cirurgicamente e naturais circunferenciais (gap) de implantes pósexodônticos. Materiais e método: Para este estudo foram utilizados 8 cães da raça labrador, nos quais foram instalados implantes imediatos (pós-exodônticos) nos alvéolos dos dentes P2 (2o pré-molar) e M1 (1o molar) inferiores bilaterais. Nos implantes da região dos 2º pré-molares bilaterais foram criados cirurgicamente defeitos peri-implantares vestibulares que foram preenchidos de um lado por osso autógeno - OA e do outro por osso bovino inorgânico Bio-Oss ®- OB. Nos alvéolos correspondentes aos primeiros molares (M1) os implantes foram instalados e os gaps (defeitos naturais) existente entre a tábua óssea vestibular e o implante, foram preenchidos por Bone Ceramic ® - (grupo BC) ou somente coágulo (grupo COA). Todos os sítios cirúrgicos foram posteriormente recobertos por membrana de colágeno reabsorvível (Biogide ®) e mantidos com cicatrizador. Após 4 meses de pós-operatório, os animais foram eutanasiados e os blocos ósseos processados laboratorialmente para análise histomorfométrica. Resultados: Os resultados obtidos nos implantes instalados na região do P2 mostraram que os valores do IS-C foram ligeiramente maior (2.3±0.8mm) no grupo OA, comparado ao grupo OB (1.7± 0.7 mm), enquanto o IS-B dos grupos OA e OB foram respectivamente de 2.7±0.7mm e 2.2±1.0 mm no lado vestibular e de 1.6±0.8mm e 0.8±0.5mm no lado lingual. As médias dos valores de PM-C, PM-B e PM-IS no grupo OA e OB foram respectivamente de 4.3±0.9mm, 4.7±0.9mm, 2.0±1.6mm e 4.3±0.6mm... / Abstract: Objective: The purpose of these studies were to evaluate bone regeneration at natural or surgically-created buccal defects at implants placed immediately into extraction sockets (IPIES). Material and methods: Eight Labrador dogswere used and implants were placed immediately into the extraction sockets of P2 (second premolar ) and M1 (first molar), bilaterally. At P2, the buccal wall of the extraction sockets was removed bilaterally to create a standardized defect, 4 mm wide coronally, 2 mm wide apically, and 6 mm height. At P2 sites, Bio-Oss at the test (OB) or autogenous bone at the control (OA) sites were used to fill the defects. At M1 sites, Bone Ceramic ® at the test (BC) or the clot alone (COA) were used to fill the defects. All surgical sites were subsequently covered by a resorbable collagen membraneand a non-submerged healing was allowed . After 4 months the animals were euthanized, bone blocks harvested and processed for histomorphometric analysis . Results: at P2 sites, IS- C values were slightly higher (2.3±0.8mm) in the OA compared to the OB (1.7±0.7 mm). IS- B were 2.7 ± 0.7mm and 2.2 ± 1.0mm on the buccal side and 1.6 ± 0.8mm and 0.8 ± 0.5mm on the lingual side at OA and OB groups, respectively. The average values of PM- C , B - PM and PM -IS in OA and OB groups were 4.3 ± 0.9mm , 4.7 ± 0.9mm , 2.0 ± 1.6mm and 4.3 ± 0.6mm , 4.8 ± 0.6mm , 2.5 ± 0.8mm, respectively. A statistically significant difference was only observed in the thickness of the buccal bony crest at 2-5 mm apically to IS (the implant neck) when the biomaterial (S -OCbt )... / Doutor

Page generated in 0.0405 seconds