• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 552
  • 114
  • 20
  • 18
  • 18
  • 17
  • 17
  • 11
  • 10
  • 9
  • 8
  • 4
  • 3
  • 2
  • 2
  • Tagged with
  • 739
  • 739
  • 508
  • 475
  • 153
  • 135
  • 122
  • 109
  • 90
  • 76
  • 76
  • 74
  • 72
  • 70
  • 60
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
231

Estudo in vitro de um material para selamento da interface implante-intermediário do tipo minipilar cônico em implantes de hexágono externo, hexágono interno e cone morse / In vitro sealing of a material of implant-abutment interface of mini conical pillar: inimplant external hexagon, internal hexagon and Morse taper

Mônica Lôbo do Nascimento 08 May 2012 (has links)
A micro infiltração de fluidos bucais e bactérias na interface implante e o intermediário são discutidos na literatura através de várias pesquisas pontuando e determinando que o espaço existente entre os componentes e as conexões dos implantes, chamados de GAP, que parece ser a fonte da infiltração de microorganismos, quer a partir de meio externo para meio interno ou vice versa, resultando em reações inflamatórias nos tecidos periodontais. Portanto, este estudo teve como objetivo analisar um método para evitar e ou pelo menos diminuir micro infiltração na interface implante-intermediário utilizando um material de vedação chamado Loctite® 222 (Henkel Ltda). Este é um material monocomponente, anaeróbico, tixotrópico, de baixa resistência à desmontagem sendo utilizado industrialmente para ajustar os parafusos. Os implantes testados neste estudo foram de três diferentes sistemas de conexão protética: hexágono externo (n = 10), hexágono interno (n = 10) e cone morse (n = 10) e estes foram todos fabricados pela mesma empresa (SIN - Sistema de Implantes). Inicialmente, esses implantes foram utilizados como grupo controle, não recebendo a aplicação do selante na área de conexão. Mini intermediários cônicos foram sentados sobre os corpos dos implantes e o torque foi aplicado seguindo recomendação dos fabricantes. Cada implante foi imerso em um criotubo de 2ml contendo 1,5 ml de BHI estéril. Todos foram inoculados com 250l de Enterecoccus faecalis (ATCC - 29212) no interior do criotubo. Os implantes foram limpos, esterilizados e divididos em 3 grupos testes. Uma fina camada do selante foi aplicada com microbrush sobre a área de conexão antes de encaixar os pilares e logo foi aplicado o torque conforme as recomendações do fabricante. Períodos de avaliação, de 7, 14, 21, 35, 49 e 63 dias foram realizados para analisar a presença de micro infiltração do meio interno dos implantes, seguindo regulamentações específicas no fluxo laminar. Os resultados mostraram a eficácia do material selante quando se compara o grupo controle com os grupos testes. Uma eficácia de 100% foi encontrada para todos os sistemas de implantes estudados, o hexágono externo, hexágono interno e cone morse. / Microbial and fluidic leakage in the implant-abutment interface are shown in literature through a variety of studies, accusing the space that exists between the components of the implant, called \"GAP\", which seems to be the source of the microorganism infiltration, either from the external to the internal environment or the inverse, resulting in inflammatory reactions of the periodontal tissues. Therefore, this study aimed to analyze a method to avoid or at least reduce microleakage at the implant-abutment interface by using a sealing material named Loctite ® 222 (Henkel Ltda). This is a single component, anaerobic, thixotropic, lowstrength threadlocker material industrially used to adjust screws. The implants tested in this study were of three different implant-abutment systems: external hexagon (n=10), internal hexagon (n=10) and morse cone connection (n=10) and these were all manufactured by the same company (SIN - Implant System). Initially, these implants were used as the control group, not receiving the sealant application at the connection area. Mini conical abutments were seated over the implant bodies and torque-tightened to 20 Ncm. Each implant was immersed in a 2ml cryotube containing 1.5 ml of sterile BHI. All implants were inoculated with 250l of Enterecoccus faecalis (ATCC - 29212) inside the cryotube. The same implants were then cleaned, sterilized and divided into 3 test groups. A thin layer of the sealant was applied on the connection area before seating the abutments and proceeding as described before. Evaluation periods of 7, 14, 21, 35, 49 and 63 days were performed to analyze the presence of external contamination of the internal environment, following specific regulations in laminar flow. The results showed the effectiveness of the sealant material when comparing the control group to the test groups. An efficacy of 100% was found for all implant systems studied, the external hexagon, internal hexagon and Morse cone connection.
232

Avaliação do direcionamento e angulação das fibras de colágeno ao redor de implantes do tipo cone morse e hexágono externo sob luz polarizada em cães / Histological evaluation of collagen fibers orientation and angulation around external hexagon and cone morse implants under a polarized light

Daniel Sartorelli Marques de Castro 08 February 2012 (has links)
Foram avaliados o direcionamento e as características das fibras colágenas ao redor de dois diferentes tipos de implantes, cone Morse e hexágono externo. Este estudo foi aprovado pelo comitê de ética no ensino e pesquisa em animais da Faculdade de Odontologia de Bauru, recebendo o protocolo de número 03/2008. Foram instalados 42 implantes em sete cães, sendo 14 do tipo hexágono externo (Osseotite - 3i, USA ) e 28 do tipo Cone Morse ( Titamax EX CM Neodent, Brazil ), todos receberam componentes protéticos, seguindo o protocolo de carga imediata, após 4 meses, todos os animais foram sacrificados e as amostras coletadas e processadas pelo sistema Exakt. Para a avaliação do direcionamento das fibras colágenas foram avaliadas 18 amostras, que foram observadas em um microscópio óptico, sobre a influência de luz polarizada. No grupo hexágono externo foram encontradas fibras colágenas oriundas do epitélio alveolar correndo paralelamente a superfície do implante e seu componente protético, em algumas amostras se uniam a outros grupos de fibras e se direcionavam a região das roscas do implante. Foram encontradas fibras que poderiam ser classificadas como perpendiculares em apenas 3 amostras, localizadas abaixo da plataforma protética, não foram observados sinais de inserção das fibras nas regiões do cilindro de proteção ou componente rotético, apenas abaixo da plataforma do implante. Ao redor das amostras do grupo cone morse, foram encontrados grupos de fibras que corriam paralelamente a superfície do componente protético, em direção a plataforma do implante. Em 6 amostras deste grupo, foram observadas fibras que foram classificadas como obliquas ou perpendiculares, distribuídas lateralmente a região mais profunda do componente protético, apresentando sinais de inserção, não foram observadas fibras se inserindo diretamente ao implante. Quando observamos os valores correspondentes aos dois grupos avaliados, podemos observar a maior predominância de fibras classificadas como paralelas-obliquas no grupo I, com 16 amostras, duas outras amostras deste grupo poderiam ser classificadas como obliquas. No grupo III, a maior predominância das amostras se encontram classificadas como obliquas, com 11 amostras, outras 5 amostras deste grupo podem ser classificadas como obliquasperpendiculares, o grupo Cone Morse apresentou um valor de 70,20 graus para a face vestibular e 54,73 graus para a face lingual, o grupo Hexágono externo, apresentaram valores médios de 19,88 graus para a face vestibular e 21,92 graus para a face lingual. Baseado na metodologia empregada e nos resultados encontrados, podemos concluir que o tipo de interface protética parece influenciar o comportamento do tecido conjuntivo e que a maior estabilidade fornecida pelos implantes que utilizam interface cônica, parece permitir a inserção de fibras de colágeno diretamente ao componente protético, proporcionando uma melhor estabilidade tecidual e proteção aos implantes. / This study aims to evaluate the presence and orientation of the collagen fibers around two different implant types. 42 implants were installed in seven dogs, 14 external hexagon (Osseotite - 3i, USA) and 28 cone morse (CM Titamax EX - Neodent, Brazil), all received prosthetic components, following the immediate loading protocol. After 4 months of healing, the animals were sacrificed and samples were collected and processed for histological evaluation by means of Exakt processing system. To assess the direction of collagen fibers, 10 samples from each group were evaluated in an optical microscope, under the incidence of polarized light. In the external hexagon group were found collagen fibers derived from alveolar epithelium running parallel to the implant and his prosthetic component, in some samples these fibers joined with other groups and drove to the implant threads. Were found Fibers that could be classified as perpendicular in only three samples, located below the implant platform, no insertion signals were observed on cylinder of protection or prosthetic component, just below the implant platform. Around the morse taper group samples were found groups of fibers that ran parallel to the surface of the prosthetic component toward the implant platform. In six samples of this group, were observed fibers that were classified as oblique or perpendicular, laterally distributed to the deepest region of the prosthetic component, showing signs of insertion, were no observed fibers inserting directly to the implant surface. When we look at the values corresponding to both groups, we can observe the predominance of fibers classified as parallel-oblique on group I, with 16 samples, two other samples of this group could be classified as oblique. On group III, the highest prevalence of the samples are classified as oblique, with 11 samples, five other samples of this group can be classified as oblique-perpendicular, the morse taper group showed a mean value of 70.20 degrees to the buccal and 54,73 degrees to the lingual, external hexagon group presented mean values of 19.88 degrees to Buccal and 21.92 degrees to lingual. Based on the methodology used and results, we conclude that the type of prosthetic interface appears to influence the behavior of the tissue and that the stability provided by the implants using conical interface, seems to allow the insertion of collagen fibers directly to the prosthetic component, providing better tissue stability and protection to the implants.
233

Avaliação de massa e rugosidade superficial de pastilhas de Ti-6Al-4V com aplicação de nanopartículas de prata submetidos ao teste de escovação / Evaluation of mass and surface roughness of Ti-6Al-4V tablets with silver nanoparticles application submitted to brushing test

Vinícius Rizzo Marques 09 December 2015 (has links)
Este estudo teve por objetivo avaliar a variação da massa e rugosidade de pastilhas de Ti-6Al-4V com e sem aplicação superficial de nanopartículas de prata coloidal (BSafe®) de dimensões 1,5 cm; 0,5 cm e 0,2 cm, submetidas à teste de escovação e imersão pelo período experimental de 10 anos. No teste de escovação, quinze espécimes de Ti-6Al-4V (TE), quinze com B-Safe® (BE) e quinze de PMMA (PE) como controle foram subdivididos em três condições de escovação: dentifrício comum (DC), dentifrício experimental (DE) e controle com água destilada (H2O) por 200 mil ciclos em máquina de escovação. Os resultados foram submetidos ao teste ANOVA a 2 critérios (condição de escovação e ciclos) e teste de Tukey (α=0,05) para comparações múltiplas. Foi observada variação de massa apenas quando a condição de escovação foi DC nos espécimes do grupo PE e TE. Houve diferença estatisticamente significante nos valores da variação de rugosidade no grupo TE e PE quando a condição de escovação foi DC; no grupo BE, houve diferença quando a condição foi DC e DE, porém em DE houve redução dos valores médios. No teste de imersão, objetivando analisar a ação dos dentifrícios sem o atrito das cerdas, seis espécimes de Ti-6Al-4V (TI) e seis com B-Safe® (BI) foram subdivididos em três condições de imersão: DC, DE e H2O pelo período de 244 horas. Os resultados foram submetidos ao teste t de student pareado. Não foi observada diferença estatística entre as variações de massa e rugosidade de nenhum dos corpos de prova após o teste. Complementar aos ensaios, foi realizado um protocolo de desinfecção com terapia fotodinâmica com azul de metileno pelo período de 4 semanas nos espécimes escovados. Após todos os testes, foi realizada espectrometria de energia dispersiva de raios-X (EDS) para caracterização dos elementos químicos presentes nos espécimes, onde não se observou variações. Os resultados sugerem que o DE é mais indicado para utilização com implantes, enquanto DC apresenta um poder abrasivo capaz de danificar a superfície do Ti-6Al- 4V. Não foi observado nenhum indício de corrosão em nenhum grupo testado. / This study aimed to evaluate the variation of mass and roughness of Ti-6Al-4V tablets with and without superficial application of colloidal silver nanoparticles (BSafe®) with dimensions of 1,5 cm; 0,5 cm and 0,2 cm, submitted to brushing and immersion test for an experimental period of 10 years. For the brushing test, fifteen specimens of Ti-6Al-4V (TE), fifteen with B-Safe® (BE) and fifteen of PMMA (PE) as control were subdivided into three brushing conditions: normal toothpaste (DC), experimental toothpaste (DE) and control with distilled water (H2O) by 200 thousand cycles in brushing machine. The results were submitted to the ANOVA test on 2 criteria (brushing condition and cycles) and the Tukey test ((α= 0,05) for multiple comparisons. Mass variation was observed only when the brushing condition was DC, in PE and TE groups. Statistically significant difference was observed in the values of roughness variation on TE and PE group when the brushing condition was DC; in the BE group, there was difference when the condition was DC and DE, however in DE there was reduction of the average values. In the immersion test, aiming to analyze the action of toothpastes without the friction of the bristles, six specimens of Ti-6Al-4V (TI) and six with B-Safe® (BI) were subdivided into three immersion conditions: DC, DE and H2O for a period of 244 hours. The results were submitted to paired student t-test. No statistical difference was observed between mass and roughness variation for any of the specimens after the test. Additional to the tests, a disinfection protocol with photodynamic therapy with methylene blue was performed for a 4-week period on the brushed specimens. After all tests, Energydispersive X-ray Spectroscopy (EDS) was performed for characterization of the chemical elements present in the specimens, in which no variations were observed. The results suggest that DE is most suitable for use with implants, while DC has a higher abrasive power capable of damaging the Ti-6Al-4V surface. There was no evidence of corrosion in any tested group.
234

Análise histomorfométrica de implantes hidrofóbicos e hidrofílicos: estudo experimental em coelhos / Comparative histomorphometric analysis of hydrophobic and hydrophilic implants: an experimental study in rabbits

Verena Souza da Cunha 03 June 2015 (has links)
O íntimo contato entre osso e implante é considerado um pré-requisito fundamental para o sucesso dos implantes dentários, condição esta conhecida como osseointegração. Devido a isto, um grande número de pesquisas com tratamentos de superfícies de implantes vem sendo desenvolvido por várias empresas nos últimos anos, visando acelerar esse fenômeno. O objetivo deste trabalho é avaliar histomorfometricamente o percentual de contato osso-implante (BIC) e área de osso novo (BA) entre implantes de tratamento de superfície Neoporos (GC - hidrofóbico) e implantes com energia de superfície molhada Acqua (GE - hidrofílicos). Foram utilizados 15 coelhos da raça new zealand, que receberam 30 implantes divididos em cada lado de suas tíbias direita e esquerda, ambos de titânio comercialmente puro grau IV com 3.5x8mm de dimensão, sendo ao final de 15 dias, a região dos implantes coletada e processada histologicamente para obtenção de cortes teciduais não desmineralizados, embora dois implantes do grupo Esm tenham sido excluídos da pesquisa devido à instalação ter ocorrido dentro do canal medular e terem obtido tecido necrosado, não cumprindo as características de osseointegração. Para análise dos dados estatísticos, utilizou-se o teste t de Students para amostras independents e teste Mann-Whitney Rank Sum com nível de significância de p<0.05. Os resultados mostraram que não houve diferença estatisticamente significante entre os grupos para a análise de BIC. O grupo GC apresentou a média de 42.9% de BIC, ligeiramente menor que o grupo GE, que apresentou 49.3% de média. Já para o teste BA houve diferenças de 15%, em que o grupo GC apresentou 58.6% e o grupo GE, 74.4%. A conclusão é que há, ainda, necessidade de maiores estudos a cerca do referido tema. / The near contact between bone and implant is considered an essential pre-requisite for the success of dental implants, a condition known as osseointegration. Due to it, a great amount of researches on implants surface treatments has been developed by several companies in recent years to accelerate the phenomenon of osseointegration. The aim of the present study is to evaluate histomorphometrically the percentage of bone-implants contact (BIC) and the area of new bone (BA) between implants with surfaces treatment Neoporos (GC - hydrophobic) and implants with wets surface energy Acqua (GE - hydrophilic). It was used fifteen (n=15) New Zealand rabbits, which received thirty implants installed dividing them between its right and left tibias. Implants were commercially pure titanium grade IV with 3.5x8mm dimension. After fifteen days, the implants area were collected and processed histologically in order to obtain not demineralized tissue sections. For statistical data analysis, it was used the t test for independents samples and Mann-Whitney Rank Sum test. The significance level was p<0.05. Results showed no statistical significant difference between groups for BIC analysis. The control group showed a mean of 42.9% of BIC, slightly lower than the GE group, which showed a mean of 49.3%. For BA test, there was a significant difference of more than 15% in the control group (58.6% for the GC group and 74.4% for GE group). It was concluded that futher studies is needed on this topic of osseointegration and hydrophobic /hydrophilic implants.
235

Avaliação in vitro da capacidade de vedamento bacteriano da interface implante e componente protético em sistema cone Morse em função de alterações estruturais e uso de selantes industriais / In vitro evaluation of the sealing ability of bacterial interface implant and prosthetic component in Morse taper system due to structural changes and the use of industrial sealants

Antonio da Silva Ramos Neto 13 November 2013 (has links)
O objetivo deste estudo foi comparar, in vitro, os sistemas de implante cone Morse, frente ao vedamento contra a penetração bacteriana entre o implante e o componente protético, em função de alterações estruturais e uso de selantes industriais. Foram utilizados 126 implantes Titamax CM EX distribuídos em três tipos de componentes protéticos: Munhão Universal CM, Munhão Universal CM com Parafuso Passante e Munhão Universal CM Exact, todos da empresa Neodent (Curitiba, Paraná, Brasil). Estes implantes foram divididos em 3 grupos de 42 implantes componentes protéticos, sendo os grupos devidamente denominados: Grupo 1 (G1) - Controle, Grupo 2 (G2) - Jateamento e Grupo 3 (G3) - Adesivo. Estes implantes, devidamente distribuídos entre os componentes protéticos e seus grupos, foram avaliados quanto à contaminação bacteriana em um período de 28 dias após o término da experimentação inicial em que foi realizado o efeito de ciclagem sobre as amostras (sem e com carga). Os implantes foram perfurados em sua porção apical com uma fresa de 1mm de diâmetro, até o encontro de sua câmara interna. Foram instalados os componentes protéticos de titânio em cada grupo com torque recomendado pelo fabricante (32 e 15 N.cm). Antes os componentes dos grupos G2 e G3 passaram por alterações estruturais (jateamento e adesivo Dermabond® respectivamente). As peças foram anexadas a tampas de tubo de ensaio, com a porção do componente voltada para o interior do tubo. Os tubos de ensaio foram preenchidos com meio de cultura líquido LB, utilizando-se seringa estéril. Todos os conjuntos receberam esterilização por radiação Gama (Embrarad, Campinas, Brasil). Após a confirmação da efetividade da esterilização por meio de amostras controle, os orifícios apicais foram cuidadosamente desobstruídos e inoculados com cultura de E. coli. O controle de turvamento das amostras foi realizado diariamente, os resultados apontaram que três das amostras do G1, sete do G2 e duas do G3, que não foram submetidas a ciclagem, sofreram contaminação num período de até 28 dias, e que três amostras do G1, dez do G2 e nenhuma do G3, quando submetidas ao efeito da ciclagem, foram contaminaram. Todos os grupos apresentaram infiltração bacteriana, independentemente do componente protético e da ciclagem. Ficou evidenciado que o grupo jateamento apresentou os piores resultados e que o adesivo apenas reduziu, mas não impediu a infiltração bacteriana para o interior dos implantes cone Morse. / The aim of this study was to compare, in vitro, Morse taper implant systems sealing against bacterial penetration between implant and prosthetic component after modifying the abutment structure or using industrial strength sealants. 126 Titamax CM EX implants and three different types of prosthetic components were used: Universal Post CM, CM Universal Post with passing screw and Universal Post CM Exact (Neodent implants, Curitiba, Parana, Brazil). These samples were divided into three groups: Group 1 Control group (G1); Group 2 Sandblasting (G2); and Group 3 Adhesive (G3). The implant / prosthetic component bacterial leakage from each group was evaluated after 28 days with or without cyclic loading. A hole at the apical portion of the implant was done with a 1 mm bur to access the implant internal threads. The abutments were inserted and torqued according to the manufacturer recommendation (15 or 32 N.cm). G2 abutments were sandblasted before insertion. G3 abutments were sealed with Dermabond® adhesive. The samples were sterilized by Gamma irradiation (Embrarad, Campinas, Brazil) and attached to the test tube lid and placed in the test tube filled with bacterial growth media (LB). Control samples from each group were used to assess bacterial contamination before starting the experiment. The access holes at the apical part of the implants were accessed and an E. coli culture was inoculated inside the implant internal threads and then sealed again. Changes in the media color (turbidity), indicative of bacterial leakage from inside the implant to the media were evaluated daily. Three samples from G1, seven from G2 and two from G3 without cyclic loading showed bacterial leakage after 28 days. Three samples from G1, ten from G2 and none of the samples from G3 showed bacterial leakage in the cyclic loading condition. All groups demonstrated bacterial leakage disregard of the type of abutment and loading conditions. It was demonstrated that G2 (sandblasted surface) had the worst results. Use of industrial sealant reduced but did not completely prevented bacterial leakage in Morse taper implants.
236

Atividade muscular e alterações mandibulares em usuários de prótese fixa implanto suportada / Muscular activity and mandibular bone changes on patients provided with implant-supported fixed prosthesis

Mônica Moraes Waldemarin Lopes 30 October 2006 (has links)
Objetivo: As alterações na altura óssea da região posterior ao último implante mandibular em indivíduos reabilitados com próteses fixas implanto suportadas foram correlacionadas com força de mordida (FM) e com a atividade massetérica em função. Métodos: radiografias panorâmicas antes e 1 ano depois da reabilitação de 10 pacientes do Hospital de Reabilitação de Anomalias Craniofaciais (HRAC – USP), foram avaliadas quanto à presença de alteração dimensional óssea. A FM foi registrada por meio de um gnatodinamômetro. Eletromiografia dos masseteres foi realizada e traduzida pelos parâmetros: contração voluntária isométrica máxima (CVIM) durante 5 segundos, mastigação habitual de cenoura (MHC) e mastigação unilateral direita (MUD) e esquerda (MUE) com látex. Resultados: houve um aumento médio da altura óssea mandibular de 0,23 ±0,4 mm; a FM média foi 42 ±5,9 Kgf e a CVIM foi de 66,7 ±23,7 µV. Os valores médios para MHC foram: ato 0,52 ±0,02 s; ciclo 1,3± 0,67s e amplitude (potência) 85,98 ±19,53µV; para MUD com látex foram: ato 0,59s, ciclo 0,89 ±0,22s amplitude 86,93 ±26,67µV, e os da MUE com látex foram: ato 0,56s, ciclo 1,35 ±0,69s e amplitude 90,89 ±32,96µV. Somente houve significância estatística do lado direito entre alteração dimensional óssea e o ato da MHC (p= 0,036); do lado esquerdo com o ato da MUD com látex - lado de balanceio (p= 0,026). Conclusão: o aumento médio da altura óssea na região posterior da mandíbula não se correlacionou significantemente com a maioria dos parâmetros analisados, sugerindo que a duração, mais que a potência da atividade muscular pode ter influência nas alturas observadas. / Objectives: Changes on mandibular high posterior to the most distally positioned implant on patients provided with implant-supported fixed prosthesis were related to bite force (FM) and functional maseteric activity. Methods: orthopantograms taken before and one year after rehabilitation of 10 patients from the Hospital for Rehabilitation of Craniofacial Anomalies (HRAC-USP) were evaluated. The FM was registered by a gnatodynamometer. Electromyography of masseteric muscle was performed and interpreted as follows: maximum voluntary isometric clench (CVIM) during 5 seconds, habitual chewing of carrot (MHC) and unilateral right (MUD) and left (MUE) chewing with latex. Results: there was a mean increases in mandibular bone high of 0,23 ± 0,4mm; the mean FM was 42 ±5,9Kgf and CVIM was 66,7 ± 23,7 µV. The mean values for MHC were: act 0,52± 0,02s; cycle 1,3± 0,67s and the voltage amplitudes 85,98± 19,53µV; for MUD with latex the values were: act 0,59s, cycle 1,35 ± 0,69s and voltage amplitudes 90,89± 32,96µV. There was only statistically significant difference between dimensional bone changes and act of MHI (p= 0,036) for the right side; and for the left side between MUD act with latex and balance side (p=0,026). Conclusions: the mean increase on bone high observed at the posterior region of the mandible was not significantly related to the majority of the analyzed parameters. This suggests that the lasting more than the amplitude of the muscular activity may have influenced the measurements observed.
237

Avaliação da resistência à flexão de mini-implantes desenvolvidos para ancoragem esquelética do aparelho de Herbst - Estudo em Minipig br1 / Flexure resistance evaluation of mini implants prototypes developed for Herbst appliance anchorage Study in Minipig br1

Klaus Barretto dos Santos Lopes Batista 23 April 2010 (has links)
Um efeito colateral indesejável do uso do aparelho de Herbst é a vestibularização excessiva dos incisivos inferiores que pode estar relacionada à retração gengival, à perda óssea marginal e à reabsorção radicular. A ancoragem esquelética do aparelho de Herbst poderia evitar estes problemas. O objetivo do presente estudo foi o de avaliar, em Minipigs br1, a resistência à flexão de protótipos de mini-implantes desenvolvidos para ancoragem do aparelho de Herbst, comparar a resistência dos protótipos entre as duas regiões escolhidas para inserção e avaliar se os protótipos de mini-implantes seriam capazes de suportar forças ortopédicas. Após o cálculo do tamanho da amostra, 13 protótipos de mini-implantes foram colocados nas regiões posterior da maxila e anterior da mandíbula de três Minipigs br1, após terem sido mortos. Corpos de prova contendo os protótipos de mini-implantes inseridos em osso foram submetidos a uma força de flexão por engastamento simples utilizandose uma máquina universal de ensaios mecânicos Instron, calculando-se a média e o desvio padrão para cada região. Com o objetivo de comparar a resistência dos protótipos entre as regiões de inserção foi utilizado o Teste t de Student para duas amostras não pareadas. O teste de hipótese foi realizado para cada região para avaliar se os protótipos de mini-implantes seriam capazes de suportar forças ortopédicas. Para fins de comparação foram consideradas forças ortopédicas acima de 1,0 kgf. O nível de significância adotado foi P < 0,05. Os protótipos de miniimplantes apresentaram resistência à força de flexão de 13,86 kgf (DP = 2,3) para a região posterior da maxila e 20,55 kgf (DP = 5,2) para a região anterior da mandíbula. Houve diferença estatisticamente significativa entre as duas regiões com relação à força de resistência dos mini-implantes (P = 0,015), sendo que a resistência maior foi na região anterior da mandíbula. A hipótese de que os protótipos de mini-implantes seriam capazes de suportar forças ortopédicas foi confirmada para as regiões posterior da maxila e anterior da mandíbula. Os autores concluíram que, em Minipigs br1, os protótipos de mini-implantes desenvolvidos para a ancoragem do aparelho de Herbst foram capazes de resistir a forças entre 13,86 e 20,55 kgf, sendo estatisticamente mais resistentes na região anterior da mandíbula e capazes de suportar forças ortopédicas. / An undesirable tooth movement resulting from use of the Herbst appliance is the excessive proclination of the anterior mandibular teeth, which is commonly associated with gingival recession, marginal bone loss, and root resorption. Skeletal anchorage of the Herbst appliance could prevent these problems. The present study was designed to evaluate, in Minipigs br1, the flexure resistance of prototype miniimplants developed for Herbst appliance anchorage, to compare the prototype resistance between the regions in which the mini-implants were placed, and to test the hypothesis that these mini-implant prototypes can withstand orthopedic forces. After calculation of sample size, 13 mini-implant prototypes (2 mm in diameter x 10 mm long) were inserted in the posterior region of the maxilla and the anterior region of the mandible, in three recently killed minipigs. The specimens were submitted to a single cantilever flexure test using an Instron testing machine. Mean and standard deviation were calculated for each region. To compare the resistance of the prototypes between the sites of mini-implant insertion, a 2-Sample Students t test was calculated. The test was carried out individually for each region, to evaluate if the prototype mini-implants developed for Herbst appliance anchorage could withstand orthopedic forces. Orthopedic forces above 1.0 kgf were considered. The level of significance was set at P < 0.05. The prototype mini-implant showed a flexure strength of 13.86 kgf (SD = 2.3) for the posterior region of the maxilla, and 20.55 kgf (SD = 5.2) for the anterior region of the mandible. A significant statistically difference was found in the resistance of the prototypes between the two regions (P = 0.015). The hypothesis that the prototype mini-implants can withstand orthopedic forces was confirmed. The authors concluded that, in Minipigs br1, the prototype mini-implants developed for Herbst appliance anchorage could resist forces from 13.86 to 20.55 kgf, were statistically more resistant in the anterior region of the mandible, and were capable of withstanding orthopedic forces.
238

Dispositivo customizado produzido por manufatura aditiva para reabilitação oral em pacientes com regiões de atrofia óssea em áreas desdentadas extensas : Custom device produced by additive manufacturing for oral rehabilitation in patients with bone atrophy in regions of large edentulous areas / Custom device produced by additive manufacturing for oral rehabilitation in patients with bone atrophy in regions of large edentulous areas

Cardoso, Luiz de Camargo, 1958- 24 August 2018 (has links)
Orientador: Cecília Amélia de Carvalho Zavaglia / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecânica / Made available in DSpace on 2018-08-24T20:04:45Z (GMT). No. of bitstreams: 1 Cardoso_LuizdeCamargo_M.pdf: 3937721 bytes, checksum: 35ed94c8bb9f043e9e463bd489f44ae5 (MD5) Previous issue date: 2014 / Resumo: A necessidade de reabilitação oral gera o desenvolvimento de inúmeras pesquisas com o intuito de inovações nesta área. O aumento da expectativa de vida, a busca pelo conforto e saúde são fatores primordiais para os aprimoramentos dos novos dispositivos de reabilitação oral. A atual pesquisa trata do desenvolvimento de um dispositivo de titânio intra-oral visando a reabilitação oral em pacientes com regiões ósseas atróficas. Para tanto foram realizados: a obtenção e tratamento da tomografia de um caso adequado; a criação do modelo virtual da mandíbula e do dispositivo; a confecção destes pelo processo de manufatura aditiva; ensaios de flexão e estudos in vitro do material Os valores de resistência à flexão do material foram superiores ao da região mandibular de um humano saudável. A análise do resultado do ensaio de citotoxicidade do titânio Ti-6Al-4V evidencia as características deste de ser um biomaterial. A análise dos resultados dos ensaios, mecânicos e do estudo in vitro, viabiliza a aplicação da liga de titânio Ti-6Al-4V no desenvolvimento deste dispositivo para reabilitação oral. O dispositivo se adapta perfeitamente ao protótipo da mandíbula, permitindo que posteriormente se torne justaposto ao osso e seja fixada a parte protética. Desse modo, o dispositivo desenvolvido possui características adequadas para se tornar uma opção factível para pacientes com regiões orais atróficas posteriores / Abstract: Research and new techniques are a real needed for a better treatment in oral rehabilitation. The increase of life expectancy leads to a search for comfort and health, Are fundamental for the development of devices that may provide an increase in life quality. The scope of this research is the development of a titanium device for intra-oral use that may allow oral rehabilitation in patients with atrophic and extended areas of bone lost. This research aims the device development which will give oral rehabilitation solution to cases where absences of vertical bone quantity does not allow the placement of traditional implants. In this study, were made the gathering and processing of the tomography of an appropriate case, the manufacture of the device by the virtual model and by additive manufacturing, the mechanical flexural test and cytotoxicity study where performed. The results presented show viability for the application that was studied. The flexural strength of the biomaterial was higher than the mandible region of a healthy human and the choice of the materials (titanium Ti - 6Al -4V) did not show any characteristic of cytotoxicity. The developed device is suitable as a prototype of the mandible, allowing subsequent juxtaposition to the bone and be is fixed in the prosthetic part. Thus, the developed device has suitable characteristics to become a feasible option for patients with atrophic oral posterior regions / Mestrado / Materiais e Processos de Fabricação / Mestre em Engenharia Mecânica
239

Análise fotoelástica da distribuição de tensões geradas por carregamento em coroas unitárias suportadas por implantes curto e longo / Photoelastic analysis with different width and height crown loaded over short and long single dental implant

Carvalho, Breno Carnevalli Franco de, 1963- 12 September 2013 (has links)
Orientador: Rafael Leonardo Xediek Consani / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-24T03:25:43Z (GMT). No. of bitstreams: 1 Carvalho_BrenoCarnevalliFrancode_D.pdf: 2254429 bytes, checksum: 0864903c9e5a5e409b843fd792284ecc (MD5) Previous issue date: 2013 / Resumo: Implantes curtos são utilizados em situações clínicas quando a altura e/ou a espessura óssea são insuficientes. A proposta neste estudo foi verificar por meio da análise de tensão fotoelástica a influência exercida pela altura e largura da coroa protética na força transmitida aos implantes curto (7 mm) e longo (13 mm) quando o carregamento foi efetuado no centro ou na extremidade das coroas. As dimensões da altura e da largura da coroa simulada foram estabelecidas com base nas dimensões de dentes pré-molar e molar inferiores humanos e a espessura estabelecida em 6 mm. O corpo-de-prova de resina fotoelástica foi feito com o sistema bi componente à base de resina epóxi modificada e endurecedor. Os carregamentos foram de 0,4 kgf no centro e de 0,3 kgf numa das extremidade da coroa. A análise fotoelástica avaliando as ordens de franjas ao redor dos implantes foi feita com polariscópio de transmissão. Cada fotografia foi analisada três vezes no programa Fringes para ordens de franja de 0 a 4, considerando as médias da ordem das franjas e da tensão cisalhante para cada ponto estabelecido no modelo. Os dados foram submetidos à ANOVA dois fatores e diferenças estatísticas comparadas pelo teste t de Student em nível de significância de 5%. Os resultados mostraram que não houve diferença entre os níveis de tensões gerados pela altura e largura das coroas protéticas sobre os implantes curto e longo, quando os carregamentos foram feitos tanto no centro como na extremidade das coroas. Concluiu-se que as tensões geradas sobre os implantes curto e longo foram similares qualquer que fosse o tamanho e o local dos carregamentos aplicados sobre as coroas; houve diferença na magnitude da tensão exercida sobre os implantes curto e longo, sendo maior para o implante curto / Abstract: Short implants are used in clinical situations when the mass of bone is deficient in height and/or thickness. The purpose of this study was to verify the height and width crown influence in the stress transmission in short (7mm) and long (13mm) implants when loaded at center and edge of the crown. The simulated crown dimensions were established using a natural premolar and molar crown dimensions and the thickness was 6 mm. The photoelastic models were made using a dual system based on modified epoxi resin and catalyser. The crowns were loaded with 0,4 kgf at the center and 0,3 kgf at the edge. The photoelastic analysis for fringe order around the implants was made using a transmission polariscope. The maximum shear stress and the fringe values from 0 to 4 were determined in each photography measured three times using Fringes software. Two-way ANOVA and t Student test at 5% significance were perfomed. The results showed no difference in the stress levels produced by different height and width crown over the short and long implants when loaded both center and edge of the crowns. In conclusion, the results showed similar stress on the short and long implants regardless the size and the loaded crown area; however, there was statistical difference in the stress level on the implants being higher for the short implant / Doutorado / Protese Dental / Doutor em Clínica Odontológica
240

Rehabilitation of fully edentulous maxilla = retrospective survival analysis of dental implants in native x autogenous bone and proposed technique for bone reconstruction with rhBMP-2 = Reabilitações de maxilas totalmente edêntulas: análise retrospectiva de sobrevida de implantes dentários em osso nativo x enxerto autógeno e proposta de técnica para reconstrução óssea com rhBMP-2 / Reabilitações de maxilas totalmente edêntulas : análise retrospectiva de sobrevida de implantes dentários em osso nativo x enxerto autógeno e proposta de técnica para reconstrução óssea com rhBMP-2

Moraes, Paulo Hemerson de, 1982- 24 August 2018 (has links)
Orientador: José Ricardo de Albergaria Barbosa / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-24T03:15:23Z (GMT). No. of bitstreams: 1 Moraes_PauloHemersonde_D.pdf: 8285563 bytes, checksum: e294a6dc0647058066633e61386f29b1 (MD5) Previous issue date: 2013 / Resumo: Em maxilas severamente absorvidas, como tratamento de reabilitação, podem ser utilizados os implantes dentais osseointegráveis convencionais. Todavia, nestas situações, estão presentes obstáculos para a instalação dos implantes como: quantidade insuficiente e qualidade inadequada do osso encontrado na maxila. Nestas situações, são necessárias cirurgias reconstrutivas para restabelecer as dimensões do rebordo avelolar em espessura e altura possibilitando assim a instalação adequada destes implantes. Geralmente, essas reconstruções utilizam osso autógeno retirado de algum sitio doador do paciente, como a calota craniana, costela e crista do ilíaco. Alternativamente, com os avanços da engenharia tecidual, a rhBMP-2 (recombinant human bone morphogenethic protein-2) surgiu eliminando a necessidade de qualquer remoção de sítio doador como também qualquer outro biomaterial nas reconstruções ósseas dos maxilares deixando o procedimento com menor morbidade e maior aceitabilidade dos pacientes. Desta forma, a presente pesquisa apresenta 2 estudos descritos nos capítulos a seguir. CAPÍTULO 1: O objetivo deste estudo foi avaliar a sobrevida de implantes instalados em osso nativo de maxilas como também nas reconstruídas com osso autógeno. Foi obtido um acompanhamento de 8-10 anos com pacientes de ambos os grupos reabilitados com próteses fixas sobre implantes dentais. O sucesso dos implantes em maxilas reconstruídas com ósso autogeno não apresentaram diferenças estatísticas à implantes inseridos em maxilas com osso nativo. CAPÍTULO 2: O objetivo deste estudo foi apresentar uma nova técnica de reconstrução óssea de maxila utilizando rhBMP-2 objetivando previsibilidade e melhores resultados no aumento do volume ósseo necessário. A técnica sugerida ofereceu bons resultados no volume ósseo a ser obtido nas reconstruções ósseas de maxila com rhBMP-2. / Abstract: In maxillary severely absorbed as rehabilitation treatment, can be used conventional dental implants. However, these situations are present obstacles to the installation of the implants as insufficient and inadequate quality of bone found in the jaw , as well as the expansion of the maxillary sinus pneumatization . In these situations, it is necessary reconstructive surgery to restore the dimensions of thickness and height on rim thus allowing proper installation of these implants. Generally, these reconstructions using autogenous bone taken from a donor site from the patient , such as calota craneal , rib and the iliac crest . Alternatively, with advances in tissue engineering, rhBMP-2 (recombinant human bone morphogenethic protein-2) appeared eliminating the need to remove any donor site as well as any other biomaterial in the maxila bone reconstruction procedure with leaving the lower morbidity and higher patient acceptability. Given the above, this research presents two studies described in the following chapters. CHAPTER 1: The objective of this study was to evaluate the survival of implants placed in native bone in the maxilla as well as in maxilla reconstructed with autogenous bone. We obtained a follow-up of 8-10 years with both groups of patients rehabilitated with fixed prostheses on dental implants. The survival of implants in maxilla was reconstructed with autogenous bone implants inserted into the lower maxilla with native bone. CHAPTER II: The objective of this study was to present a new technique for reconstruction of maxilla bone using rhBMP-2 seeking precision in increased bone volume needed. The suggested technique offered precision in bone volume to be obtained in the maxilla bone reconstruction with rhBMP-2. / Doutorado / Cirurgia e Traumatologia Buco-Maxilo-Faciais / Doutor em Clínica Odontológica

Page generated in 0.053 seconds