• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 552
  • 114
  • 20
  • 18
  • 18
  • 17
  • 17
  • 11
  • 10
  • 9
  • 8
  • 4
  • 3
  • 2
  • 2
  • Tagged with
  • 739
  • 739
  • 508
  • 475
  • 153
  • 135
  • 122
  • 109
  • 90
  • 76
  • 76
  • 74
  • 72
  • 70
  • 60
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
271

Avaliação da precisão da tomografia computadorizada por feixe cônico (cone beam) como método de medição do volume ósseo vestibular em implantes dentários / Evaluation of the accuracy of computed tomography cone-beam (cone beam) as a method of measuring buccal bone volume in dental implants

Shiratori, Lucy Naomi 07 December 2009 (has links)
A monitoração radiográfica das mudanças no nível ósseo fornece sinais valiosos para assegurarmos a longevidade e estética dos implantes. As radiografias periapicais e panorâmicas são importantes instrumentos que permitem esta avaliação, mas tem limitações, pois fornecem imagem bidimensional. As imagens tomográficas fornecem detalhes para estimar dimensões verticais e horizontais, possibilitam a melhor visualização de defeitos ósseos e estruturas anatômicas para o planejamento cirúrgico, além de permitir a monitoração radiográfica pós-cirúrgica ao redor dos implantes. O propósito deste trabalho foi avaliar a precisão da tomografia computadorizada por feixe cônico (TCCB) na medição do volume ósseo vestibular ao redor de implantes. Foram utilizados 8 crânios secos que receberam de 3 a 6 implantes na região da maxila anterior dependendo da disponibilidade óssea, em seguida foi realizada uma TCCB. Por meio dos cortes das imagens, as medições da parede óssea em 3 pontos do implante foram obtidas, analisadas e comparadas às realizadas no modelo do crânio em gesso, que continha implantes da mesma altura e diâmetro, nos mesmos pontos determinados, ou seja, no ápice do implante (A), a 5 mm do ápice (B) e do primeiro contato osso/implante até a plataforma do implante (C). O resultado do estudo mostrou que para os 3 pontos (A, B, C) não houve diferença estatisticamente significante das medidas realizadas no modelo real com a tomografia, ou seja, a TCCB pode ser um instrumento útil para se avaliar longitudinalmente o volume ósseo vestibular, porém, mais estudos clínicos se fazem necessários para ser utilizado na clínica diária. / Monitoring radiographic changes in bone level provides valuable signals to insure the longevity and aesthetics of implants. The panoramic and intra-oral radiographs are important devices for this assessment, but have limitations, they provide twodimensional images. The computed tomographics images provide details to estimate vertical and horizontal dimensions, allow for better visualization of bone defects and anatomical structures important in surgical planning, avoiding anatomical regions that could result in surgical injuries, and allows radiographic monitoring after surgery around implants , a factor of great importance for aesthetics and longevity of implants. The purpose of this study was to evaluate the accuracy of cone beam computed tomography (TCCB) in measuring the buccal bone volume around these implants. 8 skulls were used to install 3 to 6 implants in the anterior maxilla (canine to canine) depending on the availability of bone. These implants were installed in the skull, and then held a TCCB. Through the courts of the images, measurements of the bone wall at 3 points of the implant were obtained, analyzed and compared to those obtained in the model of the skull in plaster. Implants with the same height and diameter were used in the model and the same points determined, ie, the apex of the implant (A), 5 mm from the apex (B) and the first contact implant-bone to the plataform of the implant, were measured. (C).The results showed that for the 3 points (A, B, C) of the implants, no statistically significant difference in measurements obtained from the plaster model and computed tomographics images. Considering the results, TCCB can be a useful tool for assessing buccal bone volume along the implant, however, further studies are needed to be used in clinical practice.
272

Effect of CAD/CAM abutment height and cement type on the retention of zirconia crowns / Efeito da altura do pilar CAD / CAM e tipo de cimento na retenção de coroas de zircônia

Silva, Camila Perfeito Evangelista da 07 May 2018 (has links)
Aim: To evaluate the effect of different Ti-base abutment heights and cement type on the pullout retention of zirconia-based restorations. Methods: Identical crowns were designed in a CAD software to fit two different Tibase abutment heights, as follows (n=10/group): (i) 4-mm-height Ti-base abutment (Tall), and (ii) 2.5-mm-height Ti-base abutment (Short). Four cement types were selected: (i) Temporary cement (Provisional); (ii) Glass-ionomer cement (Meron); (iii) self-adhesive resin cement (U200), and (iv) conventional resin cement (Ultimate) with universal adhesive for treatment of titanium and zirconia substrates. Pull-out testing was performed in a universal testing machine. Data were statistically evaluated through two-way analysis of variance following post-hoc comparisons by Tukey test. Results: Tall Ti-base abutments demonstrated similar retention to short abutments when data is collapsed over cement (p>0.74). Data evaluation as a function of cement type demonstrated the superiority of resin-based cements relative to provisional and glass-ionomer groups (p<0.01). Retentiveness data as a function of both factors demonstrated similar force to dislodgment between tall and short abutments for all within cement comparisons (p>0.42), except for U200 (p=0.032). Also, tall abutments cemented with Ultimate evidenced higher pull out values than U200 (p=0.043), and both were significantly more retentive than tall provisional and meron (p<0.001). No significant difference was observed between U200 and Ultimate cements for short abutments (p=0.758), and both presented statistically higher pullout values than provisional and glass-ionomer (p=0.001). Conclusions: While Ti-base abutment height have not influenced zirconia superstructure retentiveness, resin-based cements significantly evidenced higher retention than glass ionomer and temporary cements. / Objetivo: Avaliar o efeito de diferentes alturas de interface de Titânio (Ti) e diferentes tipos de cimento na retenção de coroas de zircônia. Métodos: Coroas idênticas foram projetadas em um software de CAD capaz de adaptar duas alturas diferentes do pilar de interface de Ti: cada grupo foi composto de 10 amostras conforme se segue: (i) interface de Ti de 4 mm de altura (alto) e (ii) interface de 2,5 mm de altura (curto). Foram selecionados quatro tipos de cimento: (i) cimento temporário (Provisional); (ii) Cimento de ionômero de vidro (Meron); (iii) cimento resinoso auto-adesivo (U200) e (iv) cimento resinoso convencional (Ultimate) com adesivo universal para tratamento de substratos de titânio e zircônia. O teste de tração foi realizado em uma máquina de ensaio universal. Os dados foram avaliados estatisticamente através de análise de variância a dois critérios, após comparações pós-hoc pelo teste de Tukey. Resultados: As interfaces de Ti demonstraram retenção semelhante aos pilares curtos quando os dados foram colapsados sobre o cimento (p> 0,74). A avaliação dos dados em função do tipo de cimento demonstrou a superioridade dos cimentos à base de resina em relação aos grupos de cimentos temporário e de ionômero de vidro (p <0,01). Os dados de retenção em função de ambos os fatores demonstraram força semelhante ao deslocamento, entre pilares altos e curtos, para todos dentro das comparações de cimento (p> 0,42), exceto para U200 (p = 0,032). Além disso, os pilares altos cimentados com Ultimate evidenciaram maiores valores de tração do que os cimentados com U200 (p = 0,043), e ambos foram significativamente mais retentivos do que o pilar alto cimentado com cimento Provisional e o Meron (p <0,001). Não foi observada diferença significativa entre os cimentos U200 e Ultimate para pilares curtos (p = 0,758) e ambos apresentaram valores de tração estatisticamente mais elevados que os cimentos de ionômero de vidro e cimento temporário (p = 0,001). Conclusões: Embora a altura da interface de Ti não tenha influenciado a retenção das coroas de zircônia, os cimentos resinosos resultaram em maior retenção do que o ionômero de vidro e cimentos temporários.
273

Características da deglutição em idosos submetidos a diferentes estratégias de reabilitação oral protética / Characteristics of swallowing in elderly individuals submitted to different strategies for prosthetic oral rehabilitation

Totta, Tatiane 29 August 2008 (has links)
O objetivo deste estudo foi verificar se diferentes estratégias de reabilitação oral protética acarretam modificações nos achados clínicos e videoendoscópicos da deglutição em idosos. Métodos: participaram da pesquisa 42 idosos saudáveis com desempenho cognitivo adequado (26 mulheres e 16 homens, 60-82 anos), desdentados totais ou parciais, separados em três grupos segundo avaliação odontológica prévia: próteses parciais fixas ou removíveis (PP) (n = 15); próteses totais removíveis superior e inferior (PTR) (n = 15); e próteses totais removíveis superior e próteses totais fixas implanto-suportadas inferior (PTFIS) (n = 12). O grupo controle foi constituído de 15 idosos dentados totais (DT) (6 homens e 9 mulheres, 60-80 anos) que atenderam aos critérios de inclusão na amostra. Avaliaram-se as consistências sólida (pão), pastosa (10 ml) e líquida (10 ml). Para a avaliação clínica propôs-se uma classificação da gravidade da disfunção da deglutição orofaríngea, distribuída em cinco níveis. Na avaliação instrumental, da qual participaram 37 idosos, realizou-se teste de sensibilidade laringofaríngea, e classificou-se a gravidade do distúrbio de deglutição, de acordo com a escala de comprometimento funcional (gravidade) da deglutição após a VED, ordenada em graus de 0 à III. Para a análise comparativa entre os grupos em ambas as avaliações, e para comparação entre os níveis de comprometimento da deglutição, utilizou-se o Teste de Kruskal-Wallis, adotando-se o nível de significância inferior a 5%. Resultados: Os achados clínicos e videoendoscópicos da deglutição demonstraram não haver diferenças estatisticamente significantes (p>0,05) entre os grupos estudados, nas três consistências ofertadas. Especificamente na avaliação clínica, para a consistência pastosa o grupo DT apresentou maior prevalência de deglutição funcional, enquanto a disfagia orofaríngea moderada foi o padrão de maior ocorrência no grupo PTR (p<0,01). Para o sólido, os grupos de reabilitação oral demonstraram predomínio das disfagias (p<0,01) em relação à deglutição normal e funcional, sendo predominante a disfagia orofaríngea moderada para o grupo PTR (p<0,01). A VED demonstrou, para todos os grupos, que na deglutição de líquido houve distribuição semelhante entre os níveis, enquanto nas consistências sólida e pastosa encontrou-se predomínio de disfagia (p<0,01), havendo maior ocorrência da disfagia orofaríngea moderada (p<0,01) para o grupo PTR na consistência pastosa. O teste de sensibilidade laringofaríngea demonstrou que 19 (51,35%) indivíduos apresentaram alteração da sensibilidade, sendo 6 (40%) do grupo PP, 7 (63,63%) do grupo PTR e 6 (54,54%) do grupo PTFIS. Conclusão: Idosos saudáveis podem apresentar diferentes níveis de deglutição, havendo maior ocorrência de disfagia orofaríngea para as consistências pastosa e sólida, sendo que diferentes estratégias de reabilitação oral não resultam em modificações no padrão de deglutição desses sujeitos. / This study investigated if different strategies of prosthetic oral rehabilitation cause changes in the clinical and videoendoscopic findings of swallowing in elderly individuals. Methods: The study was conducted on 42 healthy elderly subjects with adequate cognitive performance (26 women and 16 men, 60-82 years), completely or partially edentulous, divided in three groups according to the previous dental evaluation: wearing fixed or removable partial dentures (RPD) (n = 15); wearing maxillary and mandibular removable complete dentures (RCD) (n =15); and wearing maxillary removable complete dentures and mandibular implant-supported fixed complete dentures (ISFCD) (n = 12). The control group was composed of 15 completely dentate elderly individuals (DT) (6 men and 9 women, 60-80 years) who met the inclusion criteria. Solid (bread), paste (10 ml) and liquid (10 ml) food textures were analyzed. Clinical evaluation was performed by classification of the severity of dysfunction of oropharyngeal swallowing, divided in five scores. The instrumental evaluation was applied to 37 elderly individuals, comprising the laryngopharyngeal sensitivity test for classification of the severity of the swallowing disorder according to the scale of functional impairment (severity) of swallowing after the VED, divided in scores 0 to III. Comparison between groups in both evaluations and between the scores of impairment of swallowing was performed using the Kruskal-Wallis test, at a significance level below 5%. Results: The clinical and videoendoscopic findings of swallowing revealed no statistically significant differences (p>0.05) between the study groups, for the three textures. Specifically with regard to the clinical evaluation for the paste texture, the DT group exhibited higher prevalence of functional swallowing, while the RCD group presented higher occurrence of moderate oropharyngeal dysphagia (p<0.01). With regard to the solid texture, the groups of oral rehabilitation presented predominance of dysphagia (p<0.01) in relation to normal and functional swallowing, with predominance of moderate oropharyngeal dysphagia for the RCD group (p<0.01). The VED demonstrated, for all groups, that the swallowing of liquid had a similar distribution between scores, while for the solid and paste textures there was predominance of dysphagia (p<0.01), with higher occurrence of moderate oropharyngeal dysphagia (p<0.01) for the RCD group for the paste texture. The laryngopharyngeal sensitivity test demonstrated that 19 (51.35%) individuals presented alterations in sensitivity, being 6 (40%) in the RPD group, 7 (63.63%) in the RCD group and 6 (54.54%) in the ISFCD group. Conclusion: Healthy elderly individuals may present different scores of swallowing, with higher occurrence of oropharyngeal dysphagia for the paste and solid textures; different strategies of oral rehabilitation did not cause changes in the pattern of swallowing of these individuals.
274

Microtopografia de implantes de titânio com diferentes tratamentos de superfícies à microscopia eletrônica de varredura e de força atômica / Microtopography of titanium implants with different surface treatments scanning in electronic microscopy and atomic force microscopy

Moretti, Lívia Alves Corrêa 31 August 2012 (has links)
INTRODUÇÃO: A qualidade da interface osso-implante pode ser influenciada diretamente pela rugosidade da superfície e determina a forma como as células interagem, aderem-se e fixam-se a ela, podendo potencializar e encurtar o tempo de osseointegração. Este estudo propôs-se analisar qualitativamente a topografia e arquitetura de diferentes superfícies de implantes dentários, compará-las, descrevê-las e correlacioná-las com os possíveis eventos moleculares e celulares iniciais da osseointegração. MATERIAIS E MÉTODOS: cinco implantes com diferentes tratamentos de superfície foram analisados em três diferentes áreas: apical, região de roscas (topos, flancos e vales) e região cervical por microscopia eletrônica de varredura (MEV) e topo do ápice em microscopia de força atômica (MFA). RESULTADOS: as superfícies dos implantes NanoTite®, SLA® e Xive® TG plus, no MEV, são semelhantes pelo seu aspecto de lacunas, diferindo no plano superficial; a superfície do implantes TiUnite® apresenta características coraliformes/vulcanoides, enquanto a do implante Exopro® apresenta estrias em formas de pequenos sulcos. A rugosidade média (Ra) à MFA, apresentou-se maior no implante TiUnite®, seguido pelos implantes Xive®TG plus, NanoTite®, Exopro® e SLA®. A área analisada se restringe a pequenos pontos (nanométricos), que não possibilita uma visão panorâmica de todas as estruturas (micrométricas), e consequentemente não permite uma real comparação da rugosidade. CONCLUSÕES: a metodologia ideal para análise das superfícies com o objetivo de compreender como as células às colonizam e se aderem deve ser em escala micrométrica, destacando-se à MEV em detrimento da MFA. As duas metodologias, MEV e MFA, são fundamentais na análise de superfície de implantes dentários, porém devem ser conjuntamente e/ou simultaneamente empregadas. A MFA parece ser a mais adequada para estudos que visem a interação da superfície dos implantes com estrutura de nível molecular e à MEV, no nível celular. Cada tratamento de superfície promove um tipo específico de topografia, cujos benefícios moleculares, teciduais e clínicos devem ser estudados caso a caso. / Introduction: Bone-implant interface quality may be influenced by surface roughness and determines how cells interact, cling to and fix to, therefore can enhance and shorten the time for osseointegration. This study aims to analyze qualitatively the topography and architecture of different dental implants surfaces, to compare and describe them. MATERIALS AND METHODS: five implants with different surface treatments were evaluated in three different areas: apical, region of threads (tops, sides and valleys) and cervical region by scanning electron microscopy (SEM) and atomic force microscopy (AFM), correlating the possible molecular and cellular initials events of osseointegration. RESULTS: the surfaces of the implants NanoTite®, SLA® and ® Xive® TG plus, in the SEM, are similar by their appearance of gaps, although they differ in surface plane; the surface of TiUnite® implants have features such as corals and/or volcanos, while the implant Exopro ® has stretch marks in form of small grooves. The average roughness (Ra) to the AFM, appeared higher in TiUnite ® implant, followed by Xive® TG plus NanoTite®, Exopro® and SLA® implants. The area analyzed in the AFM, is restricted to small points (nanometrics), and do not allow denote a panoramic view of all structures (micrometrics), not allowing a real comparison of surface roughness. CONCLUSIONS: the optimal methodology for surfaces analysis with the objective of understanding how the cells colonize and fix to dental implants should be in the micrometer scale, highlighting the SEM over AFM. The AFM seems to be most suitable for studies aiming the interaction of the implant surface with molecular-level and SEM at the cellular level. Each treatment promotes a specific surface topography whose benefits molecular, tissue, and clinical should be studied separately.
275

Avaliação da infiltração bacteriana através da interface implante-conector protético sob aplicação de carga - avaliação in vitro pelo método DNA Checkerboard / Bacterial leakage along the implant-abutment interface after loading simulation. In vitro evaluation by DNA Checkerboard method

Nascimento, Cássio do 03 September 2010 (has links)
A passagem bacteriana através da interface entre implante e conector protético com a conseqüente colonização dos implantes tem sido relatada em diversos estudos na literatura. O objetivo deste estudo in vitro foi avaliar a passagem de espécies bacterianas da saliva humana para o interior dos implantes através da interface implante-conector protético após simulação de carga cíclica controlada. Foram avaliados 60 implantes de um sistema de 2 componentes e seus respectivos conectores protéticos, divididos em 3 grupos de acordo com o tipo de conexão utilizado: hexágono externo, hexágono interno e cone morse. Cada grupo foi dividido em 2 subgrupos (n=10), submetidos à aplicação de carga e controle. Previamente ao teste, amostras do interior dos implantes foram coletadas para servirem como controle negativo da contaminação. Os conectores foram adaptados aos implantes com um torque final de 20 Ncm, de acordo com a recomendação do fabricante. Os conjuntos foram imersos em saliva humana e submetidos a 500.000 ciclos de carga com uma força de 120 N ou incubados em 35°C durante 7 dias sem aplicação de carga (controle). A eventual contaminação do interior dos implantes foi avaliada após o período experimental usando o método DNA Checkerboard. Microrganismos foram encontrados no interior dos implantes de todos os tipos de conexões avaliadas após o teste de carga cíclica. Os grupos cone morse apresentaram os menores valores de contagem bacteriana nos grupos submetidos a ciclagem de carga e controle. Os implantes submetidos à carga cíclica apresentaram maiores valores de contagem bacteriana do que seus respectivos controles no hexágono externo e interno. Nenhuma espécie bacteriana foi encontrada abrigando o interior dos implantes antes do teste de contaminação (controle negativo). Os implantes do grupo cone morse apresentaram menores quantidades de microrganismos nas duas condições testadas. Pode-se concluir que espécies bacterianas provenientes da saliva humana podem penetrar através da interface implante-conector protético com ou sem a simulação de carga cíclica, e que a aplicação de carga contribuiu para o aumento da contaminação nos implantes com conexão hexagonal externa e interna. / Bacterial leakage along the implant-abutment interface with consequent species harboring the inner parts of two-part dental implant systems has been reported. The aim of this in vitro study was to evaluate the bacterial leakage from human saliva to the internal part of the implants along the implant-abutment interface under loading conditions. Sixty dental implants, 20 for each external or internal hexagon and morse cone connection, and their conical abutments were used in this study. Each connection was sub-divided in 2 groups (n=10), loaded implants and control (unloaded). Previously to the bacterial leakage test, samples from the inner parts of the implants were collected with sterile microbrushes as negative control of contamination. The abutments were tightened to 20 Ncm on the implants. The assemblies were immersed in human saliva and loaded with 500,000 cycles of 120 N in experimental or incubated for 7 days at 35°C in control group. After this period, possible contamination of the internal parts of the implants was evaluated using the DNA Checkerboard method. Microorganisms were found in the internal surfaces of all connections evaluated. Morse cone connection presented the lowest count of microorganisms in control and loading group. Loaded implants present higher counts of microorganisms than control group in external and internal hexagon. No microorganisms were found in the samples recovered from the implants before contamination test (negative control). It can be concluded that bacterial species from human saliva may penetrate along the implant-abutment interface under unloaded and loaded conditions, and morse cone connection presented the lowest count of microorganisms.
276

Avaliação radiográfica do comportamento ósseo em relação à profundidade da linha marginal de cimentação de próteses sobre implantes Cone Morse: estudo experimental em cães / Radiographic evaluation of bone behavior in relation to the depth of the line of marginal cementation of prostheses on Morse taper implants: experimental study in dogs

Stancari, Fernanda Herrera 29 March 2011 (has links)
Pouco se sabe sobre o comportamento do tecido ósseo em relação à profundidade da linha de cimentação em próteses sobre implantes. Por isso, o presente estudo radiográfico utilizou os implantes Cone Morse com o intuito de definir a posição exata na qual se pode estabelecer a profundidade da linha de cimentação protética. Foram utilizados cinco cães, os quais tiveram todos os pré-molares inferiores extraídos numa primeira fase cirúrgica. Após três meses, realizou-se a segunda fase cirúrgica na qual foi utilizada a técnica da carga imediata, com a instalação dos implantes juntamente com os pilares protéticos. Foram instalados trinta implantes numa profundidade de 3mm infra óssea e eles foram igualmente divididos entre os grupos Controle e Experimental. Os pilares protéticos tinham diferentes dimensões transmucosas de 1.5, 3.5, e 5.5mm. Isto fez com que a linha de cimentação se posicionasse a 1.5mm infra óssea, a 0.5mm supra óssea e a 2.5mm supra óssea. No grupo Controle, foi realizada a instalação dos implantes e dos pilares protéticos somente. No grupo Experimental, foi realizada a instalação dos implantes, dos pilares protéticos e, sobre estes, foram cimentados cilindros de alumina. Foram realizadas tomadas radiográficas periapicais, através da técnica do paralelismo, em todas as fases do experimento. As radiografias foram escaneadas e analisadas através do programa AutoCAD. Foram utilizados os testes estatísticos t de Student para amostras pareadas e independentes com o nível de significância de p<0.05. Os resultados mostraram que não houve diferenças estatisticamente significantes entre os grupos Controle e Experimental nas diferentes profundidades em relação ao tecido ósseo. Adicionalmente, também não houve diferenças estatisticamente significantes na crista óssea nas variações das dimensões das cintas transmucosas dos pilares testados e nas variações entre os tempos Inicial e Final do experimento no grupo Controle e no grupo Experimental. Conclui-se que não há influência da profundidade da linha de cimentação no comportamento da crista óssea e a utilização de diferentes dimensões dos pilares protéticos não altera o tecido ósseo marginal ao redor dos implantes Cone Morse. / Little is known about the behavior of bone tissue in relation to the depth of the cement line position in dental implants. Therefore, this radiographic study used the Morse taper implants in order to define the exact location in which it can be established the depth of the prosthetic cementation line. Five dogs were used and had all their lower premolars extracted in the first stage surgery. After three months, was performed a second surgical procedure in which was used the technique of immediate loading, installing together implants and abutments. Thirty implants were installed at a depth of 3 mm below the bone and they were equally divided between the Control and Experimental group. The abutments had different transmucosal dimensions of 1.5, 3.5, and 5.5mm. This meant that the depth of cementation line was positioned respectively to 1.5mm below the bone, 0.5 above the bone and 2.5mm above the bone. In the Control group, was performed the installation of implants and abutments only. In the Experimental group, was performed the installation of implants, abutments and, over these, was cemented cylinders of alumina. Periapical radiographs were taken, using the paralleling technique, in all phases of the experiment. The radiographs were scanned and analyzed with the program AutoCAD. Statistical t Student test of samples paired and independent were used with the level of significance of p<0.05. The results showed no differences statistically significants between the Control and Experimental group at different depths in relation to bone tissue. Additionally, there were no differences statistically significant in the crest bone in the variations of dimensions of the transmucosal abutments tested and in the variations between the Start and End time of the experiment in the Control and Experimental groups. It is concluded that there is no influence of the depth of cementation line on the behavior crest bone and the different dimensions of the abutment does not change the marginal bone around Morse taper implants.
277

Efeito do jateamento de óxido de alumínio e uso de selante industrial, na superfície de pilares protéticos Cone Morse, de restaurações implanto suportadas sobre a resistência ao contratorque / Effect of aluminum oxide blasting and use of industrial sealant on the outer abutment surface of the prosthetic morse taper system connection on the untightening torque

Tunes, Fábio Sanches Magalhães 18 June 2012 (has links)
Problemas com desenho de conexões protéticas sobre implantes, microfendas, afrouxamento e, consequentemente, perdas das estruturas protéticas reabilitadoras são tópicos frequentes do estudo odontológico. Conexões do tipo Cone Morse, devido às suas características, diminuíram o índice desses problemas, abrindo uma nova perspectiva para o sucesso da prótese sobre implante. Contudo, ainda é frequente encontrar componentes que falham no desempenho, levando à falência da restauração, especialmente quando esses componentes não são bem ajustados, bem fixados ou, ainda, não possuem, na sua geometria, características suficientes para suportar as forças laterais e oclusais de um ciclo mastigatório. O objetivo deste estudo é avaliar a influência do jateamento com óxido de alumínio sobre a superfície externa dos componentes protéticos, separadamente e em conjunto, com um adesivo industrial, em uma tentativa de aumentar os valores de torque de abertura de componentes apertados em seu torque recomendado, pelo fabricante ou menor. Neste ensaio, foram utilizados 36 implantes da marca Straumann®, de 10mm de comprimento com diâmetro de 4,8 mm, os quais foram divididos em 6 grupos: Grupo 1 = controle, torque de 35 N.cm; Grupo 2 = superfície jateada com óxido de alumínio (# 320) e torque de 35 N.cm; Grupo 3 = superfície jateada com óxido de alumínio (# 320) e torque de 25 N.cm; Grupo 4 = superfície jateada com óxido de alumínio (# 100) e torque de 25 N.cm; Grupo 5 = superfície jateada com óxido de alumínio (# 320), aplicação de adesivo e torque de 25 N.cm; Grupo 6 = superfície jateada com óxido de alumínio (# 100), aplicação de adesivo e torque de 25 N.cm, que receberam componentes protéticos sólidos de 5,5 mm de altura, regulares e alterados. As modificações incluídas foram o jateamento com partículas de óxido de alumínio (100 e 320 micra) e o uso de Loctite® 277 como adesivo industrial. Os conjuntos implante-componente foram levados até uma máquina de controle de tração, Instron®, e, após a sua calibração, as amostras dos grupos foram apertadas em 35 e 25 N.cm, com um conjunto catraca-torquímetro, com checagem visual e registro no software acoplado à máquina de ensaio. Após trinta dias, os grupos foram levados à máquina novamente e o conjunto abutment-implante foi desapertado, agora somente com registro no software da máquina de ensaio. Os valores e porcentagens da diferença entre torque de aperto e desaperto foram avaliados estatisticamente, e comparados entre os grupos. Para todas as associações, o valor de p deveria ser menor ou igual 0,05, para relevância. O grupo Jateado 35 N.cm, 320 micra, não apresentou valores mais altos do que o grupo Controle no momento do torque de desaperto, assim como os grupos Jateados 25 N.cm 100 e 320 micra. Os grupos Jateados 25 N.cm, 100 e 320 micra, com adesivo, mostraram uma resistência por volta de uma vez e meia maior, no torque de desaperto do que o grupo Controle 35 N.cm. / Problems with design of prosthetic implant connections, microleakage,! loosening which leads to loss of rehabilitative prosthetic structures are frequent topics of dental study. Morse taper connections, due to its characteristics, decreased the rate of these problems opening a new perspective to the success of the prosthesis supported over implant. However, it is still frequent to find components that fail in performance leading to failure of restoration especially when these components are not well adjusted, tightened or do not have in its geometry enough characteristics to support the occlusal and lateral forces in a masticatory cycle. The aim of this study is to evaluate the influence of blasting with aluminum oxide on the outer surface of the prosthetic components separately and in conjunction with an industrial adhesive in an attempt to increase the opening torque values of components tightened on their recommended torque by the manufacturer or less, therefore allowing the dentist an early intervention in the prosthetic rehabilitation. In this test, 36 Straumann® implants of 10mm high and 4,8mm wide were used. They were divided into six groups: Group 1 Solid abutments control group - 35 N.cm tightened; Group 2 - Solid sandblasted abutments, 35 N.cm aluminum oxide 320 microns size particles; Group 3 - Solid sandblasted abutments, 25 N.cm aluminum oxide 320 microns size particles; Group 4 - Solid sandblasted abutments, 25 N.cm aluminum oxide 100 microns size particles; Group 5 - Solid sandblasted abutments, 25 N.cm aluminum oxide 320 microns size particles with glue application; Group 6 - Solid sandblasted abutments, 25 N.cm aluminum oxide 100 microns size particles with glue application, which received 5,5 mm high regular and modified solid abutments. The included modifications were sandblasting with aluminum oxide particles (100 and 320 microns) and the use of Loctite® 277 as an industrial adhesive. The samples were taken to a traction control test machine, Instron ®, and after calibration the group samples were tightened on 35 and 25 N.cm with a ratchet-wrench set with visual check. The data was recorded in a software coupled to the test machine. After thirty days the groups were brought again to the test machine and the samples were untightened. At this point the resulting data was recorded only in the testing machine software. The values and percentages of the changes between the tightening and loosening torques were recorded and compared among the study groups. For all associations a p-value < 0.05 was considered significant. The group blasted 35 N.cm, 320 microns did not show higher values than the control group at the time of loosening torque as well as groups blasted 25 N.cm 100 and 320 microns. The groups blasted 25 N.cm, 100 and 320 microns with adhesive showed a resistance around one and a half times greater in the loosening torque than the control group 35 N.cm.
278

Ultrassom de alta frequência para avaliação da tábua óssea vestibular de implantes dentais / High frequency ultrasound for evaluation of buccal bone surrounding dental implants

Bohner, Lauren Oliveira Lima 25 July 2017 (has links)
Objetivo: Avaliar a exatidão do ultrassom de alta frequência na mensuração das dimensões lineares tanto da tábua óssea vestibular como de defeitos periimplantares circundando implantes dentais. Materiais e Métodos: Em uma primeira etapa, implantes dentais (n=10) foram instalados na maxila de 3 crânios secos e escaneados com ultrassom de alta frequência (UAF) e tomografia computadorizada de feixe cônico (TCFC). As seguintes medidas lineares foram determinadas para avaliação: A) espessura óssea; B) nível ósseo. As medições foram comparadas com valores de referência determinados pela microscopia óptica. A segunda etapa do experimento envolveu amostras de osso porcino contendo defeitos ósseos ao redor dos implantes dentais (n=10), as quais foram escaneadas com ultrassom de alta frequência e tomografia computadorizada de feixe cônico. As seguintes medidas foram realizadas nos defeitos periimplantares: A) componente supra-alveolar, B) componente intra-ósseo e C) espessura do defeito. Os valores de referência foram determinado pela microtomografia computadorizada e o erro de medição (diferença entre grupo teste e controle) foi determinado. Os dados foram analisados estatisticamente considerando um nível de significância de p<=0.05. Resultados: Não houve diferença estatisticamente significante entre os grupos para as medições da espessura óssea e nível ósseo (p>0.05). Em relação à espessura óssea, a discrepância foi de 0.17mm para o UAF e 0.02mm para a TCFC. Para o nível ósseo, a discrepância foi de 0.55mm para o UAF e 0.12mm para a TCFC. Ao considerar o erro de medição dos equipamentos na mensuração de defeitos periimplantares, não houve diferença estatisticamente significante entre o UAF e TCFC (UAF= 0.54±0.69mm; TCFC= 0.62±0.55mm). Conclusão: O ultrassom de alta frequência apresentou exatidão para a mensuração das dimensões lineares da tábua óssea vestibular e de defeitos periimplantares circundando implantes dentais. / Purpose: To evaluate the accuracy of a high frequency ultrasound scanner (HFU) to the measurement of buccal bone and periimplant defects surrounding dental implants. Materials and Methods: The first phase of this study comprised the installation of dental implants (n=10) in the maxillary of 3 dry skulls. The dental implants were scanned with a high frequency ultrasound scanner and a cone-beam computed tomography (CBCT). The following measurements were determined for evaluation: A) bone thickness, and B) bone level. The measurements were compared with reference values determined by an optical microscopy. The second phase comprised the installation of dental implants (n=10) in porcine bone samples containing bone defects surrounding dental implants. The bone samples were scanned with a high frequency ultrasound and cone-beam computed tomography and the following measurements were performed: A) supra-alveolar component, B) intra-bony component and C) thickness. The reference values were determined by a micro-computed tomography and the measurement error (difference between experimental and control group) was determined for each group. All measurements were statistically analyzed with a significance level of p<=0.05. Results: There was no statistically significant difference between ultrasound and cone-beam computed tomography for the measurement of buccal bone (p>0.05). With regard to the bone thickness, the discrepancy to the reference values was 0.17mm for HFU and 0.02mm for CBCT. For bone level, the discrepancy was 0.55mm for HFU and 0.12mm for CBCT. The measurement error from both the devices not differed statistically (HFU= 0.54±0.69mm; CBCT= 0.62±0.55mm). Conclusion: The high frequency ultrasound presented accuracy for the measurement of buccal bone and periimplant defects surrounding dental implants.
279

O bombardeamento da superfície de titânio com íons de argônio influencia a resposta biológica de pré-osteoblastos / Argon ions bombardment of titanium surface influences preosteoblastic biological behavior

Moura, Carlos Eduardo Bezerra de 14 December 2007 (has links)
As propriedades da superfície do implante têm papel crítico na indução das respostas celulares necessárias para o sucesso do implante. Os objetivos deste trabalho foram investigar o efeito do bombardeamento com íons de argônio sobre a superfície de titânio comercialmente puro (TiCP) e sua influencia na interação célula-superfície. Superfícies bombardeadas e lisas foram avaliadas quanto à topografia, rugosidade e molhabilidade. Ensaios de adesão, proliferação, atividade de fosfatase alcalina (ALP) e expressão de osteocalcina (OC) foram conduzidos usando células MC3T3-E1 cultivadas sobre essas duas diferentes superfícies. Os níveis de rugosidade na superfície bombardeada e lisa foram 0,11µm and 0,027µm, respectivamente. A Microscopia eletrônica de Varredura (MEV) e Microscopia de força atômica (AFM) também revelaram rugosidade uniforme nestas amostras. A molhabilidade foi maior na superfície bombardeada. O número de células aderidas (30 e 60 min) foi significativamente maior sobre a superfície bombardeada. A proliferação celular depois de 3 e 7 dias também foi maior na superfície bombardeada. A atividade de ALP e expressão de OC não apresentaram diferença significativa entre as superfícies. Esses dados nos levam a propor que a técnica processamento a plasma em atmosfera de argônio com uso de cátodo planar é uma excelente ferramenta para obtenção de biomateriais que favoreçam a osseointegração. / Titanium surfaces were modified by argon ions bombardment aiming to evaluate the influence of the treatment on cell-surface interaction. The effects of topographic (roughness, microstructure) and physiochemical (wettability - contact angle) parameters on the morphology, adhesion, proliferation and MC3T3-E1 preosteoblasts differentiation were analyzed. No-treated surfaces (smooth) were used as a control. The levels of roughness observed in bombarded and smooth titanium surfaces were of 0.11µm and 0.027µm respectively. Scanning electron microscopy (SEM) and atomic force microscopy (AFM) analysis showed that the roughness distribution was uniform. The wettability increased in treated surfaces. The number of attached cells (30 and 60min) was significantly higher on the bombarded surface, as well as, cell proliferation after 3 and 7 days was also significantly higher on ion-bombarded surface. The ALP activity and OC expression did not show not significant differences between the surfaces. Based on the results showed one can propose that the bombardment of titanium surfaces with argon ions is an excellent procedure for obtaining biomaterials and improve the osseointegration.
280

Avaliação da deformação gerada na região peri-implantar de prótese fixa implantossuportada, com a utilização de extensômetros lineares elétricos / Evaluation of peri-implant bone deformation of a mandibular cantilevered implant-supported prosthesis, with the use of strain gages

Suedam, Valdey 07 August 2009 (has links)
O comportamento mecânico das próteses parciais fixas implanto-suportadas são foco de vários estudos, onde o entendimento do processo de transmissão de forças mastigatórias e suas reações na estrutura óssea peri-implantar ainda não são totalmente compreendidos. Por isso, o objetivo deste trabalho foi verificar a deformação gerada na região peri-implantar de prótese parcial fixa mandibular. Para isto foi utilizado um modelo de poliuretano em forma de U simulando o osso mandibular com dois implantes hexágono externo de 3,75mm de diâmetro por 13mm de comprimento, nos quais foram fixados intermediários multi-unit. O trabalho apresentou dois grupos divididos de acordo com o tipo de liga das infraestruturas (CoCr ou PdAg) os quais foram submetidos a quatro situações de aplicação de carga. Foram aplicadas forças de 300N, nos pontos de referência pré-determinados na barra entre os implantes e na extremidade livre (5mm, 10mm e 15mm de cantilever). Foram realizadas leituras das deformações geradas na distal, lingual, mesial e vestibular de cada implante, com o uso de extensômetros lineares elétricos, as quais foram correlacionadas com a teoria de remodelação óssea proposta por Frost. Os resultados do estudo demonstraram que a deformação é influenciada pelo ponto de aplicação de carga e pelo módulo de elasticidade da liga da barra. A deformação é diretamente proporcional ao comprimento do cantilever, onde comprimentos maiores do que 10mm provocam tensões que superam a tensão máxima fisiológica proposta pela teoria de Frost. / The mechanical behavior of implant-supported prosthesis is focus of some studies, with the process of bite forces transmissions and its peri-implant bone reactions is not completely understood yet. Therefore, the aim of this study was to verify the deformation in peri-implant region of mandibular fixed partial prosthesis. A U shaped polyurethane model was used to simulated the mandibular bone with two external hexagon implants with 3.75mm of diameter an 13mm of length, provided with multi-unit abutments. Two groups were formed according to the type of alloy of the framework (CoCr or PdAg), which were submitted to four load conditions. Loads of 300N were applied, in the predetermined points on the framework between the implants and the cantilever (5mm, 10mm and 15mm distal to the terminal implant). Readings of the deformations generated on the distal, lingual, mesial and bucal aspects of each implant were obtained with the use of strain gages, which were correlated to the theory proposed by Frost on bone remodeling. The results of the study demonstrated that deformation is influenced by the point of load application and by the elastic modulus of the alloy of the framework. The deformation is directly proportional to the cantilever length. Lengths bigger than 10mm generate tensions that exceed the maximum effective strain proposed by Frost.

Page generated in 0.4795 seconds