• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 552
  • 114
  • 20
  • 18
  • 18
  • 17
  • 17
  • 10
  • 10
  • 9
  • 8
  • 4
  • 3
  • 2
  • 2
  • Tagged with
  • 738
  • 738
  • 508
  • 475
  • 153
  • 135
  • 122
  • 109
  • 90
  • 76
  • 76
  • 74
  • 72
  • 70
  • 60
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
281

Avaliação da passagem de micro-organismos por meio da interface entre implantes e conectores protéticos com parafusos convencionais planos e experimentais cônicos pela técnica DNA-Checkerboard / Evaluation of microorganisms leakage through the interface between implants and prosthetic connectors with conventional plane and experimental conical screws by DNA-Checkerboard technique

Carla Gabaldo Pessoa dos Santos 03 March 2017 (has links)
Apesar da confiabilidade e da sobrevivência relacionadas aos tratamentos com implantes, falhas das reabilitações orais implanto-suportadas ainda são persistentes. Estas falhas podem causar tanto danos mecânicos -como o afrouxamento do parafuso de retenção devido à instabilidade das conexões- quanto danos biológicos -como as reações inflamatórias nos tecidos peri-implantares devido à ocorrência de infiltração bacteriana através da interface implante/pilar e a consequente colonização do interior dos implantes e seus componentes. Os mecanismos responsáveis por estas falhas mecânicas/biológicas dos sistemas de implantes não estão totalmente elucidados, e modificações nos modelos das conexões protéticas e dos parafusos de retenção vêm sendo desenvolvidas com o intuito de aumentar a estabilidade das conexões e minimizar estas intercorrências. Entretanto, a literatura relativa à configuração ideal destas modificações e seus fatores determinantes envolvidos ainda é inconclusiva. Assim, os objetivos do presente do estudo foram avaliar microbiologicamente por meio da técnica de hibridização DNA-Checkerboard, a ocorrência de infiltração bacteriana do meio externo para o interior dos implantes através das diferentes interfaces implante/pilar em dois diferentes sistemas de conexão de implantes, hexágono externo (HE) e triângulo interno (TI), com parafusos de retenção de pilares planos convencionais e parafusos experimentais cônicos. Quarenta e oito implantes dos dois tipos de conexão foram analisados, sendo estes HE ( n = 24) ou TI (n = 24). Os pilares foram fixados a implantes com parafusos convencionais ou parafusos cônicos experimentais. Após a incubação em saliva, a hibridização DNA Checkerboard foi utilizada para identificar e quantificar até 38 espécies bacterianas na área interna dos implantes. Para análise estatística utilizou-se o teste de Kruskal-Wallis seguido de pós-testes de Bonferroni para comparações múltiplas. Vinte e quatro das trinta e oito espécies estudadas, incluindo patógenos putativos periodontais, foram encontradas colonizando as superfícies internas dos implantes HE e TI. Peptostreptococcus anaerobios (P = 0,003), Prevotella melaninogenica (P <0,0001) e Candida dubliniensis (P <0,0001) apresentaram diferenças significativas entre os diferentes grupos. As médias de contagem microbiana total (× 104, ± DP) para cada grupo foram registradas como: G1 (0,27 ± 2,04), G2 (0 ± 0), G3 (1,81 ± 7,50) e G4 (0,35 ± 1,81). As diferentes geometrias das conexões de implantes e parafusos apresentaram distintos níveis de penetração microbiana através da interface implante-pilar. Os implantes ligados com parafusos de pilar de cabeça cônica experimental apresentaram contagens menores de micro-organismos quando comparados com os parafusos convencionais. / Despite the reliability and high success rates related to treatment with implants, failures of implant-supported oral rehabilitation are still persistent. These failures can cause both mechanical damage, such as loosening the retaining screw connections due to instability, as biological damage, such as inflammatory reactions in periimplants tissues due to the occurrence of bacterial leakage along the implant/abutment interface and the subsequent colonization of the subsequent colonization of the internal/inner parts of the implants and components. The mechanisms responsible for these mechanical/biological failures of implant systems are not fully elucidated, and changes to the models of prosthetic connections and retaining screws have been developed in order to increase the stability of connections and minimize these problems. However, the literature related to these changes and its impact on the implant-components stability is still inconclusive. The objective of this study was to evaluate microbiologically by the DNA-Checkerboard hybridization, the occurrence of bacterial leakage from the external environment to the interior of the implant through these different implant/abutment interface. For the study will be evaluated two different implant connections, one external hexagonal (EH) and other internal triangle (IT), with either conventional and experimental tapered screws abutment. Forty-eight two-part implants with external hexagon (EH; n = 24) or tri-channel internal (TI; n = 24) connections were investigated. Abutments were attached to implants with conventional flat-head or experimental conical-head screws. After saliva incubation, Checkerboard DNA-DNA hybridization was used to identify and quantify up to 38 bacterial colonizing the internal parts of the implants. Kruskal-Wallis test followed by Bonferroni\'s post-tests for multiple comparisons was used for statistical analysis. Twenty-four of thirty-eight species, including putative periodontal pathogens, were found colonizing the inner surfaces of both EH and TI implants. Peptostreptococcus anaerobios (P = 0.003), Prevotella melaninogenica (P < 0.0001), and Candida dubliniensis (P < 0.0001) presented significant differences between different groups. Means of total microbial count (×104 , ±SD) for each group were recorded as follows: G1 (0.27 ± 2.04), G2 (0 ± 0), G3 (1.81 ± 7.50), and G4 (0.35 ± 1.81). Differences in the geometry of implant connections and abutment screws have impacted the microbial leakage through the implant-abutment interface. Implants attached with experimental conical-head abutment screws showed lower counts of microorganisms when compared with conventional flat-head screws.
282

Avaliação da infiltração bacteriana através da interface implante-conector protético sob aplicação de carga - avaliação in vitro pelo método DNA Checkerboard / Bacterial leakage along the implant-abutment interface after loading simulation. In vitro evaluation by DNA Checkerboard method

Cássio do Nascimento 03 September 2010 (has links)
A passagem bacteriana através da interface entre implante e conector protético com a conseqüente colonização dos implantes tem sido relatada em diversos estudos na literatura. O objetivo deste estudo in vitro foi avaliar a passagem de espécies bacterianas da saliva humana para o interior dos implantes através da interface implante-conector protético após simulação de carga cíclica controlada. Foram avaliados 60 implantes de um sistema de 2 componentes e seus respectivos conectores protéticos, divididos em 3 grupos de acordo com o tipo de conexão utilizado: hexágono externo, hexágono interno e cone morse. Cada grupo foi dividido em 2 subgrupos (n=10), submetidos à aplicação de carga e controle. Previamente ao teste, amostras do interior dos implantes foram coletadas para servirem como controle negativo da contaminação. Os conectores foram adaptados aos implantes com um torque final de 20 Ncm, de acordo com a recomendação do fabricante. Os conjuntos foram imersos em saliva humana e submetidos a 500.000 ciclos de carga com uma força de 120 N ou incubados em 35°C durante 7 dias sem aplicação de carga (controle). A eventual contaminação do interior dos implantes foi avaliada após o período experimental usando o método DNA Checkerboard. Microrganismos foram encontrados no interior dos implantes de todos os tipos de conexões avaliadas após o teste de carga cíclica. Os grupos cone morse apresentaram os menores valores de contagem bacteriana nos grupos submetidos a ciclagem de carga e controle. Os implantes submetidos à carga cíclica apresentaram maiores valores de contagem bacteriana do que seus respectivos controles no hexágono externo e interno. Nenhuma espécie bacteriana foi encontrada abrigando o interior dos implantes antes do teste de contaminação (controle negativo). Os implantes do grupo cone morse apresentaram menores quantidades de microrganismos nas duas condições testadas. Pode-se concluir que espécies bacterianas provenientes da saliva humana podem penetrar através da interface implante-conector protético com ou sem a simulação de carga cíclica, e que a aplicação de carga contribuiu para o aumento da contaminação nos implantes com conexão hexagonal externa e interna. / Bacterial leakage along the implant-abutment interface with consequent species harboring the inner parts of two-part dental implant systems has been reported. The aim of this in vitro study was to evaluate the bacterial leakage from human saliva to the internal part of the implants along the implant-abutment interface under loading conditions. Sixty dental implants, 20 for each external or internal hexagon and morse cone connection, and their conical abutments were used in this study. Each connection was sub-divided in 2 groups (n=10), loaded implants and control (unloaded). Previously to the bacterial leakage test, samples from the inner parts of the implants were collected with sterile microbrushes as negative control of contamination. The abutments were tightened to 20 Ncm on the implants. The assemblies were immersed in human saliva and loaded with 500,000 cycles of 120 N in experimental or incubated for 7 days at 35°C in control group. After this period, possible contamination of the internal parts of the implants was evaluated using the DNA Checkerboard method. Microorganisms were found in the internal surfaces of all connections evaluated. Morse cone connection presented the lowest count of microorganisms in control and loading group. Loaded implants present higher counts of microorganisms than control group in external and internal hexagon. No microorganisms were found in the samples recovered from the implants before contamination test (negative control). It can be concluded that bacterial species from human saliva may penetrate along the implant-abutment interface under unloaded and loaded conditions, and morse cone connection presented the lowest count of microorganisms.
283

Osteoblastic cell adhesion on implant surfaces contaminated by Aggregatibacter actinomycetencomitans and treated by photodynamic therapy and chemical decontamination / Adesão de células osteoblásticas em superfícies de implantes contaminadas por Aggregatibacter actinomycetencomitans e tratadas com terapia fotodinâmica e descontaminação química

Balderrama, Ísis de Fátima 06 April 2018 (has links)
The decontamination process of titanium implants surface is important for the successful treatment of peri-implantitis. The methods of decontamination can be classified in two major groups: chemical or physical. However, the best method of decontamination of implant surfaces is yet undertermined. The aim of this study is to analyze the effectiveness of decontamination of titanium implants surface by chemical conditioning agents and photodynamic therapy, by Scanning Electron Microscopy (SEM) and to analyze the adhesion and proliferation of osteoblastic cells on the previously decontaminated surfaces. Commercially available implants of different brands: Biomet 3i® (Nanotite NT; Osseotite - OT), Straumann® (SLActive SLA) and Neodent® (Acqua Drive CM ACQ; Neoporos Drive CM CM) were acquired in the market and analyzed in SEM images in 3 different areas (n= 1/group) to determine surface roughness parameters and wettability properties. After that, the surface of dental implants was inoculated with Aggregatibacter actinomycetemcomitans (A.a.) strains for 4 days and prepared for SEM analysis to determine the percentage area of contamination in a software for image analysis. Samples were then decontaminated by two different chemical treatments (citric acid 10% and ethylenediamine tetraacetic acid EDTA - 24%) and photodynamic therapy (methylene blue associated with LASER), both with a 3-minutes application time. In the control group, surfaces were decontaminated with chlorhexidine 0.12% for 3 minutes. The area of decontamination was determined in ImageJ software for SEM images analysis. After decontamination, the adhesion and proliferation of human osteoblastic osteosarcoma cell lineage (Saos-2) on the surface of uncontaminated sterile implants (control; n: 1/period) and decontaminated implants (n: 3/period/group) were investigated. Saos-2 cells [5x104] were seeded on implant surfaces and incubated for 24h (adhesion assay) and 72h (proliferation assay), determined on SEM images. No significant differences were found among the different implants regarding roughness parameters, with exception Rv (SLA: 19.57}4.01 vs. OT: 8.36}7.91; p=0.0031). Chemical composition varied among implants depending on surface treatment, with all groups showing prevalence of Titanium. Values showed greater contact angle (wettability analysis) for NT (hydrophobic) and smaller for ACQ (highly hydrophilic) (p<0.0001). Nanotite/Biomet 3i® showed significantly greater percentage of area contaminated by bacteria (68.19% } 8.63%; p=0.050; Kruskal Wallis/Dunn) than ACQ (57.32% } 5.38%). Osseotite/Biomet 3i® resulted in a smaller remaining contaminated area (50.89% } 9.12%) after decontamination treatments. Increased Saos-2 cells adhesion and proliferation were observed on SLA after 24h (p= 0.0006; ANOVA/Tukey) and 72h (<0.001; ANOVA/Tukey). Decontaminated groups showed significantly less number of cells adhered to the surfaces at 24h and 72h than uncontaminated controls (p < 0.005; ANOVA post hoc Sidak). Regarding decontamination methods, no differences in the number of cells attached to implants treated by photodynamic therapy and chemical agents compared to chlorhexidine at 24h, but implants treated by photodynamic therapy and chemical agents showed greater number of cells attached after 72h. These findings suggest that surface characteristics influenced bacterial contamination and decontamination of implant surfaces; none of the decontamination methods were able to completely remove bacterial contamination, impairing cell adhesion and spreading. These findings may explain the varying clinical results of decontamination methods in re-osseointegration. / O processo de descontaminação de implantes de titânio é importante para o sucesso do tratamento da peri-implantitite. Os métodos de descontaminação podem ser classificados em dois maiores grupos: químico ou físico. Entretanto, o melhor método de descontaminação de superfícies de implantes está ainda indeterminado. O objetivo desse estudo é analisar a efetividade da descontaminação de implantes com superfície de titânio por agentes condicionantes químicos e terapia fotodinâmica, por Microscopia Eletrônica de Varredura (MEV) e analisar a adesão e proliferação de células osteoblásticas previamente com superfícies descontaminadas. Implantes disponíveis comercialmente de diferentes marcas: Biomet 3i® (Nanotite NT; Osseotite - OT), Straumann® (SLActive SLA) e Neodent® (Acqua Drive CM ACQ; Neoporos Drive CM CM) foram adquiridos no mercado e analisados em imagens de MEV em 3 diferentes áreas (n=1/grupo) para determinar o parâmetro de rugosidade da superfície e a propriedade de molhabilidade. Depois disso, a superfície dos implantes dentários foi inoculada com cepa de Aggregatibacter actinomycetemcomitans (A.a.) por 4 dias e preparada para análise da MEV afim de determinar a área de porcentagem da contaminação em um software de análise de imagem. Amostras foram então descontaminadas por dois diferentes tratamentos químicos (ácido citrico 10% e ácido etilenodiamino tetraacético- EDTA 24%) e terapia fotodinâmica (azul de metileno associado com LASER), ambos em 3 minutos com tempo de aplicação. No grupo controle, os implantes foram descontaminados com clorexidina 0.12% por 3 minutos. A área de descontaminação foi determinada no software Image J para análise das imagens de MEV. Depois da descontaminação, a adesão e proliferação da linhagem de células de osteosarcoma osteoblástica humana (Saos-2) em superfícies não contaminadas de implantes estéreis (controle; n: 1/período) e implantes descontaminados (n: 3/período/grupo) foram investigados. Células da Saos-2 [5x104] foram cultivadas sobre as superficies dos implantes e incubadas por 24 horas (ensaio de adesão) e 72 horas (ensaio de proliferação) e determinadas em imagens de MEV. Não foram encontradas diferenças significantes entre os implantes em relação a parâmetros de rugosidade, com exceção para Rv (SLA: 19.57±4.01 vs. OT: 8.36±7.91; p=0.0031). Houve variação na composição química dos implantes de acordo com o tratamento de superfície, com todos os grupos mostrando prevalência do Titânio. Houve maior ângulo de contato (análise de molhabilidade) para NT (hidrofóbico) e menor para ACQ (altamente hidrofílico; p<0.0001). Nanotite/Biomet 3i® mostrou porcentagem significativamente maior de área contaminada por bactérias (68.19% ± 8.63%; p=0.050; Kruskal Wallis/Dunn) que ACQ (57.32% ± 5.38%). Osseotite/Biomet 3i® resultou em significativa menor área contaminada remanescente (50.89% ± 9.12%) depois dos tratamentos de descontaminação. Foi observada maior adesão e proliferação de células Saos-2 em SLA após 24 (p= 0.0006; ANOVA/Tukey) e 72 horas (<0.001; ANOVA/Tukey). Os grupos descontaminados mostraram número significativamente menor de células aderidas às superfícies nos dois períodos de tempo comparativamente aos controles não contaminados (p < 0.005; ANOVA post hoc Sidak). Em relação aos métodos de descontaminação, não foram observadas diferenças no número de células aderidas aos implantes tratados por terapia fotodinâmica e agentes químicos comparados com clorexidina em 24 horas, mas os primeiros mostraram maior número de células aderidas depois de 72 horas. Esses achados sugeriram que as características de superfície influenciaram a contaminação bacteriana e a descontaminação de superfície; nenhum método de descontaminação é capaz de remover completamente a contaminação bacteriana, dificultando a adesão e proliferação celular. Esses achados poderiam explicar a variação de resultados clínicos nos métodos de descontaminação e obtenção de reosseointegração.
284

Análise do comportamento biomecânico por meio de elementos finitos, de próteses parciais fixas, apoiadas sobre diferentes conexões entre dente-implante / Fit evaluation on prefabricated abutments and transmitted stress to implants by I beam superstructures as a function of implants number

Lencioni, Karina Albino 03 July 2015 (has links)
Limitações anatômicas, falhas na osseointegração, necessidade de esplintagem de dentes naturais com comprometimento periodontal podem levar a união dente-implante. Alguns autores relatam que a união com conexão da prótese semi-rígida pode causar a intrusão do dente natural, por esse motivo o uso de conexão da prótese em monobloco vem causando maior sucesso. Com isso o objetivo do trabalho é analisar a distribuição de tensão pelo método dos elementos finitos, em prótese sobre conexão dente-implante alterando o tipo de conexão da prótese, rígida e semi-rígida, e o tipo de conexão do implante, cone morse ou hexágono externo, em regiões de ligamento periodontal, osso periimplantar e conjunto prótese e implante. Para a realização do trabalho foi realizado o escaneamento dos dentes 45 e 46, através de um microtomógrafo (SkyScan, Kontich, Bélgica), as imagens em 3D dos implantes e componentes protéticos foram cedidas pela empresa Neodent (Curitiba, PR, Brasil). Nesse trabalho foram desenvolvidos quatro modelos tridimensionais todos eles representavam um hemiarcada mandibular direita com presença do dente 45 e ausência do dente 46 e 47, foram feitos modelos com implante com conexão hexagonal externa e prótese com conexão rígida ou semi-rígida, e modelos com implantes cone morse com prótese com conexão rígida ou semi-rígida. As modelagens foram realizadas no programa Rhinoceros 3D (Robert McNeel& Associates, EULA, EUA) o programa utilizado para análise dos elementos finitos foi o ABAQUS FEA (Simulia, Providence, RI, EUA).Os resultados mostraram que modelos com conexão do implante em hexágono externo geraram uma tensão de tração na distal do ligamento periodontal com presença de tensão de compressão da região apical do ligamento periodontal, sugerindo uma possível rotação do elemento dentário com posterior intrusão, independentemente do tipo de conexão protética. Já em modelos com implantes cone morse observamos uma maior distribuição de tensão no ligamento sugerindo até mesmo uma anulação da forças de tração, também independentemente do tipo de conexão da prótese. Foi observado também que próteses com implantes cone morse sofreram maior distribuição de tensão, que próteses com implantes hexágono externo, porém foi observado maior concentração de tensão na região de união pilar/implante nos dois tipos de implantes usados, não dependendo do tipo de conexão da prótese. Outro resultado observado foi um maior acúmulo de tensão no osso cortical que no osso medular, e também maior tensão no osso cortical em modelos com implante cone morse que em modelos com implante hexagonal externo, para os dois tipos de conexão da prótese. Com isso, concluímos que independentemente do tipo de conexão da prótese, o uso de implantes cone morse na união dente-implante gerou melhores resultados que o uso de implantes hexágono externo. / Anatomical limitations, failures in osseointegration, need for splinting of natural teeth with periodontal disease can lead to tooth-implant union. Some authors report that the union with the semi-rigid prosthesis connection can cause the intrusion of the natural tooth, therefore the use of the prosthesis connection monobloc is causing greater success. Thus the objective of this study is to analyze the stress distribution by finite element method, in denture on implant-tooth connection by changing the type of prosthesis connection, rigid and semi-rigid, and the type of implant connection, morse taper or external hexagon in areas of periodontal ligament, peri-implant bone and joint prosthesis and implant. To carry out the work was carried out scanning of teeth 45 and 46, through a microtomography (SkyScan, Kontich, Belgium), the 3D images of prosthetic implants and components were provided by Neodent company (Curitiba, Brazil). In this work we developed four-dimensional models they all represented a mandibular right hemi-arch with presence and absence of the tooth 45 of the tooth 46 and 47 models were made with implants with external hex connection and prosthesis with rigid or semi-rigid connection, and models with implants morse taper with prosthesis with rigid or semi-rigid connection. The modeling was performed in Rhinoceros 3D program (Robert McNeel & Associates EULA, USA) program used for finite element analysis was ABAQUS FEA (SIMULIA, Providence, RI, USA) .The results showed that implant connection with models in hexagon generated a distal external tensile stress in the periodontal ligament with presence of the apical region compressive stress of the periodontal ligament, suggesting a possible rotation of the tooth with subsequent intrusion, regardless of the type of prosthetic connection. Already in models with morse taper implants found a higher voltage distribution ligament even suggesting a reversal of traction, also regardless of the type of prosthesis connection. It was also observed that prostheses with morse taper implants suffered greater stress distribution, which aids with external hex implants, but there was a higher concentration of stress in the joining region pillar / implant in the two types of implants used, not depending on the type of connection prosthesis. Another result was observed a higher voltage accumulation in the cortical bone in the cancellous bone, and also higher voltage on cortical bone models in morse taper implant external hexagon implant models for the two types of prosthesis connection. Thus, we conclude that regardless of the type of prosthesis connection, using morse taper implants in implant-tooth union gave better results than the use of external hex implants.
285

Validação de uma máquina de testes de flexão rotacional e seus efeitos em implantes de hexágono externo e interno / Validation of a rotating bending machine and its effects on external and internal hexagon implants

Oliveira Neto, Luiz Alves de 24 April 2013 (has links)
O sucesso do tratamento com implantes dentários depende do conhecimento teórico-prático do profissional, condições biológicas do paciente, e das propriedades mecânicas dos seus componentes. Dois testes de fadiga podem avaliar as propriedades mecânicas destes materiais: ensaios monotônicos unidirecionais e testes de flexão rotacional. A vantagem do dispositivo de flexão rotacional é o ensaio mais rápido que fornece dados relevantes e uma previsão mais realista da longevidade clínica. Oliveira-Neto (2011) avaliou o dispositivo de flexão rotacional desenvolvido por Ferreira (2010), e mostrou que componentes do dispositivo necessitavam ser revistos para assegurar melhor fixação do implante, controle de temperatura, frequência e permitir modificação do momento de força aplicado aos espécimes. O objetivo deste trabalho foi confeccionar e avaliar novos componentes para o dispositivo de flexão rotacional de Ferreira (2010) e avaliar seus efeitos em sistemas de implante de hexágono externo e interno. Os grupos testados foram: Aimplantes Hexagono Externo (HE) com munhão (UCLA); B- implantes HE com Pilar Cônico; C- implantes Hexagono Interno (HI) com munhão (UCLA); D- implantes HI com Pilar Cônico. O novo método consistiu em modificações no: porta implante, porta rolamento, centralizador do implante, material de fixação (resina acrílica). As amostras foram submetidas a ciclagem em torno do seu eixo longitudinal enquanto uma extremidade estava fixada em um mandril à 45o e a outra extremidade recebia a carga. O objetivo foi determinar o nível de carga em que 50% dos espécimes sobreviveram e 50% fraturaram antes de 106 ciclos girando a 16Hz. Assim, a resistência a fadiga (F50) foi determinada através da técnica staircase analysis. Após a ciclagem, os componentes que não apresentaram falhas tiveram o destorque de remoção mensurado eletronicamente, e todas as amostras foram analisadas através de microscópio eletrônico de varredura, radiografia e fotografia digital. Os resultados mostraram que os grupos UCLA têm maior resistência à fadiga. O sistema de HI-UCLA mostrou um desempenho mais estável, com uma resistência igual ao HE. Os grupos com Pilar Cônico apresentaram falhas clinicamente melhor, permitindo a substituição de componentes protéticos. Os danos mais graves ocorreram em ambos os grupos HE, com danos aos implantes. O método de desinclusão do implante da resina precisa ser revisto visando a obtenção de imagens sem artefatos. O dispositivo de Ferreira (2010) associado às modificações propostas por Oliveira-Neto permitiu a execução do ensaio de flexão rotativa em sistema de implantes com variadas configurações, produzindo resultados clinicamente relevantes. / Implant success depends on professional ability, patient biological conditions and also mechanical properties. Two fatigue tests can study implant mechanical properties: unidirectional bend-release fatigue testing and rotational fatigue testing. Advantages of rotational bending devices include faster tests that can generate relevant data and provide more realistic prediction of clinical performance. Oliveira- Neto (2011) evaluated a rotational bending device developed by Ferreira (2010), and showed its components need to be revised to ensure better implant fixation, temperature control, frequency and also enable to increase force moment. The aim of this study was fabricate and evaluate new components to Ferreiras device and it evaluate it effects in external and internal hexagon implant systems.Following groups were tested: A-external hex (EH) implants with UCLA abutment, B- EH implants with Conical Abutment, C- internal hex (HI) implants with UCLA abutment, D- IH implants with Conical Abutment. The new methodology consisted in changes on implant holder, bearing case, implant centralizer and bone material simulator (acrylic resin). Samples were spun around their long axes while being clamped into a 45o revolving collet on one end and loaded normal to their long axis on the other end. The aim was to determine the load level at which 50% of the specimens survived- and 50% fractured before 106 cycles at 16Hz. Fatigue resistance (F50) were determined using the staircase procedure. After cycling, torque of survival components were measured electronically, and all samples were analyzed by scanning electron microscopy, x-ray and digital photography. Results showed that UCLA groups have higher fatigue resistence. The IH-UCLA system showed more stable performance, with equal resistance to EH. Conical Abutment groups failure clinically better, allowing replacement of prosthetic components. The most severe damage occurred in both EH groups, with implant damages. Ferreiras device with Oliveira-Neto changes enabled to perform a rotating bending test on implant system in numerous configurations, producing clinically relevant results.
286

Análise retrospectiva de 129 implantes osseointegráveis de ancoragem zigomática utilizados na reabilitação de maxilas severamente reabsorvidas em protocolo de dois estágios em um período de 7 anos / Retrospective analysis of 129 consecutive zygomatic implants applied for rehabilitation of severely resorbed maxilla in a double-stage protocol in a period of 7 years

Araújo, Rafael Tajra Evangelista 21 January 2016 (has links)
Este estudo tem como objetivo apresentar uma análise retrospectiva de dados contidos em prontuários de atendimento, sobre a evolução clínica de 129 implantes zigomáticos colocados no seio maxilar de 37 pacientes com maxila desdentada severamente reabsorvida (total ou parcialmente), os quais foram reabilitados através da instalação de implantes zigomáticos pela equipe de Cirurgia e Traumatologia Buco-Maxilo-Facial da Faculdade de Odontologia de Ribeirão Preto (FROP-USP), durante o período março/2007 à novembro/2014. Todos os pacientes incluídos no estudo foram tratados usando o mesmo protocolo cirúrgico, técnica ´´sinus slot´´ modificado por Stella. A análise foi direcionada a registro de dados relativos as seguintes variáveis: gênero, idade, raça, história médica, etiologia, vícios, grau de atrofia óssea, tipo e tamanho dos implantes zigomáticos, número de implantes colocados, reabilitação protética, a taxa de sobrevivência e de sucesso dos implantes, além das complicações. Os indivíduos foram acompanhados por meio de exames clínicos e de tomográficos padronizados. O critério de inclusão dos prontuários na amostra foram de pacientes submetidos a esse tipo de tratamento, com preenchimento completo de informações e de possuírem o Termo de Consentimento Livre e Esclarecido. Os dados coletados por um único examinador foram transportados para uma planilha eletrônica utilizando o programa Microsoft Excel, sendo realizada neste momento uma análise descritiva dos resultados. Trinta e sete pacientes consecutivos (25 mulheres, 12 homens; média de idade de 55,64 anos [variação: 40-77 anos]) foram tratados. Todos estavam em necessidade de reabilitação bucal e tinham atrofia maxilar severa com indicação para a colocação de implantes zigomáticos. Cento e vinte e nove implantes zigomáticos foram colocados nesses 37 pacientes. Dois dos 129 implantes falharam, resultando em uma taxa de sucesso de 98,44%, com esses dados de acompanhamento. Sinusite do seio maxilar foi a ocorrência mais comum (21,62%) entre as complicações encontradas. No entanto, entre os implantes que falharam, nenhum foi relacionado com sinusite ou fumo. Concluímos que tratamento com implantes zigomáticos representa uma opção previsível para reabilitação da maxila atrófica desdentada. No entanto, mais estudos são necessários para se relacionar diretamente esses implantes com a sinusite, que apresenta uma elevada prevalência nestes casos. / This study aims to present a retrospective analysis of data contained in patient records on the clinical course of 129 zygomatic implants placed in the maxillary sinus of 37 patients with severely resorbed edentulous maxilla (fully or partially), which were rehabilitated by installing of zygomatic implants by staff of Surgery and Traumatology Oral and Maxillofacial Ribeirão Preto Dental School (FROP-USP), during the period from March/2007 to November/2014. All patients included in the study were treated using the same surgical protocol, \'\'sinus slot\'\' modified by Stella technique. The analysis was aimed at data record the following variables: gender, age, race, medical history, etiology, addictions, degree of bone atrophy, type and size of zygomatic implants, number of placed implants, prosthetic rehabilitation, the survival rate and success of the implant, in addition to complications. The subjects were followed through clinical and standardized CT. The criterion for inclusion of the records in the sample were patients undergoing this type of treatment, with complete filling of information and possess the Informed Consent and Informed. The data collected by a single examiner were transported to a spreadsheet using Microsoft Excel program, being carried out at present a descriptive analysis of the results. Thirty-seven consecutive patients (25 women, 12 men; mean age of 55.64 years [range, 40-77 years]) were treated. All were in need of oral rehabilitation and had severe jaw atrophy indicated for the placement of zygomatic implants. One hundred and twenty-nine zygomatic implants were placed in these 37 patients. Two of the 129 implants fail, resulting in a success rate of 98.44%, with these tracking data. Maxillary sinus sinusitis was the most common event (21.62%) among the complications found. However, between implants that have failed, none has been associated with sinusitis or smoke. We conclude that treatment with zygomatic implants is a predictable option for rehabilitation of edentulous atrophic maxilla. However, more studies are needed to relate directly with these implants sinusitis, which has a high prevalence in these cases.
287

Avaliação do índice de sucesso de osseointegração em reabilitações tipo protocolo : análise retrospectiva em Cursos de Especialização em Implantodontia /

Monteiro, Ricardo Luís Prado. January 2018 (has links)
Orientador: Fernando Vagner Raldi / Banca: Rodrigo Dias Nascimento / Banca: Fábio da Silva Matuda / Resumo: O objetivo deste trabalho foi avaliar o índice de sucesso de Osseointegração por meio de uma revisão retrospectiva, dos prontuários de pacientes que receberam tratamento cirúrgico para a colocação de implantes em reabilitações totais do tipo protocolos maxilares e mandibulares, com carga tardia, realizados em cursos de pós-graduação em Implantodontia no Sindicato de Santo André - SP, ABO Regional de Barra Mansa - RJ e ABO Regional de Volta Redonda - RJ, no período de 2007 a 2013. Foram avaliados 2.208 implantes (Implacil®- São Paulo, Brasil), instalados em 398 pacientes (231 mulheres e 167 homens), com 1.323 implantes mandibulares e 885 implantes maxilares, com idade média de 59.2 anos, analisando: gênero, arcadas, tipo de implante, diâmetro e insucessos, no período de Osseointegração. Os resultados mostraram índice de insucesso em 19 mulheres (8%) e 11 homens (6,5%) com 36 implantes perdidos (1,7%), divididos em 18 perdas mandibulares (1,4%) e 18 perdas maxilares (2,1%). Com base na literatura, podemos concluir que o índice de sucesso de 98,3% obtido no estudo em cursos de especialização em implantodontia por nós ministrados foi satisfatório / Abstract : The objective of this study was to evaluate the success rate of Osseointegration by means of a retrospective review of the medical records of patients who received surgical treatment for the placement of implants in maxillary and mandibular late loading mandibular restorations performed in courses of post-graduation in Implant Dentistry at the São André Union - SP, ABO Regional of Barra Mansa - RJ and ABO Regional of Volta Redonda - RJ, from 2007 to 2013. Two hundred and twenty implants (Implacil®-São Paulo, Brazil) were evaluated, (231 women and 167 men), with 1,323 mandibular implants and 885 maxillary implants, with a mean age of 59.2 years, analyzing: gender, arches, type of implant, diameter and failures in the period of Osseointegration. The results showed failure rates in 19 women (8%) and 11 men (6.5%) with 36 implants lost (1.7%), divided into 18 mandibular losses (1.4%) and 18 maxillary losses (2,1%). Based on the literature, we can conclude that the success rate of 98.3% obtained in the study in specialization courses in implantology given by us was satisfactory / Mestre
288

Efeito da temperatura de ataque químico na superfície da liga ti6al4v usada em aplicações biomédicas /

Alberti, Charles Jourdan. January 2018 (has links)
Orientador: Adriano Gonçalves dos Reis / Coorientador: Eduardo Saito / Banca: Rodrigo Máximo de Araújo / Banca: João Paulo Barros Machado / Resumo: A modificação da superfície dos implantes é alvo de inúmeros estudos com o intuito de desenvolver alterações microestruturais no titânio e suas ligas que possam acelerar o processo de osseointegração. O futuro da implantodontia está atualmente vinculado a estas futuras descobertas. O titânio e suas ligas são amplamente utilizadas em aplicações biomédicas devido às suas propriedades de biocompatibilidade e mecânicas. Assim, o objetivo deste trabalho é avaliar o efeito nas propriedades físico-químicas de superfície da liga de Ti6Al4V após o ataque com solução piranha nas temperaturas de 25 °C, 40 °C e 60 °C num tempo constante de 30 min. Para caracterização da superfície foram utilizadas as técnicas de microscopia eletrônica de varredura com espectroscopia de energia dispersiva de raios X, perfilometria óptica, difração de raios X e molhabilidade. Além disso foram realizados ensaios de corrosão por polarização potenciodinâmica e espectroscopia de impedância eletroquímica. Os resultados demonstraram que é possível alterar a textura, a rugosidade da superfície e a resistência à corrosão da liga com a variação da temperatura de ataque químico. O tratamento de superfície proposto não alterou a molhabilidade, que se manteve hidrofílica, nem a química da superfície, que se manteve formada principalmente por TiO2 amorfo. A rugosidade e a área da superfície aumentaram exponencialmente com o aumento da temperatura, que pode estar relacionado com o aumento da cinética de reação. Pôde-se ... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The surface's modification of the implants is the subject of numerous studies with the intention of developing microstructural changes in titanium and its alloys that can accelerate the osseointegration process. The future of implantology is currently linked to these future discoveries. Titanium and its alloys are widely used in biomedical applications because of their biocompatibility and mechanical properties. Thus, the objective of this work is to evaluate the effect on the surface physicochemical properties of the Ti6Al4V alloy after the piranha solution attack at temperatures of 25 °C, 40 °C and 60 °C at a constant time of 30 min. To characterize the surface were used the techniques of scanning electron microscopy with dispersive energy X-ray spectroscopy, optical profilometry, X-ray diffraction and wettability. In addition, corrosion tests were carried out by potentiodynamic polarization and electrochemical impedance spectroscopy. The results showed that it is possible to change the texture, surface roughness and corrosion resistance of the alloy with the variation of the etching temperature. The proposed surface treatment did not alter the wettability, which remained hydrophilic, nor the surface chemistry, which remained mainly amorphous TiO2. Roughness and surface area increased exponentially with increasing temperature, which may be related to the increase in reaction kinetics. It was possible to obtain a sponge-like threedimensional texture with formation of nano an... (Complete abstract click electronic access below) / Mestre
289

Desenvolvimento de metodologia computacional para avaliação do comportamento do tecido ósseo ao redor de diferentes superfícies de implantes em humanos /

Gouveia, Wellington da Rocha. January 2018 (has links)
Orientador: Antônio Carlos Guastaldi / Banca: André de Souza Tarallo / Banca: Luiz Ricardo Menani / Banca: Vanderlei Salvador Bagnato / Banca: Jonas de Carvalho / Resumo: A reabilitação oral utilizando-se implantes dentários está dentre os procedimentos necessários para a manutenção da qualidade de vida do cidadão. No Brasil, são instalados aproximadamente 1 milhão de implantes por ano. Atualmente o procedimento para a instalação de implantes e, subsequentemente, a reabilitação com próteses sobre implantes tem seus custos determinado com os materiais utilizados e pelo tempo que o profissional dispende neste tipo de procedimento. As metodologias modernas, não acompanham a demanda crescente por este tipo de procedimento. É importante salientar que devido ao grande avanço nos equipamentos utilizados para obtenção de radiografias digitais odontológicas, surge a necessidade do desenvolvimento de novas metodologias computacionais para o auxílio no diagnóstico. Essa tese apresenta o início do desenvolvimento de novas metodologias computacionais para processamento e análise de radiografias digitais odontológicas, metodologias essas de suma importância na área odontológica, pois devido ao envelhecimento da população e cada vez mais a necessidade de reabilitação oral com implantes dentários, demonstra que é de suma importância o desenvolvimento de novas metodologias para auxiliar os profissionais de odontologia em seus diagnósticos. / Abstract: Oral rehabilitation using dental implants is among the procedures necessary to maintain the quality of life of the citizen. In Brazil, approximately 1 million implants are installed per year. Currently, the procedure for the implant installation and, subsequently, the rehabilitation with implants has its costs determined with the materials used and the time that the professional spends on this type of procedure. Modern methodologies do not accompany the increasing demand for this type of procedure. It is important to note that due to the great advance in the equipment used to obtain dental digital radiographs, the need arises for the development of new computational methodologies to aid in diagnosis. This thesis presents the beginning of the development of new computational methodologies for the processing and analysis of dental digital radiographs, which are extremely important methodologies in the dental area, since due to the aging of the population and increasingly the need for oral rehabilitation with dental implants, the development of new methodologies to assist dentistry professionals in their diagnosis is of paramount importance. / Doutor
290

Pode a seleção da técnica ser superior ao material escolhido para a união de transferentes? / Can the selection of the technique be superior to the material selected for the splint of transferents?

Mariotto, Guilherme de Aguiar 27 March 2018 (has links)
Submitted by Edineia Teixeira (edineia.teixeira@unioeste.br) on 2019-03-12T21:59:27Z No. of bitstreams: 2 Guilherme_Mariotto_2018.pdf: 1557188 bytes, checksum: a9d67c335a6fbbe03d061239156c3baf (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Made available in DSpace on 2019-03-12T21:59:27Z (GMT). No. of bitstreams: 2 Guilherme_Mariotto_2018.pdf: 1557188 bytes, checksum: a9d67c335a6fbbe03d061239156c3baf (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Previous issue date: 2018-03-27 / STATEMANT OF PROBLEM: The splint transfer technique in implant impression can result in misfit on prosthetic structures. PURPOSE: To evaluate the linear dimensional change of polymerization from 3 materials and 2 techniques of splint transfer technique for implant prostheses used in the open tray technique. MATERIAL AND METHODS: Two implants were installed in a nylon mastermodel whith the shape of a upperjaw, over this two implants, miruscone were tapered. Open tray transfer impression coppings were coupled in to the miruscone, and a silicone guide was made standardizing the unions between the transfers. The samples were divided in six groups (n=20): autopolymerizing acrylic resin Pattern Resin (PA) and Durallay (DU), and bis-acrylic resin Protemp4 (BI), with single step and sectioning and bonding segments techniques (PAC, DUC, BIC). The values of linear dimensional change between these transfers were measured in a profile projector (VB300; Starret) coupled to the Quadra Check apparatus, with a measurement capacity of 0.001 mm, performed by a calibrated single operator. Data were submitted to factorial ANOVA, two-way: Materials and technique (p <0.01) RESULTS: Statistically significant results were found in all comparisons. The PA resin presented the smallest values (μm) of linear dimensional change, both in the single-step technique and in the section and conding, in the following order: BI 255.73(+3.81), DU 173.75(+2.30), PA 95.97(+3.20), BIC 23.82(+1.71), DUC 20.85(+2.53), PAC 13.27(+2.09). The single-step technique obtained worse results regardless of the material. CONCLUSIONS: The sectioning and bonding technique reduced the dimensional change of the samples in all materials, and the Pattern Resin LS presented the lowest contraction, followed by Durallay and Protemp4. CLINICAL IMPLICATIONS: For the transfer splintage in implant prothesis the choice of technique seems to be more importante than the selection of the material to get fidelity of the models / DECLARAÇÃO DO PROBLEMA: A técnica de união entre os transferentes de moldagem para próteses sobre implantes pode resultar em desadaptações nas infraestruturas protéticas. OBJETIVOS: Avaliar a alteração dimensional linear de polimerização de 3 materiais e 2 técnicas de união de transferentes de moldagem para próteses sobre implantes utilizados na técnica da moldeira aberta. MATERIAL E MÉTODOS: Foi confeccionada uma matriz em forma de maxila em nylon, instalados dois implantes osseointegráveis e, sobre esses dois, minipilares cônicos retos. Transferentes de moldagem de moldeira aberta foram acoplados aos minipilares, e uma guia de silicone foi confeccionada padronizando as uniões entre transferentes. As amostras foram divididas em seis grupos (n=20): resinas acrílicas quimicoativadas Pattern Resin (PA) e Durallay (DU), e resina bisacrílica Protemp4 (BI), com as técnicas passo único e secção e união dos segmentos (PAC, DUC, BIC). Os valores de alteração dimensional linear ocorridos entre esses transferentes foram mensurados em projetor de perfil (VB300; Starret) acoplado ao aparelho Quadra Check, com capacidade de mensuração de 0.001 mm, realizado por único operador calibrado. Os dados foram submetidos ao teste de ANOVA fatorial, two-way: Materiais e técnica (p<0,01). RESULTADOS: Foram encontrados resultados estatisticamente significantes em todas as comparações. A resina PA apresentou os menores valores (μm) de alteração dimensional linear, tanto na técnica de passo único, quanto na técnica de secção e união, na seguinte ordem: BI 255.73(+3.81), DU 173.75(+2.30), PA 95.97(+3.20), BIC 23.82(+1.71), DUC 20.85(+2.53), PAC 13.27(+2.09). A técnica de passo único obteve piores resultados independente do material. CONCLUSÕES: A técnica de secção e união reduziu a alteração dimensional das amostras em todos os materiais, e a resina Pattern Resin LS apresentou a menor contração, seguida pela Durallay e Protemp4. IMPLICAÇÕES CLÍNICAS: Para a união de transferentes em próteses sobre implantes a escolha da técnica de união parece ser mais importante do que a seleção do material para a obtenção de maior fidelidade dos modelos.

Page generated in 0.072 seconds