• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 306
  • 96
  • 34
  • 21
  • 15
  • 9
  • 8
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 1
  • Tagged with
  • 561
  • 561
  • 314
  • 292
  • 117
  • 83
  • 76
  • 74
  • 67
  • 66
  • 60
  • 59
  • 58
  • 58
  • 51
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
311

Painéis de vedação de concreto moldados in loco: avaliação de desempenho térmico e desenvolvimento de concretos / Cast-in-place monolithic panels of concrete: evaluation of thermal performance and development of concrete

Helenice Maria Sacht 28 August 2008 (has links)
A carência habitacional é atualmente um dos maiores desafios urbanos para as políticas públicas das cidades brasileiras e deve impulsionar a busca de soluções tecnológicas para o desenvolvimento de habitações com baixo custo e desempenho satisfatório. Nesse contexto se insere o sistema construtivo de painéis monolíticos de concreto moldados in loco. Nesta pesquisa apresenta-se uma proposta de desenvolvimento de concretos destinados ao sistema construtivo de painéis monolíticos moldados in loco, tendo como referencial, além dos requisitos técnicos de trabalhabilidade, resistência mecânica e durabilidade, a influência dos painéis no desempenho térmico das habitações. Com isso, o desenvolvimento dos concretos assim como a definição de espessura do painel de vedação foi realizado, considerando as particularidades das oito diferentes zonas bioclimáticas brasileiras e as tipologias construtivas adotadas pela Companhia de Desenvolvimento Habitacional e Urbano (CDHU) e Caixa Econômica Federal (CEF). Por meio de simulações computacionais do desempenho térmico de edificações térreas (com laje plana, com laje inclinada e sem laje) e multipavimentos (cobertura e segundo pavimento), avaliaram-se as espessuras dos painéis (8, 10 e 12 cm) e as massas específicas dos concretos (1600, 1800, 2000, 2200 e 2400 kg/m³) adequadas em relação às características climáticas das localidades analisadas, utilizando como parâmetro a norma NBR 15575 Edifícios habitacionais de até cinco pavimentos - Desempenho, da Associação Brasileira de Normas Técnicas. A partir da avaliação do desempenho térmico das tipologias selecionadas, dentre os concretos e as espessuras de painéis analisadas, observou-se que as tipologias com painéis de concreto com massa específica de 2400 kg/m³ e com espessura de 12 cm foram as que apresentaram os melhores resultados para as oito regiões bioclimáticas analisadas. / Nowadays, the lack of housing has been one of the biggest urban challenges to the Brazilian public policies and should impel the search for technological solutions by the development of housings with low-cost and satisfactory performance. In this context is the constructive system of cast-in-place monolithic panels of concrete. This dissertation presents a proposal for the development of concretes destined to the system having the technical requirements of workability, mechanical resistance and durability, and the influence of the panels peculiarities on the thermal performance of the housings as reference. Herewith, the development of concretes as well as the panels thicknesses definition has been realized, considering the particularities of the eight different Brazilian climate zones, and the constructive typologies used by the Companhia de Desenvolvimento Habitacional e Urbano do Estado de São Paulo (CDHU) and Caixa Econômica Federal (CEF). By means of computational simulations of thermal performance of one-storey (with plane and inclined slabs, and without slab) and multi-storey (last and second floors) constructive typologies, the suitable panels thicknesses (8, 10 and 12 cm) and concretes densities (1600, 1800, 2000, 2200 and 2400 kg/m³) in relation to the climatic characteristics of the analyzed places were determined, having the standard NBR 15575 Residential buildings up to five storied Performace of the Associação Brasileira de Normas Técnicas as parameter. Starting from the evaluation of the thermal performance of the selected typologies, among concretes and panels thickness analyzed, the use of concretes panels with densities of 2400 kg/m³ and thicknesses of 12 cm has been presented better results for the eight Brazilian climate zones.
312

Desempenho térmico de habitações do PMCMV em paredes de concreto : estudo de caso em São Carlos-SP e diretrizes de projeto para a Zona Bioclimática 4 / Thermal sensation in low-income brazilian houses built in concrete walls

Simone Mesquita Alvares 13 June 2018 (has links)
O atual programa de contenção do déficit habitacional brasileiro, Minha Casa Minha Vida, criado em 2009, apesar de numericamente significativo, apresenta uma série de complicações e inadequações. Um importante exemplo é a inadequação das construções à Zona Bioclimática na qual o projeto é construído. Diante desse fato, o conforto térmico do usuário deixa a desejar pois os ambientes são desconfortáveis e nada sustentáveis do ponto de vista ambiental. Neste contexto, o trabalho teve como objetivo avaliar o desempenho térmico de habitações de interesse social do PMCMV na Zona Bioclimática 4 construídas com paredes de concreto armado moldadas no local, técnica de rápida execução que vem sendo utilizada em larga escala no país; complementarmente, foi analisada a percepção do usuário frente às condições de conforto térmico em um desses residenciais. A avaliação do desempenho térmico das habitações foi feita com base nos regulamentos nacionais NBR 15220 e NBR 15575 em seus procedimentos simplificados; para avaliar a ventilação, via método de visualização de escoamento (mesa dágua) e a insolação, via simulação computacional de horas de sombreamento com auxílio de cartas solares; para a avaliação da percepção do usuário frente ao conforto térmico, foram feitas pesquisas de campo em um dos empreendimentos de habitações sociais na zona em estudo tendo como base os questionários ASHRAE 55 juntamente com coleta de dados climáticos de temperatura e umidade relativa e com levantamento de modificações projetuais. A partir dos dados coletados, pôde-se confirmar objetivamente a inadequação aos limites mínimos estabelecidos pelas normas de desempenho térmico nos parâmetros de vedação vertical e cobertura. Em entrevista com os moradores, as casas foram consideradas desconfortáveis termicamente no inverno e verão. A partir do diagnóstico das alterações nos projetos, nota-se que a maior parte das casas sofrem alterações para maior adequação à vida dos moradores, essas que se tornam responsáveis pelo desconforto térmico. Fica evidente a necessidade do aumento da inércia térmica do sistema construtivo, para futuras casas construídas com o referido sistema além da necessidade de um plano de expansão da moradia que oriente o morador a fazer modificações que não prejudiquem o desempenho térmico do edifício e o conforto térmico dos habitantes. / The current Brazilian low-income housing program, named Minha Casa Minha Vida, was created in 2009 by the Brazilian government and despite being numerically significant, it has many significant issues that affect its quality. One important example is the used construction methods that do not take into account the climate or the bioclimatic zones where the houses are located resulting in energy efficiency, environmental and thermal confirm issues. This work is developed in this context and aims to evaluate the objective and subjective thermal performance of the houses built in the Zone 4 with reinforced concrete walls molded in place, which is a widespread construction technique within the studied program. Thermal performance of the dwellings was analyzed in the light of the Brazilian regulation norm NBR15220 and NBR 15575. Surveys based on ASHRAE 55 norm were conducted to evaluate the user\'s thermal comfort perception and in situ measurements were taken at the studied bioclimatic zone. From the data collected, we conclude that the houses do not meet the norm limits and that they are also subjectively uncomfortable, during summer and winter. As means to increase comfort, we note that all houses dwellers modified their houses making it clear that future houses should have more thermal inertia and that, as the program expands, dwellers should be instructed to not make construction changes that might affect their thermal comfort.
313

Os primeiros estudos sobre conforto termico no Brasil : a contribuição de Paulo Sa / The researches about thermal comfort in Brazil, the research of Paulo Sa

Oliveira, Mariela Cristina Ayres de 30 October 2003 (has links)
Orientador: Lucila Chebel Labaki / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil, Arquitetura e Urbanismo / Made available in DSpace on 2018-08-04T11:09:28Z (GMT). No. of bitstreams: 1 Oliveira_MarielaCristinaAyresde_M.pdf: 6854389 bytes, checksum: b57a8ee9716fad941cfcb623a482fdf3 (MD5) Previous issue date: 2003 / Resumo: A preocupação com a avaliação de conforto no Brasil, em meados de 1930, procurava nos métodos, propostos e utilizados internacionalmente, condições de adaptá-los às variáveis brasileiras. Tem-se conhecimento do trabalho de dois pesquisadores brasileiros sobre índices de conforto térmico nessa época: Paulo Sá e Benjamim Alves Ribeiro. Estas pesquisas buscam estabelecer uma relação entre a sensação individual de conforto térmico e os índices obtidos pelos vários métodos utilizados na época, principalmente as catatemperaturas e a temperatura efetiva. O resgate e análise da pesquisa de Paulo Sá demonstram não apenas a abordagem científica e a obtenção de temperaturas de conforto térmico para a cidade do Rio de Janeiro, como também as dificuldades metodológicas e científicas existentes. Os valores encontrados pelas pesquisas de Paulo Sá e Benjamin Alves Ribeiro foram utilizados para cálculo do VME, proposto por Fanger, através do uso do software Conforto 2.02. O trabalho também apresenta a metodologia utilizada por Paulo Sá e Benjamim Alves Ribeiro, Fanger e Michael Humphreys em pesquisas realizadas em escolas ou com estudantes. Destes, apenas Fanger trabalhou com câmaras climatizadas. O ambiente escolar tem se mostrado propício a estudos de avaliação de conforto térmico, tanto pela importância do mesmo, como pela atividade desenvolvida, faixa etária e facilidade de implementação da pesquisa. Desse modo, uma descrição e comparação de metodologias relativas ao ambiente escolar são relatados neste trabalho / Abstract: The researches about thermal comfort evaluation in Brazil, in the middle of 1930, were searching for the internationally used and proposed methods, so that the conditions to adapt them to Brazilian environmental parameters could be achieved. The work of two Brazilian researchers who were researching thermal comfort indexes by that time are known: Paulo Sá and Benjamim Alves Ribeiro. In their researches they were working to establish a relationship between the individual thermal sensation and the indexes obtained by the several methods used at that time, mainly the catatemperatures and the effective temperatures. When analyzing the research of Paulo Sá, it can be shown his scientific approach and the obtaining of comfort temperatures for the city of Rio de Janeiro, as well as the existent methodological and scientific difficulties. The values found by those authors were used to the calculation of the PMV, proposed by Ole Fanger, through the use of the software Comfort 2.02. This work also presents the methodology used by Paulo Sá and Benjamim Alves Ribeiro, Fanger and Michael Humphreys in researches accomplished at schools or with students. Fanger worked with students in acclimatized cameras and the others with naturally ventilated environments. Schools are an appropriate environment to studies about thermal comfort evaluation not only due to the importance of the theme, but also for the developed activity, age group and easiness of implementation of the research. A description and comparison of different methods applied to the school environment are presented in this work / Mestrado / Edificações / Mestre em Engenharia Civil
314

AVALIAÇÃO DO CONFORTO TÉRMICO DE UM APRISCO PARA A CIDADE DE SANTA MARIA/RS / COMFORT ASSESSMENT THERMAL ONE BUILDING FOR SANTA MARIA CITY / RS

Santos, Eudes Vinícius dos 21 October 2015 (has links)
Sheep production has always played a fundamental role in society throughout history, and it has been highlighted as an important economic activity in Rio Grande do Sul, Brazil. Rio Grande do Sul presents climatic peculiarities that in some situations impose a condition of thermal discomfort in animals, generating heat stress, which is one of the main limiting factors of animal production. Seeking alternatives that provide better thermal comfort for confined animals and a consequent greater production is essential. This study was carried out with sheep and lambs confined in a fold (fenced enclosure area) at Universidade Federal de Santa Maria and aimed to evaluate the thermal comfort that the fold gives animals in a typical winter and summer day. We assessed environmental variables such as air temperature, radiant temperature, relative humidity, and air velocity. Subsequently, the Black Globe and Humidity Index (BGHI) and Thermal Comfort Index (TCI) were utilized to evaluate animal thermal comfort. Additionally, rectal temperature, respiratory rate, and skin temperature of the animals as well as thermographic images of the wool surface of the (fur) animals and fold were evaluated. Based on data gathering and calculation of the indices, it was possible to observe that the animals were in thermal discomfort for most part of the experiment. For the typical winter period, no reference values of BGHI and TCI were found; however, some animals had a rectal temperature of 35.5 ° C, which is below normal levels. The fold had thermal cushioning below 28%, imposing internal temperatures of 7.8 ° C in the animals. This temperature is out of the thermal comfort zone (TCZ), which lies between 25 and 30 ° C for newborns and between 15 and 30 ° C for adult animals, being close to 6 ° C, which is considered lower critical temperature (TCL). For the typical summer period, the building had a heat buffer below 10% and it was possible to assess comfort using BGHI and TCI. During the morning, BGHI was below 74, which represents thermal comfort values. On the other hand, the fold in the afternoon presented BGHI ranging between 74 and 79, which represents state of alert. As a conclusion, the fold studied does not provide thermal comfort for animals in most of the typical winter and summer period. As a consequence, it requires constructive improvements to ensure that animals are provided with comfort and well-being so that they reach their maximum productive and reproductive performance. / A ovinocultura exerce papel fundamental na história e na pecuária do Rio Grande do Sul e vem se destacando como importante atividade econômica no Brasil. O Rio Grande do Sul, por sua vez, apresenta peculiaridades climáticas que impõem aos animais, em algumas situações, uma condição de desconforto térmico, gerando o estresse térmico, que é um dos principais fatores limitantes da produção animal. Portanto, torna-se imprescindível a busca por alternativas de conforto térmico que proporcionem bem estar aos animais e que gerem maior potencial na sua produção, principalmente em ambientes protegidos. Pretendeu-se, com este trabalho, avaliar o conforto térmico que a edificação, denominada aprisco (instalação para ovinos) proporciona aos animais (cordeiros e borregos) confinados no laboratório de ovinocultura da Universidade Federal de Santa Maria, para um dia típico de inverno e um dia típico de verão, por meio do levantamento das variáveis ambientais, tais como temperatura do ar, temperatura radiante, umidade relativa, velocidade do ar e posterior cálculo do Índice de Temperatura de Globo Negro e Umidade (ITGU) e do Índice de Conforto Térmico (ICT), ambos índices para avaliar o conforto térmico animal. Também foram realizadas a coleta da temperatura retal, da frequência respiratória e da temperatura da epiderme dos animais, bem como o levantamento de imagens termográficas da superfície da lã (vélo) dos animais e do aprisco. Foi possível avaliar, com base nos levantamentos de dados e no cálculo dos índices, que os animais estavam em desconforto térmico na maior parte do experimento. Para o período típico de inverno, não foram encontrados valores de referência dos índices ITGU e ICT; no entanto, alguns animais apresentaram temperatura retal de 35,5°C, abaixo do normal. A edificação (aprisco) teve um amortecimento térmico abaixo de 28%, impondo aos animais, temperaturas internas de 7,8°C, isto é, fora da zona de conforto térmico (ZCT), que se encontra entre 25 e 30°C para animais recém-nascidos e entre 15 e 30°C para animais adultos, estando mais próximas de 6°C, considerada temperatura crítica inferior (TCI). Para o período típico de verão, a edificação apresentou amortecimento térmico abaixo de 10% e foi possível avaliar o conforto através dos índices, ITGU e ICT. Durante o período da manhã, o ITGU ficou abaixo de 74, o que representa valores de conforto térmico. Já no período da tarde, as instalações apresentaram ITGU compreendidos entre 74 e 79, o que significa situação de alerta. Portanto, ao fim do experimento, foi constatado que a edificação (aprisco) não proporciona conforto térmico aos animais na maior parte do período típico de inverno e verão. Por fim, entendeu-se que a edificação existente precisa de melhorias construtivas para que os animais disponham de conforto e bem estar para que atinjam seu máximo rendimento produtivo e reprodutivo.
315

Respuesta térmica de edificaciones con envolventes vegetales: cubiertas verdes y fachadas verdes / Thermal response in buildings with green covers: green roofs and green facades

Nuria Pérez Gallardo 16 March 2017 (has links)
El presente proyecto propuso un método experimental de medición de temperaturas internas con el fin de estudiar, comparar y entender la respuesta térmica frente al frío y al calor de cuatro células de ensayo denominadas Control (Sin vegetación) y tres células de ensayo con diferentes combinaciones de vegetación (cubiertas y fachadas) instaladas en una región de clima tropical. En ellas fueron medidas las temperaturas superficiales internas (TSI) y temperaturas del Bulbo Seco (TBS) mediante equipos específicos, un data logger, conectado a dos multiplicadores. Los datos fueron recogidos por un año y dentro de ese periodo fueron seleccionados los días críticos a estudiar. Varios datos climatológicos fueron considerados para abordar la influencia de las oscilaciones del tiempo meteorológico (episodios climáticos) en el ambiente interno construido, para lo cual fueron aplicados fundamentos de la Climatología Dinámica frente al comportamiento térmico de las células de ensayo. Los datos de las principales variables climáticas (radiación solar, humedad relativa y precipitación) fueron registradas en la Estación Meteorológica del CRHEA. Los resultados revelan que la célula de ensayo con vegetación en cubierta y fachadas, presenta más resistencia a las variaciones de temperaturas diarias, es decir, mejor comportamiento térmico, ya que muestra las menores amplitudes térmicas, los mayores retrasos térmicos, las menores temperaturas en días de calor extremo y las mayores en días de frío. Durante el día crítico de calor, las mayores diferencias entre las temperaturas máximas internas del aire, se presentan entre la célula construida con materiales convenciones y la célula que posee fachadas verdes y cubierta vegetal, de 2ºC y en torno a 3ºC en el caso de las temperaturas superficiales. Para el día crítico de frío, la diferencia entre ellas es de 1ºC para los valores de temperatura del aire, y de 2.2ºC para valores de temperaturas superficiales. Así, uso de vegetación en los edificios puede ser considerado una técnica capaz de mantener las condiciones internas más placenteras no solo en épocas calurosas, reduciendo la incidencia de la radiación solar directa, sino también en invierno, debido a su propiedad de aislante térmico que impide las rápidas pérdidas de calor, como ocurre en la célula sin vegetación. Los resultados obtenidos ponen de manifiesto que las hipótesis planteadas fueron alcanzadas, comprobando así, que el uso de vegetación combinado en fachadas y cubiertas contribuye a la mejora del comportamiento térmico, favoreciendo las condiciones térmicas internas en periodos de mayor o menor temperatura externa. / The present research proposed an experimental method for measuring internal temperatures of buildings, in order to study, compare, and understand the thermal response of four test cells against cold and heat, determined: control (without vegetation) and three test cells with different combinations of vegetation (on roofs and/or facades); installed in a tropical climate region. Internal surface temperatures (IST) and dry bulb temperatures (DBT) were measured using appropriate equipment, consisting of a data logger connected to two multipliers. Data were collected for one year and, during that period, the critical days that would be assessed were selected. Climatic data were considered in order to evaluate the influence of weather oscillations (climatic events) on the internal built environment, for which the principles of Dynamic Climatology were applied to understand the thermal behaviour of the test cells. The data obtained from the primary climatic variables (solar radiation, relative humidity, and precipitation) were recorded at the CRHEA. The results showed that the test cell with a green roof and green facades displayed higher resistance to changes in daily temperature, i.e., better thermal behavior, since it faced lower temperature intervals, higher thermal delays, lower temperatures on days of extreme heat, and higher temperatures on cold days. With respect to the critical heat day, the main differences between maximum internal air temperatures occurred between the cell constructed with conventional material and the cell that was built with green facades and a green roof, of 2°C in relation to the internal air temperature, and approximately 3°C with respect to surface temperatures. Regarding the critical cold day, the difference between test cells was of 1°C for air temperature values, and 2.2°C for surface temperature values. Therefore, the use of vegetation in construction can be considered a technique capable of maintaining the most pleasant indoor conditions, not only in hot climates, reducing the incidence of direct solar radiation, but also in the winter, due to thermal insulation properties that prevent the rapid loss of heat, which occurs in cells lacking vegetation. The obtained results show that the initial hypotheses were proven, thus confirming that the application of vegetation on facades and roofs contributes to the improvement of thermal performance, favoring internal thermal conditions during periods of higher or lower external temperatures.
316

Isolamento térmico com material reciclado em escamoteadores aquecidos / Thermal insulation with recycled material in heated creep

Sartor, Karina, 1983- 28 August 2018 (has links)
Orientador: Luiz Antonio Rossi / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Agrícola / Made available in DSpace on 2018-08-28T04:23:54Z (GMT). No. of bitstreams: 1 Sartor_Karina_M.pdf: 1616477 bytes, checksum: 8bc1c2182f361f23bdb743e97299dedb (MD5) Previous issue date: 2015 / Resumo: Os leitões recém-nascidos possuem baixa capacidade de reter calor corporal em razão do menor isolamento térmico pelo pouco tecido adiposo, pouca cobertura de pelos e maior superfície corporal em relação ao peso. A ausência de conforto térmico aos leitões em fase de maternidade provoca redução do peso ao desmame e susceptibilidade a doenças. A manutenção do conforto térmico para os leitões lactentes exige alta demanda energética para promover o aquecimento do escamoteador. O experimento foi conduzido na sala maternidade em granja comercial objetivando avaliar a eficiência térmica do isolamento com a placa ecológica Tetra Pak® no revestimento do escamoteador para promover o conforto térmico dos leitões e uso racional de energia elétrica. Foram mensurados os parâmetros climáticos no interior do escamoteador, temperatura superficial do piso, temperatura superficial de pele, episódios comportamentais, ganho de peso dos leitões e eficiência energética. Os resultados obtidos com o estudo demonstraram que o revestimento do escamoteador com isolante térmico manteve a temperatura de conforto térmico dos leitões lactentes. A temperatura superficial de pele e os episódios comportamentais dos leitões lactentes foram normais. O ganho de peso foi similar nos dois tratamentos. A utilização da placa Tetra Pak® como isolante térmico no revestimento do escamoteador para leitões lactentes mostra eficiência térmica e energética / Abstract: The newborn piglets exhibit low ability in retaining body heat which is associated to the lower thermal insulation offered by the thin fat layer, little hair coverage and greater body surface area to weight ratio. The absence of thermal comfort at the maternity phase causes weight reduction of piglets at weaning as well as susceptibility to diseases. Thermal comfort for suckling piglets demands high energy to promote heating creep area. The experiment was carried out in the maternity room of a commercial farm to evaluate the thermal insulation efficiency with the ecological Tetra Pak® plaque thermal efficiency to promote thermal comfort to the piglets as well as rational use of electricity. Climatic parameters were read inside the creep area, floor surface temperature, skin surface temperature, behavioral episodes, piglets weight gain and energy efficiency. The results of this study showed that the creep area of the coating insulator maintained the temperature improving thermal comfort to the suckling piglets. The skin surface temperature and the behavioral episodes of suckling piglets were noted to be normal. Weight gain was similar for both treatments. The use of Tetra Pak® plaque as thermal insulation in creep area flooring for suckling piglets showed thermal and energy efficiency / Mestrado / Construções Rurais e Ambiencia / Mestra em Engenharia
317

Avaliação de tapete de borracha reciclável em piso de escamoteadores e sua influência no desenvolvimento e bem-estar de leitões na fase de maternidade / Evaluation of recyclable rubber in creep and its influence on the development and welfare of piglets in maternity

Beatriz de Oliveira Possagnolo 26 June 2017 (has links)
Um dos grandes pilares para o sucesso da produtividade da produção de suínos é o aumento da taxa de leitões nascidos por matriz. Porém, para que esse resultado seja satisfatório, é necessário reduzir as taxas de mortalidade de leitões ao nascimento e aumentar o ganho de peso por leitegada. Nesse sentido, deve-se priorizar o bem-estar dos animais, reduzir os custos na produção e utilizar recursos favoráveis à sustentabilidade da produção. A borracha reciclável é um excelente recurso sustentável, podendo trazer benefícios para os leitões por ser um produto resistente, que absorve impacto e apresenta consistência macia, tornando o ambiente mais confortável, bom condutor térmico e antiderrapante. Esta pesquisa teve como objetivo avaliar a eficiência da cobertura do piso de escamoteadores com borracha reciclável com a utilização de dois diferentes tipos de tapete, em relação à utilização de piso convencional (piso de concreto coberto por maravalha), com o propósito de identificar a melhor adaptação dos leitões, observando o conforto térmico e consequentemente o desenvolvimento animal e aumento da produtividade. A pesquisa foi realizada no município de Mogi-Mirim/SP entre os meses de julho a agosto de 2015. Foram estabelecidos três tipos de tratamento: Tratamento 1 (T1) - piso coberto por maravalha; Tratamento 2 (T2) - piso coberto com tapete de borracha inteiriça; Tratamento 3 (T3) - piso coberto com tapete de borracha vazada, para 12 leitegadas (±50 animais/ tratamento). Os parâmetros analisados foram: comportamento e avaliação fisiológica avaliados em dias intercalados durante o experimento, em três períodos: manhã (H1 - 7:00h às 11:00h), tarde (H2 - 12:00h às 15:00h) e noite (H3 - 16:00h às 18:00h); e os índices zootécnicos e microclima das instalações avaliados diariamente. Utilizou-se o delineamento inteiramente casualizado (DIC) para as análises dos dados referentes à entalpia, ITU e comportamento; e delineamento em blocos casualiazados (DBC) referente aos dados das análises fisiológicas. As médias foram analisadas pelo teste de Tukey, a 5% de significância. A análise do microclima das instalações evidenciou estresse por frio constante, caracterizado pela entalpia abaixo de 68,40, porém dentro da faixa ideal dada pelo índice de temperatura e umidade (menor ou igual a 70). Os animais dos tratamentos com piso do escamoteador coberto por tapete de borra (vazado e inteiriço) mativeram-se por maior tempo, e expressaram uma maior quantidade de comportamentos dentro do escamoteador, quando evidencianda a escolha por um local de melhor conforto, em comparação ao tratamento convencional (maravalha). A utilização do tapete (inteiriço e vazado) influenciou de forma positiva, em melhorias na produção, ao que se refere ao índice de mortalidade por esmagamento. Este trabalho abre novas possibilidades de se avaliar a utilização de tapete de borracha reciclável na produção de suínos. Inaugura possibilidades de estudo de novos designs de tapete e de local de instalação, a fim de estabelecer um produto inovador e sustentável, tornando-o uma ferramenta rentável e eficientemente econômica na produção de suínos. / One of the great pillars for the swine production productive success is the increase in the rate of piglets by sow. However, for this result to be satisfactory it is necessary to reduce the piglet death rate at birth and increase the weight gain by litter. Hence, the animal welfare must be prioritized, the production costs reduced and favorable resources to the production sustainability used. The rubber is recyclable and it is an excellent sustainable resource that can benefit the piglets since it is a resistant material capable of absorbing impact, soft, able to make the environment more comfortable, good heat conductor and non-slip. The objective of this research is to evaluate the efficiency of covering the creep ground with recyclable rubber with the utilization of two different kinds of mats in relation to conventional ground (concrete covered by shavings), aiming to identify the best piglets adaptation taking in observation the thermal comfort, the animal development and increase in productivity. The research took place in the municipality of Mogi-Mirim/SP from July to August of 2015. Three treatments were established: Treatment 1 (T1) - ground covered by shavings; Treatment 2 (T2) - ground covered by rubber mat; Treatment 3 (T3) - ground covered by leaked rubber mat, for 12 litters (+-50 animals/treatment). The analyzed parameters were: behavior and physiological evaluation every other day during the experiment, in three periods: mornings (H1 - 7:00h to 11:00h), afternoon (H2 - 12:00h to 15:00h) and evening (H3 - 16:00h to 18:00h); and the zootechnical indices and the facilities microclimate evaluated daily. It was utilized a Completely Randomized Design (DIC) for the analyses of the enthalpy data, ITU and behavior; and Randomized-Completeblocks Design (DBC) for the physiological analysis. The averages were analysed by the Tuckey\'s test at 5% significance. The facilities microclimate analysis emphasized a constant cold stress, characterized by the enthalpy below 68,40, however, it falls in the ideal range given by the humidity and temperature index (less or equal to 70). The animals from the treatments with rubber mats maintained for a longer period of time and expressed a greater quantity inside of the creep, evidencing a choice for a place of better comfort, compared to the conventional treatment (shavings). The utilization of mats influenced in a positive way in the production when it comes to mortality by crushing. This study opens up new possibilities of evaluating the utilization of recyclable rubber in swine production. Inaugurate possibilities of studying new mat designs, placing in order to establish an innovative product, sustainable, making it a rentable tool, economically efficient in the swine production.
318

A Study to Evaluate Urban Heat Mitigation Design Strategies to Improve Pedestrian’s Thermal Perception in Existing Canyons of Extreme Hot-Arid Cities. The Case of Phoenix, Arizona

January 2020 (has links)
abstract: The rapid rate of urbanization coupled with continued population growth and anthropogenic activities has resulted in a myriad of urban climate related impacts across different cities around the world. Hot-arid cities are more vulnerable to induced urban heat effects due to the intense solar radiation during most of the year, leading to increased ambient air temperature and outdoor/indoor discomfort in Phoenix, Arizona. With the fast growth of the capital city of Arizona, the automobile-dependent planning of the city contributed negatively to the outdoor thermal comfort and to the people's daily social lives. One of the biggest challenges for hot-arid cities is to mitigate against the induced urban heat increase and improve the outdoor thermal. The objective of this study is to propose a pragmatic and useful framework that would improve the outdoor thermal comfort, by being able to evaluate and select minimally invasive urban heat mitigation strategies that could be applied to the existing urban settings in the hot-arid area of Phoenix. The study started with an evaluation of existing microclimate conditions by means of multiple field observations cross a North-South oriented urban block of buildings within Arizona State University’s Downtown campus in Phoenix. The collected data was evaluated and analyzed for a better understanding of the different local climates within the study area, then used to evaluate and partially validate a computational fluid dynamics model, ENVI-Met. Furthermore, three mitigation strategies were analyzed to the Urban Canopy Layer (UCL) level, an increase in the fraction of permeable materials in the ground surface, adding different configurations of high/low Leaf Area Density (LAD) trees, and replacing the trees configurations with fabric shading. All the strategies were compared and analyzed to determine the most impactful and effective mitigation strategies. The evaluated strategies have shown a substantial cooling effect from the High LAD trees scenarios. Also, the fabric shading strategies have shown a higher cooling effect than the Low LAD trees. Integrating the trees scenarios with the fabric shading had close cooling effect results in the High LAD trees scenarios. Finally, how to integrate these successful strategies into practical situations was addressed. / Dissertation/Thesis / Masters Thesis Architecture 2020
319

Sistema móvel para análise de conforto térmico de animais, utilizando método interpolador IDW /

Oliveira Júnior, Arilson José de January 2019 (has links)
Orientador: Silvia Regina Lucas de Souza / Resumo: Em ambientes de produção animal o processo de análise das condições de conforto térmico pode ser realizado mediante o cálculo de índices de conforto térmico e da elaboração de mapas de variabilidade espacial de parâmetros meteorológicos e dos próprios índices de conforto térmico. Os métodos atuais para análise do bem-estar animal, especificamente aqueles por meio de mapas de índices de conforto térmico, são realizados em programas de computador utilizando-se softwares específicos de interpolação de dados. Esses processos, por sua vez, não permitem que avaliações de conforto térmico sejam realizadas facilmente no próprio local de coleta de dados. Assim, esse trabalho foi realizado com o objetivo de desenvolver um sistema para criação de mapas de variabilidade espacial da temperatura do ar e de índices de conforto térmico de animais, utilizando o método interpolador IDW (Inverse Distance Weighted), ou Inverso da Distância Ponderada. O sistema desenvolvido é composto por um aplicativo Android e dispositivos de transmissão e recepção de dados meteorológicos. O aplicativo foi desenvolvido por meio da linguagem de programação orientada a objetos Java, mediante o ambiente de desenvolvimento integrado Android Studio. Já os dispositivos móveis foram criados utilizando-se sensores de baixo custo de temperatura do ar, temperatura de globo negro e umidade relativa, juntamente com microcontroladores de plataforma eletrônica de código aberto – Arduino. O algoritmo desenvolvido para o aplic... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: In animal production environments, the process of analysis of thermal comfort conditions may be carried out through the calculation of the thermal comfort index and the creation of maps showing spatial variabilities of meteorological parameters and the thermal comfort indexes. The current methods for analysis of animal well fare, especially those including maps of thermal comfort indexes, are carried out using computer programs with specific software of data interpolation. On the other hand, these processes don’t allow the evaluations of thermal comfort to be easily performed in the data collection site. Therefore, the aim of this study was developing a system for creation of maps with spatial variability of the air temperature and thermal comfort of animals, using the IDW (Inverse Distance Weighted) interpolation method. The system created is formed by an Android app and devices of transmission and reception of meteorological data. The app was developed using the Java programming language, through the Android Studio integrated development environment. The mobile devices were made using low cost air temperature, black globe temperature and relative humidity sensors, and microcontrollers of open source electronic platform – Arduino. The algorithm developed for the Android app was validated by means of comparing the air temperature figures measured, and those interpolated by the app in a broiler shed. On the other hand, the transmission and reception of data were validated via ... (Complete abstract click electronic access below) / Doutor
320

ADVANCED INDOOR THERMAL ENVIRONMENT CONTROL USING OCCUPANT’S MEAN FACIAL SKIN TEMPERATURE AND CLOTHING LEVEL

Xuan Li (8731800) 20 April 2020 (has links)
<div> <p>People spend most of their time indoors. Because people’s health and productivity are highly dependent on the quality of the indoor thermal environment, it is important to provide occupants with healthy, comfortable and productive indoor thermal environment. However, inappropriate thermostat temperature setpoint settings not only wasted large amount of energy but also make occupants less comfortable. This study intended to develop a new control strategy for HVAC systems to adjust the thermostat setpoint automatically and accordingly to provide a more comfortable and satisfactory thermal environment.</p> <p>This study first trained an image classification model based on CNN to classify occupants’ amount of clothing insulation (clothing level). Because clothing level was related to human thermal comfort, having this information was helpful when determining the temperature setpoint. By using this method, this study performed experimental study to collect comfortable air temperature for different clothing levels. This study collected 450 data points from college student. By using the data points, this study developed an empirical curve which could be used to calculate comfortable air temperature for specific clothing level. The results obtained by using this curve could provide environments that had small average dissatisfaction and average thermal sensation closed to neutral.</p> <p>To adjust the setpoint temperature according to occupants’ thermal comfort, this study used mean facial skin temperature as an indicator to determine the thermal comfort. Because when human feel hot, their body temperature would rise and vice versa. To determine the correlation, we used a long wave infrared (LWIR) camera to non-invasively obtain occupant’s facial thermal map. By processing the thermal map with Haar-cascade face detection program, occupant’s mean facial skin temperature was calculated. By using this method, this study performed experimental study to collect occupant’s mean facial skin temperature under different thermal environment. This study collected 225 data points from college students. By using the data points, this study discovered different intervals of mean facial skin temperature under different thermal environment. </p> <p>Lastly, this study used the data collected from previous two investigations and developed a control platform as well as the control logic for a single occupant office to achieve the objective. The measured clothing level using image classification was used to determine the temperature setpoint. According to the measured mean facial skin temperature, the setpoint could be further adjusted automatically to make occupant more comfortable. This study performed 22 test sessions to validate the new control strategy. The results showed 91% of the tested subjects felt neutral in the office</p> </div> <br>

Page generated in 0.0391 seconds