• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 16
  • Tagged with
  • 16
  • 16
  • 11
  • 6
  • 5
  • 5
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

[en] PRICING THE ANCILLARY SERVICES OF REACTIVE POWER SUPPLY AND GENERATION RESERVE WHEN PROVIDED BY GENERATORS / [pt] REMUNERAÇÃO DOS SERVIÇOS ANCILARES DE SUPORTE DE POTÊNCIA REATIVA E RESERVA DE POTÊNCIA QUANDO PROVIDOS POR GERADORES

PABLO MOTTA RIBEIRO 04 August 2005 (has links)
[pt] Este trabalho apresenta metodologias para definir a remuneração dos geradores que provêem serviços ancilares em função do benefício proporcionado ao sistema. São analisados os serviços ancilares de suporte de potência reativa e reserva de potência. Para o serviço ancilar de suporte de potência reativa, o valor do benefício proporcionado pelos geradores é obtido por meio do custo evitado de alocação de novas fontes de potência reativa. Já para o serviço ancilar de reserva de potência, o benefício é calculado a partir da redução observada no valor esperado de energia não suprida, multiplicada pelo custo unitário de interrupção do sistema de potência. O valor de benefício proporcionado por cada serviço ancilar é determinado por meio de um algoritmo de pontos interiores em um problema de fluxo de potência ótimo. A remuneração que cabe a cada gerador é definida por meio do emprego do método de repartição de custos de Aumann-Shapley, oriundo da Teoria dos Jogos Cooperativos. A aplicação deste método garante que a repartição do benefício entre os geradores seja realizada de forma justa e eficiente. As metodologias propostas para são ilustradas em dois sistemas de potência distintos: o sistema IEEE-RTS e o sistema Sul-Sudeste Brasileiro. Os resultados obtidos são discutidos e a eficácia da metodologia é analisada. / [en] This work presents methodologies to define the remuneration of the generators that provide ancillary services to the power system as a function of the benefit provided to the system. In this work the ancillary services considered are the reactive power supply and the generation reserve. To the ancillary service of reactive power supply, the benefit provided by the generators is calculated by the avoided cost of new reactive power sources. The benefit provided by the ancillary service of generation reserve is calculated as the reduction on the expected energy not supplied, multiplied by the interruption cost of the power system. An optimum power flow is used to determine the benefit provided by each ancillary service. The remuneration of each generator is defined through the cost allocation method of Aumann-Shapley, which belongs to the Cooperative Game Theory. The Aumann-Shapley method guarantees that the payment partition among the generators is fair and efficient. The proposed methodology is applied to the IEEE-RTS power system and the Brazilian South-Southwest power system. The numerical results are discussed and the efficiency of the methodology is analyzed.
12

[en] METHODOLOGY FOR CALCULATING SERVICE PRICE AND REMUNERATION FOR OPERATING RESERVE SUPPLIER AGENTS / [pt] METODOLOGIA PARA O CÁLCULO DO VALOR DO SERVIÇO E DA REMUNERAÇÃO DOS AGENTES FORNECEDORES DE RESERVAS OPERATIVAS

CARLOS JUAREZ VELASCO 25 January 2005 (has links)
[pt] Com a modificação estrutural do setor de produção, transmissão e distribuição de energia elétrica em vários países do mundo, inclusive no Brasil, serviços caracterizados como ancilares, que sempre foram oferecidos de forma integrada com o fornecimento de energia elétrica, sem que fossem remunerados especificamente, devem hoje ser tratados e remunerados de forma independente. A necessidade de otimizar custos, em função dos novos ambientes comerciais, muitas vezes competitivos, tem feito com que os agentes geradores vejam o fornecimento de reserva de potência operativa e a regulação de freqüência como novas oportunidades de prestação de serviços. Com isto, novos custos e responsabilidades foram criadas, o que reforça a necessidade de remuneração desses serviços ancilares. Devem-se valorizar os benefícios por eles agregados ao sistema elétrico, representados pelo aumento da confiabilidade e da qualidade da energia. Assim, questões que merecem ser tratadas cuidadosamente são a determinação dos preços a serem pagos pelos consumidores pelos serviços, a determinação correta da participação de cada agente e a necessidade de mecanismos justos de distribuição dos recursos financeiros recebidos por estes serviços entre os agentes que realmente os forneceram. Neste trabalho desenvolve-se uma estrutura de remuneração dos serviços de reservas operativas e regulação de freqüência, baseada no benefício por eles determinado, premiando-se a eficiência e permitindo-se a recuperação dos custos incorridos. Através de estudos de casos com dados reais verifica-se a consistência da proposta de remuneração, comparando os seus resultados com valores já praticados, e analisando o seu impacto sobre as atuais tarifas de energia elétrica. / [en] Nowadays, with the structural modification of the electric energy industry around the world, including in Brazil, services characterised as ancillary, that always were offered bundled with energy supply, without specific remuneration, should be dealt with independently. The need for cost optimisation, caused by the new commercial environment, sometimes competitive, has made the generating agents to understand operating reserves and frequency regulation as a new opportunity of providing services. Furthermore, new costs and obligations have been created, thus reinforcing the need for these ancillary services to be remunerated. It is necessary to recognise the benefits aggregated to the electric system by ancillary services, represented by improvement of reliability and energy quality. In this way, issues that deserve to be carefully treated are i) the prices to be paid by consumers, ii) the participation of each agent that really provided the service, and iii) the fairness of the mechanism for distribution of the financial resources among the providers. In this work it is developed a structure for the remuneration of operating reserves and frequency regulation, based on the benefit of this services, awarding efficiency and allowing the recuperation of incurred costs. Through study-cases with actual data, it is verified the consistency of the proposal, by comparing its results with values in practice, and by analysing its impact over current electric energy tariffs.
13

[en] VALIDATION OF SYSTEMIC DYNAMIC SIMULATIONS USING SYNCHROPHASOR DATA / [pt] VALIDAÇÃO DE SIMULAÇÕES DINÂMICAS SISTÊMICAS UTILIZANDO REGISTROS SINCROFASORIAIS

03 November 2020 (has links)
[pt] Os Sistemas de Energia Elétrica (SEE) operam de acordo com limites de segurança definidos pelo planejamento da operação através de simulações computacionais. Portanto, os componentes da rede elétrica devem ser devidamente modelados para garantir uma operação segura e econômica. A tecnologia dos sistemas de medição fasorial sincronizada permite a obtenção de registros de distúrbios reais, que podem ser comparados com simulações para verificar sua aderência. Tem-se verificado nos atuais SEE diferenças entre os registros e as simulações computacionais dos eventos observados. Tais diferenças têm ocorrido também no Sistema Interligado Nacional (SIN), principalmente em relação ao desvio de frequência, sendo a resposta simulada menos severa quando comparada ao comportamento observado, podendo levar o SIN a operar em um ponto inseguro com risco de atuação de esquemas regionais de alívio de carga. Nesta dissertação são avaliados os modelos de usinas hidráulicas e termoelétricas e os parâmetros que podem influenciar significativamente a resposta das simulações, com ênfase no desempenho da frequência. Distúrbios que ocorreram no SIN são reproduzidos utilizando casos de tempo real, construídos a partir dos dados de estimadores de estado, em conjunto com uma base de modelos dinâmicos. Os resultados das simulações são comparados com os registros reais obtidos pelas PMUs (Phasor Measurement Unit) instaladas no SIN. Parâmetros como altura de queda, resposta dos reguladores de velocidade e modelagem dinâmica e estática das cargas são investigados. Impactos e simulações do fenômeno multi-infeed são apresentados. Os resultados obtidos mostram a necessidade de melhorias nos modelos e nos parâmetros de entrada das simulações de transitórios eletromecânicos do SIN. Ressalta-se a importância da contínua validação sistêmica e específica dos modelos para o planejamento da operação do SIN. / [en] Electric power systems (EPS) operate according to safety limits defined by the operation planning assessed through computer simulations. Therefore, the components of the electrical grid must be properly represented to ensure secure and economical operation. The technology of synchronized phasor measurement systems allows to obtain records of actual faults, which can be compared to simulation results to check their accuracy. Differences between records and computer simulations of the observed events have been verified in the current EPS. Such differences have also occurred in the Brazilian interconnected system (BIS), mainly related to frequency deviations, with the simulated response being less severe when compared to the observed performance. This may lead the BIS to operate under unsafe conditions, with risk of activating regional protection schemes for load shedding; a possible hasty and undesirable action. In this dissertation, the models of hydraulic and thermoelectric power plants and other parameters that can significantly influence the response of simulations are evaluated, with an emphasis on frequency performance. Disturbances that occurred in the BIS are reproduced using real-time cases, built from state estimator data, together with a collection of dynamic models. The simulation results are compared with the actual records obtained by PMUs (Phasor Measurement Units) installed in the BIS. Parameters such as hydropower head, response of speed regulators and dynamic and static modeling of loads are explored. Impacts and simulations of the multi-infeed phenomenon are also presented. The results show the need for improvements in the models and simulation input parameters of electromechanical transient studies of the BIS. There is a continuous need to observe the systemic and specific validation of models for planning and operation of the BIS.
14

[en] MINIMUM SYNCHRONOUS INERTIA MONITORING AND CALCULATION SYSTEM FOR REAL-TIME DECISION MAKING / [pt] SISTEMA DE MONITORAÇÃO E CÁLCULO DE INÉRCIA MÍNIMA SINCRONIZADA PARA A TOMADA DE DECISÃO EM TEMPO REAL

RAPHAEL BOTTINO ARCOS 27 October 2022 (has links)
[pt] Centros de operação ao redor do mundo têm verificado o aumento da complexidade ao longo dos anos, principalmente pela grande quantidade de novas informações que devem ser consideradas. No sistema elétrico brasileiro não é diferente, impactado pela participação cada vez mais ativa de fontes renováveis, como eólicas e fotovoltaicas, além de elos de corrente contínua. Seguindo uma tendência global, a consideração de valores de inércia sincronizada para a avaliação do desempenho da frequência e de fluxos sistêmicos se faz necessária, configurando-se como uma nova informação a ser exposta à operação em tempo real. Visando garantir mais segurança e confiabilidade ao ambiente de tempo real, o presente trabalho tem como objetivo traduzir os estudos realizados pela equipe de planejamento do ONS para a operação, através de um sistema capaz de monitorar parâmetros como a inércia sincronizada, reserva de potência operativa e outras informações associadas, ampliando a consciência situacional dos usuários. Além disso, o sistema deve promover simulações de contingências severas que possam provocar atuações de esquemas de corte de carga e indicar ações que possam ser realizadas para mitigar o problema. / [en] Operation centers around the world have verified an increase of the complexity throughout the years, mostly due to huge amounts of new information that must be considered. The Brazilian electric system is no different, impacted by the increasingly active participation of renewable sources, such as wind and photovoltaic, as well as direct current links. Following a global trend, the consideration of values of synchronous inertia for the evaluation of the performance of the frequency is necessary, configuring as a new information to be exposed to real-time operation. With the purpose of guaranteeing more safety and reliability to the real-time environment, this work has the goal of translating the studies carried out by the ONS planning team to the operation, through a system capable of monitoring parameters such as synchronous inertia, operating reserve and other associated informations, increasing users situational awareness. Besides that, the system must promote simulations of severe contingencies that may trigger load shedding schemes and indicate actions that can be taken to soften the problem.
15

[en] IMPACT OF LOAD UNCERTAINTIES AND RENEWABLE SOURCES ON THE OPERATING RESERVE REQUIREMENTS IN MULTI-AREA SYSTEMS / [pt] IMPACTO DAS INCERTEZAS DE CARGA E FONTES RENOVÁVEIS NOS REQUISITOS DE RESERVA OPERATIVA EM SISTEMAS MULTIÁREA

BRUNA DOS GUARANYS MARTINS 27 November 2019 (has links)
[pt] A reserva girante é a parcela da geração que deve estar sincronizada, ou que seja possível sincronizar em tempo hábil, de forma a repor a perda de unidades de geração, suprir acréscimos de demanda devido aos erros de previsão, ou ainda lidar com possíveis flutuações na capacidade de geração de fontes renováveis. Desta forma, é crucial que tal parcela esteja dimensionada de modo a suprir tais necessidades de forma adequada. Para tal, deve-se considerar o perfil da demanda do sistema e também as características do sistema de geração. Estimativas imprecisas da carga elétrica podem levar a ocorrências de cortes de carga. Da mesma forma, um superdimensionamento da reserva pode ter como consequência custos excessivos para o consumidor de energia. Uma representação aceitável para carga é considerá-la como uma variável aleatória. Este tipo de modelagem permite que o valor do pico de carga estimado tenha suas incertezas intrinsecamente consideradas. Assim, considerando as variabilidades inerentes à demanda e à geração, é então possível estimar o risco de não suprimento do sistema por meio de métodos baseados em Simulação Monte Carlo (SMC). Tais métodos têm como principal vantagem uma relativa robustez para avaliação de índices que mensuram numericamente o nível de confiabilidade do sistema: e.g., LOLP (loss of load probability). Nesta dissertação será avaliado o impacto das incertezas associadas à demanda, à variabilidade das fontes renováveis e às falhas em equipamentos no dimensionamento da reserva de geração no âmbito da operação de sistemas elétricos. Serão empregadas técnicas baseadas em SMC para avaliar os níveis de confiabilidade, considerando diversas possibilidades de representação da carga em sistemas multiárea. Dentre os cenários testados e discutidos, calculam-se índices de risco para o sistema e por áreas, para avaliar se o sistema é confiável não apenas como um todo, mas também em cada uma de suas regiões operativas. Para avaliar a metodologia proposta, são realizados testes com o sistema IEEE-RTS (Reliability Test System) de modo a responder se os índices de risco por área/sistema estão dentro de níveis aceitáveis. Por fim, é avaliado também o efeito da inserção de fontes renováveis intermitentes na reserva do sistema. / [en] The spinning reserve is the generation quota that must be synchronized (or that can be synchronized in a timely manner) with the aim to restore the loss of generation units, to supply increases in demand due to forecast errors, or to cope with generation capacity fluctuations of renewable sources. Thus, it is crucial that such amount is defined so as to adequately meet the required needs. For this, the system load profile and also the generating system characteristics must be duly considered. Inaccurate estimates of electrical demand can lead to the occurrence of load shedding. Similarly, overinvestment in capacity reserve may result in excessive costs to electric energy consumers. An acceptable representation for the load profile is to consider it as a random variable. This type of modeling allows the estimated peak load value to have its uncertainties intrinsically considered. Therefore, considering the inherent variability of demand and generation, it is then possible to estimate the risk of not supplying the system load through methods based on Monte Carlo simulation (SMC). Such methods have as their main advantage a relative robustness for evaluating indices that numerically measure the reliability level of the system; e.g., LOLP (loss of load probability). In this dissertation, the impact of uncertainties associated with demand, the variability of renewable sources and equipment failures will be evaluated in order to size the amount of generating reserve, within the scope of the operation of electric systems. SMC techniques are used to evaluate the reliability levels, considering several possibilities of load representation in a multi-area system. Among different scenarios analyzed, risk indices are calculated for system and areas, in order to assess whether the grid is reliable as a whole and also for all operating regions. In order to evaluate the proposed methodology, tests are performed with the IEEE-RTS (Reliability Test System) to respond if the area/system risk indices are within acceptable levels. Finally, the effect of inserting intermittent renewable sources into the system reserve is also discussed.
16

[en] A MIXED PARAMETRIC AND NON PARAMETRIC INTERNAL MODEL TO UNDERWRITING RISK FOR LIFE INSURANCE / [pt] MODELO INTERNO MISTO, PARAMÉTRICO E NÃO PARAMÉTRICO DE RISCO DE SUBSCRIÇÃO PARA SEGURO DE VIDA

MARIANA DA PAIXAO PINTO 09 November 2017 (has links)
[pt] Com as falências ocorridas nas últimas décadas, no setor de seguros, um movimento surgiu para desenvolver modelos matemáticos capazes de ajudar no gerenciamento do risco, os chamados modelos internos. No Brasil, a SUSEP, seguindo a tendência mundial, exigiu que as empresas, interessadas em atuar no país, utilizassem um modelo interno para risco de subscrição. Com isto, obter um modelo interno tornou-se primordial para as empresas seguradoras no país. O modelo proposto neste trabalho ilustrado para seguro de vida para risco de subscrição se baseia em Cadeias de Markov, no Teorema Central do Limite, parte paramétrica, e na Simulação de Monte Carlo, parte não paramétrica. Em sua estrutura foi considerada a dependência entre titular e dependentes. Uma aplicação a dados reais mascarados foi feita para analisar o modelo. O capital mínimo requerido calculado utilizando o método híbrido foi comparado com o valor obtido utilizando somente o método paramétrico. Em seguida foi feita a análise de sensibilidade do modelo. / [en] The bankruptcies occurred in recent decades in the insurance sector, a movement arose to develop mathematical models capable of assisting in the management of risk, called internal models. In Brazil, the SUSEP, following the worldwide trend, demanded that the companies, interested in working in the country, using an internal model for underwriting risk. Because of this, developing an internal model has become vital for insurance companies in the country. The proposed model in this work illustrated to life insurance for the underwriting risk was based on the Markov chains, on the Central Limit Theorem to the parametric method, and Monte Carlo Simulation to the non-parametric method. In its structure, the dependence between the holder and dependents was considered. An application to masked real data was made to analyze the model. The minimum required capital calculated using the hybrid method was compared with the value obtained using only the parametric method. Then the sensitivities of the model were investigated.

Page generated in 0.0382 seconds