• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 37
  • 19
  • 6
  • Tagged with
  • 62
  • 40
  • 26
  • 21
  • 21
  • 19
  • 17
  • 17
  • 17
  • 16
  • 16
  • 15
  • 13
  • 13
  • 12
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
51

L'élastographie ultrasonore dynamique vasculaire : une nouvelle modalité d'imagerie non-invasive pour la caractérisation mécanique de la thrombose veineuse

Schmitt, Cédric 04 1900 (has links)
L’accident thromboembolique veineux, tel que la thrombose veineuse profonde (TVP) ou thrombophlébite des membres inférieurs, est une pathologie vasculaire caractérisée par la formation d’un caillot sanguin causant une obstruction partielle ou totale de la lumière sanguine. Les embolies pulmonaires sont une complication mortelle des TVP qui surviennent lorsque le caillot se détache, circule dans le sang et produit une obstruction de la ramification artérielle irriguant les poumons. La combinaison d’outils et de techniques d’imagerie cliniques tels que les règles de prédiction cliniques (signes et symptômes) et les tests sanguins (D-dimères) complémentés par un examen ultrasonographique veineux (test de compression, écho-Doppler), permet de diagnostiquer les premiers épisodes de TVP. Cependant, la performance de ces outils diagnostiques reste très faible pour la détection de TVP récurrentes. Afin de diriger le patient vers une thérapie optimale, la problématique n’est plus basée sur la détection de la thrombose mais plutôt sur l’évaluation de la maturité et de l’âge du thrombus, paramètres qui sont directement corrélées à ses propriétés mécaniques (e.g. élasticité, viscosité). L’élastographie dynamique (ED) a récemment été proposée comme une nouvelle modalité d’imagerie non-invasive capable de caractériser quantitativement les propriétés mécaniques de tissus. L’ED est basée sur l’analyse des paramètres acoustiques (i.e. vitesse, atténuation, pattern de distribution) d’ondes de cisaillement basses fréquences (10-7000 Hz) se propageant dans le milieu sondé. Ces ondes de cisaillement générées par vibration externe, ou par source interne à l’aide de la focalisation de faisceaux ultrasonores (force de radiation), sont mesurées par imagerie ultrasonore ultra-rapide ou par résonance magnétique. Une méthode basée sur l’ED adaptée à la caractérisation mécanique de thromboses veineuses permettrait de quantifier la sévérité de cette pathologie à des fins d’amélioration diagnostique. Cette thèse présente un ensemble de travaux reliés au développement et à la validation complète et rigoureuse d’une nouvelle technique d’imagerie non-invasive élastographique pour la mesure quantitative des propriétés mécaniques de thromboses veineuses. L’atteinte de cet objectif principal nécessite une première étape visant à améliorer les connaissances sur le comportement mécanique du caillot sanguin (sang coagulé) soumis à une sollicitation dynamique telle qu’en ED. Les modules de conservation (comportement élastique, G’) et de perte (comportement visqueux, G’’) en cisaillement de caillots sanguins porcins sont mesurés par ED lors de la cascade de coagulation (à 70 Hz), et après coagulation complète (entre 50 Hz et 160 Hz). Ces résultats constituent les toutes premières mesures du comportement dynamique de caillots sanguins dans une gamme fréquentielle aussi étendue. L’étape subséquente consiste à mettre en place un instrument innovant de référence (« gold standard »), appelé RheoSpectris, dédié à la mesure de la viscoélasticité hyper-fréquence (entre 10 Hz et 1000 Hz) des matériaux et biomatériaux. Cet outil est indispensable pour valider et calibrer toute nouvelle technique d’élastographie dynamique. Une étude comparative entre RheoSpectris et la rhéométrie classique est réalisée afin de valider des mesures faites sur différents matériaux (silicone, thermoplastique, biomatériaux, gel). L’excellente concordance entre les deux technologies permet de conclure que RheoSpectris est un instrument fiable pour la mesure mécanique à des fréquences difficilement accessibles par les outils actuels. Les bases théoriques d’une nouvelle modalité d’imagerie élastographique, nommée SWIRE (« shear wave induced resonance dynamic elastography »), sont présentées et validées sur des fantômes vasculaires. Cette approche permet de caractériser les propriétés mécaniques d’une inclusion confinée (e.g. caillot sanguin) à partir de sa résonance (amplification du déplacement) produite par la propagation d’ondes de cisaillement judicieusement orientées. SWIRE a également l’avantage d’amplifier l’amplitude de vibration à l’intérieur de l’hétérogénéité afin de faciliter sa détection et sa segmentation. Finalement, la méthode DVT-SWIRE (« Deep venous thrombosis – SWIRE ») est adaptée à la caractérisation de l’élasticité quantitative de thromboses veineuses pour une utilisation en clinique. Cette méthode exploite la première fréquence de résonance mesurée dans la thrombose lors de la propagation d’ondes de cisaillement planes (vibration d’une plaque externe) ou cylindriques (simulation de la force de radiation par génération supersonique). DVT-SWIRE est appliquée sur des fantômes simulant une TVP et les résultats sont comparés à ceux donnés par l’instrument de référence RheoSpectris. Cette méthode est également utilisée avec succès dans une étude ex vivo pour l’évaluation de l’élasticité de thromboses porcines explantées après avoir été induites in vivo par chirurgie. / The venous thromboembolism such as the lower limb deep venous thrombosis (DVT) is a vascular pathology characterized by a blood clot formation that induces partial or total vessel lumen occlusion. Pulmonary embolism is a fatal complication of DVT where the clot detaches from the wall, circulates in the blood flow, and produces an obstruction of pulmonary arterial branches. The combination of clinical prediction rules (signs or symptoms) and blood tests (D-dimer testing) coupled to venous ultrasonography (i.e. compression ultrasonography, color Doppler) allows an accurate diagnosis of first DVT. Nevertheless, such clinical tools present poor results to detect recurrent thrombotic events. Then, in order to guide patients towards optimal therapy, the problem is no more to detect the presence of thrombus, but to evaluate its maturity and its age, which are correlated to their mechanical properties (e.g. elasticity, viscosity). The dynamic elastography (DE) has been recently proposed as a novel non-invasive imaging modality capable to characterize the quantitative mechanical properties of tissues. The DE is based on the analysis of acoustical parameters (i.e. velocity, attenuation, wave pattern) of low frequency (10-7000 Hz) shear waves propagating within the probed medium. Such shear waves generated by external vibration, or remotely using ultrasound beam focalisation (radiation force), were tracked using ultra-fast ultrasound or magnetic resonance imaging. A method based on DE and adapted to mechanical characterization of venous thrombosis may allow the quantification of diseases severity in order to improve the final diagnosis. This thesis presents the works related to the development and complete validation of a novel non-invasive elastography imaging method for the quantitative and reliable estimation of mechanical properties of venous thrombosis. In order to fulfil the main objective, it is first necessary to improve knowledge about mechanical behaviours of blood clot (coagulated blood) subjected to a dynamic solicitation similar to DE. The shear storage (elastic behaviour, G’) and loss (viscous behavior, G’’) moduli of porcine blood clots are measured by DE during the blood coagulation kinetics (at 70 Hz) and after completely coagulation (between 50 Hz and 160 Hz). These results are the first dynamic behaviour measurements of blood clots in such wide frequency range. The subsequent step consists in introducing an innovative reference instrument (« gold standard »), called RheoSpectris, dedicated to measure the hyper-frequency viscoelasticity (between 10 Hz and 1000 Hz) of materials and biomaterials. This tool is indispensable to validate new dynamic elastography techniques. A comparative study between RheoSpectris and classical rheometry is performed to validate the measurements on different materials (silicon, thermoplastic, biomaterials, gel). The excellent agreement between both technologies allows to conclude that RheoSpectris is a reliable instrument for mechanical measurements at high frequencies, which is not always possible with current tools. The theoretical basis of a novel elastographic imaging modality, labelled SWIRE (« shear wave induced resonance dynamic elastography ») is presented and validated on vascular phantoms. Such approach allows the characterization of mechanical properties of a confined inclusion (e.g. blood clot) from its resonance (displacement amplification) due to the propagation of judiciously oriented shear waves. SWIRE has also the advantage to amplify the vibration amplitude within the heterogeneity to help for its detection and segmentation. Finally, the method DVT-SWIRE ((« Deep venous thrombosis – SWIRE ») is adapted to the quantitative elasticity estimation of venous thrombosis in the context of clinical use. DVT-SWIRE exploits the first resonance frequency measured within the thrombosis during the plane (vibration of rigid plate) or cylindrical (simulating supersonic radiation force generation) shear waves propagation. The technique is applied on DVT phantoms and the results are compared to those given by the RheoSpectris reference instrument. This method is also used successfully in an ex vivo study for the elasticity assessment of explanted porcine thrombosis surgically induced in vivo.
52

Elastographie pour le suivi des thérapies par ultrasons focalisés et nouveau concept de cavité à retournement temporel pour l'histotripsie

Arnal, Bastien 17 January 2013 (has links) (PDF)
L'émission d'ultrasons focalisés à forte puissance peut être utilisée pour réaliser l'ablation non-invasive de zones pathogènes, de type cancéreuses par exemple. On distingue deux régimes d'ablations : ablation thermique appelée HIFU (" High Intensity Focused Ultrasound ") et ablation mécanique appelée histotripsie utilisant des ondes de chocs focalisées. Au cours de ma thèse, nous avons développé des méthodes de suivi ultrasonore en temps réel à partir d'une technique d'élastographie quantitative (Supersonic Shear wave Imaging). Nous montrerons que des mesures précises des changements d'élasticité au cours des traitements fournissent un suivi et un guidage avec une robustesse aux mouvements du patient. En effet, l'élastographie nous a permis d'une part de cartographier la température et d'autre part de suivre la formation de lésion en temps réel qu'elle soit de type thermique (HIFU) ou mécanique (histotripsie). Nous aborderons aussi une technique d'inversion totale du front d'onde appliquée à SSI qui améliore la sensibilité à la perte d'information due au bruit et à l'hypoéchogénicité existante dans certaines lésions. Enfin, nous présenterons un nouveau concept de cavité à retournement temporel " réglable " pour l'émission d'impulsions de très fortes pressions à partir d'un nombre limité de transducteurs. Notre prototype a permis de générer des ondes de chocs focalisées au sein d'une étendue considérable et de multiplier par 17 la pression d'une sonde d'imagerie conventionnelle. Ainsi, à partir d'électroniques basse-puissance à faible coût, ce dispositif thérapeutique pourrait avoir de nombreuses applications thérapeutiques limitées actuellement par des contraintes géométriques.
53

Cost-effectiveness of NASH screening

Zhang, Eric W. 09 1900 (has links)
No description available.
54

Application of Lorentz Force in Ultrasound-electromagnetic-field-coupled Electrical Impedance Tomography and Elastography / Application de la force de Lorentz à la tomographie d'impédance électrique et à l'élastographie ultrasonore

Sun, Zhishen 21 November 2019 (has links)
La première partie de la thèse étudie le balayage des gradients de conductivité électrique avec la force de Lorentz induite par ultrasons (SECG-UILF). Pour réduire la puissance de stimulation instantanée du transducteur émetteur et en même temps la pression acoustique maximale du transducteur, cette thèse propose d'appliquer l'excitation de l'impulsion ultrasonore à la modulation de fréquence linéaire ou l'excitation de l'impulsion ultrasonore à fréquence sinusoïdale dans SECG-UILF. Pour les gradients de conductivité électrique à balayage avec la force de Lorentz induite par l’ultrasons à la modulation de fréquence linéaire (SECG-LFM-UILF), un signal électrique de puissance instantanée maximale de 39,54 dBm est utilisé pour exciter le transducteur de transmission, ce qui est inférieur de 25,5 dB à la puissance instantanée maximale de l'impulsion étroite haute tension négative (65,05 dBm) adopté dans le SECG-UILF traditionnel. Et en temps, la pression acoustique d'émission maximale dans le SECG-LFM-UILF est inférieure de 0,44 MPa à celle du SECG-UILF traditionnel. Des expériences de SECG-LFM-UILF sont effectuées en utilisant des fantômes de conductivité à la gélose saline à plusieurs formes de conductivité allant de 0,2 S/m à 0,5 S/m, ce qui montre que: (1) le SECG-LFM-UILF peut détecter avec précision la distance longitudinale des gradients de conductivité électrique; (2) le rapport signal sur bruit des images de balayage B reconstituées de la distribution de gradient de conductivité électrique par le SECG-LFM-UILF est comparable à celui obtenu par le biais du SECG-UILF traditionnel; et (3) en utilisant une largeur de bande de fréquence de modulation de 2 MHz et une durée de modulation de 500 μs, une résolution longitudinale de 1 mm est obtenue. Pour balayer des gradients de conductivité électrique avec une force de Lorentz induite par ultrasons à fréquence fréquentielle (SECG-SF-UILF), le schéma de démodulation en phase présente une implémentation matérielle plus simple que le schéma de démodulation IQ, mais ne peut détecter que la moitié de la plage longitudinale. Des expériences de SECG-SF-UILF sont effectuées sur un échantillon de feuille de cuivre à deux couches, qui démontrent qu’en utilisant une largeur de bande de fréquences de 2 MHz et 64 fréquences discrètes, la plage longitudinale de l’échantillon peut être détectée avec précision. La deuxième partie de la thèse étudie l'élastographie à base d'approche de corrélation croisée. Pour élargir la largeur de bande de fréquence du champ de déplacement de l’onde de cisaillement afin d’améliorer la qualité de la carte de vitesse de l’onde de cisaillement, cette partie étudie l’application de la force de Lorentz pour la génération de champs d’onde de cisaillement. Tout d'abord, la génération des sources des ondes de cisaillement sur la surface du support souple à travers le mécanisme de la force de Lorentz est étudiée en stimulant un anneau ou un patch conducteur non ferromagnétique avec un champ magnétique transitoire. La mesure de déplacement à l'aide d'une sonde laser interférométrique confirme les caractéristiques d'origine, de fréquence et d'amplitude de la force de Lorentz. Sous un champ magnétique transitoire dont la vitesse de changement est de 10,44 kTs-1, le patch génère une source de champ des ondes de cisaillement d'amplitude de 100 µm à la surface de l'échantillon de fantôme d'alcool polyvinylique (PVA). Ensuite, le potentiel des champs d'ondes de cisaillement générés pour la reconstruction de la vitesse des ondes de cisaillement basée sur la corrélation croisée est exploré. Sur la base de l’approche de corrélation croisée, les cartes qualitatives de la vitesse des ondes de cisaillement sont reconstruites à partir de 100 cadres des champs de déplacement, à partir desquels les interfaces ou les limites entre des régions de rigidité différente peuvent être clairement reconnues, lesquelles sont complètement dissimulées dans les images ultrasonores / The first part of the thesis studies the scanning electric conductivity gradients with ultrasonically induced Lorentz force (SECG-UILF). To reduce the instantaneous stimulation power to the transmitting transducer and at the same time the peak acoustic pressure from the transducer, this thesis proposes to apply the linearly frequency-modulated ultrasound pulse excitation or the sinusoidal step-frequency ultrasound pulse excitation in SECG-UILF. For the scanning electric conductivity gradients with linearly frequency-modulated ultrasound-induced Lorentz force (SECG-LFM-UILF), electrical signal of peak instantaneous power of 39.54 dBm is used to excite the transmitting transducer, which is 25.5 dB lower than the peak instantaneous power of the negative high-voltage narrow pulse (65.05 dBm) adopted in traditional SECG-UILF; and at the same time, the peak transmitting acoustic pressure in SECG-LFM-UILF is 0.44 MPa lower than that in traditional SECG-UILF. Experiments of SECG-LFM-UILF are done using multi-shaped saline agar phantoms of conductivity ranging from 0.2 S/m to 0.5 S/m, which show that: (1) the SECG-LFM-UILF can detect precisely the longitudinal distance of the electric conductivity gradients; (2) the signal-to-noise ratio of the reconstructed B-scan images of the electrical conductivity gradient distribution by the SECG-LFM-UILF are comparable to that obtained through the traditional SECG-UILF; and (3) using modulation frequency bandwidth of 2 MHz and modulation duration of 500 μs, a longitudinal resolution of 1 mm is achieved. For the scanning electric conductivity gradients with step-frequency ultrasound induced Lorentz force (SECG-SF-UILF), the in-phase demodulation scheme is simpler in hardware implementation than the IQ demodulation scheme but can only detect half of the longitudinal range. Experiments of SECG-SF-UILF are done on a sample of two-layer copper foil, which demonstrate that, using a frequency bandwidth of 2 MHz and 64 discrete frequencies, the longitudinal range of the sample can be detected precisely. The second part of the thesis studies the cross-correlation approach based elastography. To expand the frequency bandwidth of the shear wave displacement field so as to improve the quality of the shear wave velocity map, this part studies application of the Lorentz force for generation of shear wave fields. First, generation of shear wave sources on the soft medium surface through the mechanism of the Lorentz force is investigated by stimulating a non-ferromagnetic conductive ring or patch with a transient magnetic field. The origin and the frequency and amplitude characteristics of the Lorentz force acting on the conductive ring are confirmed by the displacement measurement using an interferometric laser probe. Under a transient magnetic field of changing rate of 10.44 kTs-1, the patch generates a shear wave field source of amplitude of 100 μm at the surface of the sample of polyvinyl alcohol (PVA) phantom. The shear wave fields created and propagating in the PVA phantom by experiments agree qualitatively well with the theoretical shear wave fields calculated through the analytical Green function solution. Then, the potential of the generated shear wave fields for the cross-correlation based shear wave velocity reconstruction is explored. Based on the cross-correlation approach, the qualitative shear wave velocity maps are reconstructed from 100 frames of the displacement fields, from which the interfaces or boundaries between regions of different stiffness can be clearly recognized, which are completely concealed in the ultrasound images
55

Amélioration des techniques d’ablation pour le traitement des arythmies cardiaques : nouvelles modalités diagnostiques et thérapeutiques par ultrasons / Diagnostic and therapeutic ultrasound techniques to improve ablation of cardiac arrhythmias

Bessière, Francis 06 November 2019 (has links)
A la croisée des chemins entre médecine et physique des ultrasons, ce travail de thèse s’est intéressé à l’apport de solutions diagnostiques et de thérapeutiques novatrices dans le domaine de l’électrophysiologie cardiaque. Un système capable de délivrer des ultrasons focalisés dans le cœur par voie transoesophagienne sous guidage par ultrasons a été développé et testé in vivo chez 6 porcs. Les tirs HIFU ont été délivrés sur les oreillettes et les ventricules. Lors de l'autopsie, une analyse visuelle a démontré la présence de lésions thermiques dans les zones ciblées chez 3 animaux. Ces lésions ont été confirmées par analyse histologique (taille moyenne: 5,5 mm2 x 11 mm2). Aucune lésion thermique œsophagienne n'a été observée. Un animal a présenté une bradycardie due à un bloc auriculo-ventriculaire, ce qui a permis de confirmer une réelle interaction entre les tirs HIFU et le tissu nodal cardiaque. Nous avons cependant observé un manque de précision, principalement lié aux mouvements cardiaques ainsi qu’aux structures anatomiques situées entre les zones ciblées et le transducteur de thérapie. Ces difficultés ont été principalement reliées à l’anatomie du modèle porcin, loin de celle de l’être humain. La recherche d'un meilleur modèle a conduit à des tests d'imagerie concluants sur des babouins.Des expériences supplémentaires ont été conduites afin d'améliorer la cartographie des arythmies ventriculaires et le suivi de la formation de lésions pendant l'ablation.Des expériences ont été menées sur les ventricules gauches de quatre coeurs de porcs en mode travaillant. Le protocole visait à démontrer que différents modèles d'activation mécanique pouvaient être observés, que le ventricule soit en rythme sinusal, stimulé depuis l'épicarde ou l'endocarde. Des acquisitions d’imagerie de déformation électromécanique (EWI) ont été enregistrées sur les faces antérieures, latérales et postérieures du ventricule gauche. Les boucles ont été ensuite analysées à l’aveugle par deux lecteurs indépendants.Les interprétations des séquences EWI étaient correctes dans 89% des cas. Le taux de concordance globale entre les deux lecteurs était de 83%. Dans un ventricule stimulé, l'origine du front d'onde était focale et provenait de l'endocarde ou de l'épicarde stimulé. En rythme sinusal, le front d'onde était activé depuis tout l'endocarde, en direction de l'épicarde, à une vitesse de 1,7 ± 0,28 m.s-1. Les vitesses du front d'onde ont été mesurées respectivement lorsque l'endocarde ou l'épicarde étaient stimulés à une vitesse de 1,1 ± 0,35 m.s -1 et 1,3 ± 0,34 m.s-1 (p = NS). Nous avons aussi démontré sur des échantillons ex-vivo que l'imagerie trans oesophagienne par analyse des ondes de cisaillement (élastographie) pouvait cartographier l'étendue des lésions HIFU. Des tirs HIFU ont été réalisés à l'aide de la sonde trans oesophagienne sur des échantillons de blancs de poulet (n = 3), puis sur un modèle porcin ex vivo d'oreillette (gauche, n = 2) et de ventricule gauche (n = 1). L’élastographie a fourni des cartes de rigidité des tissus avant et après l'ablation. Les zones des lésions ont été obtenues par analyse et quantification des changements de couleur des tissus puis ont été comparées aux images par élastographie. Dans le blanc de poulet, la rigidité est passée en moyenne de 4.8±1.1 kPa à 20.5±10.0 kPa (ratio 5.0±3.2). Dans le ventricule gauche, la rigidité est passée en moyenne de 21.2±3.3kPa à 73.8±13.9kPa (ratio 3.7±1.2). Dans l’oreillette gauche, la rigidité est passée en moyenne de 12.2±4.3 kPa à 30.3±10.3 (ratio 3.2±2.0). En histologie, la taille des lésions variait de 0.1 à 1.5 cm2 dans la zone du plan d'imagerie. Les caractéristiques morphométriques étaient similaires entre histologie et élastographie / At the crossroads of medicine and physics, this work aimed to provide innovative diagnostic and therapeutic tools based on ultrasound, in the field of cardiac electrophysiology. A system capable of delivering HIFU into the heart by a transesophageal route using ultrasound (US) imaging guidance was developed and tested in vivo in six male pigs. HIFU exposures were performed on atria and ventricles. At the time of autopsy, visual inspection identified thermal lesions in the targeted areas in three of the animals. These lesions were confirmed by histologic analysis (mean size: 5.5 mm2 x 11mm2). No esophageal thermal injury was observed. One animal presented with bradycardia due to an atrio-ventricular block, which provides real-time confirmation of an interaction between HIFU and the electrical circuits of the heart. There was still a lack of accuracy, mainly related to cardiac motion, and to anatomical structures in between the targets and the transducer. It was mainly related to the in vivo model and its anatomy, far from the human’s. The search for a better model led to conclusive imaging tests on baboons. Additional experiments were conduced in order to improve the mapping of ventricular arrhythmias and the monitoring of lesion formation during ablation. First, experiments were conducted on left ventricles of four isolated working mode swine hearts. The protocol aimed at demonstrating that different patterns of mechanical activation could be observed whether the ventricle was in sinus rhythm, paced from the epicardium, or from the endocardium. Electromechanical wave imaging (EWI) acquisitions were recorded on the anterior, lateral, and posterior segments of the left ventricle. Loop records were blindly assigned to two readers. EWI sequences interpretations were correct in 89% of cases. The overall agreement rate between the two readers was 83%. When in a paced ventricle, the origin of the wave front was focal and originating from the endocardium or the epicardium. In sinus rhythm, wave front was global and activated within the entire endocardium towards the epicardium at a speed of 1.7±0.28 m.s-1. Wave front speeds were respectively measured when the endocardium or the epicardium were paced at a speed of 1.1 ± 0.35 m.s-1 vs 1.3±0.34 m.s-1 (p=NS). Lastly, we investigated the feasibility of a dual therapy and imaging approach with the same transoesophageal device. We demonstrated on ex-vivo samples that transoesophageal shear wave imaging (SWE) can map the extent of the HIFU lesions. HIFU ablation was performed with the transoesophageal probe on ex-vivo chicken breast samples (n=3), then atrium (left, n=2) and ventricle (left n=1, right n=1) of swine heart tissues. SWE provided stiffness maps of the tissues before and after ablation. Areas of the lesions were obtained by tissue color change with gross pathology and compared to SWE. Shear modulus of the ablated zones increased from 4.8±1.1 kPa to 20.5+/-10.0 kPa (ratio 5.0±3.2) in the chicken breast, from 12.2±4.3 kPa to 30.3±10.3 (ratio 3.2±2.0) in the atria and from 21.2±3.3kPa to 73.8±13.9kPa (ratio 3.7±1.2) in the ventricles. On gross pathology, the size of the lesions ranged from 0.1 to 1.5cm2 in the imaging plane area and morphometric characteristics were fitting with elasticity-estimated depths and widths of the lesions
56

Suivi par élastographie ultrasonore après réparation endovasculaire d’anévrisme aorto-iliaque : étude de faisabilité in vivo

Bertrand-Grenier, Antony 12 1900 (has links)
No description available.
57

Association entre la stéatose hépatique non alcoolique et les hyperchylomicronémies familiale et multifactorielle

Maltais, Mélanie 08 1900 (has links)
La stéatose hépatique non alcoolique (NAFLD) est une affection du foie qui est causée par l’accumulation hépatique de triglycérides. Elle présente plusieurs degrés qui vont de la stéatose hépatique seule à la stéatohépatite avec fibrose. L’obésité et les autres éléments du syndrome métabolique, dont le diabète et l’hypertriglycéridémie, sont des facteurs de risque importants de la NAFLD, laquelle touche entre 20% et 29% des Canadiens. Ces statistiques sont alarmantes, surtout en sachant qu’aucun traitement n’est actuellement disponible pour cette condition et prenant compte de l’augmentation de la prévalence de l’obésité. La lipoprotéine lipase (LPL) hydrolyse les triglycérides contenus dans les lipoprotéines de très basse densité (VLDL) et dans les chylomicrons. La LPL est très souvent régulée à la baisse dans le syndrome métabolique de sorte que certains patients présentent des taux de triglycérides sanguins de plus de 10 mmol/L, comme les patients avec hyperchylomicronémie multifactorielle (MCS pour multifactorial chylomicronemia syndrome). Les chylomicronémies comprennent également celle causée par une déficience totale en LPL, appelée l’hyperchylomicronémie familiale (FCS pour familial chylomicronemia syndrome). La FCS et la MCS sont ainsi deux dyslipidémies caractérisées par une hypertriglycéridémie sévère, laquelle est associée à un risque augmenté de pancréatites. Toutefois, alors que la FCS est monogénique, la MCS est multifactiorielle et liée directement à l’expression du syndrome métabolique avec une influence importante de l’environnement. Les résultats de ce mémoire comparent l’expression de la NAFLD chez les patients atteints de FCS et MCS. L’évaluation par élastographie impulsionnelle de l’expression de la NAFLD a été effectuée chez 18 patients FCS et 18 patients MCS, appariés pour l’âge et le sexe. Des résultats du paramètre d’atténuation contrôlé (CAP) ≥ 280 dB/m, suggérant une NAFLD, ont été rencontrés chez 50% des FCS et 83,3% des MCS. La différence entre les degrés de stéatose hépatique chez les deux groupes est significative avec une valeur de p de 0,03. De plus, seulement 22,2% des patients FCS avec NAFLD sont obèses comparativement à 71,4% chez les patients MCS (p=0,001). Il est aussi intéressant de relever que les patients FCS présentent une NAFLD même en présence d’un indice de masse corporelle très faible (IMC < 18 kg/m2). Par ailleurs, le score de CAP chez les FCS serait négativement corrélé avec le nombre de 2 pancréatites aigues (p=0,004). Notre étude démontre que la NAFLD est fréquemment observée chez les patients FCS et chez les patients MCS. De plus, la NAFLD s’exprimerait indépendamment de l’IMC chez les patients FCS, contrairement à ce que l’on observe chez les patients MCS. Finalement, la NAFLD chez les patients FCS pourrait être associée à une fréquence plus faible de pancréatites aigues. / Nonalcoholic fatty liver disease (NAFLD) is a disorder caused by hepatic triglyceride accumulation. It ranges from hepatic steatosis to steatohepatitis with fibrosis. Obesity and other elements of the metabolic syndrome, such as hypertriglyceridemia and type 2 diabetes, are risk factors for NAFLD, which affects between 20% and 29% of Canadians. These statistics are alarming, especially knowing that there is still no treatment for this condition and considering the increasing prevalence of obesity. Lipoprotein lipase (LPL) hydrolyzes triglycerides contained in very low-density lipoproteins (VLDL) and chylomicrons. LPL is often down-regulated in the metabolic syndrome and some patients may present triglycerides level higher than 10 mmol/L, as multifactorial chylomicronemia syndrome (MCS). Chylomicronemia also characterizes total LPL deficiency, known as familial chylomicronemia syndrome (FCS). FCS and MCS are two dyslipidemias associated with severe hypertriglyceridemia, which is associated with increased risk of recurrent acute pancreatitis. Whereas FCS is monogenic, MCS is polygenic and directly related to the metabolic syndrome with a significant influence of the environment. Results of the present study compare the expression of NAFLD in FCS and MCS patients. NAFLD was assessed using transient elastography performed in 18 FCS and 18 MCS patients matched for age and sex. Controled attenuation parameter (CAP) score ≥ 280 dB/m, suggesting NAFLD expression, were observed in 50% of FCS and 83.3% of MCS. The difference between degrees of hepatic steatosis in both groups is significant with a p-value of 0.036. In addition, only 22.2% of FCS with NAFLD are obese compared to 71.4% for MCS (p = 0.001). It is also interesting to note that FCS patients have NAFLD even in the presence of a very low body mass index (BMI<18 kg / m2). Besides, CAP score in FCS was negatively correlated with the number of acute pancreatitis (p=0.004). Our study shows that NAFLD was frequently observed in FCS and MCS but occurred independently of BMI and could be associated with a lower occurrence of acute pancreatitis.
58

Développement d'une nouvelle méthode de caractérisation tissulaire basée sur l'élastographie ultrasonore : application pour le dépistage précoce du cancer du sein

Ouared, Abderrahmane 09 1900 (has links)
Le cancer du sein est le cancer le plus fréquent chez la femme. Il demeure la cause de mortalité la plus importante chez les femmes âgées entre 35 et 55 ans. Au Canada, plus de 20 000 nouveaux cas sont diagnostiqués chaque année. Les études scientifiques démontrent que l'espérance de vie est étroitement liée à la précocité du diagnostic. Les moyens de diagnostic actuels comme la mammographie, l'échographie et la biopsie comportent certaines limitations. Par exemple, la mammographie permet de diagnostiquer la présence d’une masse suspecte dans le sein, mais ne peut en déterminer la nature (bénigne ou maligne). Les techniques d’imagerie complémentaires comme l'échographie ou l'imagerie par résonance magnétique (IRM) sont alors utilisées en complément, mais elles sont limitées quant à la sensibilité et la spécificité de leur diagnostic, principalement chez les jeunes femmes (< 50 ans) ou celles ayant un parenchyme dense. Par conséquent, nombreuses sont celles qui doivent subir une biopsie alors que leur lésions sont bénignes. Quelques voies de recherche sont privilégiées depuis peu pour réduire l`incertitude du diagnostic par imagerie ultrasonore. Dans ce contexte, l’élastographie dynamique est prometteuse. Cette technique est inspirée du geste médical de palpation et est basée sur la détermination de la rigidité des tissus, sachant que les lésions en général sont plus rigides que le tissu sain environnant. Le principe de cette technique est de générer des ondes de cisaillement et d'en étudier la propagation de ces ondes afin de remonter aux propriétés mécaniques du milieu via un problème inverse préétabli. Cette thèse vise le développement d'une nouvelle méthode d'élastographie dynamique pour le dépistage précoce des lésions mammaires. L'un des principaux problèmes des techniques d'élastographie dynamiques en utilisant la force de radiation est la forte atténuation des ondes de cisaillement. Après quelques longueurs d'onde de propagation, les amplitudes de déplacement diminuent considérablement et leur suivi devient difficile voir impossible. Ce problème affecte grandement la caractérisation des tissus biologiques. En outre, ces techniques ne donnent que l'information sur l'élasticité tandis que des études récentes montrent que certaines lésions bénignes ont les mêmes élasticités que des lésions malignes ce qui affecte la spécificité de ces techniques et motive la quantification de d'autres paramètres mécaniques (e.g.la viscosité). Le premier objectif de cette thèse consiste à optimiser la pression de radiation acoustique afin de rehausser l'amplitude des déplacements générés. Pour ce faire, un modèle analytique de prédiction de la fréquence de génération de la force de radiation a été développé. Une fois validé in vitro, ce modèle a servi pour la prédiction des fréquences optimales pour la génération de la force de radiation dans d'autres expérimentations in vitro et ex vivo sur des échantillons de tissu mammaire obtenus après mastectomie totale. Dans la continuité de ces travaux, un prototype de sonde ultrasonore conçu pour la génération d'un type spécifique d'ondes de cisaillement appelé ''onde de torsion'' a été développé. Le but est d'utiliser la force de radiation optimisée afin de générer des ondes de cisaillement adaptatives, et de monter leur utilité dans l'amélioration de l'amplitude des déplacements. Contrairement aux techniques élastographiques classiques, ce prototype permet la génération des ondes de cisaillement selon des parcours adaptatifs (e.g. circulaire, elliptique,…etc.) dépendamment de la forme de la lésion. L’optimisation des dépôts énergétiques induit une meilleure réponse mécanique du tissu et améliore le rapport signal sur bruit pour une meilleure quantification des paramètres viscoélastiques. Il est aussi question de consolider davantage les travaux de recherches antérieurs par un appui expérimental, et de prouver que ce type particulier d'onde de torsion peut mettre en résonance des structures. Ce phénomène de résonance des structures permet de rehausser davantage le contraste de déplacement entre les masses suspectes et le milieu environnant pour une meilleure détection. Enfin, dans le cadre de la quantification des paramètres viscoélastiques des tissus, la dernière étape consiste à développer un modèle inverse basé sur la propagation des ondes de cisaillement adaptatives pour l'estimation des paramètres viscoélastiques. L'estimation des paramètres viscoélastiques se fait via la résolution d'un problème inverse intégré dans un modèle numérique éléments finis. La robustesse de ce modèle a été étudiée afin de déterminer ces limites d'utilisation. Les résultats obtenus par ce modèle sont comparés à d'autres résultats (mêmes échantillons) obtenus par des méthodes de référence (e.g. Rheospectris) afin d'estimer la précision de la méthode développée. La quantification des paramètres mécaniques des lésions permet d'améliorer la sensibilité et la spécificité du diagnostic. La caractérisation tissulaire permet aussi une meilleure identification du type de lésion (malin ou bénin) ainsi que son évolution. Cette technique aide grandement les cliniciens dans le choix et la planification d'une prise en charge adaptée. / Breast cancer is the most frequent cancer in women and the leading cause of death for women between 35 and 55 years old. In Canada, more than 20,000 new cases are diagnosed each year. Most of the previous works have shown that life expectancy is closely related to the precocity of diagnosis. Current diagnostic imaging methods such as mammography, sonography, MRI present limitations such as irradiation (mammography), low specificity and low resolution (sonography) and high cost (MRI). For example, about 95% of abnormalities detected by mammography are proven to be benign lesions after complementary examinations (biopsy). Sonography is useful as a complementary examination but the low resolution of its images, its low specificity (54% for women less than 50 years) and its operator dependent interpretation seriously limit the use of this modality alone. MRI is a non-invasive technique with a relatively high sensitivity (86% for women below 50 years), but its limitations are the high cost and the waiting time for medical examination, which dedicate it as a monitoring technique in high-risk patients. It is therefore necessary to examine new noninvasive and cost effective methods. In this context, dynamic elastography is a promising approach. It is an emerging quantitative medical imaging technique inspired from palpation and based on the determination of elastic properties (stiffness) of tissues. This thesis aims the development of a novel dynamic ultrasound elastography method for early detection of breast lesions. One of the main problems of dynamic elastography techniques using remote palpation (acoustic radiation force) is the strong attenuation of shear waves. After few wavelengths of propagation, displacement amplitudes considerably decrease and their tracking becomes difficult even impossible. This problem greatly affects biological tissue characterization. Moreover, these techniques give only the information about elasticity while recent studies show that some benign lesions have the same elasticity as malignant lesions which affect the specificity of these techniques and motivate investigation of other physical parameters (e.g. viscosity). The first objective of this thesis is to optimize the acoustic radiation force using frequency adaptation to enhance the amplitude of displacements. An analytical model has been developed to predict the optimal frequency for the generation of the radiation force. Once validated on phantoms (in vitro), this model was used for the prediction of the optimal frequencies for the generation of the radiation force in tissue mimicking phantoms and ex vivo human breast cancer samples obtained after total mastectomy. Gains in magnitude were between 20% to158% for in vitro measurements on agar-gelatin phantoms, and 170% to 336% for ex vivo measurements on a human breast sample, depending on focus depths and attenuations of tested samples. The signal-to-noise ratio was also improved by more than four folds with adapted sequences. We conclude that frequency adaptation is a complementary technique that is efficient for the optimization of displacement amplitudes. This technique can be used safely to optimize the deposited local acoustic energy, without increasing the risk of damaging tissues and transducer elements. In the second part of this thesis, a prototype of an ultrasound probe for the generation of a specific type of adaptive shear waves called ''adaptive torsional shear waves'' has been developed. The goal was to use the optimized radiation force (developed in the first part) to generate adaptive torsional shear wave, and prove their utility in improving the amplitude of displacement. During their inward propagation, the amplitude of displacement generated by torsional shear waves was enhanced and the signal to noise ratio improved due to the constructive interferences. Torsional shear waves can also resonate heterogeneities which further enhance the displacement contrast between suspicious masses and its surrounding medium. Finally, in the context of assessment of mechanical proprieties of tissue, the last step of this thesis is to develop an inverse problem based on the propagation of adaptive torsional shear waves to estimate the viscoelastic parameters. A finite element method (FEM) model was developed to solve the inverse wave propagation problem and obtain viscoelastic properties of interrogated media. The inverse problem was formulated and solved in the frequency domain and its robustness was evaluated. The proposed model was validated in vitro with two independent rheology methods on several homogeneous and heterogeneous breast tissue mimicking phantoms over a broad range of frequencies (up to 400Hz). The obtained results were in good agreement with reference rheology methods with discrepancies between 8% and 38% for shear modulus and from 9% to 67% for loss modulus. The robustness study showed that the proposed inverse problem solution yielded a good estimation of the storage (19%) and loss moduli (32%) even with very noisy signals.
59

Élastographie par résonance magnétique et onde de pression guidée

Tardieu, Marion 16 July 2014 (has links) (PDF)
Les propriétés mécaniques des tissus biologiques sont des paramètres importants en médecine : ce sont des biomarqueurs du fonctionnement normal ou pathologique d'un tissu. En effet, ces propriétés peuvent être affectées par certaines conditions mécaniques telles que l'application d'une contrainte externe, comme l'hypertension ou un traumatisme, mais également par la présence de certaines maladies, telles que le cancer, la fibrose, l'inflammation, la maladie d'Alzheimer, ou bien tout simplement avec l'âge. La palpation réalisée par le médecin permet de discerner ces changements mais ce geste est qualitatif et ne peut accéder à des organes profonds. L'élastographie-IRM reste une méthode quantitative, robuste, d'une grande précision, qui permet de sonder l'élasticité et la viscosité des tissus. Elle consiste à mesurer le champ de déplacement d'une onde de cisaillement induite dans l'organe ciblé par une technique IRM en contraste de phase. Les modules viscoélastiques sont alors déduits après inversion de l'équation d'onde. Malgré cela, la justesse de cette technique n'a pas encore été pleinement établie. L'élastographie-IRM est en cours d'implémentation en routine clinique sur des patients atteints de maladies hépatiques chroniques ou bien pour caractériser des tumeurs dans le cas de cancer du sein. L'application aux autres organes protégés, tels que le cerveau ou les poumons, reste encore du domaine de la recherche à cause de la difficulté d'y induire des ondes mécaniques (protection naturelle de la boîte crânienne ou de la cage thoracique). C'est dans ce contexte qu'intervient un volet de mon travail de thèse : la mise en place, la caractérisation et l'optimisation d'un système induisant des ondes mécaniques dans les organes profonds. L'approche originale suivie a été d'utiliser les voies naturelles permettant d'amener l'onde de pression aux poumons ou bien à l'encéphale, différente des approches classiques consistant à traverser les barrières protectrices. Ce générateur d'onde de pression nous a permis d'obtenir des amplitudes d'onde allant de 6 µm à 30 µm dans l'ensemble du cerveau, amplitudes suffisantes afin d'en déduire les modules viscoélastiques du cerveau entier. D'autre part, un travail important s'est attaché à la réalisation d'un schéma original de correction des mouvements du patient en élastographie-IRM. Nous avons mis en évidence comment ces mouvements peuvent entraîner une discordance des composantes du champ de déplacement, nécessitant alors d'être corrigées. La correction proposée est composée d'une première étape dont la finalité est de recaler spatialement l'ensemble des volumes acquis, puis d'une seconde étape permettant de rétablir les composantes du champ de déplacement dans la même base orthonormée. Nous avons évalué numériquement et expérimentalement le biais induit quand aucunes corrections n'étaient appliquées sur ces données ainsi que l'apport de ces deux étapes de correction. Un travail préliminaire sur l'étude de la reproductibilité des acquisitions (phase en particulier) a été nécessaire. Enfin, l'ensemble des résultats de ces deux volets nous ont permis de réaliser des acquisitions d'élastographie du cerveau complet et d'obtenir des cartes du champ de déplacement de qualité. Ainsi, nous avons pu montrer la tendance des ondes mécaniques à suivre les directions privilégiées des fibres du cerveau, résultats que nous avons commencé à confronter aux observations faites en DTI.
60

Applications de la force de Lorentz en acoustique médicale / Applications of Lorentz force in medical acoustics

Grasland-Mongrain, Pol 12 December 2013 (has links)
La capacité de la force de Lorentz à relier un déplacement mécanique à un courant électrique présente un intérêt certain pour l'acoustique médicale, et trois applications ont été étudiées dans cette thèse. Dans la première partie de ce travail, un hydrophone a été développé pour effectuer des champs de vitesse acoustique. Cet hydrophone était constitué d'un fil de cuivre vibrant dans un champ magnétique. Un modèle a été élaboré pour déterminer une relation entre la pression acoustique et le courant électrique mesure, qui est induit par force de Lorentz lorsque le fil vibre dans un champ acoustique. Un prototype a ensuite été conçu et sa résolution spatiale, sa réponse fréquentielle, sa sensibilité, sa résistance et sa réponse directionnelle ont été examinées. Une méthode d'imagerie appelée Tomographie d'Impedance Electrique par Force de Lorentz a aussi été étudiée. Dans cette méthode, un tissu biologique est déplacé par ultrasons dans un champ magnétique, ce qui induit un courant électrique par force de Lorentz. L'impédance électrique du tissu peut ensuite être déduite de la mesure du courant. Cette technique a été appliquée pour réaliser des images d'un fantôme de gélatine, d'un muscle de bœuf, et d'une lésion thermique dans un échantillon de poulet. Cela a montré que la méthode est potentiellement utile pour fournir un contraste supplémentaire à des images ultrasonores classiques. Enfin, cette thèse a démontré que des ondes de cisaillement peuvent être générées dans des tissus mous par force de Lorentz. Cela a été réalisé en appliquant un courant électrique par deux électrodes dans un solide mou place dans un champ magnétique. Des ondes de cisaillement ont été observées dans des échantillons de gélatine et de foie. La vitesse des ondes de cisaillement a été utilisée pour calculer l'élasticité et leur source pour cartographier la conductivité électrique des échantillons / The ability of the Lorentz force to link a mechanical displacement to an electrical current presents a strong interest for medical acoustics, and three applications were studied in this thesis. In the first part of this work, a hydrophone was developed for mapping the particle velocity of an acoustic field. This hydrophone was constructed using a thin copper wire and an external magnetic field. A model was elaborated to determine the relationship between the acoustic pressure and the measured electrical current, which is induced by Lorentz force when the wire vibrates in the acoustic field of an ultrasound transducer. The built prototype was characterized and its spatial resolution, frequency response, sensitivity, robustness and directivity response were investigated. An imaging method called Lorentz Force Electrical Impedance Tomography was also studied. In this method, a biological tissue is vibrated by ultrasound in a magnetic field, which induces an electrical current by Lorentz force. The electrical impedance of the tissue can be deduced from the measurement of the current. This technique was applied for imaging a gelatin phantom, a beef muscle sample, and a thermal lesion in a chicken breast sample. This showed the method may be useful for providing additional contrast to conventional ultrasound imaging. Finally, this thesis demonstrated that shear waves can be generated in soft tissues using Lorentz force. This work was performed by applying an electrical current with two electrodes in a soft solid placed in a magnetic field. Shear waves were observed in gelatin phantom and liver sample. The speed of the shear waves were used to compute elasticity and their source to map the electrical conductivity of the samples

Page generated in 0.0373 seconds