• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 34
  • 2
  • Tagged with
  • 36
  • 10
  • 10
  • 9
  • 8
  • 8
  • 8
  • 5
  • 5
  • 5
  • 5
  • 5
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Μελέτη των κύριων παραμέτρων ενός ευζωνικού δικτύου μέσω των γραμμών ηλεκτρικής ισχύος (BPL)

Μιλτιάδου, Μίλτος 08 February 2010 (has links)
Η επίδραση της τεχνολογίας BPL (Broadband over Power Lines) στη ΔΕΗ, αλλά και στους φορείς ρύθμισης και λειτουργίας της -αναμενόμενης- απελευθερωμένης αγοράς ενέργειας, όπως είναι ο Διαχειριστής Ελληνικού Συστήματος Μεταφοράς Ηλεκτρικής Ενέργειας (ΔΕΣΜΗΕ), θα είναι άμεση και καταλυτική. Η ευρυζωνική μετάδοση πληροφορίας μέσω των γραμμών ηλεκτρικής ισχύος έχει τη δυνατότητα να προσφέρει υπηρεσίες τόσο στις επιχειρήσεις ηλεκτρικής ενέργειας (στην περίπτωσή μας τη ΔΕΗ) όσο και στους καταναλωτές. Με την εφαρμογή της τεχνολογίας BPL στο δίκτυο της ΔΕΗ οι γραμμές ηλεκτρικής ισχύος, εκτός από τη μεταφορά και τη διανομή ηλεκτρικής ενέργειας, μπορούν ταυτόχρονα να μεταδώσουν πληροφορία με ρυθμό μετάδοσης που φτάνει, προς το παρόν, τα 200 Mbps στο φυσικό επίπεδο. Μερικές από τις υπηρεσίες που προσφέρει η τεχνολογία BPL είναι υπηρεσίες τηλεφωνίας (VoIP), ευρυζωνική πρόσβαση στο διαδίκτυο, υπηρεσία τηλεόρασης (internet TV), υπηρεσία ραδιοφώνου, δυνατότητα φορητότητας και κινητικότητας των υπηρεσιών διαδικτύου, αυτοματοποίηση κατοικίας, απομακρυσμένος έλεγχος και λειτουργία του οικιακού εξοπλισμού, δυναμική ρύθμιση της κατανάλωσης ηλεκτρικής ενέργειας, παρακολούθηση για λόγους ασφάλειας, παιχνίδια βασισμένα στο διαδίκτυο, εφαρμογές quadruple play κ.ά. Η πρόσβαση των καταναλωτών πραγματοποιείται με ασύρματο τρόπο (Wi-Fi) από τη γραμμή χαμηλής τάσης (σύνδεση στο μετρητή του χρήστη) ή κατευθείαν από τη γραμμή μέσης τάσης. Ο νέος αυτός τρόπος ευρυζωνικής πρόσβασης στο διαδίκτυο είναι ιδιαίτερα σημαντικός, γιατί δε χρειάζεται επενδύσεις για νέα υποδομή, εφόσον οι γραμμές ηλεκτρικής ισχύος καλύπτουν σχεδόν όλες τις κατοικημένες περιοχές του πλανήτη. Ιδιαίτερα σε περιοχές αραιοκατοικημένες ή με ελάχιστη τηλεπικοινωνιακή υποδομή, η τεχνολογία BPL αποτελεί ίσως τη μοναδική λύση για ευρυζωνικές υπηρεσίες. Στις επιχειρήσεις ηλεκτρικής ενέργειας προσφέρονται πολλαπλές και ιδιαίτερης σημασίας δυνατότητες. Μερικές από αυτές είναι η αυτόματη ανάγνωση μετρητών και η τιμολόγηση, η αυτόματη σύνδεση/αποσύνδεση φορτίων, η μέτρηση και η απεικόνιση των δεδομένων του δικτύου διανομής (τάση, ρεύμα, θερμοκρασία περιβάλλοντος, πραγματική ισχύς, άεργος ισχύς, συντελεστής ισχύος), η διαχείριση της ζήτησης, η μείωση των εκπομπών CO2 λόγω της βελτίωσης της ενεργειακής αποδοτικότητας, η ανίχνευση κλοπής ηλεκτρικής ενέργειας, ο εντοπισμός βλαβών, η απομόνωση και άμεση αποκατάσταση σφαλμάτων, η προληπτική συντήρηση του δικτύου (εναέριο και υπόγειο), η διαχείριση και ο προγραμματισμός του προσωπικού συντήρησης, η διαγνωστική παρακολούθηση του δικτύου, η διαχείριση ασφάλειας του δικτύου. Επιπρόσθετα, προσφέρεται η δυνατότητα στη διοίκηση να αναπτύξει, να ρυθμίσει και να ελέγξει την απελευθερωμένη αγορά ηλεκτρικής ενέργειας. Όλη η πληροφορία για τις συνθήκες λειτουργίας του δικτύου ηλεκτρικής ενέργειας θα διακινείται σε πραγματικό χρόνο και θα αξιοποιείται από τις ρυθμιστικές αρχές, με αποτέλεσμα τη δημιουργία μιας αξιόπιστης και ευέλικτης αγοράς ηλεκτρικής ενέργειας. Τα καλώδια του ρεύματος πηγαίνουν παντού και αποτελούνται συνήθως από καλής ποιότητας χαλκό. Επίσης, οι μόνες συχνότητες που χρησιμοποιούνται είναι αυτές του ρεύματος, δηλαδή τα 50 και 60 Hz. Έτσι, η μετάδοση σημάτων πληροφορίας μέσω των γραμμών ηλεκτρικής ισχύος είναι απλή στη σύλληψή της. Τέλος, γίνεται ένας σχολιασμός σε διάφορα μοντέλα εξομοιώσεων σε Matlab για την συμπεριφορά των διαφόρων παραμέτρων που επηρεάζουν το BPL δίκτυο. / -
12

Συμπεριφορά έναντι κεραυνών γραμμών υψηλής τάσης / Behavior of high voltage transmission lines against lightning

Χατζηκαραγεωργίου, Πυθαγόρας 25 January 2012 (has links)
Στην παρούσα διπλωματική εργασία μελετάται η ικανότητα συμπεριφοράς γραμμών μεταφοράς υψηλής τάσης έναντι κεραυνών. Αρχικά γίνεται μια ιστορική αναδρομή για τον κεραυνό. Στη συνέχεια, εξετάζονται οι κεραυνοί και παρατίθενται μια ενδελεχής παρουσίαση των ειδών των κεραυνικών αλλά και των ατμοσφαιρικών εκκενώσεων, προχωρώντας μετά στην αναφορά των κύριων χαρακτηριστικών των κεραυνών, των αποτελεσμάτων τα οποία προκαλούν, αλλά και των παραμέτρων από τις οποίες εξαρτώνται και χαρακτηρίζονται. Έπειτα, γίνεται μια αναλυτική περιγραφή των γραμμών μεταφοράς, παρουσιάζοντας τις κατηγοριοποιήσεις στις οποίες υπόκεινται, με κύρια κριτήρια αυτών να είναι η ονομαστική τάση υπό την οποία είναι φορτισμένες, το μήκος αλλά και την ικανότητα τους στην μεταφορά ηλεκτρικής ενέργειας. Επίσης, γίνεται αναφορά στις καταπονήσεις τις οποίες δέχονται οι γραμμές αλλά και στην μόνωση, όπως και στα χαρακτηριστικά τους. Παρακάτω, βλέπουμε ποια είναι τα κύρια είδη σφαλμάτων στις εναέριες γραμμές μεταφοράς και από ποιες αιτίες αυτά προκαλούνται. Το επόμενο κεφάλαιο πραγματεύεται τη μόνωση των γραμμών αλλά και τα κεραυνικά πλήγματα, ενώ εξετάζονται οι μηχανισμοί που προκαλούν την παραγωγή υπερτάσεων στις γραμμές. Έπειτα, για το καθορισμό της θέσης του αγωγού προστασίας της γραμμής παρουσιάζονται οι μέθοδοι της μέγιστης γωνίας και η ηλεκτρογεωμετρική μέθοδος. Στο προτελευταίο κεφάλαιο , υπάρχει μια εκτενής αναφορά στο πρόγραμμα ATP-EMTP και τα στοιχεία του. Τέλος, παρουσιάζεται μια εξομοίωση μιας γραμμής μεταφοράς υψηλής τάσης με τη χρήση του συγκεκριμένου προγράμματος και κυρίως του γραφικού προεπεξεργαστή του , που είναι το πρόγραμμα ATPDraw. Η εξομοίωση αυτή έγινε για διαφορετικών εντάσεων κεραυνικά ρεύματα τα οποία πλήττουν τον αγωγό προστασίας της γραμμής, και μελετά τις παραγόμενες υπερτάσεις σε τέσσερα διαφορετικά σημεία αυτής και το βαθμό επικινδυνότητάς τους. / In this diploma thesis is studied the ability to conduct high voltage transmission lines against lightning. Initially, there is a little historical background to the lightning. Afterwards there is a study about lightning and it is provided a thorough presentation of the types of lightning and atmospheric discharges, moving afterwards to the reference of the main lightning features, the results that they rise, as well as the parameters that they depend on and described from. Next, a more detailed description of the transmission lines, showing the classifications in which they are subject to, with main criteria, the nominal voltage in which they are charged, the length, but also their ability of electricity transmission. Moreover, there is a reference to the stresses, in which the lines are subjected to, as well as their insulation level and their characteristics. Below, we can see what the main types of outages in air transmission lines are and which are the causes that generate them. The next chapter deals with the isolation of lines, as well as with lightning strokes and described the mechanisms which cause the overvoltages on transmission lines. Then, in order to determine the position of the line protection conductor , the maximum angle method as well as the electrogeometrical method are presented. The fifth chapter contains an extended reference to the ATP-EMTP program and its components. Finally, a simulation of a high voltage transmission line is represented, with the use of this program and mainly its graphic preprocessor, which is the program ATPDraw. This simulation has been done for different intensities of lightning currents, which strike at the protection conductor of the line,and it is also studying overvoltages at four different points and the risk rate.
13

Υπολογισμός υπερτάσεων λόγω κεραυνών σε συνδέσεις εναέριων γραμμών - υπόγειων καλωδίων

Δεληγιάννης, Αναστάσιος 19 July 2012 (has links)
Σκοπός της παρούσας διπλωματικής εργασίας είναι η μελέτη της συμπεριφοράς εναέριων γραμμών και υπόγειων καλωδίων μεταφοράς υψηλής τάσης έναντι κεραυνών. Για την εξυπηρέτηση του σκοπού αυτού, γίνεται προσομοίωση ενός υβριδικού δικτύου, αποτελούμενου τόσο από εναέριες γραμμές μεταφοράς όσο και από υπόγεια καλώδια, και μελέτη των μεταβατικών υπερτάσεων που εμφανίζονται σε αυτό λόγω κεραυνικών πληγμάτων σε έναν από τους αγωγούς προστασίας του τερματικού πυλώνα, όπου πραγματοποιείται η διασύνδεση εναέριας γραμμής-υπόγειου καλωδίου. Στο πρώτο κεφάλαιο παρατίθενται κάποια θεωρητικά στοιχεία σχετικά με τις ατμοσφαιρικές υπερτάσεις. Αναλύονται τα είδη των κεραυνών, οι βασικές παράμετροι και τα κύρια χαρακτηριστικά τους. Επιπλέον, περιγράφονται οι επιπτώσεις από κεραυνικά πλήγματα και ο τρόπος εύρεσης της συχνότητας με την οποία συμβαίνουν κεραυνοί ανά περιοχή. Στο δεύτερο κεφάλαιο γίνεται μία εισαγωγή στα Συστήματα Ηλεκτρικής Ενέργειας και αναπτύσσονται τα βασικά στοιχεία των εναέριων γραμμών και των υπόγειων καλωδίων μεταφοράς ηλεκτρικής ενέργειας. Επίσης, πραγματοποιείται μία σύγκριση αυτών των δύο τρόπων μεταφοράς ηλεκτρικής ενέργειας, παρουσιάζοντας τα θετικά και αρνητικά στοιχεία καθενός από αυτούς. Στο τρίτο κεφάλαιο εξετάζονται τα είδη σφαλμάτων και τα αίτια δημιουργίας αυτών στις γραμμές μεταφοράς ηλεκτρικής ενέργειας. Επιπλέον, δίνονται κάποια βασικά χαρακτηριστικά για την κυματομορφή του κεραυνικού ρεύματος. Στο τέταρτο κεφάλαιο αναλύεται η μόνωση και η προστασία τόσο των εναέριων γραμμών όσο και των υπόγειων καλωδίων έναντι κεραυνικών πληγμάτων. Εξετάζονται ακόμα οι μηχανισμοί που εγείρουν υπερτάσεις στη γραμμή μεταφοράς. Έπειτα, για τον καθορισμό της θέσης των αγωγών προστασίας της γραμμής, περιγράφονται οι μέθοδοι της μέγιστης γωνίας αλλά και η ηλεκτρογεωμετρική μέθοδος. Στο πέμπτο κεφάλαιο αναπτύσσονται τα επιμέρους στοιχεία του υπολογιστικού προγράμματος ATP-EMTP, το οποίο θα αποτελέσει το μέσο εξομοίωσης για την παρούσα εργασία. Αναφέρονται τα σημεία υπεροχής και η καταλληλότητά του για τέτοιου είδους αναλύσεις και παρουσιάζονται τα επιμέρους υποπρογράμματα από τα οποία αποτελείται. Ιδιαίτερη έμφαση δίνεται στο ATPDraw, το οποίο είναι το κύριο όργανο της εξομοίωσης. Στο έκτο κεφάλαιο περιγράφεται αναλυτικά το υβριδικό δίκτυο μεταφοράς υψηλής τάσης που χρησιμοποιείται στην εξομοίωση και αναλύονται τα στοιχεία που το αποτελούν, δηλαδή οι εναέριες γραμμές και τα υπόγεια καλώδια. Επιπλέον, παρουσιάζονται τα αποτελέσματα των εξομοιώσεων και οι γραφικές παραστάσεις των υπερτάσεων στα διάφορα σημεία του κυκλώματος, εξαιτίας κεραυνικών πληγμάτων, των οποίων το εύρος αυξάνει σε κάθε εξομοίωση. Στη συνέχεια ελέγχεται η επικινδυνότητα των υπερτάσεων που εγείρονται για τα διάφορα μεγέθη κεραυνικού ρεύματος και εάν ο εξοπλισμός σε διαφορετικά σημεία του δικτύου αντέχει τις υπερτάσεις αυτές ή καταστρέφεται. Από τα αποτελέσματα προκύπτει ότι επικίνδυνες υπερτάσεις παρατηρούνται σε τμήματα της εναέριας γραμμής μεταφοράς πλησίον του σημείου κεραυνικού πλήγματος. Αντίθετα, το υπόγειο τμήμα του δικτύου αποδεικνύεται πιο ανθεκτικό, καθώς δεν εγείρονται επικίνδυνες υπερτάσεις ακόμα και για πολύ υψηλό κεραυνικό ρεύμα. / The purpose of this diploma thesis is the study of the behavior of overhead transmission lines and underground transmission cables against lightning. In favor of this purpose, a simulation of a hybrid transmission network takes place, which is composed of both overhead lines and underground cables, in order to examine transient overvoltages. These overvoltages are raised due to a lightning that strikes the shield wire of the terminal tower, where the interconnection of overhead line to underground cable takes place. Chapter one presents the basic theory concerning atmospheric discharges. It describes the different types of lightning strikes, their parameters and basic characteristics. Furthermore, it analyzes the consequences of lightning and how to find the frequency that a lightning takes place in an area. At the second chapter there is an introduction in the systems of electric energy and a presentation of the basic characteristics of overhead lines and underground cables. In addition, there is a comparison between those two means of electricity transmission. Chapter three examines the types of errors and the causes of them at the electricity transmission lines. Moreover, it gives the basic parameters of the lightning current waveform. Chapter four analyzes the insulation and protection of both overhead lines and underground cables against lightning. It also examines the mechanisms that raise overvoltages at the transmission lines. Afterwards, there are described two methods on how to define the place of shield wires at a transmission line. Chapter five describes the ATP-EMTP simulation program, which is a specific software to simulate power systems. Its superiority for research like the present one is high lined and special emphasis is given to ATPDraw which is the main tool for the simulation. At chapter six there is a detailed analysis of the hybrid network used in this simulation and of its basic components, which are the overhead lines and the underground cables. Furthermore, there is a presentation of the results of the simulation and the graphs of the overvoltages at different spots of the network, due to lightning strikes. Afterwards, there is an evaluation of the risk of overvoltages that are raised for different lightning current sizes and if the equipment at different spots of the network sustains these overvoltages or it is destroyed. From the results, it is concluded that dangerous overvoltages are raised at sections of the overhead line near the lightning strike. On the contrary, the underground section of the network appears to be more resistant, as there are not raised dangerous overvoltages, even when the lightning current was too high.
14

Επαγόμενες υπερτάσεις σε υπέργειο αγωγό μεταφοράς φυσικού αερίου/πετρελαίου από κεραυνικό πλήγμα σε παρακείμενη γραμμή μεταφοράς υψηλής τάσης

Παπαγιάννης, Μάριος-Παναγιώτης 14 October 2013 (has links)
Τις τελευταίες δεκαετίες παρατηρείται σε παγκόσμιο επίπεδο τεράστια αύξηση των ενεργειακών απαιτήσεων για όλες τις κατηγορίες καταναλωτών. Η γιγάντωση της βιομηχανίας, η ανάπτυξη πρώην αναπτυσσόμενων χωρών με ραγδαίους ρυθμούς όπως η Κίνα, η Ινδία κλπ, η γενικότερη άνοδος του βιοτικού επιπέδου σε παγκόσμια κλίμακα, αλλά και η αύξηση του παγκόσμιου πληθυσμού, έχουν οδηγήσει σε εκθετική αύξηση των ενεργειακών ανάγκών του. Για την κάλυψη των αναγκών αυτών, μεγάλα έργα έχουν παραγματοποιηθεί με σκοπό την αποτελεσματικότερη εκμετάλλευση των καυσίμων και λοιπών ενεργειακών πόρων, αλλά και την γρηγορότερη και ασφαλέστερη μεταφορά τους από τα σημεία εξόρυξης και επεξεργασίας, στα κέντρα κατανάλωσης. Στο ευρύτερο αυτό πλαίσιο, η βιομηχανία της κατασκευής σωληναγωγών μεταφοράς υδρογονανθράκων γνωρίζει τεράστια ανάπτυξη τα τελευταία είκοσι χρόνια. Παράλληλα, την ίδια αν όχι μεγαλύτερη ανάπτυξη γνωρίζει και η βιομηχανία παραγωγής και μεταφοράς ηλεκτρικής ενέργειας. Για πολλούς λόγους η εξέλιξη των δύο αυτών βιομηχανικών τομέων είναι συνδεδεμένη και ακολουθεί κοινούς ενεργειακούς δρόμους. Έτσι, η επιλογή κοινών «οδών» διάβασης των υποδομών της βιομηχανίας ηλεκτρισμού και της πετρελαιοβιομηχανίας αποτελεί σήμερα πολύ συνηθισμένη πρακτική-αν όχι τον κανόνα. Κατά συνέπεια, οι περιπτώσεις παραλλήλισμού, έμμεσης προσέγγισης και διασταύρωσης γραμμών μεταφοράς υψηλής και υπερυψηλής τάσης, με αγωγούς μεταφοράς φυσικού αερίου ή πετρελαίου –υπέργειους και υπόγειους- είναι συχνή. Στις περιπτώσεις αυτές, η ηλεκτρομαγνητική επίδραση πάνω στον αγωγό μεταφοράς από την γραμμή Υ/Τ (ή ΥΥ/Τ) είναι ιδιαίτερα σημαντική. Σκοπός της παρούσας διπλωματικής εργασίας είναι η μελέτη αυτής ακριβώς της επίδρασης μιας γραμμής υψηλής τάσης πάνω σε έναν παρακείμενο υπέργειο αγωγό μεταφοράς υδρογονανθράκων, κατά την διάρκεια ενός κεραυνικού πλήγματος επί της γραμμής. Αρχικά, στα πρώτα έξι κεφάλαια έγινε μια παράθεση πληροφοριών και θεωρητική προσέγγιση όλων των επιμέρους τμημάτων που συνθέτουν τη συνολική διάταξη της μελέτης. Στο πρώτο κεφάλαιο δόθηκαν γενικές πληροφορίες για τα διάφορα είδη υπερτάσεων και την κατηγοριοποίησή τους. Στο δεύτερο κεφάλαιο διατυπώθηκαν τα βασικά χαρακτηριστικά του φαινομένου του κεραυνού, αποπειράθηκε η προσέγγιση της συμπεριφοράς του φυσικού αυτού φαινομένου, καθώς και διαπιστώθηκαν οι συνέπειες της ενέργειάς του. Στο τρίτο κεφάλαιο, έγινε μία συμπυκνωμένη παρουσίαση της θεωρητικής προσέγγισης των γραμμών μεταφοράς και δόθηκαν βασικά στοιχεία της θεωρίας για την μοντελόποίησή τους. Στο τέταρτο κεφάλαιο, παρουσιάστηκαν τα βασικά θεωρητικά στοιχεία για την μοντελοποίηση των πυλώνων και την επίδραση των κεραυνικών πληγμάτων σε αυτούς. Στο πέμπτο κεφάλαιο, δόθηκαν γενικές πληροφορίες για την ιστορία, την χρησιμότητα, την κατασκευή και τον έλεγχο των σωληναγωγών μεταφοράς αγαθών, που παίζουν πολύ σημαντικό ρόλο πρωτίστως στην παγκόσμια βιομηχανία πετρελαίου και ενέργειας. Στο έκτο κεφάλαιο, πραγματοποιήθηκε μια παρουσίαση των βασικών δομών και δυνατοτήτων του προγράμματος που χρησιμοποιήθηκε για την εκπόνηση της διπλωματικής αυτής εργασίας, του ATP-EMTP. Το κεφάλαιο επτά που ακολούθησε, αποτελεί τον πυρήνα αυτής της διπλωματικής εργασίας, καθώς σε αυτό περιγράφηκαν αναλυτικά τα μοντέλα που χρησιμοποιήθηκαν για την εξομοίωση όλων των συνιστωσών της διάταξης, δόθηκαν αναλυτικές πληροφορίες για τον τρόπο υπολογισμού των μοντέλων αυτών αλλά και για την ενσωμάτωσή τους στο πρόγραμμα ATP-Draw του EMTP. Πιο συγκεκριμένα στο έβδομο κεφάλαιο περιέχονται τα εξής: Πρωταρχικά, δόθηκαν τα χαρακτηριστικά της γεννήτριας Heidler που εξομοίωσε το σήμα του κεραυνού, μαζί με όλες τις παραμέτρους για την ενσωμάτωση του μοντέλου στο πρόγραμμα. Ακολούθως, έγινε αναλυτική παρουσίαση της γραμμής μεταφοράς ηλεκτρικής ενέργειας των 400kV διπλού κυκλώματος, του ελληνικού ΣΗΕ. Υπολογίστηκαν όλα τα χαρακτηριστικά της γραμμής, συμπεριλαμβανομένου των μέσων υψών και των εμπεδήσεων προσαρμογής που της αντιστοιχούν, και παρουσιάστηκε αναλυτικά η ενσωμάτωση όλων των παραμέτρων της γραμμής στο πρόγραμμα της εξομοίωσης. Έπειτα, έγινε πλήρης ανάλυση του χρησιμοποιηθέντος μοντέλου για την εξομοίωση των πυλώνων της γραμμής και παρατέθηκαν τα χαρακτηριστικά που επιβάλλεται αυτό να πληροί. Ακόμη, εξετάστηκαν οι πιθανές προσεγγίσεις για την μοντελοποίηση της γείωσης των πυλώνων και επιλέχθηκε η χρήση της γείωσης ωμικού χαρακτήρα ως πιο γενικής. Τόσο για το μοντέλο του πυλώνα, όσο και για εκείνο της γείωσής του, δόθηκε με λεπτομέρια η εικόνα ενσωμάτωσής τους στο πρόγραμμα εξομοίωσης. Μετέπειτα, παρουσιάστηκε το μοντέλο εξομοίωσης του υπέργειου αγωγού μεταφοράς υδρογονανθράκων (φυσικού αερίου/πετρελαίου), υπολογίστηκαν οι ηλέκτρικές του παράμετροι και αποτυπώθηκε η ενσωμάτωσή τους στο EMTP. Αμέσως μετά εξετάστηκε ίσως το πιό σημαντικό και δύσκολο κομμάτι της παρούσας διπλωματικής εργασίας, που δεν ήταν άλλο από την εξακρίβωση της αλληλεπίδρασης μεταξύ της γραμμής των 400kV και του παρακείμενου αγωγού μεταφοράς υδρογονανθράκων. Στο κομμάτι αυτό, διαπιστώθηκε η ύπαρξη των εξής τριών συνιστωσών αλληλεπίδρασης: χωρητική, επαγωγική και ωμική. Και για τις τρείς αυτές συνιστώσες της αλληλεπίδρασης του συστήματος γραμμής-αγωγού ακολούθησε εις βάθος ανάλυση του τρόπου υπολογισμού τους, των παραγόμενων αποτελεσμάτων και της ενσωμάτωσής τους στη διάταξη της εξομοίωσης. Επιπρόσθετα, στο σημείο αυτό δόθηκαν και γενικότερες αριθμητικές πληροφορίες που αφορούν το υπο εξομοίωση σύστημα, συμπεριλαμβανομένων των επιλογών του ερευνητή σχετικά με τις προσεγγίσεις της εξομοίωσης. Κλείνοντας το κεφάλαιο επτά, παρουσιάστηκε με σαφήνεια ο τρόπος ενσωμάτωσης στο πρόγραμμα των τριών συνιστωσών αλληλεπίδρασης του συστήματος γραμμής-αγωγού, μία προς μία, αλλά και συνολικά. Η συνολική αυτή αποτύπωση εμφάνισε και την δομική μονάδα του κυκλωματικού ισοδύναμου της διάταξης, η οποία αποτέλεσε τον θεμέλιο λίθο της όλης εξομοίωσης. Τέλος, η παρούσα διπλωματική εργασία ολοκληρώνεται με το όγδοο κεφάλαιο. Στο κεφάλαιο αυτό γίνεται παράθεση των αποτελεσμάτων της έρευνας για την επαγόμενη τάση πάνω σε έναν αγωγό μεταφοράς φυσικού αερίου/πετρελαίου από παρακείμενη γραμμή μεταφοράς Υψηλής Τάσης, η οποία υφίσταται κεραυνικό πλήγμα. Η παρουσίαση των αποτελεσμάτων περιλαμβάνει όλα τα αριθμητικά αποτελέσματα αλλά και τις αντίστοιχες γραφικές παραστάσεις για τις επαγόμενες τάσεις, πάνω στον αγωγό μεταφοράς υδρογονανθράκων, αλλά και στους πυλώνες και τις φάσεις της γραμμής που δέχεται το κεραυνικό πλήγμα. Κλείνοντας το τελευταίο κεφάλαιο, διατυπώνεται σειρά παρατηρήσεων επί των αποτελεσμάτων και γίνεται απόπειρα εξαγωγής κάποιων συμπερασμάτων από την όλη μελέτη. Συγκεκριμένα, διαπιστώθηκε πως ο παραλληλισμός γραμμών μεταφοράς ηλεκτρικής ενέργειας Υ/Τ και αγωγών μεταφοράς υδρογονανθράκων δημιουργεί ένα σύστημα με έντονη αλληλεπίδραση κάτω από προϋποθέσεις. Οι τάσεις και τα ρεύματα που υφίστανται επί της γραμμής, ειδικά σε περιπτώσεις έντονων σφαλμάτων και κεραυνικών πληγμάτων, έχουν ως αποτέλεσμα την ηλεκτρομαγνητική και ηλεκτροστατική σύζευξη γραμμής και αγωγού. Προϊόν της σύζευξης αυτής είναι η επαγόμενη τάση στον αγωγό μεταφοράς υδρογονανθράκων, η οποία σε κατάλληλες συνθήκες μπορεί να καταστεί επικίνδυνη, τόσο για τον άνθρωπο, όσο και για την ασφάλεια του ίδιου του αγωγού. / Over the last few decades, a huge growth on energy demands for all consuming categories is observed in a global scale. The giant growth of overall global industry, the development of former developing countries such as China, and India, etc at a rapid pace, the increase of the planet’s total population and its overall living standard has led to an exponential growth of the planet’s energy needs. To satisfy those energy needs, huge projects have been realised worldwide, in order to maximise the effisient use of fuel and other natural energy resources, as well as their fast and secure transport from their mining and refinery points to the big consumption centres. Within this framework, the gas/petroleum pipeline industry has flourished for the past twenty years. At the same time, the electrical power industry has known similar, if not greater, growth. For a variety of reasons, the development of those two industries is significantly connected and they are following, systematically common energy routes. As a result, the selection of comon right-of-ways for the infrastructure of both the gas/oil pipeline and power industry is a common practise-if not the rule. Therefore, the situations of parallelism, oblique approach and crossing between High Voltage (or even Ultra High Voltage) transmission lines and gas/petroleum pipelines –either above or underground– have quite frequently happened. In those cases, the electromagnetic influence on the oil/gas pipeline near the transmission line becomes increasingly significant. The purpose of this diploma thesis is the study of the above stated effect of a High Voltage transmission line on a nearby above ground gas/oil pipeline, under lightning conditions affecting the transmission line itself. Initially, during the first six chapters a theoretical approach was attempted and information was displayed concerning each basic part, that the total –under study– layout consists of. In the first chapter, general information for the various categories of overvoltages were given. In the second chapter, the basic characteristics of lightning were presented, its behaviour as a natural phenomenon was approched and its disastrous effects were established. During the third chapter, a theoretical approach of transmission lines was attempted and basic elements of transmission line modeling theory were given. In chapter four, basic theoretical data concerning the modeling of transmission line towers were presented and the effect of lightning on them was examined. In the fifth chapter, general information about the history, use, construction and control of pipelines were presented. The vital role this infrastructure plays in the global gas/oil and power industry was ascertained. During the sixth chapter, basic structures and key sub-programs of the ATP-EMTP (ElectoMagnetic Transient Program) were presented, along with the capabilities of this powerful software tool, that was used to perform the simulations required for this diploma thesis. Chapter seven that followed next, represents the very core of this thesis. In that chapter, a detailed description of the models used to simulate the transmission line-oil/gas pipeline layout, was presented and specific information concerning the calculations of model parameters and their implementation in ATP-Draw of EMTP was given. More specificly, the seventh chapter of the thesis contains the following: First of all, the characteristics of the Heidler generator -used to simulate the lightning strike- were given, along with all the respective parameters for its implementation in the EMTP. After that, a detailed presentation of the double-circuit 400kV transmission power line of the Greek Power Network was made. All its parameters were calculated, including average heights and matching impdendances, and their implementation in the EMTP was specified. Next, the line’s tower model that was used in the simulation was analysed and its specific critiria that needed to be met were indicated. Different possible approaches for the modeling of the tower’s footing groung were also examined, resulting in the selection of the resistive grounding electrode as the most general case. For both the tower model and the footing resistance, the implementation in the EMTP was made clear. Afterwards, the simulation model of the aboveground gas/oil pipeline was presented, its parameters were calculated and their implementation in the EMTP was depicted. Right after that, the most significant and at the same time difficult part of this study was examined: the verification of the coupling between the 400kV transmission line and the nearby gas/oil pipeline. In this part of the study, the existance of the following three coupling types was identified: capacitive, inductive and resistive coupling. For all three types of coupling between the transmission line and the pipeline, an in-depth calculative analysis was carried out, followed by representation of the produced results and their implementation in the program. Furthermore, general numerical data concerning the simulation was presented at this point, along with the researcher’s selected approximations for modeling the transmission line-gas/oil pipeline layout. Closing this chapter, the implementation in the EMTP of all three types of coupling was illustrated, both in overall and one-by-one. This overall illustration of the layout’s coupling, revealed the basic structure block of the simulation. This diploma thesis is completed in the eighth and final chapter. In that part of the study, the final simulation results are presented, concerning the induced voltage on the gas/oil pipeline from the nearby transmission power line that suffers a lightning strike. This presentation includes all numerical data and respective graphs (graphic displays) of the induced voltages on the pipeline itself, as well as the towers and the 6 phases of the transmission line. Winding up the last chapter, a series of observations on the results is made, and an attempt to reach some conclusions based on the specific study is carried out. More specifically, it was established that situations of parallelism, oblique approach and crossing between High Voltage (or even Ultra High Voltage) transmission lines and gas/petroleum pipelines –either above or underground– can create a system prone to intense coupling under certain circumstances. Strong currents and voltages circulating on the transmission line, especially during faulty and lightning conditions, result in the electromagnetic and electrostatic coupling between the line and the nearby gas/oil pipeline. Direct result of this coupling is the induced voltage upon the gas/oil pipeline, which can -under proper conditions- become a hazard for both the human factor and the safety of the pipeline itself.
15

Μελέτη της λειτουργικότητας του κροσσωτού επιθηλίου του βλεννογόνου του ιγμόρειου άντρου μετά από έκχυση ραδιοϊσοτόπου 99Tcm-MAA σε ασθενείς με χρόνια ιγμορίτιδα και συσχέτιση με ευρήματα αξονικής τομογραφίας

Αθανασόπουλος, Ιωάννης 26 January 2009 (has links)
Η ρινοκολπίτιδα οδηγεί τους ασθενείς σε συχνές ιατρικές επισκέψεις. Συντελεί σημαντικά στις δαπάνες για την υγεία, τόσο στις άμεσες λόγω ιατρικών επισκέψεων και φαρμακευτικής αγωγής, όσο και στις έμμεσες που συνδέονται με την απουσία από την εργασία, καθώς και με μια γενικότερη πτώση της παραγωγικότητας που οφείλεται σε μείωση της ποιότητας ζωής των ατόμων που πάσχουν. Η βαθύτερη κατανόηση της παθογένειας και αιτιολογίας της χρόνιας ρινοκολπίτιδας είναι απαραίτητη προκειμένου να αναπτυχθούν αποτελεσματικές θεραπείες. Το ιγμόρειο άντρο αποτελεί το συχνότερο κλινικό εντοπισμό της και χώρο εύκολα προσπελάσιμο για την μελέτη της παθογένειας των παθήσεων των παραρρινίων κόλπων. Η καταστροφή του κροσσωτού επιθήλιου ή η δυσλειτουργία των κροσσών του βλεννογόνου της μύτης και των παραρρινίων κόλπων επηρεάζουν αρνητικά την κάθαρση του βλεννοκροσσωτού επιθηλίου, η οποία αποτελεί έναν από τους μηχανισμούς που διαταράσσεται σε ρινοκολπίτιδα. Η ταχύτητα μεταφοράς του βλεννοκροσσωτού επιθηλίου (mucociliary transport velocity – MTV) που εκτιμάται με το ρινοσπινθηρογράφημα θεωρείται μια αξιόπιστη μέτρηση της κάθαρσης του βλεννοκροσσωτού επιθηλίου. Σχεδιάσαμε την παρούσα μελέτη με σκοπό τη διερεύνηση, μέσω του ρινοσπινθηρογραφήματος, της κάθαρσης του βλεννοκροσσωτού επιθηλίου σε ασθενείς με χρόνια ιγμορίτιδα που αντιμετωπίστηκαν συντηρητικά ή χειρουργικά. Επίσης μελετήσαμε την συσχέτιση της με ευρήματα από την αξονική τομογραφία καθώς και με τη βαρύτητα των συμπτωμάτων του ασθενούς. / Rhinosinusitis leads patients to frequent visits to medical doctors. It greatly contributes to healthcare expenses, directly due to medical visits and medication, as well as indirectly due to the subsequent absence from work and a productivity loss due to patients’ life quality deterioration. The deeper understanding of the cause and pathogenesis of the chronic rhinosinusitis is essential to the development of an effective treatment. The maxillary sinus is the most frequent location and it is easily accessible for the study of the pathogenesis of facial sinuses diseases. The ciliary epithelium destruction or the dysfunction of the nose mucosa’s cilia, negatively influences the mucociliary epithelium clearance, which constitutes one of the mechanisms disrupted in a rhinosinusitis. The Mucociliary Transport Velocity (MTV) which is estimated by the use of rhinoscintigraphy, is concerned a reliable measurement of the clearance of the mucociliary epithelium. We have designed the current study, in order to investigate, through the rhinoscintigraphy, the clearance of the mucociliary epithelium in patients with chronic maxillary sinusitis who were treated conservatively or surgically. Also, we studied its correlation with the CT findings, as well as with the quality of patients’ life.
16

Έκφραση και χαρακτηρισμός ανασυνδυασμένων πρωτεϊνών μεταφοράς χαλκού για τη μελέτη της συνεργικής τους δράσης κατά το τελευταίο στάδιο της αναπνευστικής αλυσίδας του μιτοχονδρίου / Expression and characterization of recombinant copper chaperones for the study of their synergic action in the final step of mitochondrial respiratory chain.

Γκαζώνης, Πέτρος 09 February 2009 (has links)
Ο ρόλος του χαλκού είναι πολύ σημαντικός για τη σωστή λειτουργία της κυτοχρωμικής c οξειδάσης (CcO), και συνεπώς για την κυτταρική αναπνοή στους ευκαρυωτικούς και προκαρυωτικούς οργανισμούς. Η συγκρότηση της CcO στον ενδομεμβρανικό μιτοχονδριακό χώρο είναι μια πολύπλοκη διαδικασία, εξαρτώμενη από πλήθος συνεργών πρωτεϊνών, υπεύθυνων για τη λειτουργική αναδίπλωση των υπομονάδων του ενζύμου και τη μεταφορά αίμης και ιόντων Cu σε αυτές. Ενώ οι πρωτεΐνες που ενέχονται στη διαδικασία είναι μάλλον γνωστές, οι μηχανισμοί μεταφοράς και ενσωμάτωσης των μεταλλικών ιόντων στα δυο ενεργά κέντρα της CcO, CuA και CuB, παραμένουν ανεξερεύνητοι. Το CuA κέντρο είναι ένα διπυρηνικό κέντρο χαλκού, του οποίου ο ρόλος εντοπίζεται στη μεταφορά e- από το κυτόχρωμα c στο καταλυτικό κέντρο CuB της CcO. Η σωστή συγκρότηση του CuA κέντρου είναι κρίσιμης σημασίας για την καταλυτική δράση του ενζύμου. Αρκετές πρωτεΐνες έχουν χαρακτηριστεί σαν ενεργοί παράγοντες στη μεταφορά ιόντων Cu στο CuA κέντρο, ο ακριβής, ωστόσο, μοριακός μηχανισμός και ρόλος της κάθε πρωτεΐνης είναι άγνωστος. Στους προκαρυωτικούς οργανισμούς, δυο οικογένειες πρωτεϊνών έχουν προταθεί για την εμπλοκή τους στη συγκρότηση του CuA. Η πρώτη περιλαμβάνει πρωτεΐνες που δεσμεύουν ιόντα Cu1+ με ένα συντηρημένο μοτίβο δέσμευσης H(M)x10Mx21HxM (υποθετικές πρωτεΐνες Hyp1) ενώ η δεύτερη περιλαμβάνει τις πρωτεΐνες της οικογένειας Sco, των οποίων ο ρόλος στον μηχανισμό του CuA κέντρου σαν θειορεδοξίνες ή χαλκομεταφορείς, παραμένει ασαφής. Στην παρούσα εργασία αποδείχθηκε ότι μια νέα περιπλασματική πρωτεΐνη (TtHyp1 ή PCuAC) εισάγει επιλεκτικά ιόντα Cu1+ στην Cox2 υπομονάδα της ba3-CcO του Thermus thermophilus προς σχηματισμό του φυσιολογικού διπυρηνικού TtCuA κέντρου, καθώς και ότι η Sco πρωτεΐνη του συγκεκριμένου οργανισμού (TtSco1) δεν μεταφέρει μεταλλικά ιόντα στο CuA, αλλά δρα σαν θειο-δισουλφιδική αναγωγάση ρυθμίζοντας τη σωστή οξειδωτική κατάσταση των κυστεϊνικών καταλοίπων του CuA. Οι πρωτεΐνες PCuAC, TtSco1 και TtCuA εκφράστηκαν, απομονώθηκαν και μελετήθηκαν τα βιοχημικά χαρακτηριστικά τους, η ικανότητα δέσμευσης μεταλλικών ιόντων και οι μεταξύ τους αλληλεπιδράσεις. Επιπλέον η PCuAC χαρακτηρίστηκε δομικά με φασματοσκοπία NMR στην απο και Cu(I) μορφή της. Ο ρόλος των προκαρυωτικών Sco διερευνήθηκε περαιτέρω με μελέτες γονιδιακής ανάλυσης και την έκφραση και τον προκαταρκτικό χαρακτηρισμό μιας νέας πρωτεΐνης, PpSco1/cytc της Pseudomonas putida, πρωτεΐνης αποτελούμενης από δυο επικράτειες, Sco1 και cytc, συνδέοντας το ρόλο των Sco πρωτεϊνών με τη θεωρια περί θειρεδοξινικής τους δράσης. Καινοτομία στην παρούσα εργασία αποτέλεσε η μεθοδολογική προσέγγιση της πολλαπλής κλωνοποίησης των γονιδίων-στόχων με μια νέα τεχνολογία κλωνοποίησης (Gateway) συνδυασμένης με τοποειδική ένθεση σε πολλαπλούς πλασμιδιακούς φορείς και η ανάπτυξη high throughput τεχνικών για πολλαπλές δοκιμές έκφρασης – απομόνωσης. Η συγκεκριμένη μελέτη παρέχει νέα δεδομένα για το μηχανισμό τη συγκρότησης του CuA κέντρου της προκαρυωτικής CcO, υποστηρίζοντας ένα νέο μοντέλο για τη συγκεκριμένη διαδικασία και παράλληλα συνδράμει στην αποκρυπτογράφηση του πολύπλοκου ρόλου των Sco πρωτεϊνών. / Copper is essential for the correct assembly and function of the cytochrome c oxidase (CcO), thus for the efficient cellular respiration in both eukaryotes and prokaryotes. CcO assembly in the inner mitochondrial membrane space is a multi complicated procedure, depended on a number of co-factors and their synergic action. These co-factors are proteins commissioned with the correct folding of the enzyme subunits and the transport/incorporation of heme moieties and Cu ions to them. While the proteins involved in this multistep procedure are rather known, the mechanisms of metal ion delivery and incorporation within the two active centers of CcO, CuA and CuB, still remain uncharted. The CuA center is a binuclear copper center, whose part in the respiratory chain is spoted in electron transport from the active cytochrome c to the catalytic CuB center of CcO. Efficient CuA assembly is crucial for the catalytic action of the entire enzyme. Several proteins have been characterized as essential factors for the transport of Cu ions to the CuA center; however their exact molecular mechanism of action still remains obscure. In prokaryotes, two protein families have been suggested to be involved in the CuA assembly. The first includes proteins that bind Cu1+ ions through a potential conserved motif H(M)x10Mx21HxM (hypothetical proteins, Hyp1), while the second includes proteins of the Sco family, whose exact role in CuA assembly as thioredoxins or copper chaperones is widely debated. In this work, it is propesed that a new periplasmic protein (TtHyp1 or PCuAC) selectively inserts Cu1+ ions in the Cox2 subunit of the ba3-CcO of Thermus thermophilus resulting the formation of the physiological binuclear TtCuA center, as well as that the Sco protein of the organism (TtSco1) is not able to transfer metal ions to the CuA center; instead it acts rather like a thio-disulfide reductase adjusting the proper redox state of the CuA cysteine residues. Proteins PCuAC, TtSco1 and TtCuA were over-expressed, purified and subjected to biochemical characterization, while their Cu binding capability and their inter se interactions were studied through NMR and UV spectroscopy. In addition, PCuAC was structurally characterized through NMR in its apo and Cu(I) form. The role of Sco proteins was further investigated through genome based analysis and the expression and biochemical characterization of a new protein, PpSco1/cytc from Pseudomonas putida, a unique bacterial protein consisted on two domains, a Sco1 and a cytc domain, presumptively connecting the role of Sco proteins with the suggested theory of thioredoxin action. A novelty in this work was the methodological aspect of the multiple cloning of the target genes with a new cloning technology (Gateway) combined with site specific recombination into multiple expression plasmid vectors and the development of a high throughput technique for parallel expression/purification tests. The infra work provides new insights to the CuA center assembly molecular mechanism of the prokaryotic CcO, supporting a new model for the particular procedure and also subscripts for the decipherment of the complicated role of Sco proteins.
17

Κλωνοποίηση του γονιδίου της geminin του ποντικού και δημιουργία πλασμιδιακού / Cloning of geminin

Κοταντάκη, Πανωραία 29 June 2007 (has links)
Η geminin είναι ένα σχετικά καινούριο μόριο το οποίο διαθέτει καίριο ρόλο κατά την ανάπτυξη και την διαφοροποίηση, εξαιτίας του νευροποιητικού δυναμικού της, της ικανότητάς της να αλληλεπιδρά με μέλη των Hox και polycomb πρωτεϊνών, καθώς επίσης και να δρα σαν ρυθμιστής του κυτταρικού κύκλου, λειτουργώντας ως αναστολέας του παράγοντα αδειοδότησης της αντιγραφής του DNA, CDT1. Στα πλαίσια της εργασίας αυτής, κλωνοποιήσαμε το γονίδιο της geminin στο ποντίκι το οποίο αποτελείται από 7 εξώνια και καλύπτει μία περιοχή γύρω στα 10Kb. Σχεδιάσαμε και κλωνοποιήσαμε ένα πλασμιδιακό όχημα στόχευσης για το γονίδιο της mgeminin και εισήγαμε 3 θέσεις loxP στο γενωμικό locus αυτής, με σκοπό να δημιουργήσουμε υπό συνθήκη ελλειμματικούς ποντικούς για το γονίδιό της. Χρησιμοποιώντας το συγκεκριμένο φορέα στόχευσης αδρανοποιήσαμε το γονίδιο της Geminin σε pc3 (protamine Cre 3) πολυδύναμα κύτταρα ποντικού, δημιουργώντας ετερόζυγους ES κλώνους που φέρουν το «floxed» αλληλόμορφο, καθώς επίσης και το αλληλόμορφο αγρίου τύπου. Το μεταλλαγμένο αλληλόμορφο ελέγχθηκε τόσο με PCR όσο και με ανάλυση κατά Southern για την ορθότητα του ομόλογου ανασυνδυασμού. Ταυτοποιήσαμε 15 ορθά ανασυνδυασμένους ES κλώνους, οι οποίοι μπορούν να χρησιμοποιηθούν για τη δημιουργία υπό συνθήκη knockout ποντικών για το γονίδιο της geminin, μετά από έγχυση σε B6 βλαστοκύστεις και επακόλουθη μεταφορά αυτών σε θετές μητέρες. / Geminin is a novel bifunctional molecule with a pivotal role in the processes of differentiation and cell cycle regulation, due to its neuralizing potential, its ability to interact through Hox and polycomb group members, as well as in the inhibition of cell cycle progression through protein-protein interactions with the licensing factor Cdt1. We have cloned the mouse Geminin gene, which consists of 7 exons and spans approximately a region of 10Kb. We have generated a vector and introduced 3 loxP sites in the Geminin locus, in order to create conditional knockout mice. Using this knockout construct we inactivated the geminin locus in pc3 mouse embryonic stem cells, creating heterozygous ES clones, carrying a “floxed” and a “WT” allele for geminin. The mutant allele in the targeted ES cells has been verified with Southern blotting and PCR for the correct homologous recombination events. We identified 15 correctly targeted ES clones, which can be used for the generation of conditional geminin knockout mice, upon injection into B6 blastocysts and subsequent transfer to foster mothers.
18

Συμπεριφορά απαγωγέων υπέρτασης σε γραμμές μεταφοράς σε πλήγματα κεραυνών

Πανούση, Αικατερίνη 15 April 2013 (has links)
Σκοπός της εργασίας είναι η μελέτη της συμπεριφοράς απαγωγέων υπέρτασης στις γραμμές μεταφοράς υψηλής τάσης όταν αυτές καταπονούνται από κεραυνικά πλήγματα. Γίνεται μοντελοποίηση πραγματικών πυλώνων και γραμμών του Ελληνικού συστήματος μεταφοράς, καθώς και αλεξικέραυνων, προσομοίωσή τους στο πρόγραμμα ATP/EMTP και στη συνέχεια μελέτη των υπερτάσεων που εμφανίζονται κατά τη διάρκεια κεραυνικών πληγμάτων πάνω στους αγωγούς προστασίας. / The purpose of this thesis is the study of the behavior of surge arresters on high voltage transmission lines when they are strained by lightning strikes. Steel towers and transmission lines used in the Greek Transmission System and also surge arresters are simulated with ATP/EMTP and the overvoltages that occur during lightning strikes on the shielding wires are studied.
19

Μελέτη των συνθηκών ανοδίωσης για την παραγωγή μεμβρανών πορώδους αλουμίνας με ελεγχόμενα χαρακτηριστικά

Χριστουλάκη, Αναστασία 06 November 2014 (has links)
Στην παρούσα εργασία μελετάται πειραματικά η ανάπτυξη μεμβρανών πορώδους αλουμίνας με ελεγχόμενο πάχος, διάμετρο πόρου, σε ηλεκτρολύτη οξαλικού οξέος συγκεντρώσεως 0.3Μ με εφαρμοζόμενη τάση 40V και 50V. Για την κατανόηση του μηχανισμού της δημιουργίας των μεμβρανών πορώδους αλουμίνας γίνεται μια βιβλιογραφική παρουσίαση των μοντέλων ανάπτυξης της. Από τα πειράματα προκύπτει ότι ο ρυθμός ανάπτυξης του πάχους της μεμβράνης ακολουθεί τον νόμο του Faraday με απόδοση που εξαρτάται από την τάση ανοδίωσης. Τέλος υπολογίζεται η ενέργεια ενεργοποίησης για την αντίδραση του σχηματισμού της πορώδους αλουμίνας. Η ενέργεια ενεργοποίησης που αφορά την αντίδραση του αλουμινίου με τον ηλεκτρολύτη. / Ιn the present study, the synthesis of porous alumina membranes with controlled thickness and pore diameter is investigated. More specifically, the experimental condition under study was oxalic acid 0.3M under an applied voltage of 40V and 50V. In order to understand the growth mechanism of the porous alumina membrane formation, a bibliographic view of the growth models is presented. The experiments result in the conclusion that the thickness growth rate of the porous alumina membrane obeys the Faraday law for electrolysis with an efficiency being dependent on the anodization applied voltage. Finally, the activation energy for the porous alumina formation concerning the reaction of aluminum with the electrolyte, is calculated.
20

Μοντελοποίηση μονωτήρων υψηλής τάσης

Νταλούκας, Απόστολος 30 December 2014 (has links)
Σκοπόςτης παρούσας εργασίαςείναι αρχικά η δημιουργία ενός μοντέλου με τα χαρακτηριστικά ενός μονωτήρα υψηλής τάσης.Το μοντέλο αυτό θα ενσωματωθεί στο μοντέλο μιας γραμμής υψηλής τάσης διπλού κυκλώματος των 400kV, για να υπολογιστούν οι επαγόμενες υπερτάσεις σε παρακείμενο υπέργειο αγωγό μεταφοράς υδρογονανθράκων. Τα παραπάνω επιτυγχάνονταιμε τη μοντελοποίηση πραγματικών πυλώνων και γραμμών του Ελληνικού συστήματος μεταφοράς καθώς και υπέργειου αγωγού υδρογονανθράκων.Η εξομοίωση υλοποιείται μέσω του προγράμματος ATP-EMTP. Για τον σχεδιασμό του μοντέλου του μονωτήρα χρησιμοποιήθηκε το μοντέλοVolt-TimeCurve. Επίσης χρησιμοποιήθηκαν δύο τύποι κεραυνού για τις προσομοιώσεις, για γρήγορο και αργό σήμα, με τιμές ρεύματος 100kA. Για το γρήγορο, οι τιμές χρόνων μετώπου και ουράς 1.2/50μs και για το αργό σήμα 10/350μs. Σε αυτή τη διπλωματική εργασία υπάρχουν 8 κεφάλαια. Στα πρώτα 5 κεφάλαια έγινε μια παράθεση πληροφοριών και θεωρητική προσέγγιση όλων των επιμέρους τμημάτων που συνθέτουν τη συνολική διάταξη της μελέτης. Στο 5ο κεφάλαιο γίνεται λεπτομερής αναφοράστο πρόγραμμα ATP-EMTP στο οποίο πραγματοποιήθηκε η προσομοίωση.Στο 6o κεφάλαιο γίνεται η μοντελοποίηση όλων των στοιχείων της διάταξης και η ενσωμάτωσή τους στοATP-EMTP. Στο 7ο κεφάλαιο γίνεται παρουσίαση του μοντέλου του μονωτήρα που αναπτύχθηκε και στο 8ο κεφάλαιο γίνεται παρουσίαση των αποτελεσμάτων της προσομοίωσης και εξάγονται κάποια συμπεράσματα σχετικά με τη διάταξη. / The purpose of this paper is , at first, to create a model with the features of a high voltage insulator. This model will be incorporated into the model of a high-voltage line double circuit 400kV, to calculate the induced transients in adjacent aboveground pipeline hydrocarbons. These goals are achieved by modeling real pillars and lines of Greek transport system and overground pipeline hydrocarbons. The simulation is implemented through the ATP-EMTP. The model Volt-Time Curve is used for the modeling of the insulator. Also, two types of lightning are used for the simulations, for fast and slow signal, with current values 100kA. For fast signal, the prices of front and tail time are 1.2 / 50ms and for slow signal 10 / 350ms. In this thesis there are 8 chapters. In the first five chapters was a quote and information theoretical approach to all individual parts that make up the overall layout of the study. The 5 chapter is a detailed reference to the ATP-EMTP program which performed the simulation. The 6 chapter is the modeling of all elements of the layout and the incorporation into the ATP-EMTP. In chapter 7 we present the model of the insulator developed and in chapter 8 we present the simulation results and draw inferences about the layout.

Page generated in 0.0669 seconds