• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 236
  • 229
  • 26
  • 19
  • 18
  • 15
  • 14
  • 10
  • 8
  • 7
  • 6
  • 3
  • 2
  • 2
  • 2
  • Tagged with
  • 671
  • 199
  • 199
  • 82
  • 80
  • 79
  • 73
  • 71
  • 63
  • 61
  • 54
  • 43
  • 42
  • 39
  • 37
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
351

Využití ozónu v intenzivním chovu vybraných druhů ryb

VLČEK, Jakub January 2018 (has links)
Aim of this thesis was to use the ozonisation as a disinfection method for improving of water quality in the intensive fish farms using RAS (recirculating aquaculture system). The main assessed parameter was effect of ozone treatment on fish health and RAS functions and features. Two RAS were used in this study one with use of ozone treatment, one without ozone treatment (control system). There were cultured two different fish species in these two RAS - pikeperch (Sander lucioperca) and European catfish (Silurus glanis). The main reason for use of these two species is that they are perspective species for intensive aquaculture. In the RAS with ozone treatment, two different methods of ozone application were tested - periodical and continual application. The effect of ozone treatment on fish health and conditions was controlled regularly. Ozone treatment had positively affected the survival of both cultured species (pikeperch survival: with ozone = 77.0 % and without ozone = 67.2 %; European catfish: with ozone = 93.1 % and without ozone = 91.5 %). Ozone treatment also positively affected the water chemistry. The greatest difference was observed in CHSKMn: with ozone = 6.4?1.2 mg.l; without ozone = 10.7?1.6 mg.l. The same features were observed in suspended solids: with ozone = 4.3?2.8 mg.l-1; without ozone = 8.17?6.2 mg.l. Appearance of Ichthyophthirius multifiliis and bacterial infection were not affected by ozone treatment. The main result of this thesis and this design of experiment is that ozone treatment had a positive impact on water chemistry in observed RAS and it, however, didn't kill 100% of the fish pathogens.
352

Desinfecção de alginato

Meira, Daniela Martins January 2010 (has links)
A presente dissertação, composta de dois manuscritos, buscou preencher lacunas do conhecimento no que diz respeito à desinfecção de impressões de alginato. O primeiro trabalho foi realizado com o intuito de avaliar a eficácia antimicrobiana da solução de glutaraldeído 2% através do seu comportamento bactericida e bacteriostático quando utilizada para desinfecção de impressões de alginato dos pacientes de uma clínica de ensino odontológico de uma instituição federal, durante 28 dias. Logo após a ativação de 3L da solução desinfetante e sempre após a desinfecção de 10 impressões, foram coletadas amostras de 05 mL da solução para a análise microbiológica. No período avaliado, foram imersas 70 impressões de alginato na solução desinfetante. Nenhuma amostra apresentou bactérias viáveis, caracterizando o perfil bacteriostático da solução. Todas as amostras foram capazes de inibir o crescimento de Escherichia coli, Pseudomonas aeruginosa, e Staphylococcus aureus, confirmando o poder bactericida da solução, mostrando que um volume de 3L de glutaraldeído 2% é eficaz como desinfetante de até 70 impressões de alginato ao longo do período de 28 dias. O segundo estudo preocupou-se em avaliar a eficácia do glutaraldeído 2% e do ácido peracético 0,2% em eliminar o microrganismo Staphylococcus aureus, sabidamente presente nos corpos de prova de alginato. Os corpos de prova de alginato foram contaminados com caldo de cultura contendo S. aureus. Estes foram divididos em seis grupos: controle, lavado em água estéril, imersão em glutaraldeído 2% por 5 ou 10 min e imersão em em ácido peracético 0,2% por 5 ou 10 min. Após o tratamento, cada corpo de prova foi incubado em tubo de ensaio com 20 mL de caldo BHI estéril. Posteriormente, amostras do caldo de todos os grupos foram semeadas para determinar a presença de células viáveis. Os resultados mostraram que os grupos controle e o lavado em água estéril apresentaram crescimento bacteriano e que ambos desinfetantes foram eficazes em eliminar S. aureus do alginato tanto após 10 quanto 5 min, de imersão. Os achados desta dissertação permitem concluir que: 3L de solução de glutaraldeído são eficazes para desinfetar até 70 impressões de alginato e que o glutaraldeído 2% e o ácido peracético 0,2% são eficazes na desinfecção de alginato contaminado com S. aureus. / This research made an effort to amplify the knowledge about disinfection of alginate dental impression. The aim of the first study was to evaluate the efficacy of 2% glutaraldehyde solution after successive immersions of contaminated alginate impressions of dental patients from a Dental School by analyzing its bacteriostatic and bactericidal activity through 28 days. After the disinfection of every 10 alginate impressions a 10mL sample of the disinfectant solution (05mL) was collected to be microbiological analyzed. In this period, 70 alginate impressions were immersed in the solution. No viable bacterial grouth was observed at any of the microbiology analyses. All the samples tested were able to inhibit the bacterial growth of Escherichia coli, Pseudomonas aeruginosa and Staphylococcus aureus. The bacteriostatic and bactericidal activity of 2% glutaraldehyde solution was confirmed and 3L of the solution can be safetely used for the disinfection of at least 70 impression during 28 days. The aim of the second study was to evaluate the efficacy of 2% glutaraldehyde and 0.2% peracetic acid against Staphylococcus aureus. Alginate specimens were contaminated at S. aureus culture media. Specimens were divided into six groups: control, washed in sterile water, immersed in 2% glutaraldehyde for 5 or 10 minutes and immersed in 0,12% peracetic acid for 5 or 10 minutes. The results showed that control and sterile water showed bacterial growth and that both disinfectants (glutaraldehyde and peracetic acid) showed efficacy against S. aureus for both immersion period of time (5 and 10 minutes). The findings of these studies allowed the conclusion that 3L of glutaraldehyde solution showed efficacy to disinfect up to 70 alginate impressions and that, both 2% glutaraldehyde and 0.2% peracetic acid are efficient to disinfect S. aureus contamined alginate impressions.
353

Contaminação microbiológica e avaliação de métodos de higienização de panos de limpeza utilizados em serviços de alimentação / Microbial contamination and evaluation of two disinfection methods of cleaning cloths used in food services

Bartz, Sabrina January 2008 (has links)
Panos de limpeza têm sido considerados importantes fontes de contaminação cruzada, contudo seu uso continua muito freqüente em serviços de alimentação. O objetivo desse trabalho foi avaliar a contaminação e multiplicação microbiana, além de dois procedimentos de higienização de panos de limpeza. Em uma primeira etapa, 35 panos de limpeza foram coletados em serviços de alimentação da grande Porto Alegre, RS/Brasil e foram submetidos à quantificação de bactérias totais, coliformes e Staphylococcus coagulase positiva, aqui chamado de Staphylococcus aureus presuntivos. Os panos foram lavados manualmente e desinfetados por dois métodos, separadamente: a) fervura em água potável por 15 minutos e b) imersão em solução clorada a 200ppm, por 15 minutos, sendo enxaguados logo após. Os resultados demonstraram que a as contagens de bactérias totais variaram de 2,0 x 104 UFC/cm2 até 1,0 x 108 UFC/cm2, com média de 9,1 x 106 UFC/cm2. A contaminação por coliformes foi de 4,4 x 102 a 1,6 x 107 UFC/cm2, sendo que 40% das amostras apresentou contagens de aproximadamente 106 UFC/cm2. Quantidades de S. aureus presuntivos variaram de 1,0 x 104 UFC/cm2 a 2,8 x 106 UFC/cm2, com média de 4,6 x 105 UFC/cm2. De modo geral, panos desinfetados pelos dois métodos demonstraram reduções significativas (p < 0,05) do número de microrganismos, as quais foram de aproximadamente 5 ciclos logarítmicos. Em uma segunda etapa, panos contendo diferentes quantidades de matéria orgânica (0%, 1%, 5% e 10% de albumina bovina) foram contaminados com Salmonella Enteritidis 3091/05, Escherichia coli ATCC 25972, Staphylococcus aureus ATCC 25923 e Shigella sonnei CC07 e incubados por 1h, 2h, 3h e 4h, a 30 oC. A multiplicação foi avaliada por métodos microbiológicos e por bioluminescência gerada por ATP. Uma bactéria recombinante, ampicilina-resistente (HSα E. coli) foi utilizada para avaliar o potencial de dispersão de panos. Os resultados demonstraram que até duas horas de incubação não houve multiplicação expressiva de todos os microrganismos avaliados, no entanto, em três horas a maioria apresentou leve aumento da população. Uma exceção foi a S. Enteritidis que apresentou multiplicação significativamente maior (p < 0,05). Após quatro horas de incubação, todos os microrganismos apresentaram multiplicação significativa. A bioluminescência confirmou esses resultados e também demonstrou que diferentes quantidades de matéria orgânica não interferiram na multiplicação microbiana nas primeiras 3 a 4 horas. O experimento da dispersão bacteriana demonstrou que um pano contaminado com 104 UFC/cm2 foi capaz de transferir aproximadamente 102 UFC/cm2 de bactérias para uma superfície de aço inoxidável. Baseado nesses resultados, pode-se concluir que panos de limpeza utilizados em serviços de alimentação apresentavam nível elevado de contaminação, porém se adequadamente lavados e desinfetados, suas contagens podem ser significativamente reduzidas. Além disso, sugere-se que panos adequadamente desinfetados sejam utilizados por aproximadamente duas horas, não ultrapassando o período de três horas. / Cleaning cloths have been considered as important cause of cross-contamination, however its use remains frequent in food services. The objective of this study was to evaluate microbial contamination and multiplication, as well as two disinfection methods of cleaning cloths. In a first step of this work, samples (n=35) were collected in food services of Porto Alegre City, RS/Brazil and quantified for microbial contamination. Results indicated total aerobic counts varying from 2.0 x 104 cfu/cm2 up to 1.0 x 108 cfu/cm2, with mean numbers of 9.1 x 106 cfu/cm2. Coliform contamination varied from 4.4 x 102 up to 1.6 x 107 cfu/cm2 per cloth, and 40 % of the samples presented counts around 106 cfu/cm2, while presumptive S. aureus ranged from 1.0 x 104 cfu/cm2 up to 2.8 x 106 cfu/cm2, with mean numbers of 4.6 x 105 cfu/cm2. The cleaning cloths were disinfected in boiling water for 15 minutes and with 200 ppm sodium hypochlorite solution for 15 minutes, separately, demonstrating significant reductions (p < 0.05) of approximately 5 log. In a second step of this study, cloths containing 0 %, 1 %, 5%, and 10% of organic matter (bovine albumin) were contaminated with Salmonella Enteritidis 3091/05, Escherichia coli ATCC 25972, Staphylococcus aureus ATCC 25923 and Shigella sonnei CC07, and were incubated for 1 h, 2 h, 3 h, and 4 h, at 30 oC. Microbial multiplication was evaluated by bacterial counts and ATP bioluminescence, and an ampicilin-resistant recombinant HSα E. coli was used as a pathogen surrogate to investigate the potential of microbial cloth dispersion. The results demonstrate that until 2 hours of storage all strains did not present expressive growth. In 3 hours of storage the majority of the microorganisms showed slightly development, being that S. Enteritidis grown significantly better than other strains. In 4 hours of incubation all microorganisms demonstrate significant growth (p < 0.05). ATP bioluminescence confirmed the microbial count results and also demonstrates that different amounts of organic matter did not interfere with the bacterial multiplication at the first 3 to 4 hours of incubation. The dispersion experiment indicated that a cleaning cloth contaminated with 104 cfu/cm2 was able to spread approximately 102 cfu/cm2 recombinant E. coli onto a stainless steel surface. Based on these results it was possible to conclude that cleaning cloths used in food services were very contaminated, however adequate sanitation procedures could reduce significantly its microbial contamination. We suggested that an appropriate period of time to use disinfected cleaning cloths is around 2 hours, not exceeding 3 hours of usage.
354

Eficácia de desinfetantes frente bactérias sobreviventes a higienização de equipamentos de matadouro-frigorífico de bovinos

Molina, Paulo Duran dos Santos January 2009 (has links)
Na indústria da carne, a eficaz desinfecção das superfícies de contato com o alimento é uma importante barreira sanitária para evitar que os microrganismos deteriorantes e potencialmente patogênicos degradem o alimento ou ponham em risco a saúde dos consumidores. Com objetivo de monitorar a atividade antimicrobiana, pelo teste de suspensão, os desinfetantes quaternário de amônio, ácido peracético, clorhexidina, iodofor e hipoclorito de sódio foram confrontados com Escherichia coli, Staphylococcus aureus e dois pools de bactérias, todos organismos sobreviventes à higienização de um matadouro-frigorífico de bovinos com alta capacidade de abate. Os desinfetantes foram diluídos em graus geométricos com fator 0,5 formando cinco concentrações. Usaram-se os tempos de contato 5, 10, 15 e 20 minutos, e para simular deficiência de limpeza, à solução desinfetante foi adicionada 1% de matéria orgânica na forma de soro bovino estéril. Para análise estatística foi realizada a análise da variância com distribuição binomial para variável resposta. Com o delineamento da investigação e os organismos indicadores usados, as menores concentrações/tempo de contato para inativação de todas as bactérias foram: quaternário de amônio 25 ppm/20min. e 50 ppm/5min., ácido peracético 6,25 ppm/10min. e 25 ppm/5min., clorhexidina 200 ppm/5min. e 12,5 ppm/15min., iodofor 50 ppm/5min. e hipoclorito de sódio 200 ppm/5min. Todos os desinfetantes avaliados podem ser usados para inativar as bactérias sobreviventes no matadouro-frigorífico. Por outro lado, a simulação indica que a manipulação in loco dos fatores concentração, tempo de contato e matéria orgânica, entre outros, podem permitir a sobrevivência dos microrganismos no ambiente. / In the meat-processing industry, the efficient disinfection of meat contact surfaces is an important sanitary barrier to avoid deteriorating and potentially pathogenic microorganisms degrading the meat or pose a health hazard to consumers. Aiming to monitor antimicrobial activity through suspension test, the disinfectants ammonium quaternary, peracetic acid, chlorhexidine, iodophor and sodium hipochlorite were confronted with Escherichia coli, Staphylococcus aureus and two bacterial pools, all surviving organisms to hygienization in a bovine slaughterhouse with high slaughtering capability. The disinfectants were diluted in geometric degrees with factor 0,5, compounding five concentrations. Contact times were 5, 10, 15 and 20 minutes and, in order to simulate cleanliness deficiency to the disinfecting solution, 1% of organic matter in the form of sterile bovine serum was added. For statistical analysis, a variance analysis was effectuated with binomial distribution to variable response. Through this investigative line and the aforementioned indicator organisms, the lesser concentration per contact time to inactivate all bacterial culture were: ammonium quaternary 25 ppm/20min and 50 ppm/5min.; peracetic acid 6,25 ppm/10min and 25 ppm/5min.; chlorhexidine 200 ppm/5min and 12,5 ppm/15min.; iodophor 50 ppm/5 min and sodium hipochlorite 200 ppm/5 contact minutes. All evaluated disinfectants can be utilized to inactivate surviving bacterial cultures in the slaughterhouse. On the other hand, the simulation indicates that the in loco manipulation of factors concentration, contact time and organic matter, besides others, can allow the microorganisms survival in the medium.
355

Tratamento de água para consumo humano em comunidades rurais com utilização de moringa oleifera e desinfecção solar

Cangela, Geraldo Luís Charles de January 2014 (has links)
A utilização da Moringa oleifera (M.O) na clarificação de água seguida pela exposição solar como forma de desinfecção vem sendo usada em regiões desfavorecidas em infraestrutura e recursos financeiros. Essas tecnologias proporcionam as pessoas que habitam nessas regiões, água, de maneira fácil, autossustentável e a custo baixo. O objetivo do estudo foi de avaliar o uso conjunto da M.O na coagulação-floculação e do sistema solar na desinfeção da água para consumo humano. Os objetivos específicos da pesquisa foram: a) determinar a dose de M.O na remoção da turbidez e cor aparente da água bruta; b) determinar o tempo de exposição solar necessário para a remoção de E. coli e coliformes totais presentes na água clarificada com M.O; c) identificar com a técnica delineamento composto central rotacional (DCCR) quais variáveis independentes (pH, dosagem, tempo de mistura lenta e rápida) exerceram maior remoção da cor aparente e turbidez na água bruta. Na desinfeção solar foi considerado um tempo de exposição de 2, 4 e 6 horas, e para a determinação da dosagem e tempos ótimos foram realizados 28 ensaios em Jarteste. Os dados obtidos foram analisados através da Metodologia de Superfície de Resposta do DCCR do programa Statistic 8. As condições do ensaio que apresentou os melhores resultados foram: pH, 6,3; tempos de mistura rápida e lenta de 4 e 25 minutos, respectivamente; dosagem ótima de Moringa de 950 mg/L. Nestas condições, houve remoção de 80% da cor e 94% da turbidez. Adicionalmente, a clarificação com Moringa removeu 98,5 e 96,3% de coliformes totais e E. coli presentes na água bruta. A análise de variância mostrou que a dosagem ótima, os tempos de mistura rápida e lenta e a interação dos tempos de mistura lenta e rápida influenciaram na remoção da turbidez, enquanto a remoção de cor foi influenciada pela dosagem ótima e tempo de mistura lenta. As amostras com e sem filtração em filtro quantitativo de porosidade disforme (tecido de algodão de uso doméstico) foram expostas a desinfeção solar para a remoção de E. coli e coliformes totais. Houve eliminação de 64,8 e 59,7% em 2 horas; 100% e 99,7% em 4 horas e 100% em 6 horas para água não filtrada. Para água filtrada, as remoções foram de 70 e 19,2% (2 horas); 100 e 46% (4 horas) e 100% (6 horas). A desinfecção solar mostrou-se mais eficiente na exposição da água por 6 horas. Assim sendo, o uso conjunto da Moringa e da desinfeção solar em geral promoveram a clarificação e a desinfecção da água, reduzindo significativamente a turbidez e deixando-a livre de E. coli e coliformes totais. / The use of Moringa oleifera (M.O) in clarifying water followed by sunlight exposure as a means of disinfection has been used in disadvantaged areas with lack of infrastructure and financial resources. These technologies provide the people living in these regions, water in self-sustainable and cost-effective way. The objective of the study was to evaluate the combined use of M.O in coagulation-flocculation followed by solar disinfection to produce water suitable for human consumption. The specific objectives of the research were: a) to determine the optimal dose of M.O for removing turbidity and apparent color of the raw water; b) to determine the exposure time required for solar disinfection and removal from E. coli and total coliforms (TC) in the clarified water with M.O; c) to identify with the technical design central composite (CCRD) which independent variables (pH, dosage, slow and fast mixing time) had higher removal of apparent color and turbidity in the raw water. Exposure times tested in solar disinfection were 2, 4 and 6 hours. Twenty eight jartests were performed to determine the optimal dose, slow and fast mixing time and pH. Data were analyzed by CCRD Response Surface Methodology using the program Statistic 8. Test conditions that showed the best results were: pH, 6.3; fast and slow mixing times of 4 and 25 minutes, respectively; Moringa optimum dose of 950 mg/L. Under these optimal conditions, removals efficiencies for color and turbidity were, respectively, 80% of color and 94%. In additional, clarification with Moringa removed 98.5 and 96.3% of total coliforms and E. coli present in the raw water. Analysis of variance showed that the optimal dosage of the fast and slow mixing times, and the interaction of the fast and slow mixing times influenced the removal of turbidity, while the color removal was influenced by the optimum dosage and duration of slow mixing. The samples filtered in filter quantitative without unsightly porosity and were exposed to solar disinfection for removal of E. coli and total coliforms. There elimination 64.8 and 59.7% at 2 hours; 100% and 99.7% in 4 hours and 100% at 6 hours for unfiltered water. For filtered water removals were 70 and 19.2% (2 hours); 100 and 46% (4 hours) and 100% (6 h). Solar disinfection was more efficient in water exposure for 6 hours. It could be concluded that the joint use of the Moringa and solar disinfection generally promoted the clarification and disinfection of water, significantly reducing turbidity and leaving the water free of E. coli and total coliforms.
356

Influência da desinfecção de elastômeros com ácido paracético e água eletrolisada ácida / Influence of desinfection of elastomers with peracetic acid and acid electrolized water

Paulus, Marília January 2013 (has links)
O objetivo deste estudo foi avaliar a eficácia de duas soluções desinfetantes, ácido peracético e água eletrolisada ácida (AEA), na desinfecção de dois elastômeros, e a influência em suas propriedades de reprodução de detalhes e compatibilidade com o gesso. Um poliéter e uma silicona de adição foram manipulados, e a impressão de uma matriz apresentando três linhas (20, 50 e 75μm) de espessura e 25 mm de comprimento foi realizada. Após, os espécimes (n=3) foram imersos nas soluções de água destilada, glutaraldeído 2%, ácido peracético 0,2% e água eletrolisada ácida durante 10 minutos e, em seguida, o gesso tipo IV foi vazado sobre a impressão. Os materiais foram avaliados quanto à reprodução de detalhes e compatibilidade com o gesso. Posteriormente, biofilmes de Sthaphylococcus aureus foram cultivados sobre os espécimes durante 24 horas a 37°C. Após, os espécimes foram imersos durante 10 minutos nas soluções a seguir: solução salina estéril 0,89%, glutaraldeído 2%, ácido peracético 0,2% e água eletrolisada ácida. O biofilme presente em cada espécime foi coletado, diluído e alíquotas das diluições foram inoculadas em meio ágar sangue. Depois de 24 horas de incubação a 37°C, foi realizada a contagem do número de unidades formadoras de colônias bacterianas em cada um dos espécimes. Na reprodução de detalhes os resultados foram satisfatórios, pois a linha de 20 μm foi reproduzida em todos os espécimes. No teste de compatibilidade com o gesso, todos os grupos reproduziram a linha de 50 μm em todo o comprimento de 25 mm. Na análise antimicrobiana, os resultados mostraram que houve crescimento nos espécimes imersos em solução salina estéril (grupo controle negativo). Entretanto, não houve crescimento bacteriano nos espécimes imersos na solução de glutaraldeído 2%, ácido peracético 0,2% e AEA (p<0,001). Com base na metodologia realizada, concluiu-se que o ácido peracético e a água eletrolisada ácida não alteraram as propriedades dos elastômeros avaliados, e mostraram-se eficazes no processo de desinfecção destes materiais. / The aim of this study was to evaluate the efficacy of two disinfecting solutions (peracetic acid and acid electrolyzed water) in two elastomeric materials and the influence on its detail-reproduction properties and gypsum compatibility. Polyether and vinyl polysiloxane were handled, and impression of a metal mould with three lines (20, 50 and 75μm wide and 25mm long) was performed. After this, the impressions (n=3) were immersed in the following solutions, for 10 minutes: distilled water, glutaraldehyde 2%, peracetic acid 0,2% and acid electrolyzed water and then type IV gypsum was poured on the impression. The materials were evaluated as to detail reproduction the gypsum compatibility. Subsequently specimens were immersed for 10 minutes into the following solutions: 0.89% sterile saline solution, 2% glutaraldehide, 0.2% peracetic acid, and acid electrolyzed water. The biofilm in each sample was collected and diluted, and the aliquots of the dilution were inoculated in blood agar. After 24h incubation at 37°C, the colony forming units (CFU) were calculated. In the detail reproduction the results were satisfactory, as the 20 μm line was reproduced in all specimens. All specimens presented detail reproduction and gypsum compatibility after immersion. In the antimicrobial analysis, the results showed that the specimens immersed in sterile saline solution grew (negative control group). On the other hand, there was no bacterial growth in the specimens immersed in 2% glutaraldehyde, 0.2% paracetic acid, and acid electrolyzed water (p<0.001). Based on this study methodology, it is concluded that both peracetic acid and acid electrolyzed water did not influence the detail reproduction and gypsum compatibility were efficient in disinfecting the elastomeric materials.
357

Produção de água eletrolisada ácida para uso em odontologia

Campregher, Ulisses Bastos January 2011 (has links)
O objetivo desse trabalho foi desenvolver um aparelho experimental de baixo custo para produção de água eletrolisada ácida (AEA) e verificar sua eficácia na desinfecção de resina acrílica termo polimerizável (RA). Além disso, verificou-se a influência da AEA nas seguintes propriedades da RA. Sorção, Solubilidade, Resistência Flexural, Microdureza Knoop e Rugosidade Superficial. A AEA foi produzida através do processo de eletrólise de uma solução de NaCl a 5% numa célula eletrolítica de dois compartimentos separados por uma membrana semipermeável. Foram utilizados eletrodos de grafite e a diferença de potencial aplicada entre eles foi de 30 V, gerada por um alimentador com capacidade máxima de corrente de 2 A. Após 20 minutos de eletrólise a solução anódica (AEA) apresentou os seguintes parâmetros: pH 3,0 e potencial de óxi-redução de 1150 mV. O tempo de imersão na solução para o ensaios de desinfecção bem como os de propriedades características da RA foi de 10 minutos. A AEA foi eficaz na desinfecção da RA pois os corpos desinfectados não provocaram a turvação dos meios de cultura. A imersão em AEA aumentou estatisticamente (p<0,05) a sorção e a solubilidade da resina acrílica, porém os valores permaneceram dentro dos parâmetros estabelecidos pela ISO 1567. As demais propriedades da resina ficaram inalteradas (p>0,05). / The aim of this research was to develop a low cost experimental apparatus able to produce Electrolyzed Acidic Water (EAW) and verify its efficacy for disinfection of a denture base acrylic resin (AR). It was also verified the influence of EAW on the following properties of AR: Sorption, Solubility, Flexural Strength, Knoop Hardness and Superficial Rugosity. EAW was produced through an electrolysis process of an aqueous NaCl solution (5%) in an electrolytic two chambers cell with a separation membrane between the chambers. Graphite electrodes were used and the potential difference between them was 30 V, provided by a power supply with maximum amperage capacity of 2 A. 20 minutes after the begging of the electrolysis process the anodic solution (EAW) showed the following parameters: pH 3.0 and oxidation-reduction potential (ORP) of 1150 mV. The immersion time in the solution for the disinfection test and also for the evaluation of AR properties was 10 min. EAW was able to disinfect AR as the infected specimens did not cause turbidity of the culture medium. Immersion in EAW increased the sorption and decreased the solubility of the AR in a statistically significant way (p<0.05) but it was within the range required by ISO 1567. All the other AR properties suffered no changes (p<0.05)
358

Avaliação da contaminação microbiológica e de procedimentos de desinfecção de esponjas utilizadas em serviços de alimentação / Evaluation of microbiological contamination and disinfection procedures of sponges used in food services

Rossi, Eliandra Mirlei January 2010 (has links)
Esponjas de cozinha podem promover contaminação cruzada ao transferirem microrganismos de superfícies variadas para os alimentos. Os objetivos deste estudo foram avaliar a contaminação microbiológica e a eficácia de dois procedimentos de desinfecção de esponjas utilizadas em serviços de alimentação, bem como avaliar a transferência microbiana a partir de esponjas para o aço inoxidável e polietileno. Na primeira parte deste estudo, 80 esponjas naturalmente contaminadas foram coletadas em serviços de alimentação e então transferidas para o laboratório, onde foram divididas em três partes iguais. Uma das partes foi submetida à contagem de microrganismos heterotróficos (MH), coliformes a 45 oC (CF), Staphylococcus coagulase positiva (SA) e à pesquisa de Salmonella sp. (SAM). As outras duas partes foram submetidas, separadamente, à fervura em água durante cinco minutos e à desinfecção por hipoclorito de sódio 200ppm, por 10 minutos, adicionada de enxágue com água potável. Na segunda parte do estudo, 24 esponjas naturalmente contaminadas foram friccionadas sobre superfícies de aço inoxidável AISI 316 e polietileno, separadamente, a fim de investigar o número de microrganismos transferidos e sua sobrevivência. Os resultados demonstraram contaminações médias por MH de aproximadamente 9,1 LogUFC/esponja, e 76,25% delas apresentaram contagens médias de CF de aproximadamente 8,4 Log UFC/esponja. Apenas 2,5% das amostras apresentaram SA e SAM. Ambos os procedimentos de desinfecção foram capazes de reduzir significativamente as contagens bacterianas, porém a fervura demonstrou reduções maiores (6,7 Log UFC/esponja) que a desinfecção por hipoclorito de sódio a 200ppm (2,7 Log UFC/esponja ). A média de transferência de microrganismos variou entre 3,3 e 5,5 LogUFC/cm2, para aço inoxidável, entre 3,5 e 5,6 LogUFC/cm2, para o polietileno, sendo que os microrganismos transferidos foram perdendo sua viabilidade sobre ambos materiais. Nas primeiras quatro horas de exposição em temperatura ambiente a redução do número de microrganismos foi mais acentuada, e em 24 horas restaram cerca de 1 a 2 logUFC/cm2 de microrganismos viáveis. / Kitchen sponges can promote cross-contamination by transferring microorganisms from various surfaces to food. The objectives of this study were to evaluate the microbiological contamination and effectiveness of two procedures for disinfection of sponges used in food services, and to assess the microbial transfer from sponges to stainless steel and polyethylene. In the first part of this study, 80 sponges were collected in food services and then transferred to the laboratory where they were divided into three equal parts. One part was subjected to quantification of heterotrophic microorganisms (HM), fecal coliforms (CF), Staphylococcus coagulase-positive (SA) and Salmonella sp. (SAM). The other two parts were separately subjected to boilling in water for five minutes, and disinfection by sodium hypochlorite 200ppm for 10 minutes, added by rinse with water. In the second part of the study, 24 naturally contaminated sponges were rubbed on surfaces of AISI 316 stainless steel and polyethylene, separately, to investigate the number of transferred microorganisms and their survival. The results showed contamination averages by HM of approximately 9.1 log CFU/sponge, and 76.25% had average scores of CF of about 8.4 log CFU/sponge. Both disinfection procedures were able to significantly reduce bacterial counts, but the boiling showed greater reductions (6.7 log CFU/sponge) than the disinfection by sodium hypochlorite at 200ppm (2.7 log CFU/sponge) The average transfer of microorganisms varied between 3.3 and 5.5 log CFU/cm2 for stainless steel, and 3.5 to 5.6 log CFU/cm2, for polyethylene, and the transferred microorganisms were losing their viability on both materials. In the first four hours of exposure at room temperature the reduction of the number of microorganisms was more pronounced, and in 24 hours there were about 1 to 2 log CFU/cm2 remaining viable microorganisms.
359

Avaliação da influência da incorporação de substâncias desinfetantes na resistência à compressão e à tração diametral de dois gessos tipo IV

Batista, André Ulisses Dantas [UNESP] 21 February 2005 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:01Z (GMT). No. of bitstreams: 0 Previous issue date: 2005-02-21Bitstream added on 2014-06-13T19:05:06Z : No. of bitstreams: 1 batista_aud_dr_arafo.pdf: 615250 bytes, checksum: 0ecd726c988be8090372e448348080fd (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo deste estudo foi analisar a influência da incorporação de três desinfetantes (hipoclorito de sódio a 1%, glutaraldeído alcalino a 2% e digluconato de clorexidina a 2%) em duas diferentes porcentagens de substituição da água da espatulação (50 e 100%) de dois gessos tipo IV, FujiRock EP (M1) e Rock Plus (M2), avaliando-se a resistência à compressão e à tração diametral. Os corpos-de-prova foram obtidos a partir de matrizes metálicas bipartidas com 20 mm de diâmetro e 40 mm de altura (resistência à compressão) e 20 mm de diâmetro e 10 mm de altura (resistência à tração diametral). As matrizes foram fixadas sobre uma placa de vidro, o gesso foi manipulado na proporção água/pó recomendada pelos fabricantes (M1:20ml/100g e M2:19 ml/100g), em um espatulador mecânico por 30 segundos, e vazado sob vibração. Para cada ensaio foram confeccionados sete grupos para cada gesso (n=10). Os grupos foram: CONTROLE (Água destilada), G50 (substituição de 50% da água de espatulação por glutaraldeído), G100 (100% de glutaraldeído), C50 (substituição de 50% da água por clorexidina), C100 (100% de clorexidina), H50 (substituição de 50% da água por hipoclorito) e H100 (100% de hipoclorito). Após a presa os corpos-de-prova foram removidos das matrizes e armazenados à temperatura ambiente. Os ensaio de compressão e tração diametral foram realizados 24 horas após o vazamento, em uma máquina de ensaios MTS-810, com célula de carga de 100 KN à velocidade de 0,5mm/min. Os valores médios de resistência à compressão e à tração diametral (MPa) foram submetidos à análise de variância e teste de Tukey, com nível de significância de 95%, permitindo concluir que: (a) a incorporação das substâncias desinfetantes estudadas afetou a resistência à compressão de ambos os gessos analisados; (b) as diferentes proporções de incorporação das substâncias... / The purpose of this study was to evaluate the compressive and diametral tensile strength of two Type IV dental stones, FujiRock EP (M1) e Rock Plus (M2), mixed with three disinfectant solutions (sodium hypochlorite 1%, chlorhexidine digluconate 2% and glutaraldehyde 2%) in two different proportions of gauging water (50% and 100%). Compressive samples consisted of cylindrical specimens, each having a diameter of 20 mm and length of 40 mm, and diametral tensile specimens consisted of discshaped specimens, having a diameter of 20 mm and length of 10 mm, obtained from split metal molds. The stone was mixed with the solutions previously outlined at the water-powder ratio recommended by the manufacturers (M1:20ml/100g e M2:19 ml/100g), mechanically spatulated under vacuum (Turbomix) for 30 seconds, and gently vibrated in the molds. Seven groups were prepared for each test, with 10 samples each, as follows: CONTROL (distilled water), G50 (substitution of 50% of gauging water by glutaraldehyde), G100 (only glutaraldehyde), C50 (substitution of 50% of gauging water by chlorhexidine digluconate), C100 (only chlorhexidine digluconate), H50 (substitution of 50% of gauging water by sodium hypochlorite) and H100 (only sodium hypochlorite). Specimens were removed from the molds after they set. Compressive strength and diametral tensile strength was determined 24 hours the specimens were cast, in an MTS-810 testing machine, with a cross-head speed of 0,5mm/min. Mean compressive and diametral tensile strength was calculated and expressed in megapascals (MPa). Data from both tests were analyzed by ANOVA and Tukey test, showing that: (a) chemical disinfectants incorporation reduced the compressive strength of type IV dental stones evaluated; (b) the use of two different proportions of gauging water substitution by disinfectants (50% and 100%) has affected the compressive strength of only one die stone (M1); (c) chemical disinfectants incorporation did not reduced.
360

Desinfecção de próteses totais por micro-ondas: efeito da frequência de irradiação no tratamento da estomatite protética

Silva, Mariana Montenegro [UNESP] 02 July 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:02Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-07-02Bitstream added on 2014-06-13T20:25:46Z : No. of bitstreams: 1 silva_mm_dr_arafo.pdf: 1652130 bytes, checksum: eaecac9589dd6ffc2956dbdbed520b60 (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / A estomatite protética é uma infecção fúngica que acomete entre 60% e 72% dos indivíduos portadores de próteses removíveis, sobretudo idosos do gênero feminino. Atualmente, a desinfecção de próteses totais por meio da irradiação por micro-ondas tem sido recomendada para tratamento e prevenção da estomatite protética. Considerando esses aspectos, esse estudo in vivo avaliou a efetividade da frequência da desinfecção de próteses totais por micro-ondas (3 min/650 W) em relação à terapia antifúngica tópica para o tratamento da estomatite protética, além de verificar a prevalência de Candida nos pacientes avaliados. Para isso, foram selecionados 60 indivíduos, portadores de próteses totais superiores e com diagnóstico clínico de estomatite protética. Esses pacientes foram aleatoriamente distribuídos em 3 grupos (n=20), de acordo com o tratamento instituído: Terapia Antifúngica Tópica (Grupo I) - utilização de nistatina (suspensão oral, 100.000 UI/mL), 4 vezes ao dia durante 15 dias; Irradiação por Micro-ondas – imersão das próteses totais em água e irradiação das próteses por micro-ondas durante 3 minutos a 650 W, 1 ou 3 vezes por semana (Grupos II e III, respectivamente) por um período de 15 dias. Para avaliação da efetividade dos tratamentos instituídos, foram realizadas culturas micológicas quantitativas e identificação das espécies de Candida, utilizando-se o meio CHROMagar Candida, análise de microcultivo, teste de triagem em caldo hipertônico e o sistema bioquímico de identificação ID 32C. Coletas de biofilme das superfícies internas das próteses totais superiores e das mucosas palatinas de todos os pacientes, foram realizadas previamente ao tratamento (dia 0) e após 15 dias do seu início. Com o objetivo de avaliar a efetividade dos tratamentos em longo prazo, a quantificação de colônias viáveis de Candiada spp... / Denture stomatitis is a fungal infection that affects 60% to 72% of individuals who use removable dentures, primarily elderly women. Currently, the disinfection of complete dentures using microwave irradiation has been recommended to treat and prevent denture stomatitis. Considering these aspects, this in vivo study evaluated the effectiveness of the frequency of complete denture disinfection using microwaves (3 min/650 W) compared to antifungal therapy for the treatment of denture stomatitis. It also verified the prevalence of Candida spp. in the evaluated patients. This study used a sample of 60 healthy individuals who use complete upper dentures and have received a clinical diagnosis of denture stomatitis. Patients were randomly distributed into three groups (n=20), based on the treatment used: Topical Antifungal Therapy (Group I) – use of nystatin (oral suspension, 100.000 UI/mL), four times a day for 15 days; Irradiation with Microwaves – irradiation of the dentures by microwaves for three minutes at 650 W, one time or three times per week (Groups II and III, respectively) for a period of 15 days. In order to evaluate the effectiveness of the treatments used, quantitative mycological cultures were collected and the Candida species were identified using the CHROMagar Candida method, microculture analysis, screening test in hypertonic broth and the ID 32C biochemical identification system. Biofilm samples were collected from the inner surfaces of the complete upper dentures and from the palatal mucosa of all patients before (day 0) and after 15 days of treatment. In order to evaluate the effectiveness of the treatments over the long term, the quantification of the viable Candiada spp. colonies was repeated 30, 60 and 90 days after starting the treatment. For each consultation (days 0, 15, 30, 60 and 90), a clinical evaluation was also performed through intra-oral photography... (Complete abstract click electronic access below)

Page generated in 0.0894 seconds