• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 236
  • 229
  • 26
  • 19
  • 18
  • 15
  • 14
  • 10
  • 8
  • 7
  • 6
  • 3
  • 2
  • 2
  • 2
  • Tagged with
  • 673
  • 199
  • 199
  • 83
  • 81
  • 79
  • 73
  • 71
  • 63
  • 61
  • 54
  • 43
  • 42
  • 39
  • 37
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
381

Avaliação da desinfecção do canal radicular frente ao preparo químico-cirúrgico por meio rotatório associado ou não a tratamento químico complementar / Assessment of the disinfection of root canals using a rotatory system associated or not to a complementary chemical treatment

Soraia Veloso Silva Santana 09 April 2008 (has links)
A desinfecção dos canais radiculares figura como constante preocupação clínica. Esta pesquisa teve a proposta de verificar o nível de desinfecção alcançado pela instrumentação mecanizada utilizando o sistema K3 em relação ao uso desse mesmo sistema associado a um tratamento químico dentinário complementar. Foram utilizados 16 caninos inferiores unirradiculares, que foram aleatoriamente divididos em dois grupos. Foram realizados 2 ensaios em dias diferentes, cada ensaio formado por 8 dentes em cada grupo. As coroas dos dentes foram cortadas e o tamanho das raízes padronizado em 15 mm. Os canais foram esvaziados com auxilio de limas tipo K de números 10 ou 15 com hipoclorito de sódio a 1% seguido de 20 mL de tiosulfato de sódio a 5%. Seguiu-se então a odontometria. Os dentes foram impermeabilizados externamente por duas camadas de cianoacrilato de etila e montados em tubos Eppendorf a expensas de adesivo epóxico. Os conjuntos (raiz + Eppendorf) foram esterilizados em autoclave por 20 min a 134 °C. Os espécimes foram inoculados com uma da suspensão correspondente à concentração bacteriana 0,5 da escala de Mc Farland (1,5 x 108 UFC). A primeira coleta microbiológica foi realizada imediatamente após o tempo de incubação para estabelecer o número de unidades formadoras de colônias. O preparo químicocirúrgico dos canais radiculares do grupo 1 foi realizado apenas por meio do sistema rotatório K3. Cones de papel absorvente esterilizados foram inseridos no canal radicular para nova coleta. Os dentes do Grupo 2 também tiveram os canais radiculares preparados com sistema rotatório K3 até a fase de irrigação-aspiração final com hipoclorito de sódio a 0,5% e EDTA-T a 17%. Após essa etapa foi realizado o tratamento químico da dentina que correspondeu à inserção de solução de hipoclorito de sódio a 1% no interior da cavidade pulpar e com uma lima tipo K de número 25 a solução foi agitada durante um minuto. Esse procedimento foi repetido 5 vezes num total de 10 mL dessa substância e somando um tempo de 10 minutos. A irrigação final foi efetuada com 10 mL de solução de hipoclorito de sódio a 0,5% seguidas de 20 mL de solução de EDTA- T a 17% (pH 7,0). Nova coleta para exame microbiológico foi realizada. Essas suspensões sofreram diluições seriadas de 10-1 a 10-7 em água peptonada antes do preparo químico-cirúrgico e de10-1 a 10-5 após o mesmo As diluições foram então semeadas em triplicata em placas contendo TSA. Após o período de 24 h de incubação as placas que apresentaram crescimento bacteriano tiveram o número de unidades formadoras de colônias (UFCs) determinado. Embora houvesse redução da população bacteriana em ambos os grupos no que se refere ao pré e pós-operatório, os resultados demonstraram que não houve diferença estatística significante entre os grupos de estudo (p>0,05). / The effective disinfection of root canals represents a constant clinical concern. This research aimed at verifying the level of disinfection achieved by mechanical instrumentation using the K3 system when compared to the associated use of the same system and a complementary chemical dentinal treatment. Sixteen singlerooted lower canines were randomly divided into two groups. Two experiments, each using 8 teeth per group, were conducted on different days. The dental crowns were sectioned and the root length was standardized to 15 mm. The canals were instrumented using #10 or 15 K-files with 1% sodium hypochlorite, followed by 5% sodium thiosulfate. The root canals were measured. The teeth were made externally impermeable by two layers of ethyl cyanoacrylate and placed in Eppendorf tubes using epoxy resin. The compounds (root + Eppendorf) were sterilized in an autoclave for 20 min at 134oC. A suspension that corresponds to the bacterial concentration of 0.5 on the McFarland scale (1.5 x 108 CFU) was inoculated onto the specimens. The first microbiological sample collection was done immediately after incubation in order to determine the number of colony-forming units. Chemical preparation of the root canals of group 1 was done using the K3 rotatory system exclusively. Sterile paper cones were inserted into the canal for a new collection. Teeth from group 2 also had their root canals prepared using the K3 rotatory system up to the phase of final irrigation with 0.5% sodium hypochlorite and 17% EDTA-T. Next, chemical dentinal treatment was done by inserting a 1% sodium hypochlorite solution into the pulp cavity and agitating for one minute with the aid of a #25 K-file. This step was repeated 5 times using a total of 10 ml of the solution for a total duration of 10 minutes. Final irrigation was done using 10 ml of 0.5% sodium hypochlorite solution followed by 20 ml of 17% EDTA-T (pH 7.0). A new collection for microbiological examination was done. These suspensions underwent serial dilutions from 10-1 to 10- 7 using peptone water before preparation and from 10-1 to 10-5 afterwards. The dilutions were then inoculated thrice onto TSA plates. After an incubation period of 24h, the number of colony-forming units (CFU) was determined for the plates which presented with bacterial growth. Although there was a reduction of the bacterial population in both experimental groups when pre and post-operative counts were compared, results demonstrated that there was no statistically significant difference between the two study groups (p>0.05).
382

Estudo crítico dos métodos moleculares utilizando iniciadores universais na identificação da microbiota endodôntica e da desinfecção do sistema de canais radiculares / Critical study of the molecular methods using universal primers for the identification of endodontic microbiota and disinfection the root canal system

Regina Célia Furukava Shin 11 September 2012 (has links)
No sentido de colaborar com o estudo da redução de microrganismos em Endodontia, foi realizada uma análise crítica dos modelos metodológicos in vivo sobre as técnicas moleculares utilizadas na avaliação da microbiota endodôntica e na capacidade de medir a antissepsia que o tratamento endodôntico proporciona. Desta maneira, os trabalhos foram agrupados de acordo com a proposta do presente estudo. Na análise critica e comparativa, pode-se observar uma grande variedade de métodos moleculares aplicados nos estudos, sendo que o mais utilizado nos ensaios para avaliação da microbiota foi o PCR. Havia estudos que utilizavam uma combinação de vários métodos onde foi possível identificar microrganismos ainda não conhecidos. Nos ensaios que utilizam iniciadores universais e que se valem da identificação de microrganismos através do DNA, foram listados de maneira a poder observar que o iniciador universal formado pela seguinte cadeia de oligonucleotídeos: F: 5- AGA GTT TGA TCC TGG CTC AG-3/R: 5-ACG GCT ACC TTG TTA CGA CTT-3 foi o mais descrito pela literatura. / In order to collaborate with the study of disinfection in Endodontics, was performed a study of critical methodological models in vivo on the molecular techniques used in the evaluation of endodontic microbiota and the ability to measure the disinfection capacity of endodontic treatment. Thus, the studies were grouped according to the purpose of this study. Under in critical and comparative analysis its can be seen a wide variety of molecular techniques used in the studies, and as used in the tests was to evaluate the microbial PCR studies using a combination of various methods which could be identified microorganisms has not known. In assays using universal primers which rely on the identification of microorganisms using the DNA, were listed as to be able to observe that the universal primer chain formed by the following primers: F: 5\'-AGA GTT TGA TCC TGG CTC AG-3 \'/ R: 5\'-ACG GCT ACC TTG TTA CGA CTT-3\' was as described in the literature.
383

Investigação da toxicidade, tratabilidade e formação de subprodutos tóxicos em efluentes clorados de lagoas de estabilização com e sem pós-tratamento. / Investigation of toxicity, treatability and toxic disinfection by-products formation in chlorinated stabilization ponds effluents with and without post-treatment.

Luís Fernando Rossi Léo 16 April 2008 (has links)
Entre as principais dificuldades que os sistemas de tratamento de esgotos domésticos compostos por lagoas de estabilização enfrentam para atender as exigências impostas pela Resolução CONAMA 357/2005 podem se destacar as concentrações elevadas de nitrogênio amoniacal, fósforo e coliformes fecais e totais. Estes últimos, quando os sistemas utilizam corpos receptores classe 2 ou 3 geram a necessidade de desinfecção. Dentre as diversas tecnologias disponíveis para a desinfecção dos esgotos, a cloração é bastante atrativa pelo custo reduzido, em relação às outras tecnologias, bem como pela elevada experiência que as companhias e municipalidades possuem neste tipo de sistema, advinda dos sistemas de tratamento de água. Dentre os sistemas de cloração, o uso de hipoclorito de sódio torna-se interessante pela segurança, simplicidade das instalações e de operação. A desvantagem do uso deste tipo de sistema se dá na possibilidade da formação de subprodutos tóxicos, dentro os quais pode-se destacar os trihalometanos (THMs) e os ácidos haloacéticos (AHAs), porém esta formação pode ser teoricamente reduzida pela presença de elevadas concentrações de nitrogênio amoniacal nos efluentes destes sistemas, por sua reação preferencial com o cloro, na formação de cloraminas. Outras possibilidades de redução na formação é reduzir a concentração de precursores, reduzir a dosagem de cloro e utilizar método de descloração dos efluentes após a desinfecção. Este trabalho, ambientado no desenvolvimento das pesquisas do Edital 4 do PROSAB/FINEP (Programa Nacional de Pesquisa em Saneamento Básico), desenvolveu testes de desinfecção em efluentes de lagoas anaeróbias e facultativas utilizando como desinfetante hipoclorito de sódio, em dosagens de 8,0 mgCl/L e 12,0 mgCl/L. Desenvolveu também testes de desinfecção com efluentes anaeróbios e facultativos pós-tratados por meio de coagulação/floculação/sedimentação e coagulação/floculação/flotação com ar dissolvido, com dosagens de 2,0 mgCl/L e 4,0 mgCl/L. Para todos os testes de desinfecção foram realizados também testes de descloração das amostras. Desta forma foi possível estudar, dentro de uma faixa limitada, as possibilidades de reduzir a formação de subprodutos tóxicos na desinfecção de efluentes de lagoas de estabilização com hipoclorito de sódio. Nas amostras foram determinados por meio de cromatografia gasosa as concentrações dos THMs e AHAs. Por meio das metodologias do Standard Methods 20th Edition foram realizadas as análises físico-químicas dos parâmetros pH, temperatura, DQO, DBO, Ntotal, N-NH3, NTK, cloro livre, cloraminas, coliformes e outros microrganismos indicadores. A formação de THMs se mostrou bastante pequena, em média abaixo dos 20,0 µg/L em todos os testes, aparentemente devido às elevadas concentrações de N-NH3, da ordem de 30,0 mg/L. O mesmo não ocorreu com os AHAs. Em muitos testes a concentração encontrada de AHAs totais superou o padrão de 80,0 µg/L preconizados pela USEPA para água potável, e aqui adotado como padrão comparativo. A descloração reduziu em média 52% a concentração de AHAs nos testes, colocando quase todas as amostras dentro do padrão de 80,0 µg/L. Os bioensaios mostraram que a presença de cloro livre nas amostras eleva a toxicidade aguda em Daphnia similis provocada pelos efluentes e que a cloração seguida de descloração produz efluentes com toxicidade inferior à toxicidade dos efluentes apenas clorados e toxicidade também inferior àquela dos efluentes sem cloração. / The main difficulties that the stabilization ponds for sewage treatment systems face to meet the requirements imposed by CONAMA Resolution 357/2005 can highlight the high concentrations of ammonia nitrogen, phosphorus and fecal and total coliform. When the systems use receivers water bodies Class 2 or 3 generate the need for disinfection. Among the different technologies available for the disinfection of sewage, the chlorination is very attractive at reduced cost compared to other technologies, as well as the high experience that companies and municipalities have in this type of system, because the water treatment systems. About the chlorination technologies, the use of sodium hypochlorite becomes interesting for security, simplicity of installation and operation. The disadvantage of using this type of system is given the possibility of formation of toxic by-products, within which you can highlight the trihalomethanes (THMs) and haloacetic acids (AHAs), but this formation can theoretically be reduced by the presence of high concentrations of ammoniacal nitrogen in effluents of these systems, for its preferential reaction with the chlorine in the formation of cloraminas. Other possibilities for reducing the training is to reduce the concentration of precursors (organic matter), reduce the dosage of chlorine and use dechlorination method after disinfection. This work, developed in PROSAB / FINEP (National Program for Research on Sanitation) research announcement number 4, developed tests for disinfection of anaerobic and facultative ponds effluents using sodium hypochlorite as a disinfectant, in concentrations of 8.0 mgCl/L and 12.0 mgCl/L. Were also developed tests for disinfection with anaerobic and facultative ponds effluents post-treated by coagulation / flocculation / sedimentation and coagulation / flocculation / flotation with dissolved air, with concentrations of 2.0 mgCl/L and 4.0 mgCl/L. For all of disinfection tests were also conducted dechlorination tests. This made it possible to study the possibilities of reducing the formation of toxic byproducts of the stabilization ponds effluents disinfection with sodium hypochlorite. The THMs and AHAS concentrations were determined by gas chromatography. Through the methods of Standard Methods 20th Edition analyses were carried out physical-chemical parameters of pH, temperature, COD, BOD, total nitrogen, ammoniacal nitrogen, total Kjeldhal nitrogen, free chlorine, chloramines, coliforms and other indicator microorganisms. The formation of THMs was very low, on average below the 20.0 µg/L in all tests, apparently due to high concentrations of NH3-N, the order of 30.0 mg/L. The same did not occur with AHAs. In many tests found concentrations of AHAs exceeded the standard of 80.0 µg/L recommended by the USEPA for drinking water. Dechlorination reduced 52% of AHAs concentrations, in average. Bioassays showed that the presence of free chlorine in the samples increase the acute toxicity in Daphnia similes. Chlorination followed by dechlorination produces effluents with less toxicity than the toxicity of chlorinated and effluent without chlorination.
384

Desinfecção de alginato

Meira, Daniela Martins January 2010 (has links)
A presente dissertação, composta de dois manuscritos, buscou preencher lacunas do conhecimento no que diz respeito à desinfecção de impressões de alginato. O primeiro trabalho foi realizado com o intuito de avaliar a eficácia antimicrobiana da solução de glutaraldeído 2% através do seu comportamento bactericida e bacteriostático quando utilizada para desinfecção de impressões de alginato dos pacientes de uma clínica de ensino odontológico de uma instituição federal, durante 28 dias. Logo após a ativação de 3L da solução desinfetante e sempre após a desinfecção de 10 impressões, foram coletadas amostras de 05 mL da solução para a análise microbiológica. No período avaliado, foram imersas 70 impressões de alginato na solução desinfetante. Nenhuma amostra apresentou bactérias viáveis, caracterizando o perfil bacteriostático da solução. Todas as amostras foram capazes de inibir o crescimento de Escherichia coli, Pseudomonas aeruginosa, e Staphylococcus aureus, confirmando o poder bactericida da solução, mostrando que um volume de 3L de glutaraldeído 2% é eficaz como desinfetante de até 70 impressões de alginato ao longo do período de 28 dias. O segundo estudo preocupou-se em avaliar a eficácia do glutaraldeído 2% e do ácido peracético 0,2% em eliminar o microrganismo Staphylococcus aureus, sabidamente presente nos corpos de prova de alginato. Os corpos de prova de alginato foram contaminados com caldo de cultura contendo S. aureus. Estes foram divididos em seis grupos: controle, lavado em água estéril, imersão em glutaraldeído 2% por 5 ou 10 min e imersão em em ácido peracético 0,2% por 5 ou 10 min. Após o tratamento, cada corpo de prova foi incubado em tubo de ensaio com 20 mL de caldo BHI estéril. Posteriormente, amostras do caldo de todos os grupos foram semeadas para determinar a presença de células viáveis. Os resultados mostraram que os grupos controle e o lavado em água estéril apresentaram crescimento bacteriano e que ambos desinfetantes foram eficazes em eliminar S. aureus do alginato tanto após 10 quanto 5 min, de imersão. Os achados desta dissertação permitem concluir que: 3L de solução de glutaraldeído são eficazes para desinfetar até 70 impressões de alginato e que o glutaraldeído 2% e o ácido peracético 0,2% são eficazes na desinfecção de alginato contaminado com S. aureus. / This research made an effort to amplify the knowledge about disinfection of alginate dental impression. The aim of the first study was to evaluate the efficacy of 2% glutaraldehyde solution after successive immersions of contaminated alginate impressions of dental patients from a Dental School by analyzing its bacteriostatic and bactericidal activity through 28 days. After the disinfection of every 10 alginate impressions a 10mL sample of the disinfectant solution (05mL) was collected to be microbiological analyzed. In this period, 70 alginate impressions were immersed in the solution. No viable bacterial grouth was observed at any of the microbiology analyses. All the samples tested were able to inhibit the bacterial growth of Escherichia coli, Pseudomonas aeruginosa and Staphylococcus aureus. The bacteriostatic and bactericidal activity of 2% glutaraldehyde solution was confirmed and 3L of the solution can be safetely used for the disinfection of at least 70 impression during 28 days. The aim of the second study was to evaluate the efficacy of 2% glutaraldehyde and 0.2% peracetic acid against Staphylococcus aureus. Alginate specimens were contaminated at S. aureus culture media. Specimens were divided into six groups: control, washed in sterile water, immersed in 2% glutaraldehyde for 5 or 10 minutes and immersed in 0,12% peracetic acid for 5 or 10 minutes. The results showed that control and sterile water showed bacterial growth and that both disinfectants (glutaraldehyde and peracetic acid) showed efficacy against S. aureus for both immersion period of time (5 and 10 minutes). The findings of these studies allowed the conclusion that 3L of glutaraldehyde solution showed efficacy to disinfect up to 70 alginate impressions and that, both 2% glutaraldehyde and 0.2% peracetic acid are efficient to disinfect S. aureus contamined alginate impressions.
385

Tratamento de água para consumo humano em comunidades rurais com utilização de moringa oleifera e desinfecção solar

Cangela, Geraldo Luís Charles de January 2014 (has links)
A utilização da Moringa oleifera (M.O) na clarificação de água seguida pela exposição solar como forma de desinfecção vem sendo usada em regiões desfavorecidas em infraestrutura e recursos financeiros. Essas tecnologias proporcionam as pessoas que habitam nessas regiões, água, de maneira fácil, autossustentável e a custo baixo. O objetivo do estudo foi de avaliar o uso conjunto da M.O na coagulação-floculação e do sistema solar na desinfeção da água para consumo humano. Os objetivos específicos da pesquisa foram: a) determinar a dose de M.O na remoção da turbidez e cor aparente da água bruta; b) determinar o tempo de exposição solar necessário para a remoção de E. coli e coliformes totais presentes na água clarificada com M.O; c) identificar com a técnica delineamento composto central rotacional (DCCR) quais variáveis independentes (pH, dosagem, tempo de mistura lenta e rápida) exerceram maior remoção da cor aparente e turbidez na água bruta. Na desinfeção solar foi considerado um tempo de exposição de 2, 4 e 6 horas, e para a determinação da dosagem e tempos ótimos foram realizados 28 ensaios em Jarteste. Os dados obtidos foram analisados através da Metodologia de Superfície de Resposta do DCCR do programa Statistic 8. As condições do ensaio que apresentou os melhores resultados foram: pH, 6,3; tempos de mistura rápida e lenta de 4 e 25 minutos, respectivamente; dosagem ótima de Moringa de 950 mg/L. Nestas condições, houve remoção de 80% da cor e 94% da turbidez. Adicionalmente, a clarificação com Moringa removeu 98,5 e 96,3% de coliformes totais e E. coli presentes na água bruta. A análise de variância mostrou que a dosagem ótima, os tempos de mistura rápida e lenta e a interação dos tempos de mistura lenta e rápida influenciaram na remoção da turbidez, enquanto a remoção de cor foi influenciada pela dosagem ótima e tempo de mistura lenta. As amostras com e sem filtração em filtro quantitativo de porosidade disforme (tecido de algodão de uso doméstico) foram expostas a desinfeção solar para a remoção de E. coli e coliformes totais. Houve eliminação de 64,8 e 59,7% em 2 horas; 100% e 99,7% em 4 horas e 100% em 6 horas para água não filtrada. Para água filtrada, as remoções foram de 70 e 19,2% (2 horas); 100 e 46% (4 horas) e 100% (6 horas). A desinfecção solar mostrou-se mais eficiente na exposição da água por 6 horas. Assim sendo, o uso conjunto da Moringa e da desinfeção solar em geral promoveram a clarificação e a desinfecção da água, reduzindo significativamente a turbidez e deixando-a livre de E. coli e coliformes totais. / The use of Moringa oleifera (M.O) in clarifying water followed by sunlight exposure as a means of disinfection has been used in disadvantaged areas with lack of infrastructure and financial resources. These technologies provide the people living in these regions, water in self-sustainable and cost-effective way. The objective of the study was to evaluate the combined use of M.O in coagulation-flocculation followed by solar disinfection to produce water suitable for human consumption. The specific objectives of the research were: a) to determine the optimal dose of M.O for removing turbidity and apparent color of the raw water; b) to determine the exposure time required for solar disinfection and removal from E. coli and total coliforms (TC) in the clarified water with M.O; c) to identify with the technical design central composite (CCRD) which independent variables (pH, dosage, slow and fast mixing time) had higher removal of apparent color and turbidity in the raw water. Exposure times tested in solar disinfection were 2, 4 and 6 hours. Twenty eight jartests were performed to determine the optimal dose, slow and fast mixing time and pH. Data were analyzed by CCRD Response Surface Methodology using the program Statistic 8. Test conditions that showed the best results were: pH, 6.3; fast and slow mixing times of 4 and 25 minutes, respectively; Moringa optimum dose of 950 mg/L. Under these optimal conditions, removals efficiencies for color and turbidity were, respectively, 80% of color and 94%. In additional, clarification with Moringa removed 98.5 and 96.3% of total coliforms and E. coli present in the raw water. Analysis of variance showed that the optimal dosage of the fast and slow mixing times, and the interaction of the fast and slow mixing times influenced the removal of turbidity, while the color removal was influenced by the optimum dosage and duration of slow mixing. The samples filtered in filter quantitative without unsightly porosity and were exposed to solar disinfection for removal of E. coli and total coliforms. There elimination 64.8 and 59.7% at 2 hours; 100% and 99.7% in 4 hours and 100% at 6 hours for unfiltered water. For filtered water removals were 70 and 19.2% (2 hours); 100 and 46% (4 hours) and 100% (6 h). Solar disinfection was more efficient in water exposure for 6 hours. It could be concluded that the joint use of the Moringa and solar disinfection generally promoted the clarification and disinfection of water, significantly reducing turbidity and leaving the water free of E. coli and total coliforms.
386

Contaminação microbiológica e avaliação de métodos de higienização de panos de limpeza utilizados em serviços de alimentação / Microbial contamination and evaluation of two disinfection methods of cleaning cloths used in food services

Bartz, Sabrina January 2008 (has links)
Panos de limpeza têm sido considerados importantes fontes de contaminação cruzada, contudo seu uso continua muito freqüente em serviços de alimentação. O objetivo desse trabalho foi avaliar a contaminação e multiplicação microbiana, além de dois procedimentos de higienização de panos de limpeza. Em uma primeira etapa, 35 panos de limpeza foram coletados em serviços de alimentação da grande Porto Alegre, RS/Brasil e foram submetidos à quantificação de bactérias totais, coliformes e Staphylococcus coagulase positiva, aqui chamado de Staphylococcus aureus presuntivos. Os panos foram lavados manualmente e desinfetados por dois métodos, separadamente: a) fervura em água potável por 15 minutos e b) imersão em solução clorada a 200ppm, por 15 minutos, sendo enxaguados logo após. Os resultados demonstraram que a as contagens de bactérias totais variaram de 2,0 x 104 UFC/cm2 até 1,0 x 108 UFC/cm2, com média de 9,1 x 106 UFC/cm2. A contaminação por coliformes foi de 4,4 x 102 a 1,6 x 107 UFC/cm2, sendo que 40% das amostras apresentou contagens de aproximadamente 106 UFC/cm2. Quantidades de S. aureus presuntivos variaram de 1,0 x 104 UFC/cm2 a 2,8 x 106 UFC/cm2, com média de 4,6 x 105 UFC/cm2. De modo geral, panos desinfetados pelos dois métodos demonstraram reduções significativas (p < 0,05) do número de microrganismos, as quais foram de aproximadamente 5 ciclos logarítmicos. Em uma segunda etapa, panos contendo diferentes quantidades de matéria orgânica (0%, 1%, 5% e 10% de albumina bovina) foram contaminados com Salmonella Enteritidis 3091/05, Escherichia coli ATCC 25972, Staphylococcus aureus ATCC 25923 e Shigella sonnei CC07 e incubados por 1h, 2h, 3h e 4h, a 30 oC. A multiplicação foi avaliada por métodos microbiológicos e por bioluminescência gerada por ATP. Uma bactéria recombinante, ampicilina-resistente (HSα E. coli) foi utilizada para avaliar o potencial de dispersão de panos. Os resultados demonstraram que até duas horas de incubação não houve multiplicação expressiva de todos os microrganismos avaliados, no entanto, em três horas a maioria apresentou leve aumento da população. Uma exceção foi a S. Enteritidis que apresentou multiplicação significativamente maior (p < 0,05). Após quatro horas de incubação, todos os microrganismos apresentaram multiplicação significativa. A bioluminescência confirmou esses resultados e também demonstrou que diferentes quantidades de matéria orgânica não interferiram na multiplicação microbiana nas primeiras 3 a 4 horas. O experimento da dispersão bacteriana demonstrou que um pano contaminado com 104 UFC/cm2 foi capaz de transferir aproximadamente 102 UFC/cm2 de bactérias para uma superfície de aço inoxidável. Baseado nesses resultados, pode-se concluir que panos de limpeza utilizados em serviços de alimentação apresentavam nível elevado de contaminação, porém se adequadamente lavados e desinfetados, suas contagens podem ser significativamente reduzidas. Além disso, sugere-se que panos adequadamente desinfetados sejam utilizados por aproximadamente duas horas, não ultrapassando o período de três horas. / Cleaning cloths have been considered as important cause of cross-contamination, however its use remains frequent in food services. The objective of this study was to evaluate microbial contamination and multiplication, as well as two disinfection methods of cleaning cloths. In a first step of this work, samples (n=35) were collected in food services of Porto Alegre City, RS/Brazil and quantified for microbial contamination. Results indicated total aerobic counts varying from 2.0 x 104 cfu/cm2 up to 1.0 x 108 cfu/cm2, with mean numbers of 9.1 x 106 cfu/cm2. Coliform contamination varied from 4.4 x 102 up to 1.6 x 107 cfu/cm2 per cloth, and 40 % of the samples presented counts around 106 cfu/cm2, while presumptive S. aureus ranged from 1.0 x 104 cfu/cm2 up to 2.8 x 106 cfu/cm2, with mean numbers of 4.6 x 105 cfu/cm2. The cleaning cloths were disinfected in boiling water for 15 minutes and with 200 ppm sodium hypochlorite solution for 15 minutes, separately, demonstrating significant reductions (p < 0.05) of approximately 5 log. In a second step of this study, cloths containing 0 %, 1 %, 5%, and 10% of organic matter (bovine albumin) were contaminated with Salmonella Enteritidis 3091/05, Escherichia coli ATCC 25972, Staphylococcus aureus ATCC 25923 and Shigella sonnei CC07, and were incubated for 1 h, 2 h, 3 h, and 4 h, at 30 oC. Microbial multiplication was evaluated by bacterial counts and ATP bioluminescence, and an ampicilin-resistant recombinant HSα E. coli was used as a pathogen surrogate to investigate the potential of microbial cloth dispersion. The results demonstrate that until 2 hours of storage all strains did not present expressive growth. In 3 hours of storage the majority of the microorganisms showed slightly development, being that S. Enteritidis grown significantly better than other strains. In 4 hours of incubation all microorganisms demonstrate significant growth (p < 0.05). ATP bioluminescence confirmed the microbial count results and also demonstrates that different amounts of organic matter did not interfere with the bacterial multiplication at the first 3 to 4 hours of incubation. The dispersion experiment indicated that a cleaning cloth contaminated with 104 cfu/cm2 was able to spread approximately 102 cfu/cm2 recombinant E. coli onto a stainless steel surface. Based on these results it was possible to conclude that cleaning cloths used in food services were very contaminated, however adequate sanitation procedures could reduce significantly its microbial contamination. We suggested that an appropriate period of time to use disinfected cleaning cloths is around 2 hours, not exceeding 3 hours of usage.
387

Eficácia de desinfetantes frente bactérias sobreviventes a higienização de equipamentos de matadouro-frigorífico de bovinos

Molina, Paulo Duran dos Santos January 2009 (has links)
Na indústria da carne, a eficaz desinfecção das superfícies de contato com o alimento é uma importante barreira sanitária para evitar que os microrganismos deteriorantes e potencialmente patogênicos degradem o alimento ou ponham em risco a saúde dos consumidores. Com objetivo de monitorar a atividade antimicrobiana, pelo teste de suspensão, os desinfetantes quaternário de amônio, ácido peracético, clorhexidina, iodofor e hipoclorito de sódio foram confrontados com Escherichia coli, Staphylococcus aureus e dois pools de bactérias, todos organismos sobreviventes à higienização de um matadouro-frigorífico de bovinos com alta capacidade de abate. Os desinfetantes foram diluídos em graus geométricos com fator 0,5 formando cinco concentrações. Usaram-se os tempos de contato 5, 10, 15 e 20 minutos, e para simular deficiência de limpeza, à solução desinfetante foi adicionada 1% de matéria orgânica na forma de soro bovino estéril. Para análise estatística foi realizada a análise da variância com distribuição binomial para variável resposta. Com o delineamento da investigação e os organismos indicadores usados, as menores concentrações/tempo de contato para inativação de todas as bactérias foram: quaternário de amônio 25 ppm/20min. e 50 ppm/5min., ácido peracético 6,25 ppm/10min. e 25 ppm/5min., clorhexidina 200 ppm/5min. e 12,5 ppm/15min., iodofor 50 ppm/5min. e hipoclorito de sódio 200 ppm/5min. Todos os desinfetantes avaliados podem ser usados para inativar as bactérias sobreviventes no matadouro-frigorífico. Por outro lado, a simulação indica que a manipulação in loco dos fatores concentração, tempo de contato e matéria orgânica, entre outros, podem permitir a sobrevivência dos microrganismos no ambiente. / In the meat-processing industry, the efficient disinfection of meat contact surfaces is an important sanitary barrier to avoid deteriorating and potentially pathogenic microorganisms degrading the meat or pose a health hazard to consumers. Aiming to monitor antimicrobial activity through suspension test, the disinfectants ammonium quaternary, peracetic acid, chlorhexidine, iodophor and sodium hipochlorite were confronted with Escherichia coli, Staphylococcus aureus and two bacterial pools, all surviving organisms to hygienization in a bovine slaughterhouse with high slaughtering capability. The disinfectants were diluted in geometric degrees with factor 0,5, compounding five concentrations. Contact times were 5, 10, 15 and 20 minutes and, in order to simulate cleanliness deficiency to the disinfecting solution, 1% of organic matter in the form of sterile bovine serum was added. For statistical analysis, a variance analysis was effectuated with binomial distribution to variable response. Through this investigative line and the aforementioned indicator organisms, the lesser concentration per contact time to inactivate all bacterial culture were: ammonium quaternary 25 ppm/20min and 50 ppm/5min.; peracetic acid 6,25 ppm/10min and 25 ppm/5min.; chlorhexidine 200 ppm/5min and 12,5 ppm/15min.; iodophor 50 ppm/5 min and sodium hipochlorite 200 ppm/5 contact minutes. All evaluated disinfectants can be utilized to inactivate surviving bacterial cultures in the slaughterhouse. On the other hand, the simulation indicates that the in loco manipulation of factors concentration, contact time and organic matter, besides others, can allow the microorganisms survival in the medium.
388

Influência da desinfecção de elastômeros com ácido paracético e água eletrolisada ácida / Influence of desinfection of elastomers with peracetic acid and acid electrolized water

Paulus, Marília January 2013 (has links)
O objetivo deste estudo foi avaliar a eficácia de duas soluções desinfetantes, ácido peracético e água eletrolisada ácida (AEA), na desinfecção de dois elastômeros, e a influência em suas propriedades de reprodução de detalhes e compatibilidade com o gesso. Um poliéter e uma silicona de adição foram manipulados, e a impressão de uma matriz apresentando três linhas (20, 50 e 75μm) de espessura e 25 mm de comprimento foi realizada. Após, os espécimes (n=3) foram imersos nas soluções de água destilada, glutaraldeído 2%, ácido peracético 0,2% e água eletrolisada ácida durante 10 minutos e, em seguida, o gesso tipo IV foi vazado sobre a impressão. Os materiais foram avaliados quanto à reprodução de detalhes e compatibilidade com o gesso. Posteriormente, biofilmes de Sthaphylococcus aureus foram cultivados sobre os espécimes durante 24 horas a 37°C. Após, os espécimes foram imersos durante 10 minutos nas soluções a seguir: solução salina estéril 0,89%, glutaraldeído 2%, ácido peracético 0,2% e água eletrolisada ácida. O biofilme presente em cada espécime foi coletado, diluído e alíquotas das diluições foram inoculadas em meio ágar sangue. Depois de 24 horas de incubação a 37°C, foi realizada a contagem do número de unidades formadoras de colônias bacterianas em cada um dos espécimes. Na reprodução de detalhes os resultados foram satisfatórios, pois a linha de 20 μm foi reproduzida em todos os espécimes. No teste de compatibilidade com o gesso, todos os grupos reproduziram a linha de 50 μm em todo o comprimento de 25 mm. Na análise antimicrobiana, os resultados mostraram que houve crescimento nos espécimes imersos em solução salina estéril (grupo controle negativo). Entretanto, não houve crescimento bacteriano nos espécimes imersos na solução de glutaraldeído 2%, ácido peracético 0,2% e AEA (p<0,001). Com base na metodologia realizada, concluiu-se que o ácido peracético e a água eletrolisada ácida não alteraram as propriedades dos elastômeros avaliados, e mostraram-se eficazes no processo de desinfecção destes materiais. / The aim of this study was to evaluate the efficacy of two disinfecting solutions (peracetic acid and acid electrolyzed water) in two elastomeric materials and the influence on its detail-reproduction properties and gypsum compatibility. Polyether and vinyl polysiloxane were handled, and impression of a metal mould with three lines (20, 50 and 75μm wide and 25mm long) was performed. After this, the impressions (n=3) were immersed in the following solutions, for 10 minutes: distilled water, glutaraldehyde 2%, peracetic acid 0,2% and acid electrolyzed water and then type IV gypsum was poured on the impression. The materials were evaluated as to detail reproduction the gypsum compatibility. Subsequently specimens were immersed for 10 minutes into the following solutions: 0.89% sterile saline solution, 2% glutaraldehide, 0.2% peracetic acid, and acid electrolyzed water. The biofilm in each sample was collected and diluted, and the aliquots of the dilution were inoculated in blood agar. After 24h incubation at 37°C, the colony forming units (CFU) were calculated. In the detail reproduction the results were satisfactory, as the 20 μm line was reproduced in all specimens. All specimens presented detail reproduction and gypsum compatibility after immersion. In the antimicrobial analysis, the results showed that the specimens immersed in sterile saline solution grew (negative control group). On the other hand, there was no bacterial growth in the specimens immersed in 2% glutaraldehyde, 0.2% paracetic acid, and acid electrolyzed water (p<0.001). Based on this study methodology, it is concluded that both peracetic acid and acid electrolyzed water did not influence the detail reproduction and gypsum compatibility were efficient in disinfecting the elastomeric materials.
389

Avaliação do efeito da desinfecção por agentes químicos e da irradiação gama no poli(3-hidroxibutirato)

SOUZA, Anailda Maria Pereira Lopes de 14 March 2016 (has links)
Submitted by Fabio Sobreira Campos da Costa (fabio.sobreira@ufpe.br) on 2017-04-25T13:55:38Z No. of bitstreams: 2 license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) dissertação CENTRAL FINAL.pdf: 2543250 bytes, checksum: b3adf9bd3291a6638da52621c387fab7 (MD5) / Made available in DSpace on 2017-04-25T13:55:38Z (GMT). No. of bitstreams: 2 license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) dissertação CENTRAL FINAL.pdf: 2543250 bytes, checksum: b3adf9bd3291a6638da52621c387fab7 (MD5) Previous issue date: 2016-03-14 / PRH-ANP/MCT / Muitos trabalhos vem norteando a utilização do poli(3-hidroxibutirato)-PHB, polímero da família dos Poli(hidroxialcanoatos), que possui como principais características, biodegradabilidade e biocompatibilidade, o que lhe permite aplicações na área médicohospitalar, médico-farmacêutica, embalagens alimentícias, entre outras. O estudo sobre a degradação de polímeros quando exposto a qualquer tipo de fonte degradativa é tema de grande interesse científico e industrial, em razão das alterações químicas que podem ocorrer na cadeia, podendo ocasionar a cisão (ou quebra) de ligações na cadeia principal ou em grupos laterais, reticulação, eliminação ou substituição de cadeias laterais, reações intramoleculares, auto-oxidação e despolimerização. A avaliação das propriedades do PHB após um processo de esterilização, ou mesmo da estabilidade desse material quando exposto a alguma substância química e/ou radiação gama é um importante tema de estudo pois é necessário adequar os materiais às normas, principalmente em aplicações como embalagem para uso médico hospitalar. Esse trabalho teve como objetivo avaliar a estabilidade à radiação gama do PHB, bem como investigar a estabilidade desse polímero quando imerso nas soluções de glutaraldeído 2% e etanol 70%. Os filmes de PHB foram preparados pela técnica de solution casting. Analisou-se amostras de filmes de PHB puro; PHB irradiados a 25 kGy; PHB imerso em glutaraldeído 2% irradiado 25 kGy e não irradiados com tempo de imersão na solução por 2, 4, 6 e 8 horas; PHB imerso em etanol 70% (EtOH) irradiado 25 kGy e não irradiados, com tempo de imersão na solução por 2, 4, 6 e 8 horas. As propriedades destes foram avaliadas a partir de diversas técnicas, tais como: infravermelho com transformada de Fourier (FTIR), ensaio de tração, calorimetria exploratória diferencial (DSC), termogravimetria (TGA). A partir das análises por componentes principais realizadas através dos espectros de infravermelho das amostras dos filmes de PHB puro, PHB imersos em glutaraldeído 2%, etanol 70% e, após exposição à radiação gama, apresentaram alterações químicas na sua estrutura, após exposição à radiação gama ou imersão nos agentes químicos estudados. Verificou-se, portanto, que o PHB é sensível à radiação gama, apresentando como efeito fundamental perdas de suas propriedades mecânicas, o que pode ser resultante do processo de cisão molecular. Contudo, em relação a esterilização do polímero com glutaraldeído e etanol, não se evidenciou perdas nas propriedades mecânicas das amostras imersas em ambas as soluções. Quanto às propriedades térmicas, amostras de PHB imersas em glutaraldeído 2% e etanol 70% apresentaram comportamento semelhante ao PHB puro. A degradação térmica dos filmes de PHB ocorreu em um único estágio e em uma faixa de temperatura que variou para a amostra PHB puro de 225,4 ºC a 295,1 ºC. O comportamento térmico das amostras de PHB imersas em glutaraldeído e etanol observado pelas curvas de TGA, antes e após processos de esterilização por radiação gama, foi semelhante ao comportamento térmico do filme de PHB puro. / A lot of study have conducted the use of poly (3-hydroxybutyrate)-PHB, a polymer from the poly (hydroxyalkanoates) family, which has main characteristics such as biodegradability and biocompatibility that allows applications in the medical-hospital, medical-pharmaceutical and food packaging areas. A study on polymer degradation when exposed to any type of degradative source is a subject of great scientific and industrial interest due to the chemical changes that may occur in the chain such as scission, crosslinking, elimination or substitution of side chains, intramolecular reactions, auto-oxidation and depolymerization. Sterilized PHB or even its stability when exposed to some chemical substance or gamma radiation, becomes important topics of study to fit the standards, especially in applications such as packaging for hospital-medical use. The objective of this work was to evaluate the PHB gamma radiation stability and to investigate the stability of this polymer when immersed in 2% glutaraldehyde and 70% ethanol solutions. PHB films were prepared by the technique of solution casting. The analyzed samples were: films of pure PHB; PHB irradiated at 25 kGy; PHB immersed in 2% glutaraldehyde irradiated 25 kGy and non-irradiated, with immersion time in the solution for 2, 4, 6 and 8 hours; PHB immersed in ethanol 70% (EtOH) irradiated 25 kGy and nonirradiated, with immersion time in the solution for 2, 4, 6 and 8 hours. Its properties were evaluated from several techniques such as: Fourier transform infrared (FTIR), tensile test, differential scanning calorimetry (DSC), thermogravimetry (TGA). Based on the analysis of the main components of different types of PHB samples (PHB immersed in 2% glutaraldehyde, 70% ethanol and after exposure to gamma radiation) showed chemical changes in structure, after exposure to gamma radiation or immersion in the chemical agents studied. It was verified that the PHB is sensitive to gamma radiation, presenting as fundamental effect losses of its mechanical properties, which may be the result of the molecular scission process. However, in relation to the sterilization of the polymer with glutaraldehyde and ethanol, no losses were observed in the mechanical properties of the samples immersed in both solutions. Regarding to the thermal properties PHB samples immersed in 2% glutaraldehyde and 70% ethanol presented similar behavior in comparison to pure PHB. The thermal degradation of PHB films occurred in a single stage and in a temperature range, which varied for the pure PHB sample from 225.4 ° C to 295.1 ° C. The thermal behavior of PHB samples immersed in glutaraldehyde and ethanol prior to and after gamma ray sterilization procedures observed by the TGA curves were similar to the thermal behavior of the pure PHB film.
390

Avaliação do dano morfológico em oocistos de Cryptosporidium spp. e cistos de Giardia spp. pela ação da peroxidação assistida por luz ultravioleta (H2O2/UV) / Evaluation of morphological damage in Cryptosporidium spp. oocysts and Giardia spp. cysts using peroxidation assisted by ultraviolet light (H2O2/UV) process

Fagnani, Regiane Aparecida Guadagnini, 1984- 16 August 2018 (has links)
Orientadores: José Roberto Guimarães, Regina Maura Bueno Franco / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil, Arquitetura e Urbanismo / Made available in DSpace on 2018-08-16T18:49:39Z (GMT). No. of bitstreams: 1 Fagnani_RegianeAparecidaGuadagnini_M.pdf: 1137415 bytes, checksum: 64844acd70b57a2326bc81078d609ced (MD5) Previous issue date: 2010 / Resumo: O objetivo deste trabalho foi inferir a eficiência do Processo Oxidativo Avançado (POA): H2O2/UV, na inativação de oocistos e cistos dos protozoários Cryptosporidium spp. e Giardia spp. respectivamente, em amostras de solução aquosa com características de água natural. Utilizaram-se concentrações de peróxido de hidrogênio de 15 mg L-1 e 6 g L-1 e dose de UV de 44 mW s cm-2 e 5.472 mW s cm-2, respectivamente. A eficiência do POA foi inferida a partir da avaliação do dano morfológico causado pelo processo na parede de oocistos e cistos, sendo observados pelo método de Reação de Imunofluorescência Direta (RID) e mediante Microscopia Eletrônica de Varredura (MEV). O POA foi mais eficiente em causar dano na parede de Giardia duodenalis e oocistos de Cryptosporidium spp. Usando a menor dose de UV e concentração de peróxido, o POA causou dano de forma e/ou fluorescência em 45,3 % dos cistos de G. duodenalis e em 61,9 % dos oocistos de Cryptosporidium spp. Entretanto quando utilizada a alta dose de UV e concentração de peróxido, somente dois oocistos Cryptosporidium spp. foram observados. Oocistos de Cryptosporidium spp. mostrou maior sensibilidade ao POA do que cistos de Giardia duodenalis / Abstract: The aim of this study was infered the efficiency of advanced oxidative processes (AOP): H2O2/UV in inactivation of oocysts and cysts of Cryptosporidium spp. and Giardia duodenalis respectively, in aqueous solution's samples with characteristics of natural water. It was used concentrations of hydrogen peroxide of 15 mg L-1 and 6 g L-1 and UV dose was of 44 mW s cm-2 and 5.472 mW s cm-2, respectively. Direct Immunofluorescence Antibody Assay (IFA) and Scanning Electron Microscopy (SEM) were used to evaluate oocysts and cysts walls damage caused by the process. The AOP was efficient in damage G. duodenalis cysts and Cryptosporidium spp. oocysts wall. Using a small dose of UV irradiation and concentrations of hydrogen peroxide, AOP caused damage oin the shape and/or alteration of fluorescence in 45.3 % cysts of G. duodenalis and 61.9 % oocysts of Cryptosporidium spp. However, when used higher UV dose and concentrations of hydrogen peroxide only two Cryptosporidium spp. oocysts were observed. Cryptosporidium spp. oocysts showed higher sensibility than cysts of G. duodenalis to the peroxidation assisted by ultraviolet light process / Mestrado / Saneamento e Ambiente / Mestre em Engenharia Civil

Page generated in 0.0673 seconds