• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 236
  • 230
  • 26
  • 19
  • 18
  • 15
  • 14
  • 10
  • 8
  • 7
  • 6
  • 3
  • 2
  • 2
  • 2
  • Tagged with
  • 674
  • 200
  • 199
  • 83
  • 81
  • 79
  • 73
  • 71
  • 63
  • 62
  • 54
  • 43
  • 42
  • 39
  • 37
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
461

Effect of amine-based water treatment polymers on the formation of N-nitrosodimethylamine (NDMA) disinfection by-product

Park, Sang Hyuck 17 January 2008 (has links)
In recent years, a compound N-nitrosodimethylamine (NDMA), a probable human carcinogen, has been identified as an emerging disinfection by-product (DBP) since its formation and detection were linked to chlorine-based disinfection processes in several water utilities in the U.S. and Canada. Numerous organic nitrogen compounds present in water may impact the formation of NDMA during disinfection. Amine-based water treatment polymers used as coagulants and flocculants have been suggested as potential NDMA precursors due to the presence of amine functional groups in their structures, as well as the possible presence of dimethylamine (DMA) residues in polymer products. To minimize the potential risk of NDMA associated with water treatment polymers, the mechanisms of how the polymers behave as NDMA precursors and their contribution to the overall NDMA formation under actual water treatment conditions need to be elucidated. This research involved a systematic investigation to determine whether amine-based water treatment polymers contribute to NDMA formation under drinking water and wastewater treatment conditions, to probe the involved reaction mechanisms, and to develop strategies to minimize the polymers NDMA formation potential. The investigation included five research tasks: (1) General screening of NDMA formation potential of commonly used amine-based water treatment polymers, (2) NDMA formation from amine-based water treatment polymers under relevant water treatment conditions, (3) Probing the mechanisms of NDMA formation from polyamine and PolyDADMAC, (4) Effect of water treatment processes on NDMA formation from amine-based water treatment polymers, and (5) Developing strategies to reduce polymers NDMA formation potential. Direct chloramination or chlorination of high doses of polymers in deionized water at longer than typical contact time was used in the general screening of the NDMA formation potential of water treatment polymers and in the studies to identify reaction mechanisms. On the other hand, realistic dosages of chloramines and polymers and contact time were used in simulating representative water treatment conditions to evaluate the contribution of polymers to the overall NDMA formation in real systems. On the basis of the study results, strategies were developed to reduce the NDMA formation potential of amine-based water treatment polymers, which include modification of polymer structures and treatment parameters.
462

Desinfecção de nível intermediário de endoscópio rígido por meio de limpeza prévia com detergente seguido de álcool etílico 70% p/v: protocolo operacional padrão / Disinfection of intermediate level of rigid endoscope through prior cleaning with detergent followed by ethyl alcohol 70% w/v: standard operating protocol

Marco César Jorge dos Santos 11 June 2018 (has links)
INTRODUÇÃO: A limpeza prévia de endoscópios rígidos (ER) seguida de desinfecção de nível intermediário com álcool etílico a 70% p/v após o exame de endoscopia nasal é uma prática adotada em muitos serviços de otorrinolaringologia. A literatura atual, no entanto, recomenda a esterilização ou desinfecção de alto nível como o método de descontaminação mais aceito para produtos para saúde classificados como semicríticos. No entanto, há que se fazer distinção entre equipamentos de alta complexidade e sua invasividade como os endoscópios flexíveis com lumens longos e estreitos utilizados na endoscopia digestiva, daqueles de conformação simples sem lumens de baixa invasividade como os endoscópios rígidos utilizados em otorrinolaringologia. OBJETIVO: Avaliar a segurança da desinfecção de nível intermediário com álcool etílico 70% p/v, após limpeza prévia dos endoscópios rígidos utilizados em procedimentos clínicos de endoscopia nasal considerando a carga microbiológica recuperada após o uso. MÉTODO: Imediatamente após a realização do exame, uma gaze úmida foi utilizada para o arraste da carga biológica do endoscópio rígido, gerando as amostras do Controle Positivo e, após a aplicação do POP, um novo arraste para constituir as amostras do Grupo Experimental. Estas gazes foram inicialmente submetidas à sonicação e agitação imersas em soro fisiológico e em seguida a solução foi submetida a uma técnica de extração de carga microbiológica por filtragem por meio de uma Membrana de Celulose de 0,22um de poro que foi, em seguida, semeada nos meios de ágar Sangue, Chocolate, Sabouraud, Löwenstein-Jensen e Tioglicolato. Estes meios ficaram incubados em estufa a 37ºC ± 2ºC e avaliados, no máximo, até por 60 dias conforme o perfil de crescimento dos diferentes microrganismos de interesse; foram analisados de maneira quantitativa e qualitativa para identificação e classificação dos micro-organismos recuperados após as semeaduras. RESULTADO: Os resultados da análise estatística evidenciaram diferença significativa entre Controle Positivo e Grupo Experimental quando comparados em relação à presença de Streptococcus coagulase negativa (p < 0,001), Bacillus spp (p < 0,001) e Staphylococcus aureus (p=0,001). No Controle Positivo, foram encontradas presença desses micro-organismos respectivamente na seguinte frequência: 63,2%, 28,9% e 28,9%, enquanto que, no Grupo Experimental, não foi houve recuperação microbiana alguma. CONCLUSÃO: Os resultados desta pesquisa demonstram a eficiência, na prática diária, da desinfecção de nível intermediário dos endoscópios utilizados na otorrinolaringologia por meio da fricção com álcool etílico 70% p/v por 90 segundos, com protocolo de limpeza prévia / INTRODUCTION: Prior cleaning of rigid endoscopes (REs) followed by intermediate-level disinfection with 70% ethyl alcohol (w/v) after nasal endoscopy is a common practice in many otolaryngology services. Current literature, in turn, recommends high-level sterilization or disinfection as the most accepted decontamination method for health products classified as semi-critical. However, it is necessary to distinguish highly complex equipment according to their invasiveness, e.g., flexible endoscopes with long and narrow lumens used in digestive endoscopy and those with a simple conformation without lumens of low invasiveness, such as rigid endoscopes used in otorhinolaryngology. OBJECTIVE: To evaluate the safety of intermediate-level disinfection with 70% ethyl alcohol (w/v) after cleaning of REs used in clinical procedures of nasal endoscopy considering the microbiological load recovered after use. METHOD: Immediately after the test, a wet gauze was used to drag the biological load from the RE, generating positive control samples; after applying POP, dragging was carried out again to generate samples of the experimental group. These gasses were initially subjected to sonication and shaking while immersed in physiological saline; the solution was then subjected to the microbiological loading technique by filtration through a 0.22-um pore cellulose membrane and then cultivated on blood, chocolate, Sabouraud, Löwenstein-Jensen, and thioglycolate agar media. These media were incubated at 37ºC ± 2ºC and evaluated for up to 60 days, according to the growth profile of the different microorganisms of interest. A quantitative and qualitative analysis was performed for the identification and classification of microorganisms recovered after cultivation. RESULTS: The results of statistical analysis showed a significant difference between the positive control and experimental groups for the presence of coagulase-negative Streptococcus (p < 0.001), Bacillus spp (p < 0.001), and Staphylococcus aureus (p=0.001). In the positive control group, these microorganisms were found in the following proportions: 63.2%, 28.9%, and 28.9%, respectively, whereas in the experimental group, no microorganisms were recovered. CONCLUSION: The results of this study demonstrate the efficiency of the daily practice of intermediate-level disinfection of endoscopes used in otorhinolaryngology by means of treatment with 70% ethyl alcohol (w/v) for 90 seconds, using a previous cleaning protocol
463

Inactivation bactérienne par photocatalyse hétérogène : application à Escherichia Coli / Bacterial inactivation by heterogeneous photocatalysis : applied to Escherichia Coli

Kacem, Majdi 07 July 2015 (has links)
L’étude présentée dans ce mémoire s’inscrit dans le cadre de la réutilisation des eaux usées traitées par un procédé d’oxydation avancée (AOP), la photocatalyse hétérogène. Ce procédé, couplant le rayonnement UV et l’utilisation d’un photocatalyseur (TiO2) au sein d’un réacteur, est envisagé comme procédé de traitement tertiaire pour la désinfection des effluents dis secondaires. Les expérimentations photocatalytiques ont été réalisées sur une bactérie cible, E.coli. Elles ont été conduites en mode batch puis en mode continu. Les expérimentations en mode batch ont été réalisées sous irradiation contrôlée puis solaire. Les données expérimentales acquises sous irradiation contrôlée ont permis la comparaison des performances bactéricides de différents catalyseurs. Elles ont conduit en parallèle à la définition d’un modèle cinétique représentatif de la capacité bactéricide de chaque média. Les expérimentations solaires ont permis de valider le modèle cinétique sous irradiation solaire puis, d’étudier l’inactivation bactérienne dans un effluent réel. Par ailleurs, le potentiel bactéricide du traitement photocatalytique en régime permanent a été évalué. Le fonctionnement du procédé continu a été parfaitement décrit par un modèle cinétique se basant sur la loi cinétique initialement définie en mode batch. Finalement, l’inactivation d’E.coli a été évaluée par différentes techniques de quantification bactérienne. Cela a permit de mettre en évidence le mécanisme principal d’inactivation par voie photocatalytique, la lyse membranaire et d’apporter des informations sur l’état de viabilité « réel » des bactéries au cours du traitement photocatalytique. / The study presented in this paper is part of the reuse of treated wastewater by advanced oxidation process (AOP), the heterogeneous photocatalysis. This process, coupling the UV radiation and the use of a photocatalyst (TiO2) in a reactor, is envisaged as tertiary treatment process for disinfection of said secondary effluent. Photocatalytic experiments were performed on a target bacterium, E. coli. They were conducted in batch and continuous mode. The experiments in batch mode were performed under controlled irradiation and sunlight. The experimental data obtained under controlled irradiation allowed the comparison of the bactericidal performance of different catalysts. They led in parallel to the definition of a representative kinetic model of the bactericidal capacity of each medium. Solar experiments were used to validate the kinetic model under solar irradiation and then to study the bacterial inactivation in a real effluent. Furthermore, the potential of the photocatalytic bactericidal treatment at steady state was evaluated. The operation of the continuous process has been thoroughly described by a kinetic model based on the kinetic law originally defined in batch mode. Finally, inactivation of E. coli was evaluated by different bacterial quantification techniques. This has made it possible to highlight the main mechanism of the photocatalytic bacterial inactivation, the membrane lysis. It provided information about the "real" state of the bacteria viability during the photocatalytic treatment.
464

[en] COOLING WATER TREATMENT USING HYDROGEN PEROXIDE / [pt] TRATAMENTO DE ÁGUAS DE RESFRIAMENTO COM PERÓXIDO DE HIDROGÊNIO

FERNANDO ANTONIO SERRAPIO PERES 24 August 2006 (has links)
[pt] O tratamento de águas de resfriamento normalmente é feito com a adição de cloro, porém este produto apresenta algumas desvantagens em sua aplicação. Como alternativa ao cloro, algumas indústrias no Brasil e no exterior estão começando a utilizar outros biocidas, dentre estes o peróxido de hidrogênio, um poderoso oxidante que apresenta forte ação biocida. O objetivo deste trabalho foi comparar a eficiência do cloro e do peróxido de hidrogênio como biocidas em diferentes condições, através de testes em água da torre de resfriamento de uma indústria siderúrgica localizada no Rio de Janeiro. A contaminação microbiológica desta água foi medida sem a adição dos biocidas e com a adição de cloro e peróxido de hidrogênio, permitindo assim comparar o desempenho destas substâncias no combate aos grupos bacterianos presentes na amostra. Foi realizado também um estudo sobre o efeito corrosivo destas substâncias através de testes de corrosão em aço carbono 1020, que permitiram avaliar a taxa de corrosão por perda de massa provocada pela aplicação destes produtos na água. Os resultados mostraram que o peróxido de hidrogênio possui uma ação biocida satisfatória para aplicações em águas de resfriamento. Foi constatado que o efeito biocida do peróxido de hidrogênio é mais limitado do que o cloro e que sua eficiência depende do tempo de contato e pode ser afetada pela presença de impurezas dissolvidas na água. Os ensaios de corrosão revelaram que o peróxido de hidrogênio provoca um efeito corrosivo comparável ao do cloro no material testado. / [en] Cooling water treatment generally is made with the addition of chlorine, although it´s application has some disadvantages. There is an active development in Brazil and other countries to use alternative chemical disinfectants in place of chlorine, such as hydrogen peroxide, a powerful oxidant which is known for its high biocidal efficiency. The aim of this research is to study the effectiveness of hydrogen peroxide as a disinfectant compared to chlorine in different operational conditions. The experiments were carried out using an water sample from a cooling water system of a steelmaking plant in the city of Rio de Janeiro. The microbial contamination of this water sample was measured without adding any kind of disinfectant. After that, water sample was treated by adding hydrogen peroxide and chlorine, in order to compare and evaluate the efficiency of the two biocides to control bacterial growth in water. Besides microbiological tests, experiments were conducted to compare the degree of corrosion caused by the addition of hydrogen peroxide and chlorine in water. The experimental methodology employed 1020 carbon steel specimens and corrosion rates were measured by weight loss determination after the period of exposure. The results showed that the application of hydrogen peroxide leads to satisfactory bacterial control. However, compared to chlorine, hydrogen peroxide is a rather poor disinfectant. The efficiency of hydrogen peroxide depends on reaction time and it is affected by dissolved polluants in water. Evaluation of corrosion rates showed that hydrogen peroxide causes basically the same corrosion rates than chlorine.
465

Efeito antimicrobiano das soluções desinfetantes sobre biofilmes de C. albicans em resinas acrílicas termopolimerizáveis / Antimicrobial effect of disinfectant solutions on C. albicans biofilms on heat-polymerized acrylic resins

Silva, Paulo Mauricio Batista da 24 March 2009 (has links)
As soluções desinfetantes têm sido empregadas como um dos principais métodos no controle de biofilmes microbianos, tais como os formados sobre a superfície de próteses totais. O objetivo desta pesquisa foi analisar o efeito antimicrobiano das soluções desinfetantes sobre biofilmes de C. albicans em resina acrílica termopolimerizável, por meio de microscopia confocal de varredura a laser, de cultura microbiológica e de microscopia eletrônica de varredura (MEV). Sessenta corpos-de-prova (5 x 5 x 1 mm) foram confeccionados, esterilizados e inoculados individualmente com C. albicans (1.107 cel/mL), aguardando-se 24 horas a 37°C para a formação do biofilme. A seguir, 24 corpos-de-prova foram divididos aleatoriamente em 4 grupos (n=6), de acordo com as soluções testadas: G1 (controle) água destilada por 10 minutos; G2 gluconato de clorexidina a 4% por 10 minutos; G3 hipoclorito de sódio a 1% por 10 minutos; G4 hipoclorito de sódio a 2% por 5 minutos. Após a desinfecção, os biofilmes remanescentes sobre os corpos-de-prova foram corados através dos fluorocromos SYTO-9 e iodeto de propídeo para análise no microscópio confocal. Ademais, 24 novos corpos-de-prova foram submetidos ao mesmo processo de desinfecção e destinados à análise através de cultura microbiológica. Após 48 horas de incubação, foi feita a contagem das unidades formadoras de colônia (UFC). Ainda, o mesmo processo de desinfecção foi utilizado para 12 novos corpos-de-prova para análise em MEV. Os dados foram analisados através do teste de Kruskal-Wallis, seguido do teste Student-Newman-Keuls, considerando um nível de significância de 5%. Os resultados obtidos pelo microscópio confocal demonstraram que todas as soluções desinfetantes promoveram a morte de todas as células fúngicas remanescentes sobre os corpos-de-prova. Resultado semelhante foi obtido através da análise por meio de cultura microbiológica, pois todas as soluções desinfetantes foram capazes de impedir o crescimento fúngico em cultura. Através da análise em microscópio confocal e em MEV, não foi observada remoção das células do biofilme fúngico sobre os corpos-de-prova pela solução de gluconato de clorexidina a 4%. Por outro lado, as soluções de hipoclorito a 1% e 2% promoveram uma remoção quase completa do biofilme fúngico da superfície dos corpos-de-prova. Além disso, através do MEV, alterações morfológicas foram observadas nas poucas células fúngicas remanescentes da desinfecção através de hipoclorito de sódio a 1%. Desse modo, a partir das condições experimentais deste estudo, pode-se considerar que as soluções de hipoclorito de sódio a 1% e 2% apresentaram um efeito antimicrobiano superior, quando comparados com a solução de gluconato de clorexidina a 4%. / Disinfectant solutions have been used as one of the principal methods to control microbial biofilms such as those formed on the complete denture surface. The aim of this study was to analyze the antimicrobial effect of disinfectant solutions on C. albicans biofilms on heat-polymerized acrylic resin by microbiological culture analysis, confocal laser scanning microscopy (CLSM) and scanning electron microscopy (SEM). Sixty specimens (5 x 5 x 1 mm) were fabricated, sterilized and individually inoculated with C. albicans (1.107 cells/mL) during 24 hours at 37°C to allow the biofilm formation. After that, these 24 specimens were randomly divided into 4 groups (n=6) according to the disinfection solutions tested: G1 (control) distilled water for 10 minutes; G2 4% chlorhexidine gluconate for 10 minutes; G3 1% sodium hypochlorite for 10 minutes; G4 2% sodium hypochlorite for 5 minutes. After disinfection, the remaining biofilms on the specimens were stained with fluorochromes SYTO-9 and propidium iodide to be analyzed by CLSM. Furthermore, the same disinfection process was applied to another 24 specimens which were submitted to microbiological culture analysis. After 48 hours of incubation, quantification of colony-forming units (CFU/mL) was performed. Also, the same disinfection process was applied to the remaining 12 specimens for the SEM analysis. The data were statistically analyzed using the Kruskal-Wallis and Student- Newman-Keuls tests, considering a significance level of 5%. The data obtained by CLSM revealed that all disinfectant solutions killed all remaining fungal cells on the specimens. Similar results were obtained by microbiological culture analysis, where all disinfectant solutions were able to avoid fungal growth in culture. CLSM and SEM analyses of specimens indicated that the 4% chlorhexidine gluconate solution did not remove the C. albicans cells from the resin acrylic surface. On the other hand, the 1% and 2% sodium hypochlorite solutions provided an almost complete biofilm removal from the acrylic surface. Furthermore, by SEM examination, morphologic damages became evident in the few residual Candida cells after 1% sodium hypochlorite disinfection. Thus, such findings suggest that, under the experimental conditions of this study, the 1% and 2% sodium hypochlorite solutions showed superior antimicrobials effect when compared with the 4% chlorhexidine gluconate solution.
466

Inativação de microrganismos indicadores presentes em efluentes secundários de esgoto sanitário com radiação ultravioleta / Inactivation of indicator microorganisms presents in secondary effluents of wastewater with ultraviolet radiation

Coletti, Fábio José 16 May 2003 (has links)
Nesta pesquisa estudou-se o emprego de radiação ultravioleta em reatores de batelada e em reator com escoamento contínuo (unidade comercial de alta intensidade), respectivamente em escala de laboratório e real. Os ensaios em batelada tiveram como finalidade monitoramento da potência radiante da lâmpada de baixa pressão de vapor de mercúrio durante a vida útil, determinação da intensidade média de radiação ultravioleta incidente no interior da câmara de desinfecção, obtenção dos coeficientes do modelo de Hom para coliformes totais, Escherichia coli e Clostridium perfringens e comparação da resistência à desinfecção desses microrganismos indicadores e colifagos. Os ensaios em sistema contínuo apresentaram como principal objetivo estudo da resistência dos microrganismos indicadores à desinfecção em condições de operação em escala real. Nos ensaios de desinfecção utilizou-se esgoto sanitário tratado em nível secundário. Os microrganismos indicadores apresentaram a seguinte ordem decrescente de resistência à desinfecção: C. perfringens, coliformes totais, E. coli e colifagos. As percentagens de inativação de C. perfringens, coliformes totais, E. coli e colifagos nos ensaios em batelada variaram de 0 a 99,882%, 36,3 a 99,999%, 21,8 a 100% e de 86,5 a 100%, respectivamente. Os resultados de inativação obtidos para coliformes totais e E. coli apresentaram ajustes pelo modelo de Hom com valores de R2 superiores a 0,81 e 0,76, respectivamente. Comprovou-se que a instalação contínua é inadequada para efluentes com elevadas concentrações de sólidos em suspensão e matéria orgânica. / In this research the use of ultraviolet radiation was studied in batch and continuous flow (high intensity commercial unit) reactors, respectively in laboratory and real scale. The batch assays were aimed to monitor the wattage of the low-pressure mercury lamp during its lifetime, to determine the mean ultraviolet radiation intensity inside disinfection chamber, to obtain Hom model coefficients for total coliforms, Escherichia coli and Clostridium perfringens and to compare the resistance to disinfection of these indicator microorganisms and coliphages. The assays in the continuous system presented as main objective to study the resistance of these indicator microorganisms to disinfection in real scale operational conditions. In the disinfection assays wastewater treated by a secondary level was used. The indicator microorganisms presented the following decreasing order of disinfection resistance: C. perfringens, total coliforms, E. coli and coliphages. C. perfringens, total coliforms, E. coli and coliphages inactivation percentages in batch assays varied from 0 to 99,882%, 36,3 to 99,999%, 21,8 to 100% and from 86,5 to 100%, respectively. The inactivation results obtained for total coliforms and E. coli presented adjustments by Hom model with R2 values above 0,81 and 0,76, respectively. It was proved that the installation of high intensity is not adequate for effluents with high concentration of suspended solids and organic matter.
467

"Desinfecção da Dentina Radicular pela Irradiação dos Lasers de Nd: YAG e Er: YAG: um Modelo "in vitro"" / Disinfection of intracanal dentin by ND:YAG, HO:YAG and ER:YAG laser irradiation: an in vitro model

Cecchini, Silvia Cristina Mafra 05 July 2001 (has links)
RESUMO Desinfecção da dentina radicular pela irradiação dos lasers de ND:YAG, HO:YAG e ER:YAG: um modelo in vitro A provável causa do insucesso da terapia endodôntica é a persistência de microrganismos colonizando os túbulos dentinários. Para reduzir o risco de insucesso e, se possível, o tempo despendido no tratamento endodôntico, novos equipamentos e materiais são constantemente desenvolvidos. O objetivo desta investigação foi estudar o efeito da irradiação laser intracanal na desinfecção dos túbulos dentinários de dentes bovinos recém-extraídos, utilizando-se um modelo in vitro. Os grupos irradiados pelos vários lasers foram comparados ao tratamento com hidróxido de cálcio, freqüentemente utilizado como medicação intracanal. O cemento radicular foi removido, o canal preparado e os dentes, cortados, resultando em 180 corpos de prova padronizados. Para promover a colonização bacteriana, os corpos de prova foram incubados, a 37 o C, em frascos contendo caldo de tripticase de soja e Enterococcus faecalis, o qual continha um plasmídeo que permitiu o seu crescimento em um meio seletivo com cloranfenicol. Os corpos de prova foram divididos em cinco grupos experimentais e três grupos-controle. Para irradiação foram utilizados os lasers pulsados de: Ho:YAG a 2,1 µm; Nd:YAG (1,06 µm); e Er:YAG (2,94 µm) com e sem refrigeração ar/água. Os grupos tratados receberam três parâmetros diferentes de irradiação com cada tipo de laser: energia abaixo do limiar de modificação física (physical modification threshold - ½ do PMT) por 60s; no limiar (PMT) por 60s; e, acima do limiar (120s). O Grupo 5 recebeu sete dias de tratamento com hidróxido de cálcio. Como controles, três espécimes para cada grupo receberam água estéril (controle negativo), três receberam KI3, após exposição à bactéria (controle negativo) e três não receberam tratamento após exposição à bactéria (controle positivo). A quantidade de bactérias foi estimada mediante a contagem de unidades formadoras de colônias (u.f.c.). De modo a avaliar, paralelamente, se os comprimentos de onda laser utilizados no experimento poderiam ser absorvidos pelo E. faecalis, foram obtidos espectros de absorção no UV, VIS e IR, por meio de espectroscopia. A análise estatística mostrou uma redução bacteriana como segue: Ho:YAG > hidróxido de cálcio > Nd:YAG > Er:YAG com refrigeração ar/água > Er:YAG sem refrigeração ar/água. Houve uma significativa redução bacteriana no grupo irradiado pelo Ho:YAG no limiar de modificação – PMT (50 mJ, 10 Hz, 66 J/cm 2 , por 120s), seguida pelo Ho:YAG a 50 mJ, 10 Hz, 33J/cm 2 , por 60s e pelo grupo que recebeu hidróxido de cálcio. Os dois últimos grupos não apresentaram diferenças estatísticas significativas. O espectro de absorção pelas bactérias (E. faecalis) nas faixas dos comprimentos de onda do UV e VIS apresentou picos de absorção em 361 nm e em 377 nm (UV). Já o infravermelho próximo revelou uma baixa absorção pelo microrganismo testado. / SUMMARY Disinfection of intracanal dentin by Nd:YAG, Ho:YAG and Er:YAG laser irradiation: an in vitro model A possible cause for root canal failure is the persistence of bacteria that have colonized dentinal tubules. To reduce this risk and, if possible, to also shorten the time-consuming endodontic therapy, new equipment and materials are constantly being introduced. The aim of the present investigation was to study the effect of disinfection of dentinal tubules by intracanal laser irradiation using an in vitro model. The groups irradiated by various lasers were compared with calcium hydroxide, a material frequently used as intracanal medication between appointments. Freshly extracted, intact bovine incisors were used. The root cementum was removed and the teeth cut to produce 180 standardized specimens. For bacterial colonization, specimens were incubated at 37 o C in test tubes with Tryptic Soy Broth and Enterococcus faecalis, which carried a plasmid that allowed the growth in a selective medium containing chloramphenicol. The specimens were divided in five treatment groups and three control groups. For irradiation, pulsed delivered Ho:YAG laser at 2.1 µm, Nd:YAG laser (1.06 µm), and Er:YAG and Er:YAG laser (2.94µm) with and without air/water coolant, were used. Lasers groups received three different laser settings for treatment: output energy below the physical modification threshold (½ of PMT) for 60 sec, at the PMT for 60 sec and above the PMT (120 sec). Group 5 received a seven-day treatment with calcium hydroxide. As controls, three specimens for each treatment group received sterile water instead of bacteria (negative control), three received iodine potassium-iodide after bacterial exposure (negative control), and three did not receive treatment after bacterial exposure (positive control). The number of bacteria was estimated by counting CFU. In order to evaluate whether the lasers used in the experiment could be absorbed by the bacteria E. faecalis, an UV, VIS and NIR spectra were obtained using a spectrophotometer. Statistical analysis showed the bacterial reduction as follow: Ho:YAG laser > hidróxido de cálcio> Nd:YAG laser > Er:YAG laser with air/water coolant > Er:YAG laser without air/water coolant. There was a significantly higher bacterial reduction in the group irradiated by the Ho:YAG at the PMT (50mJ, 10 Hz, 66 J/cm 2 for 120 sec), followed by Ho:YAG irradiated at 50mJ, 10 Hz, 33 J/cm 2 for 60 sec, and the group that received calcium hydroxide. The latter two groups were not significantly different. The UV and VIS absorbance spectrum presented two absorbance peaks at 361nm and 337nm (UV). The NIR spectrum revealed a very low absorbance by the E. faecalis.
468

Comparação da eficácia antibacteriana do álcool 70% (p/v) sobre superfície da câmara escura portátil com e sem limpeza prévia: um estudo experimental laboratorial / Comparison of the antibacterial efficacy of the alcohol 70% (w/v) over portable darkroom surfaces through rubbing, with and without previous cleaning processes: a laboratorial and experimental study

Graziano, Maurício Uchikawa 09 August 2011 (has links)
No contexto da prevenção da infecção cruzada na radiologia odontológica, superfícies que entram em contato direto com as mãos dos profissionais, como as superfícies da câmara escura portátil, devem ser descontaminadas. A recomendação clássica da descontaminação com álcool 70% p/v após limpeza prévia, nem sempre é seguida justificada pela não praticidade, acrescida do tempo curto disponível entre um atendimento e outro, limitando-se à aplicação direta do álcool o que, a priori, contraria as Boas Práticas de Controle de Infecção. A presente investigação, de caráter experimental laboratorial, controlado, randomizado e unicegado, teve como objetivo avaliar comparativamente a eficácia desinfetante do álcool 70% (p/v) sob fricção, com e sem limpeza prévia nas superfícies de câmaras escuras portáteis como procedimento de limpeza/desinfecção concorrente em radiologia odontológica. Três grupos de estudo foram constituídos: Grupo controle: superfícies previamente contaminadas com desafio (micro-organismo teste Serratia marcescens ATCC 14756, acrescido de 10% de saliva humana), submetidas à limpeza clássica por meio de água e detergente sob fricção, e posterior enxágue e consecutivamente, desinfecção com aplicação do álcool 70% p/v. Grupo experimental: superfícies previamente contaminadas com desafio, à semelhança do grupo controle, submetidas à aplicação direta do álcool 70% p/v sob fricção, SEM limpeza prévia. Grupo controle positivo: superfícies contaminadas com desafio. O tamanho amostral para os grupos experimental e controle foi de 85 unidades. Os experimentos foram realizados no Laboratório de Ensaios Microbiológicos do Departamento de Enfermagem Médico-Cirúrgica da Escola de Enfermagem da Universidade de São Paulo. Após o procedimento de contaminação, desafio da área superior da câmara escura portátil e sua posterior secagem, no grupo experimental a superfície foi diretamente friccionada com álcool 70% (p/v) durante 30 segundos. No grupo controle, o mesmo procedimento foi realizado, após a limpeza prévia. Imediatamente, após a evaporação do álcool da superfície, foi realizada a coleta microbiológica por meio da fricção com swab. Em seguida, a ponta do swab foi quebrada e mergulhada em um tubo de ensaio esterilizado com 1 mL de SF e agitado em Votex® por 30 segundos, intermitente e todo o conteúdo do tubo de ensaio foi vertido no centro de uma placa de Petri e, sobre ele, derramados 15 a 20 mL do meio Trypticase Soy Agar à temperatura aproximada de 30ºC. As placas foram deixadas na posição invertida, em ambiente à temperatura aproximada de 22ºC por 72 horas, com leitura diária da recuperação das UFC da Serratia marcescens. O controle positivo foi colhido da mesma forma que o dos Grupos Controle e Experimental, porém sem a aplicação de métodos para descontaminação. As médias das UFC foram comparadas entre os grupos experimental e controle, por meio do teste estatístico t de Student. Os resultados permitiram concluir que o álcool 70% p/v, quando aplicado diretamente sobre a superfície contaminada com matéria orgânica sob fricção, é um desinfetante eficaz, comprovado pela redução de seis logaritmos da população microbiana intencionalmente desafiada nos experimentos, não diferindo da redução observada no grupo controle (p=0,440). Estes achados permitiram atestar a segurança desta prática na limpeza/desinfecção concorrente durante as práticas de radiologia odontológica. / Aiming to avoid cross infection in the context of dental radiology, surfaces that get in direct contact with the hands of the professionals involved in dental procedures are ought to be decontaminated, such as the portable darkroom surfaces. The classical recommendation for the alcohol 70% w/v decontamination (which requires previous cleaning process) is not always applied due to its lack of practicality in addition to the short amount of time between dental procedures; so the decontamination is restricted only to the application of alcohol contradicting then, a priori, the good Practices of Infection Control. This investigation, which was conducted following laboratorial and experimental character, controlled, randomized and blinded, has had as its aim: evaluating comparatively the disinfecting efficacy of rubbing the surfaces of portable darkrooms with 70% w/v alcohol, with and without previous cleaning processes, as an alternative procedure for cleaning/disinfection in dental radiology. Three study groups were established: Control Group: previously contaminated surfaces with the worst case contaminant (test microorganism Serratia marcescens ATCC 14756 added to 10% of human saliva) firstly, traditionally cleaned by rubbing with water and detergent, rinsed afterwards then decontaminated using alcohol 70% w/v; Experimental Group: previously contaminated surfaces with the worst case contaminant similarly to Control Groups sample, however submitted straight away to the decontamination by rubbing with alcohol 70% w/v, with NO previous cleaning processes; Positive control Group: surfaces contaminated with the worst case contaminant. The sampling for both, the experimental and control groups, was 85 units. The experiments were conducted at the Microbiology Laboratory of the Medical-Surgical Nursing Department of the University of Sao Paulos Nursing School. After the worst case contamination procedure of the portable darkrooms upper area and drying, at the experimental group: the surface was directly rubbed with alcohol 70% w/v for thirty seconds. At the control group, the same procedure was performed, however, with previous cleaning following the traditional processes. Immediately after the alcohols evaporation from the surface, a microbiological collection was performed by swab friction. Afterwards, the swabs tip was broken and put in a sterile test-tube with 1mL of sterile saline solution and shaken in Vortex® for thirty seconds, and all its content poured into a Petri dish. Fifteen to 20 mL of Trypticase Soy Agar at approximately 30ºC was poured over the Petri dish. The dishes were left inverted, in an acclimatized environment (approximately at 22ºC) for 72 hours, with daily assessment of the Serratia marcescens CFUs (Colony-forming unit) growths. The positive control was collected following the same procedure as the other groups (control and experimental), with no decontamination methods applied. The CFU levels were compared between the Control and Experimental groups, regarding the statistic test of the t test of Student. The results allowed concluding that the alcohol 70% w/v rubbing, when applied straight to the contaminated surface, is an efficient disinfection method, proved by the 6 logs reduction of the worst case bacterial population; no different from the reduction observed at the control group (p=0,440 test t of Student). These results allow attesting and ratifying the safety of this alternative cleaning/disinfection processes in the context of dental radiology.
469

Efeito de soluções higienizadoras na retenção de cápsulas do tipo o\'ring / Effect of denture cleansers on the retention of capsules type o-ring

Pacheco, Thereza Cristina Lira 04 September 2015 (has links)
Soluções higienizadoras podem acarretar efeitos prejudiciais para as próteses, como deterioração da base da prótese e pigmentação. Porém, pouco se conhece sobre os efeitos destas na vida útil dos sistemas de retenção de uma overdenture. Deste modo, este estudo buscou avaliar se imersões diárias em clorexidina 2%, hipoclorito de sódio 1%, Corega® Tabs e água (controle) poderia acelerar a perda de retenção em attachments do tipo o´ring (S.I.N sistema de implantes®). Foram confeccionados 40 corpos de prova contendo cápsulas com anéis de borracha, simulando uma overdenture, e apenas 01 contendo o implante com o pilar o´ring. Eles foram separados em quatro grupos (n=10) e simulados noventa dias de imersões. Após, foram realizados testes de resistência à tração em uma máquina de ensaios mecânicos (MTS 810), antes e após a ciclagem com 270 ciclos, equivalentes a remoção e inserção da prótese três vezes ao dia, durante um período de três meses. Os resultados foram avaliados estatisticamente através dos testes ANOVA a dois critérios e do teste de Tukey (p&#x2264;0.05). Os valores médios (Newton) encontrados antes e após a imersão foram, respectivamente: Água - 9,482 / 6,081; Clorexidina - 9,972 / 7,390; Hipoclorito: 6,954 / 6,265 e Corega® Tabs: 12,464 / 11,121. Entre os grupos Clorexidina, Hipoclorito de sódio e Água não houve diferenças significativas. Houve diferenças estatisticamente significativas entre o grupo Corega® Tabs e os grupos controle e Hipoclorito de sódio, mas não com a Clorexidina. Assim, pôde-se concluir que soluções higienizadoras tiveram efeitos significativos na capacidade de retenção dos o´rings após o período simulado de três meses de imersão. / Denture cleansers can cause adverse effects on the prostheses, as deterioration of the denture base and pigmentation. However, little is known about its impacts on the life of an overdenture retention systems. Thus, this study sought to evaluate whether daily immersion in chlorhexidine 2%, sodium hypochlorite 1%, Corega® Tabs and water (control) would increase the retention loss in the O-ring type attachments (SIN implantes® system). Forty specimens containing capsules were made with rubber rings, simulating an overdenture, and only one containing the implant with the O-ring abutment. They were divided into four groups (n = 10) and ninety days in immersion were simulated, thereafter, conducted tensile strength tests on a testing machine (MTS - 810) before and after cycling of 270 cycles, equivalent to removal and insertion of the prosthesis three times a day for a period of three months. The results were statistically evaluated by the ANOVA two criteria and the Tukey test (p&#x2264;0.05). The mean values (Newton) found before and after immersion were: Water - 9,482 / 6,081; Chlorhexidine - 9,972 / 7,390; Hypochlorite: 6,954 / 6,265 and Corega® Tabs: 12.464 / 11.121. Among the groups chlorhexidine, sodium hypochlorite and water there were no significant differences. There were statistically significant differences between the group Corega® Tabs and controls and sodium hypochlorite groups, but not with the chlorhexidine. Thus, it concluded that denture cleansers had significant effects on retention capacity of orings after the simulated period of three months of immersion.
470

Determinação da atividade antimicrobiana de duas técnicas de antissepsia cutânea utilizadas em doadores de sangue / Determination of antimicrobial activity of two skin disinfection technique used in blood donors

Celere, Marina Smidt 24 March 2011 (has links)
No presente foi avaliado a atividade antimicrobiana de duas técnicas de antissepsia cutânea utilizadas rotineiramente em doadores de sangue em um serviço de Hemoterapia na cidade de Ribeirão Preto. Esse estudo teve como objetivo principal, estabelecer e comparar o percentual de redução microbiana em 50 doadores de sangue antes e após a aplicação de duas técnicas de antissepsia cutânea. Em cada braço do doador foi aplicado uma técnica de antissepsia, na primeira técnica utilizou-se o Polivinilpirrolidona-iodo (PVPI) degermante a 10% em movimentos de descida e subida por 30 segundos combinado com o PVPI a 10% em movimento circular único do centro para a periferia aplicados 30 segundos antes da punção venosa. Na segunda técnica foi utilizada solução de digluconato de clorexidina alcoólica a 0,5% em movimentos de descida e subida por 30 segundos e esperado secar por mais 30 segundos para a posterior punção venosa. Foram coletados swabs cutâneos no local da punção antes e após a aplicação de ambas as técnicas de antissepsia. Os swabs foram semeados em meio de cultura Ágar Sangue, Ágar Manitol Salgado e Ágar Mac Conkey e colocados em estufa à 37ºC por um período de 48 horas. Após esse período, foi realizada a contagem das colônias que cresceram nos meios de cultura. A técnica com PVPI a 10% obteve um percentual médio de redução microbiana de 98,57% no meio de cultura Ágar Sangue, 98,87% no meio de cultura Ágar Manitol Salgado e 100% no meio Mac Conkey. Já a técnica com clorexidina a 0,5% obteve percentual médio de redução microbiana de 94,38% no meio de cultura Ágar Sangue, 95,06% no meio Ágar Manitol Salgado e 100% no meio de cultura Mac Conkey. As análises estatísticas evidenciam que a técnica com PVPI a 10% obteve maior redução microbiana, sendo considerada, no presente estudo, mais eficaz que a Técnica com clorexidina a 0,5%. / In this study were evaluated the antimicrobial activity of two technique of skin antisepsis routinely used in blood donors in a transfusion service in the city of Ribeirão Preto. This study had as main objective, to determine and compare the percentage of bacterial reduction in 50 blood donors before and after application of two methods of skin antisepsis. In each arm of the donor was applied a technique of antisepsis, the first technique used the Polyvinylpyrrolidone-iodine (PVPI) degermant 10% in ascending and descending movements for 30 seconds combined with PVPI alcohol 10% in one circular motion from center to periphery applied 30 seconds prior to venipuncture. The second technique was used chlorhexidine gluconate solution 0.5% alcohol in ascending and descending movements for 30 seconds and waited for another 30 seconds to dry for later venipuncture. Skin swabs were collected at the puncture site before and after application of both techniques of antisepsis. The swabs were seeded in culture Blood Agar, Mannitol Salt Agar and MacConkey agar and placed in an oven at 37°C for a period of 48 hours. After this period, counts were performed in the colonies that grew in culture. The technique with PVPI 10% had an average rate of microbial reduction of 98.57% in the culture medium Blood Agar, 98.87% in the culture medium Mannitol Salt Agar and 100% in Mac Conkey medium. Since the technique with chlorhexidine 0.5% Total average percentage of bacterial reduction of 94.38% in the culture medium Blood Agar, 95.06% in the middle Salt Mannitol Agar and 100% in Mac Conkey medium. Statistical analysis showed that the technique with PVPI 10% was greater than bacterial reduction being considered in the present study, the most effective technique with chlorhexidine 0.5%.

Page generated in 0.3003 seconds