• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 6463
  • 104
  • 102
  • 101
  • 87
  • 78
  • 71
  • 57
  • 29
  • 11
  • 10
  • 10
  • 7
  • 4
  • 4
  • Tagged with
  • 6720
  • 3516
  • 1353
  • 889
  • 877
  • 836
  • 783
  • 730
  • 691
  • 616
  • 596
  • 569
  • 514
  • 473
  • 410
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
251

Desenvolvimento de um simulador virtual de vazamento para testar correlacionadores acústicos comerciais

Lima, Fábio Kroll de [UNESP] 09 December 2014 (has links) (PDF)
Made available in DSpace on 2015-06-17T19:33:44Z (GMT). No. of bitstreams: 0 Previous issue date: 2014-12-09. Added 1 bitstream(s) on 2015-06-18T12:48:07Z : No. of bitstreams: 1 000830129.pdf: 1160653 bytes, checksum: 208eaf9a5e0179c424cd0aaf5d1ee860 (MD5) / Vazamento em tubulações é uma das principais preocupações de empresas fornecedoras de água, devido à escassez e disponibilidade de fontes de água potável, principalmente em grandes cidades. A técnica de correlação cruzada tem sido bastante utilizada nos últimos 30 anos na localização de vazamentos em tubulações metálicas. Entretanto, o método de correlação cruzada não tem a mesma eficácia na detecção de vazamentos em tubulações plásticas, devido ao elevado nível de atenuação entre a parede da tubulação e o fluido, que rapidamente suprimem o sinal de vazamento. Por isso, o sinal de vazamento não consegue percorrer longas distâncias em tais tipos de tubulações. Sabe-se que, a faixa de frequência na qual a energia do vazamento está localizada é baixa, consequentemente o sinal de vazamento é facilmente afetado pelo ruído de fundo. Para evitar esta interferência, o filtro passa-banda é utilizado para suprimir o ruído indesejado antes de aplicar a técnica de correlação cruzada. A escolha das frequências apropriadas a serem utilizadas no filtro passa-baixa são fundamentais para obtenção de uma estimativa de tempo de atraso confiável entre dois sinais de vazamento, este tempo de atraso é utilizado para calcular a posição do vazamento. Este trabalho tem como objetivo à investigação e criação de um simulador de vazamento, aqui chamado de Simulador Virtual de Vazamento, através da utilização de um modelo analítico de vazamento em conjunto com atuadores mecânicos (caixas de som). Este simulador de vazamento poderá ser utilizado para avaliar correlacionadores comerciais e para fins de treinamento. A principal vantagem deste método é o controle de todo o experimento, de modo que a característica do sinal de vazamento simulado é conhecida previamente / Leak in pipes is one of the main concerns of water companies due to the scarcity and availability of potable water sources, especially in big cities. The cross-correlation technique has been used in the past 30 years to locate leaks in metallic pipes. Although the cross- correlation method works very well for metallic pipes, it does not have the same effectiveness in plastic pipes. This is mainly due to the high attenuation between the pipe wall and the fluid, which suppress rapidly the leak noise. Hence, leak noise does not travel long distance in such pipes. Moreover, the frequency range over which the leak energy is located, is at low frequency. Hence, the leak signal is easily affected by background noise. To avoid these problems, a band-pass filter is used to suppress undesirable noise before conducting the correlation. The selection of the band-pass filter limits is the key to have a reliable time delay estimate between two leak signals, which is used to calculate the position of a suspected leak. This work concerns the investigation and design of a leak simulator, here named Virtual Pipe Rig, using an analytical leak model together with mechanical actuators (shakers). The analytical model is responsible for generating leak signals used to drive the mechanical actuators, which are responsible for simulating the measure positions. This virtual pipe rig can be used to assess commercial correlators and training purposes. The main advantage of this method is the entire control of the experiment, so that the characteristic of the simulated leak signal is known beforehand
252

Ocorrência de nitrato nas águas subterrâneas do Sistema Aquífero Bauru em áreas rurais

Moura, Cinthia Cristine de [UNESP] 04 September 2014 (has links) (PDF)
Made available in DSpace on 2015-06-17T19:34:02Z (GMT). No. of bitstreams: 0 Previous issue date: 2014-09-04. Added 1 bitstream(s) on 2015-06-18T12:47:34Z : No. of bitstreams: 1 000830098.pdf: 6496495 bytes, checksum: 282930f6ea9f6b3bcefcc5ab7d68d589 (MD5) / O Sistema Aquífero Bauru (SAB) representa o mais importante aquífero na porção oeste do estado de São Paulo, constituindo uma excelente opção para o abastecimento de propriedades rurais. O acompanhamento da qualidade das águas subterrâneas no estado, realizado pela CETESB, vem apontando aumento nas concentrações de nitrato no SAB. Inúmeros estudos relacionam atividades agrícolas com a contaminação por nitrato de águas subterrâneas, em diversas partes do globo, entretanto em áreas rurais no território paulista não se conhece a extensão desse problema, o que motivou a realização desse estudo. O objetivo principal do trabalho foi o de avaliar as concentrações de nitrato nas águas subterrâneas do SAB, em áreas rurais dos municípios de São José do Rio Preto e Bauru. As atividades compreenderam o cadastro de poços, coleta de água subterrânea para análise química, tratamento estatístico dos dados hidroquímicos e avaliação das possíveis relações entre as concentrações de nitrato observadas e os tipos de atividades agrícolas desenvolvidas nas propriedades rurais. Foram realizadas duas campanhas de amostragem, e das amostras coletadas em São José do Rio Preto, em duas foram encontradas concentrações de nitrato superiores aos limites de potabilidade estabelecidos pela portaria MS 2914/11, enquanto em Bauru, três amostras na primeira campanha e em duas na segunda campanha, apresentam concentrações de nitrato superiores ao limite estabelecido. Entretanto, indícios de contaminação foram observados em diversas amostras, especialmente nas propriedades onde são desenvolvidas apenas atividades pecuária e atividades agrícolas associadas à pecuária (mistas), sugerindo que as maiores fontes de nitrato são oriundas de saneamento in situ e/ou disposição inadequada de dejetos animais, geralmente associadas a águas com maiores salinidades. Nas propriedades agrícolas, que apresentam águas menos... / The Bauru Aquifer System (BAS) represents the most important aquifer in the western portion of the state of São Paulo, which is an excellent option for supplying water for rural properties. Monitoring of groundwater quality in the state of São Paulo, carried out by CETESB, has observed an increase in nitrate concentrations in BAS's groundwater. In many parts of the world, studies linked agricultural activities with nitrate contamination of groundwater, while in São Paulo state the extension of nitrate contamination still unknown, which has motivated the development of this research project. The main purpose of this study is to evaluate the concentrations of nitrate in BAS's groundwater beneath rural zone in the city of São José do Rio Preto and Bauru. Activities carried out include record of wells and economic activity in the farms, groundwater sampling for chemical analysis, statistical treatment of hydrochemical data and evaluation of the possible relations between observed nitrate concentrations and the activities developed in the propriety. Nitrate concentration higher than the limit for drinking water quality established by the Brazilian authorities (MS2914/2011) has observed only in two samples in São do Rio Preto for both campaigns and in three samples collected in the first campaign and two samples collected in the second campaign, in Bauru. Meanwhile evidences of nitrate contamination were detected in several samples, especially in properties where are developed just livestock and agricultural activities associated with livestock (mixed), suggesting that the major sources of nitrate are from in-situ sanitation and/or animal manure disposition, associated with high salinity waters. In proprieties where the agriculture is the main developed activities, groundwater present low mineralization, but there is a human influence, observed in the increases on nitrate and chloride concentration
253

Substratos artificiais melhoram a qualidade da água em sistema de cultivo multitróficos e multiespaciais?

Andrion, Bruno Cardoso [UNESP] 24 February 2014 (has links) (PDF)
Made available in DSpace on 2014-08-27T14:36:46Z (GMT). No. of bitstreams: 0 Previous issue date: 2014-02-24Bitstream added on 2014-08-27T15:57:18Z : No. of bitstreams: 1 000776866.pdf: 1448728 bytes, checksum: bbd74b45c504a4f80ad12d1a4fd471b7 (MD5) / Na aquicultura a utilização de sistemas de cultivo sem renovação de água, o uso de substratos artificiais com a fixação de perifíton e os sistemas integrados podem ser formas alternativas para aperfeiçoar os atuais sistemas de produção, gerando maior lucro e menor impacto ambiental. O objetivo deste trabalho foi analisar a qualidade da água em sistemas de policultivo com a inserção de substratos artificiais, feitos de bambu e manta geotêxtil, na produção de tilápias (Oreochromis niloticus) e camarões-da-amazônia (Macrobrachium. amazonicum), identificou-se também o substrato com maior crescimento de perifíton. O experimento teve duração de seis meses, sendo composto por 12 viveiros retangulares de fundo natural, povoados com 22 camarões. m-2 e 1,1 tilápias. m-2, com alimento ofertado apenas às tilápias. O delineamento experimental foi inteiramente casualizado, com três tratamentos (controle, bambu e manta) e quatro repetições. Foram analisadas as amostras de água e de perifíton raspados dos substratos. Os resultados apontam que não houve diferença significativa na qualidade da água, provavelmente, devido à alta concentração de sólidos em suspensão que reduz a atividade da comunidade perifítica e devido à baixa biomassa de animais produzidos, não influenciando as concentrações de nitrogênio e fósforo na água. O substrato que proporcionou o maior crescimento da comunidade perifítica foi o tratamento manta geotêxtil / In aquaculture the use of farming systems without water renewal, the use of artificial substrates with fixing periphyton and integrated systems may be alternative ways to improve the current production systems, generating higher profits and lower environmental impact. The aim of this study was to analyze the water quality in polyculture systems with insertion of artificial substrates, made of bamboo and geotextile blanket, in a production of nile tilapias (Oreochromis niloticus) and amazon river prawns (Macrobrachium amazonicum), also identified the substrate with higher growth of periphyton . The experiment lasted six months, being composed of 12 rectangular ponds natural background , populated with 22 prawns.m-2 and 1,1 tilapias.m-2, with food offer only the tilapia . The experimental design was completely randomized with three treatments (control, bamboo and blanket) and four replications. Water samples and periphyton scraped from the substrates were analyzed. The results indicate no significant difference in water quality, probably due to the large amount of suspended solids, which prevented the development of periphyton and due to the low biomass of animals produced, not influencing the concentrations of nitrogen and phosphorus in the water The substrate resulted in the highest growth of periphyton was treating geotextile
254

Derecho al agua y políticas públicas : análisis de la normatividad y políticas públicas sobre el abastecimiento de agua en Brasil y Colombia

Gutierrez Gongora, Catalina Maria 28 February 2018 (has links)
Dissertação (mestrado)—Universidade de Brasília, Faculdade de Direito, Programa de Pós-Graduação em Direito, 2018. / Submitted by Raquel Almeida (raquel.df13@gmail.com) on 2018-05-07T16:07:22Z No. of bitstreams: 1 2017_CatalinaMaríaGutierrezGongora.pdf: 1663014 bytes, checksum: b0198423a3a526b67210f012e09e1ab5 (MD5) / Approved for entry into archive by Raquel Viana (raquelviana@bce.unb.br) on 2018-06-05T20:25:54Z (GMT) No. of bitstreams: 1 2017_CatalinaMaríaGutierrezGongora.pdf: 1663014 bytes, checksum: b0198423a3a526b67210f012e09e1ab5 (MD5) / Made available in DSpace on 2018-06-05T20:25:54Z (GMT). No. of bitstreams: 1 2017_CatalinaMaríaGutierrezGongora.pdf: 1663014 bytes, checksum: b0198423a3a526b67210f012e09e1ab5 (MD5) Previous issue date: 2018-06-05 / Fundação de Apoio à Pesquisa do Distrito Federal (FAP-DF). / O presente trabalho tem como propósito analisar como o direito à água é garantido à população brasileira e colombiana. Identificando, comparando e estudando instrumentos jurídicos internacionais e nacionais entre os dois países, assim como também analisando instrumentos políticos e jurídicos empregados pelos estados para garantir o direito à água. Para cumprir com os objetivos do trabalho, adotou-se uma metodologia de pesquisa do tipo descritiva – qualitativa, usando técnicas de levantamento bibliográfico e situacional, estudando conceitos básicos de Estado Social de direito, administração pública, governança da água, políticas públicas e eficácia, aliado a uma análise estrutural das políticas públicas. No caso Brasileiro, o PLANSAB e no colombiano, o plano de desenvolvimento do setor de água e esgoto e as políticas para fornecimento de água potável e saneamento básico nas áreas rurais. Também foi feita uma coleta e análise de dados secundários obtidos da avaliação do setor água e as políticas públicas de abastecimento de água para a sociedade, isso com a finalidade de quantificar a eficácia da implementação das políticas objeto de estudo. Com a execução desta pesquisa, foi confirmado que o direito à água encontrasse reconhecido internacionalmente como fundamental, apresentando obrigações prestacionais para sua proteção e garantia por parte dos Estados. Mesmo que no Brasil e na Colômbia não se encontre reconhecido o direito à água de forma explicita no ordenamento jurídico interno, o direito deve ser respeitado e protegido, segundo consta nos tratados internacionais acerca de direitos humanos, especificamente o direito à água que tem uma força vinculante em cada país. Da mesma forma, após o estudo comparativo das políticas públicas de abastecimento de água potável selecionadas, encontrou-se que as mesmas respondem adequadamente às diretrizes jurídicas gerais para a proteção do direito à água e foi notado que cada Estado se encontra trabalhando para dar cumprimento aos postulados do Estado Social de direito e as governanças da água que regem cada país. Finalmente tem-se que no que compete à implementação das políticas públicas avaliadas e sua forma de verificação e monitoramento, as políticas colombianas estudadas, a diferença das brasileiras, não possuem uma estrutura forte e responsável, planejada para medir a eficácia do desempenho das mesmas e comprovar se o direito à água encontra-se efetivamente materializado. / The purpose of this paper is to analyze how the right to water is guaranteed by the State to the Brazilian and Colombian population, identifying and studying comparatively between the two countries, the international and national legal instruments that support this right, as well as public policies of access and supply of drinking water existing in these countries, also analyzing how the legal and political instruments of protection and guarantee of the right to water are implemented by the States, for the realization of the right to water. To achieve these objectives, a research methodology of qualitative descriptive type was adopted, using bibliographic and situational survey techniques, studying basic concepts of Social State of Law, public administration, water governance, public policies and efficiency, together with structural analysis of the public policies, in the Brazilian case, the PLANSAB and in the Colombian, the Development Plan of the aqueduct and sewerage sector, and the policy for the supply of drinking water and basic sanitation in the rural area, as well as the collection and analysis of secondary data from the assessment of the water sector and public policies for water supply to society, all in order to measure the effectiveness of the implementation of the policies under study. Finally, it was obtained with the realization of this work, the confirmation that the right to water is internationally recognized as fundamental and involves obligations for the protection and guarantee thereof by States, even if the right to water is not found Recognized explicitly in the domestic legal system of Brazil and Colombia, the right must be respected and protected, because international treaties on human rights and specifically the right to water have binding force in each country. In the same way, after the comparative study of the public policies of drinking water supply selected, they were found to respond adequately to the general legal guidelines for the protection of the right to water, as well as that each State is working on the compliance with the postulates of the Social State of Law, and the governance of water that governs each country. However, faced with the implementation of the public policies examined and their form of verification and monitoring, the Colombian policies analyzed, unlike the Brazilian policies, do not have a strong and responsibly planned structure to measure the effectiveness of their performance and to verify whether the right to water is effectively materialized. / Este trabajo tiene como propósito analizar, como el derecho al agua es garantizado por el Estado a la población brasilera y colombiana, identificando y estudiando comparativamente entre los dos países, los instrumentos jurídicos internacionales y nacionales que respaldan dicho derecho, así como también las políticas públicas de acceso y abastecimiento de agua potable existente en estos países, analizando además, como los instrumentos jurídicos y políticos de protección y garantía del derecho al agua, son implementados por los Estados, para la materialización del derecho al agua. Para cumplir estos objetivos, se adoptó una metodología de investigación de tipo descriptivo cualitativo, utilizando técnicas de levantamiento bibliográfico y situacional, estudiando conceptos básicos de Estado Social de Derecho, administración pública, gobernanza del agua, políticas públicas y eficacia, junto con el análisis estructural de las políticas públicas, en el caso brasilero, el PLANSAB y en el colombiano, el Plan de desarrollo del sector de acueducto y alcantarillado, y la política para el suministro de agua potable y saneamiento básico en la zona rural, así como también la recolección y análisis de datos secundarios arrojados de la evaluación del sector del agua y las políticas públicas de abastecimiento de agua a la sociedad, todo esto con el fin de medir la eficacia de la implementación de las políticas objeto de estudio. Finalmente, se obtuvo con la realización de este trabajo, la confirmación de que el derecho al agua se encuentra reconocido internacionalmente como fundamental y comporta obligaciones prestacionales para la protección y garantía del mismo por parte de los Estados, aunque no se encuentre el derecho al agua reconocido de manera expresa en el ordenamiento jurídico interno de Brasil y Colombia, el derecho debe ser respetado y protegido, en razón a que los tratados internacionales sobre derechos humanos y específicamente el derecho al agua tienen fuerza vinculante en cada país. De la misma manera, luego del estudio comparativo de las políticas públicas de abastecimiento de agua potable seleccionadas, se encontraron que las mismas responden adecuadamente a los lineamientos jurídicos generales para la protección del derecho al agua, así como también que cada Estado está trabajando en el cumplimiento de los postulados del Estado Social de Derecho, y de la gobernanza del agua que rige cada país. Sin embargo, frente a la implementación de las políticas públicas examinadas y su forma de verificación y monitoramiento, las políticas colombianas analizadas a diferencia de la brasilera no comportan una estructura fuerte y responsablemente planeada para medir la eficacia del desempeño de las mismas y comprobar si el derecho al agua esta efectivamente materializado.
255

Determinação de contaminantes emergentes em mananciais de água bruta e na água para consumo humano do Distrito Federal

Santana, Joyce da Silva 15 February 2013 (has links)
Dissertação (mestrado)—Universidade de Brasília, Programa de Pós-Graduação em Química, 2013. / Submitted by Albânia Cézar de Melo (albania@bce.unb.br) on 2013-08-02T12:42:51Z No. of bitstreams: 1 2013_JoyceSilvaSantana.pdf: 2403233 bytes, checksum: 679af1321cbb319789dd86a004254e6b (MD5) / Approved for entry into archive by Guimaraes Jacqueline(jacqueline.guimaraes@bce.unb.br) on 2013-08-02T13:08:57Z (GMT) No. of bitstreams: 1 2013_JoyceSilvaSantana.pdf: 2403233 bytes, checksum: 679af1321cbb319789dd86a004254e6b (MD5) / Made available in DSpace on 2013-08-02T13:08:57Z (GMT). No. of bitstreams: 1 2013_JoyceSilvaSantana.pdf: 2403233 bytes, checksum: 679af1321cbb319789dd86a004254e6b (MD5) / Contaminantes emergentes referem-se às substâncias químicas cujo interesse por estudos associados à ocorrência e efeitos no ambiente é recente. Ainda há uma escassez de dados relacionados à ocorrência destes contaminantes no Brasil, o que motivou a realização do presente trabalho. Foram selecionadas amostras de águas superficiais do Lago Paranoá e de dois mananciais de água do Distrito Federal (DF): Rio Descoberto e Córrego Cabeça de Veado. Também foram analisadas águas para consumo humano, coletadas ao longo do DF. As amostras, coletadas em diferentes épocas do ano, foram investigadas por meio de duas abordagens distintas. A primeira abordagem, baseada no desenvolvimento de um novo método nas dependências da UnB, consistiu na determinação de quatro contaminantes pertencentes a diferentes classes, ou seja, cafeína, atenolol, atrazina e DEET, enquanto que a segunda consistiu em analisar as amostras com vistas à determinação de 16 contaminantes emergentes dentro de um programa de monitoramento encabeçado pelo Instituto Nacional de Ciências e Tecnologias Analíticas Avançadas (INCTAA). A determinação dos analitos foi realizada por cromatografia líquida aclopada à espectrometria de massas em um equipamento do tipo triplo quadrupolo (LC-MS/MS). A análise das amostras pelo método INCTAA, realizada na Universidade Estadual de Campinas (Unicamp), revelou a presença de cinco contaminantes emergentes nas amostras do Lago Paranoá: cafeína, atrazina, bisfenol A, triclosan e fenolftaleína, sendo a primeira a mais frequentemente detectada. Por outro lado, o método desenvolvido e validado na UnB, revelou a presença de todos os contaminantes investigados nas águas do Lago Paranoá. A cafeína foi a substância mais abundante, com concentrações de até 228 ng/L, seguida do atenolol, do DEET e da atrazina. Foram observados níveis mais elevados de concentração durante o período de estiagem para todos os compostos com exceção da atrazina que apresentou um comportamento inverso, indicando possíveis diferenças quanto à origem da contaminação. As amostras em mananciais de água e água para abastecimento urbano apresentaram concentrações sempre muito baixas, não ultrapassando 20 ng/L na maior parte dos casos. ______________________________________________________________________________ ABSTRACT / Emerging contaminants are chemicals whose interest in studies regarding their occurrence or their effects in the environment is still recent. There is little information related to the occurrence of these contaminants in Brazilian waters, which motivated this work. Samples of surface water from Paranoa’s Lake and two water bodies in the Federal District (FD) ― Descoberto river and Cabeça de Veado stream ― were selected. Drinking water samples were also analyzed. Samples were collected at different seasons and were investigated through two distinct approaches. The first one, which was based on the development of a new method at the University of Brasília (UnB), consisted in the determination of four contaminants from different classes, i.e., caffeine, atenolol, atrazine, and DEET. The second one was based on the determination of 16 emerging contaminants according to guidelines established by researchers from the National Institute of Advanced Analytical Science and Technology (INCTAA). The analysis was performed by liquid chromatography coupled to mass spectrometry using a triple quadrupole equipment (LC-MS/MS). Analyzes using the INCTAA method were held at the University of Campinas (Unicamp) revealing the occurrence of five emerging contaminants in samples from Paranoa’s Lake: caffeine, atrazine, bisphenol A, triclosan and phenolphthalein. On the other hand, the method developed and validated at UnB, revealed the presence of all contaminants investigated in Paranoa’s Lake water. Both methods revealed that caffeine was the most frequent contaminant in the samples. Results from method UnB showed that caffeine was also the most abundant analyte, with concentrations up to 228 ng/L, followed by atenolol, DEET and atrazine. When samples from different seasons were compared, higher levels were observed, for all compounds, during the dry season except for atrazine, which showed an opposite behavior, indicating possible differences in the origin of contamination. Samples from raw and drinking water presented the lowest concentrations, not exceeding 20 ng/L in most cases.
256

Tratamento de esgotos sanitários usando reator UASB seguido de microfiltração por membrana submersa / Municipal wastewater treatment using UASB followed by submerged membrane microfiltration

Felizatto, Mauro Roberto 07 March 2017 (has links)
Tese (doutorado)—Universidade de Brasília, Faculdade de Tecnologia, Departamento de Engenharia Civil e Ambiental, Pós-Graduação em Tecnologia Ambiental e Recursos Hídricos, 2017. / Submitted by Raquel Almeida (raquel.df13@gmail.com) on 2017-05-03T21:09:26Z No. of bitstreams: 1 2017_MauroRobertoFelizatto.pdf: 6339725 bytes, checksum: 293e6f2365347e2d41a3decef0d5dcca (MD5) / Approved for entry into archive by Guimaraes Jacqueline (jacqueline.guimaraes@bce.unb.br) on 2017-05-08T10:26:37Z (GMT) No. of bitstreams: 1 2017_MauroRobertoFelizatto.pdf: 6339725 bytes, checksum: 293e6f2365347e2d41a3decef0d5dcca (MD5) / Made available in DSpace on 2017-05-08T10:26:37Z (GMT). No. of bitstreams: 1 2017_MauroRobertoFelizatto.pdf: 6339725 bytes, checksum: 293e6f2365347e2d41a3decef0d5dcca (MD5) / A incorporação da tecnologia de separação por membranas em processos anaeróbios representa uma inovação importante no desenvolvimento da engenharia de tratamento biológico de efluentes de reatores UASB. Esta pesquisa consistiu na avaliação da filtração através de membranas submersas, de microfiltração (0,40 μm), provido de sistema de retrolavagem, durante contínuo tratamento do efluente do reator UASB operando com esgotos sanitários. As membranas utilizadas foram do tipo fibras-ocas e fabricadas com o polímero poli(éter-imida). Durante a operação em modo contínuo por longo período, foi observado o declínio contínuo e acentuado do fluxo do permeado com o decorrer do tempo, com valor final de 5,50 LMH, e que a unidade de microfiltração não respondeu ao método contínuo de controle da incrustação (retrolavagem). O restabelecimento da resistência da membrana limpa (1,8x1012 m-1) só ocorreu com limpeza química efetuada com solução de hipoclorito de sódio. A perda de permeado relativa ao consumo diário no uso na retrolavagem levantado foi de 24% e o consumo específico de energia elétrica do sistema apurado foi de 2,80 kWh/m3. A remoção de matéria orgânica alcançada pela microfiltração de efluente do reator UASB foi de 87% para DBO e 84% para DQO, a remoção global de SST foi de 99% e de 2,02 unidades logarítmicas para Coliformes fecais (CF). Os resultados médios de densidade de CF (~105 NMP/100 mℓ) e sua remoção (2,02 unid. log.) e ausência de ovos de helmintos viáveis no permeado atingiram um nível, nesta pesquisa, que possibilita o reúso de água para irrigação restrita na agricultura altamente mecanizada e para irrigação irrestrita por gotejamento de culturas elevadas, segundo as diretrizes da OMS. / The incorporation of membrane separation technology into anaerobic processes represents an important innovation in the development of biological treatment engineering for UASB reactor effluent. This research evaluated the performance of a submerged membranes filtration, microfiltration membranes (0,40 μm) provided with a backwash system, during continuous treatment of the UASB reactors effluents operating with municipal wastewater. The hollow fiber membranes were manufactured by polyetherimide material. In the long-term operation, the continued and accented decrease of permeate flux over the time was observed, with a final permeate flux approached of 5.50 LMH. The microfiltration unit seems not to answer satisfactorily to strategy in limiting the fouling control (backwash). The restoration of the clean membrane resistance (1.8x1012 m-1) only occurred with chemical cleaning carried out with sodium hypochlorite solution. The permeate loss relative to the daily consumption in the backwash was 24% and the specific energy consumption of the system was 2.80 kWh/m3. The removal of organic matter by the microfiltration of the UASB reactor effluent reached was 87% for BOD and 84% for COD, 99% for TSS removal and 2.02 log. units for fecal coliforms (FC). In this study, the results of the geometric means of FC density (~105 MPN/100 mℓ) and its removal (2.02 log. units) and absence of viable helminthes eggs in the permeate reached a level of water reuse for restricted irrigation in agriculture highly mechanized and for unrestricted drip irrigation of high crops, according to WHO guidelines.
257

Reflectometria no domínio do tempo (TDR) para determinação do conteúdo de água em solos tropicais do Distrito Federal / Time domain reflectometry (TDR) for Brazilian Federal District tropical soils in the water content determination

Costa, Bruna Freire Domingues da 24 February 2017 (has links)
Dissertação (mestrado)—Universidade de Brasília, Programa de Pós-Graduação em Agronomia, Faculdade de Agronomia e Medicina Veterinária, 2017. / Submitted by Albânia Cézar de Melo (albania@bce.unb.br) on 2017-08-18T13:54:58Z No. of bitstreams: 1 2017_BrunaFreireDominguesdaCosta.pdf: 2216388 bytes, checksum: c98cff8cff29b4711004f1ef702512d5 (MD5) / Approved for entry into archive by Raquel Viana (raquelviana@bce.unb.br) on 2017-09-26T18:56:55Z (GMT) No. of bitstreams: 1 2017_BrunaFreireDominguesdaCosta.pdf: 2216388 bytes, checksum: c98cff8cff29b4711004f1ef702512d5 (MD5) / Made available in DSpace on 2017-09-26T18:56:55Z (GMT). No. of bitstreams: 1 2017_BrunaFreireDominguesdaCosta.pdf: 2216388 bytes, checksum: c98cff8cff29b4711004f1ef702512d5 (MD5) Previous issue date: 2017-09-26 / O Brasil é um país privilegiado em relação aos recursos hídricos, porém esses não são distribuídos homogeneamente, pois a maior parte da água se encontra em região com menor densidade populacional. Assim, a racionalização do uso da água e a sustentabilidade dos recursos depende do manejo adequado e uso eficiente da água na agricultura que é a principal usuária desse recurso. O monitoramento do conteúdo de água do solo é de fundamental importância para a agricultura, sobretudo na determinação de sua variação e na otimização do manejo de irrigação. A técnica de Reflectometria no Domínio do Tempo (TDR) é uma importante ferramenta para determinação do conteúdo de água no solo. A propriedade com maior influência sobre a permissividade dielétrica do meio é o conteúdo de água no solo, sendo também influenciada pela mineralogia do solo. Assim, o objetivo deste estudo foi estabelecer equações de calibração entre o conteúdo de água no solo (θ) e a permissividade dielétrica relativa (εr) para Latossolo Vermelho, Latossolo Amarelo, Neossolo, Gleissolo e Organossolo e compará-los com o modelo universal proposto na literatura (Topp et al., 1980), tendo como método padrão de determinação do conteúdo de água no solo, o termogravimétrico. Avaliou-se ainda a possível interferência e efeitos dos óxidos de ferro e de alumínio na calibração do TDR com a determinação da permeabilidade magnética. Foram ajustados modelos polinomiais cúbicos, logarítmicos e de raiz quadrada, para cada classe de solo e para todo o conjunto, entre o conteúdo de água no solo (variável dependente) e a permissividade dielétrica (variável independente). A precisão e a acurácia dos modelos foram avaliadas, pelo coeficiente de determinação (R²), pela raiz quadrada do erro médio (RMSE) e pela a linha 1:1. O modelo proposto por Topp foi o que se mostrou menos adequado para estimar o conteúdo de água das classes de solos estudadas. Os dados do Latossolo Vermelho e do Gleissolo foram melhor ajustados pela equação do modelo logarítmico, com menor RMSE e maior R². Já o Latossolo Amarelo, o Neossolo, o Organossolo e o conjunto de todos os solos foram melhor representados pelo modelo polinomial cúbico, o que o torna o melhor modelo ajustado para esses solos. Considerando apenas os solos minerais, ou seja, excluindo o Organossolo dos modelos, obtém-se uma equação geral ainda melhor em todos os modelos, especificamente, o polinomial cúbico. Os valores de permeabilidade magnética encontrado nos solos foram baixos, o que se justifica uma vez que não foram constatados pela difração de raio-X minerais ferrimagnéticos. Assim, a presença dos óxidos, principalmente a hematita e a goethita, com relação a permeabilidade magnética, não influenciaram os modelos para ajuste de conteúdo de água nos solos estudados. / Brazil is a privileged country regarding water resources. However, these are heterogeneously distributed, since most of the water is located in lower population density areas. Since agriculture is a major user of water, the proper management and efficient use of this resource is dependent of the water rationalization and resources sustainability. Monitoring soil water content is crucial for farming practices, particularly for measuring its variation and optimizing irrigation management. The TDR technique is an important method to determine soil water content, which is the property that have more effect on the dielectric permittivity of the soil (this constant can also be influenced by the soil mineralogy). The aim of this study was to establish calibration equations between soil water content and dielectric permittivity for Aeric Endoaquent, Typic Ustorthent, Typic Haplosaprist, Anionic Acrustox, Rhodic Haplustox and to compare them with the universal model proposed in the literature (Topp et al.,1980), using the standard thermogravimetric model of soil water content measurement as a reference. The possible interference and effects of iron and aluminum oxides in the TDR calibration with determination of magnetic permeability was also investigated. For each soil class and for the whole experimental set, cubic polynomial, logarithmic and square root models were adjusted between soil water content (dependent variable) and dielectric permittivity (independent variable). The precision and the accuracy of the models were assessed using the coefficient of determination (R2), the Root Mean Squared Error (RMSE) and the 1:1 line. The model proposed by Topp et al. was the least adequate to estimate the water content of the soil classes studied. Rhodic Haplustox and Aeric Endoaquent data were better adjusted by the logarithmic model equation, with low RMSE and high R2. The Anionic Acrustox, the Typic Ustorthent, the Typic Haplosaprist and the set of all the soils were better represented by the cubic polynomial model, which makes it the best adjusted model for these soils. Considering only the mineral soils, that is, excluding the Typic Haplosaprist from the models, an overall best fit equation is obtained, in the form of a cubic polynomial. The values of magnetic permeability found in the soils were low, as no ferrimagnetic mineral was detected by X-ray diffraction. Thus, the presence of oxides, mainly hematite and goethite, according to the magnetic permeability were not significant in these models to adjust water content in the studied soils.
258

Estudo de um modelo de otimização dos custos de energia elétrica do bombeamento em sistema de abastecimento de água / Study of model optimization of electric energy cost of pumping in water supply system

Campos, Angélica Luciana Barros de 31 August 2017 (has links)
Dissertação (mestrado)—Universidade de Brasília, Faculdade de Tecnologia, Departamento de Engenharia Civil e Ambiental, 2017. / Submitted by Gabriela Lima (gabrieladaduch@gmail.com) on 2017-12-01T10:33:12Z No. of bitstreams: 1 2017_AngélicaLucianaBarrosdeCampos.pdf: 5730815 bytes, checksum: b494676daf07b29aea95d9f5330d5ed2 (MD5) / Approved for entry into archive by Raquel Viana (raquelviana@bce.unb.br) on 2018-02-08T19:39:36Z (GMT) No. of bitstreams: 1 2017_AngélicaLucianaBarrosdeCampos.pdf: 5730815 bytes, checksum: b494676daf07b29aea95d9f5330d5ed2 (MD5) / Made available in DSpace on 2018-02-08T19:39:36Z (GMT). No. of bitstreams: 1 2017_AngélicaLucianaBarrosdeCampos.pdf: 5730815 bytes, checksum: b494676daf07b29aea95d9f5330d5ed2 (MD5) Previous issue date: 2018-02-08 / Cerca de 90% das despesas com energia elétrica das empresas de saneamento são provenientes de motores elétricos utilizados em estações elevatórias de água. Assim, existe a necessidade de otimizar os custos operacionais do bombeamento em SAAs. Devido à complexidade da operação desses sistemas, a busca da regra operacional otimizada, deve ser feita com o auxílio de rotinas computacionais. No entanto, essa otimização necessita de grande tempo de processamento computacional, tornando-se um impasse na utilização do modelo para a operação real, como no caso do modelo desenvolvido por Gebrim (2013). Assim, o presente trabalho visou desenvolver um modelo de otimização tendo como base o modelo de Gebrim (2013), para definir regras operacionais que minimizem os custos operacionais de energia elétrica provenientes do bombeamento do sistema de abastecimento do Rio Descoberto, localizado no Distrito Federal. As soluções do modelo foram avaliadas a partir da função aptidão que considera além dos custos de energia, o atendimento às restrições operacionais expressas em termos de penalidade. Empregou-se no modelo estratégias como a utilização dos algoritmos de otimização Dynamically Dimensioned Search, Evolução Diferencial e Algoritmo Genético; simplificação do modelo hidráulico; tratamento das penalidades por meio de uma abordagem baseada na lógica fuzzy; e a técnica seeding, com a inserção de uma população inicial conhecida no algoritmo. Os resultados obtidos demonstraram que as estratégias utilizadas foram eficientes para encontrar soluções de menor custo e tempo de processamento se comparados ao modelo de otimização original, no entanto, o número de acionamentos das bombas e válvulas foi excessivo. Além disso, os níveis dos reservatórios gerados apresentaram elevada segurança em sua operação, o que pode encorajar a utilização do modelo pelos operadores do sistema. Portanto, com algumas adaptações como a redução do número de acionamentos e desenvolvimento de um previsor de demanda, o modelo poderá ser utilizado para a operação real. / About 90% of the electricity costs from water companies are from pumps used in water pumping stations. Thus, there is a need to optimize the operating costs of pumping in water supply systems. Due to the complexity of the operation of water supply systems, the search for optimized operating rules must be accomplished with the aid of computational routines. However, this optimization requires a great amount of computational time, becoming an impasse in the use of the model for the real operation. Thus, this study aimed to develop an optimization model, to define operational rules that minimize the operational costs of electricity from the pumping of the Descoberto river water supply system, located in the Federal District – Brazil. Were evaluated the solutions of the model, from the fitness function that considers besides the energy costs, compliance with the operational constraints expressed in terms of penalty. Were used the model strategies such as Genetic Algorithm, Dynamically Dimensioned Search and Differential Evolution optimization algorithms; simplification of the hydraulic model; handling of penalties, through an approach based on fuzzy logic; and the seeding technique, with the insertion of an initial population known in the algorithm. The obtained results demonstrated that the strategies used were efficient to find solutions of lower cost and computational time when compared to the original optimization model, however, leading to excessive pump and valve switches. In addition, the reservoirs levels generated presented high safety in the operation of the reservoirs, which can encourage the use of the model by the system operators. Therefore, with some adaptations as the reduction of the number of pump and valve switches and the development of a demand forecast, the model can be used in the real operation.
259

Reaproveitamento de águas e efluentes inorgânicos de uma indústria petroquímica

Pollo, Liliane Damaris January 2004 (has links)
A escassez de água, o alto custo do tratamento de efluentes e a iminente cobrança pelo uso e descarte da água vêm preocupando a sociedade e incentivando pesquisas na área de otimização do uso da água e minimização de efluentes. O setor industrial é um dos setores que mais tem se preocupado e se empenhado em encontrar soluções para este problema, pois vivencia os dois problemas ao mesmo tempo, a alta demanda de água e o tratamento dos efluentes gerados. É neste contexto que este trabalho se insere, através de um estudo de caso na Companhia Petroquímica do Sul (Copesul), mais especificamente no setor de utilidades. Neste estudo, foi feita uma análise dos principais processos envolvidos, desde a captação da água até seus consumidores finais, para a identificação da demanda de água e dos locais com maior potencial de reaproveitamento. Para tanto, foi necessária a realização de um balanço hídrico da unidade de tratamento de água usando combinações de dados de planta, estimativas e medições em campo, que foram ajustados através de reconciliação de dados. Os resultados obtidos para esta primeira etapa foram satisfatórios, obtendo uma redução do consumo de água estimada em 40 m3.h-1 e economia anual com o tratamento da água e efluentes de aproximadamente R$ 80.000,00. Também foram apresentadas duas propostas de configurações na planta para a aplicação destas alternativas de reaproveitamento. Numa segunda etapa, realizou-se um balanço de massa e energia para a torre de resfriamento, objetivando reduzir tanto o consumo de água de reposição como o descarte de efluente. O potencial de redução obtido na taxa volumétrica de purga do sistema, considerando apenas o efeito evaporativo e estado estacionário, foi estimado em 20 %. As iniciativas de reuso das águas de lavagem e enxágüe dos equipamentos, bem como da otimização do sistema de resfriamento, conduzem a uma redução da demanda de água e da geração de efluentes, trazendo benefícios econômicos e ambientais para a indústria.
260

Qualidade microbiológica, concentração de nitratos em águas de consumo alternativo (minerais e de poços) da cidade de Jaboticabal-SP

Giacometti, Laudicéia [UNESP] 18 December 2001 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:27:23Z (GMT). No. of bitstreams: 0 Previous issue date: 2001-12-18Bitstream added on 2014-06-13T19:35:24Z : No. of bitstreams: 1 giacometti_l_me_jabo.pdf: 1843637 bytes, checksum: 2ee106fa5b043c1aa7396d2737ebf98b (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Fatores como o gosto e o odor associados à população pela desinfecção com cloro realizada em águas de abastecimento público têm estimulado um maior consumo de águas minerais e águas de poços particulares, situação que desperta o interesse pela qualidade desse tipo de abastecimento que tem sido denominado como consumo alternativo. Diante disso, o presente trabalho teve como objetivo verificar a qualidade higiênico-sanitária e a concentração de nitratos em águas engarrafadas e de poços particulares utilizadas pela população de Jaboticabal, SP. Para as águas engarrafadas foram estudadas três marcas, três volumes de embalagens (20 L; 1,5 L; 0,2 L) e 5 lotes. As águas de poços foram analisadas em períodos de seca e chuva. As variáveis analisadas nos dois casos foram: Pseudomonas aeruginosa, clostridios sulfito-redutores, coliformes totais, Escherichia coli, enterococos e teores de nitrato. Os resultados evidenciaram que não existe uniformidade de qualidade das águas condicionadas em galões de 20 L para os diferentes lotes e para as três marcas, o que se deve à deficiência do preparo das embalagens para reutilização. Dentre 225 amostras analisadas, 37% apresentaram-se fora do padrão de potabilidade. Dentre os sete poços acompanhados verificou-se que o poço 6 tem a qualidade microbiológica de sua água influenciada por precipitações pluviométricas. Os poços 5 e 7 apresentaram elevado teor de nitrato. Estes resultados totalizam 2,8% das águas de poço fora dos padrões de potabilidade. / Points like taste and odor associate for population to chlorine disinfection applied in public water supply stimulated a greater utilization of mineral water and from wells, acts that arise the interest about the quality of this kind of supply, which has been designated as alternative means. Consequently, the present work aimed the verification of the hygienic-sanitary quality, and the concentration of nitrates in bottled water and from private wells used by the population of Jaboticabal, SP, Brazil. For bottled water, three brand marks, three size bottles (20 L, 1.5 L, 0.2 L) and 5 batches were analyzed. Waters from wells were analyzed in dry and rainy periods. The varieties analyzed in both cases were: Pseudomonas aeruginosa, sulfide reducers clostridium, whole coliforms, Escherichia coli, enterococcus and nitrate. The results indicated there's no uniformity in the quality of waters bottled in 20 L containers for the different batches and for the three brand marks, due to deficiency in their preparation for reuse. From 225 analyzed samples, 37% presented themselves as out of standard of potability. From the seven wells analyzed there has been verified that the well no. 6 has the microbiological quality of its water influenced by pluvial precipitations. The wells 5 and 7 presented high level of nitrate. These results totalized 2.8% of water from wells out of standard of potability.

Page generated in 0.0546 seconds