• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 198
  • 9
  • 9
  • 9
  • 9
  • 8
  • 2
  • 1
  • 1
  • Tagged with
  • 200
  • 119
  • 68
  • 62
  • 56
  • 47
  • 45
  • 44
  • 39
  • 35
  • 30
  • 29
  • 25
  • 23
  • 22
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
91

Avaliação da resistência à abrasão, microdureza superficial e estabilidade de cor de dentes artificiais de resina acrílica / Evaluation of the abrasion resistance, superficial microhardness and color stability of acrylic resin artificial teeth.

Pâmela Carbone Mello 20 December 2007 (has links)
O objetivo deste trabalho foi avaliar in vitro a resistência a abrasão, a microdureza superficial e a estabilidade de cor de dentes artificiais de resina acrílica. Sete grupos (1- Biolux, 2- Trilux, 3- Blue Dent, 4- Biocler, 5- Orthosit-Vivodent, 6- Postaris-Antaris, 7- Gnathostar-Ivostar), compostos de 12 pre-molares superiores de cada fabricante, sendo 6 contra antagonistas metálicos (Ni-Cr) e 6 contra antagonistas de resina indireta (Solidex), foram delineados em um perfilômetro, antes e após serem submetidos ao ensaio de abrasão. A diferença linear entre a primeira e a segunda leitura foi medida com um paquímetro digital (precisao 0,01mm). Após a análise estatística (análise de variância, teste de Tukey-Kramer, nível de significancia em p<0,05), observou-se que houve diferenças estatísticas significantes entre os grupos e que a marca Postaris apresentou os menores valores de desgaste contra ambos os antagonistas (R=2,33±0,91&micro;m e M=1,78±0,42&micro;m). Para a análise da microdureza superficial Vickers, foram utilizados 6 incisivos laterais superiores de cada marca e 3 leituras (terços incisal, médio e cervical) foram feitas com o auxílio de um microdurômetro. As médias de microdureza superficial Vickers foram submetidas a análise estatística (nível de significancia p<0,05) e com os resultados obtidos concluiu-se que o grupo Biolux (22,1±0,91VHN) seguido do Antaris (21,9±1,58VHN), Ivostar (21,1±0,98VHN) e Biocler (21,0±1,80VHN) apresentaram maiores valores de dureza diferenciando-se do Vivodent (19,1±0,99VHN) e Blue Dent (18,9±1,54VHN), menos duros. Para o ensaio de estabilidade de cor foram utilizados 6 incisivos centrais superiores direitos de cada marca comercial (n=42), submetidos ao processo de envelhecimento artificial acelerado. O aparelho de leitura de cor utilizado foi um Espectrocolorímetro Portátil Modelo Color Guide 45/0 (BYK-Gardner, Alemanha). Cada dente teve sua cor lida antes e imediatamente após o ensaio de envelhecimento artificial. Os valores de &Delta;E foram submetidos a análise estatística com auxílio do programa JMP 5.1 (SAS Institute, EUA) e mostraram que houve diferenças estatisticamente significantes entres os grupos e que apenas a marca Blue Dent (4,37±0,32) apresentou valores de &Delta;E>3,3 considerado, segunda a literatura, clinicamente inaceitável. Para os grupos que tiveram alterações clinicamente aceitáveis, o grupo Antaris/Postaris teve a maior variação de cor (&Delta;E=2,73±0,96) e o grupo Biolux apresentou a menor variação de cor (1,39±0,27). Dentro das limitações da metodologia empregada, concluiu-se que o antagonista utilizado (metal ou resina) influencia a escolha do dente artificial, e que os dentes artificiais testados tem comportamentos diferentes quanto a resistência a abrasão, microdureza superficial e estabilidade de cor. / The objective of this work was to evaluate in vitro the abrasion resistance, the superficial microhardness and the color stability of acrylic resin artificial teeth. Seven groups (1-Biolux, 2 - Trilux, 3 - Blue Dent, 4 - Biocler, 5 - Orthosit-Vivodent, 6 - Postaris-Antaris, 7 - Gnathostar-Ivostar), composed of 12 upper premolar for each manufacturer\'s, being 6 against metallic antagonists (Ni-Cr) and 6 against indirect resin (Solidex) antagonists, were delineated in a perfilometer, before and after the abrasion test. The linear difference between the first and the second readings was measured with a digital calliper (0,01mm precision). After the statistical analysis (variance analysis, Tukey-Kramer\'s test, p<0.05), it was observed that there were significant differences among the groups and that the trademark Postaris presented the smallest wear values against both antagonists (R=2,33±0,91&micro;m and M=1,78±0,42&micro;m). For Vickers superficial microhardness, 6 lateral upper incisors of each mark and 3 readings were used (incisal, medium, and cervical thirds) done with the microdurometer. The averages of Vickers superficial microhardness were submitted to the statistical analysis (p<0.05) and the obtained results show that the group Biolux (22,1±0,91VHN) followed by Antaris (21,9±1,58VHN), Ivostar (21,1±0,98VHN) and Biocler (21,0±1,80VHN) presented higher values, differing from Vivodent (19,1±0,99VHN) and Blue Dent (18,9±1,54VHN), less harders. For the color stability test 6 upper right central incisors of each commercial mark were used (n=42), submitted to the accelerated artificial aging process. The apparel for color reading was a Portable Spectruncolorimeter Model Color Guide 45/0 (BYK-Gardner, Germany). Each tooth had his color read before and immediately after the artificial aging. The &Delta;E values were submitted to the statistical analysis with JMP 5.1 (HEALTHY Institute, USA) software and show that significant differences were found among the groups and that only Blue Dent (4,37±0,32) presented clinically unacceptable values of &Delta;E (&Delta;E>3.3). For the groups that had clinically acceptable color alterations, the Antaris/Postaris group had the largest color variation (&Delta;E=2.73±0.96) and the Biolux group presented to smallest color variation (&Delta;E=1.39±0.27). Within the limitations of the methodology, was concluded that the antagonist (metal or resin) influence the choice of the artificial tooth, and that the tested artificial teeth have different behaviors for the abrasion resistance, superficial microhardness and color stability.
92

Desenvolvimento de eletrodos revestidos para depósitos resistentes ao desgaste abrasivo

Perotti, Ana Paula January 2012 (has links)
O desgaste de máquinas e seus componentes têm grande influência econômica em diversos setores da indústria. Diante dessa situação, tem sido feitos estudos visando desenvolver novos materiais e revestimentos que apresentem maior resistência ao desgaste. O revestimento é um dos métodos mais utilizados quando se procura garantir a uma superfície alguma propriedade mecânica que não é intrínseca ao metal base. O objetivo deste trabalho é realizar um estudo comparativo de ligas de diferentes composições químicas, através do desenvolvimento de um consumível para soldagem manual ao arco elétrico a ser aplicado especialmente para o recobrimento de superfícies submetidas ao desgaste abrasivo. Os eletrodos desenvolvidos foram compostos pela combinação de cromo-carbono e tungstênio-carbono misturados em um revestimento base com rutilo-carbonato de cálcio-fluorita, resultando em eletrodos revestidos com sete diferentes composições. A comparação e avaliação da resistência à abrasão foi feita com base nos dados obtidos no ensaio de desgaste abrasivo, segundo a norma ASTM G65-91, e também baseada nos resultados da composição química, microestrutura e análise microestrutural dos revestimentos. Os resultados mostraram que os depósitos com maior resistência ao desgaste abrasivo foram obtidos com eletrodos com as composições contendo carbono e 7% de tungstênio e carbono e 1,5% de cromo. Esses mesmos depósitos foram os que apresentaram valores mais elevados de microdureza, e em sua microestrutura pode-se perceber a formação de maior quantidade de carbonetos. / The wear in machines and equipments is one of the main sources of economic losses. Nowadays many studies have been conducted to develop new materials and coverages to produce wear resistance. The hardfacing is one of most common methods to produce a deposit having properties not intrinsic to that of the base material. The main objective of this work is to study the viability of using different alloys compositions to produce covered electrodes for shielded metal arc welding (SMAW) resistant to abrasive wear. The covered electrodes were produced adding chromiumcarbon and tungsten-carbon to rutile-calcium carbide-fluorite base. Comparison and evaluation of wear resistance of the developed electrodes was based in ASTM G65-91 wear tests, deposit chemical compositions and the resultant microstructures. The results shown that electrodes containing additions of C-W 7 % and C-Cr 1.5 % produced best performance of wear test deposits. These compositions produced deposits containing the higher amounts of carbides and exhibit higher hardness values.
93

Aplicação de diferentes agentes fluoretados para prevenção de erosão e abrasão do esmalte in vitro / Application of different fluoridated agents for the prevention of enamel erosion and abrasion in vitro

Christiana Murakami Sato 09 August 2013 (has links)
O objetivo deste estudo foi investigar o potencial inibidor de desgaste dentário ocasionado por erosão e abrasão de um novo produto, o verniz ClinPro XT Varnish, em comparação com vernizes fluoretados convencionais à base de TiF4 e NaF. Sessenta amostras de esmalte bovino (n=15/grupo) com microdureza superficial entre 300-380KHN foram selecionadas e aleatoriamente tratadas com: verniz de NaF (Duraphat®, 2,26% F-), verniz de TiF4 (2,45% F-), ClinPro XT varnish (fluoraluminiosilicato e glicerofosfato de cálcio) e controle (sem tratamento). Após receberem os respectivos tratamentos, as amostras foram submetidas a 3 dias de desafios erosivos de 4x5 min/dia (Sprite® Zero) e a abrasão 2x15s/dia, utilizando uma máquina de escovação. Entre os ciclos de erosão e abrasão, as amostras permaneceram em saliva artificial. A perda de esmalte foi medida com perfilômetro óptico. Os dados foram submetidos ao teste Kruskal-Wallis seguido pelo Dunn (p<0,05) .Ambos vernizes de NaF (-5,84m [-12,06; 1,64]b) (mediana ± 95%IC) e TiF4 (-3,60m [-8,72; -0,45]b) foram eficazes em reduzir o desgaste do esmalte quando comparados ao grupo controle (-16,60m [-19,92; -10,04]a). O ClinPro XT varnish permaneceu na superfície do esmalte (106,21m [30,67; 126,22]c), impedindo completamente o desgaste. Assim foi possível concluir que o ClinPro XT teve um efeito superior aos outros vernizes, impedindo completamente a erosão e abrasão do esmalte por 3 dias in vitro. / The purpose of this study was to investigate the erosion and abrasion inhibiting effect of a newly released product, Vanish XT varnish, and compare it to conventional TiF4 and NaF varnishes. Sixty bovine enamel blocks (300-380 KHN) were selected and randomly allocated into 4 treatment groups (n=15/group): NaF varnish (Duraphat®, 2.26% F-), TiF4 varnish (2.45% F-), Vanish XT varnish (fluoroaluminosilicate and calcium glycerophosphate), and control (no treatment). The samples received their respective treatments one single time at the beginning of the experiment. During a total of 3 days, erosive challenges were done 4x5min/day (Sprite Zero®) and abrasion 2x15s/day using a brushing machine. In between the erosive and abrasive challenges and overnight the samples remained immersed in artificial saliva. Enamel loss was measured using a non-contact profilometer. The data were subjected to Kruskal-Wallis and Dunn tests (p<0.05). Both NaF (-5.84m [-12.06; 1.64]b) (median ± 95%CI) and TiF4 (-3.60m [-8.72; -0.45]b) varnishes were able to reduce enamel wear when compared to the control group (-16.60m [-19.92; -10.04]a). Vanish XT varnish remained on the enamel surface (106.21m [30.67; 126.22]c), completely preventing enamel wear. Therefore, we concluded that Vanish XT presented a superior effect when compared to conventional varnishes, completely preventing enamel erosion and abrasion for 3 days in vitro.
94

Estudo da influência das propriedades relacionadas à superfície e à matriz na resistência à abrasão de concretos para pisos / Study on the influence of properties related to the surface and matrix in the abrasion resistance of concrete floors

Silva, Cristina Vitorino da January 2015 (has links)
O desgaste superficial por abrasão é uma manifestação patológica que decorre do atrito entre partículas secas e a superfície do material, causando uma perda progressiva das camadas mais externas da estrutura. Entender esse mecanismo de deterioração e ainda os parâmetros que influenciam a sua ocorrência são preocupações válidas, visto que ele compromete a durabilidade e a funcionalidade de estruturas, tais como pisos de concreto. Além disso, a correção desta manifestação patológica exige gastos elevados com reparo ou substituição do concreto e, dessa maneira, a necessidade de maiores estudos buscando ações mais efetivas na prática é justificada. Neste particular, estudou-se a influência das propriedades relacionadas à matriz e à superfície na resistência à abrasão dos compósitos. Para tanto, alguns fatores que influenciam na qualidade dos concretos empregados em pisos, como o tipo de cimento (CP IV; CP V-ARI), a relação água/aglomerante (0,40; 0,60), o teor de substituição de sílica ativa (0%; 10%) e o tipo de cura (submersa; caixa aquecida) foram avaliados. Os ensaios adotados para estudar a influência das propriedades de massa no mecanismo de degaste foram os de resistência à compressão uniaxial, resistência à tração na flexão e exsudação. Já os ensaios para verificar a influência das propriedades de superfície na magnitude desse mecanismo foram os de dureza superficial, resistência à abrasão, porosimetria por intrusão de mercúrio, microdureza por indentação, análises em microscópio estereoscópico e a digitalização tridimensional à laser. Os resultados encontrados mostraram uma influência estatística significativa do tipo de cimento sobre todas as propriedades avaliadas, sendo que o cimento de alta resistência inicial apresentou melhor desempenho em comparação ao cimento pozolânico, considerando uma mesma idade de análise (63 dias). Além disso, verificou-se uma influência estatística significativa da relação a/agl no comportamento dos concretos, onde a relação a/agl 0,6 aumentou os índices de desgaste das amostras em relação as de referência (a/agl 0,4), conforme esperado. Quanto ao tipo de cura, os compósitos curados de forma submersa apresentaram os melhores resultados frente ao desgaste superficial comparando-se àqueles mantidos na cura em caixa aquecida. Finalmente, analisando o teor de substituição de sílica ativa, observou-se que a substituição de 10 % sobre a massa de cimento proporcionou acréscimos estatisticamente significativos na resistência à abrasão das amostras com menor relação a/agl; somando-se a isto, a presença da sílica minimizou o efeito da cura em caixa aquecida na camada superficial das amostras de concreto submetidas ao desgaste. Concluindo, a resistência à abrasão dos concretos mostrou ter uma importante relação não somente com as suas propriedades de massa, mas também com a qualidade da sua camada superficial, uma vez que apresentou forte correlação com as características de superfície avaliadas, como a dureza superficial, a microdureza e a porosimetria ao mercúrio. Além disso, salienta-se que o ensaio de dureza superficial por esclerometria poderia ser adotado como parâmetro para determinação direta da resistência ao desgaste e sugere-se que a exsudação dos pisos de concreto venha a ser o fator principal no controle da qualidade da camada superficial da placa de concreto. / Surface abrasion wear is a pathological manifestation triggered by friction between dried particles and the surface of the material, provoking a progressive loss of the outermost layers. The comprehension of this mechanism of deterioration and also the parameters that influence its occurrence are valid concerns, since it compromises the durability and functionality of structures such as concrete floors. In addition, repair this pathological manifestation or replace the damage concrete require high expenditure. Thus, the necessity of further studies seeking for practical effective actions is justified. In this particular, the aim of this work was to study the influence of properties related to the matrix and the surface of composites on abrasion resistance. For this purpose, some factors that influence the quality of the concrete used in floors, including the cement type (CP IV; CP V-ARI), the water / binder ratio (0.40, 0.60), the replacement content of silica fume (0%, 10%) and the conditions of cure (submerged; heat box) were evaluated. The assays employed in order to study the influence of mass properties on the wear mechanism were the compressive strength, flexural tensile strength and bleeding. As regards to the influence of surface properties on the magnitude of this mechanism, it was verified by testing the surface hardness, abrasion resistance, porosimetry by mercury intrusion, microhardness by indentation, analysis in stereoscopic microscope and three-dimensional laser scanning. The obtained data demonstrated a statistically significant influence of cement type on all assessed properties, with the high early strength cement presenting a better performance as compared to pozzolan cement, considering a similar age of analysis (63 days). Furthermore, there was a statistically significant influence of water / binder ratio on concrete behavior, where the water / binder ratio of 0.6 increased the wear rates of the samples in comparison to the reference (water / binder 0.4), as expected. Regarding to the conditions of cure, the submerged composites showed better results against surface wear as compared to those kept in the heat box. Finally, it was observed that the replacement content of silica fume of 10% on the cement mass provided statistically significant increases in abrasion resistance of samples with lower water / binder ratio. In addition, the presence of silica minimized the effects of curing in a heat box on the surface layer of concrete samples that were submitted to wear. In conclusion, the abrasion resistance of concretes demonstrated an important relationship not only with the mass properties of these structures but also with the quality of their surface layer, since a strong correlation with the evaluated surface features was observed, including surface hardness, microhardness and porosimetry by mercury intrusion. Moreover, it is emphasized that the surface hardness assay by rebound hammer may be used as a parameter for direct determination of wear resistance and it is suggested that bleeding of concrete floors might be the main factor for controlling the surface layer quality of the concrete slab.
95

Avaliação da resistência à abrasão, microdureza superficial e estabilidade de cor de dentes artificiais de resina acrílica / Evaluation of the abrasion resistance, superficial microhardness and color stability of acrylic resin artificial teeth.

Mello, Pâmela Carbone 20 December 2007 (has links)
O objetivo deste trabalho foi avaliar in vitro a resistência a abrasão, a microdureza superficial e a estabilidade de cor de dentes artificiais de resina acrílica. Sete grupos (1- Biolux, 2- Trilux, 3- Blue Dent, 4- Biocler, 5- Orthosit-Vivodent, 6- Postaris-Antaris, 7- Gnathostar-Ivostar), compostos de 12 pre-molares superiores de cada fabricante, sendo 6 contra antagonistas metálicos (Ni-Cr) e 6 contra antagonistas de resina indireta (Solidex), foram delineados em um perfilômetro, antes e após serem submetidos ao ensaio de abrasão. A diferença linear entre a primeira e a segunda leitura foi medida com um paquímetro digital (precisao 0,01mm). Após a análise estatística (análise de variância, teste de Tukey-Kramer, nível de significancia em p<0,05), observou-se que houve diferenças estatísticas significantes entre os grupos e que a marca Postaris apresentou os menores valores de desgaste contra ambos os antagonistas (R=2,33±0,91&micro;m e M=1,78±0,42&micro;m). Para a análise da microdureza superficial Vickers, foram utilizados 6 incisivos laterais superiores de cada marca e 3 leituras (terços incisal, médio e cervical) foram feitas com o auxílio de um microdurômetro. As médias de microdureza superficial Vickers foram submetidas a análise estatística (nível de significancia p<0,05) e com os resultados obtidos concluiu-se que o grupo Biolux (22,1±0,91VHN) seguido do Antaris (21,9±1,58VHN), Ivostar (21,1±0,98VHN) e Biocler (21,0±1,80VHN) apresentaram maiores valores de dureza diferenciando-se do Vivodent (19,1±0,99VHN) e Blue Dent (18,9±1,54VHN), menos duros. Para o ensaio de estabilidade de cor foram utilizados 6 incisivos centrais superiores direitos de cada marca comercial (n=42), submetidos ao processo de envelhecimento artificial acelerado. O aparelho de leitura de cor utilizado foi um Espectrocolorímetro Portátil Modelo Color Guide 45/0 (BYK-Gardner, Alemanha). Cada dente teve sua cor lida antes e imediatamente após o ensaio de envelhecimento artificial. Os valores de &Delta;E foram submetidos a análise estatística com auxílio do programa JMP 5.1 (SAS Institute, EUA) e mostraram que houve diferenças estatisticamente significantes entres os grupos e que apenas a marca Blue Dent (4,37±0,32) apresentou valores de &Delta;E>3,3 considerado, segunda a literatura, clinicamente inaceitável. Para os grupos que tiveram alterações clinicamente aceitáveis, o grupo Antaris/Postaris teve a maior variação de cor (&Delta;E=2,73±0,96) e o grupo Biolux apresentou a menor variação de cor (1,39±0,27). Dentro das limitações da metodologia empregada, concluiu-se que o antagonista utilizado (metal ou resina) influencia a escolha do dente artificial, e que os dentes artificiais testados tem comportamentos diferentes quanto a resistência a abrasão, microdureza superficial e estabilidade de cor. / The objective of this work was to evaluate in vitro the abrasion resistance, the superficial microhardness and the color stability of acrylic resin artificial teeth. Seven groups (1-Biolux, 2 - Trilux, 3 - Blue Dent, 4 - Biocler, 5 - Orthosit-Vivodent, 6 - Postaris-Antaris, 7 - Gnathostar-Ivostar), composed of 12 upper premolar for each manufacturer\'s, being 6 against metallic antagonists (Ni-Cr) and 6 against indirect resin (Solidex) antagonists, were delineated in a perfilometer, before and after the abrasion test. The linear difference between the first and the second readings was measured with a digital calliper (0,01mm precision). After the statistical analysis (variance analysis, Tukey-Kramer\'s test, p<0.05), it was observed that there were significant differences among the groups and that the trademark Postaris presented the smallest wear values against both antagonists (R=2,33±0,91&micro;m and M=1,78±0,42&micro;m). For Vickers superficial microhardness, 6 lateral upper incisors of each mark and 3 readings were used (incisal, medium, and cervical thirds) done with the microdurometer. The averages of Vickers superficial microhardness were submitted to the statistical analysis (p<0.05) and the obtained results show that the group Biolux (22,1±0,91VHN) followed by Antaris (21,9±1,58VHN), Ivostar (21,1±0,98VHN) and Biocler (21,0±1,80VHN) presented higher values, differing from Vivodent (19,1±0,99VHN) and Blue Dent (18,9±1,54VHN), less harders. For the color stability test 6 upper right central incisors of each commercial mark were used (n=42), submitted to the accelerated artificial aging process. The apparel for color reading was a Portable Spectruncolorimeter Model Color Guide 45/0 (BYK-Gardner, Germany). Each tooth had his color read before and immediately after the artificial aging. The &Delta;E values were submitted to the statistical analysis with JMP 5.1 (HEALTHY Institute, USA) software and show that significant differences were found among the groups and that only Blue Dent (4,37±0,32) presented clinically unacceptable values of &Delta;E (&Delta;E>3.3). For the groups that had clinically acceptable color alterations, the Antaris/Postaris group had the largest color variation (&Delta;E=2.73±0.96) and the Biolux group presented to smallest color variation (&Delta;E=1.39±0.27). Within the limitations of the methodology, was concluded that the antagonist (metal or resin) influence the choice of the artificial tooth, and that the tested artificial teeth have different behaviors for the abrasion resistance, superficial microhardness and color stability.
96

Avaliação comparativa de resinas compostas fluidas em relação a resistência à abrasão (escovação simulada). / Abrasion resistance of flowable resin composites by comparative analysis of simulated toothbrushing.

Garcia, Fernanda Cristina Pimentel 02 March 2001 (has links)
O presente estudo procurou analisar, através de um teste de abrasão in vitro por escovação simulada, a perda de massa e a alteração da rugosidade superficial em resinas compostas "fluidas" e resinas compostas controles. As marcas comerciais utilizadas foram: Aeliteflo-Bisco (A), Natural Flow-DFL (N), Wave-SDI (W), Flow-It Lf-Jeneric/Pentron (FLf) e Flow-It-Jeneric/Pentron (F). Uma resina composta de partículas híbridas Z100-3M (Z) e uma de micropartículas Silux Plus-3M (S) foram utilizadas como controle. Foram confeccionados 84 corpos-de-prova, de 5mm de diâmetro e 3mm de espessura, sendo 12 para cada marca comercial utilizada. Para o acabamento e o polimento dos corpos-de-prova foram utilizados discos Sof-Lex (3M) nas granulações fina (cor azul média) e superfina (cor azul claro), por tempo médio de 15/20 segundos, para cada granulação, em baixa velocidade. Para os ensaios de abrasão, foi utilizada uma máquina apropriada associada à escova Colgate Classic Infantil (Colgate-Palmolive) de cerdas macias e solução do creme dental, Colgate Proteção Anticáries com MFP (Colgate-Palmolive), diluído em água deionizada na proporção de 1:2. No teste in vitro, foram realizados aproximadamente100.000 ciclos. A determinação do desgaste dos materiais foi verificada pela quantidade de massa perdida após os ensaios, com a utilização de uma balança analítica Sartorius. A rugosidade foi determinada quantitativamente na superfície dos corpos-de-prova, com o auxílio de um rugosímetro Hommel Tester T 1000, comparando a diferença obtida após os testes de escovação e, qualitativamente, por microscopia eletrônica de varredura. Os resultados foram analisados pela variância a um critério ANOVA e pelo Teste de Tukey com p<0,05. Pelo coeficiente de Pearson não foi verificada correlação (r=-0,0296) entre porcentagem de perda de massa e rugosidade de superfície. Os materiais não apresentaram diferenças estatisticamente significantes quanto à alteração de massa, somente quanto à rugosidade superficial. A resina A apresentou a maior alteração de massa, (3,77%), seguida da resina de micropartículas S (3,04%). Em contrapartida, a resina híbrida convencional Z apresentou a menor alteração de massa (1,29%), ficando o restante das resinas "fluidas" com alteração intermediária a estas três resinas. A maior alteração de rugosidade foi verificada para a resina W (1,1720mm), com diferenças estatisticamente significantes em relação às outras resinas testadas: S (0,2749mm), Z (0,2495mm), FLf (0,1597mm), F (0,1217mm), N (0,0620mm) e A (0,0505mm). / This research aimed to assess the wear of flowable resin composites through an in vitro simulated toothbrushing abrasion test. The weight loss and surface roughness analysis were performed using five commercial brands: Aeliteflo, Flow-It, Flow-It Lf, Natural Flow and Wave. Hybrid Z-100 and Microfilled Silux Plus composites have been included as controls. Twelve samples (discs) of each material were prepared with 5mm thickness and 3mm in diameter. The test was performed up to 100.000 cicles with an appropriate machine containing soft bristles tips, dentifrice solution and deionized water in order to simulate toothbrushing. The weight loss was determined by the differences between the initial and final weights ( before and after toothbrushing) using a Sartorius analytical scale. After 5 readings, in a T 1000 Hommel testing machine, the evaluation of surface roughness was obtained by the differences between initial and final means. The analyzed ( ANOVA and Tukey, p< 0,05) results showed that Silux Plus, Flow-it, Wave, Flow-It Lf and Natural Flow had an intermediate weight loss (3,04; 2,70; 2,19; 2,12 and 2,04% respectively). Z-100 exhibited the lowest (1,29%) weight loss, whereas Aeliteflo, the highest (3,77%). Wave showed the highest surface roughness variation (1,1720mm), statistically different from the other groups, which exhibited the following differences: Silux Plus (0,2749mm), Z-100 (0,2495mm), Flow-it Lf (0,1597mm), Flow-It (0,1217mm), Natural Flow (0,0620mm) and Aeliteflo (0,0506mm). Aeliteflo presented the highest weight loss and the lowest surface roughness difference; on the other hand, Wave showed the highest surface roughness difference and an intermediate weight loss when compared with the other tested resins.
97

Impacto de um dentifrício contendo silicato de cálcio, fosfato e flúor no desgaste erosivo da dentina / Impact of a dentifrice containing calcium silicate, phosphate, and fluoride on erosive dentin wear

Silva, Juliana Calistro da 29 August 2017 (has links)
O presente estudo teve como objetivo avaliar in situ a eficácia da aplicação do dentifrício com adição de silicato de cálcio, fosfato e flúor na prevenção do desgaste erosivo, considerando os episódios de erosão e/ou abrasão da dentina. Utilizando um protocolo in situ, após a confecção dos blocos de dentina de dentes bovinos, foi realizada a dureza de superfície para seleção dos espécimes e a análise do perfil inicial. Por conseguinte, os espécimes foram distribuídos em dispositivos intrabucais utilizados pelos voluntários previamente selecionados, após o cálculo da amostra. Os grupos em estudo foram GI e GII aplicação de dentifrício com adição de silicato de cálcio, fosfato e flúor (REGENERATE Enamel Science), pH 9,60; controles positivos GIII e GIV - aplicação de dentifrício AmF-NaF-SnCl2 (Elmex® EROSION PROTECTION), pH 4,54; e controles negativos GV e GVI - aplicação de água; sendo que os grupos pares foram submetidos a erosão (ERO) e os ímpares a erosão mais abrasão (ERO+ABR). O estudo foi randomizado, cruzado e cego para o pesquisador, contendo três fases, de acordo com cada tratamento experimental, controle positivo e controle negativo. Em cada uma das fases in situ de cinco dias, 16 voluntários utilizaram dispositivos palatinos (quatro blocos: dois ERO e dois ERO+ABR), os quais 4x/dia eram imersos em ácido cítrico 0,5% por 2 minutos e 2x/dia o voluntário aplicava solução de dentifrício, concentração 1:3 (slurry) ou água, de acordo com cada tratamento, nos quatro espécimes após a primeira e terceira ciclagem. Em dois deles, a escovação era realizada com escova elétrica por 15 segundos por espécime, para simular episódios de abrasão, após a aplicação do slurry. A variável de resposta adotada foi a perfilometria. Os dados foram analisados por ANOVA a dois critérios e teste de Tukey (p<0,05). A perda de dentina foi semelhante para erosão e erosão associada à abrasão. O tratamento com dentifrício Elmex foi capaz de prevenir a perda em dentina de 23% para erosão e 26% para erosão associada à abrasão, sendo a perda de dentina estatisticamente menor, que o dentifrício Regenerate e o controle água, sendo que os dois últimos resultaram em desgaste estatisticamente semelhante. Conclui-se que o uso do dentifrício contendo silicato de cálcio, fosfato de sódio e flúor não foi capaz de diminuir a perda de dentina frente a desafios erosivos e abrasivos. / This study aimed to evaluate the effectiveness of in situ application of a dentifrice containing calcium silicate, phosphate, and fluoride on the prevention of erosive wear, considering the episodes of dentin erosion and/or abrasion. This was an in situ study. After the construction of the dentin blocks from bovine teeth, the surface hardness was performed to select the specimens followed by the initial profile analysis. Then, the specimens were placed in intraoral devices used by previously selected volunteers, after the sample size calculation. The study groups were: GI and GII application of dentifrice containing calcium silicate, phosphate, and fluoride (REGENERATE Enamel Science ) pH 9,60; positive controls GIII and GIV - application of AmF-NaF-SnCl2 dentifrice (Elmex® EROSION PROTECTION) pH 4,54; and negative controls GV and GVI - application of water. The even-numbered groups were subjected to erosion (ERO) and the odd-numbered groups to erosion and abrasion (ERO + ABR). This randomized, cross, and blinded study had three stages (one per type of treatment). In each of the 5-day in situ stages, 16 volunteers worn the palatal devices (4 blocks: 2 ERO and 2 ERO + APR), which were immersed into 0.5% citric acid, for 2 min, 4x/day. The volunteer applied either the dentifrice slurry (1:3 concentration) or water on the four specimens, 2x/day after the first and third cycling. On two specimens, toothbrushing was performed with electric toothbrush for 15 s per specimen, to simulate episodes of abrasion, after slurry application. The response variable adopted was the profilometry. Data were analyzed by two-way ANOVA and Tukey test (p<0.05). The dentin loss was similar both for erosion and erosion associated to abrasion. Treatment with Elmex dentifrice promoted a dentin loss of 23% for erosion and 26% for erosion associated with abrasion, with statistically smaller than that of the dentifrice Regenerate and the water control. The water control had a wear statistically similar to the dentifrice Regenerate. In conclusion, the use of a dentifrice containing calcium silicate, sodium phosphate, and fluoride was not able to decrease the dentin loss after erosive and abrasive challenges.
98

Desenvolvimento de um ferro fundido branco fortemente ligado ao Vanádio e ao Manganês resistente ao desgaste e ao choque

Azevedo, Luís André Xavier Pinto de January 2010 (has links)
Tese de mestrado integrado. Engenharia Engenharia Metalúrgica e de Materiais. Faculdade de Engenharia. Universidade do Porto. 2010
99

Estudo epidemiológico de lesões não cariosas em tecidos dentários / Epidemiological report in non-carious lesions in dental tissues

Ibarra, Eliana Guadalupe Balseca 23 November 2018 (has links)
O desgaste dental é uma patologia presente na população, sendo estudada principalmente em populações infantis, determinar a prevalência de desgaste dentário em uma população jovem e como isso afeta a qualidade de vida nos permite estabelecer o diagnóstico oportuno e seu respectivo tratamento. As lesões não cariosas representam uma perda irreversível de tecido dentário que inclui patologias posteriores que afetam a qualidade de vida dos pacientes. O objetivo deste estudo foi determinar a prevalência de lesões não cariosas, assim como relacionar com o de desgaste, o gênero e a idade, determinando também o possível impacto do desgaste dentário na qualidade de vida das pessoas. A população do estudo incluiu 400 estudantes das Faculdades de Odontologia e de Ciências Psicológicas da Universidade Central do Equador, com idades de 19 a 27 anos. As lesões não cariosas foram identificadas de acordo com o índice de Desgaste Dentário IDD, e foi aplicado o questionário de Qualidade de Vida OHIP14. Os dados obtidos da observação clínica, assim como da aplicação da entrevista, foram armazenados e codificados em uma planilha Microsoft Excel 2010, a partir da qual foram feitos os cálculos da frequência dos níveis de impacto e pontuações médias para as dimensões do questionário de qualidade de vida. Para determinar o grau de correlação entre as duas variáveis principais do estudo utilizou-se o Coeficiente de Person. A prevalência de lesões não cariosas na cavidade oral foi de 3,3%, determinando que o setor correspondente aos incisivos anteriores inferiores apresentou 34,3% na região do esmalte, enquanto no setor correspondente aos incisivos anteriores superiores observou-se 2,9% de envolvimento na região dentinária, o desgaste das bordas incisais nos caninos superiores ocorreu em 7,3%, afetando a dentina. Não foram encontradas diferenças significativas, em relação ao gênero (p>0,05, de acordo com U de Mann Whitney), nem com relação à idade (p>0,05, de acordo com Kruskal Wallis). No que diz respeito à qualidade de vida, a dimensão dor apresentou um nível médio de 1,31, seguida por dificuldade psicológica com média de 1,29. As dimensões restantes apresentaram valores inferiores a 1. Portanto, conclui-se que a prevalência de desgaste dentário ocorreu em 3,3% no esmalte e 0,5% na dentina em toda a boca. A região incisal dos incisivos centrais inferiores apresentou um desgaste significativo em relação às superfícies dentárias dos outros dentes. A dor e a dificuldade psicológica foram os aspectos mais afetados em relação à qualidade de vida. Não foram encontradas diferenças significativas entre gênero e idade em relação à prevalência de desgaste dentário e impacto na qualidade de vida. / The dental wear is a pathology that is present in the population, being mainly studied in children populations principally, to determinate the prevalence of dental wear in a young population and how it affects the quality of life, allows us to establish the appropriate diagnosis and its respective treatment. Non-carious lesions represent irreversible loss of dental tissue that includes later pathologies affecting the patients\' quality of life. The aim of this report is to determine the prevalence of non-carious lesions, as well as to relate to the level of attrition, gender and age, also determining the possible impact on the quality of life of the subjects of study. The study population was 400 students from the Faculties of Dentistry and Psychological Sciences of the Central University of Ecuador, aged from 19 to 27 years. Those patients with presence of non-carious lesions were identified according to the Index of Dental Wear. IDW, in them the OHIP14 quality of life questionnaire was applied. The data obtained from the clinical observation as well as from the application of the survey were stored and codified in a Microsoft Excel 2010 sheet, from which were made frequency calculations of impact levels and average scores for the dimensions of the quality of life questionnaire. To determine the degree of correlation between the two main study variables, the Person Coefficient was applied. The prevalence of non-carious lesions at the general level in the oral cavity was 3.3%, determining that the sector corresponding to the lower anterior incisors presented 34.3% in the enamel region, whereas in the sector corresponding to the anterior superior incisors, 2.9% involvement was observed in the dentin region, the wear of the incisal edges in the maxillary canines occurred in 7,3%, affecting dentin. No significant differences were found in the sex dimensions (p> 0.05, according to U Mann Whitney), nor in relation to age (p> 0.05, according to Kruskal Wallis). Regarding Quality of life, the pain dimension presented a mean level of 1.31 followed by psychological difficulty - with average of 1.29. The remaining dimensions presented values lower than 1. Therefore conclued that, the prevalence of tooth wear occurs at 3.3% at the enamel level and at 0.5% at the dentin level throughout the mouth. The incisal surface of the lower central incisors showed significant wear in relation to the surfaces of other teeth. Pain and psychological difficulty were the aspects most affected in relation to quality of life. No significant differences were found between gender and age in relation to the prevalence of tooth wear and impact on quality of life.
100

Efeito da escovação na resistência à corrosão do titânio cp / The effect ofd brushingand corrosion on cp titanium

Gustavo da Col dos Santos Pinto 29 April 2014 (has links)
O uso de ligas metálicas na odontologia continua tendo aplicação em grande número de situações clínicas de próteses convencionais ou sobre implantes. O objetivo deste estudo foi avaliar a corrosão superficial do Ti cp, submetido a processo de escovação. Foram confeccionados espécimes, com 15,0 mm de diâmetro e 2,5 mm de espessura, obtidos pelo método de fundição por cera perdida. Em seguida, divididos em 4 grupos (n=6). Ensaios eletroquímicos e escovação mecânica (abrasão) foram realizados. Para a análise de Potencial em Circuito Aberto (OCP), o período de mensuração foi de 1 hora, com leitura do potencial da amostra a cada 0,6 segundos. No Grupo G1 foi realizada a análise de Pontecial em Circuito Aberto (OCP), em seguida, aplicado um Potencial Anódico a -250 mV por 1 hora e logo após, realizada a Espectroscopia de Impedância Eletroquímica (EIS) à -250mV. Para o Grupo G2 foi realizada a análise de OCP, em seguida, aplicado um Potencial Catódico a +1000 mV por 1 hora e logo após, realizada a EIS à +1000 mV. Os Grupos G1 e G2 não foram submetidos ao teste de escovação mecânica. O Grupo G3 foi submetido, primeiramente, ao ensaio de escovação mecânica, sendo a máquina acionada até atingir 14.600 ciclos, que representa 1 ano de escovação por um indivíduo saudável52 e corresponde a 41 minutos de funcionamento do equipamento. Posteriormente, foi realizada a mesma sequência do ensaio corrosivo do Grupo G1, ou seja: OCP + Aplicação de Potencial anódico à -250mV + EIS à -250 mV. Para o Grupo G4 primeiro foi realizado o ensaio de escovação mecânica, (14.600 ciclos). Em seguida, foi realizado a mesma sequência do ensaio corrosivo do Grupo G2 , ou seja: OCP + Aplicação de Potencial Catódico à +1000 mV + EIS a +1000 mV. Os resultados obtidos mostram não haver alteração estatisticamente significante na rugosidade superficial dos corpos-de-prova entre os grupos testados. No entanto, as imagens obtidas através dos testes de Interferometria Digital 3D e Microscopia eletrônica de varredura, sugerem a formação de superfícies com menos irregularidades, para os grupos 3 e 4, os quais foram submetidos a escovação mecânica antes dos ensaios eletroquímicos. Os valores da resistência do óxido (Róxido) observada após a EIS á -250 mV (grupos 1 e 3) e á + 1000 mV (grupos 2 e 4) foram estaticamente diferentes entre si (p&le;0,05), sendo que os grupos 1 e 2 , submetidos somente ao teste eletroquímico, demonstraram menor resistência do óxido, quando comparados com os grupos 3 e 4, escovados mecanicamente antes do teste eletroquímico. Concluiu-se que a escovação interfere positivamente na resistência a corrosão do Ti cp. / The use of metal alloys in dentistry continues to have application in many clinical situations of conventional prosthesis and implants. The aim of this study was to evaluate the effect of brushing and corrosion on the cp Ti surface. Specimens were prepared with 15.0 mm diameter and 2.5 mm thickness, obtained by the method of lost wax casting. Then divided into 4 groups (n=6). Electrochemical tests and mechanical brushing (abrasion) were performed. For the analysis of Open Circuit Potential (OCP), the measurement period was 1 hour, with the potential of sample reading every 0.6 seconds. For Group G1 Pontecial Open Circuit (OCP) analysis was performed, then applying a Anode potential at -250 mV for 1 hour and soon after, performed the Electrochemical Impedance Spectroscopy (EIS) at -250mV. For the Group G2 OCP analysis was performed, then applying a Cathodic Potential at +1000 mV for 1 hour and soon after, performed the EIS at +1000 mV. The Groups G1 and G2 were not subjected to mechanical brushing test. The Group G3was submitted, first, the mechanical brushing, and the machine was thrown up to 14,600 cycles, which represents 1 year of brushing for a healthy individual [52] and corresponds to 41 minutes of operation of the equipment. Subsequently, the same sequence of G1 Group corrosive test was performed (OCP + Potential Application of anodic at - 250mV + EIS at -250 mV). For the group G4, first mechanical brushing (14,600 cycles) was performed. Then was performed the same sequence of Group G2 corrosive test, (OCP + Application of Cathodic Potential at +1000 mV + EIS at +1000 mV). The results showed no statistical significance change of surface roughness between the tested groups. However, the images obtained through the 3D Digital interferometry and scanning electron microscopy tests , suggest the formation of surfaces with less irregularities, for groups 3 and 4, which were subjected to mechanical brushing before the electrochemical tests. The oxide resistance values (Róxido) observed after the EIS at -250 mV (groups 1 and 3) and at +1000 mV (groups 2 and 4) were statistically different ( p &le; 0.05 ), and the groups 1 and 2 ,subjected only to the electrochemical test showed less oxide resistance when compared with groups 3 and 4, mechanically brushed before the electrochemical testing. It was concluded that brushing positively interferes at the corrosion resistance of cp Ti.

Page generated in 0.0218 seconds