• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 136
  • 49
  • 22
  • 20
  • 18
  • 6
  • 6
  • 5
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • Tagged with
  • 293
  • 119
  • 58
  • 58
  • 56
  • 54
  • 41
  • 40
  • 37
  • 32
  • 30
  • 27
  • 26
  • 25
  • 24
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
211

Comparação in vitro do desgaste dental em função da dureza de três diferentes tipos de materiais antagonistas / In vitro comparison of dental wear according to the hardness of three different antagonist materials

Ana Paula Cunha da Silva Costa 08 October 2010 (has links)
O objetivo deste estudo foi comparar in vitro o desgaste dental de pré-molares (PM) e molares (M) e sua relação com o valor de dureza Vickers dos materiais utilizados como antagonistas em uma máquina de abrasão simulada para provocar o desgaste nos dentes testados. Os materiais antagonistas utilizados foram VeraBond II (liga de Ni-Cr), Solidex (resina composta) e IPS Empress 2 (cerâmica). Para cada ensaio de dureza, foram preparados seis corpos-de-prova de cada material, os quais foram polidos sob refrigeração, com ciclo de 20 min para cada granulação. Num microdurômetro (HMV-2), foram realizadas três mossas por quadrante, cada uma sob carga de 19,614 N por 30 s, totalizando 12 mossas de base quadrada com ângulo de 136 entre os planos. O teste de abrasão foi realizado numa máquina simuladora de abrasão, freqüência de 265 ciclos/min e 4,4 Hz, com um percurso do antagonista de 10 mm à velocidade de 88 mm/s. Cada dente foi testado em oposição a um antagonista (foram 6 pares dente/material para cada grupo), em água deionizada, sob carga de 5 N, por 150 min, num total de 39.750 ciclos. Foram utilizados dezenove dentes 1 pré-molares, dezenove 3 molares e confeccionados doze antagonistas em cada material em forma de pastilha. Cada grupo de seis dentes foi testado em oposição a seis antagonistas do mesmo material. Ademais, um dente 1 pré-molar (PM) e um dente 3 molar (M) foram testados em oposição ao Plexiglass. Com relação ao desgaste do esmalte dentário (PM+M) segundo o material antagonista, o teste de Kruskal-Wallis evidenciou diferença significativa com p-valor < 0,001 e o teste de Mann-Whitney evidenciou diferença significativa nas comparações PM+M/resina X PM+M/metal (p-valor < 0,001), PM+M/resina X PM+M/cerâmica (p-valor < 0,001) e PM+M/metal X PM+M/cerâmica (p-valor = 0,002). A análise isolada, considerando pré-molares e molares separadamente, encontrou diferença significativa em relação ao desgaste do esmalte dentário no teste de Kruskall-Wallis, porém não detectou diferença significativa no teste de comparação múltipla Mann-Whitney quando comparou o desgaste sofrido pelo PM/metal em relação ao PM/cerâmica. Em relação à dureza Vickers detectou-se diferença significativa da dureza dos materiais no teste de Kruskall-Wallis (p-valor < 0,001) e também no teste de Mann-Whitney nas comparações múltiplas com p-valor = 0,002. Comparando-se a dureza com a perfilometria, observou-se uma correlação estatisticamente significativa (p &#8804; 0,05) na correlação negativa (&#961;= -0,829) entre a dureza do metal como material antagonista e o desgaste do esmalte dentário do dente molar. Os resultados sugeriram que todo material restaurador indireto estudado causou desgaste ao esmalte dentário quando submetido a forças de simulação de abrasão com carga. Embora tenha sido observada correlação entre dureza e resistência à abrasão, essa correlação foi pouco significativa. / The objective of this study was to compare the dental wear of pre-molars (PM) and molars (M) in vitro, and the relationship between dental wear and the Vickers hardness values of the materials used as antagonists in a machine simulating abrasion to produce wear on the teeth tested. The materials used as antagonists were VeraBond II (Ni-Cr alloy), Solidex (composite resin) and IPS Empress 2 (ceramic). Six specimens of each material were prepared for each hardness trial. The specimens were polished under refrigeration, with a 20-min cycle for each grit number. Three dents per quadrant were made in a microhardness tester (HMV-2), under a 19.614 N load for 30 s, for a total of 12 square-base dents with a 136 angle between planes. The abrasion test was performed in an abrasion-simulating machine set to a frequency of 265 cycles/min and 4,4 Hz. The course of the antagonist was 10 mm, at a speed of 88 mm/s. Each tooth was tested against an antagonist material (6 tooth/material pairs per group), in deionized water, under a 5 N load, for 150 min, for a total of 39,750 cycles. Nineteen first pre-molars (PM) and 19 third molars (M) were used, and 12 antagonistic discs were made in each material, for the tests. Each group of six teeth was tested against six antagonists of the same material. Additionally, 1 first pre-molar (PM) and one third molar (M) were tested against Plexiglass. Regarding the dental enamel wear on pre-molars and molars (PM+M) according to the antagonist material, the Kruskal-Wallis test revealed significant differences (p-value < 0.001) and the Mann-Whitney test also revealed significant differences for the following comparisons: PM+M/resin versus PM+M/metal (p-value < 0.001), PM+M/resin versus PM+M/ceramic (p-value < 0.001), and PM+M/metal versus PM+M/ceramic (p-value = 0.002). An analysis conducted with the Kruskall-Wallis test, considering pre-molars (PM) and molars (M) separately, found significant differences in relation to dental enamel wear (PM+M). However, when the multiple-comparison Mann-Whitney test was used, no significant difference was detected between the wear produced in the pre-molar/metal pair and that produced in the pre-molar/ceramic pair. Regarding Vickers hardness, both the Kruskall-Wallis test (p-value < 0.001) and Mann-Whitneys multiple-comparisons test (p-value = 0.002) revealed significant differences between materials. When hardness was compared with the profilometry data, a significant negative correlation was observed (p &#8804; 0.05, &#961; = -0.829) between the hardness of the metal as an antagonist material and the dental enamel wear of the molar tooth. The results suggested that all the indirect restorative materials tested caused wear of the dental enamel when submitted to the forces of simulated abrasion with load. Although a correlation was observed between hardness and resistance to abrasion, this correlation was hardly significant.
212

Análise da tenacidade de uma junta soldada de um aço resistente à abrasão da série 450 HB

Costa, Vagner Machado January 2014 (has links)
Aços resistentes à abrasão possuem uma dureza elevada, sendo amplamente utilizados em aplicações em que o componente ou estrutura é submetido a situações em que é exigida alta resistência mecânica e resistência ao desgaste. Este tipo de aço pode ser aplicado para fabricação de implementos rodoviários, implementos agrícolas, montagem de altos fornos e na indústria de mineração. O presente trabalho visa analisar a influência da baixa temperatura na tenacidade de uma junta de aço resistente à abrasão da série 450HB soldado através do processo ao arco elétrico com arame tubular (Flux-Cored Arc Welding- FCAW). Para tanto foram realizados ensaios de tenacidade ao impacto (Charpy-V) no metal base, metal de solda e ZAC nas temperaturas de 25ºC, 0ºC, -20ºC, -60ºC, -80ºC e -100ºC com o objetivo de levantar a curva de transição dúctil-frágil para cada uma dessas regiões. Também foram realizados ensaios para medição da tenacidade à fratura pelo parâmetro CTOD (Crack Tip Opening Displacement) nas regiões do metal base, metal de solda e ZAC nas temperaturas 25ºC, 0ºC, -20ºC. Adicionalmente foram realizados perfis de microdureza Vickers, dureza Brinell, análise química do metal de base e do metal de solda, caracterização metalográfica (macrografia e micrografias) e análises fractográficas a fim de complementar o estudo da junta soldada. Os resultados mostram melhor desempenho do metal base em relação ao ensaio de impacto, entretanto, o metal de solda apresentou melhores resultados de tenacidade à fratura. A região da ZAC apresentou o pior desempenho entre as regiões em ambos os ensaios de tenacidade realizados. / Abrasion resistant steels have a high hardness, being widely used in applications where the component or structure is subjected to situations where high strength and wear resistance is required. This type of steel can be applied to the production of road equipment, agricultural implements, mounting blast furnaces and in the mining industry. The present work analyzes the influence of low temperature on the toughness of an abrasion resistant steel joint of 450HB series welded through the FCAW (Flux Cored Arc Welding-FCAW) process. It was performed tests of impact toughness (Charpy-V) in the base metal, weld metal and HAZ in the temperatures of 25ºC, 0ºC, -20ºC, -60ºC, -80ºC e -100ºC with the objective to raise the ductile-fragile transition curve for each one of these regions. Tests for measurement of fracture toughness by CTOD (Crack Tip Opening Displacement) parameter in the regions of the base metal, weld metal and HAZ in the temperatures of 25 º C, 0 º C, -20 º C were also performed. In addition, Vickers microhardness profile, Brinell hardness, chemical analysis of the base metal and weld metal, metallographic characterization (macrograph and micrographs) and fractography analysis were performed to complement the study of the welded joint. The results show better performance of the base metal in relation to the impact test, however, the weld metal showed a better fracture toughness. The region of the HAZ showed the worst performance among regions in both toughness tests performed.
213

Avaliação do efeito protetor de fluoretos associados ao polímero bioadesivo carbopol no desgaste erosivo /

Nogueira, Daniele Mara da Silva Ávila. January 2018 (has links)
Orientador: Alessandra Bühler Borges / Coorientador: Taís Scaramucci / Banca: Carlos Rocha Gomes Torres / Banca: Eduardo Bresciani / Banca: Daniela Rios Honório / Banca: Patricia Moreira de Freitas / Resumo: O efeito protetor do flúor contra erosão tem sido relacionado principalmente à formação de depósitos de fluoreto de cálcio e à adsorção de íons flúor na superfície dental, assim hipotetizou-se que a incorporação ao polímero Carbopol 980 poderia potencializar o efeito protetor de soluções fluoretadas no controle do desgaste erosivo do esmalte com a formação de um filme superficial protetor. A proposta foi dividida em duas etapas. A primeira etapa consistiu em um estudo in vitro no qual foi testada a associação do polímero Carbopol ao Fluoreto de sódio (NaF) e Fluoreto de Sódio mais Cloreto de Estanho (NaF + Sn) quanto ao efeito remineralizante e protetor contra a erosão inicial, na presença da película adquirida. O teste de estabilidade de pH (pH stat) foi realizado, tratando cristais de hidroxiapatita com as soluções descritas, a fim de testar o potencial protetor dos componentes isolados ou associados, quanto à dissolução da hidroxiapatita, prevendo assim o potencial protetor das soluções testadas. Em seguida, espécimes cilíndricos em esmalte bovino polido (3 mm diâmetro) foram desmineralizados com ácido cítrico a 0,3% (pH 2,6) por 2 minutos (n=15). Os espécimes foram imersos em saliva humana por 2 horas para formação da película adquirida e foi então realizado o tratamento com as soluções experimentais por 2 minutos [NaF (500 ppm F), NaF + Carbopol (0,1%), NaF + Sn (500 ppm F + 800 ppm Sn), NaF + Sn + Carbopol], água deionizada (controle negativo) e solução comercial (Elmex... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The protective effect of fluoride against erosion has been related mainly to the formation of calcium fluoride deposits and the adsorption of fluoride ions on the dental surface, so it was hypothesized that the incorporation to the Carbopol 980 polymer could potentiate the protective effect of fluoride solutions in the control of the enamel erosive wear with the formation of a protective film. The proposal was divided in two stages. The first stage consisted of an in vitro study in which the association of Carbopol polymer to sodium fluoride (NaF) and sodium fluoride with tin chloride (NaF + Sn) was tested in the presence of acquired pellicle. The ph stat test was used to test the protective potential of these components isolated or associated, in relation to the dissolution of hydroxyapatite, thus predicting the protective potential of the solutions tested. The remineralizing and protective effect against initial erosion measured by microhardness was investigated. Cylindrical polished bovine enamel specimens (3 mm diameter) was prepared and demineralized with 0.3% citric acid (pH 2.6) for 2 minutes (n=15). The specimens were immersed in human saliva for 2 hours to allow acquired pellicle formation and then, treatment with experimental solutions for 2 minutes were performed [NaF (500 ppm F), NaF + Carbopol (0,1%), NaF + Sn (500 ppm F + 800 ppm Sn), NaF + Sn + Carbopol], deionized water (negative control) and comercial mouthrinse (Elmex - positive control). A new immersion in ... (Complete abstract click electronic access below) / Doutor
214

Abrasão de ferro fundido cinzento: aplicação a motores automotivos. / Abrasion of gray cast iron: application to automotive engines.

Luiz Alberto Pereira das Neves Franco 20 October 2015 (has links)
Uma parte significativa das perdas por atrito num motor automotivo resulta da ação de partículas abrasivas. Dentre as fontes possíveis, podem ser citados o próprio meio ambiente - partículas que passam pelo filtro de ar - o desgaste de partes metálicas do motor ou mesmo resíduos de combustão. Essas partículas podem ficar encrustadas em anéis do pistão, ou ficar na interface entre pistão e bloco ou camisa, e são responsáveis por sulcos axiais, na direção do movimento do pistão, observáveis em motores usados. O objetivo deste trabalho foi obter um melhor entendimento dos mecanismos de desgaste relacionados com o sulcamento de camisa/bloco e identificar conjuntos de testes laboratoriais capazes de reproduzi-los sob condições controladas. Amostras de ferro fundido cinzento (FoFo) e de aço AISI 1070 com dureza de matriz próxima daquela encontrada em FoFo (?200HV30) foram submetidas a ensaios de riscamento em tribômetros. Verificou-se que riscos executados com um endentador cônico submetido a cargas na faixa de 20 a 50 mN eram similares aos sulcos observados em camisas ou blocos. Ensaios com outros materiais, como alumínio e latão e mesmo aço de diferentes durezas contribuíram para melhorar o entendimento dos resultados. Não foi observada transição brusca entre mecanismos de abrasão. O cálculo do fator de remoção de material, fab, a partir de perfilometria óptica resultou em valores com dispersão elevada; não foi possível associa-los aos diferentes mecanismos de abrasão observados. Valores obtidos para o coeficiente de atrito no riscamento permitiram fazer uma estimativa inicial de energia gasta nos processos abrasivos do motor. / A significant part of the friction losses in an automotive engine results from the abrasive action of particles. Among possible sources of such particles one can mention the environment - particles that were not retained by the filters - metallic residues from worn parts or even combustion residues. They may be picked up by piston rings and become part of their surfaces or stay loose in the piston/liner interface. Those particles are responsible for axial grooves that are observed in the liners of used engines. The objective of this work was to get a better understanding of the wear mechanisms related to liner/bore grooving and to identify a laboratory testing setup that might reproduce them under controlled conditions. Specimens of Gray Cast Iron (GCI) and of AISI 1070 steel with matrix hardness close to that found in GCI (?200HV30) were submitted to scratch tests in a tribometer. It was found that scratches performed under 20-50 mN indenter load (conical tip) were similar to grooves observed in cylinder liners. Tests with other materials such as aluminum, brass and even steel with different hardness values contributed to a better understanding of the results. No sharp transition between abrasion mechanisms was observed. Calculation of material removal factor fab from optical profilometry resulted in values with a large dispersion; they could not be associated with different abrasion mechanisms. Friction coefficient values obtained from the tests were used to make preliminary estimates of energy consumption due to abrasive processes in the engine.
215

Efeito dos desafios erosivo ou erosivo/abrasivo sobre as estruturas dentárias adjacentes às restaurações realizadas com materiais contendo fluoreto ou cálcio / Effect of erosive and erosive/abrasive challenges on the dental hard tissues adjacent to restorations performed with materials containing fluoride or calcium

Ítallo Emídio Lira Viana 29 January 2018 (has links)
Esse estudo avaliou in vitro o efeito dos desafios erosivo ou erosivo/abrasivo sobre materiais restauradores contendo fluoreto ou cálcio e sobre as estruturas dentárias adjacentes às restaurações realizadas com esses materiais. Fragmentos de esmalte e de dentina bovinos (4 mm × 4 mm × 2 mm), foram incluídos em resina acrílica e planificados. Uma cavidade padrão com dimensões 1,2 mm × 4 mm × 1,5 mm foi preparada nos espécimes, e restaurada de acordo com o material a ser testado: 1. Z350 - resina composta (Filtek Z350, 3M ESPE); 2. VB - compósito experimental contendo apenas vidros de bário; 3. DCPD30% - compósito experimental contendo 10% de vidros de bário e 30% partículas de fosfato di-cálcio di-hidratado (DCPD) funcionalizadas com dimetacrilato de dietilenoglicol (DEGDMA); 4. DCPD60% - compósito experimental contendo 60% partículas de DCPD funcionalizadas com DEGDMA; 5. Beautifil - GIOMER (Beautifil II, Shofu Dental Corporation); 6. Fuji IX - cimento de ionômero de vidro convencional de alta viscosidade (Fuji IX, GC Corporation); 7. Fuji II LC - cimento de ionômero de vidro modificado por resina (Fuji II LC, GC Corporation). Na sequência, os espécimes foram polidos e submetidos a dois tipos de tratamentos: erosão somente (n=10) ou erosão mais abrasão por escovação (n=10). A erosão foi realizada pela imersão dos espécimes em ácido cítrico a 0,3% (pH~2,6) por 5 min, seguido de 60 min de imersão em saliva artificial. Esse procedimento foi repetido 4×/dia, por 5 dias. A escovação foi realizada com uma suspensão de dentifrício padrão (Colgate Total 12 Mint Clean; 1450 ppm F-, como NaF) por 15 s (2 min de exposição total a suspensão de dentifrício), 2×/dia, 30 min após o primeiro e o quarto desafios erosivos. Ao final da ciclagem, a perda superficial (em ?m) do esmalte, da dentina e dos materiais restauradores foi determinada com um perfilômetro ótico. Para cada modelo (erosão e erosão-abrasão), os dados de perda superficial de esmalte, dentina e restauração foram analisados de maneira independente. Os dados foram analisados pelos testes de Kruskal-Wallis e Tukey. O nível de significância utilizado foi de 5%. No modelo de erosão, para esmalte, ambos cimentos ionoméricos apresentaram menor perda superficial do que o compósito Z350, apesar de Fuji II LC não ter se diferenciado significativamente dos grupos Beautifil e DCPD30%. Os outros grupos não foram diferentes de Z350 nem entre si. Para dentina, nenhum dos grupos foi diferente de Z350, com exceção de DCPD60%, o qual apresentou a maior perda superficial. Ambos cimentos ionoméricos apresentaram menor perda do que DCPD30%, Beautifil e DCPD60%. Em relação à restauração, os materiais Z350, Beautifil, VB, DCPD30% apresentaram perda superficial mínima, sem diferenças entre eles. Os cimentos ionoméricos apresentaram os maiores valores de perda, não se diferenciando de DCPD60%. No modelo erosão-abrasão, para esmalte, a menor perda superficial foi observada em Fuji II LC, sem diferença da Beautifil. Os outros grupos não se diferenciaram entre si nem da Beautifil. Para dentina, os grupos DCPD60%, Beautifil, Fuji II LC, Z350 e Fuji IX não se diferenciaram e, apresentaram menor perda superficial do que VB. Os cinco grupos citados também não foram diferentes de DCPD30%, com exceção de Fuji IX. Em relação à restauração, a maior perda foi observada para Fuji IX, sem diferenças de Fuji II LC e Beautifil. DCPD30%, Z350, VB e DCPD60% apresentaram valores mínimos de perda superficial, sem diferenças entre si. Concluiu-se que o cimento ionomérico Fuji II LC foi único capaz de proteger o esmalte adjacente à restauração contra desafios erosivos e erosivos/abrasivos, apesar de ter sido um dos materiais mais susceptíveis ao desgaste por ambos desafios. Para dentina, nenhum material exibiu efeito protetor. / This in vitro study evaluated the effect of erosive or erosive/abrasive challenges on restorative materials containing fluoride and calcium, and on the dental hard tissues adjacent to restorations performed with these materials. Enamel and dentin specimens (4 mm × 4 mm × 2 mm), obtained from bovine incisors, were embedded in acrylic resin, flattened and polished. In the specimens, a standard cavity of 1,2 mm × 4 mm × 1,5 mm was prepared and restored with the following materials: 1. Z350 - Composite resin without actives, Filtek Z350 (3MESPE); 2. VB - experimental composite containing barium glass only; 3. DCPD30% - experimental composite containing 10% of barium glass and 30% of DCPD particles functionalized with DEGDMA; 4. DCPD60% - experimental composite containing 60% of DCPD particles functionalized with DEGDMA; 5. Beautifil - GIOMER (Beautifil II, Shofu Dental Corporation); 6. Fuji IX - high viscosity glass ionomer (Fuji IX, GC Corporation); 7. Fuji II LC - resin-modified glass ionomer (Fuji II LC, GC Corporation). The specimens were polished again and then submitted to one of the two treatments: erosion only (n=10) or erosion plus toothbrushing abrasion (n=10). Erosion was performed by immersing the specimens in 0.3% citric acid solution (p~2.6), for 5 min, followed by 60 min exposure to artificial saliva. This procedure was repeated 4 times a day, for 5 days. Toothbrushing was performed with a slurry of a standard dentifrice (Colgate Total 12 Mint Clean; 1450 ppm F, as NaF), for 15 s (2 min total exposure time to the slurry), 2 times a day, 30 min after the first and last erosive challenges. At the end of cycling, enamel, dentin and restorative material surface loss (in ?m) were determined by optical profilometry. Data were analyzed by the Kruskal-Wallis and Tukey tests. The level of significance was 5%. In the erosion model, for enamel, both ionomeric cements presented lower surface loss than the Z350, although Fuji II LC did not differ significantly from Beautifil and DCPD30% groups. The other groups were no different from Z350 and from each other. For dentin, none of the groups were different from Z350, except for DCPD60%, which presented the highest surface loss. Both ionomeric cements presented lower loss than DCPD30%, Beautifil and DCPD60%. Regarding the restoration, the materials Z350, Beautifil, VB, DCPD30% showed minimal surface loss, with no differences between them. The ionomeric cements had the highest loss values, not differing from DCPD60%. In the erosion-abrasion model, for enamel, the lowest loss was observed for Fuji II LC, with no difference to Beautifil. The other groups showed no difference among them and from Beautifil. For dentin, the groups DCPD60%, Beautifil, Fuji II LC, Z350 and Fuji IX were no significant different and presented lower loss than VB. These five groups were also no different from DCPD30%, except Fuji IX. Regarding the restoration, the highest loss was observed for Fuji IX, with no difference from Fuji II LC and Beautifil. DCPD30%, Z350, VB and DCPD60% presented minimum values of surface loss, without differences between them. It was concluded that Fuji II LC ionomeric cement was the only material able to protect the enamel adjacent to the restoration against erosive and erosive/abrasive challenges, although it was one of the materials that was most susceptible to be wear off by both challenges. For dentin, no material exhibited a significant protective effect.
216

Contribuição ao estudo do desgaste superficial por abrasão em concretos empregados em pisos / Contribution to the study of surface wear by abrasion in concrete used in floors

Silva, Cristina Vitorino da January 2011 (has links)
O desgaste superficial constitui uma das manifestações patológicas mais recorrentes em pisos de concreto. A presença de tal manifestação patológica, proveniente do processo abrasivo, é muito preocupante, uma vez que implica em altos custos para reparar ou substituir este concreto danificado. Portanto, a realização de estudos que buscam avaliar a influência do proporcionamento e tipo de alguns materiais que constituem o traço de concreto, comumente empregado em pisos, é considerada extremamente relevante, no intuito de reduzir a tendência de desgaste dos compósitos. Neste particular, foram avaliados alguns fatores, como o consumo de água (175 l/m³; 190 l/m³; 205 l/m³), o teor de substituição de sílica ativa (0%; 5%; 10%), o teor de adição de microfibras de polipropileno (0 g/m³; 600 g/m³) e o tipo de cimento (CP IV; CP V-ARI). Os ensaios adotados para esta avaliação foram o de resistência à compressão uniaxial, resistência à tração na flexão, dureza superficial por esclerometria, exsudação e resistência à abrasão. Os resultados encontrados mostraram uma influência estatística significativa do tipo de cimento em todas as propriedades avaliadas, sendo que o cimento CP V-ARI apresentou melhor desempenho em comparação ao cimento CP IV, considerando uma mesma relação a/agl (0,53). O fator consumo de água, mantendo-se constante a relação a/agl, mostrou influência significativa na resistência à tração na flexão e na resistência à abrasão dos concretos, e, além disso, foi possível verificar um comportamento semelhante para ambas as propriedades com relação a este parâmetro de controle. Quanto ao teor de substituição de sílica ativa, observa-se que este fator promoveu efeito significativo nas propriedades mecânicas, o que era esperado, na dureza superficial e na exsudação; entretanto, não se verificou influência no desgaste por abrasão dos compósitos cimentícios. Já a adição das microfibras de polipropileno diminuiu significativamente a dureza superficial por esclerometria, sem alterar as demais propriedades analisadas. Os resultados verificados para o desgaste mostraram uma importante relação com as propriedades mecânicas dos concretos. O processo de acabamento como forma de tratamento superficial parece ser efetivo no controle do desgaste por abrasão, uma vez que pode ter minimizado o efeito da exsudação na superfície dos compósitos cimentícios. O consumo de água de 190 l/m³ mostrou ser o teor mais adequado para os materiais e concretos empregados nesta pesquisa. / Surface wear is one of the most frequent pathologies in concrete floors. The presence of such pathological manifestation from the abrasive process is very disturbing, since it implies high costs to repair or replace the damaged concrete. Therefore, studies that seek to evaluate the influence of the proportioning and type of some materials that constitute the mixture proportions of concrete, commonly used on floors, are considered extremely relevant, in order to reduce the tendency of surface wear of composites. In this study, factors such as water consumption (175 l/m³, 190 l/m³, 205 l/m³), replacement content of silica fume (0 %, 5 %, 10 %), addition content of polypropylene fibers (0 g/m³, 600 g/m³) and cement type (CP IV; CP V-ARI) were evaluated. The tests used for this assessment were compressive strength, flexural tensile strength, surface hardness by rebound hammer, bleeding and abrasion resistance. The results showed a significant statistic influence of the cement type on all the properties evaluated, with the cement CP V-ARI presenting a better performance compared to cement CP IV, considering the same w/b ratio (0.53). The water consumption factor, maintaining a constant w/b ratio, showed significant influence on the flexural tensile strength and abrasion resistance of concrete, and, in addition, we could observe a similar behavior for both properties with respect to this parameter of control. Regarding the replacement content of silica fume, it is observed that this factor promoted significant effect on the mechanical properties, which was expected, on the surface hardness and bleeding; however, there was no influence on the abrasion of the cementitious composites. The addition of polypropylene microfibers significantly decrease the surface hardness by rebound hammer, without altering any other property evaluated. The results verified for the wear showed an important relationship with the mechanical properties of concrete. The finishing process as a form of surface treatment seems to be effective in controlling the abrasive wear, since it may have minimized the effect of bleeding on the surface of cementitious composites. The water consumption of 190 l/m³ showed to be the most appropriate content for the materials and concrete used in this research.
217

Análise da tenacidade de uma junta soldada de um aço resistente à abrasão da série 450 HB

Costa, Vagner Machado January 2014 (has links)
Aços resistentes à abrasão possuem uma dureza elevada, sendo amplamente utilizados em aplicações em que o componente ou estrutura é submetido a situações em que é exigida alta resistência mecânica e resistência ao desgaste. Este tipo de aço pode ser aplicado para fabricação de implementos rodoviários, implementos agrícolas, montagem de altos fornos e na indústria de mineração. O presente trabalho visa analisar a influência da baixa temperatura na tenacidade de uma junta de aço resistente à abrasão da série 450HB soldado através do processo ao arco elétrico com arame tubular (Flux-Cored Arc Welding- FCAW). Para tanto foram realizados ensaios de tenacidade ao impacto (Charpy-V) no metal base, metal de solda e ZAC nas temperaturas de 25ºC, 0ºC, -20ºC, -60ºC, -80ºC e -100ºC com o objetivo de levantar a curva de transição dúctil-frágil para cada uma dessas regiões. Também foram realizados ensaios para medição da tenacidade à fratura pelo parâmetro CTOD (Crack Tip Opening Displacement) nas regiões do metal base, metal de solda e ZAC nas temperaturas 25ºC, 0ºC, -20ºC. Adicionalmente foram realizados perfis de microdureza Vickers, dureza Brinell, análise química do metal de base e do metal de solda, caracterização metalográfica (macrografia e micrografias) e análises fractográficas a fim de complementar o estudo da junta soldada. Os resultados mostram melhor desempenho do metal base em relação ao ensaio de impacto, entretanto, o metal de solda apresentou melhores resultados de tenacidade à fratura. A região da ZAC apresentou o pior desempenho entre as regiões em ambos os ensaios de tenacidade realizados. / Abrasion resistant steels have a high hardness, being widely used in applications where the component or structure is subjected to situations where high strength and wear resistance is required. This type of steel can be applied to the production of road equipment, agricultural implements, mounting blast furnaces and in the mining industry. The present work analyzes the influence of low temperature on the toughness of an abrasion resistant steel joint of 450HB series welded through the FCAW (Flux Cored Arc Welding-FCAW) process. It was performed tests of impact toughness (Charpy-V) in the base metal, weld metal and HAZ in the temperatures of 25ºC, 0ºC, -20ºC, -60ºC, -80ºC e -100ºC with the objective to raise the ductile-fragile transition curve for each one of these regions. Tests for measurement of fracture toughness by CTOD (Crack Tip Opening Displacement) parameter in the regions of the base metal, weld metal and HAZ in the temperatures of 25 º C, 0 º C, -20 º C were also performed. In addition, Vickers microhardness profile, Brinell hardness, chemical analysis of the base metal and weld metal, metallographic characterization (macrograph and micrographs) and fractography analysis were performed to complement the study of the welded joint. The results show better performance of the base metal in relation to the impact test, however, the weld metal showed a better fracture toughness. The region of the HAZ showed the worst performance among regions in both toughness tests performed.
218

Avaliação da superfície do esmalte após diferentes tempos de jateamento de óxido de alumínio indicados para a colagem de braquetes / Evaluation of enamel surface after different times of aluminium oxide sandblasting indicated for bracket bonding

Lilian Rocha Gabarrone 01 July 2016 (has links)
Objetivo: avaliar e comparar os efeitos do jato de óxido de alumínio sobre a superfície do esmalte, quando aplicados por tempos diferentes. Material e métodos: 110 pré-molares foram obtidos por meio de doações do Banco de Dentes da FOUSP. Os dentes foram divididos aleatoriamente em 5 grupos (n=22) para a aplicação de jato de óxido de alumínio por diferentes períodos de tempo. Nos grupos A, B, C, D e E o jato de óxido de alumínio de 50 ?m foi aplicado, respectivamente, por 01, 03, 05, 07 e 10 segundos. Avaliações quantitativas da superfície do esmalte foram realizadas pelas análises das alterações do perfil e da rugosidade (Sa) da superfície vestibular antes e após o seu jateamento, por meio do medidor de perfil Form Talysurf Intra (Taylor Hobson - AMETEK Inc, Pennsylvania) e do interferômetro a laser Talysurf CCl Lite (Taylor Hobson - AMETEK Inc, Pennsylvania), respectivamente. Uma avaliação qualitativa da superfície do esmalte foi realizada por meio da microscopia eletrônica de varredura (MEV). Para esta última análise, um exemplar de cada grupo foi selecionado aleatoriamente para que as superfícies de esmalte jateadas fossem devidamente preparadas para as suas leituras. Os dados quantitativos foram comparados pelo teste ANOVA, seguido do teste post hoc de Tukey, adotando-se um nível de significância de 5% (p= 0,05). Resultados: observou-se maior alteração do perfil e da rugosidade conforme se aumentou o tempo de aplicação do jato de óxido de alumínio. Porém, com relação à alteração do perfil, diferenças estatisticamente significantes foram observadas somente entre o grupo A (1s) quando comparado aos grupos D (7s) e E (10s), e entre o grupo B (3s) quando comparado com o grupo E (10s). Quanto à rugosidade, verificou-se diferença estatisticamente significante apenas entre o grupo E (10s) quando comparado aos demais grupos. As cinco imagens obtidas pelo microscópio eletrônico de varredura (MEV) demonstraram bastante semelhança entre si, com padrão de condicionamento marcado por picos e vales, porém as imagens dos esmaltes jateados por 1 e 3 segundos apresentaram esses picos e vales em menor quantidade. Conclusão: a perda de estrutura dentária e a rugosidade da superfície do esmalte aumentaram conforme se aumentou o tempo de aplicação do jato de óxido de alumínio; a aplicação do jato de óxido de alumínio por 1 e 3 segundos promove menos perda de estrutura de esmalte do que quando se jateia o esmalte por 10 segundos; maior rugosidade pode ser obtida com o jateamento de óxido de alumínio por 10 segundos; entretanto, o aspecto morfológico do esmalte dentário é bastante similar, independentemente do tempo de jateamento. / Objective: To evaluate and compare the effects of aluminium oxide sandblasting on enamel surface when applied at different times. Materials & Methods: 110 premolars were obtained from the local tooth bank. The teeth were randomly divided into 5 groups (n = 22) for application of aluminium oxide sandblasting at different times. In Groups A, B, C, D and E, sandblasting with 50-?m aluminium oxide particles was applied for 01, 03, 05, 07 and 10 seconds, respectively. Quantitative assessments of enamel surface were performed by analysing changes in the profile and roughness (Sa) of the buccal surface before and after sandblasting application by using a profile gauge (Form Talysurf Intra, Taylor Hobson - AMETEK Inc, Pennsylvania, USA) and a laser interferometer (Talysurf CCl Lite, Taylor Hobson - AMETEK Inc, Pennsylvania, USA), respectively. A qualitative assessment of enamel surface was performed by means of scanning electron microscopy (SEM). For this latter analysis, a sample of each group was randomly chosen so that the sandblasted enamel surfaces could be adequately prepared to be evaluated. The quantitative data were compared by using ANOVA test, followed by post-hoc Tukey\'s test, at a significance level of 5% (P = 0.05). Results: Profile and roughness were found to be more altered as the sandblasting application time increased. With regard to the profile, however, statistically significant differences were found only in Group A (1s) compared to Groups D (7s) and E (10s), as well as in Group B (3s) compared to Group E (10s). With regard to the roughness, statistically significant difference was also observed only in Group E (10s) compared to the other groups. Five SEM images were demonstrated to be very similar to each other, with the conditioning pattern being marked by peaks and valleys, although SEM images of enamel blasted for 1 and 3 seconds showed peaks and valleys in lesser amount. Conclusion: Both loss of dental structure and enamel roughness increased as the time for application of aluminum oxide sandblasting also increased; application of aluminum oxide sandblasting for 1 and 3 seconds produced less loss of enamel structure compared to the 10-second application; more roughness can be obtained with application of aluminum oxide sandblasting for 10 seconds; however, the morphological aspect of the tooth enamel is very similar, regardless of the application time.
219

Reciclagem de vidro laminado: utilização na fabricação de isolantes e vernizes com alta resistência à abrasão para pisos de madeira. / Windshield recycling: in the fabrication of isolators and varnishes with high abrasion resistance for wood flooring.

Isabella Marini Vargas 30 March 2007 (has links)
Neste trabalho apresenta-se uma alternativa para utilização de vidros laminados provenientes de rejeitos industriais ou pós-consumo. Reciclando o vidro laminado, por meio de uma série de moagens, pode-se obter dois tipos de rejeitos: vidros de partículas pequenas (200 e 325 mesh), que não conseguem ser reaproveitados pela indústria vidreira, e filme de poli(vinil butiral) - PVB - impregnado com uma pequena quantidade de carga, que tem como destino os aterros. No presente estudo, esses dois resíduos foram aproveitados na fabricação de vernizes curados por radiação ultravioleta empregados para proteção de pisos de madeira. O filme de PVB foi utilizado na formulação de um isolante, em razão de sua alta flexibilidade e boa aderência à madeira, e o vidro de baixa granulometria foi empregado como carga nos vernizes chamados de alto tráfego para o aumento da resistência à abrasão dos mesmos (propriedade fundamental de vernizes para pisos de madeira). Pelos resultados obtidos, verificou-se que o isolante preparado com o filme de PVB em solução alcoólica e misturado a um monômero acrílico trifuncional, como o trimetilolpropano triacrilato (TMPTA), quando aplicado sobre pisos de madeira, obteve-se bons resultados de aderência, arrancamento e flexibilidade, podendo assim substituir os isolantes utilizados atualmente, produtos com cura por radiação ultravioleta, em base aquosa, e que apresentam alto custo por serem preparados com resinas importadas. Foi observado que quanto maior a quantidade de solução de PVB, melhor a flexibilidade do filme e, conseqüentemente, melhor a resistência ao arrancamento do revestimento. Os vidros de baixa granulometria apresentaram resultados muito satisfatórios quando utilizados como carga nos vernizes de alto tráfego, especialmente ao se combinarem com o óxido de alumínio (carga atualmente utilizada nesses sistemas), aumentando ainda mais a resistência à abrasão dos vernizes e também a estabilidade dos vernizes (quanto à sedimentação e à geleificação). Para todas as combinações de cargas preparadas neste trabalho foram bons os resultados obtidos, podendo-se optar pela utilização daquelas com maior quantidade de vidro, uma vez que este, por tratar-se de um resíduo, torna tais combinações mais econômicas. / The present work features an alternative for the utilization of the windshield after its use. The recycling of the laminated glass, through a series of grindings, make possible to obtain two kinds of materials: glasses of small particles (200 and 325 mesh), that cannot be recovered in the glass industry, and a poly(vinyl butiral) - PVB - sheet impregnated with a small amount of filler, that has as final disposal the sanitary landfill. In this study these two materials were introduced in the formulation of ultraviolet curing varnishes used to the protection of wood flooring. The film of PVB was used in the formulation of a primer, due to its high flexibility and good adherence to the wood, and the glass of low granulometry was used as a filler in the so-called high traffic varnish, to increase the abrasion resistance (main property of these varnishes). The results obtained showed that the primer prepared with the PVB sheet in alcoholic solution, mixed with a trifunctional acrylic monomer, like TMPTA, when applied on wood flooring, obtained good results of adherence, scrape adhesion, flexibility and stability and could substitute the primers used nowadays that are UV curing products, however water based ones, and that has a high cost because of the imported resins that are used in their formulations. It was observed that larger the amount of solution of PVB, better the flexibility of the film and, consequently, better its scrape adhesion. The glasses of low granulometry also presented very satisfactory results when used as fillers in the high traffic varnishes, mainly when in combination with aluminium oxide (filler used in these systems), increasing more the abrasion resistance of the varnishes and also their stability (the sedimentation and geleification have showed better results). To all filler combinations studied in this work the results were good and the best one can be the ones that presented the largest amount of glass, since as a residue, make these combinations more economical.
220

Avaliação in situ do efeito do gel contendo euclea natalensis na superfície dentária, antes do desafio erosivo seguido ou não da abrasão / Evaluation in situ of the gel containing natalensis euclea effect on the tooth surface before the erosive challenge with or without abrasion

Cheila Nilza Hamina Xavier 29 November 2011 (has links)
Este estudo avaliou in situ a ação do gel contendo euclea natalensis na redução da erosão associada ou não abrasão em esmalte e dentina humanos. O estudo foi realizado em duas fases cruzadas de cinco dias cada (SG - sem gel e CG - com gel) nas quais 10 voluntários utilizaram placas palatinas com 4 blocos de esmalte e 4 blocos de dentina, distribuídos em duas fileiras horizontais contendo 4 blocos, correspondendo aos subgrupos: erosão (Eros); erosão + abrasão (30min) (Eros + Abras). Em fases alternadas metade dos voluntários teve a aplicação do gel em todos espécimes do aparelho e na outra metade os espécimes não sofreram tratamento nenhum. O gel foi aplicado durante 5 minutos, sendo o mesmo removido após este tempo. Na etapa experimental os aparelhos foram imersos em refrigerante 4x ao dia, por 5 minutos. A seguir o aparelho foi colocado na boca por 30 minutos. Após este período os voluntários escovaram 4 espécimes da fileira Eros + Abras e recolocaram o aparelho. A outra fileira (Eros) não foi escovada. A análise da perda de estrutura dentária foi realizada por meio de teste de perfilometria e microdureza. Foi utilizada a análise de variância (ANOVA) a 2 critérios (presença ou ausência da aplicação do gel) de acordo com cada substrato e o teste TUCKEY (p<0,05). Não houve associação entre perda de dureza e condições ou grupos testados (p>0,05). O desgaste dentário médio nos blocos de esmalte para o grupo CG foi de 12,86µm eros e 12,13µm eros+abras e para os blocos de dentina foi de 5,95µm eros e 6,16µm eros+abras. A média de desgaste dentário para o grupo SG, em blocos de esmalte foi de 14,08µm eros e 16,29µm eros+abras e, nos blocos de dentina foi de 13,64µm eros e 12,63µm eros+abras. Houve diferença significativa entre os grupos (p<0,05). Concluiu-se que o gel contendo euclea natalensis é capaz de reduzir o desgaste associado ou não a abrasão, independente do tipo de substrato, esmalte ou dentina. / This study investigated the action of in situ gel containing euclea natalensis on reducing erosion associated or not with abrasion in the human enamel and dentin. The study was performed into two phases crossed in five days each (WOG-without gel and WG- with gel) in which ten volunteers used acrylic palatal appliances with four blocks of enamel and four dentin, distributed in two horizontal rows containing four blocks, corresponding to the subgroups: erosion (Eros); erosion + abrasion (30min) (Eros + Abras). In alternating phases half the volunteers had the applying the gel at all specimens. And the other half of the volunteers have not suffered any treatment. The gel was applied during 5 minutes, being removed after this time. In stage experimental, the blocks were subjected to erosion by immersion of the appliances into soft drink for five minutes, 4 times a day. The appliance was then replaced into the mouth for 30 minutes. After this period the volunteers brushed row (eros+abrasion) and replaced into the mouth. The row (eros) was not brushed. The analysis of the dental structure were determined using profilometry and microhardness tests. ANOVA by two criteria (presence or absence of application of gel) in agreement with each the substrate and Tukey test were applied (p <0.05). Microhardness and conditions or groups tested were not found association (p> 0.05). The mean wear in enamel blocks was 12.86µm eros and 12.13µm eros + abras in the WG group and in dentin blocks was 5.95 µm eros and 6.16µm eros+ abras. The mean wear in enamel blocks was 14.08µm eros and 16.29µm eros+abras for the WOG group and in dentin blocks was 13.64µm eros and 12.63µm eros + abras. There was significant difference between groups (p <0.05). It concluded that the gel containing Euclea Natalensis can reduce erosion with or without abrasion, independently of the substrate type, enamel or dentin.

Page generated in 0.2438 seconds