• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 152
  • 51
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • Tagged with
  • 211
  • 211
  • 146
  • 104
  • 64
  • 63
  • 57
  • 42
  • 41
  • 26
  • 25
  • 25
  • 25
  • 24
  • 18
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
181

Avaliação in vitro da citotoxicidade de resinas acrílicas para reembasamento baseadas em uma nova formulação /

Costa, Cristiane Campos. January 2009 (has links)
Resumo: O objetivo deste estudo foi determinar a citotoxicidade in vitro de duas resinas reembasadoras experimentais autopolimerizáveis contendo alta concentração de agentes de ligação cruzada, etilenoglicol dimetacrilato (EGDMA) e 1,4-butanodiol dimetacrilato (BDMA) comparadas com uma resina reembasadora comercial (Tokuyama Rebase Fast II). Foram confeccionados corpos-de-prova em forma de discos das três resinas acrílicas reembasadoras rígidas sob condições assépticas. Os fibroblastos (L929) foram cultivados em placas com 96 compartimentos e incubadas por 24 h em meio de cultura Eagle. Os extratos foram preparados, colocando-se três amostras de cada resina em frascos de vidro estéreis com 9 mL de meio de Eagle e incubadas a 37º C por 24 h. O efeito citotóxico dos extratos foram avaliados utilizando os testes de incorporação do 3H-timidina e MTT, que refletem os níveis de síntese de DNA e metabolismo celular, respectivamente. Os dados foram analisados estatisticamente, utilizando análise de variância (P<0.05). Para o teste de incorporação do 3H-timidina, não foram observadas diferenças significativas (P>0.05) entre os materiais. A média da quantidade do isótopo incorporado no DNA celular para todas as resinas acrílicas foi estatisticamente menor do que para o controle. Todas as resinas acrílicas foram classificadas pelo teste de incorporação do 3Htimidina como moderadamente citotóxicas. Da mesma forma, para o teste do MTT, não foi encontrada diferença significativa para a citotoxicidade entre os materiais (P>0.05). Quando a citotoxidade foi comparado com o grupo controle, todas as resinas foram classificadas entre não citotóxicas e discretamente citotóxicas pelo teste do MTT. Assim, conclui-se que a incorporação dos agentes de ligação cruzada, EGDMA e BDMA não influenciaram significativamente sobre a citotoxicidade observada. Não houve diferença... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The aim of this study was to determine the cytotoxicity in vitro of two trials autopolymerizing reline systems made with higher concentration of cross-linking agents, EGDMA and BDMA compared to a commercial reline resin. Sample disks of the three hard reline acrylic resins were fabricated under aseptic conditions. The Fibroblast L929 cells were cultured in 96-well plates and incubated for 24 h in Eagle's medium. Eluates were prepared by placing three samples into a sterile glass vial with 9 mL of Eagle's medium and incubating at 37ºC for 24 h. The cytotoxic effect from the eluates was evaluated using the 3H-thymidine incorporation and MTT assays, which reflect DNA synthesis levels and cell metabolism, respectively. The data were statistically analyzed by using the one-way analysis of variance (P<.05). With the 3H-thymidine incorporation assay, no significant differences (P > .05) were found between the materials. The mean quantity of isotope incorporated into cellular DNA for all acrylic resins was statistically smaller than for the control. All acrylic resins were graded by the 3Hthymidine incorporation assay as moderate cytotoxic. Similarly, with the MTT assay, no significant difference in cytotoxicity was found between the materials (P > .05). When the cytotoxicity was compared with control group, all resins assay were between non cytotoxic and slight cytotoxic by the MTT. The incorporation of cross-linking agents, EGDMA and BDMA had no significant influence on the cytotoxicity observed. There was no cell viability difference between all materials in both assays. / Orientador: Eunice Teresinha Giampaolo / Coorientador: Iracilda Zeppone Carlos / Banca: Renata Cristina Silveira Rodrigues Ferracioli / Banca: Iracilda Zeppone Carlos / Mestre
182

Efeito do reembasamento da ciclagem mecânica e da desinfecção por microondas sobre a força máxima de fratura, deformação, energia de ruptura e estabilidade dimensional de bases de prótese /

Seó, Rosangela Seiko. January 2006 (has links)
Orientador: Carlos Eduardo Vergani / Banca: Ana Lucia Machado / Banca: Marco Antonio Compagnoni / Banca: Marcelo Ferraz Mesquita / Banca: Rodrigues Nunes Rached / Resumo: O estudo avaliou o efeito do reembasamento, da ciclagem mecânica, da ciclagem térmica e da desinfecção por microondas sobre a força máxima de fratura, a deformação, a energia de ruptura e a estabilidade dimensional de bases de prótese. Os resultados evidenciaram que as variações intra-orais tais como os estresses térmico e mecânico aumentaram a degradação e diminuíram a vida útil das bases de prótese intactas e reembasadas com o material reembasador TRFII. A desinfecção por microondas produziu uma contração significativa das bases de prótese intactas e aquelas reembasadas com os materiais NTL e K. A desinfecção por microondas não afetou os valores de força máxima de fratura das bases de prótese intactas ou reembasadas com diferentes materiais reembasadores; porém, os valores de energia de ruptura e deformação das bases de prótese reembasadas com TR e NTL foram significativamente reduzidas após os ciclos de desinfecção por microondas e armazenamento em água por 7 dias. / Abstract: This study investigated the effect of relining, thermal stress, mechanical stress and microwave disinfection on the maximum fracture load, deflection at fracture, fracture energy and dimensional stability of intact denture bases and those relined with four autopolymerizing reline resins. Thermal and mechanical stresses adversely affect the strength of intact and/or relined denture bases; however, effects vary based upon the relining material used. Microwave disinfection produced increased shrinkage of intact specimens and those relined with New Truliner and Kooliner. The strength of the denture bases relined with New Truliner was not significantly affected by any of the experimental conditions, but comparing the control groups, New Truliner exhibited the lowest maximum fracture load values. The maximum fracture load of specimens was not affected by microwave disinfection. Microwave disinfection and water storage for 7 days decreased the deflection at fracture and fracture energy values of specimens relined with Tokuso Rebase Fast and New Truliner. The deflection at fracture and fracture energy values of specimens relined with Tokuso Rebase Fast and New Truliner were affected by microwave disinfection. / Doutor
183

Efeito de tempos de simulação do intemperismo natural na deformação permanente dos materiais reembassadores resilientes e na resitencia a tração da sua união com a resina acrilica / Effect of accelerated ageing on the permanet deformation and tensite bond strenght of auto-polymerizing soft dentures liners

Takahashi, Jessica Mie Ferreira Koyama 02 May 2009 (has links)
Orientador: Marcelo Ferraz Mesquita / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-12T19:45:53Z (GMT). No. of bitstreams: 1 Takahashi_JessicaMieFerreiraKoyama_M.pdf: 3156848 bytes, checksum: e45be536e6455880f4523ac84c0d2894 (MD5) Previous issue date: 2009 / Resumo: O objetivo neste estudo foi avaliar o efeito de diferentes tempos de envelhecimento acelerado realizado por meio da simulação do intemperismo natural, sobre as propriedades de deformação permanente e resistência à tração da união de dois materiais resilientes usados como forradores de base de prótese, sendo um à base de resina acrílica e outro à base de silicone. Para o ensaio de resistência à tração da união, os materiais reembasadores foram unidos a dois blocos de resina acrílica (9 X 9 X 40 mm) utilizada para a confecção de bases de próteses totais. Para o ensaio de deformação permanente, os corpos-de-prova de reembasador resiliente apresentaram 19 mm de altura e 12,7 mm de diâmetro. Os corpos-de-prova (n=10) foram submetidos ao envelhecimento acelerado nos tempos 2, 4, 8, 16, 32 e 64 ciclos por meio da simulação do intemperismo natural. O ensaio de resistência à tração da união foi realizado em máquina de ensaios EMIC DL-500 MF com velocidade média de 5 mm/min, sendo avaliado também o tipo de falha de união (adesiva, coesiva ou mista). Para o ensaio de deformação permanente foi utilizado aparelho mecânico descrito na especificação no 18 da A.D.A., com carga compressiva de 750 gf. Foi realizada análise estatística utilizando o teste Kruskall-Wallis associado ao método de Dunn, para comparação entre os materiais no mesmo intervalo de envelhecimento, e o teste Mann-Whitney para comparação do efeito dos tempos de envelhecimento em cada material. Avaliando os resultados obtidos após a análise estatística, pôde-se observar que o reembasador à base de silicone apresentou menor porcentagem de deformação permanente (p<0,0001) e maior resistência à tração (p<0,0001) que o reembasador à base de resina acrílica em todos os intervalos de envelhecimento. E que a simulação do intemperismo natural não afetou a deformação permanente (p=0,90) e a resistência à tração (p=0,15) do reembasador à base de silicone, mas reduziu a porcentagem de deformação permanente e aumentou a resistência à tração do material à base de resina acrílica (p<0,05). Os resultados demonstraram que o reembasador resiliente à base de silicone é menos susceptível à cargas compressivas, pois apresentou melhor recuperação elástica, menor deformação permanente e maior resistência à tração que o à base de resina acrílica. E que o envelhecimento acelerado, afeta as propriedades de deformação permanente e resistência à tração do material reembasador à base de resina acrílica. / Abstract: This study aimed to evaluate the effect of different times of accelerated ageing over the properties of permanent deformation and tensile bond strength of two soft liners used on prostheses relining. The soft liners studied were auto-polymerizing and acrylic resin and silicone based. The materials were processed according the manufacturers' instructions. The resilient liner specimens (9 X 9 X 3 mm) for tensile bond strength were processed between 2 acrylic resin blocks (9 X 9 X 40 mm). The resilient liner specimens for permanent deformation test were 19 mm height and 12.7 mm diameter. The specimens (n=10) were submitted to accelerated ageing process during 2, 4, 8, 16, 32 and 64 cycles. Tensile bond strength was performed with crosshead speed of 5 mm/min using a testing machine EMIC DL-500 MF. Permanent deformation was performed with an apparatus described on specification no 18 of A.D.A., with compressive load of 750 gf. Statistical analysis was performed using Kruskall-Wallis and Dunn tests to compare materials on the same ageing period and Mann-Whitney test to compare the effect of different ageing periods on each material. The results obtained after statistical analysis demonstrated that the silicone based reliner presented lower percentage of permanent deformation (p<0.0001) and higher tensile bond strength (p<0.0001) than the acrylic resin based reliner in all the ageing intervals. And that the accelerated ageing process did not affect the permanent deformation (p=0.90) and tensile bond strength (p=0.15) of the silicone based reliner, but reduced the percentage of permanent deformation and increased tensile bond strength of the acrylic resin based reliner (p<0.05). Results demonstrated that silicone based reliner is less susceptible to compressive loads, presenting better elastic recovery, lower permanent deformation and higher tensile bond strength. And that accelerated ageing affected only acrylic resin based reliners. / Mestrado / Protese Dental / Mestre em Clínica Odontológica
184

Propriedades físicas da resina acrílica para coroas provisórias em função de diferentes técnicas de polimerização (rugosidade, porosidade, microdureza, sorção e solubilidade) / Physical properties of acrylic resin for provisional crowns under different curing techniques

Daniel Afonso Hiramatsu 27 November 2009 (has links)
Foi realizada uma avaliação in vitro da influência de três variáveis sobre a rugosidade, porosidade, microdureza, sorção e solubilidade de uma resina acrílica para coroas provisórias: ambiente de polimerização (ar/água), temperatura e pressão de acordo com 4 técnicas de manipulação, diretas e indiretas. Os corpos de prova foram confeccionados utilizando a resina poli (metilmetacrilato) (PMMA) Dencorcor nº 66. A rugosidade de superfície (Ra) foi verificada por um rugosímetro/perfilômetro. Na análise da porosidade foi utilizado um método quantitativo de contagem dos poros por área delimitada utilizando um microscópio comparador. A análise da microdureza foi feita antes e depois da simulação do desafio ácido ocorrido na cavidade bucal. Para a análise de sorção e solubilidade os espécimes foram submetidos a ciclos de hidratação e ressecamento e através da comparação entre as pesagens iniciais e finais foi possível estabelecer os resultados. Os resultados de Rugosidade foram favoráveis às técnicas indiretas (grupos I e II) com médias de Ra=0,141m e 0,181m, respectivamente, seguidos pelas técnicas diretas (grupos III e IV) com Ra=0,373m e 0,908m. Os resultados de porosidade foram de 0,8 poros por área delimitada para o grupo I, seguido do grupo II com 0,9 poros; grupo III com 7,2 poros e grupo IV com 124 poros. Os resultados de microdureza para todos os grupos evidenciaram diminuição da dureza após a ciclagem ácida com valores que diminuíram de 14,12 para 13,03 no grupo I; de 14,06 para 12,93 no grupo II; de 13,73 para 12,71 no grupo III e de 13,47 para 12,65 no grupo IV. Os resultados de sorção foram de 1,807% para o grupo I; 1,817% para o grupo II; 2,068% para o grupo III e 2,227% para o grupo IV. E os resultados de solubilidade foram 0,036% para o grupo I; 0,054% para o grupo II; 0,184% para o grupo III e 0,212% para o grupo IV. Os maiores valores de rugosidade e porosidade foram alcançados pelos corpos-de-prova confeccionados pelas técnicas diretas e os menores valores se deram nos corpos-de-prova confeccionados segundo as técnicas indiretas e pela técnica do pincel. O desafio ácido reduziu a dureza da resina acrílica, porém não houve diferença nos testes de dureza entre os diferentes grupos. Os espécimes confeccionados pelas técnicas indiretas apresentaram menor sorção e solubilidade quando comparadas às técnicas diretas. Portanto, as técnicas indiretas de confecção de coroas provisórias devem ser preferidas às técnicas diretas. / An in vitro evaluation of the influence of three variables (polymerization medium (air/water), temperature and pressure) on roughness, porosity, microhardness, sorption and solubility of an acrylic resin for provisional crowns was conducted according to 4 techniques (direct and indirect). The samples were prepared using a poly (methylmethacrylate) (PMMA) resin Dencor color No 66. The surface roughness (Ra) was evaluated with a perfilometer. Porosity was analyzed according a quantitative method of counting number of pores per area by using a comparator microscope. Microhardness readings were made before and after acid challenge simulation as in the oral cavity. For sorption and solubility analysis, specimens were subjected to successive cycles of dampening and dehydration to make comparisons of the initial and final weights. Roughness results were lower for indirect techniques (groups I and II) with averages of Ra = 0.141m and 0.181m, respectively, followed by direct techniques (groups III and IV) with Ra = 0.373m and 0.908m. Porosity results were 0.8 pores per area for the group I, 0.9 pores for group II, 7.2 pores for group III and 124 pores for group IV. All groups showed a decrease in hardness after acid cycling with values that ranged from 14.12 to 13.03 in group I, 14.06 to 12.93 in group II, 13.73 to 12.71 in group III, and 13.47 to 12.65 in group IV. Sorption results were 1.807% in group I, 1.817% in group II, 2.068% in group III, and 2.227% in group IV. Solubility results were 0.036% in group I, 0.054% in group II, 0.184% in group III and 0.212% in group IV. Higher values of roughness and porosity were obtained by specimens made by direct technique and lower values were achieved with specimens made by indirect technique and brush technique. The acid challenge statistically decreased hardness of the acrylic resin, but there was no statistical difference among different groups. The specimens prepared by indirect techniques showed lower sorption and solubility when compared to direct techniques. The indirect techniques for making provisional crowns should be preferred compared to direct techniques.
185

Avaliação da alteração de cor e rugosidade média superficial de resinas acrílicas usadas em base de próteses após imersão em desinfetantes químicos e bebidas / Evaluation of the color alteration and superficial roughness of the denture base acrylic resins after immersion in chemical didinfectants and beverages

Flávio Henrique Carriço Nogueira Fernandes 24 September 2009 (has links)
Pacientes submetidos a procedimento protéticos estão expostos a microorganismos patogênicos podendo ocorrer desenvolvimento de doenças e infecção cruzada entre pacientes e equipe odontológica.As próteses devem ser desinfetadas com substâncias que não provoquem alterações nas propriedades mecânicas e físicas principalmente em associação com a ingestão de bebidas com teor alcoólico ou baixo pH. O objetivo desse estudo foi avaliar a rugosidade média superficial (Ra) e estabilidade de cor de resinas acrílicas(Lucitone 550, QC-20 e Vipi-Wave), empregadas na confecção de bases para próteses totais, removíveis, overdentures e próteses protocolos sobre implantes após imersão em desinfetantes químicos (hipoclorito de sódio 1% e ácido peracético 2%) por 30 e 60 minutos, e após desinfecção por 30minutos seguida de imersão em bebidas com e sem teor alcóolico (vinho, suco de uva, chá e aguardente). Foram confeccionados 60 corpos-de-prova de cada marca comercial de resina, sendo divididos em 2 grupos, referentes aos desinfetantes químicos. Após os procedimentos de acabamento e polimento dos corpos-de-prova, foram realizadas as mensurações iniciais (t=0) de rugosidade e cor, e a seguir dez corpos-de-prova de cada marca comercial de resina foram imersos em hipoclorito de sódio e dez em ácido peracético, durante 30 e 60 minutos, sendo realizadas as mensurações após cada período de imersão. Esses dados foram, posteriormente submetidos à análise estatística. Quarenta corpos-de-prova de cada tipo de resina foram imersos em hipoclorito de sódio e ácido peracético por 30min, a seguir foram realizadas as mensurações de rugosidade e cor, e a divisão em subgrupos referentes às bebidas. Os corpos-de-prova foram lavados com água destilada, secos com lenços de papel e imersos em vinho(n=5), suco de uva(n=5), chá (n=5) e aguardente (n=5) por 2 horas. Após as mensurações, os corpos-de-prova foram imersos em água destilada e mantidos por 24 horas, decorrido esse período foram realizadas as mensurações de rugosidade e cor. Os corpos-de-prova eram imersos diariamente nas bebidas por 2 horas e as mensurações subseqüentes de rugosidade e cor eram realizadas após 168hs (7dias), 336hs (14dias) e 504hs (21dias) de imersão nas mesmas bebidas.Os dados foram analisados estatisticamente pela Análise de Variância e testes complementares de Tukey e Scheffé. Foi evidenciado aumento da Ra após 30 minutos de imersão nos desinfetantes em todas as resinas, com QC-20 apresentando os maiores valores de Ra e Vipi-Wave os menores. Lucitone 550 apresentou maior Ra após imersão em vinho, suco de uva e aguardente e Vipi-Wave após imersão em chá. Após 60minutos de imersão nos desinfetantes todas as resinas apresentaram alteração de cor estatisticamente significante. Os corpos-de-prova imersos em vinho apresentaram os maiores valores de alteração de cor após 336hs (14dias), enquanto os imersos em suco de uva apresentaram alterações de cor leves após 168hs (7dias), 336hs (14dias) e 504hs (21dias), e os imersos em aguardente e chá não apresentaram alterações de cor clinicamente significantes. Conclui-se que desinfecção em hipoclorito de sódio 1% e ácido peracético alterou as propriedades de rugosidade média e cor das resinas avaliadas, e dentre as bebidas, vinho e suco de uva foram as que propiciaram maior alteração de cor. / Patients submitted to prosthetic procedures are exposed to pathogenic microorganisms, and the development of diseases and crossed infection may occur between patients and the dental team. Dentures must be disinfected with substances that do not cause changes in the mechanical and physical properties, particularly in association with the ingestion of beverages with alcohol concentration or low pH. This study evaluated the surface roughness (Ra) and color stability of acrylic resin colors (Lucitone 550, QC-20 and Vipi-Wave), used for fabricating bases for complete, removable dentures, overdentures and prosthetic protocol after immersion in chemical disinfectants (1% sodium hypochlorite and 2% peracetic acid) for 30 and 60 minutes, and after disinfection, followed by immersion in beverages (wine, grape juice, tea and brandy) for 30minutes. Sixty specimens were made of each commercial brand of resin composite, and divided into 2 groups according to the chemical disinfectants. After the test specimens had undergone the finishing and polishing procedures, the initial color and roughness measurements were taken (t=0), and after this, tem test specimens of each commercial brand of resin composite were immersed in sodium hypochlorite and ten in peracetic acid, for 30 and 60 sixty minutes, with measurements being taken after each immersion period. Afterwards, these data were submitted to statistical analysis. Forty test specimens of each type of resin were immersed in sodium hypochlorite and peracetic acid for 30 min, after which roughness and color measurements were taken, and specimens were divided into subgroups according to the beverages. The specimens were washed with distilled water, dried with paper towels and immersed in wine (n=5), grape juice (n=5), tea (n=5) and brandy (n=5) for 2 hours. After being measured, the test specimens were immersed in distilled water and kept there for 24 hours. When this period elapsed, roughness and color were measured. The test specimens were immersed for 2 hours daily, and the subsequent roughness and color measurements were taken 168 hrs (7days), 336 hrs (14days) and 504 hrs (21days) after immersion in the same beverages. The data were statistically analyzed by the Analysis of Variance and Tukey and Scheffé complementary tests. There was evidence of an increase in Ra after 30 minutes immersion in the disinfectants in all the resins, with QC-20 presenting the highest Ra values, and Vipi-Wave the lowest. The Lucitone 550 resin presented the highest Ra after immersion in wine, grape juice and brandy, and Vipi-Wave after immersion in tea. After 60 minutes immersion in the disinfectants all the resins presented statistically significant color alteration. The test specimens immersed in wine presented the highest color alteration values after 14 days, while those immersed in grape juice presented slight color alterations after 168 hrs (7days), 336hrs (14days) and 504hs (21days), and those immersed in brandy and tea presented no clinically significant color alterations. It was concluded that disinfection in 1% sodium hypochlorite and peracetic acid altered the properties of roughness and color of the evaluated resins, and among the beverages, wine and grape juice were those that produced the greatest color alteration.
186

Verificação da existência de porosidade interna em duas resinas acrílicas termopolimerizáveis com diferentes volumes e métodos de processamento / Determination of internal porosity in two acrylic resins with different volumes and processing methods

Lessa, Cirley Maria de Lima 30 July 2010 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2016-09-21T18:30:35Z No. of bitstreams: 1 cirleymariadelimalessa.pdf: 6441265 bytes, checksum: 7a0229d5c35b96f2feef907ffa83d747 (MD5) / Approved for entry into archive by Diamantino Mayra (mayra.diamantino@ufjf.edu.br) on 2016-09-26T20:27:45Z (GMT) No. of bitstreams: 1 cirleymariadelimalessa.pdf: 6441265 bytes, checksum: 7a0229d5c35b96f2feef907ffa83d747 (MD5) / Made available in DSpace on 2016-09-26T20:27:45Z (GMT). No. of bitstreams: 1 cirleymariadelimalessa.pdf: 6441265 bytes, checksum: 7a0229d5c35b96f2feef907ffa83d747 (MD5) Previous issue date: 2010-07-30 / Este estudo utilizou de corpos de prova com diferentes volumes processados em água aquecida, com energia por micro-ondas e por polimerização termopneumohidráulica, com o objetivo de verificar visualmente a existência de porosidade interna nas resinas acrílicas termicamente ativadas das marcas Clássico® e Onda Cryl®. Para a confecção dos 60 corpos de prova, que foram divididos aleatoriamente em três grupos com diferentes volumes (n = 5), medindo respectivamente, 4 X 3cm, 3 X2cm, 1 X 2cm e 3 X 10 X 0,3cm, as resinas acrílicas foram manipuladas seguindo as recomendações do fabricante e posicionadas de forma manual nas muflas em sua fase plástica. Em seguida as muflas foram levadas à prensa hidráulica por um período de 08 horas e acondicionadas em um umidificador a 37ºC. Para o processamento por energia de micro-onda foi utilizado o ciclo de 40% da potência por 03 minutos, 0% da potência por 04 minutos e 90% da potência por 03 minutos. No convencional, os corpos de prova foram polimerizados em banho de água quente durante 09 horas a uma temperatura de 74ºC e no termopneumohidráulico, as muflas foram colocadas em uma termopolimerizadora à pressão de 20 libras até atingir a temperatura de 120ºC, seguido de um resfriamento até 90ºC, sendo novamente elevada até 120ºC por 40 minutos. Todas as muflas processadas nos três métodos foram mantidas em temperatura ambiente até o completo resfriamento. Após polimerização e demuflagem, os corpos de prova receberam acabamento e polimento. Para verificação da porosidade, três observadores utilizaram escores pré-determinados: “0” – ausência de poros; “1” – poros em quantidade mínima; “2” – poros em maior quantidade; “3” – poros ocupando grande parte do volume total e; “4” – poros na totalidade do volume. Os dados obtidos foram submetidos aos testes Kruskal-Wallis e Mann-Whitney com nível de significância de 5% (p ≤ 5). O escore “0” foi mais frequente com 37,8% seguido de escore “1” com 31,1%. Foi observada uma diferença estatisticamente significante entre os escores e os tamanhos dos corpos de prova (p = 0,023). A média percentual dos escores atribuídos aos corpos de prova de acordo com o método de polimerização atingiu 37,8%. Não foram observadas diferenças estatisticamente significantes entre os métodos de processamento, entretanto o valor de “p” atingiu 0,593. Pode-se concluir que os corpos de prova grandes apresentaram escore “1” e os médios, escore “3”; os corpos de prova pequenos e laminares apresentaram escore “1” e “0”, respectivamente. Os três métodos de polimerização utilizados foram equivalentes, não havendo diferença estatisticamente significante entre eles nas duas resinas acrílicas testadas. Independente do método de processamento, a porosidade interna foi diretamente proporcional ao volume dos corpos de prova. / This study used specimens with different volumes polymerized in heated water with microwave energy and thermopneumohydraulic curing, in order to visually verify the existence of internal porosity in the thermally activated acrylic resins Clássico® and Onda Cryl®. To make the 60 specimens, which were divided randomly into three groups with different volumes (n = 5), measuring respectively, 4 X 3cm, 3 X 2cm, 1 X 2cm and 3 X 10 X 0.3cm, acrylic resins were handled following the manufacturer's recommendations and positioned manually in flasks in its plastic phase. Then the flasks were brought to hydraulic press for a period of 08 hours and placed in a humidor at 37ºC. For processing by microwave energy, was used cycle 40% power for 03 minutes, 0% power for 04 minutes and 90% power for 03 minutes. In the conventional, the specimens were polymerized in heated water bath for 09 hours at a temperature of 74ºC and thermopneumohydraulic, flasks were placed in a thermal curing in pressure of 20 pounds to the temperature of 120ºC, followed by cooling to 90ºC, and again increased to 120ºC for 40 minutes. All flasks processed at the three methods were kept in room temperature until the complete cooling. After polymerization and unflanking, the specimens were finished and polished. To check the porosity, three observers used predetermined scores: "0" – no pore, "1" – pores in minimal amount, "2" – pores in greater quantity, "3" – pores occupying a large part of total and "4" – pores in the total volume. The data were subjected to Kruskal-Wallis and Mann-Whitney tests with a significance level of 5% (p ≤ 5). The score "0" was more frequent with 37.8% followed by the score "1" with 31.1%. A statistically significant difference between the scores and the sizes of the specimens (p = 0.023) was observed. The average percentage of the scores assigned to the specimens according to the method of polymerization reached 37.8%. There were no statistically significant differences between processing methods, however the “p” hit 0.593. It can be concluded that the specimens showed great score "1" and the average score "3", the samples were small and laminar score "1" and "0" respectively. The three polymerization methods used were similar, with no statistically significant difference between them in two acrylic resins tested. Regardless of the method of processing, the internal porosity was directly proportional to the volume of specimens.
187

EFEITO DE SOLUÇÕES HIGIENIZADORAS NA ESTABILIDADE DE COR E RUGOSIDADE DE RESINAS ACRÍLICAS PARA BASE DE DENTADURA / EFFECT OF CLEANING SOLUTIONS ON THE COLOR STABILITY AND ROUGHNESS OF DENTURE BASE ACRYLIC RESINS

Nora, Bárbara Dala 21 July 2016 (has links)
The aim of the study was to evaluate the effect of cleaning substances in color stability and roughness of acrylic resins to base definitive or provisional dentures polymerized by different methods. The factors evaluated were the type of acrylic resin (autopolymerized, heat-polymerized or microwave-polymerized), immersion media (alkaline peroxide, 0,5% sodium hypochlorite or artificial saliva as control) and time. Seventy-two disc-shaped specimens (8mmx2mm) were prepared (n = 8) and divided according to the experimental design. To determine color change (ΔE00) was used CIEDE2000 equation. The Ra parameter was used to determine the surface roughness of the samples. Baseline measurements were performed 24 hours after hydration (T0) and then the cps were subjected to 20 minutes daily immersions in media. New readings were performed in 30 (T1), 60 (T2) and 90 days (T3). Data were submitted to Analysis of Variance Test for Repeated Measures (Two-way ANOVA) followed by Tukey s Test (p <0,05). Significant effect was found over time, especially in color values (T2 and T3) and roughness for the autopolymerized resin (T3), which behaved worse. The solutions influenced color and roughness. Color stability and roughness were modified by means of immersion and varied depending on the type of polymerization, however the protocol of 20 minutes of immersion in cleaning solutions proved to be safe within the evaluated period for heat-polymerized and microwave-polymerized resin. / O objetivo do estudo foi avaliar o efeito substâncias de higienização na estabilidade de cor e na rugosidade de resinas acrílicas para base de dentadura definitiva ou provisória, polimerizadas por diferentes métodos. Os fatores avaliados foram o tipo de resina acrílica (autopolimerizável, termopolimerizável ou cura por micro-ondas), meios de imersão (peróxido alcalino, hipoclorito de sódio a 0,5% ou saliva artificial como controle) e tempo. Setenta e dois corpos de prova (cps) em forma de disco (8mmx2mm) foram confeccionados (n=8) e divididos conforme delineamento experimental. Para determinar alteração de cor (ΔE00) foi utilizada a equação CIEDE2000. O parâmetro de Ra foi empregado para determinar a rugosidade superficial média das amostras. As mensurações iniciais foram feitas 24h após a hidratação (T0) e a seguir os cps foram submetidos a imersões diárias de 20 minutos nos meios. Novas leituras foram realizadas nos tempos de 30 (T1),60 (T2) e 90 dias (T3). Os dados foram submetidos à Análise de Variância com dois fatores para Medidas Repetidas seguido de Teste de Tukey (p<0,05). Efeito significativo foi encontrado ao longo do tempo, principalmente nos valores de cor (T2 e T3) e rugosidade da resina autopolimerizável (T3), a qual se comportou de maneira inferior. Os meios influenciaram cor e rugosidade. Estabilidade de cor e rugosidade foram modificadas pelos meios de imersão e variaram conforme o tipo de polimerização, porém o protocolo de imersão em 20 minutos nas soluções higienizadoras mostrouse seguro dentro do período avaliado para as resinas termopolimerizável e cura por micro-ondas.
188

Síntese e caracterização de poli (metacrilato de metila-co-metacrilato de butila) para aplicação odontológica / Synthesis and characterization of poly (methyl methacrylate-co-butyl methacrylate) for dental application

Lucente, Ana Glaucia Bogalhos, 1984- 26 August 2018 (has links)
Orientador: Leila Peres / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Química / Made available in DSpace on 2018-08-26T22:00:36Z (GMT). No. of bitstreams: 1 Lucente_AnaGlauciaBogalhos_D.pdf: 2114033 bytes, checksum: ddc1d7f9bcfcce3f7ddfd258b22465d3 (MD5) Previous issue date: 2015 / Resumo: A falta de um material que viabilize a confecção de uma prótese dentária em um menor número de etapas, economizando tempo e facilitando a vida dos pacientes foi a maior motivação para o desenvolvimento desta tese que se baseia na patente BR n. PI 0602107-7 A: Conjuntos de arcos dentais pré-fabricados, flexíveis e com dentes ajustáveis obtida pelo grupo de pesquisa onde se insere este trabalho, em que se propõe o uso do arco dental flexível pré-fabricado na confecção da prótese, que poderá ser produzida em um menor tempo, com um menor custo. O material usado para o arco dental flexível pré-fabricado por energia de micro ondas, bem como para a prótese dental final deverá conter uma base polimérica que permitirá a flexibilidade inicial do arco, que após receber ajustes na posição dos dentes, adequados a cada paciente, será incorporado à prótese final, sendo o conjunto reticulado de forma simultânea. Para tanto, foi investigada a viabilidade do uso do copolímero de metacrilato de metila-n-metacrilato de butila (PMMA-co-PBMA), sintetizado via técnica de miniemulsão, como a matriz polimérica base para a confecção de arcos dentais pré-fabricados, flexíveis e com dentes ajustáveis e da prótese final. Na síntese do copolímero pretendido, foram estudadas as características dos iniciadores, surfactante, estabilizador e temperatura de reação sobre a distribuição volumétrica (Dv) e populacional (DSD) de tamanhos de partícula, conversão global, temperatura de transição vítrea (Tg), massa molar média ponderal (Mw), massa molar média numérica (Mn) e polidispersividade (Mw/Mn). Verificou-se a influência da solubilidade dos iniciadores em baixas temperaturas na conversão global, Dv e DSD, fator que não interfere em altas temperaturas. Além das análises de Tg, Mw e Mw/Mn dos copolímeros e homopolímeros obtidos por mecanismo de adição. Realizaram-se também análises de Ressonância Magnética Nuclear (RMN) e Espectroscopia no Infravermelho com Transformada de Fourrier (FT-IR) indicando que o copolímero foi formado na configuração alternada ou aleatória. A resina formulada a partir do copolímero sintetizado para uso no arco dental pré-fabricado foi caracterizado, a partir de ensaios de resistência à flexão, microdureza, módulo de elasticidade, coeficiente de Poisson, da Tg do material e monômero residual. Os resultados mostram um material compatível com resinas comerciais em relação à microdureza e módulo de elasticidade / Abstract: The lack of a material that enables the production of a dental prosthesis in fewer steps, saving time and making life easier for the patients was the major motivation for developing this thesis is based on the patent BR n. PI 0602107-7 A: Sets of prefabricated dental arches, flexible and adjustable teeth obtained by the research group which includes this work, it is proposed the use of prefabricated flexible dental arch in the making of the prosthesis, which can be produced in less time, with less cost. The material used for the flexible prefabricated dental arch by microwave energy and for the final dental prosthesis should contain a polymer base which will allow the initial flexibility of the arch, after receiving adjustments to the position of the teeth, adequate to each patient will be incorporated into the final prosthesis being crosslinked together simultaneously. Therefore, it was investigated the feasibility of using n-butyl methyl methacrylate-methacrylate copolymer (PMMA-co-PBMA) synthesized via miniemulsion technique as the base polymer matrix for the manufacture of prefabricated dental arches, flexible and adjustable teeth and the final prosthesis. In the synthesis of the desired copolymer characteristics of primers were studied, surfactant, stabilizer and reaction temperature on the size distribution (Dv) and population (DSD) particle size, overall conversion, glass transition temperature (Tg), mass-average molecular weight (Mw), number-average molecular weight (Mn) and polydispersity (Mw/Mn). It has been found to influence the solubility of the initiators at low temperatures in the overall conversion, Dv and DSD factor that does not interfere at high temperatures. In addition to the analyzes Tg, Mw and Mw / Mn of the copolymers and homopolymers obtained by adding mechanism. Nuclear Magnetic Resonance analysis (NMR) spectroscopy and Fourier transform infrared (FT-IR) were also performed indicating that the copolymer was formed in alternating or random configuration. The resin made from copolymer synthesized for use in prefabricated dental arch was characterized as bending strength tests, hardness, modulus of elasticity, Poisson's ratio, the Tg of the material and residual monomer. The results show a material similar to commercial resins with regard to hardness and modulus of elasticity / Doutorado / Ciencia e Tecnologia de Materiais / Doutora em Engenharia Quimica
189

Propriedades físicas da resina acrílica para coroas provisórias em função de diferentes técnicas de polimerização (rugosidade, porosidade, microdureza, sorção e solubilidade) / Physical properties of acrylic resin for provisional crowns under different curing techniques

Hiramatsu, Daniel Afonso 27 November 2009 (has links)
Foi realizada uma avaliação in vitro da influência de três variáveis sobre a rugosidade, porosidade, microdureza, sorção e solubilidade de uma resina acrílica para coroas provisórias: ambiente de polimerização (ar/água), temperatura e pressão de acordo com 4 técnicas de manipulação, diretas e indiretas. Os corpos de prova foram confeccionados utilizando a resina poli (metilmetacrilato) (PMMA) Dencorcor nº 66. A rugosidade de superfície (Ra) foi verificada por um rugosímetro/perfilômetro. Na análise da porosidade foi utilizado um método quantitativo de contagem dos poros por área delimitada utilizando um microscópio comparador. A análise da microdureza foi feita antes e depois da simulação do desafio ácido ocorrido na cavidade bucal. Para a análise de sorção e solubilidade os espécimes foram submetidos a ciclos de hidratação e ressecamento e através da comparação entre as pesagens iniciais e finais foi possível estabelecer os resultados. Os resultados de Rugosidade foram favoráveis às técnicas indiretas (grupos I e II) com médias de Ra=0,141m e 0,181m, respectivamente, seguidos pelas técnicas diretas (grupos III e IV) com Ra=0,373m e 0,908m. Os resultados de porosidade foram de 0,8 poros por área delimitada para o grupo I, seguido do grupo II com 0,9 poros; grupo III com 7,2 poros e grupo IV com 124 poros. Os resultados de microdureza para todos os grupos evidenciaram diminuição da dureza após a ciclagem ácida com valores que diminuíram de 14,12 para 13,03 no grupo I; de 14,06 para 12,93 no grupo II; de 13,73 para 12,71 no grupo III e de 13,47 para 12,65 no grupo IV. Os resultados de sorção foram de 1,807% para o grupo I; 1,817% para o grupo II; 2,068% para o grupo III e 2,227% para o grupo IV. E os resultados de solubilidade foram 0,036% para o grupo I; 0,054% para o grupo II; 0,184% para o grupo III e 0,212% para o grupo IV. Os maiores valores de rugosidade e porosidade foram alcançados pelos corpos-de-prova confeccionados pelas técnicas diretas e os menores valores se deram nos corpos-de-prova confeccionados segundo as técnicas indiretas e pela técnica do pincel. O desafio ácido reduziu a dureza da resina acrílica, porém não houve diferença nos testes de dureza entre os diferentes grupos. Os espécimes confeccionados pelas técnicas indiretas apresentaram menor sorção e solubilidade quando comparadas às técnicas diretas. Portanto, as técnicas indiretas de confecção de coroas provisórias devem ser preferidas às técnicas diretas. / An in vitro evaluation of the influence of three variables (polymerization medium (air/water), temperature and pressure) on roughness, porosity, microhardness, sorption and solubility of an acrylic resin for provisional crowns was conducted according to 4 techniques (direct and indirect). The samples were prepared using a poly (methylmethacrylate) (PMMA) resin Dencor color No 66. The surface roughness (Ra) was evaluated with a perfilometer. Porosity was analyzed according a quantitative method of counting number of pores per area by using a comparator microscope. Microhardness readings were made before and after acid challenge simulation as in the oral cavity. For sorption and solubility analysis, specimens were subjected to successive cycles of dampening and dehydration to make comparisons of the initial and final weights. Roughness results were lower for indirect techniques (groups I and II) with averages of Ra = 0.141m and 0.181m, respectively, followed by direct techniques (groups III and IV) with Ra = 0.373m and 0.908m. Porosity results were 0.8 pores per area for the group I, 0.9 pores for group II, 7.2 pores for group III and 124 pores for group IV. All groups showed a decrease in hardness after acid cycling with values that ranged from 14.12 to 13.03 in group I, 14.06 to 12.93 in group II, 13.73 to 12.71 in group III, and 13.47 to 12.65 in group IV. Sorption results were 1.807% in group I, 1.817% in group II, 2.068% in group III, and 2.227% in group IV. Solubility results were 0.036% in group I, 0.054% in group II, 0.184% in group III and 0.212% in group IV. Higher values of roughness and porosity were obtained by specimens made by direct technique and lower values were achieved with specimens made by indirect technique and brush technique. The acid challenge statistically decreased hardness of the acrylic resin, but there was no statistical difference among different groups. The specimens prepared by indirect techniques showed lower sorption and solubility when compared to direct techniques. The indirect techniques for making provisional crowns should be preferred compared to direct techniques.
190

Mechanical Properties Of Provisional Restorative Materials

Shimizu Oliva, Graciela, 1976- January 2010 (has links)
Indiana University-Purdue University Indianapolis (IUPUI) / A provisional restoration must fulfill biologic, mechanical, and esthetic requirements. These prostheses should provide comfort, pulp protection, positional stability, occlusal function, hygiene access, esthetics, strength and retention. Methyl-methacrylate acrylic has assumed many appli¬cations in the field of restorative dentistry. However, the material still has deficiencies, such as polymerization shrinkage, pulpal damage associated with exothermic polymerization and susceptibility to fracture. Bis-GMA composites, Bis-acryl composites and visible light-cured urethane dimethacrylate resins have been developed to address these issues. The purpose of this study was to compare the mechanical properties of provisional restorations made from composite resins (Protemp Plus, Luxatemp Solar, Radica, Protemp Crown) to those made of the traditional methacrylate resins (Jet, Snap, High Impact). Six groups of samples, two groups from methacrylate and four groups from composite based materials, were fabricated. Samples from each group were evaluated for microhardness (n=10), flexural strength and flexural modulus (n=20) according to ISO 4049, and fracture toughness (n=20) according to ISO 13586. From each of the six groups, ten samples were tested for flexural strength, flexural modulus and fracture toughness and 5 samples were tested for microhardness. These tests were done after storing at 37°C in a distilled water solution for 7 days followed by thermal cycling (2500 cycles, 5-55°C, 45 s. dwell). Identical sets of samples from each group were used as controls; these were tested after storing for 24 hours in dry conditions. The results were analyzed by two-way ANOVA with material type and aging conditions as the two main variables. Significance level was set at p=0.05. For flexural strength and flexural modules, the higher values were obtained for Radica. Protemp plus (7 days) and Radica (24h) had the highest fracture toughness value. Protemp crown showed the highest surface hardness. The mechanical properties of composite resin were superior.

Page generated in 0.0738 seconds