• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 13
  • 8
  • Tagged with
  • 21
  • 21
  • 4
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

[pt] ANÁLISE DA CONFIABILIDADE METROLÓGICA NA DETERMINAÇÃO DE CLOROFILA A EM AMOSTRAS DE ÁGUAS MARINHAS POR ESPECTROFOTOMETRIA

SIMONE PINTO PAIVA 04 April 2002 (has links)
[pt] O conhecimento da concentração de clorofila a e dos seus produtos de degradação em águas marinhas tem uma grande importância nos estudos ambientais. A utilização da técnica espectrofotométrica para esta finalidade envolve uma série de detalhes e considerações que podem afetar significativamente a confiabilidade metrológica dos resultados obtidos. Com o objetivo de minimizar as fontes de erro associadas à quantificação de clorofila a, foi feita uma avaliação minuciosa dos procedimentos de coleta, filtração, extração e análise das amostras realizados pelo Laboratório de Hidrobiologia da UFRJ. Uma redução na variabilidade dos resultados obtidos para amostras coletadas na praia da Urca foi evidenciada após as ações corretivas tomadas e a incerteza total foi calculada levando-se em conta a repetitividade do método. O espectrofotômetro do Laboratório foi devidamente validado e os valores obtidos para os limites de detecção (LDI e LDE) apresentaram-se satisfatórios quando comparados com os valores apresentados no método EPA 446.0 (Arar, 1997). O Laboratório demonstrou estar capacitado para garantir a confiabilidade dos resultados das análises de clorofila a, embora ainda tenha melhorias significativas para fazer no seu Sistema da Qualidade.
2

Evaluación de la deionización capacitiva de NaCl acuoso empleando un electrodo de carbón activado modificado con hexafluorofosfatro de 1-butil-3-metilimidazolio

Otsuka Salinas, Kenjo 04 September 2018 (has links)
En el presente trabajo de tesis, se presenta la síntesis, caracterización y aplicación de un electrodo de carbón activado y carbón activado modificado con el líquido iónico hexafluorofosfato de 1-butil-3-metilimidazolio en la remoción de cloruro de sodio mediante el proceso de deionización capacitiva (CDI) en soluciones acuosas salinas preparadas de 200, 500 y 1000 ppm y aplicando potenciales de 0,8; 1,0 y 1,2 V. El desarrollo de la tecnología de deionización capacitiva (CDI) para la desalinización de soluciones electrolíticas es un área bastante prometedora, registrándose hasta la fecha múltiples trabajos a escala de laboratorio e industrial. El proceso de deionización capacitiva (CDI) depende directamente de la capacitancia eléctrica de los materiales empleado como electrodos, la humectabilidad de estos, así como el potencial de trabajo aplicado entre los electrodos. Los materiales carbonosos al ser modificados con líquido iónico presentan un incremento de la capacitancia eléctrica, gran estabilidad electroquímica, así como una mejora de la humectabilidad. Ante esto, surge la siguiente interrogante: ¿será posible desarrollar un electrodo que contribuya a la mejora de la remoción de cloruro de sodio en el campo de la deionización capacitiva (CDI)?. Mediante voltametría cíclica se calcula la capacitancia eléctrica del carbón activado modificado y carbón activado; siendo 58,40 F/g y 44,20 F/g, respectivamente. Mediante la medición del ángulo de contacto se obtiene una mejora de la humectabilidad de 112,00° para el electrodo sin modificar a 61,90° para el electrodo modificado. Finalmente, se logra determinar que a una concentración salina de 1240 ppm y un potencial de 1,0 V se obtiene la mayor capacidad de remoción de 13,79 mg/g. / In the present thesis is presented the synthesis, characterization and application of an activated carbon electrode and activated carbon modified with ionic liquid 1-butyl-3- methylimidazolium hexafluorophosphate for the removal of sodium chloride in prepared aqueous saline solutions of 200, 500 and 1000 ppm and applying potentials of 0,8; 1,0 and 1,2 V by means of capacitive deionization process (CDI). The development of capacitive deionization (CDI) technology for the desalination of electrolytic solutions is a quite promising field, with multiple laboratory and industrial scale work being recorded to date. The capacitive deionization process (CDI) directly depends on the electrical capacitance of the materials used as electrodes, wettability, as well as the applied work potential between the electrodes. The carbonaceous materials modified with ionic liquid exhibit an increase in electrical capacitance, great electrochemical stability, as well as an improvement in wettability. Given this, the following question arises: will it be possible to develop an electrode that contributes to the improvement of the removal of sodium chloride in the field of capacitive deionization (CDI)? Through cyclic voltammetry technique, the electrical capacitance of modified activated carbon and activated carbon is calculated as 58,40 F/g and 44,20 F/g, respectively. By measuring the contact angle, an improvement in wettability is obtained from 112,00° for the unmodified electrode to 61,90° for the modified electrode. Finally, it is determined that the highest removal capacity of 13,79 mg/g is obtained at a saline concentration of 1240 ppm and a working potential of 1,0 V. / Tesis
3

Diseño, Construcción y Caracterización de un Destilador Solar Tubular para Desalinizar Agua de Mar

Mamani Flores, Efracio 14 October 2013 (has links)
El Destilador Solar Tubular (DST) fue diseñado y evaluado en el Centro de Energías Renovables de Tacna (CERT) de la UNJBG, Tacna, PERÚ. El trabajo se ejecutó a una escala piloto, con el fin de investigar el comportamiento y características del destilador y del agua destilada, respectivamente, bajo condiciones de irradiancia solar global de la ciudad de Tacna. Se empleó agua de mar para evaluar en el DST, se realizaron mediciones del volumen de agua destilada, temperaturas, irradiancia solar global y calidad de agua destilada, antes y después de la evaluación. El destilador solar tubular (DST) tiene una eficiencia de 47% en términos de procesamiento de agua destilada.
4

Análisis de la calidad de agua de mar y su relación con la infraestructura asociada a la actividad minera en la región de Antofagasta, entre los años 1990-2015

Monsalve Tapia, Rafaella January 2018 (has links)
Tesis para optar al Grado de Magíster en Geografía / Esta tesis, se desarrolló dentro del “Fondecyt Regular N° 1160848” llamado “¿Regiones Commodity? examinando las transformaciones territoriales de 40 años del modelo exportador. Comparando las experiencias de las regiones de Antofagasta (minería) y Los Lagos (salmonicultura)” y buscó conocer la relación de la calidad de agua de mar con la infraestructura asociada a la actividad minera en la región de Antofagasta, entre los años 1990-2015 Se desarrolla a partir de metodologías en Teledetección para el análisis de la calidad del agua de mar, la descripción de los proyectos ingresados al Servicio de Evaluación Ambiental correspondiente a centrales termoeléctricas y plantas desaladoras localizadas en las bahías de Algodonales, Mejillones, Antofagasta y Taltal y la producción minera en la región de Antofagasta para el periodo en estudio. El estudio refleja la diferencia en la calidad del agua de mar entre aquellas bahías que desarrollan actividades económicas tradicionales, como es el caso de bahía de Taltal, en comparación con la bahía de Mejillones que está sujeta a grandes tensiones debido a la intensa descarga de residuos líquidos al mar, proveniente de infraestructuras que nutren de materia prima a la minería en energía (centrales termoeléctricas) y agua (plantas desaladoras).
5

Uso da valorização eletrotérmica para a introdução de amostras no ICP-MS /

Pozebon, Dirce January 1998 (has links)
Tese (Doutorado) - Universidade Federal de Santa Catarina, Centro de Ciências Físicas e Matemáticas. / Made available in DSpace on 2012-10-17T04:43:11Z (GMT). No. of bitstreams: 0Bitstream added on 2016-01-08T23:34:32Z : No. of bitstreams: 1 144934.pdf: 32563715 bytes, checksum: 3564897cb195e86f17a01dcda83cc6f3 (MD5)
6

Detecção e quantificação de patógenos entéricos virais em amostras de água do mar

Moresco, Vanessa 25 October 2012 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Programa de Pós-Graduação em Biotecnologia, Florianópolis, 2011 / Made available in DSpace on 2012-10-25T19:49:50Z (GMT). No. of bitstreams: 1 289322.pdf: 1352290 bytes, checksum: 60582a492810471a9e9e523e508c5f7a (MD5) / A preocupação com a contaminação do ambiente aquático e, consequentemente, dos recursos hídricos, têm crescido devido a uma possível escassez da água potável no planeta. A contaminação das águas costeiras por vírus entéricos é causada pelo despejo de resíduos de origem fecal, afetando as águas utilizadas em atividades de recreação, pesca e no cultivo de moluscos bivalves, sendo responsável pela maioria dos surtos de gastroenterites que ocorrem no mundo. Indicadores bacterianos de contaminação fecal como os coliformes fecais, têm sido utilizados para o controle da qualidade das águas, porém já é estabelecido em todo o mundo que esta contaminação não está correlacionada com a presença de vírus entéricos. O desenvolvimento de novos métodos de concentração e detecção de vírus entéricos é uma alternativa para o controle da contaminação destas águas a fim de assegurar a qualidade de uso das mesmas. Os objetivos deste estudo foram: 1) Padronizar a metodologia de floculação utilizando leite desnatado acidificado na concentração de vírus em amostras de água do mar natural e artificial semeadas com quantidades conhecidas de adenovírus do sorotipo 2 (HAdV2). Comparar os resultados obtidos na recuperação viral com a metodologia já padronizada de filtração em membrana eletronegativa e reconcentração em Centriprep; 2) Aplicar metodologia padronizada na concentração e detecção de adenovírus humanos, poliomavírus cepa JC, vírus da hepatite A (HAV) e norovírus humano (HuNoV genogrupos GI e GII) em amostras de água do mar de 11 praias ao redor da Ilha de Santa Catarina, Florianópolis, Brasil durante um ano (Agosto de 2009 a Julho de 2010). 3) Analisar a presença de coliformes fecais (E. coli) e avaliar parâmetros físico-químicos, temperatura, pH, salinidade e oxigênio dissolvido. Para as detecções virais, o material genético das amostras foi extraído e diluído 1:10 para a redução de inibidores das reações enzimáticas. Nested-PCR qualitativo foi usado na detecção de HAdV e para a realização do sequenciamento. A detecção e quantificação de todos os vírus pesquisados foi realizada por PCR em tempo real. Os resultados da recuperação viral quando a metodologia de floculação foi empregada foram de 14% e 13,6% e no método de filtração, foram de 2,8% e 21% para as amostras de água do mar natural e artificial respectivamente. Das 132 amostras de campo analisadas, 16% foram positivas nas reações de nested-PCR para HAdV. Nas análises de PCR em tempo real, o vírus mais prevalente foi o HAdV, com 55% das amostras positivas, com intervalos de detecção de 8,40 x 103 a 1,9 x 107 CG/ L, seguido pelo HAV, com 51,5% de positividade, variando de 1,60 x 101 a 2,30 x 103 CG/ L. Para o JCPyV, 3% das amostras foram positivas, com intervalos de 1,90 x 104 a 1,70 x 105 CG/ L e para o NoV 7,5% e 4,5% das amostras foram positivas, com intervalos entre 2,41 x 103 a 5,14 x 106 e 3,73 x 104 a 2,10 x 106 CG/ L respectivamente para o GI e GII. As médias obtidas para os valores de coliformes fecais detectados foram de 8,0 a 1,325 UFC/100 mL em todos os pontos analisados. Somente dois dos pontos analisados não ultrapassaram o tolerável (Joaquina e Mole). Os demais pontos tiveram valores acima do permitido em algum mês do período analisado, destacando-se a Beira-Mar Norte com os valores mais elevados. As análises físico-químicas demonstraram valores concordantes com os previstos na legislação. O sequenciamento das amostras positivas para o HAdV demonstraram prevalência do adenovírus humano respiratório sorotipo 2. Os resultados obtidos evidenciam o destaque da contaminação viral nas amostras de água do mar e confirmam a não correlação da presença destes em relação à contaminação bacteriana. Este é o primeiro trabalho que avalia as condições das praias a redor da Ilha de Santa Catarina de forma mais abrangente, destacando diferentes tipos de contaminação. / The concern about aquatic environment contamination and consequently water resources is increasing mainly due to the warning about potable water scarcity in our planet. The contamination of coastal waters by enteric viruses is caused by discharge of residues of fecal origin, affecting waters used for recreational activities, fishing and shellfish growing, being responsible for most outbreaks of gastroenteritis occurring in the world. Bacterial indicators such as fecal coliforms have been used as parameters of water quality, however it has been clearly established worldwide that bacterial contamination show no relationship with the presence of human enteric viruses. The development of new methods of water concentration for enteric viruses detection is an alternative to monitor the contamination of these waters in order to ensure its quality.The objectives of this study were: 1) Standardize the methodology of flocculation using acidified skimmed milk for viral concentration in natural and artificial seawater samples previously spiked with known amounts of human adenoviruses serotype 2 (HAdV2). Results obtained with viral recovery were compared with the standardized methodology of water filtration in electronegative membrane and reconcentration by Centriprep#; 2) Apply standardized methodology in the concentration and detection of HAdV, poliomavirus (JCPyV), hepatitis A vírus (HAV) and noroviruses (HuNoV GI and GII) in seawater samples harvested in 11 different beaches in Santa Catarina Island, Florianópolis, Brazil in a period of one year (August 2009 to July 2010). Were also measured the presence of fecal coliform (E. coli) and physical-chemical parameters such as temperature, pH, salinity and dissolved oxygen. To reduce the presence of inhibitors of PCR reactions, a tenfold dilution of DNA/RNA of each sample was used. Nested-PCR was used for qualitative detection of HAdV and for conducting sequencing analysis. The detection and quantification of all the viruses evaluated was performed by real time PCR. The results of viral recovery by the standardized method of flocculation were 14% and 13.6% and for the filtration method, were 2.8% and 21% for samples of natural and artificial seawater respectively. From 132 field samples analyzed, 16% of these were positive for HAdV in the nested-PCR assay. In the analysis of real-time PCR, the most prevalent virus was HAdV, with 55% of positive samples with intervals of detection of 8.40 x 103 to 1.90 x 107 GC/ L, followed by HAV, with 51,5% of positivity, ranging from 2.30 x 101 to 1.60 x 103 GC/ L. For JCPyV, 3% of samples were positive, with ranges between 1.90 x 104 to 1.70 x 105 GC/ L and for NoV 7.5% and 4.5% of samples were positive, with intervals between 2.41 x 103 to 5.14 x 106 and 3.73 x 104 to 2.10 x 106 GC/ L respectively for GI and GII. The mean values of fecal coliforms detected were from 8.0 to 1.325 CFU/100 mL at all sites analyzed. Only two sites analyzed did not exceed the allowed by current legislation (Joaquina and Mole). The other sites showed, sometimes, values above the allowed during the period analyzed, with emphasis for Beira-Mar Norte site presenting the highest values. The physical-chemical analysis demonstrated values consistent with those recommended by legislation. The sequencing analysis of the samples positive for HAdV in qualitative PCR showed prevalence of human adenovirus respiratory serotype 2. The results show the highlight of viral contamination in the seawater samples and confirm the lack of correlation of their presence in relation to the bacterial contamination. This is the first study evaluating the conditions of the beaches around the Santa Catarina Island, highlighting different types of contamination.
7

Efeito do distanciamento ao mar da contaminação do concreto por cloretos

Vitali, Maria Rosane Vilpert January 2013 (has links)
Dissertação ( mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico, Programa de Pós-Graduação em Engenharia Civil, Florianópolis, 2013. / Made available in DSpace on 2014-08-06T17:38:29Z (GMT). No. of bitstreams: 1 322301.pdf: 3350698 bytes, checksum: 01081c55ab6edd129e10f68f1443de87 (MD5) Previous issue date: 2013 / As estruturas de concreto armado, quando inseridas em zonas de atmosfera marinha, são fortemente atacadas por agentes agressivos, sendo os cloretos os causadores dos maiores danos, provocando a corrosão das armaduras e afetando de forma significativa a vida útil da estrutura de concreto. Um dos principais parâmetros analisados na concepção dos projetos estruturais é a definição da classe de agressividade ambiental. A NBR 6118 (2007) define quatro classes de agressividade ambiental, sendo o ambiente marinho classificado como forte agressividade e proporcionando grande risco de deterioração à estrutura. A dificuldade atual dos projetistas de estruturas de concreto é justamente a limitação da extensão deste ambiente agressivo, motivo pelo qual alguns estudos já foram realizados no Brasil. A agressividade ambiental tem comportamento diferente em cada região e, por este motivo, desenvolveu-se esta pesquisa, para estudar a deposição de cloretos na região de São Francisco do Sul obtida através do aparato de vela úmida, método proposto pela NBR 6211 (2001). Paralelamente, prismas de concreto foram expostos juntamente aos aparatos de vela úmida, a fim de analisar o comportamento do ingresso de cloretos no concreto nas diferentes distâncias em relação ao mar. Sendo assim, o intuito deste estudo foi de propor uma segmentação para a atmosfera marinha na região de São Francisco do Sul, adotando-se como parâmetro, os limites da deposição de cloretos proposto por Meira (2004). Os resultados desta pesquisa mostraram uma distância de 1100 metros afastados do mar, a qual se estende a zona de atmosfera marinha e sendo este o limite entre as classes de agressividade II e III, definidas na NBR 6118 (2007). <br> / Abstract : The reinforced concrete structures, when inserted in areas with marine atmosphere, are strongly attacked by aggressive agents, being chlorides the main cause of the biggest damages, causing reinforcement corrosion and affecting significantly the useful life of the reinforced structure. One of the main parameters analyzed in the structure project conception is the definition of the environmental aggressiveness. The NBR 6118 (2007) defines four classes of environmental aggressiveness, being the marine environment classified as strong aggressiveness and providing great risk of deterioration to the structure. The current difficulty of the designers of concrete structures is precisely the limitation of the extension of this aggressive environment, reason why some studies have already been realized in Brazil. The environmental aggressiveness has different behavior in each region and, for this reason, this research has been developed, to study the deposition of chlorides in the São Francisco do Sul region obtained by wet candle apparatus, a method proposed by the NBR 6211 (2001). At the same time, concrete prisms were exposed along the wet candle apparatus, in order to analyze the behavior of the ingress of chlorides in the concrete in different distances in relation to the sea. Thus, the aim of this study was to propose segmentation to the marine atmosphere in the São Francisco do Sul region, adopting as a parameter, the limits of deposition of chlorides proposed by Meira (2004). The results of this research showed a distance of 1100 away from the sea, in which the marine atmosphere extends and being this the limit between the classes of aggressiveness II and III, defined by the NBR 6118 (2007).
8

Determinação de íons de metais traço (Cu²+, Pb²+ e Zn²+) por voltametria de redissolução em água do mar da baía norte da Grande Florianópolis

Claudino, Alessandro January 2003 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências Físicas e Matemáticas. Programa de Pós-Graduação em Química. / Made available in DSpace on 2012-10-20T14:12:25Z (GMT). No. of bitstreams: 1 199743.pdf: 3269053 bytes, checksum: d5192159aad9519e63f5559a1d276b1d (MD5) / O trabalho aqui apresentado teve o objetivo de analisar a qualidade da água superficial do mar, na região costeira da Baía Norte de Florianópolis, no período da baixa e alta temporada de verão, quando a população é acrescida de um grande número de turistas. Analisar o teor de íons de metais como o zinco, o cobre e o chumbo em águas costeiras, que possuem relação com toxicidade é de grande importância, pois atividades de maricultura são desenvolvidas nas proximidades. Utilizamos para a determinação do zinco e chumbo a técnica de Voltametria de Redissolução Anódica (ASV) e para o cobre a Voltametria de Redissolução Catódica (ACSV), em amostras de oito pontos da água do mar da Baía Norte de Florianópolis. Esta técnica foi escolhida pela alta sensibilidade, seletividade, simplicidade e custo relativamente baixo. A análise do branco de campo mostrou que os procedimentos de coleta, filtração, conservação e irradiação das amostras, mantiveram um índice de contaminação controlado. As amostras tiveram sua matéria orgânica destruída por radiação ultravioleta e foram filtradas antes das análises. Como eletrodo de trabalho foi utilizado o Eletrodo de Mercúrio de Gota Pendente (HMDE) e os parâmetros eletroquímicos utilizados foram: velocidade de varredura de 20 mV S-1, altura de pulso diferencial de 50 mV, largura de 50 ms e tempo de equilíbrio de 10 s para todas as análises. De acordo com os resultados, a concentração de chumbo variou de 0,33 a 8 nmol L-1, o zinco de 1,3 a 18 nmol L-1 e o cobre de 19 a 54 nmol L-1. Estes valores são relativamente baixos se comparados com outras regiões costeiras poluídas. De maneira geral as análises dos metais realizadas após a temperada de veraneio, (segunda coleta) apresentaram um aumento das respectivas concentrações, porém nas duas coletas os valores permaneceram abaixo do fixado pela resolução número 20 do CONAMA.
9

Aclimação e desempenho de tilápias (Oreochromis sp.) em sistema de recirculação de água do mar

Ostini, Sérgio [UNESP] 22 February 2002 (has links) (PDF)
Made available in DSpace on 2016-09-27T13:40:13Z (GMT). No. of bitstreams: 0 Previous issue date: 2002-02-22. Added 1 bitstream(s) on 2016-09-27T13:45:34Z : No. of bitstreams: 1 000164745.pdf: 509292 bytes, checksum: 43f209069b1d0ff2b1ec930d2f9a1425 (MD5) / Alevinos de tilápia vermelha foram transferidos diretamente da água doce (0‰) para água do mar (35‰), e também submetidos a dois diferentes sistemas gradativos de aclimação: aumento gradual de salinidade em 5‰ a cada dia e, aumentos de 5‰ a cada dois dias. O estudo foi conduzido no Setor de Carcinicultura do Centro de Aqüicultura da Universidade Estadual Paulista (CAUNESP), Jaboticabal, SP. Três diferentes tamanhos de alevinos de tilápia vermelha foram testados: tratamento 1 - animais com 18,50 ± 1,2 mm; tratamento 2 - 49,33 ± 4,45 mm; tratamento 3 - 71,97 ± 5,7 mm respectivamente. Grupos de 10 animais (n = 3) de cada classe de tamanho foram transferidos diretamente da água doce para água do mar em aquários de 10 litros, aerados, e mantidos a 26ºC e com salinidade de 35‰, A mortalidade foi avaliada em intervalos de 15 minutos. Para aclimação gradativa, 25 animais por parcela (n = 3) foram mantidos em tanques cilíndrico-cônicos de 100 L equipados com filtro mecânico de 40 L com substrato de conchas marinhas. Os peixes foram alimentados duas vezes ao dia, sendo a temperatura, salinidade e mortalidade avaliadas diariamente. Os experimentos tiveram duração de 20 dias cada, e 20% dos indivíduos sobreviventes foram submetidos à biometria. Os dados foram analisados segundo delineamento fatorial 3 x 2. Os resultados demonstraram não haver sobrevivência da tilápia vermelha, quando transferida diretamente da água doce para a água do mar, para todos os tamanhos estudados. Os sistemas de aclimação demonstram a viabilidade de aclimação gradativa de alevinos de tilápia vermelha em todos os tamanhos testados, porém, a maior taxa de sobrevivência foi obtida com alevinos com comprimento padrão médio ³ a 49,3 mm e aumento de salinidade de 5‰.dia- 1, Os animais apresentaram melhores condições corporais quando aclimados mais lentamente (5‰ 2 dias-1) / Red tilapia fingerlings were either directly transferred from freshwater to sea water (35‰) and also submitted to two different systems of gradual acclimation: daily increasing of 5‰ and the same gradual increment every two days. The study was set up at the Freshwater Prawn Laboratory, classes Aquaculture Center of the UNESP, Jaboticabal, SP. Three different size of red tilapia fingerlings were used: Trial 1 - 18.5 ± 1.2 mm, Trial 2 - 49.33 ± 4.45mm and Trial 3 - 71.9 ± 5.7 mm, respectively. Groups of 10 animals (n = 3) of each class were directly transferred to sea water in 10 L aquarium and maintained at 26oC, 35‰ salinity, and mortality were recorded every 15 minutes. For the gradual acclimation, 25 fish per parcel (n = 3) of each treatment were stocked in 100 L, conic-cylindrical tanks equipped with mechanical filter (40 L) made out of marine shell substrate. Fish were fed twice a day and water salinity and temperature and mortality were recorded every day. The experiment lasted for 20 days, 20% of the remained fish were weighed and data were analyzed through a 3 x 2 factorial. Results show that the tolerance of red tilapia to direct transfer to sea water increases with size until a certain extent, and that viability of a gradual acclimation to marine water as satisfactory for all tested class sizes but better survival rates were obtained with fingerlings measuring 49.3 mm total length, with a daily increase in salinity of 5‰. Better condition factor was presented by animals acclimated with 5‰ increase every two days
10

Diseño de un Destilador Solar de Mediana Escala

Peñailillo Benavente, Daniela Olivia January 2007 (has links)
No description available.

Page generated in 0.085 seconds