• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 487
  • 133
  • 51
  • 49
  • 21
  • 18
  • 14
  • 13
  • 11
  • 8
  • 5
  • 3
  • 3
  • 3
  • 2
  • Tagged with
  • 987
  • 987
  • 235
  • 205
  • 205
  • 186
  • 130
  • 129
  • 111
  • 81
  • 77
  • 76
  • 76
  • 73
  • 71
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
341

Edmonton Indoor Air Quality Study (EIAQS): Determinants of Residential Benzene

Chui, Phyllis H. Y. Unknown Date
No description available.
342

Dynamic Behavior Of Water And Air Chemistry In Indoor Pool Facilities

Lester Ting Chung Lee (11495881) 22 November 2021 (has links)
<p>Swimming is the second most common form of recreational activity in the U.S. Swimming pool water and air quality should be maintained to allow swimmers, pool employees, and spectators to use the pool facility safely. One of the major concerns regarding the health of swimmers and other pool users is the formation of disinfection by-products (DBPs) in swimming pools. Previous research has shown that volatile DBPs can adversely affect the human respiratory system. DBPs are formed by reactions between chlorine and other compounds that are present in water, most of which are introduced by swimmers, including many that contain reduced nitrogen. Some of the DBPs formed in pools are volatile, and their transfer to the gas phase in pool facilities is promoted by mixing near the air/water interface, caused by swimming and pool features.</p> <p><a>Swimming pool water treatment processes can play significant roles in governing water and air quality.</a> Thus, it is reasonable to hypothesize that water and air quality in a swimming pool facility can be improved by renewing or enhancing one or more components of water treatment.</p> <p>The first phase of the study was designed to identify and quantify changes in water and air quality that are associated with changes in water treatment at a chlorinated indoor pool facility. Reductions of aqueous NCl<sub>3 </sub>concentration were observed following the use of secondary oxidizer with its activator. This inclusion also resulted in significant decreases in the concentrations of cyanogen chloride (CNCl) and dichloroacetonitrile (CNCHCl<sub>2</sub>) in pool water. The concentration of urea, a compound that is common in swimming pools and that functions as an important precursor to NCl<sub>3</sub> formation, as well as a marker compound for introduction of contaminants by swimmers, was also reduced after the addition of activator.</p> <p>The second phase of this study involved field measurements to characterize and quantify the dynamic behavior of indoor air quality (IAQ) in indoor swimming pool facilities, particularly as related to volatile compounds that are transferred from swimming pool water to air. Measurements of water and air quality were conducted before, during, and after periods of heavy use at several indoor pool facilities. The results of a series of measurements at different swimming pool facilities allowed for examination of the effects of swimmers on liquid-phase DBPs and gas-phase NCl<sub>3</sub>. Liquid-phase NCl<sub>3</sub> concentrations were observed to gradually increase during periods of high swimmer numbers (<i>e.g.</i>, swimming meets), while liquid-phase CHCl<sub>3</sub> concentration was nearly constant in the same period. Concentrations of urea displayed a steady increase each day during these periods of intensive use. In general, the highest urea concentrations were measured near the end of each swimming meet. </p> <p>Measurements of IAQ dynamics during phase 2 of the study demonstrated the effects of swimmers on the concentrations of gas-phase NCl<sub>3 </sub>and CO<sub>2</sub>, especially during swimming meets. The measured gas-phase NCl<sub>3</sub> concentration often exceeded the suggested upper limits of 300 µg/m<sup>3</sup> or 500 µg/m<sup>3 </sup>during swimming meets, especially during and immediately after warm-up periods, when the largest numbers of swimmers were in the pool. Peak gas-phase NCl<sub>3</sub> concentrations were observed when large numbers of swimmers were present in the pools; measured gas-phase concentrations were as high as 1400 µg/m<sup>3</sup>.<sup> </sup>Concentrations of gas-phase NCl<sub>3</sub> rarely reached above 300 µg/m<sup>3</sup> during regular hours of operation. Furthermore, the types of swimmers were shown to affect the transfer of volatile compounds, such as NCl<sub>3</sub>, from water to air<sub> </sub>in pool facilities. In general, adult competition swimmers promoted more rapid transfer of these compounds than youth competition swimmers or adult recreational swimmers. The measured gas-phase CO<sub>2</sub> concentration often exceeded 1000 ppm<sub>v</sub> during swimming meets, whereas the gas-phase CO<sub>2</sub> concentration during periods of non-use of the pool tended to be close to the background (ambient) CO<sub>2</sub> concentration or slightly more than 400 ppm<sub>v</sub>. This phenomenon was largely attributed to the activity of swimmers (mixing of water and respiratory activity) and the normal respiratory activity of spectators. </p> <p>IAQ models for gas-phase NCl<sub>3</sub> and CO<sub>2</sub> were developed to relate the characteristics of the indoor pool environment to measurements of IAQ dynamics. Several assumptions were made to develop these models. Specifically, pool water and indoor air were assumed to be well-mixed. The reactions that were responsible for the formation and decay of the target compounds were neglected. Two-film theory was used to simulate the net mass-transfer rate of volatile compounds from the liquid phase to the gas phase. Advective transport into and out of the air space of the pool were accounted for. The IAQ model was able to simulate the dynamic behavior of gas-phase NCl<sub>3</sub> during regular operating hours. Predictions of gas-phase NCl<sub>3</sub> dynamics were generally less accurate during periods of intensive pool use; however, the model did yield predictions of behavior that were qualitatively correct. Strengths of the model include that it accounts for the factors that are believed to have the greatest influence on IAQ dynamics and is simple to use. Model weaknesses include that the model did not account liquid-phase reactions that are responsible for formation and decay of the target compounds. The IAQ model for NCl<sub>3</sub> dynamics could still be a useful tool to form the basis for recommendations regarding the design and operation of indoor pool facilities so as to optimize IAQ.</p><p>Measurements of CO<sub>2</sub> dynamics indicated qualitatively similar dynamic behavior as NCl<sub>3</sub>. Because of this, it was hypothesized that CO<sub>2</sub> may represent a surrogate for NCl<sub>3</sub> for monitoring and control of IAQ dynamics. To examine this issue in more detail, a conceptually similar model of CO<sub>2 </sub>dynamics was developed and applied. The model was developed to allow for an assessment of the relative contributions of liquid®gas transfer and respiration by swimmers and spectators to CO<sub>2</sub> dynamics. The results of this modeling effort indicated that the similarity of CO<sub>2</sub> transfer behavior to NCl<sub>3</sub> may allow use of CO<sub>2</sub> as a surrogate during periods with few to no spectators in the pool; however, when large numbers of spectators are present, the behavior of CO<sub>2</sub> dynamics may not be representative of NCl<sub>3</sub> dynamics because of spectator respiration.</p><p></p> <br>
343

INDOOR AIR QUALITY AND ENVIRONMENTAL CONSULTING: MY INTERNSHIP EXPERIENCE AS AN AIR MONITOR FOR NOVA ENVIRONMENTAL, INC.

Hamilton, Julia, Hamilton 02 August 2018 (has links)
No description available.
344

Improving Building Energy Efficiency Through Implementation Of An Active Indoor Rhizospheric Microbe Air Processing System

West, Cortney January 2016 (has links)
Commercial energy use in Arizona is different from the rest of the United States because of their high demand for air conditioning. Nearly half of the energy used in commercial buildings goes to heating, cooling, and ventilation. In an attempt to reduce overall every use in buildings, looking at these categories led to an examination of ventilation in buildings, which is the main cause for high heating and cooling costs. Ventilation of fresh air is required in order to provide a safe, healthy environment, with acceptable indoor air quality. Indoor air quality and pollution has continuously come to light as a major health concern for building occupants. Chemicals used in manufacturing allow consumers to buy and expose themselves to toxic substances such as volatile organic compounds on a daily basis. With minimal regulations on indoor air, it is important to find ways to better filter and clean it. The traditional solution is ventilation, but more fresh air ventilation means more heating and cooling. This paper explores the research that has been done on plants and phytoremediation and the applicability to indoor air quality. With the proof that certain combinations and amounts of plants can filter the air of volatile organic compounds, systems are explored for indoor air filtration instead of mechanical ventilation. This type of system can greatly reduce heating and cooling costs in buildings due to the reduction of outdoor air being brought in and requiring conditioning. A system of this type is a feasible solution to indoor air quality and can lead to a significant reduction in energy use. The proposed AIRMAPS is a system that in certain quantities can reduce the need for fresh air ventilation by 25%, which in turn has shown through the validation by eQUEST, that the energy used for heating, cooling, and ventilation fans can also be reduced by approximately the same amount. The plants used are spider plant, dumb cane, English ivy, and golden pothos. The average formaldehyde removal by each of these plants is a low approximation of 75% per cubic meter. This paper also considers the growing materials used for the plants; activated carbon, potting soil mix, and grow-stones, as well as their formaldehyde removal capabilities.
345

Inlet and outlet shape design of natural circulation building ventilation systems

Swiegers, Jacobus Johannes 03 1900 (has links)
Thesis (MEng)--Stellenbosch University, 2015. / ENGLISH ABSTRACT: Increased awareness of environmental problems has awakened interest in renewable energy systems. Natural ventilation systems are especially of interest, as people spend most of their time indoors. Indoor air quality is an important consideration when human health and occupant comfort is to be maintained. This study focusses on determining the best inlet and outlet shape for a natural ventilation system from a chosen set of configurations. The inlet and outlet configurations were tested on a PDEC (Passive Downdraught Evaporative Cooling) shaft and solar chimney. The PDEC incorporated an evaporative cartridge made from cotton cloth. Independent models of the PDEC and solar chimney were built in a thermally controlled space where the configurations were tested at different wind speeds. The configurations were tested on a wet or dry PDEC shaft and on a hot or cold solar chimney. One-dimensional finite difference models, accounting for some two-dimensional effects in the evaporative cartridge, of the cartridge and solar chimney were developed. CFD (Computational Fluid Dynamics) models were further constructed in FLUENTr, simulating operating conditions for each inlet and outlet test. The CFD models were constructed to obtain numerical comparisons for the experimental data. The ability of the one-dimensional and CFD models to predict the performance of the PDEC and solar chimney were investigated. The results indicated that an inlet configuration called a TFI (Turbine Fan Inlet) performed the best at the tested wind speeds. The TFI was further able to significantly increase volumetric flow rate in the PDEC shaft for the dry evaporative cartridge tests. The outlet that performed best under the tests is a Windmaster Tornado Wind Turbine, or Whirlybird, which is a commercially available configuration. The one-dimensional models were not able to accurately predict conditions during start-up. The CFD models were highly accurate in predicting the experimental values. It is recommended that a two-dimensional theoretical model be developed to better predict start-up conditions. / AFRIKAANSE OPSOMMING: Verhoogde bewustheid van omgewings probleme het belangstelling in hernubare energie stelsels ontwaak. Natuurlike ventilasie stelsels is veral van belang, sedert mense die meeste van hul tyd binnenshuis spandeer. Binnenshuise lug kwaliteit is ’n belangrike oorweging wanneer menslike gesondheid en insittendes se gemak in stand gehou moet word. Hierdie studie fokus op die bepaling van die beste inlaat en uitlaat vorm van ’n gekose stel konfigurasies vir ’n natuurlike ventilasie-stelsel. Die inlaaten uitlaat-konfigurasies is op ’n PDEC (Passive Downdraught Evaporative Cooling) skag en sonkrag skoorsteen getoets. Die PDEC het ’n verdampings doek, gemaak van katoen, ingesluit. Onafhanklike modelle van die PDEC en sonkrag skoorsteen is in ’n termies-beheerde ruimte en die konfigurasies is by ’n onveranderende wind spoed getoets. Die konfigurasies is op ’n nat of droog PDEC skag en op ’n warm of koue son skoorsteen getoets. Een-dimensionele eindige verskil modelle, wat sommige twee-dimensionele effekte in ag neem in die verdampings doek, van die doek en sonkrag skoorsteen is ontwikkel. CFD (Computational Fluid Dynamics) modelle is verder gebou in FLUENTr, wat die werkstoestande vir elke inlaat en uitlaat toets simuleer. Die CFD modelle is ontwikkel om die eksperimentele data met numeriese waardes te vergelyk. Die vermoë van die een-dimensionele en CFD modelle om die verrigting van die PDEC en sonkrag skoorsteen te voorspel, is ondersoek. Die resultate dui daarop dat ’n inlaat opset genoem TFI (Turbine Fan Inlet) die beste vaar by die elke getoetsde wind spoed. Die TFI was verder in staat om die volumetriese vloeitempo in die PDEC skag aansienlik te verhoog vir die toetse met ’n droë verdamping doek. Die uitlaat wat die beste presteer het in die toetse is ’n Windmaster Tornado Wind Turbine, of Whirlybird, wat ’n kommersieel beskikbare konfigurasie is. Die een-dimensionele modelle was nie in staat om die toestande tydens die begin-fase akkuraat te voorspel nie. Die CFD modelle was hoogs akkuraat in die voorspelling van die eksperimentele waardes. Dit word aanbeveel dat ’n twee-dimensionele teoretiese model ontwikkel word om die toestande tydens begin-fase beter te voorspel.
346

Investigating the influence of vehicular traffic on a major trunk road on rural air quality

Obara, Paul Goodluck January 2012 (has links)
Traffic population in the UK has grown by 27% in 2002 and predicted to continue to an estimated 38% in 2016 and up to 60% by 2031. This means vehicular emissions from road transport may account for higher proportion of total emissions of pollutants resulting in air pollution with its attendant consequences. Although poor air quality concerns has often been linked to urban areas, many rural areas apparently have locations where air quality objectives may be threatened especially in the wake of increasing vehicular population. Thus, this elicits the necessity to investigate the relationship between vehicular emissions and air quality. This study investigated the influence of vehicular traffic on a major trunk road on rural air quality through continuous measurements of nitrogen dioxide, sulphur dioxide and hydrocarbon between June 2008 and April 2010 along a major trunk road in a catalogued rural environment in the UK. Collection and analysis of pollutants was by Dräger short-term tubes and Dräger passive diffusion tube techniques. Throughout the sampling period, concentrations of sulphur dioxide were not detected using the short-term tube technique but were detected by the passive diffusion tubes. The study found that variations in mean concentrations of the pollutants were synonymous with traffic frequency and were influenced by meteorological conditions especially wind speed, temperature and relative humidity. Results observed concentration decline trend with increasing distance and showed maximum concentrations during winter, mainly in areas of close proximity to anthropogenic source, and minimum in summer. Values between winter year 1 and winter year 2 monitoring campaigns showed significant difference (P<0.05 and R=0.91) as was in summer year 1 and year 2 (P<0.05 and R=0.94), spring year 1 and year 2 (P<0.05 and R=0.84) and autumn year 1 and year 2 (P<0.05 and R=0.79). When compared with the guidance limits, NO2 Page ii showed exceededance at roadside and 50 m, and at some sample sites, up to 100 m from the road. Conversely, SO2 did not show any exceedance but statistical analyses was mostly significant between concentrations and distance at p≤0.05, suggesting the variability of pollutants, as well as the influence of distance on their temporal and spatial distribution. Results also show that pollutants correlated very well with daily traffic population with strong positive r2 and R-values. Similarly, the study considered the application of hazel leave (Corylus avellana) and ryegrass (Lolium perenne) vegetation samples in monitoring rural air quality. Both samples were collected in different seasons and distances (5m, 50m, and 100m) from the A49 trunk road at four rural sites characterised with diverse traffic densities and anthropogenic activities. The aim was to determine the elemental content and trends within the samples and to investigate the influence of distance from the road, height from ground level, and sampling season on the elemental levels. The levels of Al, As, Ba, Ca, Si, Mg, S, Cd, Cr, Na, Ni, Sb, Se, Sn, Mo, Mn, C, K, P, Cl, Ti, Fe, Zn, and Pb were determined using X-ray fluorescence (XRF), inductively coupled plasma-mass spectrometer (ICP-MS), and Scanning Electron Microscopy-Energy Dispersive X-ray spectrometer (SEM-EDX). Results show that despite the traffic differentials between the sampling sites, the pollution level of heavy metals were generally low in all sampling site and concentrations of Cr, Cu, Ni, Pb, and Ti exhibited inverse relationship with distance, decreasing in levels with increasing distance from the trunk road. Although root uptake from the soil is a potential source of heavy metals, geochemistry research of the study area did not show any evidence that proves any major heavy metals deposit concerns in the soil. It is therefore possible that heavy metal emissions were deposited in a form that was not readily available for root uptake, thereby narrowing the presence of heavy metal pollutants to other potential Page iii sources. However, this study found high level of heavy metals at the roadside measurements in the order of Zn (0.703 ppm) > Ti (0.346 ppm) > Cr (0.111 ppm) > Cu (0.106 ppm) > Pb (0.026 ppm) > Ni (0.025 ppm). They were found in different magnitudes higher than their respective levels at 50 and 100 m from the trunk road and therefore tend to support traffic origin. Findings from this study show that heavy metals exhibited different degree of correlation between individual elements, ranging from very strong positive to weak, as well as negative correlations. Statistical analyses show that the elements predominantly exhibited statistically significant differences between elements and between distances from the road. Overall, findings from this study demonstrate that both vegetation species prove to be successfully useful in determining the pollution status and trends of traffic-related heavy metals.
347

Managing the health impacts of transport-related air pollution: a study of the diesel-to-petrol switchingpolicy in Hong Kong

Kwok, King-yu., 郭經裕. January 2000 (has links)
published_or_final_version / Urban Planning and Environmental Management / Doctoral / Doctor of Philosophy
348

Air quality and urban development

Wong, Yue-kwong, Michael., 黃宇光. January 1999 (has links)
published_or_final_version / Environmental Management / Master / Master of Science in Environmental Management
349

A critical review over Hong Kong indoor air quality policy on biological parameters

Chan, Yee-shan., 陳綺珊. January 2004 (has links)
published_or_final_version / Environmental Management / Master / Master of Science in Environmental Management
350

Air quality study inside and outside vehicular tunnels in Hong Kong

Lai, Kam-hung., 黎錦雄. January 1994 (has links)
published_or_final_version / Environmental Management / Master / Master of Science in Environmental Management

Page generated in 0.0545 seconds