• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 120
  • 3
  • 1
  • Tagged with
  • 125
  • 94
  • 48
  • 46
  • 35
  • 32
  • 32
  • 32
  • 31
  • 29
  • 28
  • 24
  • 24
  • 20
  • 20
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
121

"Contribuição da ressonância magnética na avaliação de doadores do lobo direito ao transplante hepático intervivos" / Contribuition of magnetic resonance in the evaluation of donors for right lobe living liver transplantation

Gisele Warmbrand 14 December 2004 (has links)
Este estudo teve, por finalidade, estabelecer o valor da ressonância magnética em 30 doadores potenciais do lobo direito do fígado, na determinação dos seguintes fatores: esteatose hepática; anatomia biliar; anatomias arterial hepática, venosas portal e hepática, e volume hepático lobar, comparando-os, respectivamente, com os achados anatomopatológicos da biópsia hepática, da colangiografia intraoperatória, da angiografia digital e/ou com os achados cirúrgicos, e com o peso real do enxerto. A RM subestimou a infiltração gordurosa hepática; permitiu identificar a anatomia biliar, com concordância em 83% dos casos; apresentou 100% de concordância na avaliação das anatomias arterial e venosas portal e hepática, e superestimou, em pequeno grau, o volume hepático lobar / The purpose of this study was to establish the value of the magnetic resonance in 30 potential donors for right lobe living liver transplantation. The main goal was to determine the following factors: steatosis; biliar anatomy; hepatic arterial anatomy; portal and hepatic venous anatomy, and lobar liver volume, comparing them to liver biopsy results, to intraoperative colangiography, to digital angiography and/or surgical findings, and to the real graft weight, respectively. The MR has underestimated liver steatosis; it has identified biliar anatomy with 83% of agreement; it has had 100% of agreement in the evaluation of arterial and portal and hepatic venous anatomy, and it has overestimated with small degree the lobar liver volume
122

Revascularização cirúrgica do miocárdio com utilização de enxerto de artéria radial esqueletizada ou com tecidos adjacentes: análise comparativa randomizada / Surgical revascularization of the myocardium with the use of grafts of the skeletonized radial artery or with surrounding tissues: random comparative analysis

Rômulo César Arnal Bonini 01 October 2007 (has links)
INTRODUÇÃO: A utilização de enxertos arteriais na revascularização cirúrgica do miocárdio já está bem estabelecida atualmente pelos cirurgiões cardiovasculares, e sua esqueletização tem apresentado algumas vantagens, a princípio com a artéria torácica interna esquerda. OBJETIVO: Com o objetivo de analisar esse método de dissecção na artéria radial, foram avaliados os desempenhos funcional e hemodinâmico bem como as características morfoanatômicas e histológicas dos enxertos aortocoronários de artéria radial, esqueletizados ou com tecidos adjacentes, na revascularização cirúrgica do miocárdio. MÉTODOS: Foram comparados 40 pacientes, distribuídos randomicamente em dois grupos. No grupo I foi utilizada artéria radial esqueletizada (20 pacientes) e no grupo II, artéria radial com tecidos adjacentes (20 pacientes), para os ramos marginais da artéria coronária esquerda. No total, 39 pacientes foram submetidos a cinecoronariografia e fluxometria com cateter-guia Doppler de 12 MHz (0,014 polegada, Flowire, Jometrics Inc.), no pós-operatório imediato. RESULTADOS: Os dois grupos apresentaram características demográficas semelhantes. As variáveis intra-operatórias principais da artéria radial também foram semelhantes, com comprimento de 17,1 cm no grupo I e de 16,3 cm no grupo II, e débito livre de 80,3 ml/min no grupo I e de 95,5 ml/min no grupo II. Não foram observadas diferenças morfoanatômicas e histológicas nos grupos comparados. Os diâmetros dos enxertos de artéria radial, calculados por meio de angiografia quantitativa no pós-operatório, foram semelhantes (2,66 mm no grupo I e 2,53 mm no grupo II), assim como as variáveis fluxométricas (fluxo sanguíneo de 54,9 ml/min no grupo I e de 44,28 ml/min no grupo II, e reserva de fluxo de 2,12 no grupo I e de 2 no grupo II). Por outro lado, a cinecoronariografia revelou presença de oclusão em um enxerto e estenose em cinco enxertos no grupo II, enquanto o grupo I apresentou estenose em apenas um enxerto de artéria radial (p = 0,091). CONCLUSÕES: Os enxertos aortocoronários de artéria radial tiveram bom desempenho funcional e hemodinâmico precoce. Não houve diferença entre os grupos quanto ao desempenho funcional e hemodinâmico precoce, e quanto às características morfoanatômicas e histológicas. / BACKGROUND: The use of artery grafts in the surgical revascularization of the myocardium is currently a well-established procedure by cardiovascular surgeons, and its skeletonization has posed some advantages, in principle, with the left internal thoracic artery. OBJECTIVE: With the purpose of analyzing this radial artery harvest method, the study evaluated the functional and hemodynamic early performance, as well as the morphological anatomic and histological features of the aortic coronary grafts of the radial artery, skeletonized or with surrounding tissues, in the surgical revascularization of the myocardium. METHODS: The study compared 40 patients, randomly distributed in two groups. In Group I, we employed a skeletonized radial artery (20 patients), and in Group II, the radial artery with surrounding tissues (20 patients), for the marginal branches of the left coronary artery. In total, 39 patients underwent cinecoronariography and fluxometry with a 12-MHz Doppler guide catheter (0.014 in., Flowire, Jometrics Inc.), in the immediate postoperative period. RESULTS: Both groups presented similar demographic features. The main intra-surgical variables of the radial artery were also similar, with an extension of 17.1 cm in Group I, and 16.3 cm in Group II, and the free flow was of 80.3 ml/min in Group I, and of 95.5 ml/min in Group II. No morphological anatomic and histological differences were observed in the compared groups. The diameters of the radial artery grafts, which were calculated by quantitative angiography in the postoperative period, were similar (2.66 mm in Group I, and 2.53 mm in Group II), as well as the flow variables (blood flow of 54.9 ml/min in Group I, and of 44.28 ml/min in Group II, and a flow reserve of 2.12 in Group I, and of 2 in Group II). On the other hand, the cinecoronariography revealed the presence of an occlusion in one graft, and of stenosis in five grafts of Group II, while Group I presented stenosis in only one radial artery graft (p = 0.091). CONCLUSIONS: The aortic coronary grafts of the radial artery displayed good functional and hemodynamic early performance. There was no difference between the groups regarding functional and hemodynamic early performance, and the morphological anatomical and histological features.
123

Comparação das dimensões das artérias coronárias e da composição da placa aterosclerótica entre a angiografia coronária por tomografia de 64 colunas de detectores e a ultrassonografia intracoronária com a técnica de histologia virtual / Comparison of coronary artery dimensions and atherosclerotic plaque composition between coronary angiography by 64-slice computed tomography and by virtual histology intravascular ultrasound technique

João Luiz de Alencar Araripe Falcão 24 February 2010 (has links)
Introdução: No momento, pouco se conhece sobre o desempenho diagnóstico da angiotomografia de coronárias com 64 colunas de detectores (Angio-TC 64) frente aos achados do ultrassom intracoronário com técnica de histologia virtual (USIC-HV). Este estudo compara a capacidade diagnóstica de ambos os métodos para a avaliação das dimensões vasculares e para avaliação da composição da placa aterosclerótica através da análise de toda extensão dos três vasos epicárdicos principais. Métodos e Resultados: Um total de 21 pacientes com diagnóstico de doença arterial coronária obstrutiva foi incluído neste estudo. Angio-TC 64 foi realizada em todos os pacientes antes da realização do USIC-HV, com intervalo<72horas entre os dois exames. No total, 70 vasos foram avaliados (3,3 vasos por paciente) e divididos em 641 subsegmentos de 4 mm de extensão cada. Um total de 5.972 cortes seccionais de USIC-HV e 5.233 cortes seccionais da Angio-TC 64 foram analisados. As medidas de área luminar, área do vaso, área da parede arterial e carga de placa à Angio-TC 64 e ao USIC-HV foram significativamente correlacionadas (r-Spearman: 0,81; 0,78; 0,55 e 0,49; respectivamente - p<0,001 para todas as correlações). A Angio-TC 64 subestimou a área luminar ao USIC-HV (em mediana: 0,4mm2 ,variando entre -5,6 mm2 e 10,2 mm2). A Angio-TC 64 superestimou a área do vaso, a área da parede arterial (placa+média) e a carga de placa (em mediana: 3,0 mm2; 3,2 mm2 e 13,9%, respectivamente). O aumento da densidade média da placa à Angio-TC 64 foi significativamente associado com o aumento da contribuição percentual dos componentes cálcio denso e núcleo necrótico ao USIC-HV. O aumento da densidade média da placa à Angio-TC 64 foi significativamente associado com a diminuição da contribuição percentual do componente fibro-lipídico ao USIC-HV. Parâmetros de qualidade da imagem (atenuação luminar, ruído da atenuação luminar e relação sinal ruído) influenciaram significativamente os resultados da Angio-TC 64. Conclusão: Nosso estudo demonstra que as imagens da Angio-TC 64 se correlacionam significativamente com as imagens do USIC-HV. Estes achados indicam que a Angio-TC 64 pode ser uma ferramenta útil para a avaliação quantitativa da luz arterial e da placa aterosclerótica; bem como para a avaliação da composição da placa aterosclerótica in vivo / Background: Currently, little is known about the comparative diagnostic performance for coronary assessment of 64-slice multidetector computed tomography (64-MDCT) versus virtual histology intravascular ultrasound technique (VH-IVUS). The present study compares the diagnostic ability of both methods for the evaluation of coronary lumen and vessel wall dimensions as well as plaque composition in a three-vessel whole-artery analysis protocol. Methods and Results: A total of 21 patients with diagnosed obstructive coronary artery disease was included. 64-MDCT was performed within 72 hours before the VH-IVUS examination. Overall, 70 vessels were imaged (3.3 vessels per patient), and divided into 641 subsegments of 4 mm each. A total of 5,972 VH-IVUS cross-sections and 5,233 64-MDCT cross-sections were analyzed. 64-MDCT and VH-IVUS measurements for luminar area, vessel area, arterial wall area (plaque plus media area) and plaque burden were significantly correlated (r-Spearman: 0.81; 0.78; 0.55 e 0.49; respectively - p<0,001 for all correlations). 64-MDCT underestimated VH-IVUS measurements for luminar area (median: 0.4mm2, range: -5.6 mm2 to 10,2 mm2). 64-MDCT overestimated VH-IVUS measurements for vessel area, arterial wall area, and plaque burden (median: 3.0 mm2; 3.2 mm2 e 13.9%, respectively). Increasing plaque density at 64-MDCT was significantly associated with increasing dense calcium and necrotic core percent composition at VH-IVUS. Increasing plaque density at 64-MDCT was significantly associated with decreasing fibrofatty percent composition, and decreasing necrosis-to-calcium ratio at VH-IVUS. Image quality parameters (i.e. lumen attenuation, image noise, signal-to-noise ratio) significantly influenced the results of 64-MDCT. Conclusion: Our study shows that 64-MDCT imaging significantly correlates with VH-IVUS. These findings indicate that 64-MDCT may be a useful non-invasive tool for quantitative evaluation of lumen and plaque parameters, as well as for the in vivo assessment of atherosclerotic plaque composition
124

Uso da angiografia coronária por tomografia computadorizada na avaliação prognóstica de pacientes com suspeita de doença arterial coronária / Coronary computed tomography angiography to evaluate prognosis in patients with suspected coronary artery disease

Bittencourt, Márcio Sommer 24 July 2014 (has links)
Introdução: Poucos estudos avaliaram o valor prognóstico em longo prazo da presença, extensão e gravidade da doença arterial coronária (DAC) detectada pela angiotomografia computadorizada de artérias coronárias (TCcor). Métodos: Todos os pacientes consecutivos sem DAC prévia que realizaram TCcor para avaliar DAC foram incluídos. Os resultados da TCcor foram classificados como normal, DAC não-obstrutiva (estenose < 50%), ou obstrutiva (>= 50%). Além disso, com base no número de segmentos com a doença, a DAC foi classificada como não-extensa (<= 4 segmentos) ou extensa (> 4 segmentos). Os pacientes foram acompanhados para o desfecho primário de eventos cardiovasculares (CV) incluindo morte ou infarto do miocárdio (IAM) e um desfecho secundário dos eventos cardiovasculares adversos maiores, constituído por morte CV, IAM ou revascularização coronária tardia (> 90 dias). Resultados: Entre 3242 pacientes acompanhados por uma média de 3,6 ± 1,8 anos, ocorreram 92 (2,8%) eventos primários e 195 (6,0%) apresentaram o desfecho secundário. Em uma análise multivariada, foram associados com aumento de eventos a presença de DAC extensa não-obstrutiva (hazard ratio (HR): 3.1, intervalo de confiança de 95% (IC): 1,5-6,5); não-extensa obstrutiva (HR: 3,0, IC 95%: 1,3 - 7,0) e DAC obstrutiva extensa (HR: 3,9, IC 95%: 2,1-7,2), enquanto os não-extensiva CAD não-obstrutiva não esteve associada a eventos (HR: 1,3, IC 95%: 0,6-2,4). A adição da extensão da placa a um modelo que incluía probabilidade clínica de DAC, assim como a presença e gravidade de DAC resultou na melhoria da predição de eventos CV. Conclusão: Entre os pacientes com DAC não obstrutiva, aqueles com mais de 4 segmentos com doença apresentaram uma maior taxa de CV morte ou MI, comparáveis aos que têm doença obstrutiva com <= 4 segmentos. Mesmo entre os pacientes com DAC obstrutiva, maior extensão de placa esteve associado com maior taxa de eventos. Estes resultados sugerem que, independentemente da presença de estenose, a extensão da placa não-obstrutiva reforça a avaliação de risco além dos dados clínicos e outros achados TCcor / Introduction: There is limited prior data on the long-term prognostic value of the presence, extent and severity of both non-obstructive and obstructive CAD detected by coronary computed tomography angiography (CCTA). Methods: All consecutive patients without prior CAD referred for CCTA to evaluate for CAD were included. CCTA findings were classified as normal, non-obstructive (< 50% stenosis) or obstructive (>= 50%) disease. Additionally, based on the number of segments with disease, extent of CAD was classified as non-extensive (<=4 segments) or extensive (> 4 segments). Patients were followed for a primary endpoint of cardiovascular (CV) death or myocardial infarction (MI) and a secondary endpoint of major adverse cardiovascular events (MACE) consisting of CV death, MI or late coronary revascularization (> 90 days). Results: Among 3242 patients followed for a mean of 3.6±1.8 years, 92 (2.8%) patients who experienced the primary endpoints and 195 (6.0%) experienced the secondary endpoint. In a multivariable analysis, the presence of extensive non-obstructive CAD (hazard ratio (HR): 3.1, 95% confidence interval (CI): 1.5 - 6.5); non-extensive obstructive (HR: 3.0, 95%CI: 1.3 - 7.0) and extensive obstructive CAD (HR: 3.9, 95%CI: 2.1 - 7.2) were associated with increase in the rate of the primary endpoint, while non-extensive non-obstructive CAD was not (HR: 1.3, 95%CI: 0.6 - 2.4). The addition of the extent of plaque to a model, which included clinical probability of CAD as well as the presence and severity of CAD, resulted in improved prediction of all endpoints. Conclusion: Among patients with non-obstructive CAD, those with more than 4 segments with disease experienced a higher rate CV death or MI, comparable to those who have obstructive disease with <= 4 diseased segments. Even among patients with obstructive CAD, greater extent of non-obstructive plaque was associated with higher event rate. These findings suggest that regardless of whether stenosis is present or absent, the extent of non-obstructive plaque enhances risk assessment beyond clinical data and other CCTA findings
125

Uso da angiografia coronária por tomografia computadorizada na avaliação prognóstica de pacientes com suspeita de doença arterial coronária / Coronary computed tomography angiography to evaluate prognosis in patients with suspected coronary artery disease

Márcio Sommer Bittencourt 24 July 2014 (has links)
Introdução: Poucos estudos avaliaram o valor prognóstico em longo prazo da presença, extensão e gravidade da doença arterial coronária (DAC) detectada pela angiotomografia computadorizada de artérias coronárias (TCcor). Métodos: Todos os pacientes consecutivos sem DAC prévia que realizaram TCcor para avaliar DAC foram incluídos. Os resultados da TCcor foram classificados como normal, DAC não-obstrutiva (estenose < 50%), ou obstrutiva (>= 50%). Além disso, com base no número de segmentos com a doença, a DAC foi classificada como não-extensa (<= 4 segmentos) ou extensa (> 4 segmentos). Os pacientes foram acompanhados para o desfecho primário de eventos cardiovasculares (CV) incluindo morte ou infarto do miocárdio (IAM) e um desfecho secundário dos eventos cardiovasculares adversos maiores, constituído por morte CV, IAM ou revascularização coronária tardia (> 90 dias). Resultados: Entre 3242 pacientes acompanhados por uma média de 3,6 ± 1,8 anos, ocorreram 92 (2,8%) eventos primários e 195 (6,0%) apresentaram o desfecho secundário. Em uma análise multivariada, foram associados com aumento de eventos a presença de DAC extensa não-obstrutiva (hazard ratio (HR): 3.1, intervalo de confiança de 95% (IC): 1,5-6,5); não-extensa obstrutiva (HR: 3,0, IC 95%: 1,3 - 7,0) e DAC obstrutiva extensa (HR: 3,9, IC 95%: 2,1-7,2), enquanto os não-extensiva CAD não-obstrutiva não esteve associada a eventos (HR: 1,3, IC 95%: 0,6-2,4). A adição da extensão da placa a um modelo que incluía probabilidade clínica de DAC, assim como a presença e gravidade de DAC resultou na melhoria da predição de eventos CV. Conclusão: Entre os pacientes com DAC não obstrutiva, aqueles com mais de 4 segmentos com doença apresentaram uma maior taxa de CV morte ou MI, comparáveis aos que têm doença obstrutiva com <= 4 segmentos. Mesmo entre os pacientes com DAC obstrutiva, maior extensão de placa esteve associado com maior taxa de eventos. Estes resultados sugerem que, independentemente da presença de estenose, a extensão da placa não-obstrutiva reforça a avaliação de risco além dos dados clínicos e outros achados TCcor / Introduction: There is limited prior data on the long-term prognostic value of the presence, extent and severity of both non-obstructive and obstructive CAD detected by coronary computed tomography angiography (CCTA). Methods: All consecutive patients without prior CAD referred for CCTA to evaluate for CAD were included. CCTA findings were classified as normal, non-obstructive (< 50% stenosis) or obstructive (>= 50%) disease. Additionally, based on the number of segments with disease, extent of CAD was classified as non-extensive (<=4 segments) or extensive (> 4 segments). Patients were followed for a primary endpoint of cardiovascular (CV) death or myocardial infarction (MI) and a secondary endpoint of major adverse cardiovascular events (MACE) consisting of CV death, MI or late coronary revascularization (> 90 days). Results: Among 3242 patients followed for a mean of 3.6±1.8 years, 92 (2.8%) patients who experienced the primary endpoints and 195 (6.0%) experienced the secondary endpoint. In a multivariable analysis, the presence of extensive non-obstructive CAD (hazard ratio (HR): 3.1, 95% confidence interval (CI): 1.5 - 6.5); non-extensive obstructive (HR: 3.0, 95%CI: 1.3 - 7.0) and extensive obstructive CAD (HR: 3.9, 95%CI: 2.1 - 7.2) were associated with increase in the rate of the primary endpoint, while non-extensive non-obstructive CAD was not (HR: 1.3, 95%CI: 0.6 - 2.4). The addition of the extent of plaque to a model, which included clinical probability of CAD as well as the presence and severity of CAD, resulted in improved prediction of all endpoints. Conclusion: Among patients with non-obstructive CAD, those with more than 4 segments with disease experienced a higher rate CV death or MI, comparable to those who have obstructive disease with <= 4 diseased segments. Even among patients with obstructive CAD, greater extent of non-obstructive plaque was associated with higher event rate. These findings suggest that regardless of whether stenosis is present or absent, the extent of non-obstructive plaque enhances risk assessment beyond clinical data and other CCTA findings

Page generated in 0.029 seconds