• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 120
  • 3
  • 1
  • Tagged with
  • 125
  • 94
  • 48
  • 46
  • 35
  • 32
  • 32
  • 32
  • 31
  • 29
  • 28
  • 24
  • 24
  • 20
  • 20
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
91

Estudo dosimétrico em cardiologia intervencionista: dose paciente e dose trabalhador

do Socorro Rocha da Silva, Maria 31 January 2011 (has links)
Made available in DSpace on 2014-06-12T23:13:58Z (GMT). No. of bitstreams: 2 arquivo3314_1.pdf: 5772499 bytes, checksum: 7f9d795fe1b6dce103b1a1696b26eb1a (MD5) license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) Previous issue date: 2011 / Os avanços tecnológicos na área da geração de imagens médicas com radiações ionizantes possibilitaram a realização de intervenções invasivas que têm beneficiado diversas áreas da medicina, destacando-se entre essas as intervenções em cardiologia intervencionista. Apesar dos benefícios, os procedimentos intervencionistas geralmente envolvem o uso de longos tempos de exposição à radiação e representam, para pacientes e trabalhadores, um risco maior do que o de outros procedimentos nos quais também há exposição à radiação. Este trabalho apresenta os resultados da dosimetria realizada em médicos e pacientes (pediátricos e adultos) durante intervenções cardíacas percutâneas e procedimentos de diagnóstico, realizados no período de abril de 2007 a agosto de 2010, em um hospital de referência na cidade de Recife, Pernambuco. As medidas dosimétricas foram tomadas em 143 procedimentos, dos quais 118 foram realizados em pacientes adultos e 25 em pacientes pediátricos, estes com doença cardíaca congênita. Os procedimentos foram realizados por meio de um angiógrafo monoplanar Philips (modelo Allura 12), equipado com intensificador de imagem. A dosimetria de pacientes foi realizada pelo emprego de filmes radiocrômicos e de parâmetros de indicação de dose apresentados pelo equipamento angiográfico; e para a dosimetria nos médicos se utilizaram dosímetros termoluminescentes distribuídos no corpo e nas vestimentas de proteção dos profissionais. Durante os procedimentos clínicos, foram registrados parâmetros de irradiação e informações como: número de imagens, tempo acumulado em fluoroscopia; magnitude do kerma ar cumulativo no ponto de referência IRP [Ka,r], entre outras. Os resultados da dosimetria de pacientes mostraram valores de kerma ar na superfície de entrada da pele do paciente [Ka,e], variando de 240 a 5.897 mGy, nos pacientes adultos, e de 45 a 1.079 mGy nos pacientes pediátricos. A máxima dose absorvida na superfície (MDA) da pele do paciente variou de 649 a 4.180 mGy, nos pacientes adultos, e de 214 a 487 mGy, nos pacientes pediátricos. Seguindo orientações de guias de acompanhamento de pacientes, os pacientes que apresentaram MDA maior que 3 Gy ou Ka,r maior que 5 Gy foram avaliados, pelos médicos, após 14 dias do procedimento e não se observou a ocorrência de lesões. Com relação aos médicos, a dose efetiva média por procedimento foi 5,2 μSv em procedimentos de diagnóstico com pacientes adultos e de 4,5 μSv com pacientes pediátricos. Nos procedimentos de intervenção, os valores foram 10,8 μSv e 6,4 μSv, em procedimentos com pacientes adultos e pediátricos, respectivamente. Os valores de dose equivalente por procedimento, mais altos, medidos no corpo dos médicos, foram: 922 μSv no pé esquerdo, 514 μSv no pé direito, 382 μSv nas mãos e 150 μSv nos olhos, em procedimentos com pacientes adultos. Com pacientes pediátricos, os valores foram: 123, 127, 1.188 e 224 μSv, respectivamente. A ausência de acessórios de proteção (tela e saiote pumblíferos) e EPIs específicos (óculos e luvas) são explicações para os valores altos registrados. Dependendo do número de procedimentos, as doses recebidas pelos médicos podem exceder os limites de dose anual (150 mSv para o cristalino dos olhos e 500 mSv para extremidades) estabelecidos por normas nacionais e internacionais
92

Segmentos coronarianos sem obstrução angiográfica em indivíduos com doença aterosclerótica coronária: caracterização através do ultrassom intravascular com histologia virtual / Coronary segments without luminal stenosis by angiography in patients with atherosclerotic coronary disease: a comprehensive evaluation with intravascular ultrasound and virtual histology

Gustavo Rique Morais 25 September 2015 (has links)
Introdução: Segmentos coronários com doença aterosclerótica manifesta podem coexistir no mesmo paciente com artérias normais à angiografia. Porém as características desses vasos angiograficamente normais permanecem pouco estudadas. O presente estudo visa a descrição in vivo, através do ultrassom intravascular com histologia virtual, da presença, grau de acometimento e composição da doença coronária aterosclerótica em artérias normais ou quase normais (irregularidades parietais) do ponto de vista angiográfico, em pacientes com doença coronária obstrutiva em outros territórios. Métodos: Pacientes com doença coronária obstrutiva foram selecionados de forma prospectiva e foram submetidos a estudo ultrassonográfico com histologia virtual de múltiplos vasos. Artérias epicárdicas principais foram classificadas em quatro grupos baseado na sua aparência angiográfica: 1) vasos completamente normais, 2) vasos com irregularidades parietais, 3) vasos com pelo menos uma estenose discreta, 4) vasos com pelo menos uma estenose moderada ou importante. Para os vasos com estenoses luminais (grupos 3 e 4 acima), apenas segmentos que não possuíam lesão maior ou igual a 30% (não obstrutivos) foram incluídos na análise. Resultados: Um total de 60 pacientes (154 vasos) foram incluídos no estudo. Vasos angiograficamente normais apresentaram menor carga de placa, menos componente necrótico, menor densidade de lesões e quase nenhuma placa com características de alto risco. Entretanto, em vasos com irregularidades parietais encontramos uma maior carga de placa com elevada densidade de lesões pelo ultrassom intravascular similar a segmentos \"não obstrutivos\" de vasos com estenoses luminais evidentes pela angiografia em outro ponto. Conclusão: Artérias coronárias completamente normais pela angiografia parecem apresentar pouca doença aterosclerótica. Entretanto, vasos com irregularidades parietais estão associados com um maior acometimento aterosclerótico e elevada densidade placas de alto risco, achado este que não pode ser rapidamente obtido com o uso apenas da angiografia coronária / Background: Extensively diseased arteries may co-exist, in the same patient, with coronary vessels with a normal appearance by angiography. Thus far, however, the characteristics of the latter remain poorly described. The present study aims to evaluate in vivo, using intravascular ultrasound (IVUS) with radiofrequency backscatter analysis (RF), the presence, degree, and composition of atherosclerosis in arteries with angiographically normal or near-normal appearance, in patients with diagnosed coronary disease in other territories. Methods: Patients with diagnosed obstructive coronary disease were prospectively selected and underwent protocol-mandated multi-vessel IVUS-RF. Major epicardial branches were classified into four groups based on their angiographic appearance: 1) completely normal-looking; 2) near-normal; 3) at least one mild stenosis; 4) at least one severe or moderate stenosis. For vessels with lumen stenosis (groups 3 and 4 above), only \"non-stenotic\" portions were included in the IVUS analysis. Results: A total of 60 patients (154 vessels) comprised the study population. Completely normal-looking vessels had lower plaque burden, lower necrotic component, lower density of lesions, and almost null high-risk plaques. Conversely, a nearnormal aspect, with only subtle lumen irregularities by angiography, was associated with increased disease burden, with an elevated density of plaques with high-risk features, similar to \"non-stenotic\" portions of vessels with obvious atherosclerosis elsewhere. Conclusions: Coronary vessels with a completely normal-looking appearance by angiography appear to have little atherosclerosis. Conversely, yet mild luminal irregularities by angiography are associated with increased disease burden and elevated density of high-risk plaques by IVUS, which cannot be readily assessable by angiography alone. Descriptors: angiography; atherosclerosis; coronary artery disease; plaque, atherosclerotic; ultrasonography, interventional; coronary vessels.Background: Extensively diseased arteries may co-exist, in the same patient, with coronary vessels with a normal appearance by angiography. Thus far, however, the characteristics of the latter remain poorly described. The present study aims to evaluate in vivo, using intravascular ultrasound (IVUS) with radiofrequency backscatter analysis (RF), the presence, degree, and composition of atherosclerosis in arteries with angiographically normal or near-normal appearance, in patients with diagnosed coronary disease in other territories. Methods: Patients with diagnosed obstructive coronary disease were prospectively selected and underwent protocol-mandated multi-vessel IVUS-RF. Major epicardial branches were classified into four groups based on their angiographic appearance: 1) completely normal-looking; 2) near-normal; 3) at least one mild stenosis; 4) at least one severe or moderate stenosis. For vessels with lumen stenosis (groups 3 and 4 above), only \"non-stenotic\" portions were included in the IVUS analysis. Results: A total of 60 patients (154 vessels) comprised the study population. Completely normal-looking vessels had lower plaque burden, lower necrotic component, lower density of lesions, and almost null high-risk plaques. Conversely, a nearnormal aspect, with only subtle lumen irregularities by angiography, was associated with increased disease burden, with an elevated density of plaques with high-risk features, similar to \"non-stenotic\" portions of vessels with obvious atherosclerosis elsewhere. Conclusions: Coronary vessels with a completely normal-looking appearance by angiography appear to have little atherosclerosis. Conversely, yet mild luminal irregularities by angiography are associated with increased disease burden and elevated density of high-risk plaques by IVUS, which cannot be readily assessable by angiography alone
93

Cintilografia do miocárdio com tecnécio 99m-MIBI associada à administração de adenosina em portadores de doença arterial coronária: implicações para a tomada de decisão / Adenosine myocardial perfusion SPECT with Tc- 99m - MIBI in patients with obstructive coronary artery disease: implications for making clinical decisions

Luiz Eduardo Mastrocolla 25 November 2003 (has links)
A cintilografia do miocárdio com radioisótopos e associada à administração de vasodilatadores coronários, é método estabelecido para o diagnóstico e estratificação de risco da coronariopatia aterosclerótica obstrutiva, utilizando a angiografia coronária como padrão. As capacidades diagnóstica e prognóstica ótimas são habitualmente obtidas na presença de lesões graves, sendo que para para graus menores de obstrução, de caracterização mais difícil pela própria angiografia coronária, observa-se menor acurácia da prova cintilográfica. Para testar a hipótese de que a cintilografia com adenosina correlaciona-se com os diâmetros e áreas da luz arterial, estabelecidos pela angiografia coronária quantitativa (ACQ) e o ultra-som intracoronário (UIC), avaliando a repercussão funcional das lesões, optamos por avaliar o método em portadores de doença arterial coronária caracterizada como de difícil manejo dentro do processo de decisão clínica. Desta forma, submetemos 70 pacientes (P) consecutivos à cintilografia do miocárdio com 99mTc-MIBI associada à injeção de adenosina, com média de idades de 60,6 anos, sendo 55,7% do sexo masculino, excluindo-se aqueles com angina instável, infarto do miocárdio de evolução recente, bloqueio do ramo esquerdo e outras condições inerentes à realização da prova farmacológica. Estabelecemos como objetivos: 1) a associação dos resultados da prova com as variáveis obtidas da ACQ e UIC; 2) a determinação da acurácia da prova, definida em relação a valores de estenose porcentual do diâmetro da luz, iguais a 50% e obtidos à análise visual da angiografia (%E) e ACQ (%Est); do diâmetro mínimo da luz (DML) e da área mínima da luz (AML) no local de maior estreitamento, iguais a 1,5 mm e 4 mm2 respectivamente, obtidos à ACQ e ao UIC; e da área porcentual de obstrução (AO%), igual a 70%, ao UIC; 3) avaliar a segurança do método pela análise das respostas clínicas, hemodinâmicas e eletrocardiográficas (ECG) ao estímulo farmacológico. A angiografia de admissão evidenciou 105 lesões obstrutivas nos 70 P, com doença em um, dois e três ou mais vasos em 43 P (61,4%), 20 P (28,6%) e 7 P (10%) respectivamente, e envolvimento predominante da artéria descendente anterior. As médias dos valores de %E foram de 49,94% (DP 12,69) e de %Est de 44,20% (DP 10,37), com boa correlação entre os dois métodos (r=0,79). Os resultados da cintilografia foram expressos como variáveis dicotômicas, definindo provas normais e alteradas ou normais e isquêmicas, sendo então associados às médias das variáveis da angiografia e do UIC. Os achados de qualquer alteração da captação às imagens cintilográficas, de hipocaptação sugestiva de isquemia e de alterações do espessamento correlacionaram-se à maior AO% ao UIC. Adicionalmente, as respostas clínicas, do ECG e o resultado das imagens de perfusão foram considerados em conjunto, criando-se uma variável dicotômica para, da mesma forma, traduzir provas normais e alteradas ou isquêmicas. A presença de isquemia, avaliada pela análise global da prova, associou-se a menores DML e AML à ACQ e ao UIC: DML isquêmico x normal pela ACQ= 1,49 mm (DP 0,34) x 1,71 mm, (DP 0,49), p < 0,05; DML isquêmico x normal pelo UIC= 1,63 mm (DP 0,38) x 1,97 mm (DP 0,50), p < 0,05; AML isquêmica x normal pela ACQ= 3,74 mm2 (DP 1,78) x 5,00 mm2 (DP 2,65), p<0,05; e AML isquêmica x normal pelo UIC= 2,74 mm2 (DP 1,38) x 4,01 mm2 (DP 1,79), p < 0,05). A acurácia da prova, expressa pela sensibilidade (S), especificidade (E), valores preditivos positivo (VPP) e negativo (VPN) foi calculada em relação aos valores de corte estabelecidos das variáveis quantitativas. As respostas do ECG, discriminantes em relação à E%, mostraram S=37% e E=77%. As alterações da captação consideradas isquêmicas e associadas à AO% ao UIC evidenciaram S=75%; E=64%; VPP=43% e VPN=88%. Os resultados globais da prova que se mostraram discriminantes, apresentaram os seguintes índices: Método Variável S (%) E (%) VPP (%) VPN (%) ACQ DML 78 44 51 73 ACQ AML 71 43 65 50 UIC DML 93 39 50 90 UIC AML 83 56 86 50 Conclusões: Para a população estudada, a cintilografia com 99mTc-MIBI e injeção de adenosina correlaciona-se à AO% ao UIC, considerando-se as imagens de perfusão e de espessamento ventricular. Na avaliação dos resultados globais, caracterizados a partir da adição dos dados do ECG e das manifestações clínicas durante a injeção de adenosina às imagens, observa-se associação com os diâmetros e as áreas da luz nos locais de maior obstrução, obtidos à ACQ e ao UIC. Adicionalmente, pela análise das respostas clínicas, ECG e hemodinâmicas, o método mostrou-se seguro e factível / Radionuclide myocardial perfusion imaging (MPI) with 99mTechnetium - MIBI in combination with pharmacological vasodilation is used to detect ischemia and for the risk stratification of obstructive coronary artery disease (CAD), employing coronary angiography as gold standard. The best accuracy is found in presence of high-grade coronary stenosis, limited when less severity is seen. To test the hyphotesis that adenosine SPECT MPI correlates with coronary lesion lumen diameter and area dimensions by quantitative coronary angiography (QCA) and intravascular ultrasound (IVUS), evaluating the functional significance of coronary stenosis, we intent to test the method in patients (P) with known coronary disease. Seventy consecutive P (55,7% male, mean age 60,6) were referred to adenosine SPECT 99mTc-MIBI. Were excluded those one with unstable angina, recent myocardial infarction, left bundle branch block, and any other conditions that makes the pharmacological stress impossible. The objectives were: 1) to establish the association between the clinical, EKG and scintigraphic findings with the QCA and IVUS variables; 2) to determine the accuracy of the test, based upon defined discriminant values of 50% luminal diameter narrowing by visual analysis of coronary angiography and QCA; minimum luminal diameter (MLD) and minimum luminal area (MLA) of 1,5 mm and 4 mm2 respectively, derived from QCA and IVUS and luminal percent area stenosis (AS%) of 70% by IVUS; 3) to determine the safety and feasibility of the method, throughout clinical, hemodinamic and electrocardiographic (EKG) responses to pharmacological vasodilation. The coronary angiography revealed 105 native artery lesions in 70 P, with one, two and multivessel disease in 43 p (61,4%), 20 p (28,6%) and 7 p (10%) respectively. Left anterior descending artery disease was present in 58%, 70% and 86% of the patients, respectively. Mean percent diameter stenosis values were 49,94% (SD 12,69) by visual analysis of angiography and 44,20% (SD 10,37) by QCA. Myocardial scintigraphy findings were defined as dicotomic variables categorized as normal x abnormal uptake or normal x reversible uptake; these findings were associated with visual, QCA and IVUS variables through mean comparison (t test). Chest pain during adenosine infusion was not related with greater stenosis severity, but ischemic EKG abnormalities were associated with different mean values when percent diameter stenosis derived from visual analysis was compared (p < 0,05). Therefore, any myocardial uptake abnormality, reversible uptake or any tickening abnormalities were correlated with AS% by IVUS (p< 0,05). Finally, the clinical, electrocardiographic and scintigraphic findings were considered together and categorized into global abnormal x normal response or global ischemic x normal response. Global ischemic response was associated to smaller mean values of MLD and MLA by QCA and IVUS: ischemic x normal MLD by QCA = 1,49 ± 0,34 mm x 1,71 ± 0,49 mm, p< 0,05; ischemic x normal MLD by IVUS = 1,63 ± 0,38 mm x 1,97 ± 0,50 mm, p<0,05; ischemic x normal MLA by QCA = 3,74 ± 1,78 mm2 x 5,00 ± 2,65 mm2, p<0,05; and ischemic x normal MLA by IVUS = 2,74 ± 1,38 mm2 x 4,01 ± 1,79 mm2, p<0,05). Sensitivity (S), Specificity (Sp), Predictive positive (PPV) and negative values (PNV) were calculated based upon discriminate values from visual, QCA and IVUS. The EKG response, related to percent diameter luminal stenosis by visual analysis of angiography showed S=37% and Sp=77%. Reversible uptake had S=75%; Sp=64%; PPV=43% and PNV=88%. The global ischemic findings that were discriminant are described bellow: Method Variable S (%) Sp (%) PPV (%) PNV (%) QCA DML 78 44 51 73 QCA AML 71 43 65 50 IVUS DML 93 39 50 90 IVUS AML 83 56 86 50 Considering the studied population with known coronary artery disease, perfusion and thickening adenosine SPECT results are associated with AS% by IVUS. When Clinical, EKG and scintigraphic findings are considered together as a dicotomic variable (ischemia x normal), correlation is observed between MLD and MLA by QCA and IVUS. Also, the method is considered feasible and safe, when clinical, hemodinamic and EKG abnormalities are evaluated
94

Redukce rizika tichých a symptomatických mozkových infarktů pomocí sonolýzy při koronární angioplastice a stentingu / Sonolysis in Risk Reduction of Symptomatic and Silent Brain Infarctions during Coronary Angioplasty and Stenting

Viszlayová, Daša January 2020 (has links)
Background: Cerebral complications of coronary catheterizations are transient ischemic attack (TIA) and stroke. Silent stroke (SCI) does not cause acute neurological dysfunction. It might cause many disorders including dementia. Sonolysis is therapeutic method. Sonolysis should be the method for reducing the risk of symptomatic and asymptomatic brain ischemic lesions in patients undergoing elective coronary angioplasty or stenting. Aims: To analyse patients with cardiac disease indicated for elective coronary catheterization: 1) Assess the incidence of acute/subacute SCI on brain magnetic resonance (MR) imaging; 2) Investigate factors influencing the frequency and type of microembolic signals (MES) detected using transcranial Doppler (TCD) in patients undergoing elective coronary intervention, and to correlate the frequency and type of MES with detection of new brain ischemic lesions using MR. Examine changes in cognitive function at 30 days post procedure in relation to pretreatment scores; 3) Test the clinical efficacy and safety of perioperative sonolysis in patients undergoing elective coronary catheterization. Methods: 1) 144 patients were enrolled to the study. Brain MR was performed before cardiac intervention. The presence of acute and subacute SCI was evaluated, SCI volume was measured and risk...
95

Alterações de difusão e perfusão cerebral por RM em angioplastia carotídea com \"stent\" sob proteção cerebral por filtros / Changes in diffusion and perfusion weighted magnetic resonance imaging in carotid angioplasty with stenting under cerebral protection by filters

Sá Júnior, Antenor Tavares de 09 October 2009 (has links)
INTRODUÇÃO: A angioplastia carotídea com stent (ACS) sob proteção cerebral é opção terapêutica em pacientes com estenose carotídea. Existe o risco de embolia apesar da utilização do filtro e as modificações na perfusão cerebral após tratamento da estenose carotídea não são claras. O propósito deste estudo é avaliar, após ACS sob proteção cerebral por filtros, modificações nas seqüências de RM de difusão (DWI) e perfusão (PWI), correlacionando-as com os aspectos técnicos da ACS, com as características da estenose e com dados demográficos dos pacientes. MÉTODO: Trinta e seis pacientes portadores de estenose carotídea com idade média de 72,08 anos foram submetidos a exame de RM um dia antes e até 72 horas após a ACS com filtro de proteção. Todos os pacientes eram assintomáticos após a ACS. Áreas de restrição na DWI após a ACS foram correlacionadas com aspectos demográficos, com aspectos da técnica de angioplastia e com a presença de infartos prévios por RM. Os parâmetros CBV volume sanguíneo cerebral, MTT tempo de trânsito médio e TTP tempo para o pico são empregados para análise por PWI. RESULTADOS: Na DWI, 18 de 36 (50,00%) pacientes apresentaram novos focos (NF) de restrição na DWI após ACS. Todos os NF foram clinicamente silenciosos (100%). Estes NF eram localizados em território cerebral nutrido pela artéria carótida submetida à ACS em 77,19% e menores que 10 mm em 91,53%. Os NF em território cerebral não irrigado pela artéria carótida submetida à angioplastia correspondiam a 22,81% destes. A presença de infartos cerebrais prévios na RM foi o único fator com influência no aparecimento de NF (p=0,037). Fatores demográficos e aspectos relacionados com a técnica de angioplastia não tiveram importância na gênese dos NF. Na PWI foi observada melhora nos parâmetros temporais TTP (p<0,001) e MTT (p=0,019) quando comparados de forma normalizada em relação ao território contralateral. CONCLUSÃO: Os novos focos de restrição na DWI após ACS (NF) foram mais comuns no território ipsilateral (77,19%), no entanto houve NF no território contralateral à ACS (22,81%), possivelmente, associados ao cateterismo diagnóstico. Os NF, na sua maioria, são de pequeno diâmetro (<10 mm em 91,53%). Melhora precoce na PWI, observada nos dados normalizados, foi demonstrada nos parâmetros temporais (TTP e MTT). / INTRODUCTION: Carotid angioplasty with stent (CAS) under cerebral protection is a therapeutic option in patients with carotid stenosis. There is a risk of embolism even with a filter, and changes in cerebral perfusion after treatment are not clearly understood. The purpose of this study was to evaluate changes in diffusion- (DWI) and perfusion- (PWI) weighted magnetic resonance imaging (MRI) sequences correlating them with the technical aspects of CAS, stenosis characteristics and patient demographic data. METHODS: Thirty-six carotid stenosis patients with an mean age of 72.08 years were submitted to MRI exam one day before and up to 72 hours after CAS with filter protection. All patients were asymptomatic after CAS. Areas of restriction on DWI were correlated to demographic aspects, technique of angioplasty as well the presence of previous stroke by MRI. The parameters, CBV - cerebral blood volume; MTT - mean transit time, and TTP- time to peak, are used for PWI analysis. RESULTS: Eighteen of the 36 patients (50.00%) presented new focus (NF) of restriction by DWI after CAS. All new focus were clinically silent. The NF were located in the cerebral area fed by the carotid artery submitted to CAS in 77.19% and smaller than 10mm in 91.53%. NF in cerebral area not irrigated by carotid artery submitted by angioplasty correspond to 22,81 %. The presence of previous ischemic lesion on MRI was the only factor which influenced the appearance of NF (p=0.037). Demographic factors and aspects related to angioplasty technique had no importance on NF genesis. Improvement in PWI timing parameters - TTP (p<0.001) and MTT (p=0.019) were observed in relation to the contralateral territory (normalized data). CONCLUSION: The restriction NF in the DWI after CAS are more common in the ipsilateral territory (77.19%), however there were some NF in the contralateral territory to the CAS (22.81%), possibly associated with diagnostic catheterization. Most of the NF were small in diameter (<10mm in 91.53%). Short-term improvement in PWI were demonstrated by normalized timing parameters (TTP and MTT).
96

Tratamento endovascular das dissecções e pseudoaneurismas da artéria vertebral. / Endovascular treatment of dissections and pseudoaneurysms of the vertebral artery.

Puglia Junior, Paulo 11 November 1999 (has links)
As dissecções da artéria vertebral causam acidentes vasculares cerebrais isquêmicos e hemorrágicos. A dissecção arterial é a ruptura da sua parede com formação de hematoma intramural. Podem ser espontâneas, acometendo a artéria vertebral extra ou intracraniana. O tratamento em geral é clínico, porém em alguns casos está indicada intervenção. A via endovascular é uma importante alternativa, permitindo o tratamento específico da lesão em alguns casos, mas na maioria sacrificando a artéria vertebral, após teste de tolerância à oclusão. Com o objetivo de analisar os aspectos clínicos e técnicos do tratamento endovascular, estudamos de forma prospectiva 15 pacientes. Três apresentavam dissecções traumáticas (todas extracranianas) e 12 espontâneas, dos quais dois tiveram traumatismos menores como desencadeantes. Cinco pacientes apresentaram dissecções extracranianas, oito, intracranianas e dois, combinadas. No grupo das extracranianas, a principal indicação de tratamento foi a presença de fístula arteriovenosa, em três dos cinco pacientes. No grupo da intracranianas, foi a presença de hemorragia meníngea. Nos quatro pacientes com acidente vascular isquêmico, a indicação de tratamento deveu-se à presença de pseudoaneurismas que não involuíram com tratamento clínico. Nesse grupo, dois pacientes tinham dissecção extracraniana, um, intra e um, combinada. Um paciente apresentou intolerância à oclusão e foi encaminhado para tratamento conservador. Dos 14 pacientes tratados, um teve como estratégia a oclusão seletiva da lesão, 11 a oclusão da artéria vertebral proximal à lesão e dois oclusão acima e abaixo da lesão. Os materiais utilizados foram balões destacáveis em sete pacientes, molas de destaque livre em 6 e molas eletricamente destacáveis associadas a molas de destaque livre em 1 paciente. Dois pacientes apresentaram complicações do tratamento, e um paciente, recidiva de fístula arteriovenosa, todos resolvidos sem seqüelas. A angiografia controle revelou oclusão total do segmento dissecado ou do pseudoaneurisma em 9 pacientes, reversão do fluxo em quatro e preservação da artéria vertebral com oclusão da lesão em um. Num período de seguimento de 8,6 meses não se registraram recorrências. O tratamento foi eficiente na prevenção de ressangramentos e na trombose dos pseudoaneurismas e apresenta segurança em relação a complicações. / Vertebral artery dissections can cause brain ischemia and hemorrhage. Arterial dissection consist of mural tears with subsequent intramural hematoma formation. They may occur either spontaneously or as a consequence of traumatism, in the extracranial or intracranial vertebral artery. The treatment is usually clinical, but in some instances intervention is indicated. The endovascular approach is an important tool, allowing specific treatment of the lesion in some cases, but sacrificing the vertebral artery in most cases. With the aim of analyze the clinical and technical aspects of the endovascular treatment, we studied prospectively 15 patients treated by endovascular approach. Three presented traumatic dissections (all extracranial) and 12 spontaneous dissections, two of which after minor traumatic events. Five patients had extracranial dissections, eight, intracranial and two, combined. In the extracranial dissection group, the main indication for treatment was the presence of an arteriovenous fistula (three of five patients). In the intracranial group, it was subarachnoid hemorrhage. Four patients presenting with brain isquemia were treated because of pseudoaneurysms that did not resolve in clinical treatment. In this group 2 patients had extracranial dissections, one had intracranial and one had both. One patient did not tolerate occlusion and was treated clinically. Fourteen patients were treated by endovascular means, one with selective lesion occlusion, 12 with proximal vertebral artery occlusion and two with proximal and distal vertebral artery occlusion. The embolic material were detachable balloons in 7 patients, platinum microcoils in 6 patients and electrically detachable platinum microcoils and platinum microcoils in one patient. Two patients presented complications, and one presented recurrence of an arteriovenous fistula, all resolved without sequelae. Angiographic controls disclosed total occlusion of the segment with dissection or of the pseudoaneurysm in 9 patients, retrograde flow in 4 and vertebral artery preservation with selective lesion occlusion in 1. During a mean follow-up period of 8,6 months no recurrence was observed. The treatment was efficient in preventing recurrent hemorrhage and promoting pseudoaneurysms thrombosis, besides it was a safe treatment option.
97

Avaliação da perfusão miocárdia com estresse farmacológico no tomógrafo de 320 canais nos pacientes com bloqueio de ramo esquerdo em investigação de doença arterial coronariana / Evaluation of pharmacological stress myocardial perfusion tomography in 320 channels in patients with left bundle branch block in the investigation of coronary artery disease

Cabeda, Estêvan Vieira 25 October 2013 (has links)
Introdução: A perfusão miocárdica de estresse pela tomografia (PMT) é um método emergente e não-invasivo para detecção de isquemia miocárdica. O objetivo deste estudo foi avaliar a acurácia diagnóstica da PMT em pacientes com bloqueio de ramo esquerdo (BRE) que estavam em pesquisa diagnóstica de doença arterial coronariana (DAC) e o valor adicional da PMT sobre a tomografia computadorizada com múltiplos detectores (ATC) usando tomógrafo com 320 detectores, e compará-los com a cintilografia de perfusão miocárdica (SPECT) para detecção de isquemia miocárdica com estenose coronariana significativa (estenose >- 70%), utilizando a angiografia coronariana quantitativa (QCA) e a angiografia coronariana pela tomografia computadorizada com múltiplos detectores como referências. Material e Métodos: Quarenta e dois pacientes com BRE e SPECT ( < 2 meses) em avaliação diagnóstica de DAC foram encaminhados para realizar o protocolo de tomografia que incluiu o escore de cálcio, PMT, ATC e realce tardio do miocárdio. Trinta pacientes foram encaminhados para angiografia coronária invasiva. As imagens foram interpretadas por observadores independentes e alheios aos resultados dos exames e aos dados clínicos. Foram realizadas análises por paciente e por território. O estudo obteve a aprovação da comissão de ética e todos os pacientes assinaram consentimento informado. Resultados: A idade média dos pacientes foi 63 +- 10 anos e, destes, 67% mulheres (28 pacientes). A dose média de radiação total foi de 9,3 +- 4,6 mSv. Na análise por paciente, sensibilidade, especificidade, valores preditivos positivo e negativo foram de 86%, 89%, 80 e 93% para a PMT (p=0,001) (kappa 0,74) e 63%, 91%, 65% e 90% (p < 0,001) na análise por território (kappa 0,55), respectivamente. Em ambas as análises, o ATC mostrou excelente precisão, com área sob a curva ROC=0,9. Considerável concordância foi demonstrada entre SPECT e o QCA (kappa 0,32 e 0,26) nas análises por paciente e por território, respectivamente. A avaliação combinada da ATC com a PMT permitiu melhorar a acurácia diagnóstica para detecção de estenose coronariana com redução luminal hemodinamicamente significativa ( >= 70%) comparando-se com a ATC, PMT ou SPECT isolados, demonstrado por valores de sensibilidade, especificidade, e valores preditivos positivos e negativos de 93%, 87%, 87%, 93% (p < 0,0001) na avaliação combinada por paciente, e 85%, 90%, 79%, 93% (p < 0,0001) na avaliação combinada por território. Conclusão: O uso do protocolo tomográfico de estresse é viável e possui boa acurácia para diagnóstico de DAC em pacientes com BRE com resultados superiores ao SPECT. A combinação da PMT e ATC permitiu melhorar a acurácia diagnóstica da avaliação de obstrução coronariana significativa em pacientes com BRE / Introduction: Stress computed tomography myocardial perfusion (CTP) is an emerging and non-invasive method to detect myocardial ischemia. The objective of this study was to evaluate diagnostic accuracy of CTP in patients with left bundle branch block (LBBB) who were being evaluated for coronary artery disease (CAD) and the additional value of CTP on computed tomography angiography (CTA) using 320-row detector CT scanner and compare them with single-photon emission computed tomography (SPECT) for detection of myocardial ischemia with significant coronary stenosis >= 70% using quantitative invasive coronary angiography (QCA) and coronary CT angiography as references. Material and Methods: Forty two LBBB patients with SPECT ( < 2 months) in diagnostic evaluation for CAD were referred to stress CT protocol which included calcium score, CTP, CTA and myocardial delayed enhancement. Thirty patients were referred to invasive coronary angiography. Independent blinded observers performed analyses of the images. Per-patient and perterritory analyses were conducted. Ethical committee aproval was obtained and all patients gave informed consent. Results: The mean age was 63 +- 10 years. 67% were women (28 patients). The total mean radiation dose was 9,3 +- 4,6 mSv. In per-patient sensitivity, specificity, positive and negative values were 86%, 89%, 80 and 93%, for CTP (p=0,001) (kappa 0.74) and 63%, 91% 65% and 90% (p < 0,001) in per-territory analysis (kappa 0.55), respectively. In both analyses, CTA showed excellent accuracy with area under receiver operating curve (AUC) = 0.9. Fair agreement was demonstrated between SPECT and QCA (kappa 0,32 e 0,26) in per-patient and per-territory analyses, respectively. The combined analysis of CTA with CTP, improved diagnostic accuracy for detection of coronary stenosis with hemodynamically significant luminal reduction ( >= 70%) compared with CTA, CTP or SPECT alone, demonstrated by sensitivity, specificity, and positive and negative predictive values of 93%, 87%, 87%, 93% (p < 0,0001) in the combined evaluation by patient and 85%, 90%, 79%, 93% (p < 0,0001) in the combined evaluation by territory. Conclusion: The use of customized stress CT protocol is feasible and has good accuracy for the diagnosis of CAD in patients with LBBB with results better than SPECT. The combination of PMT and ATC has improved the diagnostic accuracy of the assessment of significant coronary obstruction in patients with LBBB
98

Estudo comparativo entre ultra-sonografia com Doppler colorido, angiografia por ressonância magnética, por subtração digital 2D e 3D na doença dos vasos carotídeos cervicais / A comparative study of Doppler ultrasound, magnetic resonance angiography, 2D and 3D digital subtraction angiography in cervical carotid stenoocclusive disease

Barros, Cristiano Ventorim de 02 October 2009 (has links)
INTRODUÇÃO: Os métodos diagnósticos não invasivos, como a ultra-sonografia com Doppler colorido (USDC) e a angiografia por ressonância magnética contrastada (ARMC) têm sido cada vez mais utilizados para o estudo da estenose das artérias carótidas internas (ACI). Nos testes comparativos a arteriografia por subtração digital bidimensional (ASD 2D) tem sido o padrão de referência, porém é um método caro, invasivo e com diversas complicações descritas, além disso, com a realização da arteriografia por subtração digital rotacional (ASD 3D), começou a se interrogar se a ASD 2D não estaria subestimando as estenoses. OBJETIVOS: Comparar as medidas de estenose obtidas pelos métodos não invasivos com a ASD 2D e 3D, utilizando o critério do North American Symptomatic Carotid Endarterectomy Trial (NASCET), além de comparar os dois métodos invasivos entre si, tentando identificar se os métodos não invasivos podem substituir a ASD 2D na rotina e se a ASD 2D tende subestimar a estenose em relação a ASD 3D. MÉTODOS: 92 pacientes que haviam sido indicados de maneira prospectiva e consecutiva para realização da ASD 2D, foram selecionados para o estudo, sendo encaminhados para realizar também a ASD 3D, a ARMC e o USDC. Os resultados das medidas da maior estenose, realizadas através das imagens fonte em estação de trabalho, por dois observadores em consenso, obtidas em cada um dos testes (USDC, ARMC) e dos resultados concordantes dos dois, foi comparada com os exames de referência (ASD 2D e ASD 3D). Foi feita também uma avaliação dos resultados dos exames invasivos entre si. RESULTADOS: 98 ACI foram incluídas no trabalho. Os resultados obtidos pelo coeficiente de correlação de Pearson e pelo coeficiente de correlação intraclasse, que variaram de 0,91 a 0,96, demonstraram respectivamente uma excelente correlação entre as modalidades diagnósticas e que há uma forte concordância entre os seus resultados (ambos com p <0,001). Os valores de sensibilidade, especificidade, valor preditivo positivo, valor preditivo negativo e acurácia das diversas comparações variaram respectivamente de 76 a 100%, de 92 a 100%, 79 a 100%, 90 a 100% e 90 a 100%. DISCUSSÃO: As comparações com maior sensibilidade, especificidade e acurácia foram respectivamente a (USDC+ARMC) x ASD 3D com 100%, 100% e 100%; ARMC x ASD 3D com 100%, 96% e 97% e ASD 2D x ASD 3D, com 89%, 94% e 93%. A ASD 2D categorizou as estenoses em 11 casos (11,3%) uma classe abaixo das obtidas na ASD 3D, além de classificar 4 estenoses a menos que a ASD 3D na classe de 70-94%. CONCLUSÕES: Os métodos não invasivos principalmente se avaliados em conjunto podem substituir a ASD 2D na avaliação da estenose da ACI. A ASD 2D tendeu a subestimar levemente as estenoses quando comparada com a ASD 3D / INTRODUCTION: Noninvasive techniques such as Doppler ultrasound (DUS) and contrast enhanced magnetic resonance angiography (CEMRA) are each day more used in the evaluation of the internal carotid arteries (ICA). On comparison studies 2D digital subtraction angiography (2D DSA) has been considerate as the reference standard, however its an expensive and invasive method, with well known risks, besides the use of 3D digital subtraction angiography (3D DSA) showed that 2D DSA can potentially result in an underestimation of the stenosis. OBJECTIVES: Compare stenosis measurements of noninvasive methods with 2D and 3D DSA, using the North American Symptomatic Carotid Endarterectomy Trial (NASCET) criteria, compare the two noninvasive methods with each other, trying to identify if they can substitute 2D DSA on the daily basis and if that 2D DSA tends to underestimate the stenosis compared with 3D DSA. METHODS: 92 patients that were prospective and consecutive scheduled for 2D DSA were selected to participate in the study which included perform also a 3D DSA, CEMRA and DUS. The measurements of the greatest stenosis, made with the raw images in a workstation, by two observers in consensus, obtained with each modality (DUS, CEMRA) and the concordant results of both, were compared with the reference standard (2D and 3D DSA). Also a comparison between the invasive methods was made. RESULTS: 98 ICA were included. The results obtained by Pearson correlation coefficient and intraclass correlation coefficient, that range from 0.91 and 0.96, showed respectively a excellent correlation between the diagnostic modalities and that there are a great agreement between them (both with p<0.001). Sensitivity, specificity, positive and negative predictive values, and accuracy values of the different comparisons range respectively from 76% to 100%, 92 to 100%, 79 to 100%, 90 to 100% and 90 to 100%. DISCUSSION: Comparisons with higher sensitivity, specificity and accuracy were respectively (DUS+CEMRA) x 3D DSA, with 100%, 100% and 100%; CEMRA x 3D DSA with 100%, 96% and 97% and 2D DSA x 3D DSA with 89%, 94% and 93%. 2D DSA categorized 11 cases (11,3%) of ICA stenosis as one category lower than 3D DSA, including 4 less cases of the 70-94% class. CONCLUSIONS: The noninvasive methods, especially if evaluated together, can replace 2D DSA in the study of cervical carotid steno-occlusive disease. 2D DSA tends to lightly underestimate carotid stenosis when compared to 3D DSA
99

Estudo de perfusão e viabilidade miocárdicas por ressonância magnética em pacientes com doença renal crônica candidatos a transplante renal / Assessment of myocardial perfusion and viability using cardiovascular magnetic resonance in patients with end-stage renal disease

Andrade, Joalbo Matos de 22 August 2006 (has links)
INTRODUÇÃO: A incidência de doença arterial coronária em candidatos a transplante renal é alta, sendo a principal causa de mortes neste grupo de pacientes. Os resultados obtidos com exames não invasivos usados na detecção de doença arterial coronariana destes pacientes têm-se mostrado variados e, de modo geral, insatisfatórios para uma condição clínica considerada grave. A ressonância magnética cardiovascular é utilizada cada vez mais no estudo de doença arterial coronária na população geral, apresentando bons resultados na identificação de isquemia e de fibrose miocárdica. Entretanto, este método, até o momento, não foi avaliado neste grupo de pacientes. O objetivo deste trabalho é avaliar a capacidade da ressonância magnética cardíaca em detectar doença arterial coronária em candidatos a transplante renal sob dois diferentes aspectos: diagnóstico de lesão coronariana significativa (redução do diâmetro luminal maior ou igual a 70%), avaliada pela alteração da perfusão miocárdica, comparando os resultados com a cintilografia e tendo a angiografia coronária como padrão de referência; e detecção de infarto miocárdico silencioso, comparando com a eletrocardiografia e cintilografia, tendo a ressonância magnética cardiovascular com a técnica de realce tardio como padrão de referência. MÉTODOS: Durante o período de janeiro de 2002 e janeiro de 2004 foram estudados 80 candidatos a transplante renal que apresentavam ao menos um dos seguintes critérios de inclusão: 1. idade igual ou acima de 50 anos; 2. diabete melito; 3. história ou evidência clínica de doença cardiovascular. Todos os pacientes foram encaminhados para serem submetidos a exames de eletrocardiografia, cintilografia, ressonância magnética cardiovascular e angiografia coronária no período máximo de até um ano entre os exames. Na pesquisa de alteração da perfusão miocárdica, comparou-se ressonância magnética cardiovascular com cintilografia em 76 pacientes, tendo a angiografia coronária como padrão de referência na identificação de lesão coronária significativa (estenose igual ou maior que 70% da luz vascular). Na identificação de infarto miocárdico silencioso, comparou-se a ressonância magnética cardiovascular com a eletrocardiografia e cintilografia em 69 pacientes. Os exames foram analisados de modo cego em relação aos resultados dos demais exames. Dados numéricos foram expressos como média, desvio padrão e intervalo de confiança, sendo calculado grau de concordância, testes diagnóstico e de significância entre os métodos. RESULTADOS: Na pesquisa de obstrução coronária significativa, a ressonância magnética cardiovascular apresentou sensibilidade, especificidade e acurácia de 84,1%, 56,3% e 72,4% e a cintilografia miocárdica 65,9%, 68,6% e 67,1%, respectivamente. A ressonância magnética cardiovascular foi significativamente mais sensível que a cintilografia (p=0,039). Na identificação de infarto miocárdico silencioso, o grau de concordância entre a ressonância magnética cardiovascular e o eletrocardiograma foi de 0,28 e entre a ressonância magnética cardiovascular e a cintilografia 0,52. Considerando-se a ressonância magnética cardiovascular como sendo o padrão de referência na identificação de infarto miocárdico silencioso, a sensibilidade, especificidade e acurácia do eletrocardiograma foram de 27,8%, 98% e 79,7% e da cintilografia foram de 66,7%, 87% e 81,2%, respectivamente. CONCLUSÃO: No diagnóstico de lesão coronariana significativa, a ressonância magnética cardiovascular mostrou acurácia similar e maior sensibilidade em relação à cintilografia. Na detecção de infarto miocárdico silencioso, o eletrocardiograma e a cintilografia apresentaram baixa concordância com a ressonância magnética cardiovascular / INTRODUCTION: Coronary artery disease in renal transplant candidates is frequent and is the most common cause of death. Results of standard noninvasive tests for the detection of coronary artery disease in this specific group are incosistent and, overall, considered inadequate for clinical decision making. Cardiovascular magnetic resonance has been used most frequently in the identification of coronary artery disease in the general population with good results in the analysis of myocardial ischemia and fibrosis. However, this method, until now, has not been evaluated for the diagnosis of coronary artery disease in renal transplant candidates. The goal of this study is to assess the capability of cardiovascular magnetic resonance for the detection of coronary artery disease in renal transplant candidates in two different aspects: the diagnosis of significant coronary stenosis (70% or more luminal diameter reduction) assessed by myocardial perfusion abnormalities, comparing the results with scintigraphy and using coronary angiography as the reference method; and the identification of unrecognized myocardial infarction, comparing with electrocardiography and nuclear medicine, using cardiovascular magnetic resonance late enhancement technique as the reference method. METHODS: Between January 2002 and January 2004 we studied 80 renal transplant candidates with at least one of these inclusion criteria: 1. 50 years of age or more, 2. diabetes mellitus, and 3. clinical history or evidence of coronary artery disease. All patients underwent electrocardiogram, nuclear medicine, cardiovascular magnetic resonance and coronary angiography examinations within a maximum period of one year. In the assessment of myocardial perfusion defect, we compared cardiovascular magnetic resonance with scintigraphy in 76 patients with coronary angiography as the reference method in the identification of significant coronary lesion (70% stenosis of the vascular lumen or more). In the identification of unrecognized myocardial infarction, we compared magnetic resonance with electrocardiogram and nuclear medicine in 69 patients. All exams were reviewed by readers blinded to the results of the other exams. Data was presented as mean, standard deviation and confidence interval. Percentual of agreement, diagnostic tests and statistical tests between the exams were calculated. RESULTS: On the assessment of significant coronary stenosis, cardiovascular magnetic resonance showed sensitivity, specificity and accuracy of 84.1%, 56.3%, and 72.4% and nuclear medicine 65.9%, 68.6%, and 67.1%, respectively. Cardiovascular magnetic resonance was significantly more sensitive than scintigraphy medicine (p=0.039). In the identification of unrecognized myocardial infarction, agreement between cardiovascular magnetic resonance and electrocardiogram was 0.28 and between cardiovascular magnetic resonance and scintigraphy was 0.52. Considering cardiovascular magnetic resonance as the reference method in the identification of unrecognized myocardial infarction, the sensitivity, specificity and accuracy of the electrocardiogram were 27.8%, 98% and 79.7%, and for scintigraphy were 66.7%, 87% and 81.2%, respectively. CONCLUSION: In the diagnosis of significant coronary stenosis, cardiovascular magnetic resonance showed similar accuracy and higher sensitivity compared to scintigraphy. In the detection of unrecognized myocardial infarction, the electrocardiogram and scintigraphy presented low agreement with cardiovascular magnetic resonance
100

Integração do estudo anatômico coronariano através da angiotomografia/escore de cálcio ao estudo funcional de perfusão miocárdica pelo PET-CT utilizando rubídio na investigação da doença arterial coronariana / Integration of the coronary anatomy study through angiotomography/coronary artery calcium score to the functional study of myocardial perfusion by PET-CT using rubidium in the investigation of coronary artery disease

Fahel, Mateus Guimarães 20 October 2017 (has links)
Introdução: A doença arterial coronariana (DAC) persiste com alta morbimortalidade. Várias modalidades diagnósticas não-invasivas estão disponíveis para sua avaliação, incluindo escore de cálcio coronariano (EC), angiotomografia coronariana (AngioTC) e tomografia por emissão de pósitrons com rubídio (PET-CT82Rb), com ótimas sensibilidade e especificidade. A integração destes métodos em um exame híbrido permite delinear extensão anatômica e funcional da aterosclerose, possibilitando diagnósticos mais corretos. Objetivo: Avaliar anatomia coronariana e perfusão miocárdica de pacientes suspeitos ou portadores de DAC com tecnologia híbrida (PETCT82Rb e AngioTC/EC), testando a hipótese da maior acurácia do método híbrido em relação aos métodos isolados, correlacionando com desfecho de IAM/óbito cardíaco após 24 meses. Métodos: Foram incluídos 54 pacientes dos ambulatórios de cardiologia do Instituto do Coração (InCor-HCFMUSP), que realizaram estudo híbrido no departamento de Medicina Nuclear do InCor entre maio e outubro de 2013. A carga aterosclerótica coronariana foi contabilizada pelo escore de cálcio; a quantidade de lesões coronarianas, o grau de redução luminal e a composição das placas foram avaliados através da AngioTC; isquemia/fibrose pelo PET-CT82Rb foi contabilizada através do SDS (summed difference score) do estresse e repouso e a reserva de fluxo coronariana (RFC) foi considerada reduzida quando menor que 2mL/min/g. Após 24 meses, foi realizado contato telefônico e avaliação do prontuário dos pacientes, sendo pesquisado infarto agudo do miocárdio/óbito cardíaco como desfecho clínico principal. Resultados: Dentre os participantes, houve predomínio de homens (61,3%), com idade média de 55,5 ± 12,3 anos. A maioria apresentava sobrepeso/obesidade (76%), hipertensão arterial sistêmica (70,4%) e/ou dislipidemia (61,1%). O protocolo durou uma média de 52,2 ± 3,5 min e a dose total média de radiação foi 12,29 ± 2,88 mSv. A média do EC total foi 127,3 ± 249,0, sendo que 24% da amostra possuíam EC maior que 100. Houve predomínio de placas de ateroma mistas (51,3%), com 13% dos pacientes apresentando lesões angiograficamente significativas ( >= 50%). Oito pacientes apresentaram resultado alterado na análise perfusional qualitativa/semiquantitativa (14,8%), metade com isquemia e metade com fibrose. A RFC estava reduzida globalmente em 18,5% dos pacientes e de forma segmentar em 5,6%. Após 24 meses, 9,3% dos pacientes apresentaram infarto, 60% destes fatais. Houve concordância no máximo moderada dos métodos avaliados com a RFC (Kappa = 0,514; p= 0,001). Quanto ao desempenho dos métodos para ocorrência de IAM em 24 meses, foi demonstrada elevada acurácia da RFC para tal finalidade, com AUROC de 0,963 (IC95% 0,912 - 1,000; p= 0,001), com melhor ponto de corte de 1,975 mL/min/g. Não foi identificada alteração na sensibilidade ou no valor preditivo negativo quando a RFC foi agregada aos outros métodos, inclusive houve redução do valor preditivo positivo e da especificidade em relação à RFC isoladamente. Conclusão: O método híbrido não apresentou maior acurácia que a RFC pelo PET-CT82Rb isoladamente na predição de IAM em dois anos de acompanhamento, todavia, a tomografia cardíaca agrega informações importantes capazes de influenciar a conduta clínica nos pacientes não isquêmicos e possivelmente modifica desfechos em médio/longo prazo / Introduction: Coronary artery disease (CAD) persists with high morbidity and mortality. Several non-invasive diagnostic imaging modalities are available for its evaluation, including coronary calcium score (CS), coronary CT angiography (AngioCT) and positron emission tomography with rubidium (82Rb PET-CT), with excellent sensitivity and specificity. The integration of these methods into a hybrid examination allows delineating the anatomical and functional impact of atherosclerosis, enabling more accurate diagnoses. Objective: To evaluate coronary anatomy and myocardial perfusion of patients with suspected or known CAD with hybrid technology (82Rb PET-CT and AngioCT/CS), testing the hypothesis of the greater accuracy of the hybrid method in relation to the isolated methods, correlating with myocardial infarction/cardiac death outcome after 24 months. Methods: Fifty-four consecutive patients referred from the Cardiology outpatient clinics of the Heart Institute (InCor-HCFMUSP) to perform CAD assessment in a hybrid study in the Department of Nuclear Medicine of InCor, between May and October 2013, were enrolled. The coronary atherosclerotic burden was accounted by CS; the amount of coronary lesions, stenosis severity and plaque composition were evaluated through AngioCT; 82Rb PET-CT perfusional analysis was evaluated through the rest and dipyridamole stress summed difference score (SDS) and the coronary flow reserve (CFR) was considered impaired when < 2mL/min/g. After 24 months, the composite outcome of myocardial infarction and cardiac death was evaluated through telephone contact and patient\'s medical records. Results: From the 54 enrolled patients, mean age was 55.5 ± 12.3 years and 61% were male. Most patients presented overwheight/obesity (76%), systemic arterial hypertension (70%) and/or dyslipidemia (61%). The protocol lasted an average of 52.2 ± 3,5 min and mean radiation dose was 12.29 ± 2,88 mSv. The mean total CS was 127.3 ± 249.0, and 24% of the patients were above 100. There was a predominance of patients with mixed atheroma plaques (51.3%) and 13% presented angiographically significant lesions ( >= 50%). Eight patients presented perfusion impairment in the qualitative/semi-quantitative perfusion analysis (14.8%), half with ischemia and half with fibrosis. The CFR was globally reduced in 18.5% of the sample and in a segmental manner in 5.6%. After 24 months of follow-up, 9.3% of the patients had a myocardium infarction, 60% of these were fatal. A maximum of moderate agreement was found between the methods and CFR (Kappa = 0.514, p= 0.001). Regarding the performance of the different methods for predicting infarction in 24 months, CFR reached high accuracy, with AUROC of 0.963 (95% CI 0.912 - 1.0; p= 0.001), with a cutoff point of 1.975 mL/min/g. No variation in neither sensitivity nor negative predictive value was identified when the other methods were added to CFR, instead, there was a reduction in positive predictive value and specificity in relation to unaided CFR. Conclusion: There was no incremental value of the hybrid method when compared to isolated CFR 82Rb PET-CT for the prediction of myocardial infarction in two years follow-up. However, cardiac CT aggregates important information capable of influencing clinical management of nonischemic patients and possibly modifies medium/long-term cardiac outcomes

Page generated in 0.0314 seconds